Product family LV HRC strip type fuse-switch-disconnector LV HRC strip type fuseswitch-disconnectors are mainly used for power distribution in low voltage assemblies in accordance with IEC/EN 60439-1. The strips are type tested in accordance with IEC/EN 60947-3. Size 00-4a 1-pole and 3-pole switchable versions are available. 9-0 • Top or bottom cable connection as required • Optimum fuse pick-up contact • Direct-connection terminal • Double strip up to 1250A • 910A compact switch strips for 630kVA transformer supply • Multipurpose cover • Modular design • High breaking capacity • Low power loss • Use of standard earthing accessories Product group Product type 1-pole switchable Sizes 00 - 4a /160A - 1600A Page 09-04 LVHRC fuselinks 3-pole switchable Sizes 00 - 3 /160A - 1600A 09-06 HVHRC fuselinks LVHRC busbar disconnect strip, 1-pole switchable Size 3 / 630A - 1000A 09-08 LVHRC busbar disconnect strip, 3-pole switchable Size 3 / 630A - 1000A 09-10 Accessories Terminals and adapters Covers Designation plates, interlocks and position indicator Current transformers and spacer rollers Other accessories Dtype fuselinks Dtype fusebases 09-12 09-14 09-18 09-20 09-22 Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Drawings 09-24 Technical data 09-49 Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-1 Appendix Mounting of LV HRC fuse switch strips SL00 - 3 x 3 /100 Example with device and system accessories, busbar distance 100mm, 3-pole switchable 11 10 14 2 17 13 3 9 7 12 6 5 4 15 1 8 16 9-2 1 Strip base U-SL00-3 x 3 /100 10 Stop clip SC-SL00 /100 2 Strip top O-SL00-3 x 3 /100 11 Designation plate mount BZ-SL00 /100 3 Swing-in device D-SL00-3 x 3 /100 12 Terminalcompartment cover HA-SL00 /100 4 Flat terminal F-M8 x16 13 5 Clamp-type terminal S00 Cover holder with M4 thread AH-SL/ M4 14 6 V-terminal clamp P0070 Cover holder with quick-release lock AH-SL/ S 7 V-terminal clamp P0095 15 Cover support AHCT-SL 8 Busbar terminals SK-SL00 16 Terminal compartment extension HAV-SL00 /100 9 Position indicator EV-SL00 /100 17 Overreaching protection GO-SL00 /100 Mounting of LV HRC fuse switch strips SL1 - 3 x 3, SL2 - 3 x 3, SL3 - 3 x 3 Example with device and system accessories, busbar distance 185mm, 3-pole switchable LVHRC fuselinks 14 HVHRC fuselinks 13 15 7 Dtype fuselinks 6 Dtype fusebases 5 1 4 2 Switch-diss connector-fuseC (SASIL) LV HR system 3 16 Switchdisconnectorfuses (SASIL) BS system 11 10 Terminals 12 8 LV HRC stripfuseways 9 1 2 3 4 5 Strip base U-SL1 U-SL2 U-SL3 6 Strip top O-SL1/3 x 3 O-SL2/3 x 3 O-SL3/3 x 3 7 Screw terminal Connectiontype 3a Size 1 M10 x 25 Sizes 2, 3 M12 x 30 8 Multiple V box terminal Connectiontype 9 Terminal type KM2G-F 25-240mm2 Multiple box terminal Connectiontype 9 Terminal type KM2G 25-150mm2 185-300mm2 Retrofittable direct-connection terminal K2G/A 70-240mm2 Stud terminal Connectiontype 4a Sizes 1, 2, 3 M12 x 35 9 Stud terminal Connectiontype 4a-60 Sizes 1, 2, 3 M12 x 60 Kit for connection of 2 cable lugs per phase FK2 x 240 10 Terminalcompartment cover HA-SL123/10 LV HRC e strip-type fus s ector nn co switch-dis 11 Cover holder with M4 thread AH-SL/M4 12 Cover holder with quick-release lock AH-SL/S 13 Fastening clips with T profile AHCT-SL 14 Designation plate, top BZO-SL123 15 Position indicator EV-SL/3 x 3/10 16 Hang-up device MW-SL123 LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-3 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors 1-pole switchable 2.21.01.010 Size 00/160A to size 4a/1600A Product Definition Operational principle 3-pole LV HRC strip-type fuse switch-disconnectors for mounting on busbars. They combine three lengthwise-arranged 1-pole fuse switch-disconnectors in one unit. One contact of each phase (incoming contact) is connected to one phase of a 3-pole busbar system. The other contacts (outgoing contacts) are equipped with conductor terminals. The fuse switch-disconnectors are used for accomodating LV HRC fuse-links and thus for breaking of circuits. They