AirCell® Catalog - Trilogy Communications, Inc.

advertisement
AirCell
®
®
Wireless Cabling Technology
TABLE OF CONTENTS
I. General Information
II. Coaxial Cable Selection Guide
III.Transline Cables
A. Overview and Product Description
B. Cable Selection Guide
C. Specification Sheets
D. Accessory Selection Information
Pages
1-4
5-8
9-13
14-15
16-23
24-28
Transline Cable
IV. Radiating Cables
A. Overview and Product Description
B. Cable Selection Guide
C. Specification Sheets
D. Accessory Selection Information
29-33
34-35
36-43
44
V. Plenum Cable
A. Overview and Product Description
B. Cable Selection Guide
C. Specification Sheets
45-48
49
50-54
VI. Connectors and Tools
A. Connectors
B. Connector Selection Guide
C. Connector Installation Instructions
D. Coring Tools
E. Weather Proofing Instructions
55-57
58
59-67
68
69
VII. Cable Assemblies
70-71
VIII. Hardware and Accessories
72-83
IX. Ordering Information
Terms & Conditions
Credit Form
Warranty
84
85-86
87
Radiating Cable
Plenum Cable
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
GENERAL INFORMATION
About The Company
The Company
In 1985, on the brink of the information age Trilogy Communications Inc. was formed and began developing and
marketing MC2, the first low-loss air-dielectric coaxial cable. Trilogy quickly established itself as a pacesetting
force in the communications industry.
Trilogy flourished almost immediately, becoming the world’s leading manufacturer of low-loss coaxial cable. This
includes two plants housing state-of-the-art production and inventory management systems. Trilogy’s ISO-9001
registered corporate headquarters and manufacturing facilities are located near Jackson, Mississippi.
To date, over three billion feet of our air-dielectric coaxial cable have been installed worldwide, and our products
are sold in more than 40 countries.
The Products
Trilogy was the first company to offer an exceptionally high quality, low-loss coaxial cable. Its MC2 trunk and feeder
and its MVP drop cables for telecommunications applications are known around the world.
To meet the wireless communication market’s exploding needs,Trilogy has introduced a product line under the
trade name AirCell®. This line of patented, high-performance, low-loss, 50 and 75 Ohm coaxial cables has been
developed exclusively for the wireless communications market and employs the same winning performance and
reliable features as Trilogy’s flagship product, MC2.
Pearl, Mississippi
1
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
GENERAL INFORMATION
About The Company
The AirCell® name is derived from the patented air-dielectric design. Dry air is enclosed in hermetically sealed
polyethylene chambers that bond 100% from center conductor to outer conductor. The air chambers are formed
by regularly spaced discs, which provide structural integrity to the cable. The outer conductor sheath is totally
bonded to the polyethylene structure. This unique air-dielectric design gives AirCell® coaxial cable strength, flexibility,
durability, superior electrical performance, and unparalleled protection without the need for pressurization, making
it the best cable in the industry. AirCell® cables are the industry standard of excellence for wireless applications
such as PCS, cellular, paging, and ESMR applications.
The AirCell® product family consists of all the cables, connectors, accessories, and hardware designed to provide
optimum electrical performance for outdoor site installations, indoor riser and plenum applications, and distributive
radiating communications systems.
ISO-9001 Certified
All of Trilogy’s manufacturing facilities have successfully completed the requirements of ISO-9001, which is the
internationally recognized standard for quality systems. This certification reflects the constant efforts and desire
of Trilogy employees to offer the best quality products and services in the cable industry.
The Commitment
With the help of our many customers,Trilogy has been able to build a reputation as a leader in the telecommunications
industry. Through superior quality, innovative technology, and exceptional customer service,Trilogy Communications
is now committed to becoming your premier wireless communications cable supplier.
Flowood, Mississippi
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
2
GENERAL INFORMATION
Transline Cable
AirCell® is Trilogy’s brand name for the highest quality, best performing, and most reliable coaxial cable in the
industry. A line of trademarked, high performance, low-loss 50 and 75 Ohm coaxial cables, AirCell® is designed
for both indoor and outdoor applications. The AirCell® product line includes Transline, Radiating, and Plenum
cables.
AirCell® Transline Cable
Trilogy’s AirCell® Transline cables are the waterproof,
air-dielectric answer for your PCS, cellular, paging,
broadcast, microwave, and ESMR applications. These
cables feature a non-pressurized, air-dielectric design
that provides unparalleled protection against water
migration, and Trilogy backs up this design with the
industry’s best warranty–15 years, including cable and
installation. AirCell® Transline cables also deliver superior
electrical performance, combining low attenuation
with the highest attainable velocity of propagation. The
durable mechanical properties of AirCell® Transline
cables ensure superior performance, ease of installation,
and a long service life.
AirCell® Transline cables feature many
advantages, including:
•Low Attenuation
•No Intermodulation Generation
•Lightweight Construction for Ease of Handling
•Strong, Rugged Design and Flexibility
•High Power Handling Capability
•Weatherproof for Endurance in Outdoor Applications
•Low VSWR Performance
•Solid Outer Conductor for Total Shielding
•Ease of Connectorization & Installation
•15-year Warranty Against Water Migration
3
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
GENERAL INFORMATION
Radiating & Plenum Cable
AirCell® Radiating Cable
AirCell® Plenum Cable
Trilogy’s AirCell® Radiating cables are the most effective
way to deliver clear, reliable broadband communications
in restricted areas such as buildings, subways, mines, and
tunnels. Engineered for low attenuation and optimal
coupling loss, the unique AirCell® design is the best
performer in the industry. Since less in-line amplification
is required, a larger area can be covered with fewer active
devices. In addition, our patented, dual continuous slot
design provides consistent signal strength along the length
of the cable. Let Trilogy’s AirCell® Radiating cable help
you expand your wireless communications and reach
more subscribers.
Trilogy’s AirCell® Plenum cables are designed for networking applications such as LAN’s and WAN’s, wireless PBX’s,
cellular, PCS, and paging. The unique design of Trilogy’s
Plenum cable eliminates the use of Teflon® while producing
superior electrical performance. AirCell® Plenum cables
have been specifically engineered for use in plenum air
spaces where the most stringent fire codes are in place.
A flexible corrugated design ensures that Trilogy’s AirCell®
plenum cable can navigate the tight bending requirements
of an in-building system. In addition, our high performance
connectors attach easily, and Trilogy’s unique air-dielectric
design provides the lowest attenuation available. Whether
it is used for WAN/LAN, distributed communications,
or high-speed data, AirCell® Plenum cable has all the
features to make your system installation easy and
successful. AirCell® Plenum cable is available in both
radiating and non-radiating versions.
AirCell® Radiating cables offer many
benefits to your applications:
•Multiband Capabilities
•Uniform Coverage
•Low Attenuation and Optimal Coupling Loss
•Low VSWR
•Superior Durability
•Ease of Connectorization and Installation
The main features of AirCell® Plenum are:
•Low Attenuation
•Flexibility
•Superior Durability
•Ease of Connectorization
•UL 910 Plenum-rating
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
4
TRANSLINE CABLE
Table Of Contents
III.AirCell® Transline Cables
9
Pages
A) Overview and Product Description
10-13
B) Cable Selection Guide
14-15
C) Specification Sheets
16-23
D) Accessory Selection Information
24-28
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Overview
Trilogy’s AirCell® cables embody innovative, waterproof air-dielectric design, consistent manufacturing, and quality
assurance techniques in accordance with ISO-9001 procedures. The result is a coaxial cable with superior
electrical and mechanical performance that completely eliminates water migration.
Trilogy’s AirCell® Transline cable is designed for base station applications and is field proven in cellular, PCS,
ESMR, paging, broadcast, and microwave applications. AirCell® Transline cables are available with impedances of 50
Ohms in 1/2", 5/8", 7/8", 1-1/4", and 1-5/8" sizes and with impedances of 75 Ohms in 1/2", 5/8", and 7/8" sizes.
To accompany our cables,Trilogy offers a complete line of connectors, accessories, and cable assemblies for all
your wireless application needs.
AirCell® Transline cable is designed for the following applications:
PCS, Cellular, and Paging
Trilogy’s cables and connectors are ideally suited to the high performance requirements of cellular and PCS
applications. Transline cable’s excellent insertion loss,VSWR, and intermodulation characteristics enhance both
digital and analog systems. Water migration problems are non-existent because of the unique AirCell® design.
Trilogy’s high performance connectors are easily attached to form a solid watertight assembly that will provide
trouble free communications for the life of your system.
Broadcast
Having the easiest installation in the industry makes AirCell® Transline cable the best choice for radio and television
broadcast antenna feeders and for AM, FM, shortwave,VHF, and UHF frequencies.
Microwave
Trilogy’s AirCell® Transline cable is perfect for all private and PTF microwave applications. Transline cable’s superior
VSWR performance has been specifically tested for microwave applications. The cable’s strong, rugged design as
well as flexibility makes it easy to install in any climate, and its weatherproof properties result in a life
expectancy of over 15 years.
Enhanced Specialized Mobile Radio (ESMR)
The low attenuation and high shielding effectiveness of AirCell® Transline make it an ideal replacement for braided
cable. The low insertion loss of Trilogy’s AirCell® Transline cables typically provides double the coverage area for the
same transmit power, or it can provide coverage to the same area and use lower transmit power.
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
10
TRANSLINE CABLE
Overview
Level of Fire Retardancy
The standard Transline cable construction uses a weather-resistant, black polyethylene jacket suitable for indoor,
outdoor, or underground installations. For additional requirements regarding flame retardancy, AirCell® Transline
cables are available with a non-halogenated, flame retardant jacket, which meets the most stringent fire
retardancy requirements of UL, NEC, IEC, MSHA, and NES as shown below.
AirCell® Transline Fire Retardancy Ratings*
Vertical Wire Flame Test
Vertical Tray Flame Test
Riser Cable Test
Vertical Single Cable Test
Halogen Acid Gas Test
Acid Gas Test
Approved for use in Underground
Mines as Signal Cable
USA
Europe
UL VW1/CMX
UL 1581/CATV
UL 1666/CMR
IEC 332-1
IEC 754-1
IEC 754-2
MSHA 30 CFR
*Ratings based on cable diameters and construction
Benefits of AirCell® Transline Cable
Our AirCell® Transline cable’s superior air-dielectric design and our manufacturing experience guarantee a
technically superior product with the following advantages:
Low VSWR
The unique design and precise manufacturing processes of AirCell® Transline cables offer the lowest VSWR
performance in the industry.
Low Attenuation
The patented air-dielectric design and 91% velocity of propagation of AirCell® Transline cables provide the
lowest attenuation available, which results in highly efficient signal transfer in your RF system.
High Power Capability
Due to their low attenuation and excellent thermal conductivity, AirCell® Transline cables offer a high
average power handling capability that exceeds the requirements of PCS, cellular, paging, and ESMR
applications.
Weatherproof for Stability in Outdoor Applications
AirCell® Transline cables are perfect for outdoor applications because they do not allow water migration. The
hermetically sealed, fully bonded design of AirCell® Transline cable prohibits water migration through the
cable. Trilogy guarantees this with the industry’s best warranty–15 years including cable and installation.
11
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Overview
AirCell® Transline cables are also protected with a rugged, black polyethylene jacket that provides abrasion
resistance and complete environmental protection.
Superior Durability
AirCell® Transline cables have superior longitudinal strength, crush resistance, and flexibility. This rugged construction
ensures that installations are trouble free and that in-service life and system reliability is maximized.
Total Shielding
The solid outer conductor of AirCell® Transline cable creates a continuous RFI/EMI shield that eliminates system
interference.
Minimized Intermodulation Generation
AirCell® Transline cable’s solid inner and outer conductors and its silver-plated connector junction virtually
eliminate intermodulation interference in applications such as PCS, cellular, and paging.
Flexibility
The totally bonded design of AirCell® Transline cable offers excellent flexibility, making them suitable for tower
and base station installations where multiple bends are needed. AirCell® Transline cables can be easily routed
because of their durability and lower bending moments.
Ease of Connectorization
Trilogy’s AirCell® Transline cables have the fastest field connectorization time in the industry. By using the AirCell®
all-in-one prep tool (see p.68 ), installing connectors on AirCell® Transline cables can be accomplished in one
easy step that requires less than two minutes. In addition, our connectorization does not require soldering or
removal of the center conductor foam. Together Trilogy’s cable and connectors are an unbeatable match that
optimize entire system performance.
Complete Product Line
AirCell® Transline cables are complemented by our compatible, high-quality connectors, hangers, grounding
systems, and other installation accessories to form a complete RF transmission line system. This means that
Trilogy Communications meets all of your transmission line needs. At Trilogy, all of our cable components are
engineered to work together. Our quality products are delivered fast and on time –saving you time and money.
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
12
TRANSLINE CABLE
Product Description
Transline Premium Performance Cable
Center Conductor
The center conductor of the cable consists of either a pure copper
tube or a copper-clad electrical grade aluminum wire with 10%
copper by volume which conforms to ASTM B-566, class 10A. This
lightweight conductor provides both high quality and strength.
Conductor Adhesive
The center conductor is coated with a proprietary adhesive to secure
the dielectric discs to the center conductor. This adhesive ensures
that the discs are bonded to the center conductor, which prevents
moisture migration and center conductor pull-out. In addition, this
material can easily be removed to facilitate quick connector installation.
Dielectric Discs
The dielectric discs are injection molded from virgin polyethylene
(ASTM D-1248). These discs are regularly spaced to provide structural
integrity while minimizing attenuation.
Dielectric Tube
The dielectric tube is extruded over the dielectric discs using a
virgin polyethylene (ASTM D-1248). The tube and disc materials
are bonded together, forming hermetically sealed chambers that
provide a barrier to water penetration. Since this type of dielectric
structure contains a high percentage of air, the cable attenuation
is the lowest available.
Dielectric Adhesive
The dielectric tube adhesive is composed of a proprietary polymer
that is co-extruded over the dielectric tube. The adhesive bonds
the inner dielectric tube to the aluminum outer conductor, resulting
in a strong, durable composite structure.
Aluminum Outer Conductor
The outer conductor is a continuously formed and welded premium
grade aluminum tube. In-process monitoring assures weld integrity,
maintains proper aluminum thickness, and corrects physical dimensions. This conductor provides unsurpassed shielding, high crush
strength, and no intermodulation generation.
Jacket
A UV-stabilized, black, polyethylene jacket is standard (ASTM D-1248).
This jacket provides the strength and durability to meet the most
demanding conditions. Fire Retardancy: optional fire retardant jackets
are also available to meet more stringent requirements.
