Protection Earth leakage protection "si" and "SiE" type, A and AC class RCCB-ID 10 mA, 30 mA, 100 mA, 300 mA and 500 mA instantaneous Eu rope 100 mAs, 300 mAs, 500 mAs Function Residual current circuit breakers ensure: b the control and isolation of electrical circuits b the protection of persons against direct and indirect contacts b the protection of installations against insulation faults. They are conform to both the residual current device standard IEC 61008 and to switch standards IEC 60947-1 and IEC 60947-3. Residual current circuit breakers are used in the housing, tertiary and industrial sectors. AC class Trippin is ensured for sinusoidal, alternating currents, whether they be quickly applied or slowly increase. A class Tripping is ensured for sinusoidal, alternating residual currents as well as for pulsed DC residual currents, whether they be quickly applied or slowly increase. Application: loads with electronics, rectifiers, instruments. “si” type Reinforced continuity of supply on disturbed networks with: b a high risk of nuisance tripping: v successive lightning strokes v IT earthing system v variable speed controllers, frequency converters v presence of electronic ballasts v presence of switchgear that incorporates interference filters i.e. lighting, microcomputing, etc. b sources of blinding: v presence of harmonics or high frequency rejection v presence of DC components: diodes, thyristors, triacs v law temperature. “SiE” type The RCCB/ID “SiE” types are particularly suitable for use in humid environments and/or environments polluted by aggressive agents, for example swimming pools, marinas, the food-processing industry, water treatment plants, industrial sites. They also incorporate RCCB/ID “si” functions. Instantaneous It ensures instantaneous tripping (no time-delay). Selective s Total discrimination can be achieved using a non-selective residual current device placed downstream. Description The residual current trip unit is electromechanical. It functions without an auxiliary source. Technical data b Voltage rating: v 230…400 V AC, -15…+10 %. b Frequency rating: v AC and A classes: 50/60 Hz v “si” and “SiE” types: 50 Hz. b Current rating (Ith) at 40 °C: 16…100 A. b As in IEC 61008: v breaking and making capacity: - rated residual (IDm): 2.5 kA - rated (Im): 1.5 kA. b As in IEC 60947-3: v isolation with positive break indication, opening is indicated by a green strip on the device operating handle. This indicator shows that all poles are open. v rated impulse withstand v voltage (Uimp): 6 kV v insulation voltage (Ui): 440 V v utilization category: - AC 23A rating y 63 A - AC 22B ratings 80 and 100 A v padlocking in the “tripped” position is possible using the padlocking device (not supplied) (see page 91903/2). version: 5.3 90134E.indd Protection Earth leakage protection "si" and "SiE" type, A and AC class RCCB-ID 10 mA, 30 mA, 100 mA, 300 mA and 500 mA instantaneous Eu rope 100 mAs, 300 mAs, 500 mAs b Protected against nuisance tripping due to transient overvoltages (lightning, switchgear operation on the network, etc.). b Impulse withstand level 8/20 µs: v AC and A classes: - 250  for instantaneous - 3 k for s v “si” and “SiE” type: - 3 k for instantaneous - 5 k for s. b Short-circuit current withstand (IDc = Inc): 10 kA with 100 A fuse upstream b Number of operations (O-C): 20 000. b Trip units with fixed sensitivities for all ratings: v instantaneous trip unit v selective trip unit: total vertical selectivity