Tools and Parts Required
To replace DC or AC power supplies, you need the following tools and parts:
Phillips (+) screwdrivers, numbers 1 and 2
ESD grounding wrist strap
7/16-in. nut driver or wrench for tightening nuts to grounding and terminal studs on a
DC power supply; if 7/16-in. tool is not available, use pliers or an adjustable wrench
rather than a metric nut driver or wrench
Maintain the Power Supplies
To maintain the power supplies, follow these guidelines:
Make sure that the power and ground cables on each DC power supply are arranged so
that they do not obstruct access to the other power supply or to the Routing Engine.
Routinely check the LEDs on the power supply faceplate. The green OK LED indicates
that the power supply is functioning normally; the red FAIL LED indicates a power supply
fault. For more information about the power supply LEDs, refer to “Power Supply LEDs”
on page 22.
Maintain and Replace the Power Supplies
135
Replace an A C Power Supply
Issue the following CLI command to check the status of the power supplies. As shown in
the sample output, the value OK in the Status column indicates that the power supply is
operating normally:
user@host> show chassis environment
Class Item
Power Power Supply A
Power Supply B
. . .
Status
OK
OK
Measurement
For further description of the output from the command, see the JUNOS Internet
Software Oper ational Mode Command R eference: Pr otocols, Class of Service , Chassis,
and Management .
Check the red and yellow alarm LEDs and the LCD on the craft interface. Power supply
failure or removal triggers an alarm that causes one or both of the LEDs to light and an
error message to appear on the LCD. You can display the error messages remotely by
issuing the following CLI command:
user@host> show chassis alarms
For a list of possible alarm messages, see “Hardware and Interface Alarm Messages” on
page 235.
Verify that the airflow to each supply is unobstructed.
Verify that the power source has the proper current rating and that each power supply is
connected to a separate power source.
Verify that the cable or cord connecting the power supply to the external power source is
securely in place and that there is no moisture accumulating near the router.
Verify that the cable or cord from the power source to the router is not damaged. If the
insulation is cracked or broken, replace the cable or cord immediately.
Verify that the power cables or cord do not touch or obstruct access to other router
components, and that they do not drape where people could trip on them.
Replace an AC Power Supply
An AC-powered router has two load-sharing, redundant AC power supplies. Each power
supply is hot-removable and hot-insertable, as described in “Field-Replaceable Units (FRUs)”
on page 4. When one power supply fails or is powered down, the other power supply
automatically assumes the entire electrical load for the router.
To replace an AC power supply, perform the following procedures:
Remove an AC Power Supply on page 137
Install an AC Power Supply on page 138
136
M40 Internet Router Hardware Guide
Replace an AC Power Supply
Remove an AC Power Supply
The AC power supplies are located at the bottom rear of the chassis (see Figure 2). Each AC
power supply weighs approximately 20 lb (9 kg).
Do not leave a power supply slot empty for more than a
short time while the router is operational. The power
supply must remain in the chassis for proper airflow.
To remove an AC power supply, follow this procedure (see Figure 53):
1.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on
the chassis.
2.
Press the power switch on the power supply faceplate to the OFF (O) position.
If you are not removing the power supply, but simply
powering it off, wait at least 60 seconds before turning it
back on. If you need to power it off again, wait for at least
60 seconds after powering it on.
3.
Unplug the power cord from the appliance inlet on the faceplate.
4.
Loosen the thumbscrew at each upper corner of the power supply faceplate, using a
Phillips screwdriver if necessary.
5.
Lift and hold up the safety interlock lever, which is directly below the appliance inlet.
6.
While holding the safety interlock lever up, turn the extractor/inserter counterclockwise
until the power supply disengages from the backplane.
7.
Grasp the handle on the power supply faceplate and pull firmly to slide the unit about
halfway out of the chassis.
8.
Place one hand under the power supply to support it, then slide it completely out of the
chassis.
