transducers

advertisement
transducers
Transducer Selection Chart
Below is a chart that details which amplifier is used for measurement of
a specific physiological parameter. Follow down the left hand column until
you reach the parameter you want to measure and then move towards the
right until you reach the column that displays the species you are studying
may be a single transducer/sensor or multiple units to select from. Please
see individual pages for complete product details.
Transducer Selection Chart
Physiological Signal
Amplifier
Left Ventricular
Pressure-Volume
MPVS Ultra
Mouse and Rat
MPVS Ultra
All animals
PY2 72-9739
PY2 72-9724
Some typical cardiovascular setups are shown below.
Pressure-Volume Measurement
transducers
2F Pressure-volume
catheter, SPR-838
MPVS Ultra Hardware
Cardiovascular
For Blood Pressure Measurements
Left Ventricular
Pressure (LVP)
TAM-A
HEC-10D Cable
PY2 73-0065
PY2 72-9843
Aortic Pressure (AP)
TAM-A
PY2 73-0065
Venous Pressures (VP)
TAM-A
TAM-D
PY2 73-0065
PY2 73-1793
Pulmonary Artery pressure (PAP)
TAM-A
PY2 73-0065
Aortic Flow (AF)
TTFM
PY2 73-0146
Carotid Artery Flow (CAF)
TTFM
PY2 73-0146
Femoral Artery Flow (FAF)
TTFM
PY2 73-0146
Coronary Artery Flow (CF)
TTFM
PY2 73-0146
ECG
ECGA
EGM
WLA
PY2 73-0149
PY2 73-1778
PY2 73-1779
MAP
BPA
MAPM 3ch
MAPM 6ch
PY2 73-0153
PY2 73-3080
PY2 73-1780
Sement Length, Wall Thickness
EIM**
SNM**
PY2 73-0222
PY2 73-0218
Wall Thickening
EIM**
DDM**
PY2 73-0222
PY2 73-0785
Temperature
TCAM
PY2 73-1792
Aortic Pressure
APT 300
TAM-A
TAM-D
Venous Pressure
(P75)
For Blood Flow Measurements
Pressure-Volume
Catheters
Peripheral,
Coronary Flow
TTFM
J2
Aortic Flow
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
Rat/Guinea Pig
Rabbit/Cat
Dog
Pig
PVR-1045
PVR-1035
PVR-1030
SPR-839
PY2 72-9721
PY2 72-9722
PY2 72-9740
PY2 72-9723
SPR-869
SPR-838
PY2 72-9745
PY2 72-9736
SPR-550
SPR-554
SPR-560
Notes
Notes
Notes
SPR-550
SPR-554
SPR-560
SPR-562
Notes
Notes
PY2 72-9767
PY2 72-9729
SPR-560
SPR-562
SPR-570
SPR-592
PY2 72-9767
PY2 72-9722
Notes
PY2 72-9729
SPR-1000
PY2 72-9781
SPR-671
SPR-407
PY2 72-9779
PY2 72-9775
SPC-320
SPC-330
SPC-340
Notes
Notes
Notes
SPC-350
SPC-360
SPC-370
Notes
Notes
Notes
SPC-350
SPC-360
SPC-370
Notes
Notes
Notes
APT300
PY2 73-3862
PY2 73-3862
PY2 73-3862
PY2 73-3862
PY2 73-3862
P75
PY2 73-0020
PY2 73-0020
PY2 73-0020
PY2 73-0020
PY2 73-0020
P75
PY2 73-0020
PY2 73-0200
PY2 73-0200
PY2 73-0200
PY2 73-0200
1.0PRB
1.5PRB
PY2 73-4091
PY2 73-4093
2PSB
2.5PSB
PY2 73-4068
PY2 73-4070
4PSB
6PSB
8PSB
PY2 73-4075
PY2 73-4077
PY2 73-4079
14AX
16AX
20AX
28AX
PY2 73-4095
PY2 73-4096
PY2 73-4097
PY2 73-4099
16AX
20AX
24AX
28AX
PY2 73-4096
PY2 73-4097
PY2 73-4098
PY2 73-4099
0.5VB
0.75VB
PY2 73-4066
PY2 73-4067
1PRB
1.5PRB
2PSB
PY2 73-4091
PY2 73-4093
PY2 73-4068
1.5PRB
2PSB
2.5PSB
PY2 73-4093
PY2 73-4068
PY2 73-4070
3PSB
4PSB
6PSB
8PSB
PY2 73-4073
PY2 73-4075
PY2 73-4077
PY2 73-4079
8PSB
10PSB
12PSB
14PSB
16PSB
PY2 73-4079
PY2 73-4081
PY2 73-4083
PY2 73-4085
PY2 73-4087
0.5VB
0.75VB
PY2 73-4066
PY2 73-4067
1PRB
1.5PRB
2PSB
PY2 73-4091
PY2 73-4093
PY2 73-4068
1.5PRB
2PSB
2.5PSB
PY2 73-4093
PY2 73-4068
PY2 73-4070
3PSB
4PSB
6PSB
8PSB
PY2 73-4073
PY2 73-4075
PY2 73-4077
PY2 73-4079
8PSB
10PSB
12PSB
14PSB
16PSB
PY2 73-4079
PY2 73-4081
PY2 73-4083
PY2 73-4085
PY2 73-4087
-
-
-
-
1PRB
2PSB
PY2 73-4091
PY2 73-4068
1PRB
2PRB
3PRB
PY2 73-4091
PY2 73-4068
PY2 73-4073
2PSB
3PSB
4PSB
PY2 73-4068
PY2 73-4073
PY2 73-4075
comes with needle elec.
comes with needle elec.
