® Frost Fighter Clear View II Defrosters Defrosters and defroster controls made easy www.frostfighter.com 24V Master Defroster Catalog 24 Volt 24 VOLT World leader in aftermarket defrosters and control solutions in 12 and 24 volt. Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2013 Planned Products LLC www.frostfighter.com Page 1 of 78 ® Frost Fighter Clear View II Defrosters made easy www.frostfighter.com Clear View II Defrosters Frost Fighter® Clear View II Defrosters match the heating performance of factory installed rear window defrosters, clearing snow and ice in minutes. Cost effective and easy to install, new Clear View II defrosters provide full window coverage with an attractive factory appearance. Compatible with vehicles from cars and trucks to snow moving equipment, tractors and heavy equipment, Clear View makes adding a defroster easy. Use anyplace widow defrosting is needed. How they work Clear View defrosters have an electrical resistance which when powered provides the heat needed to clear windows of snow and ice in minutes. Heating is accomplished through contact between the defroster elements and the window. The defroster is connected electrically through the buss bar tabs and activated with the automatic ThermaSync defroster control. Easy Application The heating elements come on prespaced rolls for easy and accurate application. Heating elements bond directly to the window and are trimmed for a custom defroster fit. Once the heating elements are bonded to the window the side buss bars are placed and a black plastic cover applied for a finished factory appearance. Connections The side buss bars include integral tabs positioned for easy connection to ThermaSync® defroster controls or to existing defroster wiring. Clear View II defrosters are available individually or with a full wiring harness, control and installation kit. Finished Appearance Heating elements match the brownish color of factory defrosters and adhere directly to the glass for improved visibility and safe winter driving. No backing is left on the window to crack or yellow. NEW Performance and Sizes Clear View II Defrosters feature enhanced bonding, new controls and proven heating capability to defrost windows even in the most challenging winter conditions. Now available in hundreds of sizes in 12 and 24 volt Clear View II defrosters now fit almost any window. Clear View II make defrosters EASY! Fully illustrated instructions come with every kit. 24 Volt Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2013 Planned Products LLC Infrared image showing a Clear View II Defroster. Right side on. www.frostfighter.com Page 2 of 78 ® Frost Fighter ThermaSync Defroster controls with smarts www.frostfighter.com ThermaSync Defroster Controls New Frost Fighter ThermaSync® defroster controls are the perfect companion for Clear View II and other defrosters. Available in four models from the simple automatic ten minute timing to more sophisticated adjustable automatic shut off timing, power modulation and network control allowing a single switch to control multiple defrosters. ThermaSync Defroster Control and Switch. With the addition of a Switch Boss, 2812/2824 ThermaSync controls can activate several defrosters at once through a single switch making the system ideal for multiple defroster installations like industrial equipment cabs. Power Modulation ThermaSync controls can modulate the apparent power to the defroster from 3% up to 100%. This feature enables hundreds of new Clear View II defroster sizes to fit almost any window in 12 and 24 volt. ThermaSync Automatic Timing Press the defroster symbol on the remote switch to turn the defroster on. The defroster stays on until the switch is pressed again or the ThermaSync control times out. The control can be set to time out from 10 to 160 minutes or can be left on indefinitely depending on the internal jumper settings. This feature is good for applications where longer timing cycles are desired like snow plow equipment. 24 Volt One Switch, Multiple Defrosters A single switch can activate many defrosters using the ThermaSync Switch Boss. This network control is good for applications that require several defrosters to be activated from a single switch. Switch Boss defroster network control. One switch controls many defrosters. Mounting The ThermaSync control can be secured out of sight under the dash while the switch can be mounted remotely in dash. A separate under dash mount is included with full kits. Installation Options Clear View II Defrosters and ThermaSync Controls are available individually or with a full installation package including a wire harness, fuse, fuse holder, switch mounting plate, power tap, wire ties, surface cleaner/adhesion promoter and full instructions. Complete defroster. Representative photo only. Clear View II defrosters and ThermaSync controls are available for 12 and 24 volt systems. See our website for all Clear View II defrosters and ThermaSync Controls. Click here to view our online catalog. Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2013 Planned Products LLC www.frostfighter.com Page 3 of 78 ® Frost Fighter Clear View II Ordering and Tips www.frostfighter.com How to order To order Clear View II Defrosters follow the steps below. Determine Defrost Area Take a good look at the window to establish the defrost area. The elements do not need to completely fill the area to be effective. While Clear View II defrosters are easy to install there are a few things that are critical to success! All units come with full instructions. 1. Select a defroster that fits in the window. Respect the minimum and maximum allowed widths. Allow at least 1.5 in (3.8 cm) clearance from the windows edge. On vehicles with tightly curving windows the defroster should stop before the radius. Take back up lights into account. 2. Do NOT add or remove heating elements from Clear View II Defrosters. Important! The defroster height (top-to-bottom) is fixed by the number of grid lines and cannot be changed. The defroster width (side-to-side) can be trimmed within the minimum and maximum defroster sizes. Select the Clear View Defroster 3. Follow the layout in the instructions regarding the number of heating elements per buss bar section. 4. Make sure surface is CLEAN. Clean with window cleaner and then use the GAP-1 wipe included with each kit. Order stock Clear View Defrosters online. Frost Fighter Catalog. Start by selecting a defroster that fits the height (top-to-bottom) of the window. Then select the defroster width (side-to-side) between the maximum and minimum width for the defroster. 