13
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
AirCell
TRANSLINE CABLE
®
Cable Specifications Summary
50 Ohm Transline, 1/2”, 7/8”, 1-1/4" and 1-5/8” (5/8”-size cable is also available upon request)
Cable Size
Jacketing
Black Polyethylene Jacket
Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1
Fire Retardant Jacket, IEC332-1, MSHA
Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,
IEC332-3C, UL 1685-12 (FT4/IEEE1202,
NFPA-130)
Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C,
UL-1666, CMR
Characteristics
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Cable Weight, lb/ft (kg/km)
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Impedance, Ohms
Velocity of Propagation
Maximum Frequency, GHz
Attenuation, dB/100 ft (dB/100 m)
100 MHz
150 MHz
450 MHz
894 MHz
960 MHz
1800 MHz
2000 MHz
2300 MHz
3000 MHz
Average Power Rating, kW
100 MHz
150 MHz
450 MHz
894 MHz
960 MHz
1800 MHz
2000 MHz
2300 MHz
3000 MHz
½”
Product Code
AT012J50
7/8”
Product Code
AT078J50
1-1/4”
Product Code
AT114J50
1-5/8”
Product Code
AT158J50
AT012FX50
AT078FX50
AT114FX50
AT158FX50
AT012F50
-
-
-
AT012FV50
AT078FV50
AT114FV50
AT158FV50
AT012R50
AT078R50
AT114R50
AT158R50
0.470 (11.94)
0.510 (12.95)
0.642 (16.30)
0.12 (0.18)
2 (50.8)
6 (152)
465 (211)
62 (1.11)
50
91%
11
0.968 (24.58)
1.012 (25.70)
1.142 (29.01)
0.29 (0.43)
5 (127)
10 (254)
734 (333.6)
132 (2.36)
50
91%
5
1.480 (37.59)
1.524 (38.71)
1.654 (42.01)
0.53 (0.789)
6 (152.4)
15 (381)
1124 (511)
122 (2.18)
50
91%
3.4
1.871 (47.52)
1.888 (47.96)
2.035 (51.69)
0.70 (1.037)
8 (203)
20 (508)
1500 (682)
150 (2.68)
50
91%
3
0.68 (2.23)
0.84 (2.76)
1.49 (4.89)
2.15 (7.05)
2.25 (7.38)
3.16 (10.37)
3.38 (11.09)
3.61 (11.80)
4.29 (14.07)
0.33 (1.08)
0.40 (1.31)
0.73 (2.40)
1.08 (3.54)
1.12 (3.67)
1.61 (5.28)
1.72 (5.64)
1.87 (6.14)
2.20 (7.22)
0.24 (0.79)
0.29 (0.95)
0.54 (1.77)
0.81 (2.66)
0.85 (2.79)
1.25 (4.10)
1.33 (4.36)
1.45 (4.76)
1.84 (6.04)
0.18 (0.61)
0.23 (0.76)
0.42 (1.39)
0.62 (2.04)
0.64 (2.13)
0.96 (3.02)
1.01 (3.34)
1.10 (3.61)
1.36 (4.46)
2.24
1.83
1.05
0.74
0.71
0.52
0.49
0.46
0.40
6.31
5.13
2.93
2.06
1.98
1.55
1.35
1.25
1.09
14.78
12.24
6.57
4.38
4.17
2.87
2.67
2.44
1.93
20.70
16.55
8.85
5.93
5.56
3.76
3.51
3.20
2.44
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
5/15
AirCell
TRANSLINE CABLES
®
Cable Specifications Summary
75 Ohm Transline
1/2"
5/8”
7/8”
Product Code
Product Code
Product Code
AT012J75
AT058J75
AT078J75
AT012FX75
AT058FX75
AT078FX75
AT012F75
-
-
AT012R75
AT058R75
AT078R75
Cable Size
Jacketing
Black Polyethylene Jacket
Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Fire Retardant Jacket, IEC332-1,
MSHA
Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,
IEC332-3C, UL-1666, CMR
Characteristics
Dia. Over Dielectric, in (mm)
0.470 (11.94)
0.712 (18.08)
0.961 (24.41)
Dia. Over Outer Conductor, in (mm)
0.510 (12.95)
0.760 (19.30)
1.015 (25.78)
Max. Dia. Over Jacket, in (mm)
0.652 (16.56)
0.892 (22.65)
1.147 (29.13)
Weight, lb/ft (kg/m)
0.10 (0.15)
0.20 (0.29)
0.35 (0.47)
Min. Bend. Rad. in (mm) – Single
2 (50.8)
3 (76.2)
8 (203)
Min. Bend. Rad. In (mm) – Multiple
6 (152)
8 (203)
10 (254)
Tensile Strength, lb (kg)
465 (211)
500 (227)
830 (377)
Flat Plate Crush, lb/in (kg/mm)
62 (1.11)
140 (2.50)
132 (2.36)
Impedance, Ohms
75
75
75
Velocity of Propagation
93%
93%
93%
Maximum Frequency, GHz
11
8
6
Attenuation, dB/100 ft (dB/100 m)
100 MHz
0.65 (2.13)
0.46 (1.51)
0.32 (1.05)
150 MHz
0.77 (2.53)
0.56 (1.84)
0.40 (1.31)
450 MHz
1.40 (4.59)
0.97 (3.18)
0.74 (2.43)
894 MHz
2.02 (6.63)
1.37 (4.49)
1.08 (3.54)
960 MHz
2.10 (6.89)
1.44 (4.72)
1.13 (3.71)
1800 MHz
2.86 (9.38)
1.95 (6.40)
1.62 (5.31)
2000 MHz
3.03 (9.94)
2.07 (6.79)
1.74 (5.71)
2300 MHz
3.26 (10.70)
2.29 (7.51)
1.89 (6.20)
3000 MHz
3.72 (12.2)
2.62 (8.59)
2.16 (7.09)
100 MHz
150 MHz
1.73
1.45
3.13
2.68
5.32
4.51
450 MHz
894 MHz
0.80
0.56
1.48
1.05
2.30
1.58
960 MHz
1800 MHz
0.53
0.39
1.00
0.74
1.51
1.06
2000 MHz
2300 MHz
3000 MHz
0.37
0.70
0.98
0.34
0.30
0.63
0.55
0.90
0.79
Average Power Rating, kW
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
5/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
50 Ohm Transline Cable, 1/2” – AT012J50/ AT012FX50/ AT012F50/ AT012FV50/ AT012R50
Description
Standard Cable
Product Number
1/2", Black Polyethylene Jacket
AT012J50
Fire Retardant Cable
1/2", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Fire Retardant Cable
AT012FX50
1/2”, Fire Retardant Jacket, IEC332-1,
MSHA
Fire Retardant Cable
1/2", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,IEC332-3C,
UL1685-12 (FT4/IEEE1202,NFPA-130)
Riser Rated Cable
1/2”, Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C,
UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
Bending Moment, ft.lb (N.m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
Recommended Install Temp., oF (oC)
Recommended Storage Temp., oF (oC)
Recommended Operating Temp., oF (oC)
AT012F50
AT012FV50
AT012R50
0.188 (4.78)
0.470 (11.94)
0.510 (12.95)
0.642 (16.30)
Copper-Clad Aluminum
Solid Aluminum
11
32
0.46 (1.51)
0.45 (1.48)
3.2
22.3 (73.16)
0.056 (0.184)
8
1.25 (19.0)
1.13 (24.3)
50
91%
2 (50.8)
6 (152)
0.12 (0.18)
7.5 (10.2)
465 (211)
62 (1.11)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.37
1.21
4.11
50
0.48
1.57
3.18
88
0.63
2.06
2.39
100
0.68
2.23
2.24
108
0.69
2.26
2.16
150
0.84
2.76
1.83
174
0.88
2.88
1.70
200
0.98
3.22
1.58
300
1.21
3.97
1.29
400
1.41
4.63
1.11
450
1.49
4.89
1.05
500
1.57
5.15
1.00
512
1.59
5.22
0.98
600
1.73
5.68
0.91
700
1.88
6.17
0.84
800
2.03
6.66
0.78
824
2.05
6.73
0.77
894
2.15
7.05
0.74
960
2.25
7.38
0.71
1000
2.29
7.51
0.70
1250
2.57
8.43
0.62
1500
2.85
9.35
0.57
1800
3.16
10.37
0.52
1900
3.27
10.73
0.50
2000
3.38
11.09
0.49
2300
3.61
11.80
0.46
3000
4.29
14.07
0.40
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
50 Ohm Transline Cable, 5/8” – AT058J50/ AT058FX50/ AT058FV50/ AT058R50
Description
Standard Cable
5/8", Black Polyethylene Jacket
Fire Retardant Cable
5/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Fire Retardant Cable
5/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,IEC332-3C,
UL1685-12 (FT4/IEEE1202,NFPA-130)
Riser Rated Cable
5/8”, Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C,
UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AT058J50
AT058FX50
AT058FV50
AT058R50
0.283 (7.9)
0.712 (18.08)
0.760 (19.30)
0.892 (22.65)
Solid Copper Tube
Solid Aluminum Tube
7
65
0.36 (1.18)
0.25 (0.82)
5
22.3 (73.16)
0.056 (0.184)
8
1.25 (19.0)
1.13 (24.3)
50
91%
3 (76.2)
8 (203)
0.25 (0.38)
21 (28.5)
920 (417)
140 (2.50)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.28
0.92
8.36
50
0.36
1.17
6.46
88
0.46
1.50
4.86
100
0.50
1.64
4.56
108
0.52
1.70
4.38
150
0.62
2.03
3.71
174
0.66
2.16
3.45
200
0.72
2.36
3.21
300
0.88
2.89
2.61
400
1.01
3.31
2.26
450
1.08
3.54
2.13
500
1.14
3.74
2.02
512
1.15
3.77
1.99
600
1.23
4.04
1.84
700
1.35
4.43
1.70
800
1.45
4.76
1.58
824
1.48
4.86
1.56
894
1.54
5.05
1.50
960
1.60
5.25
1.44
1000
1.64
5.38
1.41
1250
1.86
6.10
1.26
1500
2.07
6.79
1.15
1800
2.31
7.58
1.04
1900
2.39
7.84
1.01
2000
2.47
8.10
0.99
2300
2.72
8.92
0.92
3000
3.24
10.63
0.80
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
50 Ohm Transline Cable, 7/8” – AT078J50/ AT078FX50/ AT078FV50/ AT078R50
Description
Standard Cable
7/8", Black Polyethylene Jacket
Fire Retardant Cable
7/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Fire Retardant Cable
7/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,IEC332-3C,
UL1685-12 (FT4/IEEE1202,NFPA-130)
Riser Rated Cable
7/8”, Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C,
UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AT078J50
AT078FX50
AT078FV50
AT078R50
0.383 (9.73)
0.968 (24.58)
1.012 (25.70)
1.142 (29.01)
Solid Copper Tube
Solid Aluminum Tube
5
90
0.47 (1.54)
0.20 (0.64)
6.7
22.3 (73.16)
0.056 (0.184)
8
1.25 (19.0)
1.13 (24.3)
50
91%
5 (127)
10 (254)
0.29 (0.43)
26 (35.1)
734 (333.6)
132 (2.36)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.17
0.56
11.60
50
0.23
0.75
8.95
88
0.31
1.02
6.73
100
0.33
1.08
6.31
108
0.34
1.12
6.07
150
0.40
1.31
5.13
174
0.44
1.44
4.76
200
0.47
1.54
4.44
300
0.59
1.94
3.61
400
0.69
2.26
3.11
450
0.73
2.40
2.93
500
0.78
2.56
2.78
512
0.79
2.59
2.74
600
0.86
2.82
2.53
700
0.94
3.08
2.33
800
1.01
3.31
2.18
824
1.03
3.38
2.15
894
1.08
3.54
2.06
960
1.12
3.67
1.98
1000
1.15
3.77
1.94
1250
1.30
4.27
1.73
1500
1.45
4.76
1.57
1800
1.61
5.28
1.55
1900
1.67
5.48
1.53
2000
1.72
5.64
1.35
2300
1.87
6.14
1.25
3000
2.20
7.22
1.09
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
50 Ohm Transline Cable, 1-1/4” – AT114J50/ AT114FX50/ AT114FV50/ AT114R50
Description
Standard Cable
1-1/4", Black Polyethylene Jacket
Fire Retardant Cable
1-1/4", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Fire Retardant Cable
1-1/4", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,IEC332-3C,
UL1685-12 (FT4/IEEE1202,NFPA-130)
Riser Rated Cable
1-1/4”, Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,
IEC332-3C, UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AT114J50
AT114FX50
AT114FV50
AT114R50
0.590 (14.98)
1.480 (37.59)
1.524 (38.71)
1.654 (42.01)
Solid Copper Tube
Solid Aluminum Tube
3.4
211
0.30 (0.99)
0.12 (0.42)
9
22.3 (73.16)
0.056 (0.184)
8
1.25 (19.0)
1.13 (24.3)
50
91%
6 (152.4)
15 (381)
0.53 (0.789)
50 (67.5)
1124 (511)
122 (2.18)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.12
0.39
29.57
50
0.16
0.52
22.18
88
0.22
0.72
16.13
100
0.24
0.79
14.78
108
0.25
0.82
14.19
150
0.29
0.95
12.24
174
0.32
1.05
11.09
200
0.34
1.12
10.44
300
0.43
1.41
8.25
400
0.51
1.67
6.96
450
0.54
1.77
6.57
500
0.58
1.90
6.12
512
0.59
1.94
6.01
600
0.64
2.10
5.54
700
0.70
2.30
5.07
800
0.76
2.49
4.67
824
0.77
2.53
4.61
894
0.81
2.66
4.38
960
0.85
2.79
4.17
1000
0.87
2.85
4.08
1250
0.99
3.25
3.58
1500
1.11
3.64
3.20
1800
1.25
4.10
2.87
1900
1.29
4.23
2.76
2000
1.33
4.36
2.67
2300
1.45
4.76
2.44
3000
1.84
6.04
1.93
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
50 Ohm Transline Cable, 1-5/8” – AT158J50/ AT158FX50/ AT158FV50/ AT158R50
Description
Standard Cable
1-5/8", Black Polyethylene Jacket
Fire Retardant Cable
1-5/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Fire Retardant Cable
1-5/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,IEC332-3C,
UL1685-12 (FT4/IEEE1202,NFPA-130)
Riser Rated Cable
1-5/8”, Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1,
IEC332-3C, UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AT158J50
AT158FX50
AT158FV50
AT158R50
0.728 (18.49)
1.871 (47.52)
1.888 (47.96)
2.035 (51.69)
Solid Copper Tube
Solid Aluminum Tube
3
315
0.22 (0.72)
0.10 (0.33)
11
22.3 (73.16)
0.056 (0.184)
8
1.25 (19.0)
1.13 (24.3)
50
91%
8 (203)
20 (508)
0.70 (1.037)
60 (81)
1500 (682)
150 (2.68)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.09
0.33
39.16
50
0.13
0.43
30.16
88
0.17
0.57
24.87
100
0.18
0.61
20.67
108
0.19
0.64
20.00
150
0.23
0.76
16.55
174
0.25
0.82
12.65
200
0.27
0.89
14.09
300
0.33
1.10
11.19
400
0.39
1.29
9.47
450
0.42
1.39
8.85
500
0.44
1.46
8.31
512
0.45
1.49
8.19
600
0.49
1.62
7.46
700
0.54
1.78
6.80
800
0.58
1.93
6.26
824
0.59
1.97
6.24
894
0.62
2.04
5.93
960
0.64
2.13
5.56
1000
0.67
2.20
5.46
1250
0.75
2.47
4.75
1500
0.85
2.80
4.23
1800
0.96
3.02
3.76
1900
0.99
3.26
3.62
2000
1.01
3.34
3.51
2300
1.10
3.61
3.20
3000
1.36
4.46
2.44
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
75 Ohm Transline Cable, 1/2” – AT012J75/ AT012FX75/ AT012F75/ AT012R75
Description
Standard Cable
1/2", Black Polyethylene Jacket
Fire Retardant Cable
1/2", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Fire Retardant Cable
1/2”, Fire Retardant Jacket, IEC332-1,
MSHA
Riser Rated Cable
1/2”, Low-Smoke, Non-Halogenated,
Fire Retardant Jacket,IEC332-1,
IEC332-3C, UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AT012J75
AT012FX75
AT012F75
AT012R75
0.123 (3.12)
0.470 (11.94)
0.510 (12.95)
0.652 (16.56)
Copper-Clad Aluminum
Solid Aluminum
11
32
1.09 (3.58)
0.46 (1.51)
3.2
14.9 (48.9)
0.082 (0.269)
8
1.25 (19.0)
1.13 (24.3)
75
93%
2 (50.8)
6 (152)
0.10 (0.15)
7.5 (10.2)
465 (211)
62 (1.11)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.35
1.15
3.21
50
0.45
1.48
2.50
88
0.61
2.00
1.84
100
0.65
2.13
1.73
108
0.67
2.20
1.68
150
0.77
2.53
1.45
174
0.85
2.79
1.32
200
0.92
3.02
1.22
300
1.14
3.74
0.99
400
1.32
4.33
0.85
450
1.40
4.59
0.80
500
1.48
4.86
0.76
512
1.50
4.92
0.75
600
1.63
5.35
0.69
700
1.76
5.77
0.64
800
1.91
6.27
0.59
824
1.94
6.36
0.58
894
2.02
6.63
0.56
960
2.10
6.89
0.53
1000
2.15
7.05
0.52
1250
2.39
7.84
0.47
1500
2.60
8.53
0.43
1800
2.86
9.38
0.39
1900
2.94
9.65
0.38
2000
3.03
9.94
0.37
2300
3.26
10.70
0.34
3000
3.72
12.20
0.30
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
75 Ohm Transline Cable, 5/8” – AT058J75/ AT058FX75/ AT058R75
Description
Standard Cable
5/8", Black Polyethylene Jacket
Fire Retardant Cable
5/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Riser Rated Cable
5/8”, Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C,
UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AT058J75
AT058FX75
AT058R75
0.185 (4.7)
0.712 (18.08)
0.760 (19.30)
0.892 (22.65)
Copper-Clad Aluminum
Solid Aluminum Tube
8
38
0.46 (1.51)
0.23 (0.76)
4.75
14.9 (48.9)
0.083 (0.273)
8
1.25 (19.0)
1.13 (24.3)
75
93%
3 (76.2)
8 (203)
0.20 (0.29)
21 (28.5)
500 (227)
140 (2.50)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.25
0.82
5.76
50
0.32
1.05
4.50
88
0.43
1.41
3.35
100
0.46
1.51
3.13
108
0.48
1.57
3.00
150
0.56
1.84
2.68
174
0.60
1.97
2.40
200
0.65
2.13
2.22
300
0.79
2.59
1.82
400
0.91
2.99
1.58
450
0.97
3.18
1.48
500
1.03
3.38
1.40
512
1.04
3.41
1.38
600
1.11
3.64
1.30
700
1.20
3.94
1.20
800
1.30
4.27
1.11
824
1.32
4.33
1.09
894
1.37
4.49
1.05
960
1.44
4.72
1.00
1000
1.47
4.82
0.99
1250
1.62
5.31
0.89
1500
1.77
5.81
0.81
1800
1.95
6.40
0.74
1900
2.01
6.59
0.72
2000
2.07
6.79
0.70
2300
2.29
7.51
0.63
3000
2.62
8.59
0.55
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
TRANSLINE CABLE
®
Cable Specifications
75 Ohm Transline Cable, 7/8” – AT078J75/ AT078FX75/ AT078R75
Description
Standard Cable
7/8", Black Polyethylene Jacket
Fire Retardant Cable
7/8", Low-Smoke, Non-Halogenated,
Fire Retardant Jacket, IEC332-1
Riser Rated Cable
7/8”, Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C,
UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Max. Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res, Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Rad., in (mm) – Single
Min. Bend. Rad., in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AT078J75
AT078FX75
AT078R75
0.248 (6.30)
0.961 (24.41)
