INVOS™ OxyAlert™ NIRSensor Specifications INVOS™ OxyAlert™ NIRSensors for infants and neonates are used with the INVOS™ cerebral/somatic oximeter to generate continuous, noninvasive readings of regional blood oxygen levels in up to four site-specific areas chosen by the care team. INVOS OxyAlert NIRSensors are applied to the skin’s surface, and are user and patient-friendly, making monitoring of ischemic threats to the brain and body safe and easy. By reporting venous-weighted regional hemoglobin oxygen saturation (rSO2) in tissue directly beneath the sensor, readings reflect the hemoglobin bound oxygen remaining after tissues have taken what they need. Decreases in this venous reserve indicate increased ischemic risk and compromised tissue perfusion, so the care team can assess and intervene accordingly. product specifications Ordering Information OxyAlert™ NIRSensor - Infant/Neonatal Model CNN/SNN Part Number: CNN/SNN Physical Disposable OxyAlert NIRSensor, infant/neonatal Sensor Dimensions 2.72” (6.9 cm) length x 0.97” (2.5 cm) width Depth (Thickness) 0.1005” (2.55 mm) Weight (<5 kg) with sensor cable, supplied 10 per box. Specifications subject to change without notice. 1.1 oz (31g) Sensor Cable Length 5 feet (1.5 m) Patient Adhesive Hydrocolloid (medical grade) Operational Calibration Precalibrated; no need for user calibration Safety Class Continuous Operation Type BF Class I environmental requirements Operating Temperature Humidity Altitude 60ºF – 106ºF (16ºC – 41ºC) 20% – 80% relative humidity, non-condensing To 10,000 feet (3,048 m) Storage Temperature Humidity -4ºF – 110ºF (-20ºC – 45ºC) 20% – 80% relative humidity, non-condensing The noninvasive INVOS 5100C is intended for use as an adjunct monitor of regional hemoglobin oxygen saturation of blood in the brain or in other tissue beneath the sensor. It is intended for use in individuals greater than 2.5 kg at risk for reduced-flow or no-flow ischemic states. It is also intended for use as an adjunct trend monitor of regional hemoglobin oxygen saturation of blood in the brain or in other tissue beneath the sensor in any individual. COVIDIEN, COVIDIEN with logo, Covidien logo and positive results for life are U.S. and internationally registered trademarks of Covidien AG. Other brands are trademarks of a Covidien company. © 2012 Covidien. Currently licensed under Covidien llc with Health Canada. Manufactured by: Covidien llc, 15 Hampshire Street, Mansfield, MA, USA, 02048 CDN-R00138-E Rev. 2012/06 8455 Trans-Canada Highway Saint-Laurent, Quebec H4S 1Z1 877-664-8926 [t] 800-567-1939 [f] www.covidien.com