Needles
adhesive
PY2 59-8526
PY2 73-3022
Needles
adhesive
adhesive
PY2 59-8546
PY2 73-3022
PY2 73-3023
Needles
adhesive
adhesive
PY2 59-8546
PY2 73-3022
PY2 73-3023
Micro
PY2 73-3840
Tip
PY2 73-0150
Standard
PY2 73-0409
Standard
PY2 73-0409
Standard
PY2 73-0409
-
-
SA5-2
PY2 73-3463
SL5-2
PY2 73-0217
SL5-2
WT5-2
PY2 73-0217
PY2 73-0618
SL5-2
WT5-2
PY2 73-0217
PY2 73-0618
-
-
-
-
DMT20-1
DMT20-2
PY2 73-3466
PY2 73-3467
DMR-10-1
DMT-10.2
PY2 73-3464
PY2 73-3465
DMR-10-1
DMT-10.2
PY2 73-3464
PY2 73-3465
RET-3
PY2 52-1591
RET-2
PY2 52-1583
RET-1
PY2 52-1526
RET-1
PY2 52-1526
RET-1
PY2 52-1526
transducers
Mouse
transducers
Cardiovascular
Transducer Selection Chart
The measurement of dimensions (wall thickness, segment length, wall thickening) requires an external amplifier system (System 6 case PY2 73-0216 with Sonomicrometer
Module PY2 73-0218 or Doppler displacement Module PY2 73-0785), the signals are linked to the PLUGSYS system using the EIM module exist in different configuration,
see pages J12-13 for detailed specifications and ordering information.
✐
NOTE: Please contact your local Harvard
Apparatus Representative or our Technical
Support Team to configure a system to your
requirements.
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
J3
transducers
RGBP Research Grade Blood Pressure Transducer
Research Grade Blood Pressure Transducer
transducers
Cardiovascular
An extremely versatile and accurate
pressure transducer
• Simple to use and robust
• Transducer and Amplifier in a single compact unit
• BNC output for connection to virtually any data
acquisition system
The RGBP transducer converts picofarad changes of capacitance into highlevel DC voltages using a unique electronic circuit (U.S. Patent #4,142,144).
This circuit is extremely sensitive and stable, producing a signal suitable for
direct connection to recorders, oscillographs and computers.
The transducer amplifier has a 3-digit back lit LCD display that reads directly
in mmHg up to 999. Amplifiers can be stacked for multiple use. It is possible
on special order to have as many as 4 amplifiers operated by one
transformer.
Specifications
Output Voltage
Factory set at 1.0 V/100 mmHg via BNC
connector; calibrated up to 300 mmHg
Linearity
±1.5% of full scale
Compliance
14 µl displacement /100 mmHg, including
305 mm (12 in) of standard 3 mm (1/8 in) ID
vinyl tubing
Dome Volume
300 µl
Pressure Range
-50 to +300 mmHg
Overload Pressure
3000 mmHg
Zero Offset Control
-50 to +100 mmHg
Natural Frequency
> 500 Hz, dry
Electrical Isolation
> 1 kV
Carrier Frequency
2 MHz
Output Impedance
2 kΩ
Input Liquid Connectors
Dual transparent female Luer lock
Drift
Negligible after 5 min. warm-up
Sterilization of Transducer
Chemical: Alcide, Cidex, etc.
Dimensions:
Transducer, H x W x D
43 x 30 x 55 mm (1-1/2 x 1-1/8 x 2-1/4 in)
Handle, OD x L
9.7 x 76.2 mm (3/8 x 3 in)
Amplifier, H x W x D
51 x 95 x 86 mm (2 x 3-3/4 x 3-3/8 in)
Display
LCD, 7.6 mm (0.3 in) high numbers
Weight
908 g (2 lb)
Order #
Product
PY2 72-4496 Research Blood Pressure Transducer, 115 VAC, 60 Hz
PY2 72-4497 Research Blood Pressure Transducer, 230 VAC, 50 Hz
PY2 72-4498 Replacement Dome, pkg. of 1
(Older units require retrofit)
The RGBP uses a semi-disposable dome of medical grade Silastic® with an
integral silicone rubber diaphragm. Blood only contacts the diaphragm.
Domes are supplied sterile and can be re-sterilized and reused without
affecting calibration. Replacement domes are available as accessories.
Please note that replacement domes listed on this page are for Harvard
Apparatus’ newer model transducer ONLY. The older model is distinguished
by a black threaded ring at the base of the dome. The newer models have a
white ring at the base of the dome. We are no longer able to offer
replacement domes for these older units.
For Catheters, see pages B16 - B21.
J4
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
transducers
APT300 Blood Pressure Transducer
Inexpensive
Reliable
Accurate
Low volume displacement
Suitable for virtually all arterial pressure applications
Easy to fill
Stopcocks included
Simple holder for rod mounting
Replacement APT300 transducer head
Replacement cable with contact plate
It can be used for measurement of arterial pressure in vivo as well as
for perfusion pressures in isolated perfused organs such as heart or
kidney. It can also be used to measure isovolumetric left ventricular (using
a balloon) pressures in isolated hearts from mice up to rabbits or pigs.
