Operation Manual

advertisement
Part No. Z1-005-300, IB023371
Nov 2011
Instruction manual
AC Multi Outlet Cable OT02-KPM
This AC multi outlet cable is connected to the KPM series for use. It enables you to measure the EUT just by
connecting the EUT to the outlet. This makes it easy to wire the measurement circuit.
Before using this outlet cable, thoroughly read the user's manual of the KPM series.
Packing list
When you receive the product, check that all accessories are
included and that the accessories have not been damaged
during transportation. If any of the accessories are damaged or
missing, contact your Kikusui agent or distributor.
Item
Quantity
AC multi outlet cable
1
Instruction manual (this manual)
1
China RoHS sheet
1
Names, functions and dimensions
Multi outlet
40
Wire with crimping terminal
(red and white)
7.5
7.5
235
250
Approx. 1200
SENSING switch
Select the measurement
circuit.
90
OUTPUT switch
You can use this to turn
the multi outlet output
on and off.
Wire with a safety terminal
adapter (red and black)
Hole for fixing
the cable in place
4-φ5
9.5
59
9.5
AC inlet
A OUTPUT 250V 15A
OUTPUT
ON/OFF
WARNING㆙࿌
B
AC INPUT
250V 15A
OT02-KPM
࣭TO AVOID AN ELECTRIC SHOCK,THE MAINS SUPPLY CORD
PROTECTIVE GROUNDING CONDUCTOR MUST BE CONNECTED
TO AN ELECTRICAL GROUND.
࣭THIS OUTLET STRIP MUST BE CONNECTED
TO AN AC POWER SUPPLY’S OUTPUT.
࣭ឤ㟁஦ᨾ㜵Ṇࡢࡓࡵࠊ㟁※ࢥ࣮ࢻࡢGND⥺ࢆ
NB00591-1
ࠉ☜ᐇ࡟᥋ᆅࡋ࡚ࡈ౑⏝ࡃࡔࡉ࠸ࠋ
࣭஺ὶ㟁※⿦⨨ࡢฟຊ࡟᥋⥆ࡋ࡚౑⏝ࡋ࡚ࡃࡔࡉ࠸ࠋ
KIKUSUI ELECTRONICS CORP. MADE IN JAPAN
G N L
OUTPUT
ON/OFF
A
OUTPUT
VOLTAGE
U(RED)
+ (BLACK)
-
B
A
OUTPUT
SENSING KPM
A
AC INPUT
L
N
G
SENSING
CURRENT
I (RED)
+
- (WHITE)
B
AC INPUT
B
This indicates how the measurement circuit switches
according to the position of the SENSING switch.
Magnet
Unit: mm
Connection
The illustration below shows how to connect the cable to the
KPM1000. For information on the connection terminals of other
KPM series units, see the appropriate user's manual.
WARNING Risk of electric shock.
• Before you connect the cable to a KPM
series, turn off the AC power supply that
you are using.
• Use a three-core power cord, and be sure
to ground it.
A power cord for connecting to the AC power supply is not
included. Obtain a power cord that has a plug that is the correct
shape and that supports the appropriate rated voltage and
rated current.
Voltage input terminals
terminal
KPM1000
Connection example, KPM1000
U terminal
Current input terminals
terminal
I terminal
Be sure to attach
the terminal cover.
Wire with crimping terminal (red)
Be sure to connect this to the
output of the AC power supply.
Do not connect this directly to the
outlet of a commercial AC line.
Wire with crimping terminal (white)
A
PUT
OUT
V 15A
UT 250
TP
A OU
OT 0
UT
OUTPFF
ON/O
B
UT
AC INP
V 15A
250
PM
2 -K
D
COR TED
PLY
SUP CONNEC
MAINS T BE
CK,THETOR MUS
IC SHO DUC
CTR ING CON
ELE
TED
91-1
ID AN GROUND UND.
NEC
AVO
CON .
NB005
࣭TO ECTIVE ICAL GRO T BE
PUT
MUS
PROT ELECTRSTRIP PLY’S OUT ⥺ࢆ
AN
GND
TO OUTLET ER SUPࢥ࣮ࢻࡢ
ࠋ
IS
JAPAN
ࡉ࠸
࣭TH AN AC POWࡵࠊ㟁※ࡉ࠸ࠋ
E IN
ࡃࡔ
ࡋ࡚
ࡢࡓ
MAD
ࡃࡔ
౑⏝
TO ஦ᨾ㜵Ṇ
P.