24 Volt If replacing an existing defroster or when NOT using the ThermaSync defroster control – only defrosters with 100% power modulation MUST be used. Only ThermaSync has power modulation. Secrets to Defroster Success Measure the Defrost Area The height listed includes the tab ends which are 5/8 in (1.6 cm). Important! Planned Products LLC 4699 Nautilus Court S. Suite 201 Boulder, CO 80301 USA Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2013 Planned Products LLC Tel: 303.682.0274 Fax: 303.682.0678 info1@frostfighter.com www.frostfighter.com www.frostfighter.com Page 4 of 78 ® Frost Fighter Clear View II Technical www.frostfighter.com Peak Current This is the current that is obtained by dividing the Voltage at the heater by the Resistance of the heater. It is important that the 25 ampere rating of the electronic switch not be exceeded. It is also important in calculating the voltage drop in the circuit feeding the heaters, and is independent of duty cycle. RMS Current This is the current that actually does the heating. It is obtained by multiplying the Peak Current times the square root of the duty cycle. To obtain adequate heat on the window, the RMS current needs to be at least 2.75 amperes in all conductors, and to prevent over heating the window, cannot be greater than 4.3 amperes in any conductor. Average Current This current represents the amount of drain on the battery. It is obtained by multiplying the Peak Current times the duty cycle. If the window is warmed for ten minutes without the engine running, the ampere-hour drain on the battery, the battery drain will never exceed a comfortable 4.2Ah. Fuse Ratings Since fuses are sensitive to RMS current, recommended fuse ratings should be at least 20% higher that the RMS current. Standard automotive fuse ratings are 5.0A, 7.5A, 10A, 15A, 20A, 25A and 30A. So the recommended fuse rating is obtained by multiplying the maximum RMS current times 1.2 and selecting the next higher standard fuse. Duty Cycle Duty Cycle is defined as the time that the heater is ON divided by the time the heater is OFF plus the time the heater is ON, and is generally express in percent. If the heater is ON all the time, the duty cycle is said to be 100%. Part Numbers Clear View defrosters have a simple part numbering set up. 1204 - 2031 - L - STK Stick Kit Defroster (if available) Tab Position (all tabs on left) ThermaSync Defroster Controls The 2712/2724 ThermaSync defroster controls provide simple automatic timing while the 2812/2824 controls allow for selectable automatic shut off timing in 10, 20, 40, 80, 160 minutes or manual operation. See page 10 for more. 24 Volt Minimum and Maximum Length Defroster Elements Voltage Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2013 Planned Products LLC www.frostfighter.com Page 5 of 78 Clear View II Defrosters – 24 Volt Full Defroster Part Number 1 Stick Kit Part Number Height inch (cm) Length, inch (cm) Start here, select height Min Max Heating Elements Grid Format Power Tabs Modulation 2 Voltage Peak Current 3 (Amp) Short Long Fuse (Amp) Drawing? Stick Kit Price Full Kit Price 2402-2835-L 4.12 (10.4) 4 28 (71) 35 (89) 2 2 Ser 1Par 3% L 24 25.0 19.4 5 Yes $63.95 2402-3450-L 4.12 (10.4) 4 34 (86) 50 (127) 2 2 Ser 1Par 6% L 24 20.4 13.8 7.5 Yes $64.40 2402-4871-L 4.12 (10.4) 4 48 (122) 71 (180) 2 2 Ser 1Par 12% L 24 14.4 9.7 7.5 Yes $64.85 2402-6884-L 4.12 (10.4) 4 68 (173) 84 (213) 2 2 Ser 1Par 25% L 24 10.2 8.2 7.5 Yes $65.30 2403-1824 3.75 (9.5) 18 (46) 24 (61) 3 3 Ser 1Par 3% L/R 24 25.0 19.4 5.0 Yes $65.75 2403-2333 3.75 (9.5) 23 (58) 33 (84) 3 3 Ser 1Par 6% L/R 24 20.4 13.8 7.5 Yes $66.20 2403-3247 3.75 (9.5) 32 (81) 47 (119) 3 3 Ser 1Par 12% L/R 24 14.4 9.7 7.5 Yes $66.65 2403-4567 3.75 (9.5) 45 (114) 67 (170) 3 3 Ser 1Par 25% L/R 24 10.2 6.9 7.5 Yes $67.10 2403-6484 3.75 (9.5) 64 (163) 84 (213) 3 3 Ser 1Par 50% L/R 24 7.2 5.5 7.5 Yes $67.55 2404-1418-L 5.00 (12.7) 14 (36) 18 (46) 4 4 Ser 1Par 3% L 24 25.0 19.4 5.0 Yes $68.00 2404-1725-L 5.00 (12.7) 17 (43) 25 (64) 4 4 Ser 1Par 6% L 24 20.4 13.8 7.5 Yes $68.45 2404-2435-L 5.00 (12.7) 24 (61) 35 (89) 4 4 Ser 1Par 12% L 24 14.4 9.7 7.5 Yes $68.90 2404-3450-L 5.00 (12.7) 34 (86) 50 (127) 4 4 Ser 1Par 25% L 24 10.2 6.9 7.5 Yes $69.35 2404-4871-L 5.00 (12.7) 48 (122) 71 (180) 4 4 Ser 1Par 50% L 24 7.2 4.9 7.5 Yes $69.80 5.00 (12.7) 68 (173) 84 (213) 4 4 Ser 1Par 100% L 24 5.1 4.1 7.5 Yes 2404-5571-L 5.00 (12.7) 55 (140) 71 (180) 4 2 Ser 2Par 12% L 24 25.0 19.4 10.0 Yes $70.70 2404-6884-L1 5.00 (12.7) 68 (172) 84 (213) 4 2 Ser 2Par 25% L 24 20.4 16.4 15.0 Yes $71.15 2405-1114 6.25 (15.8) 11 (28) 14 (36) 5 5 Ser 1Par 3% L/R 24 25.0 19.4 5.0 Yes $71.60 2405-1420 6.25 (15.8) 14 (36) 20 (51) 5 5 Ser 1Par 6% L/R 24 20.4 13.8 7.5 Yes $72.05 2405-1928 6.25 (15.8) 19 (48) 28 (71) 5 5 Ser 1Par 12% L/R 24 14.4 9.7 7.5 Yes $72.50 2405-2740 6.25 (15.8) 27 (69) 40 (102) 5 5 Ser 1Par 25% L/R 24 10.2 6.9 7.5 Yes $72.95 2405-3857 6.25 (15.8) 38 (97) 57 (145) 5 5 Ser 1Par 50% L/R 24 7.2 4.9 7.5 Yes $73.40 54 (137) 80 (203) 5 5 Ser 1Par 100% L/R 24 5.1 3.4 7.5 Yes 2404-6884-L 2405-5480 24 Volt 2404-6884-L-STK 2405-5480-STK 6.25 (15.8) Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com $35.25 $38.85 $70.25 $73.85 Page 6 of 78 Full Defroster Part Number 1 Stick Kit Part Number Height inch (cm) Start here, select height Length, inch (cm) Min Max Heating Elements Grid Format Power Tabs Modulation 2 Voltage Peak Current 3 (Amp) Short Long Fuse (Amp) Drawing? Stick Kit Price Full Kit Price 2406-0912-L 7.50 (19.0) 9 (23) 12 (30) 6 6 Ser 1Par 3% L 24 25.0 19.4 5.0 Yes $74.30 2406-1117-L 7.50 (19.0) 11 (28) 17 (43) 6 6 Ser 1Par 6% L 24 20.4 13.8 7.5 Yes $74.75 2406-1624-L 7.50 (19.0) 16 (41) 24 (61) 6 6 Ser 1Par 12% L 24 14.4 9.7 7.5 Yes $75.20 2406-2333-L 7.50 (19.0) 23 (58) 33 (84) 6 6 Ser 1Par 25% L 24 10.2 6.9 7.5 Yes $75.65 2406-3247-L 7.50 (19.0) 32 (81) 47 (119) 6 6 Ser 1Par 50% L 24 7.2 4.9 7.5 Yes $76.10 7.50 (19.0) 45 (114) 67 (170) 6 6 Ser 1Par 100% L 24 5.1 3.4 7.5 Yes 2406-3747 7.50 (19.0) 37 (94) 47 (119) 6 3 Ser 2Par 12% L/R 24 25.0 19.4 10.0 Yes $77.00 2406-4567 7.50 (19.0) 45 (114) 67 (170) 6 3 Ser 2Par 25% L/R 24 20.4 13.8 15.0 Yes $77.45 2406-6484 7.50 (19.0) 64 (163) 84 (213) 6 3 Ser 2Par 50% L/R 24 14.4 10.9 15.0 Yes $77.90 2407-0810 8.75 (22.2) 08 (20) 10 (25) 7 7 Ser 1Par 3% L/R 24 24.6 19.4 5.0 Yes $78.35 2407-1014 8.75 (22.2) 10 (25) 14 (36) 7 7 Ser 1Par 6% L/R 24 20.4 13.8 7.5 Yes $78.80 2407-1420 8.75 (22.2) 14 (36) 20 (51) 7 7 Ser 1Par 12% L/R 24 14.4 9.7 7.5 Yes $79.25 2407-1929 8.75 (22.2) 19 (48) 29 (74) 7 7 Ser 1Par 25% L/R 24 10.2 6.9 7.5 Yes $79.70 2407-2740 8.75 (22.2) 27 (69) 40 (102) 7 7 Ser 1Par 50% L/R 24 7.2 4.9 7.5 Yes $80.15 8.75 (22.2) 39 (99) 57 (145) 7 7 Ser 1Par 100% L/R 24 5.1 3.4 7.5 Yes 2406-4567-L 2407-3957 2406-4567-L-STK 2407-3957-STK $41.55 $45.60 $76.55 $80.60 2408-0913-L 10.00 (25.4) 09 (23) 13 (33) 8 8 Ser 1Par 6% L 24 19.1 13.8 5.0 Yes $81.05 2408-1218-L 10.00 (25.4) 12 (30) 18 (46) 8 8 Ser 1Par 12% L 24 14.4 9.7 7.5 Yes $81.50 2408-1725-L 10.00 (25.4) 17 (43) 25 (64) 8 8 Ser 1Par 25% L 24 10.2 6.9 7.5 Yes $81.95 2408-2435-L 10.00 (25.4) 24 (61) 35 (89) 8 8 Ser 1Par 50% L 24 7.2 4.9 7.5 Yes $82.40 50 (127) 8 8 Ser 1Par 100% L 24 5.1 3.4 7.5 Yes 2408-3450-L1 2408-3450-L1-STK 10.00 (25.4) 34 (86) $47.85 $82.85 2408-2835-L 10.00 (25.4) 28 (71) 35 (89) 8 4 Ser 2Par 12% L 24 25.0 19.4 10.0 Yes $83.30 2408-3450-L 10.00 (25.4) 34 (86) 50 (127) 8 4 Ser 2Par 25% L 24 20.4 13.8 15.0 Yes $83.75 2408-4871-L 10.00 (25.4) 48 (122) 71 (180) 8 4 Ser 2Par 50% L 24 14.4 9.7 15.0 Yes $84.20 10.00 (25.4) 68 (173) 84 (213) 8 4 Ser 2Par 100% L 24 10.2 8.2 15.0 Yes 11.25 (28.6) 11 (28) 16 (41) 9 9 Ser 1Par 12% L/R 24 14.4 9.7 7.5 Yes 2408-6884-L 2409-1116 24 Volt 2408-6884-L-STK Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com $49.65 $84.65 $85.10 Page 7 of 78 1 Full Defroster Stick Kit Part Number Part Number Height inch (cm) Start here, select height Length, inch (cm) Min Heating Elements Grid Format Power Tabs Modulation 2 Voltage Max Peak Current 3 (Amp) Short Long Fuse (Amp) Drawing? Stick Kit Price Full Kit Price 2409-1522 11.25 (28.6) 15 (38) 22 (56) 9 9 Ser 1Par 25% L/R 24 10.2 6.9 7.5 Yes $85.55 2409-2131 11.25 (28.6) 21 (53) 31 (79) 9 9 Ser 1Par 50% L/R 24 7.2 4.9 7.5 Yes $86.00 11.25 (28.6) 30 (76) 44 (112) 9 9 Ser 1Par 100% L/R 24 5.1 3.4 7.5 Yes 2409-5567 11.25 (28.6) 55 (140) 67 (170) 9 3 Ser 3Par 25% L/R 24 25.0 20.6 15.0 Yes $86.90 2409-6484 11.25 (28.6) 64 (163) 84 (213) 9 3 Ser 3Par 50% L/R 24 21.6 16.4 20.0 Yes $87.35 2410-1420-L 12.50 (31.9) 14 (36) 20 (51) 10 10 Ser 1Par 25% L 24 10.2 6.9 7.5 Yes $87.80 2410-1928-L 12.50 (31.9) 19 (48) 28 (71) 10 10 Ser 1Par 50% L 24 7.2 4.9 7.5 Yes $88.25 12.50 (31.9) 27 (69) 40 (102) 10 10 Ser 1Par 100% L 24 5.1 3.4 7.5 Yes 2410-2228 12.50 (31.9) 22 (56) 28 (71) 10 5 Ser 2Par 12% L/R 24 25.0 19.4 10.0 Yes $89.15 2410-2740 12.50 (31.9) 27 (69) 40 (102) 10 5 Ser 2Par 25% L/R 24 20.4 13.8 15.0 Yes $89.60 2410-3857 12.50 (31.9) 38 (97) 57 (145) 10 5 Ser 2Par 50% L/R 24 14.4 9.7 15.0 Yes $90.05 12.50 (31.9) 54 (137) 80 (203) 10 5 Ser 2Par 100% L/R 24 10.2 6.9 15.0 Yes 2411-1218 13.75 (34.9) 12 (30) 18 (46) 11 11 Ser 1Par 25% L/R 24 10.2 6.9 7.5 Yes $90.95 2411-1726 13.75 (34.9) 17 (43) 26 (66) 11 11 Ser 1Par 50% L/R 24 7.2 4.9 7.5 Yes $91.40 13.75 (34.9) 25 (64) 36 (91) 11 11 Ser 1Par 100% L/R 24 5.1 3.4 7.5 Yes 2412-0812-L 15.00 (38.1) 08 (20) 12 (30) 12 1 Ser 12Par 12% L 24 14.4 9.7 7.5 Yes $92.30 2412-1117-L 15.00 (38.1) 11 (28) 17 (43) 12 1 Ser 12Par 25% L 24 10.2 6.9 7.5 Yes $92.75 2412-1624-L 15.00 (38.1) 16 (41) 24 (61) 12 12 Ser 1Par 50% L 24 7.2 4.9 7.5 Yes $93.20 15.00 (38.1) 23 (58) 33 (84) 12 12 Ser 1Par 100% L 24 5.1 3.4 7.5 Yes 2412-1824-L 15.00 (38.1) 18 (46) 24 (61) 12 6 Ser 2Par 12% L 24 25.0 19.4 10.0 Yes $94.10 2412-2333-L 15.00 (38.1) 23 (58) 33 (84) 12 6 Ser 2Par 25% L 24 20.4 13.8 15.0 Yes $94.55 2412-3247-L 15.00 (38.1) 32 (81) 47 (119) 12 6 Ser 2Par 50% L 24 14.4 9.7 15.0 Yes $95.00 15.00 (38.1) 45 (114) 67 (170) 12 6 Ser 2Par 100% L 24 10.2 6.9 15.0 Yes 2412-4150-L 15.00 (38.1) 41 (105) 50 (127) 12 4 Ser 3Par 25% L 24 25.0 20.6 15.0 Yes $95.90 2412-4871-L 15.00 (38.1) 48 (122) 71 (180) 12 4 Ser 3Par 50% L 24 21.6 14.6 20.0 Yes $96.35 2409-3044 2410-2740-L 2410-5480 2411-2536 2412-2333-L1 2412-4567-L 24 Volt 2409-3044-STK 2410-2740-L-STK 2410-5480-STK 2411-2536-STK 2412-2333-L1-STK 2412-4567-L-STK Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com $51.45 $53.70 $55.50 $56.85 $58.65 $60.45 $86.45 $88.70 $90.50 $91.85 $93.65 $95.45 Page 8 of 78 Full Defroster Part Number 1 Stick Kit Part Number Height inch (cm) Start here, select height 2412-6884-L 2412-6884-L-STK Length, inch (cm) Min Heating Elements Grid Format Power Tabs Modulation 2 Voltage Max Peak Current 3 (Amp) Short Long Fuse (Amp) Drawing? Stick Kit Price 15.00 (38.1) 68 (173) 84 (213) 12 4 Ser 3Par 100% L 24 15.3 12.3 20.0 Yes 2413-0711 16.25 (41.3) 07 (18) 11 (28) 13 1 Ser 13Par 12% L/R 24 14.4 9.7 7.5 Yes $97.25 2413-1015 16.25 (41.3) 10 (25) 15 (38) 13 1 Ser 13Par 25% L/R 24 10.2 6.9 7.5 Yes $97.70 2413-1522 16.25 (41.3) 15 (38) 22 (56) 13 13 Ser 1Par 50% L/R 24 7.2 4.9 7.5 Yes $98.15 16.25 (41.3) 21 (53) 31 (79) 13 13 Ser 1Par 100% L/R 24 5.1 3.4 7.5 Yes 2414-1014-L 17.50 (44.5) 10 (25) 14 (36) 14 1 Ser 14Par 25% L 24 10.2 6.9 7.5 Yes $99.05 2414-1420-L 17.50 (44.5) 14 (36) 20 (51) 14 1 Ser 14Par 50% L 24 7.2 4.9 7.5 Yes $99.50 17.50 (44.4) 19 (48) 29 (74) 14 14 Ser 1Par 100% L 24 5.1 3.4 7.5 Yes 2414-1620 17.50 (44.4) 16 (41) 20 (51) 14 7 Ser 2Par 12% L/R 24 25.0 19.4 10.0 Yes $100.40 2414-1929 17.50 (44.4) 19 (48) 29 (74) 14 7 Ser 2Par 25% L/R 24 20.4 13.8 15.0 Yes $100.85 2414-2740 17.50 (44.4) 27 (69) 40 (102) 14 7 Ser 2Par 50% L/R 24 14.4 9.7 15.0 Yes $101.30 17.50 (44.4) 39 (99) 57 (145) 14 7 Ser 2Par 100% L/R 24 10.2 6.9 15.0 Yes 2415-0913 18.75 (47.6) 09 (23) 13 (33) 15 1 Ser 15Par 25% L/R 24 10.2 6.9 7.5 Yes $102.20 2415-1319 18.75 (47.6) 13 (33) 19 (48) 15 1 Ser 15Par 50% L/R 24 7.2 4.9 7.5 Yes $102.65 18.75 (47.6) 18 (46) 27 (69) 15 15 Ser 1Par 100% L/R 24 5.1 3.4 7.5 Yes 2415-3340 18.75 (47.6) 33 (84) 40 (102) 15 5 Ser 3Par 25% L/R 24 25.0 20.6 15.0 Yes $103.55 2415-3857 18.75 (47.6) 38 (97) 57 (145) 15 5 Ser 3Par 50% L/R 24 21.6 14.6 20.0 Yes $104.00 18.75 (47.6) 54 (137) 80 (203) 15 5 Ser 3Par 100% L/R 24 15.3 10.3 20.0 Yes 2416-0813-L 20.00 (50.8) 08 (20) 13 (33) 16 1 Ser 16Par 25% L 24 10.2 6.9 7.5 Yes $104.90 2416-1218-L 20.00 (50.8) 12 (30) 18 (46) 16 1 Ser 16Par 50% L 24 7.2 4.9 7.5 Yes $105.35 25 (64) 16 16 Ser 1Par 100% L 24 5.0 3.4 5.0 Yes 28 (71) 16 2 Ser 8Par 12% L 24 25.0 19.4 10.0 Yes 2413-2131 2414-1929-L 2414-3957 2415-1827 2415-5480 2416-1725-L1 2416-1418-L 24 Volt 2413-2131-STK 2414-1929-L-STK 2414-3957-STK 2415-1827-STK 2415-5480-STK 2416-1725-L1-STK 20.00 (50.8) 17 (43) 20.00 (50.8) 14 (36) Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com $61.80 Full Kit Price $63.60 $64.95 $66.75 $68.10 $69.45 $70.80 $96.80 $98.60 $99.95 $101.75 $103.10 $104.45 $105.80 $106.25 Page 9 of 78 Full Defroster Part Number 1 Stick Kit Part Number Height inch (cm) Start here, select height Length, inch (cm) Heating Elements Min Max 17 (43) 25 (64) 16 20.00 (50.8) 24 (61) 35 (89) 16 20.00 (50.8) 34 (86) 50 (127) 