are 1-pole switchable and can be switched under load. The universal swing-in devices allow the use of current meters in conjunction with meter fuses and piggyback fuses for piggyback fuses with sockets for temporary supply. The upper parts of the strips, which are protected to IP3X when fitted, have inspection holes for voltage testing in accordance with DIN VDE 0680 Part 5. The cable outlet (top or bottom) can be freely selected on site. Applications The universal LV HRC fuse switch-disconnectors are used in low voltage distribution cabinets, network and transformer stations and cable distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. The following current ratings are available: 160A, 250A, 400A, 630A, 910A, 1000A, 1250A and 1600A. tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The downward connecting bars are designed for flat termination as standard, but it is also possible to fit direct-connection terminals. The live parts of size 1-3 strips, such as contacts and discharge rails, remain back-of-hand proof after removal of the upper part due to the contact covers with integrated arcing chamber which remain at the base. Twist locks allow straightforward removal and fitting of the upper parts of the strips with the swing-in devices. Product construction The one-piece strip body, which accomodates current-carrying parts, consists of high-strength glass-fibre-reinforced polyester. The silver-plated contact system for accomodating the LV HRC fuse-links equipped with Accessories • Terminals [S00] • Busbar terminals [SK-SL00] • Busbar adapter [AL-SL00/42] • Terminal compartment cover [HA-SL123/10] • Terminal cover [HRV] 9-4 • Blanking plates [B-SL123] • Busbar covers [H-SL00] • Designation plates [BZO-SL123] • Current transformer mounting kit [1OW/L3-L/SL123] • Current transformer substructure [W01-100/5+H30/D12 ,5] • Railing kits [VS-SL3/1000] • Busbar support [SH100/185] • Piggyback fuse [HP-SE/L] • Connector kits [VBS-SL3X2(6)] • Cover holder [AH-SL/M4] • Assembly aid [MW-SL123] Size Busbar system Type of connection, size 00 (F: flat termination B: box terminal) Type of connection, sizes 1-3 (S: screw terminal ST: stud MB: multiple box terminal) Cable outlet (C: connection V: variable R: rear O: top B: bottom L: lateral) Swing-in device (S: standard RH: retractable handle) Std.P Type Art. no. SL... 00 185mm F V S 1 00-3X/F L5431002 00 185mm F V RH 1 00-3X/F/GV L5431040 00 185mm B V S 1 00-3X/KU00 L5496061 00 185mm B V RH 1 00-3X/KU00/GV L5496062 1 185mm S V S 1 1-3X/3A L1931001 1 185mm S V RH 1 1-3X/3A/GV L1931005 1 185mm ST, M12x35 V S 1 1-3X/4A L1941002 1 185mm ST, M12x35 V RH 1 1-3X/4A/GV L1941006 1 185mm ST, M12x60 V S 1 1-3X/4A-60 L1941003 1 185mm ST, M12x60 V RH 1 1-3X/4A-60/GV L1941007 1 185mm MB, fixed V S 1 1-3X/9/KM2G L1996029 1 185mm MB, fixed V RH 1 1-3X/9/KM2G/GV L1996030 1 185mm MB, loose V S 1 1-3X/9/KM2G-F L1996004 1 185mm MB, loose V RH 1 1-3X/9/KM2G-F/GV L1996008 2 185mm S V S 1 2-3X/3A L2931001 2 185mm S V RH 1 2-3X/3A/GV L2931006 2 185mm ST, M12x35 V S 1 2-3X/4A L2941002 2 185mm ST, M12x35 V RH 1 2-3X/4A/GV L2941007 2 185mm ST, M12x60 V S 1 2-3X/4A-60 L2941003 2 185mm ST, M12x60 V RH 1 2-3X/4A-60/GV L2941008 2 185mm MB, fixed V S 1 2-3X/9/KM2G L2996005 2 185mm MBl, fixed V RH 1 2-3X/9/KM2G/GV L2996010 2 185mm MB, loose V S 1 2-3X/9/KM2G-F L2996004 2 185mm MBl, loose V RH 1 2-3X/9/KM2G-F/GV L2996009 3/1000A 185mm S CRO S 1 3-3X/1000/ARO L3920303 3/1000A 185mm S V S 1 3-3X/1000/HA L3921300 3 185mm S V S 1 3-3X/3A L3931001 3 185mm S V RH 1 3-3X/3A/GV L3931005 3 185mm ST, M12x35 V S 1 3-3X/4A L3941002 3 185mm ST, M12x35 V RH 1 3-3X/4A/GV L3941006 3 185mm ST, M12x60 V S 1 3-3X/4A-60 L3941003 3 185mm ST, M12x60 V RH 1 3-3X/4A-60/GV L3941007 3 185mm MB, fixed V S 1 3-3X/9/KM2G L3996004 3 185mm MB, fixed V RH 1 3-3X/9/KM2G/GV L3996008 3 185mm MBl, loose V S 1 3-3X/9/KM2G-F L3996018 3 185mm MB, loose V RH 1 3-3X/9/KM2G-F/GV L3996048 3/910A 185mm S CO, 100 S 1 3-3X/910/AO-100 L3920209 3/910A 