Holder for APT300 transducer,
8mm rod, length 160mm
Holder for APT300 transducer,
8mm rod, length 75mm
The transducer consists of a contact plate with cable and the
exchangeable transducer head, which can easily be replaced. Contact
plates with cables for different amplifier types are available.
PY2 73-3862 APT300 Pressure transducer for PLUGSYS TAM Amplifier
The APT300 transducer is an inexpensive pressure transducer which can
be used to measure arterial blood pressures in all species, even on mice
with a high heart rate.
Order #
Cardiovascular
•
•
•
•
•
•
•
•
transducers
Pressure transducer APT300 with 3m cable and connector for
PLUGSYS TAM Amplifier
Product
PY2 73-3863 APT300 Pressure Transducer for Harvard UK
Transducer Interface
PY2 73-3864 APT300 Pressure Transducer for Grass Amplifiers
Specifications
PY2 73-3865 APT300 Pressure Transducer for Gould 6600 Series
Operating pressure
-300 to 300 mmHg
Overpressure
4000 mmHg
Sensitivity
5 µV/V/mmHg (±1%)
Temperature coefficient
< 0.1% / °C
PY2 73-3866 APT300 Pressure transducer for ADInstruments
Bridge Amp
PY2 73-3878 APT300 Pressure Transducer for
DSI/PONEMAH 7700 Amplifier
Zerodrift
< 0.2 mmHg / °C
Accessories
Zero offset
< 25 mmHg
Excitation voltage
2 – 15 V DC (or AC up to 5kHz)
PY2 73-3860 Replacement Cable with Contact plate for PLUGSYS
TAM Amplifier
Isolation against fluid
> 5000 V
PY2 73-3861 Replacement APT300 Transducer Head
Operating temperature
15° to 40°C
PY2 73-3868 Holder for APT300 Transducer, 8mm Rod, Length 160mm
Storage temperature
-25° to 70°C
PY2 73-3869 Holder for APT300 Transducer, 8mm Rod, Length 75mm
Volume displacement
< 0.04 mm 3/100 mmHg
PY2 73-0566 Perspex Block Clamp to Mount Transducer on a Rod
Output impedance
356 Ohm ±1%
PY2 73-0500 Stand with Block Clamp
Frequency response
> 1 KHz
Cable length
3m
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
J5
transducers
P75 Venous Pressure Transducer
Blood Pressure Transducer P75
Specifications
Pressure Range
±75 mmHg (±100 cmH2O)
Volume Displacement
0.06 mm3 /10 mmHg
Linearity
±0.15 mmHg
Long-Term Drift
±0.04 mmHg
Overload
-760 (= vacuum) to 4000 mmHg
Measurement Media
All gases and liquids which do not attack Macrolon®
Temperature Range
0° to 50°C
Zero Drift
±0.04 mmHg/10°C (0° to 50°C)
Range Drift
±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)
Electrical Data:
transducers
Supply Voltage
5 V (4.5 to 5.5 V) DC only
Current Loading
15 mA max.
Sensitivity
Frequency Range
300 Ω, nominal
Connection Cable
Approx. 1.5 m (4.9 ft) long
1 mV/mmHg, nominal
Output Resistance
Cardiovascular
• For low pressure applications with liquids and
gasses ±75mmHg
• Excellent sensitivity and baseline stability
• Applications include:
– Venous blood pressure
– Esophageal pressure with fluid
filled catheter
– Perfusion pressure in isolated lung and liver
– Perfusion pressure on perfused hollow
organs like the esophagus
• Robust construction, easy to fill, bubble free
The P75 has a removable Macrolon® dome with a pressure connection and
a vent connection at the side, so that it can be filled free of air bubbles.
The dome connections have a male Luer taper so that suitable stopcocks*
can be attached. The transducer has a metal housing. The actual pressure
sensor inside is made from ceramic and therefore has excellent resistance
to different media. The transducer’s rugged construction can withstand
pressure overloads up to 4000 mmHg without damage. It works together
with any DC bridge amplifier (e.g., PLUGSYS TAM-A). See the Physiology
Section I.
0 to 100 Hz
Suitable Amplifiers Any bridge amp providing 5V DC excitation voltage
Mechanical Data:
Pressure
Connections
Luer taper, male
Weight
0.35 kg (0.8 lb)
Dimensions,
HxWxD
40 x 40 x 35 mm (1.57 x 1.57 x 1.38 in)
Mounting Rod,
OD x L
8 x 70 mm (0.31 x 2.76 in)
Order #
Product
PY2 73-0020 Blood Pressure Transducer P75 for
PLUGSYS TAM Amplifier
PY2 73-0021 Blood Pressure Transducer P75 for
Harvard Apparatus Transducer Interface
PY2 73-0022 Blood Pressure Transducer P75 for Grass Amplifiers
PY2 73-0023 Blood Pressure Transducer P75 for Gould 6600 Series
PY2 73-0024 Blood Pressure Transducer P75 for Gould 4600 Series
PY2 73-0025 Replacement Dome for Venous Blood Pressure
PY2 73-3738 Blood Pressure Transducer P75 for
ADInstruments Bridge Amp
*Use one each of PY2 73-0096 three-way stopcock and PY2 73-0097 one-way stopcock
J6
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
transducers
Isolated Physiologic Pressure Transducers
Specifications (continued)
• Ideal for measuring pressure from venous
through atrial ranges
• Available in P23XL standard or P10EZ
miniature size
• For use with:
– Harvard Apparatus UK amplifiers
– PLUGSYS modules
– Grass amplifiers
– Protocol propac monitor
– Gould electronic 6600 and 4600 series
of amplifiers
±1.5 mmHg/0 to 30 mmHg
Hysteresis
±0.1 mmHg/0 to 10 mmHg
Cable Length
3.7 m (12 ft)
Operating Temperature
20° to 40°C (68° to 104°F)
Weight (Without Cable):
Standard P23XL
15 g (1.46 oz)
Miniature P10EZ
5 g (0.18 oz)
Length (Including Dome):
Standard P23XL
40 mm (1.58 in)
Miniature P10EZ
37 mm (1.46 in)
Isolated Physiologic Pressure Transducer
Transducer with Interface Cable
Amplifier
Standard
P23XL
Miniature
P10EZ
Interface
Cable Only
Harvard Apparatus
PY2 72-2461
PY2 72-2466
PY2 60-0298
HA-HSE
PY2 72-2880
PY2 72-2881
PY2 72-2882
Grass
PY2 72-2462
PY2 72-2467
PY2 60-0300
Propac
PY2 72-2463
PY2 72-2468
PY2 60-0297
These solid state isolated pressure transducers measure from -50 to +300
mmHg with a 100 mmHg shunt cal resistor. Safety is assured by an
isolated sensing mechanism and plastic case. They are defibrillator
protected. Select the transducer based on your required size, pressure and
equipment to be used. Domes and interface cables must be
purchased separately.
