COOPER LIGHTING - SURE

advertisement
COOPER LIGHTING - SURE-LITES ®
DESCRIPTION
The Sure-Lites CHX Series Exits are ideal exits for general purpose
applications. An extensive range of field installed accessories, choice of
faces and the variety of possible mounting configurations permit the
tailoring of the basic exit for almost any application. Durable steel
construction, attractive styling and high efficiency illumination make this
series compatible in commercial, institutional and multi-housing
applications.
Type
Catalog #
Project
Date
Comments
Prepared by
S P E C I F I C AT I O N F E AT U R E S
E l e c t ro n i c
H o u s i n g C o n s t ru c t i o n
Wa rra n t y
- Dual Voltage Input 120/277 VAC,
60 Hz
- Line-latching
- Solid-state Voltage Limited
Charger
- Solid-state Switching
- Brownout Circuit
- Low-Voltage Disconnect
- Overload/Short Circuit Protection
- Test Switch/Power Indicator Light
- 20-gauge steel housing
- White Finish
- Universal pattern knockouts on
rear for direct mounting to
junction box
- Steel canopy (where supplied)
allows ceiling or end
mounting
- Red silk-screened lettering on
white phosphorescent, heat
tempered, impact resistant glass
lens
- Other open face lenses available consult Cooper Lighting
representative
- Lens installs from side of fixture
for more convenient, safe
maintenance
- Louvered downlight standard
- Exit: 1-year
- Battery: 5-year pro-rata,
Lead Calcium; 15-year pro-rata,
Nickel Cadmium
B a tte r y
- *Sealed Lead Calcium,
Recombination Battery
- Sealed Nickel Cadmium, (CHX7
Series Only)
- Full Recharge Time, 24 hrs. (max.)
- *Polarized Battery Terminals
- CHX Series operates DC lamps for
2 hours
- CHXH Series operates DC lamps
for 4 hours or 1.5 hours plus 24
watts remote
L a m p Da t a
- AC Incandescent: Two 20W T6 1/2
intermediate base lamps
- AC Fluorescent: Two 5W compact
fluorescent lamps
- AC LED: White LEDs
- DC: Two 6V, 3.6W DC lamps
- DC LED: White LEDs
- *Double Head units also have two
6V, 12W, DC halogen bi-pin lamps
in metal heads with die-cast
swivels
CHX/CHXH
SERIES
Code Compliance
ST E E L E X I T
- UL 924 Listed
- Life Safety NFPA 101
- NEC/OSHA
- City of Chicago Fire Code
S E L F P OW E R E D
EMERGENCY
20 04 IES SELECTION
PAT E NT S P E N D I N G
LED EXIT
C H I C AG O E X I T L I G H T I N G
ORDERING INFORMATION
Model Number
CHX3=Incandescent, Self Powered
Exit, Chicago Fire Code
CHXH3=Incandescent, High Output
Self-Powered Exit, Chicago
Fire Code
CHX5=Fluorescent, Self-Powered Exit,
Chicago Fire Code
CHXH5=Fluorescent, High Output
Self-Powered Exit, Chicago
Fire Code
CHX7=LED SELF-Powered Exit,
Chicago Fire Code
Face / Arrow Options
03=Single Face / No Arrow
Accessories
06=Single Face / Right Arrow
09=Single Face / Left Arrow
WG2=Wire Guard for use with Heads
E N E R G Y D ATA
WG10=Wire Guard for Surface Mount Only
Maximum power consumption
WGS11=Wire Guard for End or Ceiling Mount only
under all charge conditions:
12=Single Face / Double Arrow
18=Double Face / No Arrow
21=Double Face / Right or Left
Arrow
24=Double Face / Double Arrow
Heads
__=No Heads
DH=Double Heads
PK18WH=18'' Long White Pendant Kit
Charge Mode (Fully Discharged Battery)
Canopy Kit
Sealed Lead Calcium Battery
CHX1C=White Canopy Kit
Incandescent Exits
''STAIR'' Lens
Input Power:
004260SP=No Arrow
120V= 52W
004261SP=Arrow Left
277V= 52W
004262SP=Arrow Right
004263SP=Double Arrow
Fluorescent Exits
Input Power:
120V= 23W
277V= 23W
004213SP=No Arrow
LED Exits**
004214SP=Arrow Left
Input Power:
004215SP=Arrow Right
120V= 11W
Order separately.
004216SP=Double Arrow
277V= 12W
Incandescent and Fluorescent Fixtures Only.
Remote Head - 6V, 12W Single Head
C=Canopy
2
Pendant Kit
"Exit" Lens
Canopy Options
__=No Canopy
Notes: 1
1
Protective Housing
6T12MHWH=6T12MHWH - Two Maximum2
* Standby Mode (Fully Charged Battery)
Remote Head - 6V, 12W Each Double Head
Sealed Lead Calcium Battery
6T12DMHWH=6T12DMHWH - One Maximum2
Input Power consumption is reduced by
approximately 7 Watts in the standby operating
mode for incandescent and fluorescent exits.
Specifications and dimensions subject to change without notice.
Consult your representative for additional options and finishes.
