SER14 1' × 4' High Efficiency, Serrano® Architectural Luminaire / T5, T5HO, T8 PROJECT INFORMATION FEATURES Project Name Type Catalog No. Date CONSTRUCTION Housing is constructed of heavy gauge steel, die formed for extra rigidity. Optical system hinges and latches from either side for easy access to electrical components. Mechanical light trap prevents light leaks. Latches are spring loaded. Optional integrated sensor(s) are placed within luminous opening and do not interfere with hinging and latching mechanisms. • FINISH • All visible parts are custom formulated soft, non-glare high • reflectance white powder coat finish, painted after fabrication. • SHIELDING Lenses are high transmission extruded acrylic with an interlocking • design for structural integrity and ease of maintenance. Optional • integrated sensors are placed in an architecturally styled lens opening at one or both ends of the luminaire. • INSTALLATION An access plate or mounting collar is furnished with luminaire for fast wiring connections without the necessity to open the fixture HUBBELL SUSTAINABLE DESIGN SOLUTION FEATURES* or wireway. • Made with 90% recycled steel BALLASTS • Made of 80% recyclable materials by weight Energy-efficient, thermally protected, automatic resetting, Class “P”, • Job pack available for minimizing amount of packaging material at job site high power factor, sound rated A, unless otherwise specified. For a • Individual cartons made of 100% recycled corrugated *Please go to specific vendor and/or ballast, specify as option. CEE NEMA Premium www.hubbell.com/recovery/hsi/hsi.htm for Hubbell Sustainable Design compliant. • • • • • Attractive recessed fluorescent with architecturally enhanced triple lens design T8 or T5 Fluorescent Full distribution provides controlled high angle light for visual comfort Advanced optical design produces high efficiencies Hinged optical system allows easy access to lamps and electrical from below the ceiling Lenses interlock for structural integrity Two optional lens aesthetics Exclusive optional T8 EnergyMax® tuned 1.04 ballast factor ballast Step and full dimming options for both T5 and T8 expand energy saving and control opportunities Recessed, surface or cable mount Most configurations produce low W/ft2 to meet the most restrictive lighting power density codes Optional architecturally styled integration of daylight, occupancy, or daylight and occupancy sensor(s) ELECTRICAL Standard class "P," thermally protected, auto-resetting HPF ballast, sound rated A. CEE NEMA Premium compliant. All ballast leads extend a minimum of 6" through access location. NEC/CEC compliant ballast disconnect is standard. EMERGENCY Field installation of battery packs requires use of remote test switch. CEILING COMPATIBILITY Designed for recessed installation in standard inverted tee grid ceilings (G), recessed installation in hard ceilings (G with FK accessory), Surface mount at ceiling plane (SM) or cable mount suspension below ceiling plane (CM). For compatibility with specific ceilings contact your Hubbell Lighting representative. CERTIFICATION All luminaires are built to UL1598 standards and bear appropriate UL and cUL or CSA labels. Damp location labeling is standard. Emergency equipped fixtures labeled UL924. Adheres to LM79, LM80 and TM21 standards. IC rating optional (see availability table). UL Sanitation Approved. Solutions Feature Criteria. ORDERING INFORMATION SER 14 – MODEL SER Serrano® Recessed Architectural Luminaire SIZE NO. OF LAMPS 1 One 2 Two 3 Three (N/A T5HO) 28 4', T5: 28 Watt 32 4', T8: 32, 30, 28, or 25 Watt 54 4', T5HO: 54 or 51 Watt ACCESSORIES (ORDER SEPARATELY) FK14 1' × 4' Flange Kit, Single Mounting (for rows add FKCR) FKCR Flange Kit Row Adaptor CM 48Y1SC3F 48" Cable Mount Kit for 1' wide Cable Mount fixtures, 3 Wire WSR WattStopper Sensor Commissioning Remote8 WSOR WattStopper Sensor Occupant Remote8 For drywall, order Flange Kit accessories separately. 