185mm S CO, 65 S 1 3-3X/910/AO-65 L3920214 3/910A 185mm S CO, 75 S 1 3-3X/910/AO-75 L3920210 3/910A 185mm S CRO S 1 3-3X/910/ARO L3920203 3/910A 185mm S CRO, 110 S 1 3-3X/910/ARO/110 L3920206 3/910A 185mm S CRBL S 1 3-3X/910/ARUS L3920204 3/910A 185mm S V S 1 3-3X/910/HA L3921200 3/1250A 185mm S V S 1 3-3X2/1250/HA L3921400 3/1600A 185mm S V S 1 3-3X2/1600/HA L3921402 4A / width 147 185mm S B S 1 TL4A-3AS/3X/2X3A/Q/147K L4231049 4A / width 147 185mm S T S 1 TL4A-3AS/3X/2X3A/Q/147K/AO L4231052 4A 185mm S B S 1 TL4A-3AS/3X/4 L4241002 4A 185mm S T S 1 TL4A-3AS/3X/4/AO L4241024 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-5 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors 3-pole switchable 2.21.02.010 Size 00/160A to size 3/1600A Product Definition Operational principle 3-pole LV HRC strip-type fuse switch-disconnectors for mounting on busbars. They combine three lengthwise-arranged 1-pole fuse switch-disconnectors in one unit. One contact of each phase (incoming contact) is connected to one phase of a 3-pole busbar system. The other contacts (outgoing contacts) are equipped with conductor terminals. The fuse switch-disconnectors are used for accomodating LV HRC fuse-links and thus for breaking of circuits. They are 3-pole switchable and can be switched under load. The universal swing-in devices allow the use of current meters in conjunction with meter fuses and piggyback fuses for piggyback fuses with sockets for temporary supply. The upper parts of the strips, which are protected to IP3X when fitted, have inspection holes for voltage testing in accordance with DIN VDE 0680 Part 5. The cable outlet (top or bottom) can be freely selected on site. Applications The universal LV HRC fuse switch-disconnectors are used in low voltage distribution cabinets, network and transformer stations and cable distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. The following current ratings are available: 160A, 250A, 400A, 630A, 910A, 1000A, 1250A and 1600A. tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The downward connecting bars are designed for flat termination as standard, but it is also possible to fit direct-connection terminals. The live parts of size 1-3 strips, such as contacts and discharge rails, remain back-of-hand proof after removal of the upper part due to the contact covers with integrated arcing chamber which remain at the base. Twist locks allow straightforward removal and fitting of the upper parts of the strips with the swing-in devices. Product construction The one-piece strip body, which accomodates current-carrying parts, consists of high-strength glass-fibre-reinforced polyester. The silver-plated contact system for accomodating the LV HRC fuse-links equipped with Accessories • Terminals [S00] • Busbar terminals [SK-SL00] • Busbar adapter [AL-SL00/42] • Terminal compartment cover [HA-SL123/10] • Terminal cover [HRV] 9-6 • Blanking plates [B-SL123] • Busbar covers [H-SL00] • Designation plates [BZO-SL123] • Position indicator [EV-SL123/3X3/10] • Current transformer mounting kit [1OW/L3-L/SL123] • Current transformer substructure [W01-100/5+H30/D12 ,5] • Railing kits [VS-SL3/1000] • Busbar support [SH100/185] • Piggyback fuse [HP-SE/L] • Connector kits [VBS-SL3X2(6)] Size Busbar distance Type of connection, size 00 (F: flat termination V: V-terminal clamp B: box terminal) Type of connection, sizes 1-3 (S: screw terminal ST: stud MB: multiple box terminal) Cable outlet (C: connection V: variable R: rear O: top B: bottom L: lateral) Electronic fuse monitor Std. P Type Art. no. LVHRC fuselinks SL... 00 100mm F B 1 00-3X3/100/Q/AL185/ES00 L6531720 00 100mm F V 400V-690VAC 1 00-3X3/100/Q/F L6531007 00 100mm V V 1 00-3X3/100/Q/P0070 L6523033 00 100mm V V 1 00-3X3/100/Q/P0095 L6523027 00 185mm F V 1 00-3X3/F L5531001 00 185mm B V 1 00-3X3/KU L5596033 1 185mm S V 1 1-3X3/3A L1031001 1 185mm S B 1 1-3X3/3A/ES00 L1031720 1 185mm ST, M12x35 V 1 1-3X3/4A L1041002 1 185mm ST, M12x60 V 1 1-3X3/4A-60 