1.015 (25.78)
1.147 (29.13)
Copper-Clad Aluminum
Solid Aluminum Tube
6
68
0.26 (0.85)
0.15 (0.49)
6.4
14.9 (48.9)
0.083 (0.273)
8
1.25 (19.0)
1.13 (24.3)
75
93%
8 (203)
10 (254)
0.35 (0.47)
35 (47.5)
830 (377)
132 (2.36)
20
-40 to 170 (-40 to 77)
-94 to 170 (-70 to 77)
-40 to 170 (-40 to 77)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
30
0.18
0.59
9.46
50
0.23
0.75
7.41
88
0.30
0.98
5.68
100
0.32
1.05
5.32
108
0.34
1.12
5.01
150
0.40
1.31
4.51
174
0.43
1.41
3.96
200
0.46
1.51
3.70
300
0.60
1.97
2.84
400
0.70
2.30
2.43
450
0.74
2.43
2.30
500
0.78
2.56
2.18
512
0.79
2.59
2.16
600
0.87
2.85
1.96
700
0.94
3.08
1.81
800
1.02
3.35
1.67
824
1.04
3.41
1.64
894
1.08
3.54
1.58
960
1.13
3.71
1.51
1000
1.16
3.81
1.49
1250
1.30
4.26
1.31
1500
1.45
4.76
1.17
1800
1.62
5.31
1.06
1900
1.68
5.51
1.02
2000
1.74
5.71
0.98
2300
1.89
6.20
0.90
3000
2.16
7.09
0.79
Standard Conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC (68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no solar
loading
Product Certifications:
Transline cables and connectors are certified to exceed the strict
Verizon Wireless PIM [Passive Inter Modulation] and Motorola
25kW PIP [Peak Instantaneous Power] specifications
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
TRANSLINE CABLE
Hardware and Accessories
Accessories for AirCell® Transline Cable, 1/2"
Description
Product Code
A. Cable Hoisting and Attachment
Hoisting Grips
Lace-Up Hoisting Grips- Each
Pre-Laced Hoisting Grips- Each
HG-12
HG-12L
Coax Support Blocks
Mini Coax Support Blocks- Pkg. of 10
Large Coax Support Blocks- Pkg. of 10
Mounting Hardware Kits for Support Blocks
Galvanized. One Block- Pkg. of 10
Galvanized.Two Blocks- Pkg. of 10
Galvanized.Three Blocks- Pkg. of 10
Stainless Steel. Starter Kit- Pkg. of 10
Stainless Steel. Extender Kit- Pkg. of 10
CB-12
CB-12L
HK-SSCB
HK-DSCB
HK-TSCB
HK-SCBL
HK-ECBL
Description
Product Code
Metal Snips- Each
Banding Kit- Each
Trapeze Kits- Each
12" wide
24"wide
Tie Wraps- Pkg. of 50
MT-646
MT-647
B.Weatherproofing
3M Cold Shrink Weatherproofing Kits
Splices:
1/2" to 1/2"
Main Feed to Jumper:
7/8" to 1/2"
1 5/8" to 1/2"
Universal Weatherproofing Kit
Adaptors
MT-357-12
MT-357-24
TW-50
CS-U1212
CS-U1278
CS-U1258
WK-U
Assorted Tapes and Mastics- Each
Round Member Adaptors- Pkg. of 10
1"-2" (RM-A100)
3"-4" (RM-A300)
Universal Round Member Adaptors
Galvanized Version- Pkg. of 10
Stainless Steel Version- Pkg. of 10
Universal Round Member Hardware- Pkg. of 10
Universal Stainless Steel Angle Adaptors- Pkg. of 10
Stainless Steel Angle Adaptors- Pkg. of 10
Aluminum Angle Adaptors- Pkg. of 10
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized:
1"-2" (SA-UG100)
3"-4" (SA-UG300)
Universal Version, Stainless Steel:
1"-2" (SA-US100)
3"-4" (SA-US300)
Snap-In Version, Galvanized:
1"-2" (SA-SG100)
3"-4" (SA-SG300)
Snap-In Version, Stainless Steel:
1"-2" (SA-SS100)
3"-4" (SA-SS300)
2"-3" (RM-A200
4"-5" (RM-A400)
RM-USBG
RM-USBS
RM-BU
AA-U/AA-US
AA-SL
AA-AM
2"-3" (SA-UG200)
4"-5" (SA-UG400)
2"-3" (SA-US200)
4"-5" (SA-US400)
2"-3" (SA-SG200)
4"-5" (SA-SG400)
2"-3" (SA-SS200)
4"-5" (SA-SS400)
Electrical Tape. 3/4" x 44’ roll
Electrical Tape. 2" x 66’ roll
Electrical Tape. 2" x 20’ roll
Mastic Tape. 3 3/4" x 2’ roll
Vinyl-baked Mastic Tape. 2" x 3’ roll
MT-464
MT-465
MT-465-1
MT-469-2
MT-2228
C. Cable Entry
Tube Entry Kits- Each
12" Long
18" Long
24" Long
MT-101
MT-102
MT-103
Cushion Plugs and Inserts
Cushion Plugs- Pkg. of 5
Cushion Inserts- Each
Rectangular Port Cushion with 6 holes for 1/2"
Standard Port Cushion with 1 hole for 1/2"
Standard Port Cushion with 2 holes for 1/2"
Standard Port Cushion with 3 holes for 1/2"
Standard Port Cushion with 4 holes for 1/2"
CP-12
Entry Panels*
EP-XXX
BA-XXX
RC-12
SC-12-1
SC-12-2
SC-12-3
SC-12-4
D. Ground Kits
Hangers
Stainless Steel Butterfly Hangers-Pkg. of 10
Stainless Steel Clip Hangers- Pkg. of 10
Universal Snap-in Hangers- Pkg. of 10
BH-12
CH-12
SH-U12
Standard Ground Kits- Each
Mounting Hardware
Crimping Tool- Each
Banding Hardware
1/2" Stainless Steel Banding, 100’ RolL
1/2" Stainless Steel Buckle Clamps- Pkg. of 100
1/2" Galvanized Banding, 100’ RolL
1/2" Galvanized Buckle Clamps- Pkg. of 100
C-2 Banding Tool
12oz. Hammer
MT-640
MT-641
MT-642
MT-643
MT-644
MT-645
GK-S12AC
MT-639
Tools
1/2" All-in One Cable Prep ToolHigh Leverage Cable Cutter- Each
Tubing Cutter- Each
Knife-Box Cutter- Each
Cable Markers- Pkg. of 10
CT01250AIO
TC63050
TC1000
TC10099
CM-12X*-2
* Please Refer to Hardware and Accessories for full line of these products
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
24
TRANSLINE CABLE
Accessory Selection Information/Product Code
Accessories for AirCell® Transline Cable, 5/8"
Description
Product Code
A. Cable Hoisting and Attachment
Hoisting Grips
Lace-Up Hoisting Grips- Each
Pre-Laced Hoisting Grips- Each
HG-58
HG-58L
Description
Product Code
Metal Snips- Each
Banding Kit- Each
Trapeze Kits- Each
12" wide
24"wide
Tie Wraps- Pkg. of 50
MT-646
MT-647
MT-357-12
MT-357-24
TW-50
Adaptors
B.Weatherproofing
Round Member Adaptors- Pkg. of 10
1"-2" (RM-A100)
3"-4" (RM-A300)
Universal Round Member Adaptors
Galvanized Version- Pkg. of 10
Stainless Steel Version- Pkg. of 10
Universal Round Member Hardware- Pkg. of 10
Universal Stainless Steel Angle Adaptors- Pkg. of 10
Stainless Steel Angle Adaptors- Pkg. of 10
Aluminum Angle Adaptors- Pkg. of 10
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized:
1-2" (SA-UG100)
3-4" (SA-UG300)
Universal Version, Stainless Steel:
1-2" (SA-US100)
3-4" (SA-US300)
Snap-In Version, Galvanized:
1-2" (SA-SG100)
3-4" (SA-SG300)
Snap-In Version, Stainless Steel:
1-2" (SA-SS100)
3-4" (SA-SS300)
2"-3" (RM-A200)
4"-5" (RM-A400)
RM-USBG
RM-USBS
RM-BU
AA-U/AA-US
AA-SL
AA-AM
Universal Weatherproofing Kit
Assorted Tapes and Mastics-
MT-464
MT-465
MT-465-1
MT-469-2
MT-2228
C. Cable Entry
2-3" (SA-UG200)
4-5" (SA-UG400)
Tube Entry Kits- Each
2-3" (SA-US200)
4-5" (SA-US400)
12" Long
18" Long
24" Long
2-3" (SA-SG200)
4-5" (SA-SG400)
2-3" (SA-SS200)
4-5" (SA-SS400)
BH-58
SH-U58
MT-640
MT-641
MT-642
MT-643
MT-644
MT-645
MT-101
MT-102
MT-103
Cushion Plugs and Inserts
Cushion Inserts- Each
Standard Port Cushion with 1 hole for 5/8"
Entry Panels*
SC-58-1
EP-XXX
BA-XXX
D. Ground Kits
Standard Ground Kits- Each
Banding Hardware
1/2" Stainless Steel Banding, 100’ Roll
1/2" Stainless Steel Buckle Clamps - Pkg. of 10
1/2" Galvanized Banding, 100’ Roll
1/2" Galvanized Buckle Clamps - Pkg. of 10
C-2 Banding Tool
12oz. Hammer
Each
Electrical Tape. 3/4" x 44’ roll
Electrical Tape. 2" x 66’ roll
Electrical Tape. 2" x 20’ roll
Mastic Tape. 3 3/4" x 2’ roll
Vinyl-baked Mastic Tape. 2" x 3’ roll
Hangers
Stainless Steel Butterfly Hangers- Pkg. of 10
Universal Snap-in Hangers- Pkg. of 10
WK-U
GK-S58AC
Mounting Hardware
Crimping Tool- Each
MT-639
Tools
1/2" All-in One Cable Prep Tool
High Leverage Cable Cutter- Each
Tubing Cutter- Each
Knife-Box Cutter- Each
Cable Markers- Pkg. of 10
CT05850AIO
TC63050
TC1000
TC10099
CM-12X*-2
* Please Refer to Hardware and Accessories for full line of these products
25
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Accessory Selection Information/Product Code
Accessories for AirCell® Transline Cable, 7/8"
Description
Product Code
A. Cable Hoisting and Attachment
Hoisting Grips
Lace-Up Hoisting Grips- Each
Pre-Laced Hoisting Grips- Each
HG-78
HG-78L
Coax Support Blocks
Mini Coax Support Blocks- Pkg. of 10
Large Coax Support Blocks- Pkg. of 10
Mounting Hardware Kits for Support BlocksGalvanized. One Block- Pkg. of 10
Galvanized.Two Blocks- Pkg. of 10
Galvanized.Three Blocks- Pkg. of 10
Stainless Steel. Starter Kit- Pkg. of 10
Stainless Steel. Extender Kit- Pkg. of 10
CB-78
CB-78L
HK-SSCB
HK-DSCB
HK-TSCB
HK-SCBL
HK-ECBL
Description
Metal Snips- Each
Banding Kit- Each
Trapeze Kits- Each
12" wide
24"wide
Tie Wraps- Pkg. of 50
Round Member Adaptors- Pkg. of 10
1"-2" (RM-A100)
3"-4" (RM-A300)
Universal Round Member Adaptors
Galvanized Version- Pkg. of 10
Stainless Steel Version- Pkg. of 10
Universal Round Member Hardware- Pkg. of 10
Universal Stainless Steel Angle Adaptors- Pkg. of 10
Stainless Steel Angle Adaptors- Pkg. of 10
Aluminum Angle Adaptors- Pkg. of 10
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized:
1-2" (SA-UG100)
3-4" (SA-UG300)
Universal Version, Stainless Steel:
1-2" (SA-US100)
Snap-In Version, Galvanized:
1-2" (SA-SG100)
3-4" (SA-SG300
Snap-In Version, Stainless Steel:
1-2" (SA-SS100)
3-4" (SA-SS300)
2"-3" (RM-A200)
4"-5" (RM-A400)
RM-USBG
RM-USBS
RM-BU
AA-U/AA-US
AA-SL
AA-AM
2-3" (SA-UG200)
4-5" (SA-UG400)
4-5" (SA-US400)
2-3" (SA-SG200)
4-5" (SA-SG400)
2-3" (SA-SS200)
4-5" (SA-SS400)
MT-646
MT-647
MT-357-12
MT-357-24
TW-50
B.Weatherproofing
3M™ Cold Shrink™ Weatherproofing Kits
Splices:
7/8" to 7/8"
Main Feed to Jumper:
7/8" to 1/2"
CS-U1278
CS-U1278
Universal Weatherproofing Kit
Assorted Tapes and Mastics-
Adaptors
Product Code
WK-U
Each
Electrical Tape. 3/4" x 44’ roll
Electrical Tape. 2" x 66’ roll
Electrical Tape. 2" x 20’ roll
Mastic Tape. 3 3/4" x 2’ roll
Vinyl-baked Mastic Tape. 2" x 3’ roll
MT-464
MT-465
MT-465-1
MT-469-2
MT-2228
C. Cable Entry
Tube Entry Kits- Each
12" Long
18" Long
24" Long
MT-101
MT-102
MT-103
Cushion Plugs and Inserts
Cushion Plugs- Pkg. of 5
Cushion Inserts- Each
Rectangular Port Cushion with 4 holes for 7/8"
Standard Port Cushion with 1 hole for 7/8"
Standard Port Cushion with 2 holes for 7/8"
Standard Port Cushion with 3 holes for 7/8"
Standard Port Cushion with 4 holes for 7/8"
CP-78
Entry Panels*
EP-XXX
BA-XXX
RC-78
SC-78-1
SC-78-2
SC-78-3
SC-78-4
D. Ground Kits
Hangers
Stainless Steel Butterfly Hangers- Pkg. of 10
Stainless Steel Clip Hangers- Pkg. of 10
Universal Snap-in Hangers- Pkg. of 10
BH-78
CH-78
SH-U78
Standard Ground Kits- Each
Mounting Hardware
Crimping Tool- Each
Banding Hardware
1/2" Stainless Steel Banding, 100’ Roll
1/2" Stainless Steel Buckle Clamps- Pkg. of 10
1/2" Galvanized Banding, 100’ Roll
1/2" Galvanized Buckle Clamps- Pkg. of 10
C-2 Banding Tool
12oz. Hammer
MT-640
MT-641
MT-642
MT-643
MT-644
MT-645
GK-S78AC
MT-639
Tools
1/2" All-in One Cable Prep Tool
High Leverage Cable Cutter- Each
Tubing Cutter- Each
Knife-Box Cutter- Each
Cable Markers- Pkg. of 10
CT07850AIO
TC63050
TC1000
TC10099
CM-78X*-2
* Please Refer to Hardware and Accessories for full line of these products
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
26
® TRANSLINE CABLE
AirCell
Accessory Selection Information/Product Code
Accessories for AirCell® Transline Cable, 1-1/4"
Description
Product Code
A. Cable Hoisting and Attachment
Hoisting Grips
Lace-Up Hoisting Grips- Each
Pre-Laced Hoisting Grips- Each
HG-114
HG-114L
Coax Support Blocks
Mini Coax Support Blocks- Pkg. of 10
Large Coax Support Blocks- Pkg. of 10
Mounting Hardware Kits for one 1 1/4" Support BlocksGalvanized. One Block- Pkg. of 10
Galvanized.Two Blocks- Pkg. of 10
Galvanized.Three Blocks- Pkg. of 10
Stainless Steel. Starter Kit- Pkg. of 10
Stainless Steel. Extender Kit- Pkg. of 10
CB-114
CB-114L
Description
C-2 Banding Tool
12oz. Hammer
Metal Snips- Each
Banding Kit- Each
Trapeze Kits- Each
12" wide
24"wide
Tie Wraps- Pkg. of 50
Product Code
MT-644
MT-645
MT-646
MT-647
MT-357-12
MT-357-24
TW-50
B.Weatherproofing
HK-SSCB158
HK-DSCB158
HK-TSCB158
HK-SCBL158
HK-ECBL158
3M Cold Shrink Weatherproofing Kits
Splices:
1 1/4" to 1 5/8"
Main Feed to Jumper:
1 1/4" to 1/2"
CS-U12158
CS-U12158
Adaptors
Universal Weatherproofing Kit
Round Member Adaptors- Pkg. of 10
1"-2" (RM-A100)
3"-4" (RM-A300)
Universal Round Member Adaptors
Galvanized Version- Pkg. of 10
Stainless Steel Version- Pkg. of 10
Universal Round Member Hardware- Pkg. of 10
Universal Stainless Steel Angle Adaptors- Pkg. of 10
Stainless Steel Angle Adaptors- Pkg. of 10
Aluminum Angle Adaptors- Pkg. of 10
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized:
1-2" (SA-UG100)
3-4" (SA-UG300)
Universal Version, Stainless Steel:
1-2" (SA-US100)
3-4" (SA-US300)
Snap-In Version, Galvanized:
1-2" (SA-SG100)
3-4" (SA-SG300)
Snap-In Version, Stainless Steel:
1-2" (SA-SS100)
3-4" (SA-SS300)
2"-3" (RM-A200)
4"-5" (RM-A400)
RM-USBG
RM-USBS
RM-BU
AA-U/AA-US
AA-SL
AA-AM
2-3" (SA-UG200)
4-5" (SA-UG400)
2-3" (SA-US200)
4-5" (SA-US400)
2-3" (SA-SG200)
4-5" (SA-SG400)
2-3" (SA-SS200)
4-5" (SA-SS400)
WK-U
Assorted Tapes and Mastics- Each
Electrical Tape. 3/4" x 44’ roll
Electrical Tape. 2" x 66’ roll
Electrical Tape. 2" x 20’ roll
Mastic Tape. 3 3/4" x 2’ roll
Vinyl-baked Mastic Tape. 2" x 3’ roll
MT-464
MT-465
MT-465-1
MT-469-2
MT-2228
C. Cable Entry
Tube Entry Kits- Each
12" Long
18" Long
24" Long
MT-101
MT-102
MT-103
Cushion Plugs and Inserts
Cushion Plugs
Cushion Inserts
Rectangular
Standard Port Cushion with 1 hole for 1-1/4"
Entry Panels*
SC-114-1
EP-XXX
BA-XXX
D. Ground Kits
Hangers
Stainless Steel Butterfly Hangers- Pkg. of 10
Stainless Steel Clip Hangers- Pkg. of 10
Universal Snap-in Hangers- Pkg. of 10
BH-114
CH-114
SH-U114
Banding Hardware
1/2" Stainless Steel Banding, 100’ Roll
1/2" Stainless Steel Buckle Clamps- Pkg. of 100
1/2" Galvanized Banding, 100’ Roll
1/2" Galvanized Buckle Clamps- Pkg. of 100
MT-640
MT-641
MT-642
MT-643
Standard Ground Kits- Each
GK-S114/158AC
MOUNTING HARDWARE
Crimping Tool- Each
MT-639
TOOLS
1/2" All-in One Cable Prep Tool
High Leverage Cable Cutter- Each
Tubing Cutter- Each
Knife-Box Cutter- Each
Cable Markers- Pkg. of 10
CT15850AIO
TC63050
TC1000
TC10099
CM-158X*-2
* Please Refer to Hardware and Accessories for full line of these products
27
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
TRANSLINE CABLE
Accessory Selection Information/Product Code
Accessories for AirCell® Transline Cable, 1-5/8"
Description
Product Code
A. Cable Hoisting and Attachment
Hoisting Grips
Lace-Up Hoisting Grips- Each
Pre-Laced Hoisting Grips- Each
HG-158
HG-158L
Coax Support Blocks
Mini Coax Support Blocks- Pkg. of 10
Large Coax Support Blocks- Pkg. of 10
Mounting Hardware Kits for one 1 5/8" Support BlocksGalvanized. One Block- Pkg. of 10
Galvanized.Two Blocks- Pkg. of 10
Galvanized.Three Blocks- Pkg. of 10
Stainless Steel. Starter Kit- Pkg. of 10
Stainless Steel. Extender Kit- Pkg. of 10
CB-158
CB-158L
Description
Product Code
C-2 Banding Tool
12oz. Hammer
Metal Snips- Each
Banding Kit- Each
Trapeze Kits- Each
12" wide
24"wide
Tie Wraps- Pkg. of 50
MT-644
MT-645
MT-646
MT-647
MT-357-12
MT-357-24
TW-50
B.Weatherproofing
HK-SSCB158
HK-DSCB158
HK-TSCB158
HK-SCBL158
HK-ECBL158
3M Cold Shrink Weatherproofing Kits
Splices:
1 5/8" to 1 5/8"
Main Feed to Jumper:
1 5/8" to 1/2"
CS-U12158
CS-U1258
Adaptors
Universal Weatherproofing Kit