20.00 (50.8) 55 (140) 20.00 (50.8) Grid Format 2 Voltage Peak Current 3 (Amp) Short Long Fuse (Amp) Drawing? Stick Kit Price Full Kit Price 10.0 Yes $106.70 9.7 15.0 Yes $107.15 10.2 6.9 15.0 Yes 24 25.0 19.4 20.0 Yes L 24 20.4 16.4 25.0 Yes 25% L/R 24 10.2 6.9 7.5 Yes $108.95 1 Ser 17Par 50% L/R 24 7.2 4.9 7.5 Yes $109.40 17 1 Ser 17Par 100% L/R 24 5.1 3.4 7.5 Yes 11 (28) 18 1 Ser 18Par 25% L 24 10.2 6.9 7.5 Yes $110.30 11 (28) 16 (41) 18 1 Ser 18Par 50% L 24 7.2 4.9 7.5 Yes $110.75 2418-1522-L1-STK 22.50 (57.2) 15 (38) 22 (55) 18 1 Ser 18Par 100% L 24 5.1 3.4 7.5 Yes 2418-1216 22.50 (57.2) 12 (30) 16 (41) 18 2 Ser 9Par 12% L/R 24 25.0 19.4 10.0 Yes $111.65 2418-1522 22.50 (57.2) 15 (38) 22 (56) 18 2 Ser 9Par 25% L/R 24 20.4 13.8 15.0 Yes $112.10 2418-2131 22.50 (57.1) 21 (53) 31 (79) 18 9 Ser 2Par 50% L/R 24 14.4 9.7 15.0 Yes $112.55 22.50 (57.1) 30 (76) 44 (112) 18 9 Ser 2Par 100% L/R 24 10.2 6.9 15.0 Yes 2418-2833-L 22.50 (57.1) 28 (71) 33 (84) 18 6 Ser 3Par 25% L 24 25.0 20.6 15.0 Yes $113.45 2418-3247-L 22.50 (57.1) 32 (81) 47 (119) 18 6 Ser 3Par 50% L 24 21.6 14.6 20.0 Yes $113.90 22.50 (57.1) 45 (114) 67 (170) 18 6 Ser 3Par 100% L 24 15.3 10.3 20.0 Yes 23.75 (60.3) 10 (25) 15 (38) 19 1 Ser 19Par 50% L/R 24 7.2 4.9 7.5 Yes 23.75 (60.3) 14 (36) 21 (53) 19 1 Ser 19Par 100% L/R 24 5.1 3.4 7.5 Yes 25.00 (63.5) 10 (25) 14 (36) 20 1 Ser 20Par 50% L 24 7.2 4.9 7.5 Yes 2420-1420-L1-STK 25.00 (63.5) 14 (36) 20 (51) 20 1 Ser 20Par 100% L 24 5.1 3.4 7.5 Yes 2420-1114-L 25.00 (63.5) 11 (28) 14 (36) 20 2 Ser 10Par 12% L 24 25.0 19.4 10.0 Yes $116.60 2420-1420-L 25.00 (63.5) 14 (36) 20 (51) 20 2 Ser 10Par 25% L 24 20.4 13.8 15.0 Yes $117.05 2420-1928-L 25.00 (63.5) 19 (48) 28 (71) 20 2 Ser 10Par 50% L 24 14.4 9.7 15.0 Yes $117.50 2416-1725-L 8 Ser 2Par Power Tabs Modulation 25% L 24 19.9 13.8 8 Ser 2Par 50% L 24 14.4 16 8 Ser 2Par 100% L 24 71 (180) 16 4 Ser 4Par 50% L 20.00 (50.8) 68 (173) 84 213) 16 4 Ser 4Par 100% 2417-0812 21.25 (53.9) 08 (20) 12 (30) 17 1 Ser 17Par 2417-1117 21.25 (53.9) 11 (28) 17 (43) 17 21.25 (53.9) 16 (41) 24 (61) 2418-0811-L 22.50 (57.2) 08 (20) 2418-1116-L 22.50 (57.2) 2416-2435-L 2416-3450-L 2416-3450-L-STK 2416-5571-L 2416-6884-L 2417-1624 2418-1522-L1 2418-3044 2418-4567-L 2416-6884-L-STK 2417-1624-STK 2418-3044-STK 2418-4567-L-STK 2419-1015 2419-1421 2420-1014-L 2420-1420-L1 24 Volt 2419-1421-STK Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com $72.60 $107.60 $108.05 $73.50 $74.85 $76.20 $78.00 $79.35 $108.50 $109.85 $111.20 $113.00 $114.35 $114.80 $80.25 $115.25 $115.70 $81.15 $116.15 Page 10 of 78 Full Defroster Part Number 1 Stick Kit Part Number Height inch (cm) Start here, select height 2420-2740-L 2420-2740-L-STK 2420-4457 2420-5480 2420-5480-STK 2421-0913 2421-1319 2421-1319-STK Length, inch (cm) Min Heating Elements Grid Format Power Tabs Modulation 2 Voltage Max Peak Current 3 (Amp) Short Long Fuse (Amp) Drawing? Stick Kit Price 25.00 (63.5) 27 (69) 40 (102) 20 10 Ser 2Par 100% L 24 10.2 6.9 15.0 Yes 25.00 (63.5) 44 (112) 57 (145) 20 5 Ser 4Par 50% L/R 24 25.0 19.4 20.0 Yes 25.00 (63.5) 54 (137) 80 (203) 20 5 Ser 4Par 100% L/R 24 20.4 13.8 25.0 Yes 26.25 (66.7) 09 (23) 13 (33) 21 1 Ser 21Par 50% L/R 24 7.2 4.9 7.5 Yes 26.25 (66.7) 13 (33) 19 (48) 21 1 Ser 21Par 100% L/R 24 5.1 3.4 7.5 Yes $82.95 Full Kit Price $117.95 $118.40 $83.85 $118.85 $119.30 $84.75 $119.75 2421-2429 26.25 (66.6) 24 (61) 29 (73) 21 7 Ser 3Par 25% L/R 24 25.0 20.6 15.0 Yes $120.20 2421-2740 26.25 (66.6) 27 (69) 40 (102) 21 7 Ser 3Par 50% L/R 24 21.6 14.6 20.0 Yes $120.65 26.25 (66.6) 39 (99) 57 (145) 21 7 Ser 3Par 100% L/R 24 15.3 10.3 20.0 Yes 27.50 (69.9) 09 (23) 13 (33) 22 1 Ser 22Par 50% L 24 7.2 4.9 7.5 Yes 27.50 (69.9) 12 (30) 18 (46) 22 1 Ser 22Par 100% L 24 5.1 3.4 7.5 Yes 2422-1013 27.50 (69.9) 10 (25) 13 (33) 22 2 Ser 11Par 12% L/R 24 25.0 19.4 10.0 Yes $122.45 2422-1218 27.50 (69.9) 12 (30) 18 (46) 22 2 Ser 11Par 25% L/R 24 20.4 13.8 15.0 Yes $122.90 2422-1726 27.50 (69.9) 17 (43) 26 (66) 22 2 Ser 11Par 50% L/R 24 14.4 9.7 15.0 Yes $123.35 27.50 (69.9) 25 (64) 36 (91) 22 11 Ser 2Par 100% L/R 24 10.2 6.9 15.0 Yes 28.75 (73.0) 08 (20) 12 (30) 23 1 Ser 23Par 50% L 24 7.2 4.9 7.5 Yes 28.75 (73.0) 12 (30) 17 (43) 23 1 Ser 23Par 100% L 24 5.1 3.4 7.5 Yes 30.00 (76.2) 08 (20) 12 (30) 24 1 Ser 24Par 50% L/R 24 7.2 4.9 7.5 Yes 30.00 (76.2) 11 (28) 17 (43) 24 1 Ser 24Par 100% L/R 24 5.1 3.4 7.5 Yes 2424-0912-L 30.00 (76.2) 09 (23) 12 (30) 24 2 Ser 12Par 12% L 24 25.0 19.4 10.0 Yes $126.05 2424-1117-L 30.00 (76.2) 11 (28) 17 (43) 24 2 Ser 12Par 25% L 24 20.4 13.8 15.0 Yes $126.50 2424-1624-L 30.00 (76.2) 16 (41) 24 (61) 24 2 Ser 12Par 50% L 24 14.4 9.7 15.0 Yes $126.95 30.00 (76.2) 23 (58) 33 (84) 24 2 Ser 12Par 100% L 24 10.2 6.9 15.0 Yes 2424-2125-L 30.00 (76.2) 21 (53) 25 (64) 24 3 Ser 8Par 25% L 24 25.0 20.6 15.0 Yes $127.85 2424-2435-L 30.00 (76.2) 24 (61) 35 (89) 24 3 Ser 8Par 50% L 24 21.6 14.6 20.0 Yes $128.30 2421-3957 2421-3957-STK 2422-0913-L 2422-1218-L 2422-2536 2422-1218-L-STK 2422-2536-STK 2423-0812-L 2423-1217-L 2423-1217-L-STK 2424-0812 2424-1117 2424-2333-L 24 Volt 2424-1117-STK 2424-2333-L-STK Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com $86.10 $121.10 $121.55 $87.00 $88.20 $122.00 $123.80 $124.25 $89.70 $124.70 $125.15 $90.60 $92.40 $125.60 $127.40 Page 11 of 78 Full Defroster Part Number 1 Stick Kit Part Number Start here, select height 2424-3450-L 2424-3450-L-STK 2424-3747-L Height inch (cm) Length, inch (cm) Min Heating Elements Grid Format Power Tabs Modulation 2 Voltage Max Peak Current 3 (Amp) Short Long Fuse (Amp) Drawing? Stick Kit Price 30.00 (76.2) 34 (86) 50 (127) 24 8 Ser 3Par 100% L 24 15.3 10.3 20.0 Yes 30.00 (76.2) 37 (94) 47 (119) 24 6 Ser 4Par 50% L 24 25.0 19.4 20.0 Yes $93.75 Full Kit Price $128.75 $129.20 2424-4567-L 2424-4567-L-STK 30.00 (76.2) 45 (114) 67 (170) 24 6 Ser 4Par 100% L 24 20.4 13.8 25.0 Yes $94.65 $129.65 2427-3044 2427-3044-STK 33.25 (84.4) 30 (76) 44 (112) 27 9 Ser 3Par 100% L/R 24 15.3 10.3 20.0 Yes $95.10 $130.10 33.25 (88.9) 31 (79) 40 (102) 28 7 Ser 4Par 50% L/R 24 25.0 19.4 20.0 Yes 33.25 (88.9) 39 (99) 57 (145) 28 7 Ser 4Par 100% L/R 24 20.4 13.8 25.0 Yes 2428-3140 2428-3957 2428-3957-STK $130.55 $96.00 $131.00 1. Stick Kit Defrosters. Include only the defroster. No wire harness, installation kit or controls are included. 2. Connection Tabs. in (L) indicates all tabs on left while (L/R) indicates tabs on the left and right. Defrosters can be rotated for optimum tab alignment. See part drawing. 3. Amperage. Shorter defrosters pull more amperage than longer defrosters. 