CY8CKIT-022 QUICK START GUIDE CAPSENSE® LIQUID LEVEL SENSING SHIELD Kit Contents: 1. CapSense® Liquid Level Sensing Shield board 2. CapSense Liquid Level Sensing 12 Sensor Flex PCB 3. CapSense Liquid Level Sensing 2 Sensor Flex PCB 4. Liquid container 5. Quick Start Guide 6. Micrium’s μC/Probe license card www.cypress.com/CY8CKIT-022 1 2 • Remove the adhesive sticker from the Liquid Level Sensing 12 Sensor Flex PCB • Connect the Liquid Level Sensing Shield on the CY8CKIT-042 PSoC® 4 Pioneer Kit ArduinoTM headers • Paste the Liquid Level Sensing 12 Sensor Flex PCB on the liquid container • Connect the Liquid Level Sensing 12 Sensor Flex PCB to the Liquid Level Sensing Shield board • Install the CY8CKIT-042 kit software onto your PC. Once that is done, connect the kit to your PC using the USB cable provided CY8CKIT-022 QUICK START GUIDE 3 • Download the Liquid Level Sensing code examples from the webpage www.cypress.com/CY8CKIT-022 4 • Launch PSoC Programmer from the Start menu and load the “LLS_CSD_12RX-042.hex” file • Click the Program button to program the PSoC 4 device on the CY8CKIT-042 board 5 • Launch any serial terminal program. Connect to the KitProg COM port and select baud rate as 115200 Note: If serial terminal program is not installed, then you can install Tera Term 6 • With an empty liquid container, type 'cal' and press Enter • Pour water in and out of the liquid container and observe the corresponding change in the liquid level reported in the serial terminal program 7 • Download the CY8CKIT-022 Liquid Level Sensing Shield documents and hardware design files from www.cypress.com/CY8CKIT-022 Note: This kit includes a free 30-day trial license of the Micrium µC/Probe. Refer to Kit User Guide for more details. CY8CKIT-022 QUICK START GUIDE CY8CKIT-022 CapSense Liquid Level Sensing Shield Board details UART_TX UART_RX NC NC NC GND/GND NC NC NC NC RX5/D9 RX6/D8 NC NC NC NC NC GND/GND GND/GND NC CINTA/A0 CINTB/A1 RX2/A2 RX1/A3 RX0/A4 TX0/A5 NC RX12 NC Refer flex pcb details on page 4 for pin mapping NC NC NC RX4 NC RX3 NC NC NC RX7/D7 RX8/D6 RX9/D5 RX10/D4 RX11/D3 NC UART_TX/D1 UART_RX/D0 CY8CKIT-022 QUICK START GUIDE CAPSENSE® LIQUID LEVEL SENSING SHIELD CY8CKIT-022 CapSense Liquid Level Sensing 12 Sensor Flex PCB details TX0 GND RX9 RX7 RX12 RX2 RX4 RX5 RX11 RX10 RX8 RX0 RX1 RX6 RX3 GND CY8CKIT-022 CapSense Liquid Level Sensing 2 Sensor Flex PCB details TX0 GND NC NC NC NC NC NC NC NC NC RX0 RX1 NC NC GND For latest information about this kit, visit www.cypress.com/CY8CKIT-022 © 2015 Cypress Semiconductor Corporation. All rights reserved. All trademarks or registered trademarks referenced herein are the properties of their respective owners. 002-10048 Rev.*A