Maintain and Replace the Power Supplies
137
Replace an A C Power Supply
Figure 53: Remove an AC Power Supply
Captive screw
Extractor/inserter
1018
Safety
interlock lever
Install an AC Power Supply
To install an AC power supply, follow this procedure:
138
1.
Verify that the switch on the power supply faceplate is in the OFF (O) position.
2.
Locate the power cord shipped with the router, which should be appropriate for your
geographical location (see “AC Power Cord Specifications” on page 45).
3.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on
the chassis.
4.
Grasp the handle on the power supply faceplate with one hand and place the other hand
under the unit to support it.
5.
With a finger of the hand that is grasping the handle, lift and hold up the safety interlock
lever, which is just below the appliance inlet.
6.
While holding the safety interlock lever up, slide the power supply into the chassis until
it contacts the backplane.
7.
Still holding the safety interlock lever up, turn the extractor/inserter clockwise until the
power supply engages with the connectors on the backplane.
8.
Push the safety interlock lever down.
9.
Using a Phillips screwdriver, tighten (but do not overtighten) the thumbscrew at each
upper corner of the power supply faceplate.
M40 Internet Router Hardware Guide
Replace an AC Power Supply
10. Insert the appliance coupler end of the power cord into the appliance inlet on the power
supply faceplate and insert the plug into an AC power source receptacle. Verify that the
power cord does not block access to router components or drape where people could
trip on it.
11. Press the power switch on the power supply to the ON ( | ) position. Verify that the green
LED labeled OK on the power supply faceplate eventually lights steadily.
After a power supply is turned on, it can take up to 60
seconds for status indicators—such as LEDs on the power
supply, show chassis commands, and messages on the
craft interface LCD—to indicate that the power supply is
functioning normally. Ignore error indicators that appear
during the first 60 seconds.
If the router is completely powered down when you power
on the power supply, the Routing Engine boots as the
power supply completes its startup sequence. If the
Routing Engine finishes booting and you need to power
down the router again, first issue the CLI
request system halt command. For complete instructions,
see “Disconnect AC Power from the Router” on page 140.
If after powering on the power supply you must power it
off, wait at least 60 seconds. After powering off a power
supply, wait 60 seconds before turning it back on.
Figure 54: Install an AC Power Supply
Captive
screw
Extractor/inserter
1035
Safety interlock lever
Maintain and Replace the Power Supplies
139
Disconnect and Connect A C Power
Disconnect and Connect AC Power
The power cord that plugs into the appliance inlet on the faceplate of each AC power supply
provides direct connection to the external power source. See the following sections:
Disconnect AC Power from the Router on page 140
Connect AC Power to the Router on page 140
Disconnect AC Power from the Router
To disconnect AC power from the router, follow this procedure:
1.
On the console or other management device connected to the Routing Engine, enter CLI
operational mode and issue the following command to shut down the router software.
For more information, see the JUNOS Internet Softw are Oper ational Mode Command
Reference: Pr otocols, Class of Service , Chassis, and Management .
user@host> request system halt
Wait to continue until a message appears on the console confirming that the operating
system has halted.
2.
Press the power switch on both power supply faceplates to the OFF (O) position.
3.
Unplug the power cord from both power supplies.
When both AC power supplies are installed in the chassis,
both power cords (one for each power supply) must be
unplugged to disconnect power completely.
Connect AC Power to the Router
140
1.
Verify that the power supplies are fully inserted in the chassis, that the thumbscrews and
extractor/inserters on their faceplates are tightened, and that the power switches on
both faceplates are in the OFF (0) position.
2.
For both power supplies, verify that the ends of the power cord are firmly plugged into
the appliance inlet on the power supply faceplate and the external power source
receptacle.
3.
Turn on the power to the management device that is connected to the Routing Engine
through the craft interface port labeled CONSOLE, AUXILIARY, or MANAGEMENT ETHERNET.
For more information on connecting management devices, see “Connect the Router to
Management and Alarm Devices” on page 119.