L1041003 1 185mm MB, fixed V 1 1-3X3/9/KM2G L1096026 1 185mm MB, loose V 1 1-3X3/9/KM2G-F L1096015 2 185mm S V 1 2-3X3/3A L2031001 2 185mm S B 1 2-3X3/3A/ES00 L2031720 2 185mm ST, M12x35 V 1 2-3X3/4A L2041002 2 185mm ST, M12x60 V 1 2-3X3/4A-60 L2041003 2 185mm MB, fixed V 1 2-3X3/9/KM2G L2096005 2 185mm MB, loose V 1 2-3X3/9/KM2G-F L2096015 3/1000A 185mm S CRO 1 3-3X3/1000/ARO L3020303 400V-690VAC 400V-690VAC 3/1000A 185mm S V 1 3-3X3/1000/HA L3021300 3 185mm S V 1 3-3X3/3A L3031001 3 185mm S B 1 3-3X3/3A/ES00 L3031720 3 185mm ST, M12x35 V 1 3-3X3/4A L3041002 3 185mm ST, M12x60 V 1 3-3X3/4A-60 L3041003 3 185mm MB, fixed V 1 3-3X3/9/KM2G L3096004 3 185mm MB, loose V 1 3-3X3/9/KM2G-F L3096012 3/910A 185mm S V 1 3-3X3/910/AO-100 L3020208 3/910A 185mm S V 1 3-3X3/910/AO-65 L3020214 3/910A 185mm S V 1 3-3X3/910/AO-75 L3020210 3/910A 185mm S CRO 1 3-3X3/910/ARO L3020203 3/910A 185mm S CRO,110 1 3-3X3/910/ARO/110 L3020218 3/910A 185mm S CRBL 1 3-3X3/910/ARUS L3020204 3/910A 185mm S V 1 3-3X3/910/HA L3021200 3/1250A 185mm S V 1 3-3X6/1250/HA L3021400 3/1600A 185mm S V 1 3-3X6/1600/HA L3021402 400V-690VAC HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-7 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors LV HRC busbar disconnect strip, 1-pole switchable 2.21.03.010 Size 3/630A-1000A Product Definition Operational principle LV HRC busbar disconnect strips are 3-pole LV HRC strip-type fuse switch-disconnectors for mounting on busbars. They combine three lengthwise-arranged 1-pole fuse switch-disconnectors in one unit. One contact of each phase (incoming contact) is connected to one phase of a 3-pole busbar system. The lateral outgoing connections allow coupling of a second distribution system. The busbar disconnect strips are used for accomodating LV HRC fuse-links and thus for breaking of circuits. They are 1-pole switchable and can be switched under load. The universal swing-in devices allow the use of current meters in conjunction with meter fuses and piggyback fuses for piggyback fuses with sockets for temporary supply. The upper parts of the strips, which are protected to IP3X when fitted, have inspection holes for voltage testing in accordance with DIN VDE 0680 Part 5. The terminal lugs led through at the right or left side, which allow coupling of a second busbar system, are arranged in such a way that the neighbouring strip can be fitted in a 100mm grid. Applications The LV HRC busbar disconnect strips are used in low voltage distribution cabinets, network and transformer stations and cable distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. The following current ratings are available: 630A, 910A and 1000A. glass-fibre-reinforced polyester. The silver-plated contact system for accomodating the LV HRC fuse-links equipped with tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The lateral (right or left) outgoing connections allow coupling of a second busbar system. The live parts such as contacts and discharge rails remain back-of-hand proof after removal of the upper part due to the contact covers with integrated arcing chamber which remain at the base. Twist locks allow straightforward removal and fitting of the upper parts of the strips with the swing-in devices. Product construction The one-piece strip body, which accomodates current-carrying parts, consists of high-strength Accessories • Terminal compartment cover [HA-SL123/10] • Blanking plates [B-SL123] 9-8 • Busbar covers [H-SL00] • Designation plates [BZO-SL123] • Busbar support [SH100/185] • Piggyback fuse [HP-SE/L] Size Busbar disconnection Std.P Type Art. no. SLT3-3S... 3 Left side 1 L/3X 3/1000A Left side 1 L/3X/1000 L3900001 L3900003 3/910A Left side 1 L/3X/910 L3900200 3 Right side 1 R/3X L3900002 3/1000A Right side 1 R/3X/1000 L3900004 3/910A Right side 1 R/3X/910 L3900201 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-9 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors LV HRC busbar disconnect strip, 3-pole switchable 