© 2014 OSRAM Low Voltage SSP-LNV 45372 SSM-LNV 45373 SCP-0450 45363 SCP-1500 45364 SCM-0500 45365 SCM-1000 45366 SCM-2000 45367 SWM-1200 45369 SWP-WV00 45368 SWP-HBAY 45371 SWP-LRNG 45370 Specifications subject to change without notice. Line Voltage LMS087R1 3-14 ENCELIUM® Occupancy Sensor Application Guide OSRAM is a registered trademark of OSRAM GmbH. ENCELIUM and Polaris 3D are registered trademarks. www.osram-americas.com Phone1-800-LIGHTBULB Danvers, MA 01923 USA Wall Switch Mounting Technology Coverage (Sq. Ft.) Multi-Technology 2100 2400 1500 360° 500 Voltage 360° 120-277Vac* 24Vdc 20 25 35 800/2700 C Conference Room C Copy Room B 30 Low Profile B C B B B A A 25 A File Room 8' - 10' Wide View High Bay Long Range B C A A A B A A A A B A A A B A A A B www.osram-americas.com/ENCELIUM B C A A A A A A B Loading Dock A Office Open B 10' - 40' Multi-Use C Hallway Office Small 26° 15 A A Day Care Center B 7.3° Ceiling / Wall Sensors Cubicle Office Executive 100x33 0°C to 40°C / 0 to 95% Non-Condensing, Indoor Use Only Cafeteria Computer Room 55x7 N/A Wall Switch Sensors C 2500 110° 30s-30m with 6s Test Mode Single Pole, No Neutral Required Classroom 1200 Manual or Self-Adjusting, Self-Calibrating 0°C to 40°C / 20% to 90% Non-Condensing, Indoor Use Only Applications 2000 30s-30m 800/2700 Feature Passive Infrared 8' - 10' N/A Consumption (mA) 1000 180° Self-Adjusting Time Delay Environmental Operating Temperature/Humidity 450 Multi-Technology 4' Manual Wall, Corner or Ceiling Passive Infrared 32°-180° Mounting Height (Ft.) Wattage/VA Ceiling Passive Infrared Pattern Adjustment Ceiling / Wall Sensors Americas Headquarters Wall Switch Sensors 100 Endicott Street Specifications B A A A A A A A A B A A A A Open Area B A A B A A A A A A A Restroom Non-Partitioned B B Restroom Partitioned C B Storage Room A B Vending Room C A A B B B B A B A A B Office With Cubicles Parking Garage B C A A A A A A A A B B B Warehouse Aisles Warehouse Open C Work Space General B A A A Rating Key: A = Best sensor for application, B = Good sensor for application, C = Acceptable sensor for application NOTE: Power Packs and Power Base Adaptor available. ENCELIUM Occupancy Sensors, Power Base Adaptors and Power Packs are covered by the ENCELIUM Energy Management System Limited warranty. This guide is designed to assist you in the specification and application of ENCELIUM Occupancy Sensors. The Application Guide recommendations are based on typical room usage specifications, always take into consideration room size, shape and unique usage circumstances. To learn more about ENCELIUM Sensors or for further assistance in selecting the correct occupancy sensors for your applications, call 1-800-LIGHTBULB or visit www.osram-americas.com/ENCELIUM. C Occupancy Sensor Application Guide ENCELIUM® Occupancy Sensors Wall-Switch Sensors Item Number Ordering Description Wall-Switch PIR Occupancy Sensor (no neutral) 45372 SSP-LNV Wall-Switch Multi-Technology Occupancy Sensor (no neutral) 45373 Description SSM-LNV Low-Voltage Sensors Wall Mount Rating Coverage Description Item Number Ordering Description Operating Frequency Coverage Incandescent: 800W @ 120V; Fluorescent:1200VA @ 120V, 2700VA @ 277V. 50/60Hz; Motor: 1/4 HP @ 120V 180°, 2100SF PIR Wide-View Wall Mount Occupancy Sensor 45368 SWP-WV00 — 110°, 2500SF Incandescent/Tungsten: 800W @ 120V; Fluorescent: 1200VA @ 120V, 2700VA @ 277V. 50/60Hz; Motor: 1/4 HP @ 120V 180°, 2400SF Multi-Technology Wall Mount Occupancy Sensor 45369 SWM-1200 32kHz 110°, 1200SF PIR Long-Range Wall Mount Occupancy Sensor 45370 