Gould 4600
PY2 72-2464
PY2 72-2469
PY2 60-0299
Gould 6600
PY2 72-2465
PY2 72-2470
PY2 60-0296
Transducer interface cables with integral connector are also sold
separately. This permits the same transducer to be connected to different
equipment. Simply purchase the necessary interface cable based on the
equipment you will be using. The cable is 3.7 m (12 ft) long with a mating
connector for instrument specified. Replacement reusable polycarbonate
domes are available separately. They are supplied individually non-sterile
(may be sterilized a limited number of times). Disposable diaphragm
domes are also available and are supplied in a box of 12,
individually packaged.
PY2 60-0281 P10EZ Pressure Transducer without Connection Cable
(Domes Ordered Separately, see below)
Order #
transducers
PY2 60-0281 Miniature
Isolated Physiologic
Pressure Transducer
0.04 mm3/100 mmHg pressure
Non-Linearity
Cardiovascular
PY2 60-0280 Standard
Isolated Physiologic Pressure
Transducer
Volume Displacement
Product
PY2 60-0280 P23XL Pressure Transducer without Connection Cable
(Domes Ordered Separately, see below)
PY2 72-2883 Interface Cable, Universal Connector to Tinned Leads
(no connector), for Use with Other Equipment, Mating
Connector Required
PY2 60-0283 Reusable Polycarbonate Dome for P10EZ Miniature,
Luer Lock Fitting, pkg. of 1
PY2 60-0294 Disposable Diaphragm Dome for P10EZ Miniature,
Rotating Luer Lock Fitting, pkg. of 12
PY2 60-0290 Reusable Polycarbonate Dome for P23XL Standard Size,
Linden Fitting, pkg. of 1
Specifications
Pressure Range
-50 to +300 mmHg
Over-Pressure Tolerance
10,000 mmHg
PY2 60-0292 Disposable Diaphragm Dome for P23XL Standard Size,
Rotating Luer Lock Fitting, pkg. of 12
PY2 60-0293 Disposable Diaphragm Dome for P23XL Standard Size,
Standard Linden Fitting, pkg. of 12
Bridge Resistance:
Input Resistance
1,000 W, nominal
Output Resistance
350 W, nominal
Excitation Voltage
Up to 10 VAC or DC rms max., up to 5 kHz
Zero Offset
±40 mmHg, max.
Sensitivity
5 µV/V mmHg ±1%
Thermal Coefficient:
Of Sensitivity
±0.1 %/°C
Of Zero
±0.3 mmHg/°C
Electrical Leakage
> 2 µA at 120 VAC, 60 Hz
Defibrillator Withstand
400 watt-seconds, max. across 50 W load
For Isometric and Isotonic Transducers,
see Physiology Section I.
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
J7
transducers
TRA Series Blood Pressure Transducers
transducers
Cardiovascular
Reusable Pressure Transducer TRA021
Disposable Pressure Transducer TRA023
The Harvard Apparatus Research TRA021 is an economical, reusable blood
pressure transducer suitable for routine laboratory arterial and venous
blood pressure measurements. The rugged construction and dome-type
design makes the TRA 021 a good general use blood pressure transducer.
The Harvard Apparatus Research TRA023 is a disposable alternative to
the TRA021, reusable blood pressure transducer. Suitable for most arterial
and venous blood pressure measurements, the in-line design allows lower
cost while maintaining measurement accuracy.
The TRA021 is designed to work with the ISO 510 Amplifier System, see
the Physiology Section I, however custom connectors are available upon
request. The Transducer is supplied with instruction manual and
calibration certificate.
The TRA023 is designed to work with the ISO 510 Amplifier System, see
the Physiology Section I, however custom connectors are available upon
request. The Transducer is supplied with instruction manual and
calibration certificate.