2 Order hanger accessories separately. 3 Not compatible with T8 25, 28, or 30 watt energy savings lamps. 4 Where available. 5 Not recommended for use with step or full dimming. 6 Not available with surface mount. 7 In-Fixture Module Antenna adds 2" to overall fixture height at power feed location. 8 For details, see Sensors table on page 3. Page 1/3 Rev. 03/08/16 F – CEILING TYPE G Grid1 SM Surface Mount CM Cable Mount2 LAMP TYPE 14 1' × 4' EXAMPLE SER14-232G-RF-E104U-FO835 SHIELDING C Contour R Rail – – REFLECTOR VOLTAGE F Full U 120V-277V 347 347V4 BALLAST E ESD ED ELW EHL E104 ESD104 EP EP104 EP95 ESD95 EP115 1 ESD115 ESD80 Electronic T8, 0.88 Ballast Factor, Instant Start Electronic T8, 0.88 Ballast Factor, Step Dimming, Programmed Start3 Electronic T8, T5, T5HO Dimming, Programmed Start3,4 Electronic T8, 0.77 Ballast Factor, Low Wattage, Instant Start Electronic T8, 1.18 Ballast Factor, High Wattage, Instant Start Electronic T8, 1.04 Ballast Factor, Instant Start Electronic T8, 1.04 Ballast Factor, Step Dimming, Programmed Start3 Electronic T5, T5HO, 1.0 Ballast Factor or T8, 0.88 Ballast Factor, Programmed Start Electronic T8, 1.04 Ballast Factor, Programmed Start Electronic T5, 0.95 Ballast Factor , Programmed Start (N/A T5HO, 2-Lamp Only) Electronic T5, 0.95 Ballast Factor, Step Dimming, Programmed Start (N/A T5HO, 2-Lamp Only) Electronic T5, 1.15 Ballast Factor, Programmed Start (N/A T5HO, 2-Lamp Only) Electronic T5, 1.15 Ballast Factor, Step Dimming, Programmed Start (N/A T5HO, 1, 2-Lamp Only) Electronic T5HO, 0.80 Ballast Factor, Step Dimming, Programmed Start (2-Lamp 54W only) © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com – F830 F835 F841 FO830 FO835 FO841 F028830 F028835 F028841 FOH830 FOH835 FOH841 F5830 F5835 F5841 F5H830 F5H835 F5H841 OPTIONS C388 C488 C588 EL LAMPS EL5 30K 78+CRI T8 Lamps Installed 35K 78+CRI T8 Lamps Installed 41K 78+CRI T8 Lamps Installed GLR 30K 82CRI T8 Lamps Installed GMF 35K 82CRI T8 Lamps Installed NYC 41K 82CRI T8 Lamps Installed IC ODP 30K 82CRI 28W T8 Lamps Installed5 35K 82CRI 28W T8 Lamps Installed5 41K 82CRI 28W T8 Lamps Installed5 DP 30K High Lumen T8 Lamps Installed DPO 35K High Lumen T8 Lamps Installed 41K High Lumen T8 Lamps Installed 30K 85CRI T5 or T5HO Lamps Installed ODW 35K 85CRI T5 or T5HO Lamps Installed 41K 85CRI T5 or T5HO Lamps Installed DW 30K High Lumen T5 Lamps Installed 35K High Lumen T5 Lamps Installed OW 41K High Lumen T5 Lamps Installed CP 3-Wire Flex 4-Wire Flex 5-Wire Flex T8 Emergency Battery Pack, 350-450 Lumens T5 or T5HO Emergency Battery Pack, 390-700 Lumens Fast Blow Fuse Slow Blow Fuse NYC Compliant IC Rated Occupancy and Daylight Sensors, Philips8 Daylight Sensor, Philips8 Daylight Sensor with Dim-to-Off, Philips8 Occupancy and Daylight Sensors, WattStopper8 Daylight Sensor, WattStopper8 Occupancy Sensor, WattStopper8 Chicago Plenum RECESSED ARCHITECTURAL / SER14 SER14 1' × 4' High Efficiency, Serrano® Architectural Luminaire / T5, T5HO, T8 PHOTOMETRIC DATA Test 5287 Test Date 6/22/12 INDOOR CANDELA PLOT SER14-232G-RF-EU-FO28 SER Serrano, Recessed Architectural 1 x 4 2-lamp with Rail center lens, linear prismed side lenses, and full distribution reflector ICN-2P32-N 0.89 F28T8 2750 53 Recessed 0º = 90 90º = 90 0º = 1.24 90º = 1.29 Length: 3.79 Width: 0.83 Height: 0.00 Luminaire Ballast Ballast Factor Lamp Lumens per Lamp Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in Feet RCR COEFFICIENTS