ADX041894
2011-07-06 14:36:53
CHX/CHXH SERIES
P H OTO M E T R I C S
Horizontal Distribution
15
FEET
LEFT
0
FEET
RIGHT
15
Ve r t i c a l D i s t r i b u t i o n
1FC
0
10
30
20
0.5
40
50
0.3
0.2
60
70
LAMP
AXIS
80
90
0.1
100
15
FEET
LEFT
0
FEET
RIGHT
15
2FC
0
10
1FC
30
20
0.5
40
0.3
50
60
0.2
70
LAMP
AXIS
80
90
0.1
100
FEET FROM LAMP (Measured on axis)
FEET FROM LAMP (Measured on axis)
Lamp No. 29-66
Initial Lumens – 29-66 @ 302
Lamp No. 29-66
T E C H N I C A L DATA
Lamps
L i n e - L a t ch e d
S o l i d - S t a te Tra n s fe r
Self-Powered exits are offered with a choice of
two 20W T6 1/2 incandescent lamps, two 5W
F5TT compact fluorescent lamps or white LEDs.
Two 6V, 3.6W DC lamps are provided for
emergency mode operation with incandescent
and fluorescent exits. The LEDs operate in
emergency mode for LED exits. Double head
units also have two 6V, 12W DC halogen bi-pin
lamps in metal heads with die cast swivels.
Sure-Lites line-latched electronic circuitry makes
installation easy and economical. A labor
efficient AC activated load switch prevents the
lamps from turning on during installation to a
non-energized AC circuit. Line-latching
eliminates the need for a contractor's return to a
job site to connect the batteries when the
building's main power is turned on.
These exits incorporate solid-state switching
which eliminates corroded and pitted contacts
or mechanical failures associated with relays.
The switching circuit is designed to detect a loss
of AC voltage and automatically energize the
lamps. Upon restoration of AC power, the
emergency lamps will switch off and the charger
will automatically recharge the battery.
S o l i d - S t a te C h a rge r
Te s t Sw i t ch / Powe r I n d i c a to r L i g h t
Supplied with a 120/277 VAC, voltage regulated
solid-state charger. Immediately upon
restoration of AC current after a power failiure,
the charger provides a high charge rate. The
charge circuit reacts to the condition of the
battery and alters the rate of charge in order to
maintain peak battery capacity and maximize
battery life. Solid-state construction recharges
the battery following a power failure in
accordance with UL 924.
Conveniently located combination Test
Switch/Power Indicator Light allows for manual
verification of proper operation of the transfer
circuit and emergency lamps.
H o u s i n g C o n s t ru c t i o n
Exit housing is constructed of durable 20-gauge
cold rolled steel with corrosion resistant
polyester powder coat paint finish. All exits can
be mounted and wired through knockouts
located on the top and side. Surface mount back
panel has knockouts for direct mounting to
junction box. Integral louvered downlight is
standard. The mounting canopy is made of cold
rolled steel in matching finisih. Impact resistant,
heat tempered glass lens and back plate install
in channels in the exit housing to eliminate light
leaks.
Heads
All metal formed aluminum lampheads. The die
cast metal three dimensional swivel assembly
permits approximate aiming adjustment from
80° vertical and 358° rotation. The placement is
secured with a lockable pivot mounted on a
rotating base ring.
The lens provided is made of impact resistant,
heat tempered glass. Red lettering is silkscreened on a white phosphorescent
background. Full sroke arrows are provided as
specified.
The fully sealed, long-life, maintenance-free
lead calcium battery is ideal for emergency
lighting applications. These batteries typically
provide 8 to 10 years of life and may be
operated in any position.
O ve rl o a d a n d S h o rt C i rc u i t P ro te c t i o n
The solid-state overload monitoring device in
the DC circuit disconnects the lamp load from
the battery should excessive wattage demands
be made and automatically resets when the
overload or short circuit is removed. This
overload current protective feature eliminates
the need for fuses or circuit breakers for the DC
load.
B row n o u t C i rc u i t
Lens
S e a l e d L e a d C a l c i u m B a tte r y
The brownout circuit on Sure-Lites exits
monitors the flow of AC current to the exit and
activates the emergency lighting system when a
predetermined reduction of AC power occurs.
This dip in voltage will cause most ballasted
fixtures to extinguish causing loss of normal
lighting even though a total power failure has
not occurred.
S e a l e d N i cke l C a d m i u m B a tte r y
Sure-Lites sealed nickel cadmium batteries are
maintenance-free with a life expectancy of 15
years. The sealed rechargeable nickel cadmium
battery offers high discharge rates and stable
performance over a wide range of
temperatures. The specially designed resealable
vent automatically controls cell pressure,
assuring safety and reliability. This battery is
best suited for harsh ambient temperatures
because the electrolyte is not active in the
electrochemical process.
Wa rra n t y
All Sure-Lites products are backed by a firm
one-year warranty against defects in material
and workmanship (excluding lamps).
Maintenance-free, long-life, sealed lead calcium
batteries carry a five-year pro-rata warranty and
sealed nickel cadmium batteries carry a 15-year
pro-rata warranty.
Specifications and dimensions subject to change without notice.
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADX041894
2011-07-06 14:36:53
2011-07-07 11:07:23
CHX/CHXH SERIES
6 3/4"
[171mm]
4 1/2"
[114mm]
2 5/16"
[59mm]
7/8" [22mm]
4 1/2"
[114mm]
14 3/8"
[365mm]
9"
[229mm]
12 1/4"
[311mm]
6 1/2"
[165mm]
7 5/8"
[194mm]
Specifications and dimensions subject to change without notice.
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
ADX041894
2011-07-06 14:36:53
2011-07-07 11:07:23
Download