Data sheet - vossloh

advertisement
LED Street and Outdoor Lighting – IP67 / IP69 / IK08
LED ROADWAY
LIGHT – M-CLASS
SILICONE GEN. 2
IP67 / IP69 / IK08
LED STREET AND OUTDOOR
LIGHTING
WU-M-515
These LED modules are suitable for standard-compliant street lighting,
paths and squares in accordance with EN 13201.
The combination of a robust aluminium base and the enhanced
degree
of protection enables a simpler, modular luminaire design.
The VS ECXd 700/150 W LED driver enables power reduction via
phase inversion.
The modules are available in three white colour tones.
Typical Applications
• Integration in luminaires
• Streetlighting for ME- and S-classes (acc. to EN 13201)
LED Street and
Outdoor Lighting
 DEGREE OF PROTECTION: IP67 / IP69 / IK08
 HIGHLY EFFICIENT: UP TO 151 LM/W
 VERY HOMOGENOUS ILLUMINATION
 INITIAL COLOUR ACCURACY: 5 SDCM
 SURGE PROTECTION: 4 KV
 VDE APPROVED (ACC. TO EN 62031)
pending
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
LED Street and Outdoor Lighting – IP67 / IP69 / IK08
LED Roadway Light
M-Class Silicone
Gen. 2
Technical Notes
• LED built-in module for integration
into luminaires
• 16 high-efficiency High Power LEDs,
serial connected
• ESD protection class 2
• Encapsulated for outdoor applications with
• Surge protection: 4 kV
degree of protection: IP67 / IP69 / IK08
• Weight: 0.32 kg
• Pre-assembled leads: 2 leads: + (white); – (black)
for luminaires of protection class II, length: 500 mm
• Design for optimum thermal management
Electrical Characteristics at tp = 60 °C
Type
No. Voltage DC (V)
of
350 mA
Temperature Power consumption (W)
700 mA
1050 mA
1400 mA
coefficient
LEDs min. typ. max. min. typ. max. min. typ. max. min. typ. max. mV/K
WU-M-515 16
39.4 43.9 45.8 41.5 46
350 mA
700 mA
1050 mA
1400 mA
min. typ. max. min. typ. max. min. typ. max. min. typ. max.
47.9 43.3 47.7 49.7 44.8 49.2 51.2 –44.4
13.8 15.4 16
29.1 32.2 33.5 45.5 50.1 52.2 62.7 68.9 71.7
Use of external LED constant current driver required.
Maximum Ratings
Exceeding the maximum ratings can lead to destruction of the module.
Type
Operation current Operation temperature range at tc point
mA
Storage temperature range
Max. allowed repetitive peak current
°C min.
°C max.
°C min.
°C max.
mA
All types
350
–30
+85
–30
+85
1810
All types
700
–30
+85
–30
+85
1670
All types
1050
–30
+80
–30
+85
1580
All types
1400
–30
+70
–30
+85
1510
Optical Characteristics at tp = 60 °C
Type
Colour
Correlated
Luminous flux* (lm) and typ. efficiency (lm/W)
colour
350 mA
temperature
min.
typ.
typ.
K
lm
lm
lm/W lm
700 mA
min.
CRI** Photo1050 mA
typ.
typ.
min.
lm
lm/W lm
1400 mA
typ.
typ.
min.
lm
lm/W lm
metric
typ.
typ.
lm
lm/W Ra
code
LED-Module_LED-Roadway-Light_M-Class-Silikon_Gen.2_EN – 2/4 – 08/2016
Square - 16 LEDs
–90/+185
2115 2170 141
3995 4105 128
5640 5795 116
7035 7230 105
≥ 70
730/579
–235/+230
2185 2315 151
4135 4380 136
5830 6180 123
7275 7715 112
≥ 70
740/579
5000 –265/+360
1850 2060 134
3550 3900 121
4900 5400 108
6200 6800
≥ 65
650/579
WU-M-515-730
warm white
3000
WU-M-515-740
neutral white 4000
WU-M-515-650
cool white
99
On account of the complex manufacturing process of the modules, the above values only represent statistical variables.
The values do not necessarily correspond exactly to the actual parameters of every single product, which can vary from the typical specification.
