lighting since 1895 Features and Options Recessed Open Appearance Lensed E-Lamp "Pulse Start" Downlight: 50 to 150 Watt Features Lamp • Designed for metal halide E-lamps. See chart below for standard and optional wattages. • See Option -43 and chart below for lower wattage or HPS availability. Socket • Vertical. Pulse rated. Glazed porcelain. • Nickel-plated brass screw shell. Silicone leads. Reflector • Self-flanged clear specular Alzak® aluminum. • Ten optional reflector finishes available. Lens • UV absorbing clear tempered glass mounted to reflector. Also see Options. Ballast Assembly: Specify Voltage • WhisperPackTM fully encapsulated 180oC rated HPF pulse start ballast. HRR-06025 6" 150W • 50-150 watt: Class H, high reactance for 120 volt and Options -65, -66; linear reactor for 277 volt. • Capacitor and ignitor supplied. • Dimming (-39) and electronic (-96) ballasts available. See Options. • Cool, quiet, long-life. Silicone leads. • Visible and easily serviced in all ceilings including dry wall. Fuse • Fused primary. Renewable. Not for 480 volt. Housing • Acrylic enameled aluminum. • Cool: Dissipates heat across entire surface area. Ventilated. • Rustproof: Exceeds 1000 hour ASTM 5% salt spray test. • Entire luminaire serviced from below through removable reflector and lens. • Built-in plaster frame. Outlet Box • Prewired 14 GA (NEC) galvanized steel, UL listed; with removable insulated cover. • 1/2" and 3/4" knockouts. Installation • 27" galvanized hanger bars supplied (2). • Fully adjustable universal mounting brackets supplied (2). • Recesses indoor or outdoor in covered locations. UL, C-UL (Canada) Listings • Wet, damp or dry locations, covered ceilings. • Through-branch circuit conductors (6 #12). Three Year Limited Warranty • Complete standard fixture, including ballast. Thermal Protection • Per current NEC. Wattage Availability and Cut-Out Dimensions Standard Wattage Catalog No. Lamp/Base HRR-06025 ED-17/Med Option -43: Lower Wattage Pulse MH -24 (HPS) Pulse MH -24 (HPS) 150 150 50-125 35-100 Max. Standby Ceiling Wattage Cut-Out (-49-65-66-LS) Diameter 100 6.5" Options -65 Sources and Ballasts -24 HPS ballast instead. See wattage chart above for available wattages. Specify voltage. -39 Electronic dimming ballast instead, for pulse start metal halide. Consult factory for wattage and voltage availability. Regulating electronic MH ballast instead. Consult factory for availability in 175W or above. -96 Lower wattage: See Option -43 chart above for available lower wattages. Specify voltage. -120 120 volt, 60 Hz. ballast. -277 277 volt, 60 Hz. ballast. -347 347 volt, 60 Hz. ballast. Consult factory for dimming or electronic. -97 Other voltage ballast instead. Consult factory. Relays, Standbys, Lamps PS MET HALIDE REV JULYSEPT 20022015 -49 -LP -LS Wattage and Voltage -43 -66 Reflectors and Trims -16 -31 -32 -45 (See Chart) Extra circuit DCB socket. Do not energize simultaneously with main source. Also see -LS. Electronic standby system and DCB socket. Following HID outage, provides immediate light until HID restrikes. Also see -66 and -LS. Electronic time delay standby system and DCB socket. Following outage, provides light until HID reaches 70% output. Also see Option -LS. With lamp. Specify source, wattage, color temperature, and clear or coated. (3700oK standard for metal halide) Consult factory for other color temperatures. With T-4 DCB tungsten halogen standby lamp. Use only with Options -49, -65 or -66. -63 -69 (Self-Flanged) Champagne Gold specular Alzak reflector. (CP x .93) White flange (only) on self-flanged reflector. Trim extender. Broadens trim flange O.D. by 1" to cover larger ceiling opening. Gasket above reflector flange. Stops dust streaks on ceiling. Dune specular Alzak reflector. (CP x .90) Wheat specular Alzak reflector. (CP x .88) -70 -71 -77 -90 -91 -93 -94 SofTex Clear softly etched reflector. (CP x .90) SofTex Dune softly etched reflector. (CP x .81) SofTex Pewter softly etched reflector. (CP x .78) SofTex Champagne Gold softly etched reflector. (CP x .84) SofTex Wheat softly etched reflector. (CP x .80) Pewter specular Alzak reflector. (CP x .85) Custom color reflector. Consult factory. Lenses -15 Prismatic flat C#73 glass instead. -ML UV absorbing tempered Microlux glass instead. Concentrates distribution. Mounting Options -79 -85 Extension collar for up to 2" thick ceilings. Ceiling Panel; with recessed fixture hole. Lays-in 2' x 2' grid. White. Other Options -99 Special modification. Consult factory. THE KIRLIN COMPANY 3401 EAST JEFFERSON AVENUE • DETROIT, MICHIGAN 48207-4232 (313) 259-6400 • Fax: (313) 259-9409 or (313) 259-3121 • www.kirlinlighting.com THE KIRLIN COMPANY RESERVES THE RIGHT TO CHANGE, WITHOUT NOTICE, DETAILS OR SPECIFICATIONS IN PRODUCT DESIGN. Alzak® is a registered trademark of ALCOA. lighting since 1895 Performance at a Glance Plan View * Dia. (in ft.) shown is where FC value is half the FC at nadir. C.U. (Coefficients of Utilization) Tables are available on request. Please contact your Kirlin representative. HRR-06025 150W HRR-06025 (Coated Lamp) HRR-06025-15 (Clear Lamp) 90˚ Cone of Light* 90˚ Ft. 6 8 10 12 14 16 60˚ 4400 45˚ 6600 0˚ 15˚ 30˚ FC 184.8 104.0 66.5 46.2 33.9 26.0 Dia. 5.0 6.6 8.3 9.9 11.6 13.2 2500 60˚ 5000 45˚ 7500 0˚ EFFIC: 51.6% S/MH 0.8 15˚ 22.5 45.0 67.5 90.0 6653 6384 5275 3832 2418 1613 86 25 13 0 0 6653 6384 5275 3832 2418 1613 86 25 13 0 0 6653 6384 5275 3832 2418 1613 86 25 13 0 0 6653 6384 5275 3832 2418 1613 86 25 13 0 0 6653 6384 5275 3832 2418 1613 86 25 13 0 0 * LER (Luminaire Efficacy Rating) = Luminaire Effic. x Total Lamp Lumens x Ballast Factor JOB NAME TYPE CATALOG NUMBER VOLTAGE FC 209.0 117.6 75.2 52.3 38.4 29.4 Dia. 4.3 5.7 7.2 8.6 10.1 11.5 4000 60˚ 8000 45˚ 12000 0˚ EFFIC: 45.0% 15˚ 30˚ S/MH 0.4 Ft. 6 8 10 12 14 16 FC 365.4 205.5 131.6 91.4 67.1 51.4 Dia. 2.5 3.4 4.2 5.1 5.9 6.8 EFFIC: 47.6% ITL TEST #51695 *LER = 34.2 •AEC = $7.01 CANDLEPOWER DISTRIBUTION 0.0 22.5 45.0 67.5 90.0 7524 6210 5027 3533 1909 914 446 257 73 0 0 7524 6210 5027 3533 1909 914 446 257 73 0 0 7524 6210 5027 3533 1909 914 446 257 73 0 0 7524 6210 5027 3533 1909 914 446 257 73 0 0 7524 6210 5027 3533 1909 914 446 257 73 0 0 45.0 67.5 90.0 13155 13155 13155 10735 10735 10735 5636 5636 5636 3106 3106 3106 2011 2011 2011 1069 1069 1069 385 385 385 148 148 148 45 45 45 0 0 0 0 0 0 13155 10735 5636 3106 2011 1069 385 148 45 0 0 13155 10735 5636 3106 2011 1069 385 148 45 0 0 0.0 0 5 15 25 35 45 55 65 75 85 90 22.5 • AEC = Annual Energy Cost per 1000 lumens (based on 3000 hours use @ $0.08 KWH). APPROVAL STAMP PS MET HALIDE JULY 2015 2002 REV SEPT WATTAGE 0 5 15 25 35 45 55 65 75 85 90 Cone of Light* 75˚ Ft. 6 8 10 12 14 16 CANDLEPOWER DISTRIBUTION 0.0 SUBMITTAL DATA 90˚ ITL TEST #51696 *LER = 32.4 •AEC = $7.42 CANDLEPOWER DISTRIBUTION Input Watts 30˚ S/MH 0.7 ITL TEST #51682 *LER = 35.2 •AEC = $6.81 0 5 15 25 35 45 55 65 75 85 90 Cone of Light* 75˚ 75˚ 2200 HRR-06025-ML (Clear Lamp) or repair such fixture or refund the purchase price on presentation of proof of purchase and defective fixture at the offices of manufacturer within three years of original shipment. Liability of manufacturer is limited to the foregoing, and manufacturer shall not be liable for any other damages, direct or indirect, sustained or suffered by purchaser or any person. This warranty is supplied to the buyer in place of all other warranties, expressed or implied. Seller does not warrant as to merchantability or fitness for a particular use, nor will any oral statement constitute a warranty or amend this specific warranty. Abnormal use, abuse of the fixture, improper installation, or repair, or modification of the fixture without prior written authorization from the manufacturer will render the warranty void. Ft. Distance from fixture FC Footcandles (average) Dia. Circle of light at 50% of FC LIMITED WARRANTY: CATALOGED KIRLIN FIXTURES ARE WARRANTIED FREE OF DEFECTS IN WORKMANSHIP OR MATERIAL FOR THREE YEARS FROM DATE OF PURCHASE, INSTALLED TO N.E.C., IN NORMAL USE. Manufacturer at his option will replace Cone of Light Key HRR-06025