OEM Equipment Electrical Apparatus  800-45 600 A 15 and 25 kV Class Deadbreak Apparatus Bushing GENERAL Cooper Power Systems 600 A 15 and 25 kV Class deadbreak apparatus bushing meets the full requirements of IEEE Std 386™ standard separable insulated connector systems. All 600 A separable connectors manufactured according to IEEE Std 386™ standard will operate with this bushing. The epoxy bushings are designed for sidewall mounting in transformers, switches and other apparatus filled with transformer oil or Envirotemp™ FR3™ Fluid or an approved equivalent. Separable connector systems, such as Cooper Power Systems Bol-T™ and T-OP II™ Deadbreak Connectors as well as other similar systems on the market, can be used with these bushings. INSTALLATION No special tools are required. The bushing is mounted through the apparatus sidewall and clamped externally. Refer to In­stal­la­tion Instruction Sheet S800-35-1 (5000050608) for details. PRODUCTION TESTS Tests are conducted in accordance with IEEE Std 386™ standard. n AC 60 Hz 1 Minute Withstand— 40 kV n Minimum Corona Voltage Level— 19 kV Tests are conducted in accordance with Cooper Power Systems requirements: n Physical Inspection n Periodic Dissection n Periodic Fluoroscopic Analysis (X-ray) 0812 • Supersedes 0408 Figure 1. 600 A 15 and 25 kV Class Deadbreak Apparatus Bushing. TABLE 1 Voltage Ratings and Characteristics TABLE 2 Current Ratings and Characteristics Description kV Description Amperes Standard Voltage Class 25 Continuous Maximum Rating Phase-to-Ground 15.2 Short Time ac 60 Hz 1 Minute Withstand 40 dc 15 Minute Withstand 78 600 A rms (Aluminum) 900 A (Copper) 25,000 A rms symmetrical for 0.17 s 10,000 A rms symmetrical for 3.0 s BIL and Full Wave Crest 125 Minimum Corona Voltage Level 19 Current ratings and characteristics are in accordance with IEEE Std 386™ standard. Voltage ratings and characteristics are in accordance with IEEE Std 386™ standard. 1 600 A 15 and 25 kV Class Deadbreak Apparatus Bushing 4.93 (125.2 mm) 4.69 (119.1 mm) .75 (19.1 mm) 1.36 MAX (34.5 mm) 5/8-11 UNC 2A THREAD 1.25 (31.8 mm) Ø 2.56 (65 mm) 4.00 (101.6 mm) 5/8-11 UNC-2A THREAD “OPTIONAL” REMOVABLE STUD BLACK MOLDED GROUND SHIELD Allows fully shielded connection. Figure 2. 600 A 15 and 25 kV Class Deadbreak Apparatus Bushing. NOTE: Dimensions given are for reference only. ordering information To order a 600 A 15 and 25 kV Class deadbreak bushing, specify bushing, clamp and gasket from Table 3. TABLE 3 Bushing, Clamp and Gasket Description Catalog Number 15 and 25 kV Bushing Aluminum Conductor Copper Conductor 2637019B02 2637019B04 Plated Steel Clamp 2637023B01 Stainless Steel Clamp 2637023B02 Gasket 0537980C06 2 TABLE 4 Accessories Description Catalog Number Shipping Cap (not for energized operation) 2637700B02 If a threaded stud is required, specify: Aluminum Copper STUD-A STUD-C NOTE: For other thread types, contact your Cooper Power Systems representative.. TANK WALL OPENING 800-45 mm) 4.50" Sq. (114.3 mm) .38" (9.7 mm) 3.42" (86.9 mm) 1.25" (31.8 mm) 5/8-11 UNC THREAD 2.56" BOTH ENDS 5.0 mm) NK WALL PENING Ø .500" (4 REQD) Ø 3.25" (82.6 mm) Figure 3. Clamp front and side view. NOTE: Dimensions given are for reference only. 5.17" (131.3 mm) 3.75" 5.3 mm) 1.25" (31.8 mm) 5/8-11 UNC THREAD BOTH ENDS 3 600 A 15 and 25 kV Class Deadbreak Apparatus Bushing © 2012 Cooper Industries. All Rights Reserved. Cooper Power Systems, Bol-T and T-OP II are valuable trademarks of Cooper Industries in the U.S. and other countries. You are not permitted to use the Cooper Trademarks without the prior written consent of Cooper Industries. IEEE Std 386™ standard is a trademark of the Institute of Electrical and Electronics Engineers, Inc., (IEEE) This publication/ product is not endorsed or approved by the IEEE. IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers, Inc. Envirotemp™ and FR3™ are licensed trademarks of Cargill, Incorporated. One Cooper | www.cooperpower.com | Online 4 2300 Badger Drive Waukesha, WI 53188 USA