4. Two Element Defrosters. These defrosters require longer tabs so overall height is larger than standard. © 2011 Planned Products LLC, All rights reserved. Frost Fighter and ThermaSync are registered Trademarks of Planned Products LLC. 24 Volt Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 12 of 78 ® ThermaSync Defroster Controls and Accessories Part No. Description 2712 Defroster Control and Switch – 12 Volt 2812 Defroster Control and Switch – 12 Volt 2724 Defroster Control and Switch – 24 Volt 2824 Defroster Control and Switch – 24 Volt ThermaSync RELAY controls provide an attractive defroster switch and relay with standard ten minute automatic shut off timing. Includes the ThermaSync control, switch and full instructions. ThermaSync MOSFET controls provide power modulation, selectable automatic shutoff timing and full SwitchBoss network compatibility. The control can configured to shut off from 10 to 160 minutes or activated manually. Includes the ThermaSync control, switch and instructions. ThermaSync RELAY controls provide an attractive defroster switch and relay with standard ten minute automatic shut off timing. Includes the ThermaSync control, switch and full instructions. *24 Volt RELAY available with longer lead times. ThermaSync MOSFET controls provide power modulation, selectable automatic shutoff timing and full Switch Boss network compatibility. The control can configured to shut off from 10 to 160 minutes. Includes the ThermaSync control, switch and instructions. Type / Voltage Price ea. RELAY 12 Volts $33.95 MOSFET 12 Volts $39.95 RELAY* 24 Volts $43.95 MOSFET 24 Volts $49.95 2728 Wire Harness Installation Pack 12/24 Volts $28.95 2730 Switch Boss Defroster Control 12/24 Volts $36.95 2745 Tab Adaptor Wire Harness 12/24 Volts $8.95 The ThermSync installation pack makes it easy to install ThermaSync Defroster Controls. Includes a wire harness with color coded connectors, fuse, fuse holder, switch mounting plate, power tap, spare connectors, wire ties and full instructions. Does not include control or switch. This control enables several Clear View II defrosters to be activated from a single master switch. Each defroster’s ThermaSync control is plugged into the SwitchBoss. Up to four defrosters per SwitchBoss can be used. The networked defrosters can be different sizes. Automatic timing is set by the Master. Connectors and wire to adapt existing defroster connectors to work with the Clear View II defroster tab locations. Includes ground wire and power wire to extend a vehicle’s existing connector wires to work with any defrosters tab location. Plugs into defroster connector and Clear View defroster tabs. Planned Products LLC 4699 Nautilus Court S. Suite 201 Boulder, CO 80301 24 Volt Image Tel: 303.682.0274 Fax: 303.682.0678 info1@frostfighter.com www.frostfighter.com Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 13 of 78 4.12 in (10.4) 2 Elements - Grid: Parallel-1, Series-2 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2402-2835-L 3% 27.5 (71) 35.4 in (89) 25.0A 4.4A 0.8A 5.0A 19.4A 3.4A 0.6A 5.0A 2402-3450-L 6% 33.8 in (86) 50.0 in (127) 20.4A 5.1A 1.3A 7.5A 13.8A 3.4A 0.9A 7.5A 2402-4871-L 12% 47.8 in (122) 70.8 in (180) 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2402-6884-L 25% 67.5 in (173) 84.0 in (213) 10.2A 5.1A 2.5A 7.5A 8.2A 4.1A 2.0A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 14 of 78 3.75 in (9.5) 3 Element - Grid: Parallel-1, Series-3 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2403-1824 3% 18.3 in (46) 23.6 in (61) 25.0A 4.4A 0.8A 5.0A 19.4A 3.4A 0.6A 5.0A 2403-2333 6% 22.5 in (58) 33.3 in (84) 20.4A 5.1A 1.3A 7.5A 13.8A 3.4A 0.9A 7.5A 2403-3247 12% 31.9 in (81) 47.2 in (119) 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2403-4567 25% 45.0 in (114) 66.7 in (170) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 15 of 78 3.75 in (9.5) 3 Element - Grid: Parallel-1, Series-3 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2403-6484 50% 63.6 in (163) 84.0 in (213) 7.2A 5.1A 3.6A 7.5A 5.5A 3.9A 2.7A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 16 of 78 5.00 in (12.7) 4 Elements - Grid: Parallel-1, Series-4 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2404-1418-L 3% 13.8 in (36) 17.7 in (46) 25.0A 4.4A 0.8A 5.0A 19.4A 3.4A 0.6A 5.0A 2404-1725-L 6% 16.9 in (43) 25.0 in (64) 20.4A 5.1A 1.3A 7.5A 13.8A 3.4A 0.9A 7.5A 2404-2435-L 12% 23.9 in (61) 35.4 in (89) 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2404-3450-L 25% 33.8 in (86) 50.0 in (127) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 17 of 78 5.00 in (12.7) 4 Elements - Grid: Parallel-1, Series-4 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2404-4871-L 50% 47.7 in (122) 70.7 in (180) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2404-6884-L 2404-6884-L-STK 100% 67.5 in (173) 84.0 in (213) 5.1A 5.1A 5.1A 7.5A 4.1A 4.1A 4.1A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 18 of 78 5.00 in (12.7) 4 Elements - Grid: Parallel-2, Series-2 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2404-5571-L 12% 55.0 in (140) 70.8 in (180) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2404-6884-L1 25% 67.5 in (173) 84.0 in (213) 20.4A 10.2A 5.1A 15.0A 16.4A 8.2A 4.1A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 19 of 78 6.25 in (15.8) 5 Elements - Grid: Parallel-1, Series-5 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2405-1114 3% 11.0 in (28) 14.2 in (36) 25.0A 4.4A 0.8A 5.0A 19.4A 3.4A 0.6A 5.0A 2405-1420 6% 13.5 in (36) 20.0 in (51) 20.4A 5.1A 1.3A 7.5A 13.8A 3.4A 0.9A 7.5A 2405-1928 12% 19.1 in (48) 28.3 in (71) 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2405-2740 25% 27.0 in (69) 40.0 in (102) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 20 of 78 6.25 in (15.8) 5 Elements - Grid: Parallel-1, Series-5 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2405-3857 50% 38.2 in (97) 56.6 in (145) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2405-5480 2405-5480-STK 100% 54.0 in (137) 80.0 in (203) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 21 of 78 7.50 in (19.0) 6 Elements - Grid: Parallel-1, Series-6 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2406-0912-L 3% 9.2 in (23) 11.8 in (30) 25.0A 4.4A 0.8A 5.0A 19.4A 3.4A 0.6A 5.0A 2406-1117-L 6% 11.3 in (28) 16.7 in (43) 20.4A 5.1A 1.3A 7.5A 13.8A 3.4A 0.9A 7.5A 2406-1624-L 12% 15.9 in (41) 23.6 in (61) 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2406-2333-L 25% 22.5 in (58) 33.3 in (84) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 22 of 78 7.50 in (19.0) 6 Elements - Grid: Parallel-1, Series-6 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2406-3247-L 50% 31.8 in (81) 47.1 in (119) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2406-4567-L 2406-4567-L-STK 100% 45.0 in (114) 66.7 in (170) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 23 of 78 7.50 in (19.0) 6 Elements - Grid: Parallel-2, Series-3 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2406-3747 12% 36.7 in (94) 47.2 in (119) 25.0A 8.9A 3.1A 5.1A. 10.0A 19.4A 6.9A 2.4A 3.4A 10.0A 2406-4567 25% 45.0 in (114) 66.7 in (170) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A 2406-6484 50% 63.6 in (163) 84.0 in (213) 14.4A 10.2A 7.2A 15.0A 10.9A 7.7A 5.5A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 24 of 78 8.75 in (22.2) 7 Elements - Grid: Parallel-1, Series-7 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2407-0810 3% 8.0 in (20) 10.1 in (25) Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2407-1014 6% 9.6 in (24) 14.3 in (36) Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2407-1420 12% 13.7 in (36) 20.2 in (51) Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 24.6A 4.3A 0.8A 5.0A 20.4A 5.1A 1.3A 7.5A 14.4A 5.1A 1.8A 7.5A 19.4A 3.4A 0.6A 5.0A 13.8A 3.4A 0.9A 7.5A 9.7A 3.4A 1.2A 7.5A 2407-1929 25% 19.3 in (48) 28.6 in (74) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 25 of 78 8.75 in (22.2) 7 Elements - Grid: Parallel-1, Series-7 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2407-2740 50% 27.3 in (69) 40.4 in (102) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2407-3957 2407-3957-STK 100% 38.6 in (99) 57.1 in (145) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 26 of 78 10.00 in (25.4) 8 Elements - Grid: Parallel-1, Series-8 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2408-0913-L 6% 9.0 in (23) 12.5 in (33) 19.1A 4.8A 1.2A 5.0A 13.8A 3.4A 0.9A 5.0A 2408-1218-L 12% 11.9 in (30) 17.7 in (46) 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2408-1725-L 25% 16.9 in (43) 25.0 in (64) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 27 of 78 10.00 in (25.4) 8 Elements - Grid: Parallel-1, Series-8 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2408-2435-L 50% 23.9 in (61) 35.4 in (89) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2408-3450-L1 2408-3450-L1-STK 100% 33.8 in (86) 50.0 in (127) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 28 of 78 10.00 in (25.4) 8 Elements - Grid: Parallel-2, Series-4 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2408-2835-L 12% 27.5 in (71) 35.4 in (89) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2408-3450-L 25% 33.8 in (86) 50.0 in (127) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A 2408-4871-L 50% 47.7 in (122) 70.7 in (180) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A 2408-6884-L 2408-6884-L-STK 100% 67.5 in (173) 84.0 in (213) 10.2A 10.2A 10.2A 15.0A 8.2A 8.2A 8.2A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 29 of 78 11.25 in (28.6) 9 Elements - Grid: Parallel-1, Series-9 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2409-1116 12% 10.6 in (28) 15.7 in (41) Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2409-1522 25% 15.0 in (38) 22.2 in (56) Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 14.4A 5.1A 1.8A 7.5A 10.2A 5.1A 2.5A 7.5A 9.7A 3.4A 1.2A 7.5A 6.9A 3.4A 1.7A 7.5A 2409-2131 50% 21.2 in (53) 31.4 in (79) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2409-3044 2409-3044-STK 100% 30.0 in (76) 44.4 in (112) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 30 of 78 11.25 in (28.6) 9 Elements - Grid: Parallel-3, Series-3 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2409-5567 25% 55.0 in (140) 66.7 in (170) 25.0A 12.5A 6.3A 15.0A 20.6A 10.3A 5.2A 15.0A 2409-6484 50% 63.6 in (163) 84.0 in (213) 21.6A 15.3A 10.8A 20.0A 16.4A 11.6A 8.2A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 31 of 78 12.50 in (31.7) 10 Elements - Grid: Parallel-1, Series-10 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2410-1420-L 25% 13.5 in (36) 20.0 in (51) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2410-1928-L 50% 19.1 in (48) 28.3 in (71) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2410-2740-L 2410-2740-L-STK 100% 27.0 in (69) 40.0 in (102) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 32 of 78 12.50 in (31.7) 10 Elements - Grid: Parallel-2, Series-5 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2410-2228 12% 22.0 in (56) 28.3 in (71) 25.0A 8.9A 3.1A 10.0A Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2410-2740 25% 27.0 in (69) 40.0 in (102) Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2410-3857 50% 38.2 in (97) 56.6 in (145) Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 2410-5480 2410-5480-STK 100% 54.0 in (137) 80.0 in (203) 24 Volt 20.4A 10.2A 5.1A 15.0A 14.4A 10.2A 7.2A 15.0A 10.2A 10.2A 10.2A 15.0A 19.4A 6.9A 2.4A 10.0A 13.8A 6.9A 3.4A 15.0A 9.7A 6.9A 4.9A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 33 of 78 13.75 in (34.9) 11 Elements - Grid: Parallel-1, Series-11 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Max. Current Peak RMS Avg. Fuse 24 Volt 2411-1218 25% 12.3 in (30) 18.2 in (46) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2411-1726 50% 17.4 in (43) 25.7 in (66) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2411-2536 2411-2536-STK 100% 24.5 in (64) 36.4 in (91) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 34 of 78 15.00 in (38.1) 12 Elements - Grid: Parallel-1, Series-12 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2412-0812-L 12% 8.0 in 11.8 in 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2412-1117-L 25% 11.3 in 16.7 in 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2412-1624-L 50% 15.9 in (41) 23.6 in (61) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 35 of 78 15.00 in (38.1) 12 Elements - Grid: Parallel-1, Series-12 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2412-2333-L1 2412-2333-L1-STK 100% 22.5 in (58) 33.3 in (84) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 36 of 78 15.00 in (38.1) 12 Elements - Grid: Parallel-2, Series-6 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2412-1824-L 12% 18.3 in (46) 23.6 in (61) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2412-2333-L 25% 22.5 in (58) 33.3 in (84) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A 2412-3247-L 50% 31.8 in (81) 47.1 in (119) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 37 of 78 15.00 in (38.1) 12 Elements - Grid: Parallel-2, Series-6 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2412-4567-L 2412-4567-L-STK 100% 45.0 in (114) 66.7 in (170) 10.2A 10.2A 10.2A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 38 of 78 15.00 in (38.1) 12 Elements - Grid: Parallel-3, Series-4 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2412-4150-L 25% 41.3 in (105) 50.0 in (127) 25.0A 12.5A 6.3A 15.0A 20.6A 10.3A 5.2A 15.0A 2412-4871-L 50% 47.7 in (122) 70.7 in (180) 21.6A 15.3A 10.8A 20.0A 14.6A 10.3A 7.3A 20.0A 2412-6884-L 2412-6884-L-STK 100% 67.5 in (173) 84.0 in (213) 15.3A 15.3A 15.3A 20.0A 12.3A 12.3A 12.