M40 Internet Router Hardware Guide
Replace a DC Power Supply
4.
Press the power switch on the faceplate of one power supply to the ON ( | ) position. The
green OK LED on the power supply faceplate blinks rapidly for a short time, then lights
steadily.
After a power supply is turned on, it can take up to 60
seconds for status indicators—such as LEDs on the power
supply, show chassis commands, and messages on the
craft interface LCD—to indicate that the power supply is
functioning normally. Ignore error indicators that appear
during the first 60 seconds.
The Routing Engine boots as the power supply completes
its startup sequence. If the Routing Engine finishes booting
and you need to power down the router again, first issue
the CLI request system halt command. For complete
instructions, see “Disconnect AC Power from the Router”
on page 140.
If after powering on the power supply you must power it
off, wait at least 60 seconds. After powering off a power
supply, wait 60 seconds before turning it back on.
5.
Press the second power switch to the ON ( | ) position and observe the LEDs on the
second power supply faceplate. They should light as described in Step 4.
If the LEDs are not lit in the appropriate pattern after 60 seconds, repeat the power
supply installation procedures described in “Install an AC Power Supply” on page 138,
and the previous steps in this procedure.
6.
On the management device, monitor the startup process to verify that the system has
booted properly.
Replace a DC Power Supply
A DC-powered router has two load-sharing, redundant DC power supplies. Each power
supply is hot-removable and hot-insertable, as described in “Field-Replaceable Units (FRUs)”
on page 4. When one power supply fails or is powered down, the other power supply
automatically assumes the entire electrical load for the router.
To replace a DC power supply, perform the following procedures:
Remove a DC Power Supply on page 142
Install a DC Power Supply on page 144
Maintain and Replace the Power Supplies
141
Replace a DC P ower Supply
Remove a DC Power Supply
The DC power supplies are located at the bottom rear of the chassis (see Figure 2). Each DC
power supply weighs approximately 20 lb (9 kg).
Do not leave a power supply slot empty for more than a
short time while the router is operational. The power
supply must remain in the chassis for proper airflow.
To remove a DC power supply, follow this procedure:
1.
Turn off the power flowing from the DC power source to the power supply. Ensure that
the voltage across the leads of the DC power cables that you are disconnecting is 0 V
and that there is no chance that the cable leads might become active during removal.
2.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on
the chassis.
3.
Flip the power switch on the power supply faceplate to the OFF (O) position. See
Figure 55
If you are not removing the power supply, but simply
powering it off, wait at least 60 seconds before turning it
back on. If you need to power it off again, wait for at least
60 seconds after powering it on.
Figure 55: Flip the Power Switch on a DC Power Supply to the OFF Position
Power switch
142
M40 Internet Router Hardware Guide
1128
.
Replace a DC Power Supply
4.
Using a Phillips screwdriver, loosen the screws securing the protective shield over the
power terminal studs and remove the shield. See Figure 56.
Figure 56: Remove the Protective Shield from the Terminal Studs
.
Protective
shield
1130
Washer
5.
Using a 7/16-in. nut driver or wrench, loosen the nuts that secure the power cable lugs to
the terminal studs. Remove the nuts, washers, and lug from each set of terminal studs.
See Figure 57.
Do not substitute a metric nut driver or wrench. A tool that
does not fit the nuts exactly can damage them. If a 7/16-in.
tool is not available, use pliers or an adjustable wrench.
6.
Using a 7/16-in. nut driver or wrench, loosen the nuts that secure the grounding cable
lug to the grounding studs. Remove the nuts, washers, and lug from the grounding studs.
Figure 57: Remove Cables from a DC Power Supply
.
Locking
washers
Cable lug
Terminal studs
Input
Return
1131
Nuts
Grounding studs
7.
Loosen the thumbscrew at each upper corner of the power supply faceplate, using a
Phillips screwdriver if necessary.
8.