Round Member Adaptors- Pkg. of 10
1"-2" (RM-A100)
3"-4" (RM-A300)
Universal Round Member Adaptors
Galvanized Version- Pkg. of 10
Stainless Steel Version- Pkg. of 10
Universal Round Member Hardware- Pkg. of 10
Universal Stainless Steel Angle Adaptors- Pkg. of 10
Stainless Steel Angle Adaptors- Pkg. of 10
Aluminum Angle Adaptors- Pkg. of 10
Universal Stand-Off Adaptors- Pkg. of 10
Universal Version, Galvanized:
1-2" (SA-UG100)
3-4" (SA-UG300)
Universal Version, Stainless Steel:
1-2" (SA-US100)
3-4" (SA-US300)
Snap-In Version, Galvanized:
1-2" (SA-SG100)
3-4" (SA-SG300)
Snap-In Version, Stainless Steel:
1-2" (SA-SS100)
3-4" (SA-SS300)
2"-3" (RM-A200)
4"-5" (RM-A400)
RM-USBG
RM-USBS
RM-BU
AA-U/AA-US
AA-SL
AA-AM
2-3" (SA-UG200)
4-5" (SA-UG400)
2-3" (SA-US200)
4-5" (SA-US400)
2-3" (SA-SG200)
4-5" (SA-SG400)
2-3" (SA-SS200)
4-5" (SA-SS400)
WK-U
Assorted Tapes and Mastics- Each
Electrical Tape. 3/4" x 44’ roll
Electrical Tape. 2" x 66’ roll
Electrical Tape. 2" x 20’ roll
Mastic Tape. 3 3/4" x 2’ roll
Vinyl-baked Mastic Tape. 2" x 3’ roll
MT-464
MT-465
MT-465-1
MT-469-2
MT-2228
C. Cable Entry
Tube Entry Kits- Each
12" Long
18" Long
24" Long
MT-101
MT-102
MT-103
Cushion Plugs and Inserts
Cushion Plugs- Pkg. of 5
Cushion Inserts- Each
Rectangular Port Cushion with 2 holes for 1-5/8"
Standard Port Cushion with 1 hole for 1-5/8"
CP-158
Entry Panels*
EP-XXX
BA-XXX
RC-158
SC-158-1
D. Ground Kits
Hangers
Stainless Steel Butterfly Hangers- Pkg. of 10
Stainless Steel Clip Hangers- Pkg. of 10
Universal Snap-in Hangers- Pkg. of 10
BH-158
CH-158
SH-U158
Banding Hardware
1/2" Stainless Steel Banding, 100’ Roll
1/2" Stainless Steel Buckle Clamps- Pkg. of 100
1/2" Galvanized Banding, 100’ Roll
1/2" Galvanized Buckle Clamps- Pkg. of 100
MT-640
MT-641
MT-642
MT-643
Standard Ground Kits- Each
GK-S158AC
MOUNTING HARDWARE
Crimping Tool- Each
MT-639
TOOLS
1/2" All-in One Cable Prep Tool
High Leverage Cable Cutter- Each
Tubing Cutter- Each
Knife-Box Cutter- Each
Cable Markers- Pkg. of 10
CT15850AIO
TC63050
TC1000
TC10099
CM-158X*-2
* Please Refer to Hardware and Accessories for full line of these products
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
28
PLENUM CABLES
Table Of Contents
V. AirCell® Plenum Cables
45
Pages
A. Overview and Product Description
46-48
B. Cable Selection Guide
49
C. Specification Sheets
50-54
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
PLENUM CABLES
Overview
Trilogy’s AirCell® Plenum 50 and 75 Ohm coaxial cables provide the most effective solution to your networking
applications. AirCell® Plenum cables are certified for use in plenum air spaces or other environments within
buildings where stringent fire protection codes are in effect. Specific applications for these cables include LAN’s
and WAN’s, wireless PBX’s, cellular, PCS, and paging.
AirCell® Plenum cables utilize a superior air-dielectric construction. Because each has a unique dielectric disc and
corrugated outer conductor design, AirCell® Plenum cables offer a lightweight combination of excellent flexibility
and high crush strength, and unbeatable electrical performance. These attributes make AirCell® Plenum cables
the product of choice for superior performance in hospitals, office buildings, malls, underground walkways, or any
indoor area that needs to meet stringent fire codes.
Through innovative design and research,Trilogy has pioneered AirCell® Plenum coaxial cables to eliminate the use
of Teflon, while retaining superior electrical performance. AirCell® Plenum cables exceed all of the requirements of
the UL 910 Steiner Tunnel Test for smoke generation and flame propagation.
Trilogy’s AirCell® Plenum cables are available in both radiating and non-radiating versions in 1/2" size with
impedances of 50 Ohms or 75 Ohms.
Advantages of AirCell® Plenum Cables
Low attenuation
The patented air-dielectric design and 93% velocity of propagation in AirCell® Plenum cables result in low
attenuation, which provides a highly efficient signal transfer in your RF system and maximum system performance.
Increased Flexibility
AirCell® Plenum cables are designed for the restricted areas of overhead plenums where multiple bends are
required. Because AirCell® Plenum cables use a corrugated aluminum outer conductor to ensure excellent
flexibility, installation of these cables is much easier. The AirCell® Plenum cable features a 5 inch bend radius
and can endure multiple bends during installation without damaging the structure of the cable.
Superior Durability
AirCell® Plenum cables are longitudinally strong, crush resistant, and flexible. This rugged construction ensures
that installations are trouble free and that in-service life and system reliability is maximized.
Ease of Connectorization
AirCell® Plenum cable connectorization is extremely simple, fast, and requires no soldering. The two-piece
design of connectors for AirCell® Plenum cable can be easily attached in the field with standard hand tools.
AirCell® connectors provide high resistance to connector pull-out and excellent electrical contact.Together,
Trilogy’s cables and connectors are an unbeatable match that optimize entire system performance.
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
46
PLENUM CABLES
Overview
Level of Fire Retardancy
AirCell® Plenum cables comply with Underwriters’ Laboratories, Inc.’s (UL) and the National Electric Code’s (NEC)
most stringent fire retardancy requirements.
AirCell® Fire Retardancy Ratings
47
Applications
UL VW1/CMX
Vertical Wire Flame Test
For use in enclosed raceways, conduit and dwellings.
Must be listed as flame retardant.
UL 1581/CATV
Vertical Tray Flame Test
General purpose except in risers and plenums.
Must be listed as flame retardant.
UL 1666/CMR
Riser Cable Test
For use in vertical runs in a shaft or from floor to
floor. Must be listed as flame retardant.
UL 910/CMP
Steiner Tunnel Test
This test is the highest level of fire retardancy in the
National Electric Code. Therefore, cables meeting
this requirement can also be used in the above
lower level categories.
CSA C.22.2/FT6
Canadian Plenum Test
Canadian version of UL 910/CMP.
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
PLENUM CABLES
Product Description
Premium Performance Cable
Center Conductor
The center conductor of the cable consists of a copper-clad electrical
grade aluminum wire, nominal 10% copper by volume which conforms
to ASTM B-566, class 10A. This lightweight conductor provides both
high quality and strength.
Conductor Adhesive
The center conductor is coated with a proprietary adhesive that
ensures the discs are securely bonded to the center conductor.
Dielectric Discs
The dielectric discs are injection molded from virgin polyethylene
(ASTM D-1248). These discs are regularly spaced to provide structural
integrity while minimizing attenuation.
Aluminum Outer Conductor
The outer conductor is a continuously formed corrugated and welded
electrical grade aluminum tube. In-process monitoring assures weld
integrity, maintains proper aluminum thickness, and corrects physical
dimensions.
Jacket
The Jacket is composed of a highly flame retardant, low smoke
material meeting the fire retardant provisions for plenum applications.
Consequently, this cable is certified according to the test methods
of UL 910 and the listing requirements of NEC 820-51 and NEC
820-53 (a) for CATVP cables. In addition, it exceeds FT6 provisions
of the Canadian Electric Code.
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
48
AirCell
PLENUM CABLE
®
Cable Specifications Summary
50 and 75 Ohm Plenum and Plenum Radiating, 1/2"
50 Ohm
Aluminum
Product Code
Plenum
50 Ohm
Copper
Product Code
75 Ohm
Aluminum
Product Code
Jacketed CMP (UL-910, UL-444),
Canadian CSA 22.2/FT6
AP6012J50
APC012J50
AP012J75
AQ012J50
AQC012J50
Unjacketed UL-444
AP012U50
N/A
N/A
N/A
N/A
0.540 (13.72)
0.615 (15.62)
0.540 (13.72)
0.615 (15.62)
0.540 (13.72)
0.615 (15.62)
0.540 (13.72)
0.615 (15.62)
0.540 (13.72)
0.615 (15.62)
0.129 (0.192)
0.082 (0.122)
5 (127)
50
94%
10
35
0.190 (0.280)
N/A
5 (127)
50
94%
10
40
0.104 (0.155)
N/A
5 (127)
75
95%
12
35
0.122 (0.181)
N/A
5 (127)
50
93%
10
35
0.17 (0.25)
N/A
5 (127)
50
96%
10
40
100 MHz
450 MHz
900 MHz
1000 MHz
1700 MHz
2000 MHz
2300 MHz
2400 MHz
0.70 (2.30)
1.50 (4.92)
2.14 (7.02)
2.30 (7.54)
3.05 (10.00)
3.33 (10.92)
3.59 (11.78)
3.67 (12.04)
0.65 (2.13)
1.43 (4.69)
1.98 (6.49)
2.10 (6.89)
2.79 (9.15)
3.05 (10.00)
3.33 (10.92)
3.42 (11.22)
0.71 (2.32)
1.48 (4.87)
2.14 (7.01)
2.26 (7.41)
3.01(9.88)
3.29 (10.80)
3.52 (11.60)
3.60 (11.80)
0.97 (3.19)
2.60 (8.52)
4.09 (13.40)
4.27 (14.00)
5.66 (18.60)
6.43 (21.10)
7.12 (23.38)
7.34 (24.10)
0.92 (3.01)
1.96 (6.42)
2.78 (9.13)
2.94 (9.63)
3.85 (12.63)
4.18 (13.72)
4.49 (14.74)
4.59 (15.07)
3000 MHz
4.14 (13.58)
3.83 (12.56)
4.03 (13.20)
8.82 (29.00)
5.15 (16.90)
Outer Conductor
Jacketing
Plenum Radiating
50 Ohm
50 Ohm
Aluminum
Copper
Product Code Product Code
Characteristics
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Cable Weight, lb/ft (kg/m)
Jacketed
Unjacketed
Min. Bending Radius, in (mm)
Impedance, Ohms
Velocity of Propagation
Maximum Frequency, GHz
Peak Power Rating, kW
Attenuation, dB/100 ft (dB/100 m)
Average Power/Coupling Loss
100 MHz
450 MHz
900 MHz
1000 MHz
1700 MHz
2000 MHz
2300 MHz
2400 MHz
Average Power Rating, kW
3.98
1.85
1.29
1.21
0.98
0.84
0.78
0.77
4.82
2.21
1.55
1.46
1.10
1.01
0.94
0.91
Coupling Loss, dB*
1.97
0.94
0.66
0.62
0.46
0.43
0.40
0.39
49
61
63
64
65
69
70
70
55
63
65
65
66
67
68
68
* 5 0 % C o u p l i n g L o s s a t s t a n d a r d s 6 f t ( 2 m ) , ± 5 dB
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
1/15
AirCell
PLENUM CABLE
®
Cable Specifications
50 Ohm Plenum, 1/2” (6 GHz) – AP6012J50
Description
Standard Cable
1/2", Corrugated, (6 GHz), Jacketed
CMP (UL-910, UL-444), Canadian CSA
22.2/FT6
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Jacket Color
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res., Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends, minimum
Number of Bends, typical
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AP6012J50
0.188 (4.78)
0.470 (11.94)
0.540 (13.72)
0.615 (15.62)
Copper-Clad Aluminum
Corrugated Aluminum
Off-white
10
35
0.46 (1.51)
0.51 (1.67)
4
22 (72.12)
0.057 (0.187)
8
1.25 (19.0)
1.13 (24.3)
50
94%
2 (50.8)
5 (127)
0.129 (0.192)
1 (1.4)
250 (114)
78 (1.39)
15
25
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
100
0.70
2.30
3.98
450
1.50
4.92
1.85
500
1.59
5.22
1.75
600
1.75
5.74
1.58
700
1.87
6.13
1.47
800
1.96
6.43
1.37
900
2.14
7.02
1.29
960
2.23
7.31
1.24
1000
2.30
7.54
1.21
1500
2.85
9.35
0.98
1700
3.05
10.00
0.98
1800
3.14
10.30
0.93
1950
3.24
10.63
0.85
2000
3.33
10.92
0.84
2100
3.42
11.22
0.82
2200
3.50
11.48
0.80
2300
3.59
11.78
0.78
2400
3.67
12.04
0.77
2500
3.75
12.30
0.75
2700
3.90
12.82
0.72
3000
4.14
13.58
0.68
3300
4.33
14.20
0.61
3400
4.45
14.60
0.60
4000
4.91
16.10
0.55
4900
5.61
18.40
0.50
5000
5.69
18.66
0.49
5200
5.92
19.42
0.48
5300
6.03
19.78
0.47
5600
6.37
20.89
0.46
5825
6.83
22.40
0.45
Standard conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC
(68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no
solar loading
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
PLENUM CABLE
®
Cable Specifications
50 Ohm Plenum, 1/2” (6 GHz)
Copper Outer Conductor – APC012J50
Description
Standard Cable
1/2", Corrugated, Jacketed CMP
(UL-910, UL-444), Canadian CSA
22.2/FT6
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Jacket Color
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res., Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends, minimum
Number of Bends, typical
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
Attenuation and Average Power
Frequency
MHz
APC012J50
0.188 (4.78)
0.470 (11.94)
0.540 (13.72)
0.615 (15.62)
Copper-Clad Aluminum
Corrugated Copper
Off-white
10
40
0.46 (1.51)
0.39 (1.28)
4
22 (72.12)
0.057 (0.187)
8
1.25 (19.0)
1.13 (24.3)
50
94%
2 (50.8)
5 (127)
0.190 (0.280)
3 (4.1)
275 (125)
110 (2.00)
15
20
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
Attenuation
dB/100 ft dB/100m
100
450
500
600
700
800
900
960
1000
1500
1700
1800
1950
2000
2100
2200
2300
2400
2500
2700
3000
3300
3400
4000
4900
5000
5200
5300
5600
5825
0.65
1.43
1.52
1.64
1.75
1.87
1.98
2.04
2.10
2.62
2.79
2.88
3.01
3.05
3.14
3.23
3.33
3.42
3.48
3.65
3.83
4.02
4.08
4.45
5.00
5.06
5.34
5.48
5.90
6.32
2.13
4.69
4.99
5.38
5.74
6.13
6.49
6.69
6.89
8.59
9.15
9.45
9.87
10.00
10.30
10.59
10.92
11.22
11.41
11.97
12.56
13.19
13.38
14.60
16.40
16.60
17.52
17.97
19.35
20.73
Avg. Pwr.
kW
4.82
2.21
2.10
1.91
1.76
1.68
1.55
1.49
1.46
1.18
1.10
1.07
1.02
1.01
0.99
0.96
0.94
0.91
0.90
0.86
0.81
0.76
0.66
0.69
0.60
0.60
0.58
0.57
0.53
0.49
Standard conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC
(68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no
solar loading
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
3/15
AirCell
PLENUM RADIATING CABLE
®
Cable Specifications
50 Ohm Plenum Radiating, 1/2” – AQ012J50
Description
Standard Cable
1/2", Corrugated, Jacketed CMP (UL910, UL-444), Canadian CSA 22.2/FT6
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Jacket Color
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res., Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends, minimum
Number of Bends, typical
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AQ012J50
0.188 (4.78)
0.470 (11.94)
0.540 (13.72)
0.615 (15.62)
Copper-Clad Aluminum
Corrugated Aluminum
Off-white
10
35
0.46 (1.51)
0.51 (1.67)
4
22 (72.12)
0.057 (0.187)
8
1.38 (16.0)
1.30 (17.7)
50
94%
2 (50.8)
5 (127)
0.122 (0.181)
1 (1.4)
250 (114)
50 (0.89)
10
15
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
Attenuation and Average Power
Frequency
**Attenuation
*Coupling
MHz
dB/100 ft dB/100m
Loss dB
30
0.55
1.81
49
50
0.64
2.11
49
88
0.90
2.96
49
100
0.97
3.19
49
108
1.02
3.35
49
150
1.27
4.14
49
174
1.40
4.60
50
200
1.54
5.06
50
300
2.04
6.70
51
400
2.40
7.88
58
450
2.60
8.52
61
500
2.78
9.13
61
512
2.82
9.26
61
600
3.13
10.30
62
700
3.46
11.36
62
800
3.77
12.38
63
824
3.84
12.61
63
894
4.07
13.37
63
900
4.09
13.40
63
960
4.20
13.79
64
1000
4.27
14.00
64
1250
4.83
15.86
64
1500
5.34
15.50
65
1700
5.66
18.60
65
1800
5.82
19.10
66
1950
6.29
20.60
69
2000
6.43
21.10
69
2300
7.12
23.38
70
2400
7.34
24.10
70
3000
8.82
29.00
70
Standard conditions:
Test per IEC61196-4
*95% Coupling Loss at 6 ft (2 m), ± 5 dB
The coupling loss values given are average values of all three
antenna orientations (radial, parallel, and orthogonal) of
dipole antenna.