Specifications
Specifications
Range
-50 to 300 mmHg
Sensitivity
4 µV/V/mmHg
Bridge Resistance
350 W
Excitation Voltage
5 to 10 VDC
Volume Displacement
0.05 mm3/100 mmHg
Total Volume
0.25 ml
Weight
85 g
Size
18 x 24 x 74 mm
Order #
Model
PY2 76-0411 TRA021
J8
Range
-50 to 300 mmHg
Sensitivity
5 µV/V/mmHg
Excitation Voltage
2 to 5 VDC
Operating Life
> 500 hrs
Order #
Model
PY2 76-0326 TRA023
Product
Disposable Research Pressure Transducer
Product
Reusable Research Pressure Transducer
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
transducers
Electronic Pressure Calibrators
The built-in pressure meter measures the set pressure accurately and
indicates it in digital form. Since the generated pressure is identical at the
built-in pressure meter and at the test object, the pressure measured by the
test object corresponds exactly to the pressure indicated by the KAL 84.
Electronic Pressure Calibrators
Models with different pressure ranges are available. Each model has an
application-specific range (range 1) and can be switched to a
corresponding SI range (range 2) in Pascal (Pa) or Kilopascal (kPA).
The calibrator KAL 84 is used for calibrating pressure sensors. It represents a
combination of a pressure generator (hand pump) and a pressure meter with
digital display. The instrument provides a simple means for testing and
calibrating both pressure sensors and complete pressure measuring equipment.
High accuracy and excellent reproducibility together with an especially
rugged construction provide the unit with all the properties required for
laboratory applications.
After the unit has been switched on and connected to the pressure sensor to be
calibrated (test object), the required pressure is set with the small hand-wheel.
Measurement and calibration range for appropriate
model (see table below)
Linearity
±0.5% FS ±1 digit for mercury models, ±1% FS ±1 digit
for water models
Hysteresis
0.1% FS
Overpressure Limit
200% FS for mercury models 500% FS
for water models
Response Time
TE = 20 ms, time constant can be switched to 0.1 sec
or 1 sec
Analog Output
0 to 1 V for 100% nominal range, load resistance at
least 2 kΩ
Temperature Range:
Nominal
+10°C to +50°C
Operating
0°C to +60°C
Pressure Connections
6.5 mm OD for 5 mm ID tubing
Power Supply
9 V rechargeable battery, mains adapter
Dimensions, H x W x D
100 x 260 x 180 mm (3.9 x 10.2 x 7.1 in)
Weight
Approx. 3 kg (6.6 lb)
Optional Certificate
Linearity test certificate, DKD (German calibration
service, see below)
Order #
Cardiovascular
• Maintenance free precision pressure generation
• 4 units available:
– 0 to 200 mmHg
– 0 to 300 mmHg
– 0 to 20 mmH2O
– 0 to 200 mmH2O
• Calibration certificate on request
Range
transducers
Specifications
Product
PY2 73-0977 Calibration Certificate with KAL84 Purchase
PY2 73-2918 Recalibration of KAL84 with Certificate
(Requires Return of Unit)
Electronic Pressure Calibrators
115 VAC, 60 Hz
230 VAC, 50 Hz
Model
Liquid
Range 1
Range 2
Used for Calibration of:
PY2 73-0012
PY2 73-0013
KAL 84 H
Mercury
0 to 199.9 mmHg
0 to 26.66 kPa
Blood Pressure Transducers
PY2 73-0014
PY2 73-0015
KAL 84 SH
Mercury
0 to 300.0 mmHg
0 to 39.99 kPa
Blood Pressure Transducers
PY2 73-0016
PY2 73-0017
KAL 84 L
Water
0 to 19.99 mmH2O
0 to 196.0 Pa
Low-Range Differential Pressure Transducers
PY2 73-0018
PY2 73-0019
KAL 84 M
Water
0 to 199.9 mmH2O
0 to 1960 Pa
Low-Range Differential Pressure Transducers
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
J9
transducers
NEW Millar MPVS Ultra Pressure-Volume Systems
MPVS Ultra Hardware
transducers
The MPVS Ultra simultaneously and continuously measures high-fidelity
left ventricular pressure and relative volume from the intact beating hearts
of animals ranging in size from transgenic mice to domestic livestock.
Cardiovascular
Using the MPVS Ultra, cardiovascular pressure and volume signals can be
plotted against each other in real time, generating the characteristic
pressure-volume (P-V) loops that are an excellent illustration of the
cardiac cycle in normal or diseased conditions of the living heart.
MPVS Ultra is the only complete solution for measuring real-time
cardiovascular pressure and volume in small and large animal models with an
industry-leading seven volume segments.
Millar catheters and hardware integrate seamlessly with Harvard
Apparatus Physiology systems to create a complete Cardiovascular
Physiology solution.
MPVS Ultra Components
• MIKRO-Tip® P-V catheters
• P-V signal conditioning hardware with innovative
software-controlled user interface
• PVAN Ultra™ data analysis software
• Rho cuvette for volume calibration
• Data acquisition system (Choose from
available Harvard Apparatus DAQ
systems in Physiology Section I)
• Connection cables
• Computer (not included)
J10
2F Pressure-Volume Catheter, SPR-838
Features
• Real-time pressure-volume measurement at
the source
• High-frequency response
• No motion artifact or damping of pressure signal
• Minimally invasive
• Small and large animal capabilities
• Software controlled user interface
• Comprehensive, easy-to-use analysis software
Applications
• Baseline P-V loop analysis
• Occlusion P-V loop analysis
• Phenotyping gene manipulations
• Cardiac hypertrophy
• Cardiac failure
• Cardiovascular remodeling
• Toxicology
• Pharmacology (rapid drug screening)
• Cardiac resynchronization therapy
• Surgical interventions
• Ischemia/reperfusion studies
✐
NOTE: Please contact your local Harvard
Apparatus Representative or our Technical
Support Team to configure a system to your
requirements.
