Edge Evolution Outline - Pinnacle Architectural Lighting

advertisement
EDGE OUTLINE
E V O L U T I O N
LED Recessed Linear
Perimeter Slot System
Project Name
Date
Catalog Number
Type
CONSTRUCTION Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing. Extruded alumi-
num module with reflector and lens for perfect perimeter illumination.
ELECTRICAL Electronic, 120 to 277 volt input and 36V output. 0-10 volt dimming standard.
LED All luminaire configurations tested in accordance with IES LM-79. Diodes tested in accordance with IES LM-80.
R9≥20, 27K is CRI≥91, 30K, 35K, and 40K is CRI≥83. Minimum lifetime greater than 60,000 hours.
MOUNTING Edge Evolution is designed to install into acoustical grid and inaccessible ceilings. Specify GX, FL, SF, NF
for individual and continuous runs (runs designed to fall on-grid). Consult factory for detailed installation instructions.
FINISH Standard powder-coat textured white, metallic silver, textured black, graphite or bronze painted finish on
exposed trim. Driver cover to be painted standard white when custom color specified. Consult factory for custom
colors.
WARRANTY Edge Evolutuion LED offered with a 5-year limited warranty. Covers LED, driver and fixture.
LABELS IC Rated, UL and cUL Listed, approved for dry/damp location unless otherwise noted.
Standard (EVL)
YEAR LED
WARRANTY
LFL
4-1/2”
(114.3mm)
4-1/2”
(114.3mm)
LED
Convertible
Convertible
LED
YEAR LED
WARRANTY
LFL
LFL
LED
Convertible
LED
LFL
EVL
L U M I N A I R E S P E C I F I C AT I O N
EVL_-
____-
___’-
___-
HOUSING
COLOR/LUMENS
LENGTH
MOUNTING
___-
VOLTAGE
Convertible
120- 120 V LED
277- 277 V
347- 347 V
UNV- UNV
(120-277)
Sample
Catalog #: EVL-30-24’-FL-120-1C-W
EVLS
__-
YEAR LED
WARRANTY
1
LFL
27K Color Temperature Lumen Options
2727K, 164 lumens/ft (4.0 watts/ft)
27HO- 27K, 313 lumens/ft (6.0 watts/ft)
27VHO- 27K, 404 lumens/ft (8.0 watts/ft)
30K Color Temperature Lumen Options
YEAR LED
3030K, 200 lumens/ft (4.0 watts/ft)
WARRANTY
30HO- 30K, 381 lumens/ft (6.0 watts/ft)
30VHO- 30K, 492 lumens/ft (8.0 watts/ft)
35K Color Temperature Lumen
Options
LFL
3535K, 209 lumens/ft (4.0Convertible
watts/ft)
35HO- 35K, 398 lumens/ft (6.0 watts/ft)LED
35VHO- 35K, 514 lumens/ft (8.0 watts/ft)
40K Color Temperature Lumen Options
4040K, 214 lumens/ft (4.0 watts/ft)
40HO- 40K, 409 lumens/ft (6.0 watts/ft)
40VHO- 40K, 527 lumens/ft (8.0 watts/ft)
4-1/4”
(107.9mm)
5-1/4”
(133.4mm)
Convertible
EVL- Edge Evolution Outline
EVLS- Edge
Evolution Outline Shallow
Shallow (EVLS)
CIRCUITING
__-
____
FINISH
OPTIONS
LED
Convertible
Circuit
1C- Single LFL
1D- Single Circuit Dimming5
1B- Single Circuit with
Battery Pack5, 6,11
1E- Single Circuit with
Emergency Circuit11
Acoustical Grid Ceiling
G1- 1” (25.4mm) Ceiling Grid
G9- 9/16” (14.3mm) Ceiling Grid
Convertible
GS-LFL Screw Slot Ceiling Grid
GB- 9/16” (14.3mm) Ceiling Grid with Bevel Trim
Inaccessible Ceiling
FL- Standard 1/2” (12.7mm Flange
SF- Spackle Flange
NF- Flangeless4
LED
RGB LED10
RGBX- RGB LED with DMX Controller
Custom Output
CL_____- Specify color temp. and lumens/ft. (i.e. CL35300)
CW____- Specify color temp. and wattage/ft. (i.e. CW407)
(Specify lumens/watts between standard offering listed above.
Lumens are specified per color temp.)
