TL410-IND INDUCTION GARAGE LIGHTER Model Number: Accessories: Job:Type: Approvals: DESCRIPTION TRACE*LITE’s second generation TL410-IND series induction garage lighter is specifically designed for the unique thermal management required by induction lamps and generators. The induction lamp and lens assembly is sealed and gasketed while the enclosure for the generator is thermally isolated from the lamp assembly to ensure that the generator can operate at the coolest temperature possible. SPECIFICATIONS Construction: The TL410-IND is constructed of durable, corrosion resistant, die-cast aluminum featuring two integral assemblies designed to thermally isolate the two components that generate heat. The induction lamp and prismatic polycarbonate lens assembly is IP65 rated dust-tight and protected against low pressure jets of water from all directions, while the generator enclosure is IP53 rated to provide protection from dust and spraying water to allow for proper ventilation. The lamp/lens assembly is thermally isolated from the generator enclosure allowing for maximum heat dissipation allowing the end-user to benefit from the full 100,00hr+ lifetime performance potential of the induction system. Optics: The prismatic polycarbonate lens on the TL410-IND provides ideal diffusion and distribution of light with excellent efficiency. The polycarbonate lens also provides a superior level of protection for the induction lamp itself. The optic assembly is dust-tight to minimize the ingress of dirt that causes lumen depreciation. Electrical: The TL410-IND utilizes an electronic generator that produces a high frequency current that is controlled by an integrated circuit (IC) chip allowing for a power factor up to 96% with a THD of >10%. The TL410-IND has a standard input of 120~277VAC 50/60Hz that generates a very low 250KHz operating frequency and meets FCC and CE certification for EMC electromagnetic compatibility. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE Lamps: The TRACE*LITE TL410-IND series is available with a choice of 6 wattages starting from a 40W induction lamp that can replace a 70W traditional HID lamp, up to a 150W induction lamp that replaces a 250W traditional HID lamp (see table on page 2 for complete lamp performances). The induction lamps used in the TL410-IND provide a CRI of >80 and maintain nearly 70% of the lamp’s initial lumen output after 100,000 hours of operation. Standard CCT is 5000K, consult factory for availability of other color temperatures. Installation: TRACE*LITE’s TL410-IND is ideal for mounting to any vertical surface in either a surface mount configuration over a standard J-box or can be suspended using a pendant mount. The TL410-IND is designed for easy installation by a single person which can translate to substantial labor savings. Swivel mounting brackets for either round or square J-boxes are also available. Dimming (Option: DIMST & DIM010V): The TL410-IND series from TRACE*LITE is available with two different dimming options. The “DIMST” provides a step dimming option for fixed outputs of 0%/50%/100% and is ideal for simple dimming applications using motion control sensors, photoelectric switches or time clock controls. The “DIM010V” option is for applications requiring a fixture compatible with 0-10V dimming control systems and includes a generator that has 0-10V control leads. The dimming options available allow the TL410-IND to qualify for many energy rebate programs across the country that help offset initial systems costs. 10800269 06/13 Warranty: Any housing component that fails due to manufacturer’s defect is guaranteed for two years from time of shipment. Induction lamps and generators are not manufactured by TRACE*LITE and will be warranted by the manufacturer for a period of five years. TRACE*LITE will act as an agent for these suppliers and assist in any way possible. Warranty does not apply to damages caused by improper installation, abuse, fire, or acts of God. Fixture Performance Lamp Wattage Ballast Type Max Watts Amps @ 120V Amps @277V 40 >44W 0.37 0.16 2800 70W 60 >66W 0.55 0.24 4600 100W >88W 0.73 0.32 80 Electronic Up to 96% Min. Temp -40°C (-40°F) Max Temp 40°C (104°F) Initial Lumens CCT Rated Lamp Life CRI 6400 5000K >80 (Ra) Replaces HID 150W >110W 0.92 0.40 120 >132W 1.10 0.48 9600 200W 150 >165W 1.38 0.60 12000 250W Sample Photometrics 8000 100,000 Hour 175W Dimensions TL410-IND-120 Mounted at 10’ 11.82” (300mm) 50’ 40’ .1fc 30’ .5fc 1fc 3fc 5fc 3/4” SCREW HOLE 20’ Ø15” (381mm) 10’ 0.17” (4.3mm) 100 Power Factor 0 Ø2 Ø3 .36” (60 . Ø 54” mm 4. 69 (90m ) ”( m) 11 9. 2m m ) Approximate Weight: 15 lbs 10’ 20’ 30’ 40’ 0 10’ 20’ 30’ 40’ 50’ 50’ Ordering Information Example: TL410-IND-80-U-DMST Series Lamp Lamp Wattage Input Voltage TL410 IND = Induction 40 = 40 Watts U = Universal 120 ~ 277VAC Options (Factory Installed) SZXXX1 = Single Line Side Fuse (Specify 120 or 277VAC) 60 = 60 Watts DMST2 = Step Dimming (0% / 50% / 100%) 80 = 80 Watts DM010V2 = 0 - 10V Dimming 100 = 100 Watts 10YW = 10 Year Warranty 120 = 120 Watts 150 = 150 Watts Notes PC1 = 120VAC Photocontrol 1 Specify 120 or 277VAC 2 Dimming 3 Order Accessories3 (Field Installed) capable, control provided by others as separate line item PC2 = 277VAC Photocontrol SWPR = Swivel Pendant Mount (Round) SWPS = Swivel Pendant Mount (Square) 1911 W. Parkside Lane • Phoenix, AZ 85027 (800) 533-3948 • Fax: (623) 580-8948 www.barronltg.com