EPC14-1, EPC14-2 1' × 4' High Efficiency, e•poc® Full Distribution Luminaire / 1 or 2-Lamp T5, T8 PROJECT INFORMATION Project Name Type Catalog No. Date CONSTRUCTION FEATURES • Attractive fluorescent architectural recessed luminaire • T8 or T5 Fluorescent • Full distribution provides controlled high angle light for visual comfort • Advanced optical design produces high efficiencies • Exclusive T8 EnergyMax® tuned 1.04 ballast factor ballast • Step dimming options for both T5 and T8 expand energy saving and control opportunities • Low W/ft2 ratio meets the most restrictive lighting power density codes • Unique frameless optial system allows easy access to lamps and electrical from below the ceiling • Lens styles provide aesthetic alternatives • Low profile recessed housing fits tight plenum spaces • Damp location standard • Recessed, surface or cable mount ORDERING INFORMATION EPC 14 – MODEL NO. OF LAMPS EPC e∙poc® Full Distribution Luminaire 1 One 2 Two (T5 only) Luminaire housing, end caps and reflectors are die-formed code-gauge steel. Frameless optical system hinges from either side for easy access to lamps and electrical components. Mechanical light trap prevents light leaks. Latches are spring loaded. FINISH All visible parts are custom formulated soft, non-glare high-reflectance white powder coat finish, painted after fabrication. SHIELDING Lenses are high transmission extruded acrylic. INSTALLATION An access plate is furnished with each recessed fixture for fast wiring connections without the necessity to open the fixture or wireway. BALLASTS Energy efficient, thermally protected, auto-resetting HPF ballast, sound rated A. CEE NEMA Premium compliant. – CEILING TYPE – SHIELDING DL Delta Profile AIR FUNCTION Blank Static SH Shield Profile SIZE LAMP TYPE BALLAST 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28, or 25 Watt 54 4', T5HO: 54 or 51 Watt E Electronic T8, 0.88 Ballast Factor, Instant Start ESD Electronic T8, 0.88 Ballast Factor, Step Dimming, Programmed Start ED Electronic T8, T5, T5HO Dimming, Programmed Start4 ELW Electronic T8, 0.77 Ballast Factor, Low Wattage, Instant Start EHL Electronic T8, 1.18 Ballast Factor, High Wattage, Instant Start E104 Electronic T8, 1.04 Ballast Factor, Instant Start (N/A 1-Lamp) ESD104 Electronic T8, 1.04 Ballast Factor, Step Dimming, Programmed Start3 EP Electronic T5, T5HO, 1.0 Ballast Factor or T8, 0.88 Ballast Factor, Programmed Start EP104 Electronic T8, 1.04 Ballast Factor Programmed Start EP95 Electronic T5, 0.95 Ballast Factor , Programmed Start (N/A T5HO, 1-Lamp) ESD95 Electronic T5, 0.95 Ballast Factor, Step Dimming, Programmed Start (N/A T5HO, 1-Lamp) EP115 Electronic T5, 1.15 Ballast Factor, Programmed Start (N/A T5HO, 1-Lamp) ESD115 Electronic T5, 1.15 Ballast Factor, Step Dimming, Programmed Start (N/A T5HO, 1-Lamp) ESD80 Electronic T5HO, 0.80 Ballast Factor, Step Dimming, Programmed Start (2-Lamp 54W only) Damp Label - standard 1 For drywall order Flange Kit accessories separately. 2 Order hanger accessories separately. 3 Not compatible with T8 25, 28, or 30 watt energy saving lamps. 4 Where available. 5 Not recommended for use with step or full dimming. 6 Not available with "A" air function. 7 Not available with Surface Mount ceiling types. 