Individual Units2
2- 2’, 23” (584.2mm) fixture2
3- 3’, 35” (889mm) fixture2
4- 4’, 47” (1,193.8mm) fixture2
6- 6’, 71” (1,893.4mm) fixture2
8- 8’, 95” (2,413mm) fixture2
QS- Quick Ship13
CP- Chicago Plenum
GLR- Internal Fast blow fuse
LGR- Low Glare Reflector12
C90I- 90˚ Inside Corner7,11
C90O- 90˚ Outside Corner7,11
C45I- 45˚ Inside Corner7,11
C45O- 45˚ Outside Corner7,11
EF- End Filler8
SW- Step Switching
W- Matte White
S- Metallic Silver (rails only)9
BL- Textured Black (rails only)9
GR- Graphite (rails only)9
BR- Bronze (rails only)9
CC- Custom Color (rails only)9
Continuous Runs3
xx’-Specify row length to 1’ (304.8mm)
increments
See back page for mounting detail. 2Individual units shipped with end plates uninstalled. 3Continuous runs made up of both even and odd length fixtures. Designed to fall on-grid. 4NF to be utilized for metal
pan / millwork ceiling. 5Some Edge configurations will not accommodate all electrical options. Consult factory. 6Integral battery packs with remote test switch are provided with 1B option. Available in 4’ or
longer lengths. 7See back page for corner details. 8End Filler option used for fitting fixture into odd lengths. Filler is non-illuminated. Left and right end filler provided whe EF specified. 9Custom Color will be
on fixture rails only. 10Osram/Sylvania Color Changing RGB LED and components are for accent or decorative lighting and does not provide room illumination. See back page for more information. 11Submittal
drawings required. 12Low Glare Reflector (LGR) required on any layout with inside corner. LGR softens glare and changes polar cuvre and does effect lumen out put and efficacy, see back page for photometry.
13
Includes EVL, EVLS, all sizes, continuous runs, G1G and FLF mounts, UNV, 120 or 277 voltage, std white finish, 1C, 1D, and 1B circuiting, Chicago plenum, and GLR.
1
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
March 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previous printed or electronic versions.
PHOTOMETRICS
EV_L
873
720
655
540
437
360
218
180
Test #: ITL84679
Part #: EVL-35HO-4
Lumens per watt: 66
Total Delivered Lumens: 1592
Test #: ITL84682
Part #: EVL-35HO-4-LGR
Lumens per watt: 57
Total Delivered Lumens: 1376
EV3WG
INDIVIDUAL AND CONTINUOUS RUN MODULES 1
1” Grid Mounting Options
23" (584.2mm)
G1
G1
2'
9/16” Grid Mounting Options Screw Slot and 9/16” Mounting
Flange Detail
G9
FL
G9
GS
GS
Non-Flange
NF
Spackle Flange
SF
(1) module per 2' unit
35" (889mm)
3'
71” (1893.4mm) or 72” (1828.8mm)
Specify
(1) module per 3'
unit G1 in Mounting section
of part #.
47” (1193.8mm) or 48” (1219.2mm)
Specify G9 in Mounting section
of part #.
6'
Specify GS in Mounting section
(2) modules per 6' unit
of part #.
Specify FL of
part #.
Specify NF of
part #.
95” (2413mm) or 96” (2438.4mm)
Specify SF of
part #.
8'
4'
(2) modules per 8' unit
(1) module per 4' unit
1Acoustical Grid Ceiling and Inaccessible Ceilings available as individual units or continuous rows. Individual units and rows are available for on-grid installation with acoustical ceilings.
MOUNTING
1” Grid Mounting Options
G1
G1
Specify G1 in Mounting section
of part #.
9/16” Grid Mounting Options
G9
G9
Specify G9 in Mounting section
of part #.
APPLICATION GUIDELINES
Screw Slot and 9/16” Mounting
GB
GS
Flange Detail
GS
Specify GS in Mounting section
of part #.
Non-Flange
FL
NF
Specify FL of
part #.
Specify NF of
part #.
Spackle Flange
SF
Specify SF of
part #.
INSTALLATION
Reflector
Low Glare Reflector
Outline easily installs into acoustical grid and inaccessible ceiling. Install wall rail onto wall and
hook fixture onto rail. Tie off fixture to structure. MUST BE INSTALLED PRIOR TO CEILING
INSTALLATION. See installation instructions for detailed information.
CORNERS
18”-20” Illumination
45° Inside
45° Inside
90° Inside
End Filler
5° Outside
45° Outside
90° Outside
90° Outside
Outline is designed to install flush against
the wall. MUST BE INSTALLED PRIOR
TO CEILING INSTALLATION. See installation instructions for detailed information.
90° Inside
Pinnacle Lighting’s Outline is a complete perimeter lighting solution. The inside, outside corners,
and end fillers allow designers to Outline a space. The 45 degree and 90 degree corners allow for
+/- 5 degrees of adjustability to accommodate any wall imperfections. Specify runs to the nearest
foot and non-illuminated corners are slid into place to finish the perimeter lighting. Minimum
distance for corners is 5-1/2” from the wall, with a max of 12” away from the wall. The End Fillers
have a maximum
of 6” per end.
See installation
instructions
for detailed information.
End Filler
Inside
Corner
Outside Corner
Detail
Detail
Detail
Pinnacle Architectural Lighting 12655 East 42nd Avenue, Suite 50 Denver, CO 80239
Phone 303.322.5570
Fax 303.322.5568 www.pinnacle-ltg.com
© 2016 Pinnacle Architectural Lighting®
March 2016
Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacle-ltg.com are the most recent version and supersede all other previously printed or electronic versions.
