NCLR CLASS RK1 FAST-ACTING FUSES SCLR CLASS RK1 FAST-ACTING FUSES Catalog Number NCLR (1 - 600A) 250 Volts AC or Less Catalog Number SCLR (1 - 600A) 600 Volts AC or Less 1 3 4 5 6 8 10 12 15 20 25 30 1 2 3 4 5 6 8 10 12 15 20 25 AMPERE RATINGS NCLR 250V 35 80 40 90 45 100 50 110 60 125 70 150 SCLR 600V 30 70 35 80 40 90 45 100 50 110 60 125 NCLR/SCLR SPECIFICATIONS Fast-Acting 175 200 225 250 300 350 400 450 500 600 — — 150 175 200 225 250 300 350 400 450 500 600 — BENEFITS: • No intentional time-delay; opens quickly on overload current. • Extremely current limiting silver link construction; provides superior component circuit protection. APPLICATIONS: • Recommended for protection on non-inductive loads such as lighting and resistance heating circuits. • Use to protect lower interrupting rating circuit breakers in series rated applications. Voltage Rating: NCLR - 250VAC, SCLR - 600VAC Ampere Rating: 1 - 600 Amps Interrupting Rating: 200,000 RMS Symmetrical Amps Current Limiting: RK1 Fuse Agency Approvals: UL Listed, Class RK1, Guide JDDZ, File E162363 CSA Certified HRCI-R per C22.2, No. 248.12 Self-Certified DC Ratings: Voltage Rating: NCLR (1-600) 250VDC SCLR (1-600) 300VDC Interrupting Rating: NCLR/SCLR 10,000 Amperes DC RECOMMENDED FUSEBLOCKS: Refer to page 136 in this catalog. RECOMMENDED UPGRADE: LENRK/LESRK. VOLTS 250 600 EDISON NCLR SCLR CROSS REFERENCE BUSSMANN GOULD KTN-R A2KR KTS-R A6KR* LITTELFUSE KLNR KLSR* * Larger body size on blade type. 11 NCLR CLASS RK1 FAST-ACTING FUSES SCLR CLASS RK 1 FAST-ACTING FUSES Application: Edison NCLR/SCLR Class RK1 fast acting fuses are recommended for general power distribution system use for main, feeder and branch circuits having a high percentage of noninductive loads such as heating and lighting. NCLR/SCLR fuses are suitable for circuit breaker protection.* When NCLR/SCLR fast acting fuses are used for inductive loads, the fuses usually require oversizing to override normal transient current surges of motors and transformers. Oversizing fuses usually increases fuse and equipment cost and reduces overcurrent protection. (For inductive loads, LENRK/LESRK fuses are recommended). NCLR/SCLR Class RK1 fast acting fuses are physically interchangeable with other Class R fuses. They will replace Class K or Class H fuses in standard fuse clips. *When used as recommended by a specific circuit breaker manufacturer for a specific application. AVERAGE TIME/CURRENT CURVE 400A 600A 600 800 1,000 200A 100A 60A 30A Cat. No. NCLR (Amp) 250V and SCLR (Amp) 600V AMPERE RATING 300 200 100 80 60 40 30 20 10 8 6 TIME IN SECONDS 4 3 2 1 .8 .6 .4 .3 .2 .1 .08 .06 .04 .03 .02 RMS SYMMETRICAL CURRENT IN AMPERES 12 8,000 10,000 6,000 4,000 3,000 2,000 400 300 200 80 100 60 40 .01 NCLR CLASS RK1 FAST-ACTING FUSES SCLR CLASS RK1 FAST-ACTING FUSES PEAK LET-THROUGH CURRENT CURVES* NCLR (250V) SCLR (600V) B 400,000 30 3,000 A RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) AMPERE RATING 30 6,000 5,000 4,000 3,000 A 2,000 1,000 200,000 80,000 100,000 40,000 50,000 60,000 30,000 20,000 8,000 10,000 4,000 5,000 6,000 3,000 2,000 2,000 60 8,000 200,000 6,000 5,000 4,000 10,000 80,000 100,000 60 8,000 100 40,000 50,000 60,000 10,000 200 20,000 30,000 100 30,000 20,000 200 20,000 8,000 10,000 30,000 400 4,000 5,000 6,000 400 600 60,000 50,000 40,000 3,000 600 60,000 50,000 40,000 100,000 80,000 2,000 100,000 80,000 200,000 1,000 AMPERE RATING 200,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 300,000 1,000 INSTANTANEOUS PEAK LET-THRU CURRENT IN AMPS 300,000 1,000 B 400,000 RMS SYMMETRICAL CURRENTS IN AMPERES A–B=ASYMMETRICAL AVAILABLE PEAK (2.3 X SYMM RMS AMPS) *Curves test data obtained at 15% short-circuit power factor when possible. CURRENT LIMITATION TABLES** NCLR (250V) SCLR (600V) NCLR – RMS & Peak Let-Thru Currents (kA) SCLR – RMS & Peak Let-Thru Currents (kA) Prosp. Short C.C. 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 150,000 200,000 Fuse Size 30 IRMS Ip 1 2 1 2 1 3 1 3 1 3 1 3 1 3 1 3 2 4 2 4 2 4 2 4 2 4 2 4 2 5 2 5 60 IRMS 1 1 2 2 2 2 2 2 2 2 3 3 3 3 3 3 Ip 3 3 4 4 5 5 5 5 5 6 6 6 6 7 7 8 100 IRMS 2 2 2 3 3 3 3 3 4 4 4 4 5 5 5 6 Ip 4 5 6 6 7 7 8 8 9 9 9 10 10 11 13 14 200 IRMS 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 9 Ip 6 8 9 10 10 11 12 12 13 14 15 15 16 17 19 21 400 IRMS 5 6 7 8 9 10 10 10 11 12 13 13 13 14 16 18 Ip 10 14 17 19 20 22 23 24 26 28 29 30 31 32 37 41 600 IRMS 5 8 10 11 12 13 13 14 15 17 17 18 19 20 23 26 Ip 12 19 22 25 27 29 31 32 36 38 40 42 44 46 53 59 Prosp. Short C.C. 5,000 10,000 15,000 20,000 25,000 30,000 35,000 40,000 50,000 60,000 70,000 80,000 90,000 100,000 150,000 200,000 Fuse Size 30 IRMS Ip 1 2 1 2 1 3 1 3 1 3 1 3 2 4 2 4 2 4 2 4 2 4 2 4 2 5 2 5 2 5 3 6 60 IRMS 1 2 2 2 2 2 2 2 3 3 3 3 3 3 4 4 Ip 3 4 4 5 5 5 5 6 6 6 7 7 7 7 8 9 100 IRMS 2 2 3 3 3 3 4 4 4 4 5 5 5 5 6 7 Ip 4 5 6 7 7 8 8 9 9 10 10 11 12 12 14 15 200 IRMS 3 4 4 5 5 5 6 6 6 7 7 7 8 8 9 10 Ip 6 8 10 11 12 13 13 14 14 15 16 17 18 19 21 23 400 IRMS 5 7 8 9 10 10 11 11 12 13 14 14 15 16 18 20 Ip 12 15 18 20 22 24 25 26 28 30 32 33 35 36 41 46 600 IRMS 5 9 11 12 13 14 15 16 17 19 20 21 22 23 26 29 Ip 12 20 24 28 31 33 35 37 40 43 45 48 50 52 60 66 *"Apparent Let-Thru Amperes" values are read from "Peak Let-Through Current Curves" and the peak current value divided by 2.3 Asymmetry Factor. 13