OF UTILIZATION (%) RC RW 1 2 3 4 5 6 7 8 9 10 70 89 81 74 68 63 58 54 50 47 44 80 50 30 86 82 75 70 66 60 59 52 53 45 47 40 43 36 39 32 36 30 33 27 10 79 65 55 46 40 35 31 28 25 23 70 87 79 72 66 61 57 53 49 46 43 70 50 30 84 81 73 69 65 59 58 51 52 45 47 40 42 36 39 32 36 29 33 27 10 78 64 54 46 40 35 31 28 25 23 50 80 71 62 56 50 45 41 38 35 32 50 30 78 66 57 50 44 39 35 32 29 26 AVG. LUMINANCE (Candela/Sq. M.) 90 0.0 22.5 45.0 67.5 90.0 75 850 60 1700 0 15 0.0 30 Horiz 0-180 45.0 10 76 63 53 45 39 35 31 28 25 23 Zone 1323 2152 3676 4487 4487 5666 5508 5293 5076 4770 4409 3976 3619 3192 2856 2483 2002 5666 5591 5266 5023 4722 4403 4079 3765 3442 3107 2818 1963 5666 5749 5378 5163 4919 4695 4448 4218 3942 3504 2641 1492 5666 5788 5445 5265 5078 4898 4695 4437 3942 3080 1931 1492 5666 5820 5481 5328 5137 4969 4749 4461 3882 2869 1852 1610 90.0 ENERGY DATA Lumens % Lamp % Fixt. 0-30 0-40 0-60 0-90 0-180 0 30 40 45 50 55 60 65 70 75 80 85 45 ZONAL LUMEN SUMMARY 0 0 69 58 50 43 37 32 29 26 23 21 Average Luminance Angle LUMINAIRE DATA 24.1 39.1 66.8 81.6 81.6 29.5 48.0 81.9 100.0 100.0 Total Luminaire Efficiency 81.6% Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 75 Noncompliant $3.20 based on 3000 hrs. and $0.08 per KWH RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance DIMENSIONAL DATA CEILING COMPATIBILITY Type G FKCR 53⁄8" 12" Side End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK14 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK14 & (1) FKCR) FK14 Flange Kit 12" 48" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Side End For hard ceiling applications, order FK14 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. Page 2/3 Rev. 03/08/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com Row cut out dimensions using FK14s & FKCR adapters: Width 123/8", Length [48" × (# in row)] + 3/8". Example: (48" × 2) + 3/8" = 963/8" Flange kit cut out dimension for single unit only: 123/8" × 483/8" RECESSED ARCHITECTURAL / SER14 SER14 1' × 4' High Efficiency, Serrano® Architectural Luminaire / T5, T5HO, T8 DIMENSIONAL DATA - SURFACE OR CABLE MOUNT (4) 1/4 - 1/2" K.O. Mounting Locations, "A" NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. 197/8" 3" 4 1⁄2" x 5" Mounting Collar (SM only). For Cable Mount (CM) a 2" x 3" access plate with (2) 7⁄8"K.O.s provided in place of Mounting Collar shown. 3" 63/8" 11/2" 49" 13" 6" SURFACE MOUNT Order SM ceiling type. Mounting collar required for surface mounting. (4) Mounting knock outs, ¼" to ½" provided as shown, marked "A". CAT # SUFFIX SENSOR MANUFACTURER ODP DP DPO ODW DW OW Philips Philips Philips WattStopper WattStopper WattStopper OPTIONAL INTEGRAL SENSORS DIM-TO-OFF POWERPACK INCLUDED SENSOR FUNCTION DAYLIGHTING IN LUMINAIRE HOUSING Occupancy and Daylight Sensors Daylight Sensor Daylight Sensor with Dim-to-Off Occupancy and Daylight Sensors Daylight Sensor Occupancy Sensor No No Yes No No No OPTIONAL SENSOR HANDHELD REMOTES SENSOR ACCESSORY MANUFACTURER FUNCTION OPTIONAL? WSR WSOR WattStopper WattStopper CABLE MOUNT Order CM ceiling type. Access plate supplied for cable mounting or suspension. Use CM48Y2C3F-KIT 48" cable mount kit. Includes 3 wire feed cord. For other wiring needs, contact Hubbell representative. Mounting knock-outs, 1⁄4" to 1⁄2", provided as shown, marked "A". Commissioning Dimming Remote Yes Yes Yes No Yes Yes Yes Yes # PER PROJECT 1 Determined by others. Note: WSR, if selected, requires a minimum of one per project. WSOR, if selected, allows individual control; therefore the quantity needed is determined by others. Page 3/3 Rev. 03/08/16 © 2016 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com RECESSED ARCHITECTURAL / SER14