**Attenuation ± 10% at 68oF
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
5/15
AirCell
PLENUM RADIATING CABLE
®
Cable Specifications
50 Ohm Plenum Radiating, 1/2”
Copper Outer Conductor – AQC012J50
Description
Standard Cable
1/2", Corrugated, Jacketed CMP (UL910, UL-444), Canadian CSA 22.2/FT6
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Jacket Color
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res., Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends, minimum
Number of Bends, typical
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
Attenuation and Average Power
**Attenuation
*Coupling
dB/100 ft dB/100m
Loss dB
30
0.50
1.64
55
50
0.65
2.82
55
88
0.86
2.82
55
100
0.92
3.01
55
108
0.95
3.13
56
150
1.12
3.69
56
174
1.21
3.97
63
200
1.30
4.26
63
300
1.59
5.23
63
400
1.84
6.05
63
450
1.96
6.42
63
500
2.06
6.77
64
512
2.09
6.85
64
600
2.26
7.43
64
700
2.45
8.03
64
800
2.62
8.60
64
824
2.66
8.73
64
894
2.77
9.10
64
900
2.78
9.13
65
960
2.87
9.43
65
1000
2.94
9.63
65
1250
3.29
10.79
65
1500
3.61
11.84
66
1700
3.85
12.63
66
1800
3.96
13.00
66
1950
4.13
13.55
66
2000
4.18
13.72
67
2300
4.49
14.74
68
2400
4.59
15.07
68
3000
5.15
16.90
69
Frequency
MHz
AQC012J50
0.188 (4.78)
0.470 (11.94)
0.540 (13.72)
0.615 (15.62)
Copper-Clad Aluminum
Corrugated Copper
Off-white
10
40
0.46 (1.51)
0.42 (1.38)
4
22 (72.12)
0.057 (0.187)
8
1.38 (16.0)
1.30 (17.7)
50
94%
2 (50.8)
5 (127)
0.17 (0.25)
3.0 (4.1)
250 (114)
110 (2.0)
15
20
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
Standard conditions:
Test per IEC61196-4
*95% Coupling Loss at 6 ft (2 m), ± 5 dB
The coupling loss values given are average values of all three
antenna orientations (radial, parallel, and orthogonal) of
dipole antenna.
**Attenuation ± 10% at 68oF
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
PLENUM CABLE
®
Cable Specifications
75 Ohm Plenum, 1/2” – AP012J75
Description
Standard Cable
1/2", Corrugated Cable, Jacketed CMP
(UL-910, UL-444), Canadian CSA
22.2/FT6
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Jacket Color
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res., Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends, minimum
Number of Bends, typical
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
AP012J75
0.123 (3.12)
0.435 (11.05)
0.540 (13.72)
0.615 (15.62)
Copper-Clad Aluminum
Corrugated Aluminum
Off-white
12
35
1.09 (3.58)
0.51 (1.67)
4
14.84 (48.68)
0.080 (0.264)
8
1.25 (19.0)
1.13 (24.3)
75
95%
2 (50.8)
5 (127)
0.104 (0.155)
1 (1.4)
145 (66)
78 (1.39)
15
20
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
Attenuation and Average Power
Frequency
Attenuation
Avg. Pwr.
MHz
dB/100 ft dB/100m
kW
5
0.15
0.49
9.33
10
0.21
0.70
6.60
20
0.30
0.98
4.66
30
0.37
1.21
3.78
50
0.48
1.57
2.93
88
0.66
2.18
2.10
100
0.71
2.32
1.97
108
0.74
2.42
1.90
150
0.87
2.85
1.61
174
0.93
3.07
1.50
200
1.00
3.29
1.40
300
1.20
3.94
1.17
400
1.40
4.59
1.00
450
1.48
4.87
0.94
500
1.57
5.15
0.89
512
1.59
5.21
0.88
600
1.73
5.68
0.81
700
1.87
6.13
0.75
800
2.02
6.62
0.69
824
2.05
6.73
0.68
894
2.14
7.01
0.66
960
2.21
7.25
0.63
1000
2.26
7.41
0.62
1250
2.57
8.43
0.54
1500
2.81
9.22
0.50
1700
3.01
9.88
0.46
1950
3.25
10.66
0.43
2000
3.29
10.79
0.43
2300
3.52
11.54
0.40
2400
3.60
11.81
0.39
3000
4.03
13.22
0.35
Standard conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC
(68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no
solar loading
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
IN-CONDUIT CABLE
®
Cable Specifications
50 Ohm In-Conduit, 1/2” – AC012J50/ AC012R50
Description
Standard Cable
1/2", In-Conduit, 50 Ohm, Corrugated,
Black Polyethylene Jacket
Riser Rated Cable
1/2", In-Conduit, 50 Ohm, Corrugated,
Low-Smoke, Non-Halogenated, Fire
Retardant Jacket, IEC332-1, IEC332-3C,
UL-1666, CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res., Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends, minimum
Number of Bends, typical
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
Attenuation and Average Power
Frequency
MHz
AC012J50
AC012R50
0.188 (4.78)
0.470 (11.94)
0.540 (13.72)
0.615 (15.62)
Copper-Clad Aluminum
Corrugated Aluminum
10
35
0.46 (1.51)
0.51 (1.67)
4
22 (72.12)
0.057 (0.187)
8
1.25 (19.0)
1.13 (24.3)
50
94%
2 (50.8)
5 (127)
0.129 (0.192)
1 (1.4)
250 (114)
78 (1.39)
15
25
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
Attenuation
dB/100 ft dB/100m
100
450
500
600
700
800
900
960
1000
1500
1700
1800
1950
2000
2100
2200
2300
2400
2500
2700
3000
3300
3400
4000
4900
5000
5200
5300
5600
5825
0.70
1.50
1.59
1.75
1.87
1.96
2.14
2.23
2.30
2.85
3.05
3.14
3.24
3.33
3.42
3.50
3.59
3.67
3.75
3.90
4.14
4.33
4.45
4.91
5.61
5.69
5.92
6.03
6.37
6.83
2.30
4.92
5.22
5.74
6.13
6.43
7.02
7.31
7.54
9.35
10.00
10.30
10.63
10.92
11.22
11.48
11.78
12.04
12.30
12.82
13.58
14.20
14.60
16.10
18.40
18.66
19.42
19.78
20.89
22.40
Avg. Pwr.
kW
3.98
1.85
1.75
1.58
1.47
1.37
1.29
1.24
1.21
0.98
0.98
0.93
0.85
0.84
0.82
0.80
0.78
0.77
0.75
0.72
0.68
0.61
0.60
0.55
0.50
0.49
0.48
0.47
0.46
0.45
Standard conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC
(68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no
solar loading
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/15
AirCell
IN-CONDUIT CABLE
®
Cable Specifications
50 Ohm In-Conduit, 1/2”
Copper Outer Conductor – ACC012J50/ ACC012R50
Description
Standard Cable
1/2", In-Conduit, 50 Ohm, Corrugated,
Copper Outer Conductor, Black
Polyethylene Jacket
Fire Retardant Cable
1/2", In-Conduit, 50 Ohm, Corrugated,
Copper Outer Conductor, Fire Retardant
Jacket, Meet / Exceed CMR
Physical Dimensions
Center Dia., in (mm)
Dia. Over Dielectric, in (mm)
Dia. Over Outer Conductor, in (mm)
Dia. Over Jacket, in (mm)
Center Conductor
Outer Conductor
Electrical Characteristics
Maximum Frequency, GHz
Peak Power Rating, KW
DC Res., Ohms/1000 ft (1000m)
Center
Outer
DC Breakdown, kV
Capacitance, pF/ft (m)
Inductance, mH/ft (m)
Jacket Spark, kV RMS
VSWR min, (dB)
VSWR in-band, (dB)
Impedance, Ohms
Velocity of Propagation
Mechanical Characteristics
Min. Bend. Radius, in (mm) – Single
Min. Bend. Radius, in (mm) – Multiple
Cable Weight, lb/ft (kg/m)
.
Bending Moment, ft.lb (N m)
Tensile Strength, lb (kg)
Flat Plate Crush, lb/in (kg/mm)
Number of Bends, minimum
Number of Bends, typical
o
o
Recommended Install Temp., F ( C)
o
o
Recommended Storage Temp., F ( C)
o
o
Recommended Operating Temp., F ( C)
Product Number
Attenuation and Average Power
Frequency
MHz
ACC012J50
ACC012R50
0.188 (4.78)
0.470 (11.94)
0.540 (13.72)
0.615 (15.62)
Copper Clad Aluminum
Corrugated Copper
10
40
0.46 (1.51)
0.39 (1.28)
4
22 (72.12)
0.057 (0.187)
8
1.25 (19.0)
1.13 (24.3)
50
94%
2 (50.8)
5 (127)
0.19 (0.28)
3.0 (4.1)
275 (125)
110 (2.0)
15
20
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
+5 to 194 (-15 to 90)
Attenuation
dB/100 ft dB/100m
Avg. Pwr.
kW
2.13
100
0.65
4.82
4.69
450
1.43
2.21
4.99
500
1.52
2.10
5.38
600
1.64
1.91
5.74
700
1.75
1.76
6.13
800
1.87
1.68
6.49
900
1.98
1.55
6.69
960
2.04
1.49
6.89
1000
2.10
1.46
8.59
1500
2.62
1.18
9.15
1700
2.79
1.10
9.45
1800
2.88
1.07
9.87
1950
3.01
1.02
10.00
2000
3.05
1.01
10.30
2100
3.14
0.99
10.59
2200
3.23
0.96
10.92
2300
3.33
0.94
11.22
2400conditions:3.42
0.91
Standard
o
2500
3.48
For attenuation,
VSWR
1.0, ambient11.41
temperature 200.90
C
o
(68 F)
11.97
2700
3.65
0.86
12.56
3000 power, VSWR
3.83 1.0, ambient
For average
temperature0.81
40oC
o
o
(104o3300
F), inner conductor
temperature
100
C
(212
F),
no
13.19
4.02
0.76
solar loading
13.38
3400
4.08
0.66
14.60
Regulatory
4000 Compliance/Certifications:
4.45
0.69
RoHS 2011/65/EU compliant
16.40
4900
5.00
0.60
TL 9000
H-V – All cables
manufactured
under
16.60
5000
5.06designed and
0.60
this quality management system
17.52
5200
5.34
0.58
100%
made in USA 5.48
17.97
5300
0.57
19.35
5600
5.90
0.53
Standard conditions:
For attenuation, VSWR 1.0, ambient temperature 20oC
(68oF)
For average power, VSWR 1.0, ambient temperature 40oC
(104oF), inner conductor temperature 100oC (212oF), no
solar loading
Regulatory Compliance/Certifications:
RoHS 2011/65/EU compliant
TL 9000 H-V – All cables designed and manufactured under
this quality management system
100% made in USA
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
**Attenuation ± 10% at 68oF
5/15
CONNECTORS & TOOLS
Connectors
Trilogy offers a variety of connector types for AirCell® Transline, Radiating and Plenum coaxial cables. AirCell®
connectors are engineered and manufactured to the highest standards, achieving superior performance in all areas.
AirCell® connectors are available in both the male and female versions of type N and type 7/16 DIN connectors.
Connectors can be installed on AirCell® coaxial cable quickly, easily and consistently. Standard coring tools prepare
the inner and outer conductors for connectorization. The smooth-wall construction and high strength jacket provide
for an optimum electrical and mechanical interface between connector and cable.
Advantages of AirCell® Connectors
Ease of Installation
AirCell® connectors drastically reduce installation time and eliminate the soldering process. Instead of using a
connector requiring highly accurate preparation measurements, AirCell® connectors can be attached in less
than two minutes with unique AirCell® coring tools. One of the best features of AirCell® connectors is that
they are designed for installers who do not need to be specially trained for installing connectors.
Completely Weatherproof for Long Life and Consistent Performance
The AirCell® connector has the highest level of resistance to water migration. This is accomplished through a
unique design, which attaches the connector to both the outer conductor and the jacket. AirCell® connectors
incorporate O-ring seals at critical junctions to keep moisture out of the interface and maintain their excellent
electrical performance.
Superior Resistance to Connect Pull-Off Provides Long-term Mechanical Integrity
It takes an excess of 900 pounds to separate the connector from the cable before electrical continuity breaks.
As a result, AirCell® connectors ensure long-term mechanical integrity.
Low Intermodulation and VSWR
AirCell® connectors achieve the highest level of return loss stability performance in the industry due to their
unique design. During attachment, the silver plated connector pin is compressed onto the center conductor of
the cable. As the connector is tightened, multiple annular teeth are compressed with extremely high normal forces
onto the center conductor of the cable, producing a tight connection that promotes consistently low VSWR, and
minimizes intermodulation problems.
Corrosion Resistant
AirCell® connectors are constructed of corrosion resistant metals that are compatible with AirCell® cables for
long term corrosion protection in outdoor applications. Trilogy uses special plating on its solid brass connectors
to reduce the effects of corrosion. The RF current carrying surfaces are silver-plated on both DIN and N-type
connectors, which ensures that all metals behave well together.
Designed for AirCell® Cables
AirCell® connectors are designed to work integrally with AirCell® cables to optimize the electrical and mechanical
performance of the transmission line system.
55
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
CONNECTORS & TOOLS
Connectors
AirCell® connectors and cable are designed to work integrally to provide the lowest VSWR in the industry. Connectors
are silver-plated at electrical contact interfaces. The design of the AirCell® connectors also provides the highest
structural integrity between cable and connector, as well as minimizes intermodulation concerns.
Type N and DIN Connectors
AirCell® Type N and Din connectors offer long term
performance and reliability, which translates into long
term cost savings. Both interfaces offer many
advantages:
DIN Connector Advantages
• Improved intermodulation performance
• Handles four times the power requirements
versus N-type connector
• Consistent and improved VSWR performance
• Ease of attachment and installation
• Corrosion resistant/durable construction
• Long-term mechanical integrity
• Silver-plated bodies and silver-plated electrical contacts
• Completely weatherproof connection
The pictures below show the Type N and Din connector interfaces and body styles available for AirCell® cables.
In many cases, a single picture is used to represent several similar connectors. See the Connector Selection
Guide for details.
AirCell® 1-5/8" Type N Female Connector
AirCell® 1-5/8" 7/16 DIN Female Connector
AirCell® 1/2" Type N Male Connector
AirCell® 1/2" 7/16 DIN Male Connector
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
56
CONNECTORS & TOOLS
Premium Performance Connectors
Premium Performance Connectors
O-Ring
The EPDM ozone-resistant O-Rings used in AirCell® connectors
create a waterproof seal, ensuring that water will not enter at the
connection and degrade the cable.
Center Conductor Seizing Mechanism
The metal-to-metal positive stop created by Trilogy’s Center and
Outer Conductor seizing mechanism prevents over tightening, maintains optimum seizure from jacket on through to center conductor,
and assures reliable performance.
Two Piece Construction
Having only two conductor pieces to deal with promotes fast,
reliable connectorization, reducing the possibility of human errors.
Silver Plated Contact Surfaces
All RF contact surfaces on Trilogy’s AirCell® connectors are silver
plated to reduce intermodulation, promote contact resistance over
time, and resist tarnish.
O-Ring
The EPDM ozone-resistant O-Rings used in AirCell® connectors
create a waterproof seal, ensuring that water will not enter at the
connection and degrade the cable.
Outer Conductor Seizing Mechanism
The metal-to-metal positive stop created by Trilogy’s Center and
Outer Conductor seizing mechanism prevents over tightening, maintains optimum seizure from jacket on through to center conductor,
and assures reliable performance.