2.21.04.010 Size 3/630A-1000A Product Definition Operational principle LV HRC busbar disconnect strips are 3-pole LV HRC strip-type fuse switch-disconnectors for mounting on busbars. They combine three lengthwise-arranged 1-pole fuse switch-disconnectors in one unit. One contact of each phase (incoming contact) is connected to one phase of a 3-pole busbar system. The lateral outgoing connections allow coupling of a second distribution system. The busbar disconnect strips are used for accomodating LV HRC fuse-links and thus for breaking of circuits. They are 3-pole switchable and can be switched under load. The universal swing-in devices allow the use of current meters in conjunction with meter fuses and piggyback fuses for piggyback fuses with sockets for temporary supply. The upper parts of the strips, which are protected to IP3X when fitted, have inspection holes for voltage testing in accordance with DIN VDE 0680 Part 5. The terminal lugs led through at the right or left side, which allow coupling of a second busbar system, are arranged in such a way that the neighbouring strip can be fitted in a 100mm grid. Applications The LV HRC busbar disconnect strips are used in low voltage distribution cabinets, network and transformer stations and cable distribution cabinets of power supply and industrial companies, where they comply with all power distribution requirements. The following current ratings are available: 630A, 910A and 1000A. glass-fibre-reinforced polyester. The silver-plated contact system for accomodating the LV HRC fuse-links equipped with tin-plated discharge rails ensures low power loss, optimum thermal characteristics and high switching capacity. The lateral (right or left) outgoing connections allow coupling of a second busbar system. The live parts such as contacts and discharge rails remain back-of-hand proof after removal of the upper part due to the contact covers with integrated arcing chamber which remain at the base. Twist locks allow straightforward removal and fitting of the upper parts of the strips with the swing-in devices. Product construction The one-piece strip body, which accomodates current-carrying parts, consists of high-strength Accessories • Terminal compartment cover [HA-SL123/10] • Blanking plates [B-SL123] • Busbar covers [H-SL00] 9-10 • Designation plates [BZO-SL123] • Position indicator [EV-SL123/3X3/10] • Busbar support [SH100/185] • Piggyback fuse [HP-SE/L] Size Busbar disconnection Std.P Type Art. no. SLT3-3S... 3 Left side 1 L/3X3 3/1000A Left side 1 L/3X3/1000 L3000001 L3000003 3/910A Left side 1 L/3X3/910 L3000200 3 Right side 1 R/3X3 L3000002 3/1000A Right side 1 R/3X3/1000 L3000004 3/910A Right side 1 R/3X3/910 L3000201 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-11 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors Accessories 2.21.05.010 Terminals and adapters Product Definition TERMINALS Terminals are connectors for direct connection between connecting bars and lines. BUSBAR TERMINALS Busbar terminals are used for drill-free direct contacting of the strip-fuseways on the busbars. BUSBAR ADAPTERS / ADAPTER CLIPS The adapters are required for combining different strip sizes, e.g. size 00 with sizes 1 to 3. Anwendungen CLAMP-TYPE TERMINAL The S00 terminals are suitable for fitting to size 00 strips for the connection of circular Cu conductors and Cu ribbon conductors. 9-12 V-TERMINAL CLAMP The P0070 V-terminal clamps are suitable for fitting to size 00 strips for the connection of circular and sector-shaped Al and Cu conductors. BOX TERMINAL The K2G/A box terminals can be retrofitted to size 1 to 3 strips with screw or stud terminal M12 x 35 and are suitable for the connection of circular and sector-shaped Al and Cu conductors. KIT FOR 2 CABLE LUGS The FK-2x240 kit is used for the connection of 2 cable lugs of max. 2 x 300mm² per phase to size 1 to 3 strips with screw terminal. It is suitable for cable lugs up to a width of 43mm. BUSBAR TERMINALS Busbar