Data sheet - GE Lighting

advertisement
GE
Lighting
DATA SH EE T
LED T8
tubular lamps
Product information
Features
The GE LED T8 range offers safe, reliable and affordable energy
saving alternatives to standard Fluorescent T8 lamps.
·
·
·
·
·
·
·
Available in 2’/60cm, 4’/120cm and 5’/150cm lengths, GE LED
T8s can be quickly fitted as a replacement into luminaires
operating on electro-magnetic control gear or on electronic gear
with a simple re-wire (for further details see intallation guide).
Specification Features
Energy saving up to 60% (on mains connection
versus T8 fluorescent lamps on electro-magnetic gear)
High light output up to 3000Lm
Instant-on light
Long lifetime: up to 50,000 hours L70
High Power Factor: 0.9
Wide 130° light distribution
Compatible with existing installations
Long-life and high efficiency
Application areas
• Up to 50,000 hrs rated lifetime, reduced maintenance cost
• High Efficiency, up to 111 lm/w, increased energy saving
Office
High Quality lighting effect
Hospitality
Industrial
Car Park
• High uniformity of light, create elegant lighting atmosphere
for retail & commercial applications
• Especially suitable for supermarket, high color rendering of
fresh food to engage customers
• Environment friendly - no UV, no Hg
IEC Standards
EN 55015
EN 61000-3-2
EN 61000-3-3
EN 61547
EN62493:2010
IEC 62471
IEC 60061-1
IEC 61195
IEC 60598-1
IEC 60598-2
IEC 62031
IEC 61347-2-13
Limits and methods of measurement of radio disturbance characteristics of electrical lighting
Limits for harmonic current emissions (equipment rated current <=16A)
Limitation of voltage fluctuations and flicker in low voltage supply systems (equipment rated current <=16A)
Specification for equipment for general lighting purposes. EMC Immunity requirements
Assessment of lighting equipment related to human exposure to electromagnetic field
Photo biological safety of lamps and lamp systems
Lamp Caps
IEC Based Safety Standard Requirements for Double-capped Fluorescent Lamps
Luminaires – Part 1: General requirements and tests
Luminaires – Part 2: Particular requirements (all sections)
LED modules for general lighting-Safety specifications
Particular requirements for DC or AC supplied electronic control gear for LED modules
Specification summary
Product Description
Rated
Luminous
flux (lm)
Life
B50
(hrs)
CRI
(Ra)
Energy
Efficiency
Class
Pack
Qty
(pcs)
Product
Code
LED T8 Energy saving range - G13 base
9
600
4000
6
9
600
6500
6
18
1200
4000
6
18
1200
6500
6
LED 9/T8 600MM/840/220-240V BX1/30
LED 9/T8 600MM/865/220-240V BX1/30
LED 18/T8 1200MM/840/220-240V BX1/30
LED 18/T8 1200MM/865/220-240V BX1/30
750
800
1550
1650
50 000
50 000
50 000
50 000
80
80
80
80
A+
A+
A+
A+
30
30
30
30
90450
90451
90455
90456
LED T8 High output range - G13 base
12
600
4000
6
12
600
6500
6
23
1200
4000
6
23
1200
6500
6
27
1500
4000
6
27
1500
6500
6
LED 12/T8 600MM/840/220-240V BX1/30
LED 12/T8 600MM/865/220-240V BX1/30
LED 23/T8 1200MM/840/220-240V BX1/30
LED 23/T8 1200MM/865/220-240V BX1/30
LED 27/T8 1500MM/840/220-240V BX1/20
LED 27/T8 1500MM/865/220-240V BX1/20
1050
1100
2150
2250
3000
3000
40 000
40 000
40 000
40 000
40 000
40 000
80
80
80
80
80
80
A+
A+
A+
A+
A+
A+
30
30
30
30
20
20
90453
90454
90457
90458
93010222
93010223
Rated
Wattage
Length
(mm)
CCT
(Kelvin)
CCT
Steps
Electrical and Photometric
Characteristics
Dimensions
D
A
B
C
Maximum overall length (mm)
60cm (2ft)
120cm (4ft)
150cm (5ft)
A
600
1200
1500
B
597
1207
1507
C
604
1214
1514
D
28
28
28
Weight (g)
<210
<350
<450
Nominal Voltage:
220-240V
Operating frequency:
50...60Hz
Power factor:
≥ 0,90
Ambient temperature range (9W/18W): -20°C ...+50°C
Ambient temperature range (12W/23W/27W):-20°C ...+40°C
Starting time:
< 0,5 s
Number of switching cycles:
80 000
Lumen maintenance at B50:
70%
Beam angle:
130°
Dimmable:No
Operation and Maintenance
Store and use the lamps the same way as standard fluorescent lamps.
•Lamps should be kept free from contamination.
•Switch off mains supply before installing/removing lamp.
•Good condition of the lamp-holder contacts is important to ensure proper operation of lamp.
•For magnetic gear system ensure existing fluorescent starter is replaced with LED T8 starter (included in each pack)
•For direct wire please check the provided installation instructions
•Use in fully enclosed fixtures may affect life performance.
•Not for use in emergency lighting circuits
Spectral power distribution
Daylight - 6500K
80
Spectral Power intensity (mW/nm)
40
35
30
25
20
15
10
5
0
70
60
50
40
30
20
10
Wavelength (nm)
380
400
420
440
460
480
500
520
540
560
580
600
620
640
660
680
700
720
740
760
780
0
380
400
420
440
460
480
500
520
540
560
580
600
620
640
660
680
700
720
740
760
780
Spectral Power intensity (mW/nm)
Cool white - 4000K
45
Wavelength (nm)
Photometric and Lumen Maintenance tests conducted as defined by IES LM-79-08 and IES LM-80-08 Approved Methods.
www.gelighting.com
and General Electric are both registered trademarks
of the General Electric Company
GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a
general guide, and we may change specifications time to time in the interest of product development, without prior notification or public
announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part
of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability
arising from the reliance on such data to the extent permitted by law.
LED T8 Data Sheet - October 2014