Lift and hold up the safety interlock lever, which is just below the power switch.
Maintain and Replace the Power Supplies
143
Replace a DC P ower Supply
9.
While holding the safety interlock lever up, turn the extractor/inserter counterclockwise
until the power supply disengages from the backplane. See Figure 58.
10. Grasp the handle on the power supply faceplate and pull firmly to slide the unit about
halfway out of the chassis.
11. Place one hand under the power supply to support it, then slide it completely out of the
chassis.
1129
Figure 58: Remove a DC Power Supply
Install a DC Power Supply
To install a DC power supply, follow this procedure:
144
1.
Verify that the power from the DC power source is shut off. Ensure that the voltage
across the leads of the DC power cables that you are connecting is 0 V and that there is
no chance that the cable leads might become active during connection.
2.
Verify that the power switch on the power supply faceplate is in the OFF (O) position.
3.
Attach an ESD strap to your bare wrist and connect the strap to one of the ESD points on
the chassis.
4.
Grasp the handle on the power supply faceplate with one hand and place the other hand
under the unit to support it.
5.
With a finger of the hand that is grasping the handle, lift and hold up the safety interlock
lever, which is just below the power switch.
6.
While holding the safety interlock lever up, slide the power supply into the chassis until
it contacts the backplane.
7.
Still holding the safety interlock lever up, turn the extractor/inserter clockwise until the
power supply engages with the connectors on the backplane. See Figure 59.
8.
Push the safety interlock lever down.
M40 Internet Router Hardware Guide
Replace a DC Power Supply
9.
Using a Phillips screwdriver, tighten (but do not overtighten) the thumbscrew at each
upper corner of the power supply faceplate.
1132
Figure 59: Install a DC Power Supply
10. Slide the grounding cable lug onto the grounding studs at the lower right corner of the
power supply faceplate. Secure the lug, first with locking washers, then with nuts. Using
a 7/16-in. nut driver or wrench, tighten the nuts.
Do not substitute a metric nut driver or wrench. A tool that
does not fit the nuts exactly can damage them. If a 7/16-in.
tool is not available, use pliers or an adjustable wrench.
11. If the protective shield is installed over the power supply terminals, use a Phillips
screwdriver to loosen and remove the screws that secure the shield to the power supply
(see Figure 60).
Figure 60: Remove the Protective Shield from the Terminal Studs
.
Protective
shield
1130
Washer
Maintain and Replace the Power Supplies
145
Replace a DC P ower Supply
12. Slide the power cable lugs onto the terminal studs on the power supply faceplate (see
Figure 61):
Connect the positive (+) source cable lug to the return terminal, which is labeled
RTN.
Connect the negative (–) source cable lug to the input terminal, which is labeled
–48V.
Run the power cables to the left on the left power supply, and to the right on the right
power supply. This arrangement enables you to replace a power supply without having
to detach the cables from the other power supply.
There is no standard color coding for DC power cables. The
color coding used by the external DC power source at your
site determines the color coding for the leads on the power
cables that attach to the circuit breaker box. You must
ensure that the connections at the circuit breaker box
maintain the proper polarity. The power source DC cables
might be labeled (+) and (–) to indicate their polarity.
Figure 61: Attach Cables to a DC Power Supply
.
Locking
washers
Cable lug
Terminal studs
Input
Return
1131
Nuts
Grounding studs
13. Secure the cable lug to the terminal studs, first with locking washers, then nuts. Using a
7/16-in. nut driver or wrench, tighten the nuts.
Do not substitute a metric nut driver or wrench. A tool that
does not fit the nuts exactly can damage them. If a 7/16-in.
tool is not available, use pliers or an adjustable wrench.
14. Verify that the power cabling from the source DC breaker to the power supply is correct.
146
M40 Internet Router Hardware Guide
Disconnect and Connect DC Power
15. Reinstall the protective shield covering the terminal studs.
16. Press the power switch on the power supply to the ON ( | ) position. Verify that the green
LED labeled OK on the power supply faceplate eventually lights steadily.