terminals are used for drill-free direct contacting of size 00 strips on the busbars. They are available for bar thicknesses of 5mm to 10mm and 10mm to 15mm. BUSBAR ADAPTER Busbar adapters allow 2 size 00 strips to be placed on a 185mm busbar system in combination with size 1 to 3 strips. ADAPTER CLIP Adapter clips allow a size 00 strip to be placed on a 185mm busbar system in combination with size 1 to 3 strips. Direct-connection terminal Std.P Type Art. no. Size 4a, 3-wire connection/95-185mm² AL/cu 1 K3G/3/AF40-50 K3203015 Size 4a, 4-wire connection/95-185mm² AL/cu 1 K3G/4/A40-50 K3204016 Size 4a, 2-wire connection/120-300mm² AL/cu 1 KV2HG/2/300/AF40-50 K2322064 Size 00 / bar thickness 5-10mm/10-70mm² AL/cu 1 P0070 k5141038 Size 00 / bar thickness 10-15mm/1,5-70mm² AL/cu 1 S00 K5041013 Kit for 2 cable lugs Std.P Type Art. no. For sizes 1-3 1 FK2X240-SL123 L8290160 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Box termina Std.P Type Art. no. For sizes 1-3/70-300mm² AL/cu 3 K2G/A K2201092 Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system busbar terminal Std.P Type Art. no. For size 00 / bar thickness 5-10mm 3 SK-SL00 L8570207 For size 00 / bar thickness 10-15mm 3 SK-SL00/15 L8570642 Switchdisconnectorfuses (SASIL) BS system Terminals PEN terminal Std.P Type Art. no. For 5-10mm busbar thickness 1 SK-S0070 K5441020 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis Adapter clip Std.P Type Art. no. For 1 strip, 185/185mm 1 AB-SL00/1 L8500262 For 1 strip, 185/100mm 1 AB185-SL00/100/1 L8600302 For 1 strip, 60/100mm 1 AB60-SL00/100/1 L8600178 Adapter strip Std.P Type Art. no. For 2 strips, 185/185mm, height 24mm 1 AL-SL00/24 L8500606 For 2 strips, 185/185mm, height 42mm 1 AL-SL00/42 L8500605 For 2 strips, 185/100mm 1 AL185-SL00/100/60,5 L8500607 LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-13 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors Accessories 2.21.05.020 Covers Product Definition Applications TERMINAL COMPARTMENT / TERMINAL COVER The terminal compartment and terminal covers provide probe-safe frontal protective covering of the terminal compartment. TERMINAL COMPARTMENT COVER The terminal compartment cover provides protective covering of the terminal compartment. It is mainly used for screw and stud terminal connection. BUSBAR COVER The busbar covers can be screwed or latched on the busbars for covering exposed strip locations. BLANKING PLATE / RESERVE PANEL COVER The blanking plate and reserve panel covers are used for frontal covering of exposed strip locations. COVER HOLDER / LATERAL COVER SUPPORT The cover holders and lateral cover support are used for fixing and supporting lateral covers. 9-14 TERMINAL COVER The HRV terminal cover is used to cover individual KM2 multiple box terminals. Used in conjunction with the KM2G-G terminal, it allows cable connection while the system is energized. In addition, it provides phase partitioning. BUSBAR COVER, CLIP-TYPE The clip-type protective covers of 100mm width are suitable for bar thicknesses of 5mm (6mm),10mm and 15mm and bar widths of 30mm to 100mm. Due to their elevated position, they can also cover studs up to a length of 35mm. BUSBAR COVER, SCREW-TYPE The screw-type covers of 100mm width are fixed at busbars with M12 thread or stud. The covers of 50mm width are fixed on busbars or adapters with M8 thread. BLANKING PLATE The blanking plate is used for frontal covering of exposed strip locations. It is placed on the switchboard at the bottom and is fixed at the top using an espagnolette. RESERVE PANEL COVER The reserve panel cover is used for frontal covering of exposed strip locations and is fixed at the strip sides using AH-SL/M4 or AH-SL/S cover holders. Shrouding cover Std.P Type Art. no. For KM2G multiple box terminals 1 HRV L8990573 Terminal compartment cover Std.P Type Art. no. For SL00 1 HA-SL00 L8550017 For SL123 1 HA-SL123/10 L8950666 For SL3-3x2(6) 1 HA-SL3X2/10 L8950675 For SL3/910(1000) 1 HA220-SL123/10 L8950673 For