DIMENSIONS SETTING The three-step setup procedure adjusts the sensor sensitivity and sets the LIGHT/DARK mode. The procedure given below describes a LIGHT mode setting for proximity fibres and a DARK mode setting for emitter/receiver fibres. Connecting the REMOTE input to the +Vdc supply is equivalent to pressing the pushbutton. The control protection transparent cover can be removed by gently pulling it while it is completely open. Fixing holes O-Ring (A) Fibre-optic Not used Receiver Output saturation voltage: Response time: Timing function (TIMER): Indicators: Fibres insertion holes Fibre-optics installation: Press the lock button and keep it pressed until all the fibres are completely inserted. Insert the emission fibre in the hole corresponding to the desired emission (red or green). The first insertion resistance is due to the O-ring seal; please continue to insert the fibres for about 6 mm until it touches the photoelectric components (A). CONNECTIONS BLACK 10 … 26.4 Vdc OUTPUT GREY TIMER WHITE REMOTE RED TEN-3-x 4 WIRE CABLE BROWN + BLACK 10 … 26.4 Vdc OUTPUT WHITE REMOTE BLUE 0V ALARM BLUE Setting: Retention data: Operating temperature: Storage temperature: Electric shock protection: Operating distance (RED/GREEN emission): Emission type: Ambient light rejection: Vibration: Shock resistance: Housing: Protection class: Connections: 0V Weight: TEN-5-x M8 CONN. TIMER OUTPUT (WHITE) (BLACK) 2 + 1 10 … 26.4 Vdc (BROWN) 4 3- 0V (BLUE) TEN-6-x M8 CONN. REMOTE (WHITE) 2 + 1 10 … 26.4 Vdc (BROWN) 9 25 press the SET pushbutton and keep it pressed until the green LED flashes. Don’t move the target during this phase. SET PUSHBUTTON TEN-2-x Lock button Lock button + mm SET LED 12.0 Fix the sensor using the DIN guide or through the fixing holes. BROWN 2) Output ON state acquisition Proximity fibres: place the target opposite the sensor at the maximum distance required; Emit./Rec. fibres: place the target between the fibre tips; 3) output OFF state acquisition Proximity fibres: place no target; Emit./Rec. fibres: place no target; TECHNICAL DATA Power supply: Ripple: Current consumption (output current excluded): Output: Main output current: ALARM output current: INSTALLATION TEN-2-x 6 WIRE CABLE 25.4 34.25 OUTPUT LED SET PUSHBUTTON The pushbutton activates the setup procedure. DIN guide 25.0 21.75 TIMER LED SET LED (bi-colour) During functioning, the green or orange LED ON indicates a normal operating condition; red blinking indicates an output overload condition. See the “SETTING” paragraph for setup procedure indications. Emitter - green LED (TEN-2/5-x) Emitter - red LED press the SET pushbutton and keep it pressed until the SET LED flashes orange. The flashing rate vares according is are operating conditions; high flashing rate indicates insufficient received signal level or excessive distance: improve alignment or reduce the distance to obtain a low flashing rate. The SET LED flashing is replicated by the sensor emission and is visible at the fibre tips. 1.5 CONTROLS OUTPUT LED The yellow LED indicates that the output status. place the target opposite the fibre tips at the maximum distance required; Emit./Rec. fibres: position the fibre tips on opposite sides; 3.5 12.0 TIMER LED (TEN-2/5-x) The green led indicates that the timer is ON. 1) Alignment Proximity fibres: 17 39.5 6.3 26.5 INSTRUCTION MANUAL 44.5 TEN SERIES 8.0 64.0 OUTPUT TEN-5-x TEN-3-x press the SET pushbutton and keep it pressed until the SET LED lights permanently ON; this means that the procedure has been completed successfully, and a low contrast (LED ON in orange) or high contrast (LED ON in green) was detected. If the SET LED flashes alternately red and green the setup procedure has failed due to insufficient contrast; repeat the procedure from the beginning. TEN-6-x 10 … 26.4 Vdc limit values; reverse polarity protection 2 Vpp max. 60 mA 55 mA To set the fibre in DARK mode with proximity fibres and in LIGHT mode with emitter/receiver fibres invert the 2 and 3 steps. NPN (TEN-x-N) or PNP (TEN-x-P); 30 Vdc max. 100 mA max. (short-circuit protection) 20 mA without protection ALARM FUNCTION (TEN-2-x) - 1 V max. NPN versions / 2V max. PNP versions 100 s 333 s 40 ms minimum output ON OUTPUT LED (YELLOW) OUTPUT LED (YELLOW) TIMER LED (GREEN) SET LED (RED/GREEN) SET LED (RED/GREEN) SET pushbutton SET pushbutton SET pushbutton and REMOTE wire and REMOTE wire non volatile EEPROM memory -10 … 55 °C -25 … 70 °C Class 2 with (OF-18): 0 … 6 mm (green emission) 0 … 45 mm (red emission) with (OF-18): 0 … 75 mm (red emission) with (OF-19): 0 … 25 mm (green emission) with (OF-19): 0 … 300 mm (red emission) 0 … 180 mm (red emission) selectable by choosing RED (630 nm) GREEN (565 nm) or RED (630 nm) according to EN 60947-5-2 0.5 mm amplitude, 10 … 55 Hz frequency, for every axis (EN60068-2-6) 11 ms (30 G) 6 shock for every axis (EN60068-2-27) Polycarbonate IP65 6 wires 2 m cable M8 4-pole 6 wires 2 m cable M8 4-pole connector connector 4.5 mm 4.5 mm 115 g. max. cable versions / 30 g. max. connector versions The ALARM output switches ON when the main output is overloaded and returns OFF when the overloaded is removed. This output is NPN type for TEN-2-N and PNP type for TEN-2-P, maximum current 20 mA without short circuit protection. DECLARATION OF CONFORMITY We DATALOGIC AUTOMATION declare under our sole responsibility that these products are conform to the 2004/108/CE and successive amendments. WARRANTY DATALOGIC AUTOMATION warrants its products to be free from defects. DATALOGIC AUTOMATION will repair or replace, free of charge, any product found to be defective during the warranty period of 36 months from the manufacturing date. This warranty does not cover damage or liability deriving from the improper application of DATALOGIC AUTOMATION products. DATALOGIC AUTOMATION Via Lavino 265 - 40050 Monte S.Pietro - Bologna – Italy Tel: +39 051 6765611 - Fax: +39 051 6759324 www.automation.datalogic.com e-mail:info.automation.it@datalogic.com TIMING FUNCTION (TEN-2/5-x) DATALOGIC AUTOMATION cares for the environment: 100% recycled paper. DATALOGIC AUTOMATION reserves the right to make modifications and improvements without prior notification. (BLACK) 4 3- 0V (BLUE) A delay function TIMER is available which extends the minimum ON output time to 40 ms (see figure aside). The TIMER enable wire must be connected to +Vdc before powering the sensor to enable the delay function. ON ON OUT without TIMER OFF OFF ON ON OUT with TIMER 40 ms OFF 40 ms OFF Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. 826000255 Rev.F © Copyright Datalogic 2007-2010