PDF File - Emergency Lighting

advertisement
CATALOG #:
PROJECT:
SURE-LITES
TYPE:
DESCRIPTION
S P E C I F I C AT I O N F E AT U R E S
A long-awaited and needed
system designed for locations
where unobtrusive aesthetics
are of utmost importance. The
housing is fully recessed in dry
wall or grid ceiling installations.
Designer pinchback heads
rotate 358° and swivel 90° to 0°.
Electronic
Maintenance Free, Long Life
Dual Voltage Input 120/277 VAC,
60 Hz
Full Recharge Time,
24 hrs. (max.)
Line-latching
Polarized Battery Terminals
Solid-state Voltage
Limited Charger
Code Compliance
UL 924
Solid-state Switching
Life Safety NFPA 101
Low Voltage Disconnect
Ideal for commercial and
institutional environments
where easy recessed
installation and minimal
maintenance is desired.
NEC/OSHA
Brownout Circuit
Most State and Local Codes
Overload/Short Circuit
Protection
RD SERIES
Warranty
Test Switch/Power
Indicator Light
Unit – 1 year
Housing Construction
Head/Lamp Data
20 Gauge Rough-In Section
Tungsten Halogen Standard
Knockout, Conduit or Cord Set
Two Heads Standard
Hanger Bars, T-Bar Clips
Glare-Free Lens
Single Molex
Electrical Connector
Fully Adjustable
Battery – 5 year pro-rata
SEALED LEAD
C A L C I U M B AT T E R Y
Emergency Lighting
Remote Capability
White Finish
Injection Molded
Thermoplastic
Battery
Sealed Lead Calcium,
Recombination
Matches Housing Finish
3 1/2"
[89mm]
6 1/4" [159mm]
9 1/4" [235mm]
7" max.
[178mm]
5 1/8" [130mm]
10 1/4" [260mm]
12 7/8" [327mm]
E L E C T R I C A L R AT I N G S
E N E R G Y D AT A
R a t e d W a t t a g e to 87 1/2% of Rated D.C. Voltage
Model
DC Voltage
1 1/2 Hours
RD-1
RD-3
6
6
18
27
2 Hours
15
24
3 Hours
10
18
Lamp Information
4 Hours
8
14
Type
Wattage
Number
Tungsten Halogen
Tungsten Halogen
6
12
29-12
29-66
Input Current (Max.):
120V= .12A
277V= .05A
O R D E R I N G I N F O R M AT I O N
SAMPLE NUMBER: RD-1-V
O p t i o n s (add as suffix)
Model Number
RD-1
RD-3
A c c e s s o r i e s (order separately)
A*=Ammeter
WG-2=Wire Guard
SD=Self-Diagnostics
VS=Choose polycarbonate vandal shield
desired from accessories sheet
TDM=Time Delay Monitor
V*=Voltmeter
Other Options: Consult Factory
*Provision for one meter only.
COOPER LIGHTING
ADV990151
®
R D SERIES
PHOTOMETRICS
Horizontal Distribution
Ve r t i c a l D i s t r i b u t i o n
10
FEET
LEFT
10
FEET
LEFT
1FC
0
0.5
0.3
0.2
0.1
LAMP
AXIS
FEET
RIGHT
10
0
10
20
30
40
50
60
1FC
0
70
0.3
0.2
0.1
LAMP
AXIS
FEET
RIGHT
10
0
10
FEET FROM LAMP (Measured on axis)
20
30
40
50
60
70
LAMP
AXIS
0.1
FEET FROM LAMP (Measured on axis)
Lamp No. 29-12
15
FEET
LEFT
0
FEET
RIGHT
15
0.5
Lamp No. 29-12
15
FEET
LEFT
1FC
0
10
20
30
0.5
40
50
0.3
0.2
60
70
LAMP
AXIS
80
90
0.1
100
0
FEET
RIGHT
15
1FC
0
10
40
0.3
50
60
0.2
70
80
90
100
FEET FROM LAMP (Measured on axis)
FEET FROM LAMP (Measured on axis)
Lamp No. 29-66
Initial Lumens – 29-12 @ 113
29-66 @ 302
30
20
0.5
Lamp No. 29-66
T E C H N I C A L D AT A
Heads
Line-Latched
Brownout Circuit
The lamp housing is constructed
of injection molded
thermoplastic with high
gloss opaque white finish.