Edge Evolution Outline
Row layout with End Fillers
Edge Evolution Outline end fillers allow for wall-to-wall fixture installation. The fillers are installed to the end of the row filling the gap between the fixture end and the
wall. End fillers are designed to be installed at the beginning and end of the row for optimal light distribution along the wall. Below are typical rows built of standard
fixture lengths with end fillers at each end. The end fillers can increase a row length between 1” to 12” on either side with 1” to 6” being the optimal length to either end.
When ordering rows with end fillers, specify the illuminated row length in the LENGTH section of the part number and EF in the OPTIONS section of the part number for the
End Fillers. Sample catalog #; EVL-30-24-G1-120-1D-W-EF
Nominal Fixture Lengths
Actual Fixture Lengths
Illuminated
Length
2’
23”
3’
35”
4’
47” or 48”
5’
59”
Row Layout with End Fillers
2’
EF
3’
EF
4’
EF
5’
EF
6’
EF
7’
EF
8’
EF
9’
EF
72”
10’
EF
72”
11’
EF
96”
12’
EF
96”
13’
EF
14’
EF
96”
15’
EF
96”
16’
EF
96”
17’
EF
96”
72”
18’
EF
96”
72”
19’
EF
96”
96”
20’
EF
96”
96”
21’
EF
96”
22’
EF
96”
96”
23’
EF
96”
96”
24’
EF
96”
96”
25’
EF
96”
96”
23”
EF
EF
35”
47”
EF
59”
EF
71”
EF
48”
35”
EF
95”
EF
35”
EF
47”
72”
EF
35”
EF
47”
48”
EF
35”
EF
71”
EF
48”
35”
EF
95”
EF
35”
EF
47”
72”
EF
35”
EF
47”
EF
48”
PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239
35”
EF
71”
EF
48”
35”
EF
95”
72”
Ph 303.322.5570
EF
35”
Fax 303.322.5568
EF
6’
71” or 72”
Min.
Length
Optimal
Length
Max.
Length
2’-1”
2’-11”
3’-11”
3’-1”
3’-11”
4’-11”
4’-1”
4’-11”
5’-11”
5’-1”
5’-11”
6’-11”
6’-1”
6’-11”
7’-11”
7’-1”
7’-11”
8’-11”
8’-1”
8’-11”
9’-11”
9’-1”
9’-11”
10’-11”
10’-1”
10’-11”
11’-11”
11’-1”
11’-11”
12’-11”
12’-1”
12’-11”
13’-11”
13’-1”
13’-11”
14’-11”
14’-1”
14’-11”
15’-11”
15’-1”
15’-11”
16’-11”
16’-1”
16’-11”
17’-11”
17’-1”
17’-11”
18’-11”
18’-1”
18’-11”
19’-11”
19’-1”
19’-11”
20’-11”
20’-1”
20’-11”
21’-11”
21’-1”
21’-11”
22’-11”
22’-1”
22’-11”
23’-11”
23’-1”
23’-11”
24’-11”
24’-1”
24’-11”
25’-11”
25’-1”
25’-11”
28’-11”
www.pinnacle-ltg.com
Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs.
8’
95” or 96”
March 2016
© 2016 Pinnacle Architectural Lighting™
Edge Evolution Outline
Row layout with End Fillers
PLAN VIEW
45° Inside
End Filler
90° Inside
45° Outside
90° Outside
45° Inside
45° Outside
90° Inside
Connector
Part
Number
Min.
Length
Max.
Length
End Filler
EF
1”
12”
45° Outside Corner
C45O
3/8”
9-11/16”
Begining of Row
90° Outside C45I
45° Inside Corner
4-1/4”
11-5/8”
End Filler
90°Inside Corner
C90I
7”
13”
90° Outside Corner
C90O
0”
9-1/2”
End Filler
End Fillers - Designed to be adjustable to
allow a standard fixture to fit into a wall-towall opening. ie. If you have an opening that
is 51” order a 4’ (47”) fixture and End Fillers
to fill in 2” inches on either side.
Outside Corners - Designed to go around
outside corners allowing you to light a
straight wall turn a corner and light another
wall. (Numbers
shown
Joining
Fixture are wall dimension)
Inside Corners - Designed to go into inside
corners allowing you to light a straight wall
turn a corner and light another wall.
Rough in for outside corner is from begining of
row length to far end of joining fixture.
Begining of Row
Joining Fixture
PINNACLE ARCHITECTURAL LIGHTING™ 12655 East 42nd Avenue, Suite 50 Denver, Colorado 80239
Ph 303.322.5570
Fax 303.322.5568
www.pinnacle-ltg.com
Shown are typical configurations utilizing standard product, and may not produce optimal lighting effects using Max. Length layouts will result in dark spots at the ends of your runs.
March 2016
© 2016 Pinnacle Architectural Lighting™
Download