GE Lighting DATA SH EE T LED T8 tubular lamps Product information Features The GE LED T8 range offers safe, reliable and affordable energy saving alternatives to standard Fluorescent T8 lamps. · · · · · · · Available in 2’/60cm, 4’/120cm and 5’/150cm lengths, GE LED T8s can be quickly fitted as a replacement into luminaires operating on electro-magnetic control gear or on electronic gear with a simple re-wire (for further details see intallation guide). Specification Features Energy saving up to 60% (on mains connection versus T8 fluorescent lamps on electro-magnetic gear) High light output up to 3000Lm Instant-on light Long lifetime: up to 50,000 hours L70 High Power Factor: 0.9 Wide 130° light distribution Compatible with existing installations Long-life and high efficiency Application areas • Up to 50,000 hrs rated lifetime, reduced maintenance cost • High Efficiency, up to 111 lm/w, increased energy saving Office High Quality lighting effect Hospitality Industrial Car Park • High uniformity of light, create elegant lighting atmosphere for retail & commercial applications • Especially suitable for supermarket, high color rendering of fresh food to engage customers • Environment friendly - no UV, no Hg IEC Standards EN 55015 EN 61000-3-2 EN 61000-3-3 EN 61547 EN62493:2010 IEC 62471 IEC 60061-1 IEC 61195 IEC 60598-1 IEC 60598-2 IEC 62031 IEC 61347-2-13 Limits and methods of measurement of radio disturbance characteristics of electrical lighting Limits for harmonic current emissions (equipment rated current <=16A) Limitation of voltage fluctuations and flicker in low voltage supply systems (equipment rated current <=16A) Specification for equipment for general lighting purposes. EMC Immunity requirements Assessment of lighting equipment related to human exposure to electromagnetic field Photo biological safety of lamps and lamp systems Lamp Caps IEC Based Safety Standard Requirements for Double-capped Fluorescent Lamps Luminaires – Part 1: General requirements and tests Luminaires – Part 2: Particular requirements (all sections) LED modules for general lighting-Safety specifications Particular requirements for DC or AC supplied electronic control gear for LED modules Specification summary Product Description Rated Luminous flux (lm) Life B50 (hrs) CRI (Ra) Energy Efficiency Class Pack Qty (pcs) Product Code LED T8 Energy saving range - G13 base 9 600 4000 6 9 600 6500 6 18 1200 4000 6 18 1200 6500 6 LED 9/T8 600MM/840/220-240V BX1/30 LED 9/T8 600MM/865/220-240V BX1/30 LED 18/T8 1200MM/840/220-240V BX1/30 LED 18/T8 1200MM/865/220-240V BX1/30 750 800 1550 1650 50 000 50 000 50 000 50 000 80 80 80 80 A+ A+ A+ A+ 30 30 30 30 90450 90451 90455 90456 LED T8 High output range - G13 base 12 600 4000 6 12 600 6500 6 23 1200 4000 6 23 1200 6500 6 27 1500 4000 6 27 1500 6500 6 LED 12/T8 600MM/840/220-240V BX1/30 LED 12/T8 600MM/865/220-240V BX1/30 LED 23/T8 1200MM/840/220-240V BX1/30 LED 23/T8 1200MM/865/220-240V BX1/30 LED 27/T8 1500MM/840/220-240V BX1/20 LED 27/T8 1500MM/865/220-240V BX1/20 1050 1100 2150 2250 3000 3000 40 000 40 000 40 000 40 000 40 000 40 000 80 80 80 80 80 80 A+ A+ A+ A+ A+ A+ 30 30 30 30 20 20 90453 90454 90457 90458 93010222 93010223 Rated Wattage Length (mm) CCT (Kelvin) CCT Steps Electrical and Photometric Characteristics Dimensions D A B C Maximum overall length (mm) 60cm (2ft) 120cm (4ft) 150cm (5ft) A 600 1200 1500 B 597 1207 1507 C 604 1214 1514 D 28 28 28 Weight (g) <210 <350 <450 Nominal Voltage: 220-240V Operating frequency: 50...60Hz Power factor: ≥ 0,90 Ambient temperature range (9W/18W): -20°C ...+50°C Ambient temperature range (12W/23W/27W):-20°C ...+40°C Starting time: < 0,5 s Number of switching cycles: 80 000 Lumen maintenance at B50: 70% Beam angle: 130° Dimmable:No Operation and Maintenance Store and use the lamps the same way as standard fluorescent lamps. •Lamps should be kept free from contamination. •Switch off mains supply before installing/removing lamp. •Good condition of the lamp-holder contacts is important to ensure proper operation of lamp. •For magnetic gear system ensure existing fluorescent starter is replaced with LED T8 starter (included in each pack) •For direct wire please check the provided installation instructions •Use in fully enclosed fixtures may affect life performance. •Not for use in emergency lighting circuits Spectral power distribution Daylight - 6500K 80 Spectral Power intensity (mW/nm) 40 35 30 25 20 15 10 5 0 70 60 50 40 30 20 10 Wavelength (nm) 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 0 380 400 420 440 460 480 500 520 540 560 580 600 620 640 660 680 700 720 740 760 780 Spectral Power intensity (mW/nm) Cool white - 4000K 45 Wavelength (nm) Photometric and Lumen Maintenance tests conducted as defined by IES LM-79-08 and IES LM-80-08 Approved Methods. www.gelighting.com and General Electric are both registered trademarks of the General Electric Company GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a general guide, and we may change specifications time to time in the interest of product development, without prior notification or public announcement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising from the reliance on such data to the extent permitted by law. LED T8 Data Sheet - October 2014