SL3/910(1000), extended 1 HA275-SL123/10 L8950674 For SL00-3x3/100 1 HAV-SL00/100 L8650209 Compensating adapters Std.P Type Art. no. For SL00-3x3/100 1 BO/BU-SL00/100 L8650171 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Blanking plate Std.P Type Art. no. For SL00 / width 50mm 1 B-SL00 L8520119 For SL00-3x3/100 / width 50mm 1 B-SL00/100 L8520386 For SL123 / width 100mm 1 B-SL123 L8220120 Terminals Busbar cover, clip-type Std.P Type Art. no. LV HRC stripfuseways 185mm busbar system / width 100mm 1 H-RF S8900954 LV HRC e strip-type fus s ector nn co switch-dis Busbar covers, screw-type Std.P Type Art. no. 185mm busbar system / width 50mm, M8 1 H-SL00 L8550068 100mm busbar system / width 50mm, M8 1 H-SL00/100 L8520323 185mm busbar system / width 100mm, M12 1 H-SL123 L8220083 185mm busbar system / width 100mm, M12/St 1 H-SL123/ST L8220166 LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Reserve panel cover Std.P Type Art. no. For SL00 / width 50mm 1 LA-SL00 L8520350 For SL123 / width 100mm 1 LA-SL123 L8920351 Consumer gy supply technolo Distribution nt and instrume cabinets Cover holder Std.P Type Art. no. With M4 thread 4 AH-SL/M4 L8290020 With quick-release lock 4 AH-SL/S L8290106 Electronic monitoring devices Measurement n data acquisitio s system Software 9-15 Appendix 9-16 Lateral cover support Std.P Type Art. no. 3 clips with T profile (length 650mm) 1 AHCT-SL L8990272 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-17 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors Accessories 2.21.05.030 Designation plates, interlocks and position indicator Product Definition Applications DESIGNATION PLATE MOUNT The plug-on designation plate mount can also be used as support for section covers. DESIGNATION PLATE MOUNT The designation plate mount is plugged on the strips at the end face. It allows fitting of an additional designation plate. When fitted in switchboards, it can also be used as support for a system cover. MECHANICAL INTERLOCK The stop clip enables sealing and locking. POSITION INDICATOR The position indicator indicates switch positions (connected or disconnected). 9-18 MECHANICAL INTERLOCK The stop clip for retrofitting to type „SL00-3x3/100" strips enables sealing and locking with up to 3 padlocks. POSITION INDICATOR The 3-pole switchable strips of the sizes 00-3 and size 4A strips allow fitting of auxiliary switches with freely selectable make or break (changeover) function for indication of the connected or disconnected position. Mechanical fuse monitor Std.P Type Art. no. Size 4a 1 K-LTL4A T8420057 Designation plate, top Std.P Type Art. no. For SL00 1 BZO-SL00 L8590656 For SL00-3x3/100 1 BZO-SL00/100 L8690170 For SL123 1 BZO-SL123 L8990251 Mechanical interlock Std.P Type Art. no. Stop clip for SL00-3x3/100 1 SC-SL00/100 L8690172 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Position indicator Std.P Type Art. no. For SL00-3x3/100 1 EV-SL00/100 L8690173 For SL00, 3-pole switchable 1 EV-SL00/3X3 L8990454 For SL123, 3-pole switchable 1 EV-SL123/3X3/10 L8990667 Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-19 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors Accessories 2.21.05.040 Current transformers and spacer rollers Product Definition CURRENT TRANSFORMER MOUNTING KITS The current transformer mounting kits consist of terminal lugs for retrofitting of current transformers in the connection area. CURRENT TRANSFORMER SUBSTRUCTURE The kits for the current transformer substructure between busbars and circuit strips consist of a current transformer with Cu spacer rollers. SPACER ROLLERS In the event of single-phase current measurement, the spacer rollers (height 9-20 30mm) are required for distance compensation at the contact gland of the non-measured phases. Anwendungen CURRENT TRANSFORMER MOUNTING KIT The current transformer mounting kits for mounting on size 1 to 3 strips are suitable for commercially available current transformers of the following dimensions: Max. external