Installation Quick Reference Mounting Network cable routed through a wall and the Backplate’s hole cutout. Network cable to speaker assembly 611051A/ 611052A 161019 (1X) 011098A/ 011099A Network cable 151020 (4X) 1. Use the template on the back of this document to drill four holes in the wall for the anchors and screws. 011108B*, RAL 9002, Gray White, Standard 011109B, RAL 9003, Signal White, Optional 2. Place the four Plastic Ribbed Anchors in the holes you prepared. 611054A/ 611055A 121001A Accessory Kit Wall Mount Adaptor for Indoor Paging Speakers To mount a Wall Mount Adapter: Install the grounding nut onto the Backplate’s ground lug. *Replaces the 010882 number. 3. Position the Backplate over the holes. The Wall Mount Adaptor for Indoor Paging Speakers is an adapter that is built for a CyberData Ceiling speaker. 4. Use the four #6 X 1.25-inch sheet metal screws to secure the Backplate. Wall Mount Adapter Parts 5. Install the IP Speaker Assembly onto the enclosure by aligning the three mounting holes with the mounting screws (#071005A or 071006A) that comes with the IP Speaker Assembly. (1) Wall Mount Adapter (1) Template for Wall Mount Adapter and Screw Holes* 6. Plug the Ethernet cable into the IP Speaker Assembly. The yellow light verifies the network connection. 071054A (4) #6 x 1.25-inch sheet metal screw (4) Plastic ribbed anchors (1) Enclosure Mounting Kit Note: Route the Ethernet cable through the Backplate or through the slots at the top of the enclosure and Backplate. 7. Install the enclosure with the IP Speaker Assembly over the Backplate and install the four enclosure mounting screws. (1) Drywall Mounting Kit (1) Grounding nut (4) Enclosure mounting screw *Note: the ceiling speaker wall-mounted adapter screws will be included in the ceiling speaker kit. *Install the grounding nut onto the Backplate’s ground lug. Overall Dimensions 3.97 [100.8] 12.05 [306.0] 10.00 [254.0] Contacting CyberData Corporate Headquarters CyberData Corporation 3 Justin Court Monterey, CA 93940, USA Phone: 831-373-2601 Fax: 831-373-4193 www.CyberData.net Sales: (831) 373-2601 ext. 334 Support: 831-373-2601 ext. 333 Web: http://www.cyberdata.net/support/contactsupportvoip.html RMA Dept: (831) 373-2601 ext. 136 Email: RMA@CyberData.net RMA Status: http://www.cyberdata.net/support/rmastatus.html Warranty information is available at: Web: http://www.cyberdata.net/support/warranty/index.html © 2011, CyberData Corporation, ALL RIGHTS RESERVED 930405A ENCLOSURE Quick Reference Quick Reference DIMENSIONS ARE IN INCHES [MILLIMETER]; PROJECTION: THIRD ANGLE 930405A BACKPLATE © 2011, CyberData Corporation, ALL RIGHTS RESERVED 10.00 [254.0] 930405A PRE-DRILL 4 X 0.1875" [4.8] HOLE FOR MOUNTING BACKPLATE CUT HOLE FOR NETWORK CABLE AND GROUND WIRE 8.00 [203.2] © 2011, CyberData Corporation, ALL RIGHTS RESERVED Quick Reference Quick Reference 930405A © 2011, CyberData Corporation, ALL RIGHTS RESERVED