* Measurement tolerance of luminous flux: ±7% | ** Measurement tolerance CRI: ±2 | CRI ≥ 80 on request
Operating Life
Modules
Operating life in hours at measured temperature at tp point
IF 350 mA
40 °C
IF 700 mA
60 °C
85°C
40 °C
IF 1050 mA
60 °C
85°C
L80/B10*
> 60,000 > 60,000
46,000 > 60,000 > 60,000 30,000
L70/B10*
> 60,000 > 60,000 > 60,000 > 60,000 > 60,000 58,000
40 °C
IF 1400 mA
60 °C
80°C
50.000 25,000
47,000
27,000
—
> 60,000 > 60,000 48,000
> 60,000
51,000
—
> 60,000
60 °C
80°C
40 °C
These values do not refer to the colour temperature. | * Lxx/Byy (lumen maintenance at xx%, failure rate yy%)
The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
2
LED Street and Outdoor Lighting – IP67 / IP69 / IK08
LED Roadway Light
M-Class Silicone
Gen. 2
Technical Notes
• Dimensions (incl. optics) LxWxH: 120x120x16 mm
• Lenses for street lighting applications of M class
(acc. to EN 13201)
• Optimum illumination – installation ratio: 4.5:1
(distance between luminaire poles to height
of the luminaire pole)
Reference Numbers
Type
Ref. No.
WU-M-515-730
562487
WU-M-515-740
562482
WU-M-515-650
562878
Typical Light Distribution Curve
LED-Module_LED-Roadway-Light_M-Class-Silikon_Gen.2_EN – 3/4 – 08/2016
Mechanical Dimensions
The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
3
LED Street and Outdoor Lighting – IP67 / IP69 / IK08
LED Roadway Light
M-Class Silicone Gen. 2
LED-Module_LED-Roadway-Light_M-Class-Silikon_Gen.2_EN – 4/4 – 08/2016
Assembly and Safety Information
Installation must be carried out under observation of the relevant
regulations and standards. The LED modules are designed for
operation within a casing or luminaire. Safety regulations acc. to
EN 60598 has to be observed. Installation must be carried out in a
voltage-free state (i.e.disconnection from the mains).
• LED built-in modules must not be subjected to any undue
mechanical stress, e. g.:
– handle LED modules carefully
– avoid shear and compressive forces onto
– the optics during handling and installation
– avoid vibrations of more than 2 kHz, 40 G
– Do not carry or move LED modules by using the wires.
• The modules must not be used in hermetically sealed casings.
• The module must be fixed onto a thermally conductive surface with
four M4 screws.
• When installing/screwing the module into a luminaire, please
ensure that the cables are not squeezed between luminaire/heatsink and LED module.
• Safe operation only possible by the use of external constant current
sources (Imax. see table "Electrical Characteristics").
• Operation is dependent on constant current drivers that should
provide the following protective measures:
– short-circuit protection
– overload protection
– overheating protection
• Please ensure the correct polarity of the leads prior to
commissioning. Reversed polarity can destroy the modules.
• The maximum output of the power supply must be observed.
• For optimal load of used constant current driver the modules can
only be connected in series. The quantity of LED modules is limited
by the sum of forward voltage and the capacity of used constant
current driver. Safety regulations acc. to EN 60598 has to be
observed if the sum of forward voltage exceed the permitted
touchable value.
• The clearance and creepage distances are designed for working
voltages up to 250 V DC acc. to EN 62031/EN 60598.
• Please ensure standard ESD (electrostatic discharge) protection
measures are employed when handling and installing LED modules.
Electrostatic discharge can damage LEDs.
• To ensure problem-free operation, the specified maximum temperature at the tc and tp point (see "Operating Life") must be observed
(measured in accordance with EN 60598-1). To satisfy this point, it
is necessary to put measures in place to ensure any heat is dissipated from the LED module to the environment.
• A parallel connection of the modules is not allowed.
• Operating LED modules in the presence of certain chemical substances or in chemically enriched (aggressive) environments can
impair module functionality or even cause total module failure.
Detailed information can be found in our "Chemical Incompatibility"
PDF on our website www.vossloh-schwabe.com/en/home/
products/led-lighting-technology/notes-on-led-technology.html
• The photobiological safety of the LED modules must be classified
into risk groups in accordance with EN 62471: 2008.
– general lighting
exempt group:
WU-M-515
– other applications
risk group 2:
WU-M-515
Assessment in acc. with IEC/TR 62778:
Given a clearance of more than dmin, within which the lighting
intensity limit of Ethr = 1200 lx is attained, the classification goes
down to Risk Group 1.
Applied Standards
EN 62031
LED modules for general lighting – Safety specifications
pending
EN 62471
Photobiological safety of lamps and lamp systems
Product Guarantee
• 5 years
• The conditions for the Product Guarantee of the Vossloh-Schwabe
Group shall apply as published on our homepage
(www.vossloh-schwabe.com).
We will be happy to send you these conditions upon request.
The values contained in this data sheet can change due to technical innovations. Any such changes will be made without separate notification.
Vossloh-Schwabe Deutschland GmbH · Hohe Steinert 8 · 58509 Lüdenscheid · Germany · Phone +49 23 51/10 10 · Fax +49 23 51/10 12 17 · www.vossloh-schwabe.com
4
Download