౑⏝
ࡋ࡚
࡚ࡈ
COR
᥋⥆
࣭ឤ㟁࡟᥋ᆅࡋ
ຊ࡟
ONICS
ࡢฟ
CTR
ࠉ☜ᐇ㟁※⿦⨨
ELE
࣭஺ὶ KIKUSUI
NING
WAR
㆙࿌
T
L
G N
OUTPU
A
T
OUTPUF
ON/OF
UT
AC INP
L
N
G
B
KPM
SING
SEN
GE
VOLTA )
U(RED K)
AC
+
- (BL
ENT
CURR D)
I (RE
)
ITE
+
- (WH
ING
SENS
UT
AC INP
B
Use a power cord that meets the rated voltage and rated current
of the EUT that you will connect to the multi outlet.
Wire with a safety terminal
adapter (red)
Wire with a safety terminal
adapter (black)
Measurement circuit selection (SENSING switch selection)
Depending on the measured current or measured voltage, the
power meter's measured results may be affected by input
impedance. To minimize the power loss, use the SENSING
switch to select the appropriate measurement circuit.
The power loss that occurs during power measurement varies
depending on the model. For details, see the user's manual for
the appropriate KPM series.
±
I
• To measure a large current, select
measurement circuit A.
• To measure minute power, such as standby
power, select measurement circuit B.
r
r
AC power
supply
L
U
Load
L
AC power
supply
L
U
I
±
Load
L
R
R
N
N
N
±
Equivalent circuit of the power meter when
measurement circuit A is selected
N
±
r: Ammeter input impedance
R: Voltmeter input impedance
Equivalent circuit of the power meter when
measurement circuit B is selected
Connections to the multi outlet
The plugs that can be connected to the multi outlet are shown
in the following table.
WARNING Risk of electric shock. Do not use voltage or
current exceeding the rated value (250 V and
15 A) of multi outlet.
Connectable plugs and their ratings (excerpt from the
WCF5901 catalog by Panasonic Electric Works, Ltd.)
Country/Region
Standard
Japan
United States
Canada
JIS
UL
CSA
Plug type
Plug ratings
2-pin
15 A, 125 V
SEV
Italy
CEI
Plug type
Europe
Plug ratings
2-pin
2.5 A, 250 V
2-pin
10/16 A*1, 250V
2-pin with ground
CEE
DIN
10/16 A*1, 250 V, and
earth on the side
2-pin with ground
2-pin
7.5 A, 250 V
AS
Switzerland
Standard
2-pin with ground
15 A, 125 V
2-pin
10 A, 250 V
Australia
Country/Region
2-pin with ground
10 A, 250 V
10/16 A*1, 250 V, and
earth on both sides
2-pin
5 A, 250 V
2-pin with ground
15 A, 250 V
2-pin with ground
5 A, 250 V
2-pin
10 A, 250 V
2-pin with ground
10 A, 250 V
2-pin with ground
10 A, 250 V
United Kingdom
BS
2-pin with ground
15 A, 250 V
2-pin with ground
13 A, 250 V
*1. The rated current of the multi outlet is 15 A. It cannot be used
when exceeding the rated current.
Specifications
Specification
Item
Specification
Maximum operating voltage
250 Vac
Withstand voltage
Maximum operating current
15 Aac
Between the AC input and the
chassis: 1500 Vac for 1 minute
Insulation resistance
Between the AC input and the
chassis at 500 Vdc: 100 MΩ or higher
Item
Environmental conditions
Installation location
Indoors, Overvoltage category I
Altitude 2000 m or less
Operating temperature
and humidity ranges
0 °C to +40 °C, 20 %rh to 80 %rh
(no condensation)
Storage temperature
and humidity ranges
-20 °C to +70 °C, 90 %rh or less
(no condensation)
Earth continuity
0.1 Ω or less at 25 Aac
Cable Length
Approx. 1.2 m
Input terminal (inlet)
IEC 60320 C14 (UL)
Applicable socket IEC 60320 C13,
C15
Weight
Approx. 1.0 kg
KIKUSUI ELECTRONICS CORP.
1-1-3, Higashiyamata, Tsuzuki-ku, Yokohama, 224-0023, Japan
TEL : +81-45-593-7570 Fax : +81-45-593-7571
Website
http://www.kikusui.co.jp/en