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
transducers
NEW Millar MPVS Ultra Pressure-Volume Systems
(continued)
1.4F SPR-839
Enlargement of tips of Pressure-Volume Catheters
Order #
Product
transducers
210F SPR-838
PY2 72-9739
MPVS Ultra Single Segment Unit with Control Interface Software
PY2 72-9834
MPVS Ultra Upgrade (Converts Single Segment Unit to Multi Segment Unit)
MPVS Ultra Multi Segment for all animal models
PY2 72-9724
MPVS Ultra with Control Interface Software
Accessories
PY2 72-9835
Ultra Cable Pack 4 ft (CEC-4E PV Cable, PEC-4D)
PY2 72-9727
Ultra Cable Pack 10 ft (CEC-10E PV Cable, PEC-10D)
PY2 72-9728
BNC Cable Pack-PowerLab (10 BNC-BNC 9 in, 1 BNC-BNC 1 ft, 2 BNC-BNC 3 ft)
PY2 72-9836
BNC Cable Pack-STD. (13 BNC-BNC 3 ft)
PY2 72-9726
RHO CUVETTE w/ Well and Cable as one unit
PY2 72-9725
PVAN Ultra SOFTWARE CD
PY2 72-9837
EPC-10UT - ECG Cable 10 ft unterminated
PY2 72-9838
CEC-4E - PV Extension Cable, 4 ft
PY2 72-9826
PEC-4D - Pressure Extension Cable, Redel - Low Profile 4 ft
PY2 72-9839
CEC-10E - PV Extension Cable, 10 ft
PY2 72-9816
PEC-10D - Pressure Extension Cable - Low Profile 10 ft
✐
Cardiovascular
MPVS Ultra Single Segment for Mouse & Rat use only
NOTE: Please contact your local Harvard
Apparatus Representative or our Technical
Support Team to configure a system to your
requirements.
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
J11
transducers
NEW Millar MIKRO-Tip P-V Catheters
MIKRO-Tip P-V catheters combine pressure sensors and electrodes for simultaneous high-fidelity pressure-volume measurements from a single instrument.
Order #
Model
Product
Single Segment Catheters - Mice, Rats
PY2 72-9740
PVR-1030
1F, 4E 3.0 mm spacing, 4.5 cm, Non-repairable
PY2 72-9722
PVR-1035
1F, 4E 3.5 mm spacing, 4.5 cm, Non-repairable
PY2 72-9721
PVR-1045
1F, 4E 4.5 mm spacing, 4.5 cm, Non-repairable
PY2 72-9723
SPR-839
1.4F, 4E 4.5 mm spacing, 4.5 cm
PY2 72-9738
SPR-839
1.4F, 4E 4.5 mm spacing, 4.5 cm, NO REPAIR
PY2 72-9741
SPR-853
1.4F, 4E, 4.0mm, TAPER
PY2 72-9742
SPR-848
1.4F, 4E 4.5 mm spacing, Dual sensor, APICAL
PY2 72-9743
SPR-864
1.4F, 4E 4.5 mm spacing, Dual sensor, CAROTID
PY2 72-9744
SPR-847
1.4F, 4E 9.0 mm spacing, 15 cm
PY2 72-9745
SPR-869
2F, 4E 6.0 mm spacing, 15 cm
transducers
Cardiovascular
PY2 72-9745NR SPR-869
2F, 4E 6.0 mm spacing, 15 cm, NO REPAIR
PY2 72-9736
SPR-838
2F, 4E 9.0 mm spacing, 15 cm
PY2 72-9737
SPR-838
2F, 4E 9.0 mm spacing, 15 cm, NO REPAIR
PY2 72-9746
SPR-878
2F, 4E 12.0 mm spacing, 15 cm
PY2 72-9747
SPR-858
2F, 4E 14.0 mm spacing, 15 cm
PY2 72-9748
SPR-901
2F 2P, 4E 9.0 mm spacing, 15 cm, CAROTID
PY2 72-9749
SPR-902
2F 2P, 4E 9.0 mm spacing, 15 cm, APICAL
2F Multi Segment Catheters - Large Rats
PY2 72-9750
SPR-931
2F, Single Field, 6E 3.0mm spacing, Straight, 12.5 cm
PY2 72-9751
SPR-932
2F, Single Field, 8E 3.0mm spacing, Straight, 12.5 cm
3F Multi Segment Catheters - Rabbits/Cats
PY2 72-9752
SPR-923-1
3F, Single Field, 10E 3.0mm spacing, Straight, 105 cm
PY2 72-9753
SPR-923-3
3F, Single Field, 10E 4.5mm spacing, Straight, 105 cm
PY2 72-9754
SPR-877
3F, 10E Dual Field 2.5 mm spacing, Straight, 120 cm
PY2 72-9755
SPR-855
3F, 10E Dual Field 4.0 mm spacing, Straight, 120 cm
PY2 72-9756
SPR-856
3F, 10E Single Field 4.5 mm spacing, Straight, 120 cm
PY2 72-9757
SPR-889
3F, 10E Single Field 3.0 mm spacing, U-Tip, 80 cm
PY2 72-9758
SPR-894
3F, 10E Dual Field 4.0 mm spacing, U-Tip, 80 cm
PY2 72-9759
SPR-845
3F, 8E Single Field 3.0 mm spacing, U-Tip, 120 cm
PY2 72-9760
SSD-1033
3F, 8E Single Field 4.3 mm spacing, U-Tip, 140 cm
5F Multi Segment PV Catheters - Dog/Pig/Sheep
PY2 72-9761
SPR-550-2