57
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
AirCell
®
Cable Type CONNECTORS & TOOLS
Connector Selection Guide
Available Connector Interface
N Male N Female 7/16 DIN Female 7/16 DIN Male Transline AirCell® 50‐Ohm Transline AT012J50 1/2” Transmission Line, 50 Ohm, Black Polyethylene Jacket
1/2” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT012FX50 IEC332‐1 1/2” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT012F50 IEC332‐1, MSHA 1/2” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT012FV50 IEC332‐1, IEC332‐3C, UL 1685‐12 (FT4/IEEE1202, NFPA‐130) 1/2” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT012R50 IEC332‐1,IEC332‐3C, UL‐1666, CMR AT058J50 5/8” Transmission Line, 50 Ohm, Black Polyethylene Jacket
5/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT058FX50 IEC332‐1 5/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT058FV50 IEC332‐1, IEC332‐3C, UL 1685‐12 (FT4/IEEE1202, NFPA‐130) 5/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant AT058R50 Jacket,IEC332‐1,IEC332‐3C,UL‐1666, CMR AT078U50 7/8" Transmission Line, 50 Ohm, Unjacketed AT078J50 7/8” Transmission Line, 50 Ohm, Black Polyethylene Jacket
7/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT078FX50 IEC332‐1 7/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT078FV50 IEC332‐1, IEC332‐3C, UL 1685‐12 (FT4/IEEE1202, NFPA‐130) 7/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT078R50 IEC332‐1,IEC332‐3C,UL‐1666, CMR AT114J50 1‐1/4” Transmission Line, 50 Ohm, Black Polyethylene Jacket
1‐1/4” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT114FX50 IEC332‐1 1‐1/4” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT114FV50 IEC332‐1, IEC332‐3C, UL 1685‐12 (FT4/IEEE1202, NFPA‐130) 1‐1/4” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT114R50 IEC332‐1,IEC332‐3C,UL‐1666, CMR AT158J50 1‐5/8” Transmission Line, 50 Ohm, Black Polyethylene Jacket
1‐5/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT158FX50 IEC332‐1 1‐5/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT158FV50 IEC332‐1, IEC332‐3C, UL 1685‐12 (FT4/IEEE1202, NFPA‐130) 1‐5/8” Transmission Line, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant AT158R50 Jacket, IEC332‐1,IEC332‐3C,UL‐1666, CMR AirCell® 50‐Ohm Ultra‐Flex AU012J50 1/2" Ultra‐Flex, 50 Ohm, Corrugated, Black Polyethylene Jacket
1/2” Ultra‐Flex, 50 Ohm, Corrugated, Low‐Smoke, Non‐Halogenated, Fire Retardant AU012R50 Jacket, IEC332‐1, IEC332‐3C ,UL‐1666, CMR NMA01250
Product Code
NFA01250 DMA01250
DFA01250
NMA01250 NFA01250 DMA01250 DFA01250 NMA01250 NFA01250 DMA01250 DFA01250 NMA01250 NFA01250 DMA01250 DFA01250 NMA01250 NFA01250 DMA01250 DFA01250 NMA05850
NFA05850 DMA05850‐2G
DFA05850‐2G
NMA05850 NFA05850 DMA05850‐2G DFA05850‐2G NMA05850 NFA05850 DMA05850‐2G DFA05850‐2G NMA05850 NFA05850 DMA05850‐2G DFA05850‐2G NMA07850
NMA07850
NFA07850 NFA07850 DMA07850
DMA07850
DFA07850
DFA07850
NMA07850 NFA07850 DMA07850 DFA07850 NMA07850 NFA07850 DMA07850 DFA07850 NMA07850 NFA07850 DMA07850 DFA07850 NMA11450
NFA11450 DMA11450
DFA11450
NMA11450 NFA11450 DMA11450 DFA11450 NMA11450 NFA11450 DMA11450 DFA11450 NMA11450 NFA11450 DMA11450 DFA11450 NMA15850
NFA15850 DMA15850
DFA15850
NMA15850 NFA15850 DMA15850 DFA15850 NMA15850 NFA15850 DMA15850 DFA15850 NMA15850 NFA15850 DMA15850 DFA15850 NMP01250
Product Code
NFP01250 DMP01250
DFP01250
NMP01250 NFP01250 DFP01250 NMA01275
Product Code
NFA01275 NMA01275 NFA01275 NMA01275 NFA01275 NMA01275 NFA01275 NMA05875
NFA05875 NMA05875 NMA05875 DMP01250 AirCell® 75‐Ohm Transline AT012J75 1/2” Transmission Line, 75 Ohm, Black Polyethylene Jacket
1/2" Transmission Line, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT012FX75 IEC332‐1 1/2” Transmission Line, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT012F75 MSHA 1/2” Transmission Line, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket. AT012R75 UL‐1666, CMR AT058J75 5/8” Transmission Line, 75 Ohm, Black Polyethylene Jacket
5/8” Transmission Line, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT058FX75 IEC332‐1 5/8” Transmission Line, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket,
AT058R75 UL‐1666, CMR NFA05875 NFA05875 Cable Type Available Connector Interface
N Male N Female 7/16 DIN Female 7/16 DIN Male AirCell® 75‐Ohm Transline AT078J75 7/8” Transmission Line, 75 Ohm, Black Polyethylene Jacket
7/8” Transmission Line, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, AT078FX75 IEC332‐1 7/8” Transmission Line, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket,
AT078R75 UL‐1666, CMR Radiating AirCell® 50‐Ohm Radiating AR012J50 1/2” Radiating, 50 Ohm, Black Polyethylene Jacket AR012FX50 1/2" Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1
1/2” Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR012F50 MSHA 1/2” Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR012R50 IEC332‐3C ,UL‐1666, CMR AR058J50 5/8” Radiating, 50 Ohm, Black Polyethylene Jacket AR058FX50 5/8" Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1
5/8” Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR058R50 IEC332‐3C ,UL‐1666, CMR AR078J50 7/8” Radiating, 50 Ohm, Black Polyethylene Jacket AR078FX50 7/8" Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1
7/8” Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR078R50 IEC332‐3C , UL‐1666, UL 1685‐12 (FT4/IEEE1202, NFPA‐130), CMR AR114J50 1‐1/4” Radiating, 50 Ohm, Black Polyethylene Jacket 1‐1/4" Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐
AR114FX50 1 1‐1/4” Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐
AR114R50 1, IEC332‐3C ,UL‐1666, CMR AR158J50 1‐5/8” Radiating, 50 Ohm, Black Polyethylene Jacket 1‐5/8" Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐
AR158FX50 1 1‐5/8” Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐
AR158FV50 1, IEC332‐3C, UL 1685‐12 (FT4/IEEE1202, NFPA‐130) 1‐5/8” Radiating, 50 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐
AR158R50 1, IEC332‐3C ,UL‐1666, CMR AirCell® 75‐Ohm Radiating AR012J75 1/2” Radiating, 75 Ohm, Black Polyethylene Jacket AR012FX75 1/2" Radiating, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1
1/2” Radiating, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR012F75 MSHA 1/2” Radiating, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR012R75 IEC332‐3C ,UL‐1666, CMR AR058J75 5/8” Radiating, 75 Ohm, Black Polyethylene Jacket AR058FX75 5/8" Radiating, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1
5/8” Radiating, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR058R75 IEC332‐3C, UL‐1666, CMR AR078J75 7/8” Radiating, 75 Ohm, Black Polyethylene Jacket AR078FX75 7/8" Radiating, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1
7/8” Radiating, 75 Ohm, Low‐Smoke, Non‐Halogenated, Fire Retardant Jacket, IEC332‐1, AR078R75 IEC332‐3C ,UL‐1666, CMR Plenum NMA07875
Product Code
NFA07875 NMA07875 NFA07875 NMA07875 NFA07875 NMA01250
NMA01250
Product Code
NFA01250 DMA01250
NFA01250 DMA01250
DFA01250
DFA01250
NMA01250 NFA01250 DMA01250 DFA01250 NMA01250 NFA01250 DMA01250 DFA01250 NMA05850
NMA05850
NFA05850 NFA05850 DMA05850‐2G
DMA05850‐2G
DFA05850‐2G
DFA05850‐2G
NMA05850 NFA05850 DMA05850‐2G DFA05850‐2G NMA07850
NMA07850
NFA07850 NFA07850 DMA07850
DMA07850
DFA07850
DFA07850
NMA07850 NFA07850 DMA07850 DFA07850 NMA11450
NFA11450 DMA11450
DFA11450
NMA11450 NFA11450 DMA11450 DFA11450 NMA11450 NFA11450 DMA11450 DFA11450 NMA15850
NFA15850 DMA15850
DFA15850
NMA15850 NFA15850 DMA15850 DFA15850 NMA15850 NFA15850 DMA15850 DFA15850 NMA15850 NFA15850 DMA15850 DFA15850 NMA01275
NMA01275
Product Code
NFA01275 NFA01275 NMA01275 NFA01275 NMA01275 NFA01275 NMA05875
NMA05875
NFA05875 NFA05875 NMA05875 NFA05875 NMA07875
NMA07875
NFA07875 NFA07875 NMA07875 AirCell® 50‐Ohm Plenum AP6012J50 1/2" Plenum, 50 Ohm, Corrugated (6 GHz), Jacketed CMP (UL‐910, UL‐444), Canadian CSA 22.2/FT6 APC012J50 1/2” Plenum, 50 Ohm, Corrugated, Copper Outer Conductor, Jacketed CMP (UL‐910, UL‐
444), Canadian CSA 22.2/FT6 AirCell® 50‐Ohm Plenum Radiating 1/2” Plenum Radiating, 50 Ohm, Corrugated, Jacketed CMP (UL‐910, UL‐444), Canadian AQ012J50 CSA 22.2/FT6 1/2” Plenum Radiating, 50 Ohm, Corrugated, Copper Outer Conductor, Jacketed CMP AQC012J50 (UL‐910, UL‐444), Canadian CSA 22.2/FT6 AirCell® 75‐Ohm Plenum AP012J75 1/2” Plenum, 75 Ohm, Corrugated, Jacketed UL‐910, CATVP AirCell® 50‐Ohm Conduit AP012U50 1/2” Conduit Cable, 50 Ohm, Corrugated, UL‐444 NFA07875 NMP01250,
NMP01250‐
PIM NMP01250,
NMP01250‐
PIM Product Code
NFP01250, DMP01250,
NFP01250‐
DMP01250‐ PIM PIM NFP01250, DMP01250, NFP01250‐
DMP01250‐ PIM PIM Product Code
DFP01250,
DFP01250‐
PIM DFP01250, DFP01250‐
PIM NMP01250 NFP01250 DMP01250 DFP01250 NMP01250 NFP01250 DMP01250 DFP01250 NMP01275 NMP01250,
NMP01250‐
PIM Product Code
NFP01275 DMP01275 Product Code
NFP01250, DMP01250, NFP01250‐
DMP01250‐ PIM PIM DFP01275 DFP01250, DFP01250‐
PIM AirCell
®
Connectors & Tools
Connector Installation Instructions
For AirCell® Transline and Radiating Cables -– 1-1/4” & 1-5/8” 50 Ohm
1
For use with Power Prep Tools CT11450AIO, CT15850AIO, CT11450P, and CT15850P
AirCell connectors are designed specifically for use with Trilogy’s AirCell 50 Ohm Transline and Radiating cables.
Instructions should be read thoroughly prior to connector installation.
Power Prep Tool (Figure 1)
(CT11450AIO, CT15850AIO, CT11450P, CT15850P)
Additional Tools Required (Figure 2)
Power Drill
3M Scotchbrite Pad
Heat Shrink (or Weatherproofing Kit)
File
Razor Knife
Adjustable Wrenches
Small Ruler or Wire
Hacksaw
Figure 1
Figure 2
Prepare Cable for Connectorization
1)
2)
Locate the 1st disc by inserting small ruler or wire. Mark location on
jacket surface. Cut cable .125” behind disc using hacksaw (Figure 3).
Ensure that cable is straight for at least 10” from the end.
(Tools required: Small Ruler or Wire and Hacksaw)
For R and FV jacket types (J, F, and FX jacket types proceed to step 3).
a)
b)
Disk Location
Cut Here
Cut Here
5”
Remove 5” of jacket and tape using razor knife (Figure 4).
(Tool required: Razor Knife)
Figure 3
Figure 4
Figure 5
Figure 6
Remove jacket strip blade from Power Prep Tool.
3)
Insert cable end into Power Prep Tool and turn Power Prep Tool
clockwise to remove material (Figure 5). When Power Prep Tool no
longer cuts away material and spins freely, remove Power Prep Tool
while continuing to turn. (For J, F, and FX jacket types, this process will
remove .50” of jacket back. If necessary, remove any jacket remnants
with razor knife.) For R and FV jacket types, the exposed outer
conductor will be 4” when prep is completed.
(Tools required: Power Prep Tool and Razor Knife)
4)
Remove disc remnants from center conductor using razor knife
(Figure 6). Deburr center conductor using file. Remove adhesive with
3M Scotchbrite™ pad. Remove any remaining debris from cable end.
(Tools required: Razor Knife, File, and 3M Scotchbrite™ Pad)
0.5”
.50”
Connectorization
5)
Slide back-nut of connector onto prepared cable end. Center conductor
will protrude at least .50” (Figure 7). Slide front-nut onto center
conductor and hand-tighten connector by turning the back-nut.
Tighten the Connector
6)
Figure 7
Figure 8
Tighten the connector with wrenches by holding front-nut while turning
back-nut until back-nut reaches a positive stop (Figure 8).
(Tools required: Adjustable Wrenches)
Seal the Connector
7)
For R and FV jacket types, seal connector with appropriate
weatherproofing. Ensure that seal begins with connector and extends at
least 2” past the beginning of cable jacket (Figure 9).
Caution: For best electrical performance, do not damage the center or outer
conductors.
Figure 9
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
800 – TRILOGY (874 – 5649) • 601 – 932 – 4461 • www.trilogycoax.com
Rev. 8/3/12
AirCell
®
Connectors & Tools
Connector Installation Instructions
For AirCell® Plenum, Conduit,
and In-Conduit 1/2" 50 and 75 Ohm Cables
2
For use with Power Plenum Strip Tools PCT012 / PCT012-2
AirCell connectors are designed specifically for use with Trilogy’s AirCell
50 and 75 Ohm 1/2” cables. This instruction only applies when the Power
Plenum Strip Tool (PCT012 / PCT012-2) is used.
Instructions should be read thoroughly prior to connector installation.
Power Plenum Strip Tool* (Figure 1)
(PCT012 / PCT012-2)
Figure 1
Figure 2
Figure 3
Figure 4
Additional Tools Required (Figure 2)
Power Drill
Abrasive Pad
Inner Conductor Strip Tool (ICST)
Razor Knife
Adjustable Wrenches
Cable Cutter (TC63050)
Prepare Cable for Connectorization
1)
Squarely cut the cable using a cable cutter. Ensure that the cable is
straight for at least six inches behind the point where connector will attach.
Ensure that the center conductor is centered (Figure 3).
2)
Insert cable end into Power Plenum Strip Tool and turn Power Plenum
Strip Tool clockwise* to remove material (Figure 4). Operate the Power
Plenum Strip Tool in the 300-700 rpm range at steady speed. When Power
Plenum Strip Tool no longer cuts away material and spins freely, remove
Power Plenum Strip Tool while continuing to turn.
3)
Remove disk remnants from center conductor using razor knife or Inner
Conductor Strip Tool. Remove adhesive from center conductor using an
abrasive pad. Remove any remaining debris from inside of cable (Figure 5).
Connectorization
4)
Figure 5
Figure 6
Slide back-nut of connector onto prepared cable end. Back-nut should snap
into place. Center conductor will protrude .38” (Figure 6). Slide front-nut onto
center conductor. Hand-tighten connector by turning the back-nut.
Tighten the Connector
5)
Tighten the connector with wrenches by holding front-nut while turning
back-nut until back-nut reaches a positive stop (Figure 7).
Seal the Connector
6)
Seal connector with appropriate weatherproofing. Ensure that seal begins
with connector and extends at least 2” past the beginning of cable jacket
(Figure 8).
Figure 7
Figure 8
* Ensure that Power Plenum Strip Tool is free of debris prior to each use.
Caution: For best electrical performance, do not damage the center or outer
conductors.
Notice: Trilogy disclaims any liability or responsibility for the results of improper
or unsafe installation, inspection, maintenance, or removal practices.
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/16
AirCell
Connectors & Tools
®
Connector Installation Instructions
For AirCell® Plenum, Plenum Radiating,
and In-Conduit 1/2" 50 and 75 Ohm Cables
2A
For use with Manual Plenum Strip Tool PST012
AirCell connectors are designed specifically for use with Trilogy’s AirCell
50 and 75 Ohm 1/2” cables. This instruction only applies when the Manual
Plenum Strip (PST012) is used.
Instructions should be read thoroughly prior to connector installation.
Manual Plenum Strip Tool* (Figure 1)
(PST012)
Figure 1
Figure 2
Figure 3
Figure 4
Additional Tools Required (Figure 2)
Inner Conductor Strip Tool (ICST)
Abrasive Pad
Cable Cutter (TC63050)
Razor Knife
Adjustable Wrenches
Prepare Cable for Connectorization
1)
Locate the 1st disc by inserting smaller ruler or wire. Cut
cable with the cable cutter behind disc. Mark 2nd corrugation
valley behind disc by using the same method to locate the disc.
Ensure that cable is straight for at least 6” from the end.
2)
Attach Manual Plenum Strip Tool (Figure 3). Ensure arrow on
tool points to cable end. Pinch tool in place and spin until outer
conductor is cut through. Pinch blade end together and spin
once more.
3)
Remove jacket and outer conductor (Figure 4). Remove disk
remnants from center conductor using Razor Knife or Inner
Conductor Strip Tool (Figure 5). Remove adhesive from center
Cut Here
Figure 5
Figure 6
Figure 7
Figure 8
conductor using abrasive pad while holding the cable end down. Do
not allow debris to get inside the cable.