The three dimensional
permanently tensioned swivel
assembly permits 80° aiming
adjustment from vertical and
approximately 358° rotation.
The pinchback design features
a R18 size aperture with
removable matte black baffle.
Sure-Lites’ line-latched electronic
circuitry makes installation easy
and economical. A labor efficient
AC-activated load switch
prevents battery discharge
during installation to a nonenergized circuit. Line-latching
eliminates the need for a
contractor’s return to a job
site to reconnect the batteries
when the building’s main power
is permanently turned on.
The brownout circuit in SureLites’ units monitors the flow
of AC current to the unit and
activates the emergency
lighting system when a
predetermined reduction
of AC power occurs. This
dip in voltage will cause most
ballasted fixtures to extinguish
causing loss of normal lighting
even though a total power
failure has not occurred.
Lamps
Solid-State Charger
S o l i d - S t a t e Tr a n s f e r
Designed specifically for
emergency lighting applications,
the R18 size design insures
optimum glare-free light
distribution. Tungsten halogen
lamps maximize light output
with lower wattages.
Supplied with a 120/277 VAC,
voltage regulated solid-state
charger. Immediately upon
restoration of AC current after
a power failure, the charger
provides a high charge rate.
The charge circuit reacts to
the condition of the battery
and alters the rate of charge in
order to maintain peak battery
capacity and maximize battery
life. Solid-state construction
recharges the battery following
a power failure in accordance
with UL 924.
The unit incorporates a solidstate switching transistor which
eliminates corroded and pitted
contacts or mechanical failures
associated with relays. The
switching circuit is designed
to detect a of AC voltage and
automatically energizes the
lamps. Upon restoration of
the AC power, the emergency
lamps will switch off and the
charger will automatically
recharge the battery.
Housing
Corrosion resistant 20 gauge
rough-in section/battery
support installs easily and
comes complete with hanger
bars for installation in plaster
or drywall and accessory
T-bar clips for installation in
suspended grid type ceilings.
Attractively styled 20 gauge
steel face plate is finished with
a white polyester powder coat
paint. Torsion springs and a
single Molex connector make
final installation quick and easy.
Overload and Short
Circuit Protection
The solid-state overload
monitoring device in the DC
circuit disconnects the lamp
load from the battery should
excessive wattage demands
be made and automatically
resets when the overload or
short circuit is removed. This
overload current protective
feature eliminates the need
for fuses or circuit breakers
for the DC load.
L o w Vo l t a g e D i s c o n n e c t
Te s t S w i t c h / P o w e r I n d i c a t o r
Light
Conveniently located Test
Switch allows for manual
verification of proper operation
of the transfer circuit and
emergency lamps. The Power
Indicator Light provides visual
assurance that the AC power
is on.
Sealed Lead Calcium Battery
The fully sealed, long life,
maintenance free lead calcium
battery is ideal for emergency
lighting applications. These
recombinant cycle batteries
typically provide eight to ten
years of life and may be
operated in any position.
Warranty
All Sure-Lites’ units are backed
by a firm one year warranty
against defect in material and
workmanship (excluding
lamps). Maintenance free,
long life, sealed lead calcium
batteries carry a five-year
pro-rata warranty.
When the battery’s terminal
voltage falls below 80% of
the rated voltage, the low
voltage circuitry disconnects
the lighting load. The
disconnect remains in effect
until normal utility power is
restored, preventing deep
battery discharge.
N O T E S : See option/accessories or technical sections for additional detailed product data. Specifications and Dimensions subject to change without notice.
Customer First Center 1121 Highway 74 South, Peachtree City, GA 30269 770.486.4800 Fax 770.486.4801
ADV990151
Download