DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML2 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML2 LED: 0-10V Dimming Driver Wiring (Dims down to 10%) DIML2 Dimmer Compatibility Chart Manufacturer 120V / 277V Crestron Crestron Crestron Crestron Crestron Leviton Lightolier (Philips) Lutron Product Part Number Dimmed Light Output Range iLux dimmer expansion module DIN Rail dimmer DIN Rail analog output module 8 Channel dimmer module 8 Channel dimmer module IllumaTech dimmer Vega Diva CLS-EXP-DIMFLV DIN-4DIMFLV4 DIN-A08 GLX-DIMFLV8 GLXP-DIMFLV8 IP710-DLX V2000FAMU DVTV-XX 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER FIXTURE DIMMER: 0-10V (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GND CLASS 2 CONTROL WIRES LINE RELAY (BY OTHERS) NEUTRAL DIMMER: 0-10V w/ POWER SWITCHING DIML2 0-10V DIMMING (NO RELAY) FIXTURE (BY OTHERS) LINE 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GROUND GND NEUTRAL USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-2 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML3 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML3 LED: Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / LED Dimming Driver Wiring (Dims down to 1%) 120V only. DIML3 Dimmer Compatibility Chart Manufacturer 120V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Product Part Number Dimmed Light Output Range Sensor+ Cabinet Unison DRd Cabinet Maestro Wireless® 600W dimmer Maestro Wireless® 1000W dimmer HomeWorks® QS adaptive dimmer HomeWorks® QS 600W dimmer HomeWorks® QS 1000 W dimmer Caseta Wireless® Pro 1000W dimmer Stanza® dimmer RadioRA® 2 adaptive dimmer RadioRA® 2 1000 W dimmer myRoom DIN power module HomeWorks® QS wallbox power module Homeworks® DIN power module HomeWorks® wallbox power module GRAFIK Eye® QS control unit GRAFIK Eye® 3000 control unit RPM-4U module RPM-4A module GP dimming panels Ariadni CL 250W dimmer Diva CL 250W dimmer Grafik T CL or RF CL dimmer Nova T CL 250W dimmer ELV10 ELV10 MRF2-6ND-120MRF2-10ND-120HQRD-6NAHQRD-6NDHQRD-10NDPD-10NXDSZ-6NDRRD-6NARRD-10NDMQSE-4A1-D HQRJ-WPM-6D-120LQSE-4A1-D HWI-WPM-6D-120 QSGR-, QSGRJGRX-3100-, GRX-3500HW-RPM-4U-120, LP-RPM-4U-120 HW-RPM-4A-120, LP-RPM-4A-120 Various AYCL-253PDVCL-253P-, DVSCCL-253PGT-250M-, GTJ-250MNTCL-250- 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100%-1% 100%-1% 100%-1% 100%-1% Qty Fixtures Per Dimmer* Fixture Wattage 39W and Less 40W - 80W 1 – 26 1 – 13 1 – 26 1 – 13 1–8 1–4 1 – 13 1–6 1–8 1–4 1–8 1–4 1 – 13 1–6 1 – 13 1–6 1–8 1–4 1–8 1–4 1–6 1–3 1–6 1–3 1 – 26 1 – 13 1–6 1–3 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1 – 26 1 – 13 1–8 1–4 1–8 1–4 1–8 1–4 1 – 10 1–5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML3 2 WIRE PHASE DIMMING FIXTURE DIMMER: 2 WIRE PHASE (BY OTHERS) LED LINE SWITCHED HOT NEUTRAL GROUND BLACK WHITE DRIVER V+ RED V- BLACK GREEN GND ONLY FOR SWITCHES WITH NEUTRAL NEUTRAL USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-3 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML4 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%) DIML4 3-Wire Dimmer Compatibility Chart Manufacturer 120V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron 277V Only ETC ETC Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Lutron Product Part Number Dimmed Light Output Range Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Vareo Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10NTF-103PNF-10NF-103PVF-10SF-10P-, SF-103PDVF-103P-, DVSCF-103PAYF-103PVTF-6AMAF-6AM-, MSCF-6AMMRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-120, PHPM-3F-DV Various 100% - 1% 100% - 1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10-277NTF-103P-277NF-10-277NF-103P-277SF-12P-277-, SF-12P-277-3 DVF-103P-277-, DVSCF-103P-277AYF-103P-277VTF-6AMAF-6AM-277-, MSCF-6AM-277MRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-DV Various 100% - 1% 100% - 1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–53 1–26 1–53 1–26 1–41 1 – 20 1–20 1 – 10 1–41 1 – 20 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–20 1 – 10 1–15 1–7 1–15 1–7 1–15 1–7 1–15 1–7 1–15 1–7 1–41 1 – 20 1–41 1 – 20 40W and Less 41W - 80W 1–53 1–26 1–53 1–26 1–44 1 – 22 1–33 1 – 16 1–44 1 – 22 1–33 1 – 16 1–33 1 – 16 1–33 1 – 16 1–44 1 – 22 1–33 1 – 16 1–20 1 – 10 1–33 1 – 16 1–33 1 – 16 1–33 1 – 16 1–88 1 – 44 1–88 1 – 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML4 Continued ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%) DIML4 3 WIRE PHASE DIMMING FIXTURE DIMMER: 3 WIRE PHASE (BY OTHERS) CAP UNUSED ECOSYS WIRES DIMMED HOT SWITCHED HOT NEUTRAL LINE LED PURPLE GRAY PURPLE ORANGE BLACK WHITE GREEN GROUND DRIVER V+ RED V- BLACK GND NEUTRAL DIML4 LED: Lutron Hi-Lume A-Series LED Driver with EcoSystem Control / LED Dimming Driver Wiring (Dims down to 1%) Manufacturer 120V / 277V