4)
Cut center conductor to .75” using gauge on the Manual Plenum
Strip Tool (Figure 6). Deburr center conductor with Inner
Conductor Strip Tool. Ensure that the inside of cable is free of
.38
”
debris.
Connectorization
5)
Slide back-nut of connector onto prepared cable end. Back-nut
should snap into place. Center conductor will protrude .38”
(Figure 7). Slide front-nut onto center conductor. Hand-tighten
connector by turning the back-nut (Figure 8).
Tighten the Connector
6)
Tighten the connector with wrenches by holding front-nut while
turning back-nut until back-nut reaches a positive stop (Figure 9).
Figure 9
* Ensure that Manual Plenum Strip Tool is free of debris prior to each use.
Caution: For best electrical performance, do not damage the center or outer
conductors.
Notice: Trilogy disclaims any liability or responsibility for the results of improper
or unsafe installation, inspection, maintenance, or removal practices.
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
4/16
AirCell
®
CONNECTORS & TOOLS
Connector Installation Instructions
For AirCell® Plenum 1/2” 75 Ohm Cables
2B
For use with cable prep tools TC1000 & TC10099 (Manual Tools) and F & PIN Connectors (FMP/PMP01275)
AirCell connectors are designed specifically for use with Trilogy’s AirCell 75 Ohm 1/2” cables. This instruction only applies
when the Tube Cutter (TC1000) and Razor Knife (TC10099) are used. Instructions should be read thoroughly prior to
connector installation.
Installation Tools
Tube Cutter (TC1000)
Needle Nose Pliers
Small Ruler or Wire
Adjustable Wrenches
Razor Knife (TC10099)
3M Scotchbrite™ Pad
File
Prepare Cable for Connectorization
1)
Cut to the center conductor and remove .75” of material
(Figure 1). Ensure that cable is straight for at least 6” from the end.
(Tool required: Tube Cutter)
.75”
st
2)
Locate the 1 disc by inserting smaller ruler or wire
3)
Trim center conductor to .75” (Figure 3). Deburr center
conductor with file. Remove disc with razor knife and remove
adhesive from center conductor with 3M Scotchbrite™ pad.
(Tools required: Needle nose pliers, File, Razor Knife, and 3M
Scotchbrite™ Pad)
4)
Cut Here
(Figure 2). Cut in the 2nd corrugation valley behind disc and
remove jacket and outer conductor.
(Tools required: Small Ruler or Wire and Tube Cutter)
Figure 1
Remove .63” of jacket from the outer conductor (Figure 3).
Remove any remaining debris from inside ofcable.
(Tools required: Razor knife)
Figure 2
.38”
Connectorization
5)
Slide back-nut of connector onto cable end. Center
conductor should protrude .38” (Figure 4). Slide front-nut onto
center conductor and hand-tighten connector by turning the
back-nut (Figure 5).
.75”
Tighten the Connector
6)
.63”
Figure 3
Figure 4
Figure 5
Figure 6
Tighten the connector with wrenches by holding front-nut
while turning back-nut until back-nut reaches a positive stop
(Figure 6).
(Tools required: adjustable wrenches)
Caution: For best electrical performance, do not damage the center or outer
conductors.
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
800 – TRILOGY (874 – 5649) • 601 – 932 – 4461 • www.trilogycoax.com
Rev. 8/3/12
AirCell
Connectors & Tools
®
Connector Installation Instructions
For AirCell® Plenum, Conduit, and In-Conduit 1/2" 50 Ohm Cables
2C
For use with Plenum Strip Tool PCT012-PIM and PIM Connector
AirCell connectors are designed specifically for use with Trilogy’s AirCell
50 Ohm 1/2” cables. This instruction only applies when the Plenum Strip
Tool (PCT012-PIM) is used.
Instructions should be read thoroughly prior to connector installation.
Plenum Strip Tool* (Figure 1)
(PCT012-PIM)
Additional Tools Required (Figure 2)
Cable Cutter (TC63050)
Abrasive Pad
Razor Knife
Adjustable Wrenches
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Prepare Cable for Connectorization
1)
Cut the cable while rotating the cable cutter to attain a rounded cable end.
Straighten the cable at least 12 inches from the cut.
2)
Remove 1 ¼ inch of jacket from the end of the cable. Insert a gauge into
the cable to determine the location of the next disc and mark the location on
the outer conductor.
3)
Cut the outer conductor with the cable cutter in the 2nd corrugation valley
behind the mark. Use a rotating motion to ensure the cable end is round
(Figure 3). Cut the center conductor flush with the outer conductor and
check that the center conductor remains centered (Figure 4).
4)
Slide the Plenum Strip Tool over the cable and begin turning the tool
clockwise (Figure 5). Continue turning the tool until the tool no longer cuts
away material. To remove the tool, continue to turn while pulling it from the
cable. Inspect the end of the cable to ensure the tool finalized its cut on a
corrugation peak (Figure 6). A correctly prepared cable end has 1 inch of
outer conductor exposed and 1/4 inch center conductor exposed.
5)
Remove any dielectric disc and adhesive from the center conductor using
the razor knife and abrasive pad while holding the cable end down. Do not
allow debris to get inside the cable.
Connectorization
6)
Slide the back half of the connector onto the cable. It should snap into the
first corrugation valley of the outer conductor (Figure 7).
7)
Pull the tool handle to separate the flaring tool from tool body (Figure 8).
Press the flaring tool against the cable and ensure that the flaring pin is
inside the outer conductor. Rotate the flaring tool to flare the outer
conductor. (Figure 9). Remove any remaining debris.
8)
Slide the front half of the connector onto the center conductor. Handtighten the connector halves together by turning only the back half.
Tighten the Connector
9)
Continue tightening the connector with wrenches by holding the front half
while turning the back half until the connector reaches a positive stop
(Figure 10).
* Ensure that Plenum Strip Tool is free of debris prior to each use.
Caution: For best electrical performance, do not damage the center or outer
conductors.
Figure 9
Figure 10
Notice: Trilogy disclaims any liability or responsibility for the results of improper
or unsafe installation, inspection, maintenance, or removal practices.
8 0 0 - T R I LO G Y ( 8 74 –5 6 4 9 ) • 6 0 1 - 93 2 - 44 6 1 • w w w . t r i l o g y c o a x . c o m
6/14
AirCell
®
CONNECTORS & TOOLS
Connector Installation Instructions
For AirCell® Transline and Radiating Cables – 1/2”, 5/8”, & 7/8” 50 Ohm
3
For use with Power Prep Tools CT01250AIO-2, CT05850AIO-2, and CT07850AIO-2
AirCell connectors are designed specifically for use with Trilogy’s AirCell 50 Ohm Transline and Radiating cables.
Instructions should be read thoroughly prior to connector installation.
Power Prep Tool (Figure 1)
(CT01250AIO-2, CT05850AIO-2, CT07850AIO-2)
Additional Tools Required (Figure 2)
Power Drill
3M Scotchbrite Pad
Heat Shrink (or Weatherproofing Kit)
File
Razor Knife
Adjustable Wrenches
Small Ruler or Wire
Hacksaw
Prepare Cable for Connectorization
1)
2)
Locate the 1st disc by inserting small ruler or wire. Mark location on jacket
surface. Cut right in front of disc using hacksaw (Figure 3). Ensure that cable
is straight for at least 10” from the end.
(Tools required: Small Ruler or Wire and Hacksaw)
Figure 1
Figure 2
Cut Here
For R and FV jacket types* (J, F, and FX jacket types proceed to step 3).
a)
Remove 5” of jacket and tape using razor knife (Figure 4).
(Tool required: Razor Knife)
b)
Remove jacket strip blade from Power Prep Tool.
3)
Insert cable end into Power Prep Tool and turn Power Prep Tool
clockwise to remove material (Figure 5). When Power Prep Tool no longer
cuts away material and spins freely, remove Power Prep Tool while continuing
to turn. (For J, F, and FX jacket types, this process will remove .50” of jacket back for 1/2” and 7/8” cable or .63” of jacket back for 5/8” cable. If necessary,
remove any jacket remnants with razor knife.) For R and FV jacket types,
the exposed outer conductor will be 4.25” for 1/2” cable or 4.50” for 5/8” and 7/8” cables when prep is completed.
(Tools required: Power Prep Tool and Razor Knife)
4)
Remove disc remnants from center conductor using razor knife. Deburr
center conductor using file. Remove adhesive with 3M Scotchbrite™ pad.
Remove any remaining debris from cable end.
(Tools required: Razor Knife, File, and 3M Scotchbrite™ Pad)
Disc Location
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Connectorization
5)
Slide back-nut of connector onto prepared cable end. Center conductor will
protrude at least .38” for 1/2” cable or .25” for 5/8” and 7/8” cables (Figure 6).
Slide front-nut onto center conductor and hand-tighten connector by turning
the back-nut.
Tighten the Connector
6)
Tighten the connector with wrenches by holding front-nut while turning
back-nut until back-nut reaches a positive stop (Figure 7).
(Tools required: Adjustable Wrenches)
Seal the Connector
7)
For R and FV jacket types, seal connector with appropriate weatherproofing.
Ensure that seal begins with connector and extends at least 2” past the beginning of cable jacket (Figure 8).
* For AirCell® Radiating Double Jacketed Cables please contact Trilogy’s Tech Support Department
Caution: For best electrical performance, do not damage the center or outer conductors.
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
800 – TRILOGY (874 – 5649) • 601 – 932 – 4461 • www.trilogycoax.com
Rev. 8/3/12
AirCell
®
CONNECTORS & TOOLS
Connector Installation Instructions
For AirCell® Transline and Radiating Cables - 5/8” 50 Ohm, and 1/2”, 5/8”, & 7/8” 75 Ohm
3A
For use with Power Prep Tools CT01250AIO, CT05850AIO, and CT07850AIO
AirCell connectors are designed specifically for use with Trilogy’s AirCell 50 Ohm Transline and Radiating cables.
Instructions should be read thoroughly prior to connector installation.
Power Prep Tool (Figure 1)
(CT01250AIO, CT05850AIO, CT07850AIO)
Additional Tools Required (Figure 2)
Power Drill
3M Scotchbrite Pad
Heat Shrink (or Weatherproofing Kit)
File
Razor Knife
Adjustable Wrenches
Small Ruler or Wire
Hacksaw
Prepare Cable for Connectorization
1)
Cut cable squarely using a hacksaw. Ensure that cable is straight for at least
10” from the end.
(Tool required: Hacksaw)
2)
For R and FV jacket types (J, F, and FX jacket types proceed to step 3).
Remove 5” of jacket and tape using razor knife (Figure 3). Remove jacket strip
blade from Power Prep Tool and proceed to Step 4.
(Tool required: Razor Knife).
3)
For radiating cables* (otherwise proceed to step 4).
Remove .50” of jacket using razor knife (Figure 3). Remove jacket strip blade
from Power Prep Tool.
(Tool required: Razor Knife)
4)
Insert cable end into Power Prep Tool and turn Power Prep Tool clockwise
(Figure 4). Ensure that center conductor passes into hollow center of coring bit.
When Power Prep Tool no longer cuts away material and spins freely, remove
Power Prep Tool while continuing to turn. (For J, F, and FX jacket types, this
process will remove .50” of jacket back for 1/2” and 7/8” cable or .63” of jacket back for 5/8” cable. If necessary, remove any jacket remnants with razor knife.)
For R and FV jacket types, the exposed outer conductor will be 3.88” for 1/2” cable or 3.63” for 5/8” and 7/8” cables when prep is completed. (Tool required: Power Prep Tool)
5)
Remove disc remnants from center conductor using razor knife. Deburr
center conductor using file. Remove adhesive with 3M Scotchbrite™ pad.
Remove any remaining debris from cable end.
(Tools required: Razor Knife, File, and 3M Scotchbrite™ Pad)
Connectorization
6)
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Slide back-nut onto cable end. The plastic insert should be firmly secured inside
cable and back-nut will slide back and forth. Center conductor should protrude
slightly when back-nut is fully forward (Figure 5). Slide front-nut onto center
conductor and hand-tighten connector by turning the back-nut (Figure 6).
Tighten the Connector
7)
Tighten the connector with wrenches by holding front-nut while turning backnut until back-nut reaches a positive stop (Figure 7).
Seal the Connector
8)
For R and FV jacket types, seal connector with appropriate weatherproofing.
Ensure that seal begins with connector and extends at least 2” past the beginning of cable jacket (Figure 8).
* For AirCell® Radiating Double Jacketed Cables please contact Trilogy’s Tech Support Department
Caution: For best electrical performance, do not damage the center or outer conductors.
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
800 – TRILOGY (874 – 5649) • 601 – 932 – 4461 • www.trilogycoax.com
Rev. 8/3/12
AirCell
®
CONNECTORS & TOOLS
Connector Installation Instructions
For AirCell® Transline and Radiating Cables – 1/2”, 5/8”, & 7/8” 75 Ohm
3B
For use with cable prep tools TC1000 & TC10099 (Manual) and N Connectors
AirCell connectors are designed specifically for use with Trilogy’s AirCell 75 Ohm Transline and Radiating cables.
Instructions should be read thoroughly prior to connector installation.
Installation Tools
Tube Cutter (TC1000)
File
Adjustable Wrenches
3M Scotchbrite Pad
Razor Knife (TC10099)
Hacksaw
Small Ruler or Wire
Heat Shrink (or Weatherproofing Kit)
Prepare Cable for Connectorization
1)
2)
3)
4)
Locate the 1st disc by inserting small ruler or wire. Mark location on
jacket surface. Cut right in front of disc using hacksaw (Figure 1). Ensure
that cable is straight for at least 10” from the end.
(Tools required: Small Ruler or Wire and Hacksaw)
Cut 3/4” of outer conductor and jacket using tube cutter. Stop cutting when
outer conductor is cut through. Do not crush cable end. Cut through the
dielectric tube using razor knife and remove material (Figure 2).
(Tools required: Tube Cutter and Razor Knife)
Disc Location
Remove cable jacket (Figure 3)
a)
For standard jacket cables, remove 5/8” of jacket for 1/2”
cable or 1” of jacket for 5/8” and 7/8” cables.
(Tool required: Razor Knife)
b)
For riser rated cables, remove 5” of jacket and tape using
razor knife.
(Tool required: Razor Knife)
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Remove disc remnants from center conductor using razor knife. Deburr
center conductor using file. Remove adhesive with 3M Scotchbrite™ pad.
Remove any remaining debris from cable end.
(Tools required: Razor Knife, File, and 3M Scotchbrite™ Pad)
Connectorization
5)
Cut Here
Slide back-nut of connector onto prepared cable end. Center conductor will
protrude at least 3/8” for 1/2” cable or 1/4” for 5/8” and 7/8” cables
(Figure 4). Slide front-nut onto center conductor and hand-tighten
connector by turning the back-nut.
Tighten the Connector
6)
Tighten the connector with wrenches by holding the front-nut while turning
back-nut until back-nut reaches positive stop (Figure 5).
(Tools required: Adjustable Wrenches)
Seal the Connector
7)
For riser rated cables, seal connector with appropriate weatherproofing.
Ensure that seal begins with connector and extends at least 2” past the
beginning of cable jacket (Figure 6).
Caution: For best electrical performance, do not damage the center or outer
conductors.
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
800 – TRILOGY (874 – 5649) • 601 – 932 – 4461 • www.trilogycoax.com
Rev. 8/3/12
AirCell
®
Connectors & Tools
Power Tools – Blade Replacement
Blade Replacement Instructions for AirCell® Power Tools
4
r use with PCT012, CT01250AIO-2, CT05850AIO-2, CT07850AIO-2
For use with PCT012, CT01250AIO-2, CT05850AIO-2, CT07850AIO-2
Instructions should be read thoroughly prior to blade replacement.
Additional Tools Required
Hex Wrench, 3/32
Hex Wrench, 5/64
Blade Replacement Kit CTAIO-2RB/4PK
(2) CB6667
(2) CB26
Blade Replacement
Figure 1
Figure 2
Jacket Strip Blade CB6667
Remove blade by loosening the socket head cap screw with
a 3/32 hex wrench (Figure 1). Blade is slotted and should be
positioned completely towards the center of the tool. Install
new blade by tightening the socket head cap screw securely.
Dielectric Blade CB6667
Remove blade by loosening the socket head cap screw with
a 3/32 hex wrench (Figure 2). Blade is slotted and should be
positioned completely towards the center of the tool. Install
new blade by tightening the socket head cap screw securely.
Figure 3
Outer Conductor Chamfer CB26
Remove blade by loosening the button head socket screw
with a 5/64 hex wrench (Figure 3). Blade requires no
adjustment. Install new blade by tightening the button head
socket screw securely.
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
1/14
AirCell
®
Connectors & Tools
Power Tools – Blade Replacement
Blade Replacement Instructions for AirCell® Power Tools
5
r use with PCT012, CT01250AIO-2, CT05850AIO-2, CT07850AIO-2
For use with PCT012-2
Instructions should be read thoroughly prior to blade replacement.
Additional Tools Required
Hex Wrench, 3/32
Hex Wrench, 5/64
Blade Replacement Kit PCT012-2RB/4PK
(2) CB6667
(2) CB26
Blade Replacement
Figure 1
Figure 2
Jacket Strip Blade CB6667
Remove blade by loosening the socket head cap screw with
a 3/32 hex wrench (Figure 1). Blade is slotted and should be
positioned completely away from the center of the tool. Install
new blade by tightening the socket head cap screw securely.
Dielectric Blade CB26
Remove blade by loosening the button head socket screw
with a 5/64 hex wrench (Figure 2). Blade requires no
adjustment. Install new blade by tightening the button head
socket screw securely.
Figure 3
Outer Conductor Chamfer CB26
Remove blade by loosening the button head socket screw
with a 5/64 hex wrench (Figure 3). Blade requires no
adjustment. Install new blade by tightening the button head
socket screw securely.