8 In-Fixture Module Antenna adds 2" to overall fixture height at power feed location. Protected by US Patents D593,246; D617,487; 7,901,105. Protected by Canada Patent 129,763. Additional Canada Patent Pending. Specifications subject to change without notice. CEILING COMPATIBILITY Designed for recessed installation in standard inverted tee grid ceilings (G), recessed installation in hard ceilings (G with FK accessory), surface mount at ceiling plane (SM) or cable mount suspension below ceiling plane (CM). For compatibility with specific ceilings contact your Hubbell Lighting representative. CERTIFICATION All luminaires are built to UL 1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Recessed models without emergency options are IC labeled. Emergency-equipped fixtures labeled UL 924. UL Sanitation Approved. – 14 1' × 4' FK14 1' × 4' Flange Kit, Single Mounting (for rows add FKCR) FKCR Flange Kit Row Adaptor CM 48Y1SC3F-KIT 48" Cable Mount Kit for 1' wide Cable Mount fixtures, 3 Wire EMERGENCY Field installation of battery packs requires use of remote test switch. Factory installed battery packs optional; includes installed test switch. EXAMPLE EPC14-132G-DL-EU-FO735 G Grid1 SM Surface Mount CM Cable Mount2 ACCESSORIES (ORDER SEPARATELY) ELECTRICAL Standard class “P”, thermally protected, auto-resetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CECcompliant ballast disconnect is standard. – VOLTAGE U 120V-277V 347 347V2 LAMPS F830 30K 78+CRI T8 Lamps Installed F835 35K 78+CRI T8 Lamps Installed F841 41K 78+CRI T8 Lamps Installed FO830 30K 82CRI T8 Lamps Installed FO835 35K 82CRI T8 Lamps Installed FO841 41K 82CRI T8 Lamps Installed FO28830 30K 82CRI 28W T8 Lamps Installed5 FO28835 35K 82CRI 28W T8 Lamps Installed5 FO28841 41K 82CRI 28W T8 Lamps Installed5 FOH830 30K High Lumen T8 Lamps Installed FOH835 35K High Lumen T8 Lamps Installed FOH841 41K High Lumen T8 Lamps Installed F5830 30K 85CRI T5 or T5HO Lamps Installed F5835 35K 85CRI T5 or T5HO Lamps Installed F5841 41K 85CRI T5 or T5HO Lamps Installed F5H830 30K High Lumen T5 Lamps Installed F5H835 35K High Lumen T5 Lamps Installed F5H841 41K High Lumen T5 Lamps Installed Page 1/2 Rev. 03/08/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com – OPTIONS C388 C488 C588 EL EL5 G1 G2 G3 GLR GMF NYC NYCU CP 3-Wire Flex 4-Wire Flex 5-Wire Flex T8 Emergency Battery Pack, 350-450 Lumens6 T5 or T5HO Emergency Battery Pack, 390-700 Lumens6 Single Gasket (door to housing) Double Gasketing (G1 and lens to door) Triple Gasketing (G2 and housing to ceiling) Fast Blow Fuse Slow Blow Fuse NYC Compliant NYC Compliant, Union Label Chicago Plenum RECESSED ARCHITECTURAL / EPC14-1, EPC14-2 EPC14-1, EPC14-2 1' × 4' High Efficiency, e•poc® Full Distribution Luminaire / 1 or 2-Lamp T5, T8 PHOTOMETRIC DATA 26 Recessed 0º = 90 90º = 90 Length: 3.83 Width: 0.85 Height: 0.00 Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet EPC14-128G e•poc™ Troffer Recessed 1-Lamp with Opal Delta Lens B228PUNV-C 1.00 F28T5 2600 34 Recessed 0º = 90 90º = 90 2271 2264 2253 2240 2227 2196 2156 2097 1991 1827 1580 1214 2271 2275 2266 2258 2248 2231 2215 2191 2165 2210 2018 1555 2271 2291 2296 2301 2310 2323 2414 2441 2330 2121 1790 1138 2271 2291 2322 2352 2402 2519 2500 2386 2194 1942 1561 835 2271 2298 2335 2371 2464 2531 2473 2339 2127 1852 1447 759 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 19.7 32.6 59.7 77.8 77.8 25.3 41.9 76.7 100.0 100.0 AVG. LUMINANCE (Candela/Sq. M.) 2222 2218 2210 2198 2186 2156 2116 2058 1953 1789 1523 1176 2222 2226 2219 2212 2202 2185 2162 2144 2117 2172 2018 1555 2222 2237 2240 2244 2258 2271 2361 2402 2320 2121 1790 1100 2222 2241 2270 2296 2346 2461 2460 2371 2204 1929 1542 797 2222 2241 2283 2315 2412 2479 2434 2324 2127 1840 1447 759 ZONAL LUMEN SUMMARY Zone 0-30 0-40 0-60 0-90 0-180 Lumens % Lamp % Fixt. 530 877 1607 2098 2098 20.4 33.7 61.8 80.7 80.7 70 84 76 69 63 58 54 50 46 43 40 80 50 30 80 77 70 64 61 54 54 47 48 41 43 36 39 32 35 29 32 26 30 24 10 74 60 49 41 35 31 27 24 21 19 70 82 74 67 61 56 52 48 45 42 39 70 50 30 79 76 68 63 60 54 53 46 47 40 42 35 38 32 