5F, 12E Dual Field 9.0 mm spacing, Pigtail, 125 cm
PY2 72-9762
SPR-550-5
5F, 12E Dual Field 7.0 mm spacing, Pigtail, 125 cm
PY2 72-9763
SPR-550-7
5F, 12E Dual Field 10.0 mm spacing, Pigtail, 125 cm
PY2 72-9764
SPR-550-8
5F, 10E Single Field 7.0 mm spacing, Pigtail, 125 cm
PY2 72-9765
SPR-554-5
5F, 12E Dual Field, 7.0 mm spacing, Straight, 125 cm
PY2 72-9766
SPR-554-11
5F, 10E Dual Field, 7.0 mm spacing, Straight, 125 cm
PY2 72-9767
SPR-560-1
5F, 12E Dual Field, 7.0 mm spacing, Pigtail, 125 cm
PY2 72-9729
SPR-562-1
6F 2P, 12E Dual Field 7.0 mm spacing, Pigtail 125 cm
PY2 72-9769
SPR-570-2
7F, 12E Dual Field, 9 mm spacing, Pigtail 125 cm
PY2 72-9770
SPR-570-7
7F, 12E Dual Field, 10 mm spacing, Pigtail 125 cm
PY2 72-9771
SPR-570-9
7F, 8E Single Field, 8.5 mm spacing, Pigtail 125 cm
PY2 72-9772
SPR-572-7
7F, 12E Dual Field, 10 mm spacing, Pigtail 125 cm
RAT/MOUSE SELECTABLE SEGMENT - For use with MPVS-300/400 only
J12
PY2 72-9768
SPR-819
1.4F, 6E, 9.0 mm/14.0 mm
PY2 72-9773
SPR-866
1.4F, 6E, 4.0 mm/6.0 mm
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
transducers
NEW Millar MIKRO-Tip and Ultra Miniature
Pressure Catheters
Millar pressure catheters continue to represent the gold-standard for high-fidelity
pressure measurements for both systemic and intraventricular applications.
2F Pressure Catheter SPR-407
Order #
Model
Product
Pressure Catheters
SPR-671
PY2 72-9779NR SPR-671
PY2 72-9775
SPR-407
1F, Single pressure, 20 cm, Straight, Non-repairable
1.4F Single pressure,1.1F-2F body 15cm from tip, 65 cm
1.4F Single pressure,1.1F-2F body 15cm from tip, 65 cm, NO REPAIR
2F Sensor, 1.5F Body, Single Pressure, 140 cm, Straight
PY2 72-9775NR SPR-407
2F Sensor, 1.5F Body, Single Pressure, 140 cm, Straight, NO REPAIR
PY2 72-9776
SPR-513
2F Sensor, 1.5F body, 140 cm, Angled 5mm from tip
PY2 72-9783
SPR-320
2F Single pressure, 140 cm, Straight
PY2 72-9783NR SPR-320
2F Single pressure, 140 cm, Straight, NO REPAIR
PY2 72-9774
SPR-249A
3F Single pressure, 60 cm, Straight
PY2 72-9778
SPR-595
3F Single pressure, 60cm, Angled
PY2 72-9780
SPR-882
3F Single pressure, 140 cm, Straight
PY2 72-9784
SPR-330A
3F Single pressure, 130 cm, Straight
PY2 72-9777
SPR-524
3.5F Single pressure, 100 cm, Straight, Non-repairable
PY2 72-9785
SPR-340
4F Single pressure, 120 cm, Curved
PY2 72-9786
SPR-340S
4F Single pressure, 120 cm, Straight
PY2 72-9782
MPR-500
5F Single pressure, 70 cm, Non-repairable
PY2 72-9787
SPR-350
5F Single pressure, 120 cm, Curved
PY2 72-9788
SPR-350S
5F Single pressure, 120 cm, Straight
PY2 72-9793
SPR-450
5F Single pressure w/ Lumen,120 cm, Curved
PY2 72-9794
SPR-450S
5F Single pressure w/ Lumen,120 cm, Straight
PY2 72-9789
SPR-360
6F Single pressure, 120 cm, Curved
PY2 72-9790
SPR-360S
6F Single pressure, 120 cm, Straight
PY2 72-9791
SPR-370
7F Single pressure, 120 cm, Curved
PY2 72-9792
SPR-370S
7F Single pressure, 120 cm, Straight
PY2 72-9795
SPR-470
7F Single pressure w/ Lumen,120 cm, Curved
PY2 72-9796
SPR-471A
7F Single pressure, Injection lumen, 115cm, Straight
PY2 72-9797
SPR-474A
7F Single pressure, Injection lumen, Pigtail, 120 cm, Straight
PY2 72-9798
SPR-721
2.5F Dual pressure, 135 cm, Straight
PY2 72-9799
SPR-780C
8F Dual sensor, Pigtail, 120 cm, Straight
PY2 72-9800
SPR-784A
8.5F Dual sensor, Pigtail, 120 cm, Straight
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
transducers
SPR-1000
PY2 72-9779
Cardiovascular
PY2 72-9781
J13
transducers
NEW Millar Electrophysiology Catheters
and Adapter Cables
Amplifier Cables and Adapters
Millar Electrophsiology Catheters
Adapters and cables are available to connect catheters directly to the
range of Harvard Apparatus pressure amplifiers.
