RX16FT-IS Flush Mount Lift Rack SPECIFICATIONS Site Specifications Substructure Requirements Refer to 6367-T for full details Power Requirements 208-230 VAC, single phase power, 26 Amp Air Supply Requirements 90-150 PSI (6.2-10.3 bar) Jacks require 125 PSI (8.6 bar) for full capacity Minimum Concrete Spec. 3 in. (76 mm) thick, 3000 PSI (20,700kPA) rating Maximum Floor Slope 2 in. (51 mm) over 126 in. (3200 mm) Product Specifications Max. Vehicle Weight 16,000 lbs. (7257 kg) Max. Wheelbase RX16FT-IS Shown General Service 187 in. (4750 mm) Two-Wheel Alignment 182 in. (4623 mm) Four-Wheel Alignment 158 in. (4013 mm) Alignment Height All lock positions Min. Four-Wheel Alignment 88 in. (2235 mm) Lifting Speed 1 speed 60 seconds Lowering Speed 2 speed, 25 seconds MODEL FEATURES / DIMENSIONS FT-IS Features Dimension 9000-lb Swing Air Jacks (2) 92.5 in. Outside Width (W1) Two-Speed Lowering 2350 mm 40 in. Inside Width (W2) 1016 mm 231.375 in. Length (L) 5877 mm 26 in. Runway Width (R) 660 mm Raised Height (H1) 1829 mm 72 in. 14.75 to 15.25 in. Depth (H2) W2 375 to 387 mm R H1 H2 W1 L Continued on Page 2 For lift rack information visit: www.hunter.com/lift-racks For general inquiries visit: www.hunter.com or call 800-448-6848 For local contact visit: www.hunter.com/contact-hunter Form 6492-T, 06-15 Supersedes Form 6492-T, 08-13a Copyright © 2015, Hunter Engineering Company RX16FT-IS Flush Mount Lift Rack SPECIFICATIONS (Refer to 6367-T for substructure construction requirements) ! 96 1/2" (2451 mm) WARNING STAY BEHIND YELLOW LINE WHEN THE LIFT MOVES. HAWKEYE SERIES SENSORS AND PRONTO SYSTEMS HAVE SPACE REQUIREMENTS IN FRONT OF LIFT THAT MUST BE MET, REFER TO APPROPRIATE SITE REQUIREMENTS. OPTIONAL 1 1/2 IN. DIA. CONDUIT FOR COMMUNICATION CABLE TO ALIGNMENT CONSOLE 128-978-2 DECAL 128-978-2 (4 places on edging and 2 places on lift) ! WARNING OPT. FRONT STEP (12" (305 mm) MAX. DEPTH) 34 3/4" (883 mm) 64" (1626 mm) 41 3/8" (1051 mm) EXTENDER PLATES 51-2464-1-PPP AND RAMPS 147-141-1-PPP FILLER PLATE 51-2308-1 (4 places) (placed over 14" X 5" cutout) 14" (356 mm) PIT DEPTH OF 14 3/4" to 15 1/4" (375 mm to 387 mm) REQUIRED AT FRONT END OF PIT OPTIONAL CONSOLE LOCATION 5" (127 mm) SLOPE PIT FLOOR TOWARD DRAIN (1/2 ) ANGLE AROUND PIT PERIMETER: - not around 14" X 5" cutouts - painted safety yellow - not supplied by Hunter G N I N R AW ! G N I N R AW ! 141 3/4" (3600 mm) APPROX. 2" (51 mm) TYPICAL 45 6" MIN. RADIUS DRAIN LOCATED IN CENTER OF PIT CONDUIT EXIT FLUSH WITH PIT FLOOR ROUTE 4" MIN DIAMETER CONDUIT OR EQUIVALENT CLOSED CHANNEL FROM PIT FLOOR TO BASE OF CONSOLE 14" X 5" CUTOUT (4 places) 231 3/8" (5877 mm) 14" (356 mm) ENTIRE PIT (BOTTOM AND WALLS) MUST BE HARD TROWEL FINISH 5" (127 mm) CONSOLE CONDUIT DETAIL 22" (559 mm) VEHICLE APPROACH 16" (406 mm) RAMPS 147-141-1-PPP 33 3/4 (857 mm) OPTIONAL REAR STEP (6" (152 mm) MAX. HT.) G N I N R AW 32" (813 mm) BAY DOOR ** 15" TO 41" (381 TO 1041 mm) ! ** SITES WITH D.R.W. TRUCK TRAFFIC SHOULD USE 20" MIN. CONSOLE TO PIT DISTANCE. 6" MIN.* (152 mm) BAY DOOR * LONGER VEHICLES WILL NEED TO BE SERVICED WITH BAY DOOR OPEN. TO ACCOMMODATE MOST VEHICLES, INCREASE SPACE BEHIND PIT TO 39" (991 mm) OR GREATER. *Non-standard positioning of control console is limited to a maximum space between console and rack of 6 feet (1829 mm) at the approach ramp end and 17 feet (5182 mm) at the turnplate end. Additional threshold and perhaps hydraulic hoses will be required (refer to Installation Instruction for details).. All dimensions shown are for finished pit. Accomodate tile thickness as needed. Form 6492-T, 06-15 Supersedes Form 6492-T, 08-13a Copyright © 2015, Hunter Engineering Company