Lutron Lutron Lutron Lutron DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range Product PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DV-B QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–32 1 – 16 1–64 1 – 32 1–64 1 – 32 1–64 1 – 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 FIXTURE E1 WALL CONTROL (BY OTHERS) LINE NEUTRAL CAP UN-USED ORANGE WIRE PURPLE GRAY PURPLE ORANGE BLACK WHITE GREEN LED DRIVER V+ RED V- BLACK GND USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML4E and DIML4H ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML4E LED: Lutron 5 Series EcoSystem LED Driver / LED Dimming Driver Wiring (Dims down to 5%) Manufacturer 120V / 277V Lutron Lutron Lutron Lutron DIML4E EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range Product PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DV-B QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%–5% 100%–5% 100%–5% 100%–5% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–32 1 – 16 1–64 1 – 32 1–64 1 – 32 1–64 1 – 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4H LED: Lutron H Series EcoSystem LED Driver with Fade to Black (dims down to 1%) Manufacturer 120V / 277V Lutron Lutron Lutron Lutron DIML4E EcoSystem Dimmer Compatibility Chart Dimmed Light Part Number Output Range Product PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DV-B QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%–1% 100%–1% 100%–1% 100%–1% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 1–32 1 – 16 1–64 1 – 32 1–64 1 – 32 1–64 1 – 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4E and DIML 4H EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 FIXTURE E1 WALL CONTROL (BY OTHERS) LINE NEUTRAL CAP UN-USED ORANGE WIRE PURPLE GRAY PURPLE ORANGE BLACK WHITE GREEN LED DRIVER V+ RED V- BLACK GND USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-4EH Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML9 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML9 LED: TRIAC Forward Phase Dimming Driver Wiring (Dims down to 15%) 120V Only DIML9 2 WIRE PHASE DIMMING FIXTURE DIMMER: 2 WIRE PHASE (BY OTHERS) LED LINE SWITCHED HOT NEUTRAL GROUND BLACK WHITE DRIVER V+ RED V- BLACK GREEN GND ONLY FOR SWITCHES WITH NEUTRAL NEUTRAL USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-9 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML10 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML10 LED: ELV Reverse Phase Dimming Driver Wiring (Dims down to 15%) 120V Only DIML10 2 WIRE PHASE DIMMING FIXTURE DIMMER: 2 WIRE PHASE (BY OTHERS) LED LINE SWITCHED HOT NEUTRAL GROUND BLACK WHITE DRIVER V+ RED V- BLACK GREEN GND ONLY FOR SWITCHES WITH NEUTRAL NEUTRAL USAI Lighting ® www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 T 845–565–8500 F 845–561–1130 © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-10 Revised 02/15/2016 DIMMING DRIVER COMPATIBILITY SELECTION GUIDE DIML15 ® USAI Lighting DIMMING DRIVER WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS 1. Keep these instructions in a safe place for future reference. 2. Only qualified electricians in accordance to local codes should install these fixtures. 3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing. 4. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 5. Cap any wires not used separately (not together). DIML15 LED: 0-10V, 347V Dimming Driver Wiring (Dims down to 1%) 347V Only DIML15 Dimmer Compatibility Chart Manufacturer 347 Acuity Douglas Lighting Hubbell Leviton Leviton Lutron Lutron Product Dimmed Light Output Range Synergy ISD-BC WPN-5721, WPN-5822 Light Hawk2 LHD-IRS3-N347-xx Illumatech IP710-DLZ with 347V relay Centura Fluorescent Control System Nova NFTV-* dimmer plus 347V relay Diva DVTV-* dimmer plus 347V relay 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% 100% - 1% Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML15 0-10V DIMMING W/RELAY TO SWITCH POWER FIXTURE DIMMER: 0-10V (BY OTHERS) 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE LED DRIVER V+ RED V- BLACK NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GREEN GND CLASS 2 CONTROL WIRES LINE RELAY (BY OTHERS) NEUTRAL DIML2 0-10V DIMMING (NO RELAY) FIXTURE DIMMER: 0-10V w/ POWER SWITCHING (BY OTHERS) LINE 0-10V (-) GRAY 0-10V (+) PURPLE SWITCHED HOT BLACK NEUTRAL WHITE USAI Lighting NEUTRAL DRIVER RED V- BLACK GREEN GROUND ® LED V+ www.usailighting.com info@usailighting.com 1126 River Road New Windsor, NY 12553 GND T 845–565–8500 F 845–561–1130 NOTE: Quickship fixtures are shipped prewired for 0-10V dimming controls. If switched, nondimming operation is desired, cap off purple and gray wires separately at installation. Do NOT cap purple and gray wires together. © 2016. USAI, LLC. All rights reserved. All designs protected by copyright. I2-264-15 Revised 02/15/2016