Millar electrophysiology catheters utilize tried and true construction to
provide a reliable and minimally invasive way to measure intra-cardiac
electrical activity.
Order #
Adaptor cables are available to connect catheters directly to the range of
Harvard Apparatus Biopotential amplifiers. Call for pricing and availability.
Product
PY2 72-9842 HEC-10C
Pressure Catheter with Viking Connector
to PLUGSYS TAM Amplifier
PY2 72-9843 HEC-10D
Pressure Catheter with Low Profile
Connector to PLUGSYS TAM Amplifier
Order #
Model
Product
PY2 72-9801 EPR-800
1.1F, 8E Gold, 1.0 mm Spacing,
4.5 cm, Redel
transducers
Cardiovascular
PY2 72-9734 AEC-10D
Pressure Catheter with Low Profile
Connector to ADInstruments Bridge Amp
PY2 72-9802 EPR-801
PY2 72-9844 AEC-10C
Pressure Catheter with Viking Connector
to ADInstruments Bridge Amp
1.1F, 8E Gold, 1.0 mm Spacing,
Injection Lumen, 4.5 cm, Redel
PY2 72-9803 EPR-802
PY2 72-9810 TC-510
9pin D-sub Control Unit, Interface Cable
Required
1.6F, 8E gold, 1.0 mm Spacing,
12.5 cm, Redel
PY2 72-9804 EPE-3A
PY2 72-9841
Cable, TC-510 to PLUGSYS TAM Amplifier
3 ft cable, Redel-Redel,
Interfaces with STG Units
PY2 72-9811 TEC-5C
5 ft Cable, Viking Connector to TC-510 Unit
PY2 72-9805 STG-3004
PY2 72-9812 TEC-10C
Unit
10 ft Cable, Viking Connector to TC-510
4 Channel Stimulation,
8 Amplification, 8 Analog Input
PY2 72-9806 STG-3008
PY2 72-9813 TEC-10D
10 ft Cable, Low Profile Connector
to TC-510 Unit
8 Channel Stimulation,
8 Amplification, 8 Analog Output
PY2 72-9807 EP Grounding Kit
Cable set
PY2 72-9814 PCU-2000
CE marked, patient isolated, line powered
dual & single pressure
PY2 72-9808 EPC-5A Cable
5 ft Cable, Redel 14-pin connector
PY2 72-9809 EPC-5UT Cable
5 ft Cable, Redel 14-pin connector
unterminated
PY2 72-9815 PEC-10C
10 ft Cable, Viking Connector
to PCU-2000 Unit
PY2 72-9816 PEC-10D
10 ft Cable, Low Profile
Connector to PCU-2000 Unit
PY2 72-9817 BNC-BNC
Cable
PY2 72-9818 BNC-Phono
Adapter
PY2 72-9819 SD-778
10 ft P-V Catheter Electrodes
to CD Leycom Sigma 5 Unit
PY2 72-9731 SD-797
Connects TC-510 to ADInstruments
Bridge Amp ML110, 112, 118
PY2 72-9732 SD-810
Reversing Cable, Apical approach
PV Catheters to CD Leycom
✐
J14
Model
NOTE: Don’t see an adapter to your
amplifier? Contact technical support for a
custom adapter.
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
transducers
View of the catheter: the catheter (blue) on the right of the handle has a length of
110cm and a diameter of 7F (2.33mm). At the end of the catheter the light blue 90°
stearable part of the catheter is visible. The distal white end tip includes 4 electrodes.
For intraventricular MAP recording
For pacing
Accurate
Steerable unidirectional up to 90° curve
This new combination catheter is used for in-vivo studies in anesthetized
dogs or pigs. The handle allows to curve unidirectionaly up to 90° the
steerable end of the catheter to place the tip optimally inside the
ventricle on the heart wall. The two stimulation electrodes allow pacing
and the recording electrodes to record the intraventricular MAP.
Specifications
Cardiovascular
•
•
•
•
transducers
NEW Combination Catheter MAP-Stimulation 7F
View of the curved (unidirectional
stearable catheter end. (the MAPand the Reference- electrode are
visible
Schematic representation of the
distal tip. (shows also the coding
colors to the cable connection)
MAP Electrode
Central, axial Ag/AgCl MAP-electrode, D=1.5 mm,
protruding by 1mm (Yellow connecting line)
Order #
Reference Electrode
Lateral Ag/AgCl Reference electrode, D=1 mm, 5 mm
proximal to the tip (Blue connecting line)
PY2 73-3872 Combination Catheter MAP-Stimulation
7F for in-vivo studies
Stimulation Electrodes
2 lateral opposite Ag Stimulation electrodes,
D=1 mm, 3 mm proximal to the tip (Green and Red
connecting lines)
Catheter Size
7F (2.33 mm, 0.091 in)
Catheter Length
110 cm (43.31 in)
Catheter Feature
Stearable, 90° Curve, Unidirectional
Connectors
2 mm Banana Male Connectors
Cable Length
60 cm (23.62 in)
Product
PY2 73-3356 Input Cable with 2mm Sockets for BPA
(for MAP electrodes)
PY2 73-3985 Bipolar Connecting Cable 4mm banana male
to 2mm socket, length 2m (for Stimulation electrodes)
Harvard Apparatus • phone 508.893.8999 • toll free U.S. 800.272.2775 • fax 508.429.5732 • www.harvardapparatus.com
J15