can be achieved using 30 mA residual v current devices placed downstream. b Indication: v mechanical: earth fault indication on front panel by means of a mechanical indicator v electrical: using auxiliaries (see page 90142/2). b Remote tripping: using auxiliaries (see page 90142/2). b Environment: v tropicalisation: treatment 2 (relative humidity 95 % at 55 °C) v operating temperature: - AC class: -5…+40 °C - A class, “si” and “SiE” type: -25…+40 °C v storage temperature: -40…+60 °C v weight (g): Type 2P 4P 230 450 b Connection using tunnel terminals for flexible 35 mm2 cable or rigid 50 mm2 cable. b Can be directly connected using comb busbars on 2P residual current circuit breakers when using the P’clic adapter (see page 90150/2). b Conform with standards: v IEC 61008 v IEC 60947-1 v IEC 60947-3. Catalogue numbers AC class RCCB-ID residual current circuit breakers Type 2P N 1 N 2 Voltage (V AC) Rating (A) Sensitivity (mA) Catalogue number width in mod. of 9 mm 230 25 10 30 300 500 30 30 g 100 100 g 300 500 30 300 300 s 500 500 s 30 300 300 s 500 500 s 300 300 s 23008 23009 23011 23012 23014 23072 23015 23073 23016 23017 23018 23021 23028 23022 23029 23020 23030 23032 23026 23033 23034 23035 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 T R 40 63 80 100 90134E.indd version: 5.3 Protection Earth leakage protection "si" and "SiE" type, A and AC class RCCB-ID 10 mA, 30 mA, 100 mA, 300 mA and 500 mA instantaneous E urop 100 mAs, 300 mAs, 500 mAs e Catalogue numbers AC class RCCB-ID residual current circuit breakers (cont.) Type Voltage (V AC) Rating (A) Sensitivity (mA) Catalogue number width in mod. of 9 mm 230/400 25 30 300 500 30 30 g 100 100 g 300 300 s 500 500 s 30 30 g 100 100 g 300 300 s 500 500 s 30 300 300 s 500 500 s 300 300 s 23038 23040 23041 23042 23074 23536 23075 23045 23062 23046 23063 23047 23532 15177 23533 23049 23066 23051 23067 23061 23054 23069 23055 23070 23056 23059 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 10 10 30 300 30 300 300 s 30 300 300 s 500 s 300 s 300 s 23415 23353 23354 23356 23358 23360 23265 23362 23364 23370 23371 23272 23279 4 4 4 4 4 4 4 4 4 4 4 4 4 30 300 500 30 100 100 s 300 300 s 500 30 100 s 300 300 s 500 300 300 s 500 s 300 s 23378 23380 23381 23382 23304 23490 23384 23399 23385 23386 23494 23388 23402 23389 23326 23284 23376 23294 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 4P N 1 3 5 40 T R N 2 4 6 63 80 100 A class RCCB-ID residual current circuit breakers 2P 230 N 1 T 16 25 40 R N 2 63 80 100 4P 230/400 N 1 3 25 5 40 T R N 2 4 6 63 80 100 version: 5.3 90134E.indd Protection Earth leakage protection "si" and "SiE" type, A and AC class RCCB-ID 10 mA, 30 mA, 100 mA, 300 mA and 500 mA instantaneous E urop 100 mAs, 300 mAs, 500 mAs e Catalogue numbers “si” type RCCB-ID residual current circuit breakers Type Voltage (V AC) Rating (A) Sensitivity (mA) Catalogue number width in mod. of 9 mm 230 25 40 63 30 30 30 300 s 300 s 23523 23524 23525 23363 23372 4 4 4 4 4 30 30 30 300 s 30 300 s 23526 23529 23530 23392 23390 23394 8 8 8 8 8 8 2P N 1 T 80 R N 2 N 1 4P 230/400 3 5 T 25 40 63 80 R N 2 4 6 “SiE” type RCCB-ID residual current circuit breakers 2P 230 N 1 25 30 23300 4 40 30 300 s 30 300 s 23307 23314 23352 23355 4 4 4 4 30 30 300 s 30 300 s 23377 23379 23398 23383 23401 8 8 8 8 8 63 T R N 2 N 1 4P 230/400 3 5 25 40 63 T R N 2 4 6 Additional information Dimensions: page 90148/2 Auxiliaries: page 90142/2-90150/2 Accessories: page 91900/2-91903/2 90134E.indd version: 5.3