PRODUCT NEWS Product Discontinuation Notices April 1, 2009 Photoelectric Sensors No.2009125E Discontinuation Notice of photoelectric Sensor E3X-NH series Product Discontinuation Recommended Replacement E3X-SD series E3X-DA-S series E3X-NH series Discontinuation date : The end of March, 2010 Caution on recommended replacement 1) When it is substituted by the E3X-SD series, the residual voltage of the control output becomes it from 1 V max. to 1.5 V max. 2) When Auto-tuning (Automatic Sensitivity Compensation) is used, E3X-DA[]1AT-S with the ATC function is recommended substitute. 3) When timer other than 10 ms are necessary at E3X-NH21 / 51, E3X-DA[]1-S with the variable timer function is recommended substitutes. Difference from discontinued product Body Color Dimen sions E3X-SD -- * E3X-DA-S -- * Model ** * -- Wire connection Mounting Dimensions Charact eristics Operation ratings Operation methods * * * * -- * * * * -- : Fully compatible : The change is a little/Almost compatible : Not compatible : No corresponding specification OMRON Corporation Industrial Automation Company Product Discontinuation and recommended replacement Product discontinuation Model Product code E3X-NH11 2M E3X-NH11 5M E3X 1052E E3X 1056H E3X-NH41 2M E3X-NH41 5M E3X 1059B E3X 1067C Recommended replacement selection condition When Auto-tuning is unnecessary Recommended replacement Model Product code E3X-SD11 2M E3X 7038B E3X-DA11AT-S E3X 1229C 2M E3X-SD41 2M E3X 7039M E3X-DA41AT-S E3X 1229C 2M E3X-SD11 2M E3X 7038B E3X-DA11-S 2M E3X 1181E E3X-DA11-S 5M E3X 1208M E3X-DA11AT-S E3X 1229C 2M E3X-SD41 2M E3X 7039M E3X-DA41-S 2M E3X 1187D E3X-DA41-S 5M E3X 1512H E3X-DA41AT-S E3X 1229C 2M When Auto-tuning is necessary When Auto-tuning is unnecessary When Auto-tuning is necessary When the timer is used with 10ms E3X-NH21 2M E3X-NH21 5M E3X 1061D E3X 1066E E3X-NH51 2M E3X-NH51 5M E3X 1062B E3X 1068A E3X-NH41-M1J 0.3M E3X 1073H When the timer is used excluding 10ms When the timer is used excluding 10ms and Auto-tuning is unnecessary When the timer is used with 10ms When the timer is used excluding 10ms When the timer is used excluding 10ms and Auto-tuning is unnecessary - None - Body color Product discontinuation E3X-NH series Recommendable replacement E3X-SD / DA-S series Case ; Light gray Black Product discontinuation Recommendable replacement E3X-SD / DA-S series Dimensions E3X-NH series E3X-SD series Threshold indicators (red) Operation indicator (orange) a* 7 A *1 Operation indicator 4-dia. vinyl-insulated round cable with 3 conductors* (Conductor cross section: 0.2 mm2; Insulator diameter: 1.1 mm), Standard length: 2 m. * The mounting bracket can be attached to this side. Two, 2.4 dia. Incident level indicators (green) 59 10 6 3 Two, 2.4 dia. 38.6 5.3 32.5 8 10.7 64.3 10 Mounting Holes 10.75 0.2 8 Two, M3 31.5 9.9 4.1 2.4 16 34.8 22.4 13 Two, 3.2-dia. holes 4 Mounting bracket (removable), stainless steel (SUS 304) 10.7 10.75 4.1 22.4 13 2.4 16 4 34.8 Mounting bracket (E39-L143) (Order separately) Stainless steel (SUS304) Two, 3.2-dia. holes 22.4 16 4.4 3.4 3.4 22.4 4.4 *1. The mounting bracket can also be used on side A. *2. There is no hole for E3X-NA@F models. Two, mounting holes 16 4.4 2 16 Hole for optical communications *2 3.4 Dimensions Product discontinuation Recommendable replacement E3X-SD / DA-S series E3X-NH series E3X-DA-S series Operation indicator Main display Round ( ): Power tuning indicator Oblong ( ): Operation indicator for channel 2 Vinyl-insulated round cable Standard length: 2 m* Sub-display Wire Connection Product discontinuation Recommendable replacement E3X-SD / DA-S series E3X-NH series E3X-NH11 / NH21 8-level incident 13-level threshold level indicators indicators (green) (red) E3X-SD11 Brown Operation indicator (orange) Brown Black Photoelectric Sensor main circuit Load Photoelectric Sensor main circuit Control output Load Orange Alarm output* 1 Operation indicator (orange) 12 to 24 VDC Load * Black 4 Control output Blue 12 to 24 VDC Blue 3 E3X-NH41 / NH51 8-level incident 13-level threshold level indicators indicators (green) (red) E3X-SD41 Operation indicator (orange) Brown Brown Photoelectric Sensor main circuit Control output Black Alarm Load output* Orange Operation indicator (orange) 12 to 24 VDC Load 1 Photoelectric Sensor main circuit * Black Control output 4 12 to 24 VDC Load Blue Blue 3 E3X-DA11-S Display Power tuning indicator (orange) Operation indicator (orange) Brown Black Photoelectric Sensor main circuit Load Control output 12 to 24 VDC Blue 3 Wire Connection Product discontinuation Recommendable replacement E3X-SD / DA-S series E3X-NH series E3X-DA41-S Operation indicator (orange) Display Brown Power tuning indicator (orange) Photoelectric Sensor main circuit Black Control output 12 to 24 VDC Load Blue E3X-DA11AT-S Display Operation indicator Operation indicator (orange) (orange) ch 