SWP-LRNG — 100 ft., 33 ft. wide @ 100 ft. high PIR High-Bay Wall Mount Occupancy Sensor 45371 SWP-HBAY — 55 ft., 7 ft. wide @ 30 ft. high Control Input Power Supply Output 20A fluorescent/incandescent @ 120V, 20A fluor. @ 277V; 1HP @ 120V, 2HP @ 240V 5mA, 24Vdc 150mA, 24Vdc 15A fluorescent @ 347V; 1HP @ 120V, 2HP @ 240V; HVAC: 0.5A @ 120Vac, 1A @ 30Vdc 5mA, 24Vdc 120mA, 24Vdc Description Item Number Ordering Description Power Input Relay Rating Power Pack 45374 PPK-020 120-277Vac, 50/60Hz Power Pack with HVAC relay 45375 PPK-347 347Vac, 60Hz Agency Listings & Code Compliance: UL/cUL Listed, FCC Certified, and meets ASHRAE Standard 90.1 requirements. Agency Listings & Code Compliance: cUL/US Certified, meets ASHRAE Standard 90.1 requirements and CEC Title 24 requirements. Adjustable swivel neck rotates 80° vertically and 60° horizontally to allow wall or ceiling mount installation. Agency Listings & Code Compliance: ETL/cETL Listed, CSA (SSM Model) UL Listed/CSA Certified (SSP Model), CEC Title 24 Compliant, FCC Compliant. Wallplates sold separately. All models are 120-277V. Power Packs Power Pack Capacity Formula ENCELIUM power packs can be used to provide power to one or more occupancy sensors. Since current consumption of occupancy sensors may vary, the best way to ensure you order the correct number of power packs and add-a-relays is by using this formula: # of Sensor Model As X Sensor A current consumption rating SWM-1200 SWM-1200 SSM-LNV SSP-LNV Field-of-View Field-of-View Low-Voltage Sensors PPK-020 / PPK-347 + # of Sensor Model Bs X Sensor B current consumption rating ≤ Power Supply Output Item Number 45368, 45370, 45371 45363, 45364 45365, 45369 45366 45367 Current Ordering Description Consumption SWP-WV00, SWP-LRNG, SWP-HBAY 15mA SCP-0450, SCP-1500 20mA SCM-0500, SWM-1200 25mA SCM-1000 35mA SCM-2000 30mA Ceiling Mount Description Item Number Ordering Description Operating Frequency Coverage PIR Ceiling Mount Occupancy Sensor 45363 45364 SCP-0450 SCP-1500 — — 360°, 450SF 360°, 1500SF Multi-Technology Ceiling Mount Occupancy Sensor 45365 45366 45367 SCM-0500 SCM-1000 SCM-2000 40kHz 40kHz 32kHz 180°, 500SF 360°, 1000SF 360°, 2000SF SWP-LNRG Agency Listings & Code Compliance: cUL/US Certified, meets ASHRAE Standard 90.1 and CEC Title 24 requirements. Power Base Adaptor SWP-WV00 SWP-HBAY SWP-LRNG SCP-0450 Description SCP-1500 SWP-HBAY SWP-WV00 Converts any ENCELIUM low-voltage ceiling or wall mount occupancy sensor to a self-contained line voltage unit Item Number Ordering Description 45376 PBA-015 Power Input/Output Rating Power Input: 120-277Vac, 50/60Hz Control Output: 24Vdc, 40mA 15A Agency Listings & Code Compliance: cUL/US Certified. SCP-0450/1500 ENCELIUM EMS Application For Greater Savings Combine with the ENCELIUM Energy Management System to gain considerable energy savings in addition to occupancy sensing: SCM-0500 —P olaris 3D® Software enables the addition of Daylight Harvesting, Time Scheduling, Task Tuning, Variable Load Shedding and Personal Control for significantly greater energy savings SCM-0500 PBA-015 (Occupancy sensor not included) — Software Remapping: any sensor to any zone — Software Adjustable: Extended time-out — Connects directly to ENCELIUM Sensor Interface Module SCM-1000 SCM-1000/2000 —B ACnet Interface (optional): Occupancy sensing for building automation, HVAC, security, traffic data, etc. SCM-2000 For more information on the ENCELIUM Energy Management System, refer to LMS075 – ENCELIUM Brochure. For more applications and wiring diagrams, visit www.osram-americas.com/ENCELIUM