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 39 of 78 16.25 in (41.3) 13 Elements - Grid: Parallel-1, Series-13 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2413-0711 12% 7.4 in (18) 10.9 in (28) 14.4A 5.1A 1.8A 7.5A 9.7A 3.4A 1.2A 7.5A 2413-1015 25% 10.4 in (25) 15.4 in (38) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2413-1522 50% 14.7 in (38) 21.8 in (56) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 40 of 78 Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2413-2131 2413-2131-STK 100% 20.8 in (53) 30.8 in (79) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 41 of 78 17.50 in (44.4) 14 Elements - Grid: Parallel-1, Series-14 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2414-1014-L 25% 9.6 in (25) 14.3 in (36) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2414-1420-L 50% 13.6 in (36) 20.2 in (51) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2414-1929-L 2414-1929-L-STK 100% 19.3 in (48) 28.6 in (74) 3.4A 3.4A 3.4A 7.5A 5.1A 5.1A 5.1A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 42 of 78 17.50 in (44.4) 14 Elements - Grid: Parallel-2, Series-7 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2414-1620 12% 15.7 in (41) 20.2 in (51) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2414-1929 25% 19.3 in (48) 28.6 in (74) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A 2414-2740 50% 27.3 in (69) 40.4 in (102) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 43 of 78 17.50 in (44.4) 14 Elements - Grid: Parallel-2, Series-7 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2414-3957 2414-3957-STK 100% 38.6 in (99) 57.1 in (145) 10.2A 10.2A 10.2A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 44 of 78 18.75 in (47.6) 15 Elements - Grid: Parallel-1, Series-15 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2415-0913 25% 9.0 in (23) 13.3 in (33) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2415-1319 50% 12.7 in (33) 18.9 in (48) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2415-1827 2415-1827-STK 100% 18.0 in (46) 26.7 in (69) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 45 of 78 18.75 in (47.6) 15 Elements - Grid: Parallel-3, Series-5 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2415-3340 25% 33.0 in (84) 40.0 in (102) 25.0A 12.5A 6.3A 15.0A 20.6A 10.3A 5.2A 15.0A 2415-3857 50% 38.2 in (97) 56.6 in (145) 21.6A 15.3A 10.8A 20.0A 14.6A 10.3A 7.3A 20.0A 2415-5480 2415-5480-STK 100% 54.0 in (137) 80.0 in (203) 15.3A 15.3A 15.3A 20.0A 10.3A 10.3A 10.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 46 of 78 20.00 (50.8) 16 Elements - Grid: Parallel-1, Series-16 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2416-0813-L 25% 8.4 in (20) 12.5 in (33) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2416-1218-L 50% 11.9 in (30) 17.7 in (46) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2416-1725-L1 2416-1725-L1-STK 100% 17.3 in (43) 25.0 in (64) 5.0A 5.0A 5.0A 5.0A 3.4A 3.4A 3.4A 5.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 47 of 78 20.00 (50.8) 16 Elements - Grid: Parallel-2, Series-8 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2416-1418-L 12% 13.8 in (36) 17.7 in (71) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2416-1725-L 25% 17.3 in (43) 25.0 in (64) 19.9A 9.9A 5.0A 10.0A 13.8A 6.9A 3.4A 10.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 48 of 78 20.00 (50.8) 16 Elements - Grid: Parallel-2, Series-8 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2416-2435-L 50% 23.9 in (61) 35.4 in (89) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A 2416-3450-L 2416-3450-L-STK 100% 33.8 in (86) 50.0 in (127) 10.2A 10.2A 10.2A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 49 of 78 20.00 (50.8) 16 Elements - Grid: Parallel-4, Series-4 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2416-5571-L 50% 55.0 in (140) 70.7 in (180) 25.0A 17.7A 12.5A 20.0A 19.4A 13.8A 9.7A 20.0A 2416-6884-L 2416-6884-L-STK 100% 67.5 in (173) 84.0 in (213) 20.4A 20.4A 20.4A 25.0A 16.4A 16.4A 16.4A 25.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 50 of 78 21.25 in (53.97) 17 Elements - Grid: Parallel-1, Series-17 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2417-0812 25% 7.9 in (20) 11.8 in (30) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2417-1117 50% 11.2 in (28) 16.6 in (43) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2417-1624 2417-1624-STK 100% 15.9 in (41) 23.5 in (61) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 51 of 78 22.5 in (57.1) 18 Elements - Grid: Parallel-1, Series-18 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2418-0811-L 25% 7.5 in (20) 11.1 in (28) 10.2A 5.1A 2.5A 7.5A 6.9A 3.4A 1.7A 7.5A 2418-1116-L 50% 10.6 in (28) 15.7 in (41) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 52 of 78 22.5 in (57.1) 18 Elements - Grid: Parallel-1, Series-18 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2418-1522-L 2418-1522-L-STK 100% 15.0 in (38) 22.2 in (55) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 53 of 78 22.5 in (57.1) 18 Elements - Grid: Parallel-2, Series-9 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2418-1216 12% 12.2 in (30) 15.7 in (41) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2418-1522 25% 15.0 in (38) 22.2 in (56) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 54 of 78 22.5 in (57.1) 18 Elements - Grid: Parallel-2, Series-9 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2418-2131 50% 21.2 in (53) 31.4 in (79) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 55 of 78 22.5 in (57.1) 18 Elements - Grid: Parallel-2, Series-9 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2418-3044 2418-3044-STK 100% 30.0 in (76) 44.4 in (112) 10.2A 10.2A 10.2A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 56 of 78 22.5 in (57.1) 18 Elements - Grid: Parallel-3, Series-6 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2418-2833-L 25% 27.5 in (71) 33.3 in (84) 25.0A 12.5A 6.3A 15.0A 20.6A 10.3A 5.2A 15.0A 2418-3247-L 50% 31.8 in (81) 47.1 in (119) 21.6A 15.3A 10.8A 20.0A 14.6A 10.3A 7.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 57 of 78 22.5 in (57.1) 18 Elements - Grid: Parallel-3, Series-6 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2418-4567-L 2418-4567-L-STK 100% 45.0 in (114) 66.7 in (170) 15.3A 15.3A 15.3A 20.0A 10.3A 10.3A 10.