After a power supply is turned on, it can take up to 60
seconds for status indicators—such as LEDs on the power
supply, show chassis commands, and messages on the
craft interface LCD—to indicate that the power supply is
functioning normally. Ignore error indicators that appear
during the first 60 seconds.
If the router is completely powered down when you power
on the power supply, the Routing Engine boots as the
power supply completes its startup sequence. If the
Routing Engine finishes booting and you need to power
down the router again, first issue the CLI
request system halt command. For complete instructions,
see “Disconnect DC Power from the Router” on page 147.
If after powering on the power supply you must power it
off, wait at least 60 seconds. After powering off a power
supply, wait 60 seconds before turning it back on.
Disconnect and Connect DC Power
On a DC-powered router, the power cables from the external DC power sources connect to
terminal studs on each power supply. To disconnect or connect power to the router, perform
the following procedures:
Disconnect DC Power from the Router on page 147
Connect DC Power to the Router on page 149
Disconnect DC Power from the Router
To disconnect DC power from the router, follow this procedure:
1.
On the console or other management device connected to the Routing Engine, enter CLI
operational mode and issue the following command to shut down the router software.
For more information, see the JUNOS Internet Softw are Oper ational Mode Command
Reference: Pr otocols, Class of Service , Chassis, and Management .
user@host> request system halt
Wait to continue until a message appears on the console confirming that the operating
system has halted.
2.
Turn off the power flowing from each DC power source to a power supply. Ensure that
the voltage across the leads of the DC power cables is 0 V and that there is no chance
that they might become active during removal.
Maintain and Replace the Power Supplies
147
Disconnect and Connect DC P ower
3.
Flip the power switch on both power supplies to the OFF (O) position. See Figure 62.
Figure 62: Flip the Power Switch on a DC Power Supply to the OFF Position
.
1128
Power switch
4.
Using a Phillips screwdriver, loosen and remove the screws securing the protective shield
over the terminal studs on one power supply. Remove the shield.
5.
Using a 7/16-in. nut driver or wrench, loosen the nuts securing the cable lugs to the
terminal studs on the power supply, then remove the nut and washer from each
terminal stud (see Figure 63).
Do not substitute a metric nut driver or wrench. A tool that
does not fit the nuts exactly can damage them. If a 7/16-in.
tool is not available, use pliers or an adjustable wrench.
6.
Remove the cable lugs from the terminal studs.
Figure 63: Remove Cables from a DC Power Supply
.
Locking
washers
Cable lug
Terminal studs
Input
Return
1131
Nuts
Grounding studs
7.
148
M40 Internet Router Hardware Guide
If you are decommissioning the router, loosen and remove the nuts and washers that
secure the grounding lug to the power supply and remove the grounding lug.
Disconnect and Connect DC Power
8.
If not immediately attaching replacement cables, replace the protective shield over the
terminal studs and tighten the screws that secure it to the box.
9.
Verify that the removed cables are not touching or blocking access to any router
components.
10. Repeats Steps 4 through 9 for the other power supply.
Connect DC Power to the Router
Connect DC power to the router by attaching power cables from external DC power sources
to the terminal studs on the power supplies. Power and grounding cables are not supplied
with the router. For information about the required cable type, see “DC Power and Grounding
Cable Specifications” on page 46.
The router must be connected to two separate external DC
power sources, one for each set of terminal studs on the
circuit breaker box.
There is no standard color coding for DC power cables. The
color coding used by the external DC power source at your
site determines the color coding for the leads on the power
cables that attach to the circuit breaker box. You must
ensure that the connections at the circuit breaker box
maintain the proper polarity. The power source DC cables
might be labeled (+) and (–) to indicate their polarity.
To connect DC power to the router, follow this procedure:
1.
Ensure that the voltage across the leads of the DC power source cables that you are
connecting is 0 V and that there is no chance that the cable leads might become active
during installation.