35 28 32 26 29 23 10 73 59 49 41 35 30 27 24 21 19 50 75 65 57 51 45 41 37 34 31 29 50 30 73 61 52 45 39 35 31 28 25 23 10 70 57 48 40 35 30 27 24 21 19 INDOOR CANDELA PLOT 0 0 65 53 44 38 32 28 25 22 20 18 90 75 350 60 700 0 15 30 45 Horiz 0-180 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 45.0 0.0 Total Luminaire Efficiency 77.8% Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 74 Noncompliant $3.24 based on 3000 hrs. and $0.08 per KWH 90.0 25.3 41.8 76.6 100.0 100.0 Test 15281 Test Date 12/16/08 COEFFICIENTS OF UTILIZATION (%) 0.0 22.5 45.0 67.5 90.0 0 30 40 45 50 55 60 65 70 75 80 85 RC RW 1 2 3 4 5 6 7 8 9 10 ENERGY DATA Lumens % Lamp % Fixt. 542 897 1642 2140 2140 RCR 0 30 40 45 50 55 60 65 70 75 80 85 0º = 1.28 90º = 1.30 Length: 3.83 Width: 0.85 Height: 0.00 COEFFICIENTS OF UTILIZATION (%) 0.0 22.5 45.0 67.5 90.0 0º = 1.28 90º = 1.30 LUMINAIRE DATA Luminaire AVG. LUMINANCE (Candela/Sq. M.) RCR Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet EPC14-132G-DL e•poc™ Troffer Recessed 1-Lamp with Opal Delta Lens ICN-1P32-SC 0.90 F28T8 2750 Average Luminance Angle Luminaire Average Luminance Angle LUMINAIRE DATA Test 15282 Test Date 12/17/08 RC RW 1 2 3 4 5 6 7 8 9 10 70 87 79 72 66 60 55 51 48 45 42 80 50 30 83 80 72 67 63 56 56 48 50 42 44 37 40 33 37 30 34 27 31 24 10 77 62 51 43 37 32 28 25 22 20 70 85 77 70 64 58 54 50 46 43 41 70 50 30 82 78 71 65 62 55 55 48 49 42 44 37 40 33 36 29 33 27 30 24 10 75 61 50 42 36 32 28 25 22 20 50 78 68 59 52 47 42 38 35 32 30 50 30 75 63 54 47 41 36 32 29 26 24 10 73 60 49 42 36 31 28 24 22 20 0 0 67 55 46 39 33 29 25 23 20 18 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance ENERGY DATA Total Luminaire Efficiency 80.7% Luminaire Efficacy Rating (LER) IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 0 Noncompliant $3.87 based on 3000 hrs. and $0.08 per KWH Page 2/2 Rev. 03/08/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com INDOOR CANDELA PLOT 90 75 350 60 700 0 15 30 45 Horiz 0-180 0.0 45.0 90.0 RECESSED ARCHITECTURAL / EPC14-1, EPC14-2 EPC14-1, EPC14-2 1' × 4' High Efficiency, e•poc® Full Distribution Luminaire / 1 or 2-Lamp T5, T8 DIMENSIONAL DATA CEILING COMPATIBILITY Type G FKCR 37/8" Side 12" End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. Delta profile shown; others available. For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK14 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK14 & (1) FKCR) FK14 Flange Kit 117/8" 48" 31/2" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Side End For hard ceiling applications, order FK14 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. Row cut out dimensions using FK14s & FKCR adapters: Width 123/8", Length [48" × (# in row)] + 3/8". Example: (48" × 2) + 3/8" = 963/8" Flange kit cut out dimension for single unit only: 123/8" × 483/8" DIMENSIONAL DATA - SURFACE AND CABLE MOUNT 0 1⁄4" – 0 1⁄2" KO (4) PLCS 431⁄2" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. 25⁄8" 9" 0 11⁄2" 51⁄8" 49" SURFACE MOUNT Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock-outs, 1⁄4" to 1⁄2" provided as shown, marked "A". 13" 41⁄4" CABLE MOUNT Order CM ceiling type. Access plate supplied for cable mounting or suspension. Use CM48Y2C3F-KIT 48" cable mount kit. Includes 3 wire feed cord. For other wiring needs, contact Hubbell representative. Mounting knock-outs, 1⁄4" to 1⁄2", provided as shown, marked "A" Mounting Collar Text 4 1⁄2" x 5" Mounting Collar (SM only).For Cable Mount (CM) a 2" x 3" access plate with (2) 7⁄8" K.O.s provided in place of Mounting Collar shown. Page 3/2 Rev. 03/08/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com RECESSED ARCHITECTURAL / EPC14-1, EPC14-2