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
1/14
AirCell
®
Connectors & Tools
Power Tools – Blade Replacement
Blade Replacement Instructions for AirCell® Power Tools
6
r use with PCT012, CT01250AIO-2, CT05850AIO-2, CT07850AIO-2
For use with CT11450P and CT15850P
Instructions should be read thoroughly prior to blade replacement.
Additional Tools Required
Hex Wrench, 5/32
Blade Replacement Kit CT114/158RB/3PK
(3) CB214
Blade Replacement
Jacket Strip Blade CB214
Remove blade by loosening the socket head cap screw with
a 5/32 hex wrench (Figure 1). Blade requires no adjustment.
Install new blade by tightening the socket head cap screw
securely.
Figure 1
Figure 2
Outer Conductor Chamfer CB214
Remove blade by loosening the socket head cap screw with
a 5/32 hex wrench (Figure 2). Blade requires no adjustment.
Install new blade by tightening the socket head cap screw
securely.
Dielectric Blade CB214
Remove blade by loosening the socket head cap screw with
a 5/32 hex wrench (Figure 3). Blade requires no adjustment.
Install new blade by tightening the socket head cap screw
securely.
Figure 3
Notice: Trilogy disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
8 0 0- T R I L O G Y ( 8 74 – 5 6 49 ) • 6 0 1 - 93 2 - 4 4 61 • w ww . t r i l o gy c o ax . co m
1/14
CONNECTORS & TOOLS
Hardware and Accessories
Prep Tools for AirCell® Transline and Radiating Cable
AirCell® All-In-One Prep Tool is a unique cutting tool designed exclusively for AirCell® Transline and Radiating cable. Cable
installers can dramatically reduce cable preparation time by using Trilogy’s new All-In-One Prep Tool to aid in fast and
continuously reliable connectorization. This dependable tool is designed to ensure the most superior connectorization in the industry
by eliminating costly human errors. It simultaneously cuts back dielectric, and outer conductor to expose the correct center
conductor length, and strips the jacket back in one easy operation.
Description
Product Code
Wt. (lb.)
Prep Tool for 1/2" Cable
Prep Tool for 5/8" Cable
Prep Tool for 7/8" Cable
Prep Tool for 1-1/4" Cable
Prep Tool for 1-5/8" Cable
CT01250AIO-2
CT05850AIO-2
CT07850AIO-2
CT11450P
CT15850P
1.5
1.5
1.7
1.8
2.4
Tools for AirCell® Plenum Cable
AirCell Plenum cables can be easily prepared for connectorization using the following tool.
Description
Product Code
Wt. (lb.)
High Leverage Cable Cutter (pictured)
TC63050
1.2
Tube Cutter
TC1000
0.9
Knife-box Cutter
TC10099
0.7
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l o g y c o a x . c o m
68
CONNECTORS & TOOLS
Weather Proofing Instructions
Universal Weatherproofing Kit For AirCell“ Transline – 1/2", 5/8", 7/8", 1-1/4" and 1-5/8"
General Description
The Universal Weatherproofing Kit for AirCell® connectors includes mastic and electrical tapes that are applied to
provide a multi-layer, long-term environmental seal over multiple connections. The following instructions describe
the required procedure to install the Weatherproofing Kit over AirCell® connectors on coaxial cables.
Instructions should be read thoroughly prior to installation.
Installation Tools
Razor Knife (product code 10-099)
Weatherproofing Kit (product code WK-U)
1) Apply one layer of 2" x 20’ electrical tape over lapping each row
approximately 1/4". Tape layers should extend approximately 1"
past each end of connection and each layer should be tightly
wrapped to eliminate any void or air pockets.
2) Apply one layer of vinyl backed mastic overlapping each row
approximately 1/2". Mastic layer should overlap fist tape layer at
a minimum of 1/2" on each side of connection.
3) Apply three final layers of 3/4" x 44’ electrical tape overlapping
each row approximately 1/4". Tape layers should extend
approximately 1" past each end of connection and each layer
should be tightly wrapped to eliminate any void or air pockets.
The installation is complete at this point.
NOTE: Please refer to page 67 of Hardware and Accessories for
information on AirCell® 3M™ Cold Shrink™ Weatherproofing
Kit alternative method.
69
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
AirCell
®
Hardware & Accessories
Cable Hoisting & Attachments
Product Code
HG-12
HG-58
HG-78
HG-78L
HG-114
HG-114L
HG-158
HG-158L
Lace-up/Pre-Laced Hoisting Grips
Lace-up Hoisting Grip for 1/2” AirCell Coax
Lace-up Hoisting Grip for 5/8” AirCell Coax
Lace-up Hoisting Grip for 7/8” AirCell Coax
Pre-Laced Hoisting Grip for 7/8” AirCell Coax
Lace-up Hoisting Grip for 1-1/4” AirCell Coax
Pre-Laced Hoisting Grip for 1-1/4” AirCell Coax
Lace-up Hoisting Grip for 1-5/8” AirCell Coax
Pre-Laced Hoisting Grip for 1-5/8” AirCell Coax
Coax Support Blocks
CB-158
Mini Coax Support Blocks for 1-5/8” AirCell Coax
Galvanized Mounting Hardware Kits for Mini and Large Coax Support Blocks
HK-TSCB158
Hardware Kit for three 1-5/8” AirCell Support Blocks
Universal Round Member Hardware
RM-A100
RM-A200
RM-A300
RM-USBG
Round Member Adaptor 1”-2” OD
Round Member Adaptor 2”-3” OD
Round Member Adaptor 3”-4” OD
Universal Round Member Support Bracket, Galvanized Version
Galvanized Angle Adaptors
AA-GU
AA-38L
AA-US
AA-U
Universal Galvanized Angle Adaptor
Galvanized Angle Adaptor, Large Version w/ 3/8” Tapped Holes
Stainless Steel Angle Adaptors
Universal Stainless Steel Angle Adaptor, Snap In Version
Universal Stainless Steel Angle Adaptor
Self Locking Cable Hangers
CLC#15
CLC#20
CLC#25
CLC#28
CLC#40
CLC#51
Plastic Self-locking Cable Hangers for 1/2” AirCell Coax, All Jackets (Pkg of 100)
Plastic Self-locking Cable Hangers for 5/8” AirCell Coax, Standard & Fire Retardant
Jackets (Pkg of 100)
Plastic Self-locking Cable Hangers for 7/8" AirCell Coax, Unjacketed (Pkg of 50)
Plastic Self-locking Cable Hangers for 7/8” AirCell Coax, All Jackets (Pkg of 50)
Plastic Self-locking Cable Hangers for 1-1/4” AirCell Coax, All Jackets (Pkg of 25)
Plastic Self-locking Cable Hangers for 1-5/8” AirCell Coax, All Jackets (Pkg of 25)
AirCell
®
Hardware & Accessories
Cable Hoisting & Attachments
Flange/Stud
Product Code
CLC#LT101
Flange. Inserts into hanger slot. Use with 1/4"-20 stud or rod.
Spacers
CLC#LT45
Plastic Standoff Posts (Provides 2" standoff) Pkg of 100
Premium Cable Hangers
CLC#78P
Premium Plastic Radiating Cable Hanger for 7/8" AirCell Coax, All Jackets
CLC#114P
CLC#158P
Premium Plastic Radiating Cable Hanger for 1-1/4" AirCell Coax, All Jackets
Premium Plastic Radiating Cable Hanger for 1-5/8" AirCell Coax, All Jackets
Premium Plastic Spacers for CLC# 78P/114P/158P
CLC#SS
Premium Plastic 2" Stand-off Spacer
CLC#SS80
Premium Plastic 3" Stand-off Spacer
Premium Cable Hangers with Fire Safety Metal Collar
CLC#78M
Premium Radiating Cable Fire Safety Metal Collar Hanger for 7/8" AirCell Coax, All
Jackets
CLC#114M
Premium Radiating Cable Fire Safety Metal Collar Hanger for 1-1/4" AirCell Coax, All
Jackets
CLC#158M
Premium Radiating Cable Fire Safety Metal Collar Hanger for 1-5/8" AirCell Coax, All
Jackets
Premium Messenger Hangers
CLC#MSG78
CLC#MSG114
CLC#MSG158
Premium Plastic Radiating Cable Messenger Wire Hanger for 7/8" AirCell Coax, All
Jackets
Premium Plastic Radiating Cable Messenger Wire Hanger for 1-1/4" AirCell Coax, All
Jackets
Premium Plastic Radiating Cable Messenger Wire Hanger for 1-5/8" AirCell Coax, All
Jackets
AirCell
®
Hardware & Accessories
Cable Hoisting & Attachments
Product Code
Premium Stainless Spacers Hanger Kit for Premium Hangers and Metal Collar
CLC#SSM
Premium Stainless 2" Stand-off Spacer
CLC#SSM4
Premium Stainless 4" Stand-off Spacer
Stainless Steel Butterfly Hangers
BH-12
BH-58
BH-78
BH-114
BH-158
Butterfly Hanger for 1/2” AirCell Coax, No Hardware
Butterfly Hanger for 5/8” AirCell Coax, No Hardware
Butterfly Hanger for 7/8” AirCell Coax, No Hardware
Butterfly Hanger for 1-1/4” AirCell Coax, No Hardware
Butterfly Hanger for 1-5/8” AirCell Coax, No Hardware
Stainless Steel Butterfly Hanger Hardware
BHK-34-10
BHK-100-10
Hanger Hardware 3/8" x 3/4" Hex Bolt w/ Washer & Nut
Hanger Hardware 3/8" x 1" Hex Bolt w/ Washer & Nut
Universal Snap-in Hangers
SH-U12
SH-U58
Universal Snap-in Hanger for 1/2” AirCell Coax
Universal Snap-in Hanger for 5/8” AirCell Coax
SH-U78
Universal Snap-in Hanger for 7/8” AirCell Coax
SH-U114
SH-U158
Universal Snap-in Hanger for 1-1/4” AirCell Coax
Universal Snap-in Hanger for 1-5/8” AirCell Coax
Stackable Snap-in Hanger
SHS-158
Stackable Snap-in Hanger for 1-5/8" AirCell Coax
AirCell
®
Hardware & Accessories
Weatherproofing
Product Code
MT-461
AirCell® 3M™ Scotch Cote Spray Sealer
3M Scotch™ Cote Spray Sealer, 13oz. Can
Universal Weatherproofing Kit
WK-U
Universal Weatherproofing Kit
AirCell® 3M™ Cold Shrink Weatherproofing Kits
CSU-12158
Universal for All Cable Sizes
Cable Entry Kits
Cushion Inserts (Standard)
SC-12-1
SC-12-2
SC-58-1
SC-78-1
SC-158-1
Standard Port Cushion w/ 1 hole for 1/2” AirCell Coax
Standard Port Cushion w/ 2 holes for 1/2” AirCell Coax
Standard Port Cushion w/ 1 hole for 5/8” AirCell Coax
Standard Port Cushion w/ 1 hole for 7/8” AirCell Coax
Standard Port Cushion w/ 1 hole for 1-5/8” AirCell Coax
Feed-thru Boot Assemblies
BA-400
4" Boot Assembly, cushion not included
Ground Kits & Mounting Hardware
Universal Ground Buss Bar Kits
GB-02519T-U
GB-0420-U
Tin Plated, 1/4" x 2½" x 19½", with Universal Hardware Kit
Copper, 1/4" x 4" x 20", with Universal Hardware Kit
Standard Ground Kits
GK-S12AC
GK-S58AC
GK-S78AC
GK-S114/158AC
Std Ground Kit for 1/2” AirCell Coax
Std Ground Kit for 5/8” AirCell Coax
Std Ground Kit for 7/8” AirCell Coax
Std Ground Kit for 1-1/4” & 1-5/8" AirCell Coax
Terms and Conditions
Payment. On approved credit, net 30 days from date of invoice for domestic
transactions. 1.5% finance charge per month will be added after due date.
Trilogy will accept MasterCard, Visa and American Express cards.
An Irrevocable Letter Of Credit from a U.S. Bank or cash in advance in U.S. currencies is
required prior to International Transactions. All orders subject to acceptance of factory and
will be billed at price in effect at time of shipment
Product and Pricing. All prices are quoted in United States dollars, F.O.B. Plant,
excluding taxes and freight, in effect at time of order are also shown. . Prices, discounts
and terms and conditions are subject to change without notice.
Sales and Use Taxes. Trilogy will charge, collect and remit the appropriate sales and use
taxes in the states that Trilogy is registered for such taxes. Tax-exempt Customers can
contact our Customer Service for instruction on how to submit their sales tax exemption to
Trilogy prior to the order. Trilogy is not responsible for the collection or payment of any
foreign duties, tariffs or assessments.
Damaged or Lost Items. Customer may refuse damaged shipments that are visibly
damaged by indicating the damage on the receipt. Once the shipment is received, please
call Trilogy Customer Service to order a replacement product, and contact the transportation
company to file a claim.
Fifteen-Day Returns. Customer may return products within fifteen (15) days of receipt for
any reason (except if damaged from mishandle or misuse) for refund of the product purchase
price. A charge will be made if the product is not returned in saleable condition. Prior to
returning a product, you must call our Customer Service to obtain a Return Authorization
Number. The Customer is responsible for shipping charges on the returned product. When
the complete product is received at Trilogy, a credit will be issued. This policy does not
apply to custom orders or custom cut lengths.
ORDERING INFORMATION
Warranty
Trilogy Communications, Inc. ships all international, ocean, and other special transport as we do domestic shipping. However, lagging is
available at the customer’s request. For additional information regarding shipping information, please contact Trilogy’s Customer Service
Center at 1-800-874-5649.
Warranty
Trilogy Communications, Inc. warrants that its coaxial cable will be free from defects in material and workmanship. If any failure to conform
with this warranty is found within 30 days (in the case of any non-conformity discoverable through reasonable inspection) or within six
months (in the case of defects not discoverable through reasonable inspection) from the date of receipt of the product by purchaser,
and Trilogy is given immediate notification thereof,Trilogy, upon being satisfied of the existence of such non-conformity, will correct same
by replacement of the defective product or by making suitable repairs. If Trilogy is unable to correct such non-conformity by replacement
of the product or making suitable repairs, whether due to the nature of such non-conformity, the use made by the purchaser of the
product, or for any other reason, it will return to buyer the price set forth on the Invoice, or where appropriate, the unit price for such
number or quantity of products as shall have such non-conformity which Trilogy is unable to correct, upon Trilogy’s receipt of the nonconforming product F.O.B. its plant, provided, however, no product shall be returned to Trilogy without its express written consent, and
provided further, that such receipt of any non-conforming product will not be required where it is no longer possible for the purchaser
to return same to Trilogy. In warranting this product to be free from manufacturing defects,Trilogy makes no warranty and assumes no
liability for personal injury or the consequential and/or incidental damages based on misuse of cable or other products, use of coaxial
cable or other products for any use other than that intended by Trilogy and/or negligence in proper shipping or installation of the product
by any other person.Trilogy further makes no other warranties, express or implied, including implied warranties of merchantability
and/or fitness for a particular purpose.The warranty set forth herein provides the sole and exclusive warranty of Trilogy Communications,
Inc. and supersedes and supplants any oral representations or other warranties expressed or implied in connection with the sale of cable
or other products by Trilogy to the purchaser.This warranty does not extend to subsequent purchasers from the buyer, or buyer’s
successors and/or assigns.
Buyer’s exclusive remedy against Trilogy shall be as set forth in the proceeding paragraph. In no event shall Trilogy be liable to buyer, either
directly or by way of contribution or indemnity for direct, special, incidental or consequential damages such as, but not limited to, property
damage, loss of profit, damage based on loss of use of the product, or damages for cover, irrespective of whether the claim for any such
damages be based on warranty, express or implied, contract, tort or otherwise.Trilogy shall likewise not be liable for damages based on
cover, or consequential damages (including, but not limited to loss of profits or damages based upon loss of use of the product) for any
failure to or delay in the delivery due to acts of God, including, without limitation, floods, tornadoes, hurricanes, earthquakes or other
natural or weather conditions or accidents (whether or not contributed to by Trilogy’s negligence), strikes or other labor disputes (whether
against seller, its suppliers or carriers and whether or not due to any fault of Trilogy), delay of carriers, shortages of material, fuel or energy,
breakdown of equipment, orders, requirements or request of any government, government agency or any officer or official thereof, or
any similar causes, whether or not beyond Trilogy’s control. In the event that there is a delay in delivery due to such cause or causes,Trilogy
will have the option to cancel without any liability to buyer or to make delivery within a reasonable time after termination of the cause
or causes of the delay.
EXTENDED WATER MIGRATION WARRANTY PROVISIONS:
Trilogy Communications, Inc. warrants that for fifteen (15) years from the date of purchase, its AirCell® coaxial cable will not transport
water along the dielectric of the cable beyond cells damaged by external factors such as improper installation, gunshot damage or any
other damage that would compromise the integrity of the cable. In that time, if it is so deemed by Trilogy Communications, Inc. that the
fault lies in the cable due to excessive migration of water through the dielectric, then the cable will be replaced with reasonable installation
labor included. The reasonable cost of labor will be limited to an industry average, current at the time of replacement and cable replaced
must be of the same type from Trilogy Communications, Inc. The cost of replacement and installation of the cable for cells actually damaged
by external factors as described above, is not covered by these additional warranty provisions.
87
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
8 0 0 - T R I L O G Y ( 8 7 4 - 5 6 4 9 ) • 6 0 1 - 9 3 2 - 4 4 6 1 • w w w. t r i l og y c o a x . c o m
2 9 1 0 H i g h w ay 8 0 E a s t • Pe a r l , M i s s i s s i p p i 3 9 2 0 8
©2005 Trilogy Communications, Inc
Download