2 ch 1 Brown Load Black Control output 1 Orange Photoelectric Sensor main circuit Load 12 to 24 VDC Control output 2 Blue E3X-DA41AT-S Display Operation indicator Operation indicator (orange) ch 2 (orange) ch 1 Brown Control output 1 Photoelectric Sensor main circuit Black Orange Control output 2 Blue 12 to 24 VDC Load Load Mounting Operation dimensions Characteristic Product discontinuation E3X-NH series 1) Din track mounting 1) Din track mounting 2) Screw mounting 2) Screw mounting 2-M3 2-M3 16 4 Recommendable replacement E3X-SD / DA-S series 16 Characteristic Model Item NPN output PNP output Light source (wavelength) Power supply voltage Power consumption Current consumption Control output Response time Sensitivity setting Timer function Display Digital display E32Sensing TC200 Distance E32DC200 Product discontinuation E3X-NH11 E3X-NH21 E3X-NH41 E3X-NH51 E3X-SD11 E3X-SD41 Red LED (680 nm) Red LED (620 nm) Recommended replacement E3X-DA11-S E3X-DA11AT-S E3X-DA41-S E3X-DA41AT-S Red LED (635 nm) 12 to 24 VDC ±10 %, ripple (p-p) : 10 % max. 960 mW max. 1080 mW max. 960 mW max. (current consumption : (current consumption : (current consumption : 40 mA max. 40 mA max. 45 mA max. at power supply at power supply at power supply voltage of 24 VDC) voltage of 24 VDC) voltage of 24 VDC) Load power supply voltage : Load power supply Load power supply voltage : 26.4 VDC; 26.4 VDC; voltage : 26.4 VDC; NPN / PNP open collector; open collector; open collector; load current : 50 mA max.; load current : 50 mA max.; load current : residual voltage : 1 V max. residual voltage : 1 V max. 50 mA max.; residual voltage : 1.5V max. Super-high-speed mode; Super-high-speed mode; Operate or reset : Operate or reset : NPN Operate or reset : 1 ms max. 200 µs max. Operate : 48 µs, 130 µs : 50 µs reset High-speed Mode; PNP Operate or reset : Operate : 53 µs, 250 µs : 55 µs reset Standard mode; Operate or reset : 1 ms High-speed Mode : Operate or reset : High-resolution mode; 250 µs Operate or reset : 4 ms Standard mode : Operate or reset : 1 msc; Operate or reset : 4 ms Teaching or manual method None OFF-delay ON / OFF-delay timer : Select from OFF-delay, ON-delay, one-shot, timer 10 ms (each fixed) or ON-delay + OFF-delay timer 1 ms to 5 s 5,10,20,40, (1 to 20 ms set in 1-ms increments, 60,80,100 ms 20 to 200 ms set in 5-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1 s-increments) Operation indicator Operation indicator for Operation indicator (orange LED), Operation indicator (orange) channel 1 (orange) 8-level incident level indicator (orange LED), Incident level indicators Power Tuning indicator Operation indicator for (green LED), (green LED) (orange) channel 2 (orange) 13-level threshold indicator (red LED) None Incident level Select from incident level + threshold or other 6 patterns 75 mA max. 400 mm 760 mm (Standard mode) 150 mm 300 mm (Standard mode) Operating :-25 °C to 55 °C Storage :-40 °C to 70 °C (with no icing or condensation) Ambient temperature Ambient humidity Degree of protection MateCase rials Cover Operating : Operating : Groups of 1 to 3 Groups of 1 to 2 Amplifiers : Amplifiers : -25 °C to 55 °C -25 °C to 55 °C Groups of 3 to 10 Amplifiers : -25 °C to 50 °C Groups of 4 to 11 Groups of 11 to 16 Amplifiers : -25 °C to 45 °C Amplifiers : Storage : -30 °C to 70 °C -25 °C to 50 °C (with no icing or condensation) Groups of 12 to 16 Amplifiers : -25 °C to 45 °C Storage : -30 °C to 70 °C (with no icing or condensation) Operating and storage : 35 % to 85 % (with no condensation) IEC 60529 IP50 (with Protective Cover attached) Polybutylene terephthalate (PBT) Polycarbonate (PC) 5 Operation ratings Operation Characteristic Product discontinuation Recommendable replacement E3X-SD / DA-S series E3X-NH series Parallel Operating Range (Typical) E3X-SD series Parallel Operating Range (Typical) E32-TC200 Distance Y (mm) Distance Y (mm) E32-TC200 300 X Y 200 100 0 0.2 0.4 0.6 0.8 1 -200 -300 0.6 0.8 1 Y 100 50 200 300 400 Distance X (mm) 150 X Y 100 50 0 100 200 -50 -100 -100 -150 -150 300 400 Distance X (mm) E3X-DA-S series Parallel Operating Range (Typical) Operating Range (Typical) 6 1.2 Distance X (m) E32-DC200 X Distance Y (mm) Distance Y (mm) E32-DC200 -50 0.4 Operating Range (Typical) 150 100 0.2 -100 -300 0 Y 100 -200 Operating Range (Typical) X 200 0 1.2 Distance X (m) -100 300 Operation methods Operation Characteristic Product discontinuation E3X-NH series Operation with slide switch and push-button. Recommendable replacement E3X-SD / DA-S series Operation with slide switch and push-button. Accessories Operation Characteristic Product discontinuation E3X-NH series Recommendable replacement E3X-SD / DA-S series 1) Instruction Manual 1) Instruction Manual 2) Mounting Bracket ; E39-L143 2) Mounting Bracket is not attached. Please buy optional E39-L143 when the Mounting Bracket is necessary. 7