2.
Verify that the power supplies are fully inserted in the chassis, that the thumbscrews and
extractor/inserters on their faceplates are tightened, and that the power switches on
both faceplates are in the OFF (0) position. See Figure 64.
3.
Attach the grounding cable to a proper earth ground, if it is not already.
4.
Slide the grounding cable lug onto the grounding studs at the lower right corner of the
power supply faceplate. Secure the lug, first with locking washers, then with nuts. Using
a 7/16-in. nut driver or wrench, tighten the nuts.
Do not substitute a metric nut driver or wrench. A tool that
does not fit the nuts exactly can damage them. If a 7/16-in.
tool is not available, use pliers or an adjustable wrench.
Maintain and Replace the Power Supplies
149
Disconnect and Connect DC P ower
Figure 64: Power Switch on a DC Power Supply in the OFF Position
.
5.
1128a
Power switch
If the protective shield is installed over the power supply terminals, use a Phillips
screwdriver to loosen and remove the screws that secure the shield to the power supply
(see Figure 65).
Figure 65: Remove the Protective Shield from the Terminal Studs
.
Protective
shield
1130
Washer
6.
Slide the power cable lugs onto the terminal studs on the power supply faceplate (see
Figure 66):
Connect the positive (+) source cable lug to the return terminal, which is labeled
RTN.
Connect the negative (–) source cable lug to the input terminal, which is labeled
–48V.
Run the power cables to the left on the left power supply, and to the right on the right
power supply. This arrangement enables you to replace a power supply without having
to detach the cables from the other power supply.
There is no standard color coding for DC power cables. The
color coding used by the external DC power source at your
site determines the color coding for the leads on the power
cables that attach to the circuit breaker box. You must
ensure that the connections at the circuit breaker box
maintain the proper polarity. The power source DC cables
might be labeled (+) and (–) to indicate their polarity.
150
M40 Internet Router Hardware Guide
Disconnect and Connect DC Power
Figure 66: Attach Cables to a DC Power Supply
.
Locking
washers
Cable lug
Terminal studs
Input
Return
1131
Nuts
Grounding studs
7.
Secure the cable lugs to the terminal studs, first with locking washers, then nuts.
8.
Verify that the DC power source wiring from the source DC breaker to the power supply
is correct.
9.
Reinstall the protective shield covering the terminal studs.
10. Repeat Steps 4 through 9 for the other power supply.
11. Turn on the power to the management device that is connected to the Routing Engine
through the craft interface port labeled CONSOLE, AUXILIARY, or MANAGEMENT ETHERNET.
For more information on connecting management devices, see “Connect the Router to
Management and Alarm Devices” on page 119.
12. Press the power switch on the power supply to the ON ( | ) position. Verify that the green
LED labeled OK on the power supply faceplate eventually lights steadily.
After a power supply is turned on, it can take up to 60
seconds for status indicators—such as LEDs on the power
supply, show chassis commands, and messages on the
craft interface LCD—to indicate that the power supply is
functioning normally. Ignore error indicators that appear
during the first 60 seconds.
The Routing Engine boots as the power supply completes
its startup sequence. If the Routing Engine finishes booting
and you need to power down the router again, first issue
the CLI request system halt command. For complete
instructions, see “Disconnect DC Power from the Router”
on page 147.
If after powering on the power supply you must power it
off, wait at least 60 seconds. After powering off a power
supply, wait 60 seconds before turning it back on.
Maintain and Replace the Power Supplies
151
Disconnect and Connect DC P ower
13. Press the power switch on other power supply to the ON ( | ) position and confirm that
the OK LED lights as described in Step 4. If the LED is not lit after 60 seconds, repeat the
power supply installation procedures described in “Install a DC Power Supply” on
page 144 and the previous steps in this procedure.
14. On the management device, monitor the startup process to verify that the system has
booted properly.
152
M40 Internet Router Hardware Guide
Download