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 58 of 78 23.75 in (60.33) 19 Elements - Grid: Parallel-1, Series-19 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2419-1015 50% 10.0 in (25) 14.9 in (38) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2419-1421 2419-1421-STK 100% 14.2 in (36) 21.1 in (53) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 59 of 78 25 in (63.50) 20 Elements - Grid: Parallel-1, Series-20 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2420-1014-L 50% 9.5 in (25) 14.1 in (36) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2420-1420-L1 2420-1420-L1-STK 100% 13.5 in (36) 20.0 in (51) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 60 of 78 25 in (63.50) 20 Elements - Grid: Parallel-1, Series-20 24V Part Number: Modulation: Min ( ). Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2420-1114-L 12% 11.0 in (28) 14.2 in (36) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2420-1420-L 25% 13.5 in (36) 20.0 in (51) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 61 of 78 25 in (63.50) 20 Elements - Grid: Parallel-1, Series-20 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2420-1928-L 50% 19.1 in (48) 28.3 in (71) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A 2420-2740-L 2420-2740-L-STK 100% 27.0 in (69) 40.0 in (102) 10.2A 10.2A 10.2A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 62 of 78 25.00 in (63.5) 20 Elements - Grid: Parallel-4, Series-5 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2420-4457 50% 44.0 in (112) 56.6 in (145) 25.0A 17.7A 12.5A 20.0A 19.4A 13.8A 9.7A 20.0A 2420-5480 2420-5480-STK 100% 54.0 in (137) 80.0 in (203) 20.4A 20.4A 20.4A 25.0A 13.8A 13.8A 13.8A 25.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 63 of 78 26.25 in (66.6) 21 Elements - Grid: Parallel-1, Series-21 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2421-0913 50% 9.1 in (23) 13.5 in (33) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2421-1319 100% 12.9 in (33) 19.0 in (48) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 64 of 78 26.25 in (66.6) 21 Elements - Grid: Parallel-3, Series-7 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2421-2429 25% 23.6 in (61) 28.6 in (74) 25.0A 12.5A 6.3A 15.0A 20.6A 10.3A 5.2A 15.0A 2421-2740 50% 27.3 in (69) 40.4 in (102) 21.6A 15.3A 10.8A 20.0A 14.6A 10.3A 7.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 65 of 78 26.25 in (66.6) 21 Elements - Grid: Parallel-3, Series-7 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2421-3957 2421-3957-STK 100% 38.6 in (99) 57.1 in (145) 15.3A 15.3A 15.3A 20.0A 10.3A 10.3A 10.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 66 of 78 27.50 in (69.8) 22 Elements - Grid: Parallel-2, Series-11 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2422-1013 12% 10.0 in (25) 12.9 in (33) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2422-1218 25% 12.3 in (30) 18.2 in (46) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 67 of 78 27.50 in (69.8) 22 Elements - Grid: Parallel-2, Series-11 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2422-1726 50% 17.4 in (43) 25.7 in (66) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A 2422-2536 2422-2536-STK 100% 24.5 in (64) 36.4 in (91) 10.2A 10.2A 10.2A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 68 of 78 30 in (76.2) 24 Elements - Grid: Parallel-1, Series-24 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2424-0812-L 50% 8.0 in (20) 11.8 in (30) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2424-1117-L 2424-1117-L-STK 100% 11.3 in (28) 16.7 in (43) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 69 of 78 30 in (76.2) 24 Elements - Grid: Parallel-2, Series-12 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2424-0912-L 12% 9.2 in (23) 11.8 in (30) 25.0A 8.9A 3.1A 10.0A 19.4A 6.9A 2.4A 10.0A 2424-1117-L 25% 11.3 in (28) 16.7 in (43) 20.4A 10.2A 5.1A 15.0A 13.8A 6.9A 3.4A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 70 of 78 30 in (76.2) 24 Elements - Grid: Parallel-2, Series-12 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2424-1624-L 50% 15.9 in (41) 23.6 in (61) 14.4A 10.2A 7.2A 15.0A 9.7A 6.9A 4.9A 15.0A 2424-2333-L 2424-2333-L-STK 100% 22.5 in (58) 33.3 in (84) 10.2A 10.2A 10.2A 15.0A 6.9A 6.9A 6.9A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 71 of 78 30.00 in (76.2) 24 Elements - Grid: Parallel-3, Series-8 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2424-2125-L 25% 20.6 in (53) 25.0 in (64) 25.0A 12.5A 6.3A 15.0A 20.6A 10.3A 5.2A 15.0A 2424-2635-L 50% 25.7 in (66) 35.4 in (89) 20.1A 14.2A 10.0A 15.0A 14.6A 10.3A 7.3A 15.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 72 of 78 30.00 in (76.2) 24 Elements - Grid: Parallel-3, Series-8 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2424-3450-L 2424-3450-L-STK 100% 33.8 in (86) 50.0 in (127) 15.3A 15.3A 15.3A 20.0A 10.3A 10.3A 10.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 73 of 78 30.00 in (76.2) 24 Elements - Grid: Parallel-4, Series-6 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2424-3747-L 50% 36.7 in (94) 47.1 in (119) 25.0A 17.7A 12.5A 20.0A 19.4A 13.8A 9.7A 20.0A 2424-4567-L 2424-4567-L-STK 100% 45.0 in (114) 66.7 in (170) 20.4A 20.4A 20.4A 25.0A 13.8A 13.8A 13.8A 25.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 74 of 78 30.00 in (76.2) 24 Elements - Grid: Parallel-4, Series-6 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse art Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2425-0811 50% 7.6 in (20) 11.3 in (28) 7.2A 5.1A 3.6A 7.5A 4.9A 3.4A 2.4A 7.5A 2425-1116 2425-1116-STK 100% 10.8 in (28) 16.0 in (41) 5.1A 5.1A 5.1A 7.5A 3.4A 3.4A 3.4A 7.5A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 75 of 78 33.75 in (85.7) 27 Elements - Grid: Parallel-3, Series-9 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2427-3044 2427-3044-STK 100% 30.0 in (76) 44.4 in (112) 15.3A 15.3A 15.3A 20.0A 10.3A 10.3A 10.3A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 76 of 78 35 in (88.9) 28 Elements - Grid: Parallel-3, Series-7 24V Part Number: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2428-3140 50% 31.4 in (79) 40.4 in (102) 25.0A 17.7A 12.5A 20.0A 19.4A 13.8A 9.7A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 77 of 78 35 in (88.9) 28 Elements - Grid: Parallel-3, Series-7 24V Part Number: Stick Kit: Modulation: Min. Length Max. Length Current Peak RMS Avg. Fuse 24 Volt 2428-3957 2428-3957-STK 100% 38.6 in (99) 57.1 in (145) 20.4A 20.4A 20.4A 25.0A 13.8A 13.8A 13.8A 20.0A Frost Fighter Clear View Defrosters Ver. 32 01.14.2014 © 2012 Planned Products LLC www.frostfighter.com Page 78 of 78