dimensions: height 70mm; width 60mm; depth 40mm Min. aperture dimensions for primary conductors: 30mm x 6mm CURRENT TRANSFORMER SUBSTRUCTURE The current transformers with spacer roller (height 30mm) are suitable for fitting between busbars and circuit strips of electrical low voltage distribution systems. The current transformers can be operated open for an unlimited period of time without any damage to the transformer. In association with the substructure kits, size 1-3 strips require insertion of special circuit strips with bracket connection to the busbar (3 x round hole, 14mm diameter). Current transformer mounting kit Std.P Type Art. no. For sizes 1-3, for 1 current transformer 1 1OW/L3-L/SL123 L8990658 For size 3/1000A, for 1 current transformer 1 1OW/L3-L/SL3/1000 L8390671 For sizes 1-3, for 3 current transformers 1 3OW-L/SL123 L8900652 Current transformer substructure, sizes 1-3 Std.P Type Art. no. Transformer 100/5 + spacer roller 1 W01-100/5+H30/D12,5 Y5000001 Transformer 125/5 + spacer roller 1 W01-125/5+H30/D12,5 Y5000011 Transformer 150/5 + spacer roller 1 W01-150/5+H30/D12,5 Y5000007 Transformer 200/5 + spacer roller 1 W01-200/5+H30/D12,5 Y5000005 Transformer 250/5 + spacer roller 1 W01-250/5+H30/D12,5 Y5000002 Transformer 300/5 + spacer roller 1 W01-300/5+H30/D12,5 Y5000012 Transformer 400/5 + spacer roller 1 W01-400/5+H30/D12,5 Y5000003 Transformer 50/5 + spacer roller 1 W01-50/5+H30/D12,5 Y5000009 Transformer 500/5 + spacer roller 1 W01-500/5+H30/D12,5 Y5000013 Transformer 600/5 + spacer roller 1 W01-600/5+H30/D12,5 Y5000004 Transformer 75/5 + spacer roller 1 W01-75/5+H30/D12,5 Y5000010 Current transformer substructure, size 00 Std.P Type Art. no. Transformer 100/5 + spacer roller 1 W01-100/5+H30/D8,5 Y5000016 Transformer 125/5 + spacer roller 1 W01-125/5+H30/D8,5 Y5000017 Transformer 150/5 + spacer roller 1 W01-150/5+H30/D8,5 Y5000006 Transformer 50/5 + spacer roller 1 W01-50/5+H30/D8,5 Y5000014 Transformer 75/5 + spacer roller 1 W01-75/5+H30/D8,5 Y5000015 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals LV HRC stripfuseways Spacer roller Std.P Type Art. no. For sizes 1-3 1 H30/D12,5 Y3000032 For size 00 1 H30/D8,5 Y3000087 LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-21 Appendix Current distribution components LV HRC strip-type fuse switch- disconnectors Accessories 2.21.05.050 Other accessories Product Definition Applications PIGGYBACK FUSE The piggyback fuse enables fuse-protected temporary connections (worksite electrical supply) to size 1 to 3 LV HRC strip-fuseways. PIGGYBACK FUSE The piggyback fuses are suitable for exchangeable size 00 LV HRC fuse-links up to 100A in accordance with DIN 43620 Part 1. Max. connection cross-section: 50mm². Their dimensions also make them suitable for use in flat cabinets. BUSBAR SUPPORT The 3-pole busbar support is used for the fixing of flat bars at 100mm and 185mm distances. ASSEMBLY AID The assembly aid allows size 1 to 3 circuit strips to be hanged at the busbars while the system is energized. RAILING KITS The kit for 1000A is used to expand the wiring space for 2 or 3 cable lugs per phase. The kit for 1250A allows 2 strips to be connected at the terminal and 3 or 4 cables per phase to be connected. CONNECTOR KITS The connector kits are used for parallel switching of 2 strips. 9-22 BUSBAR SUPPORT The 3-pole busbar support for 100mm and 185mm distance between busbar centres is used for the fixing of flat copper busbars of 30mm to 100mm width. The busbars can be additionally covered. ASSEMBLY AID The assembly aid allows the strips to be hanged at busbars of 5mm to 10mm thickness, which is particularly advantageous for mounting while the system is energized. RAILING KITS The kits for 1000A are used to expand the wiring space at size 2 and 3 strips for the connection of 2 cable lugs of max. 300mm² and 3 cable lugs of max. 120mm² per phase. The kits for 1250A allow 2 size 2 and 3 strips to be connected at the terminal and 3 cable lugs of max. 300mm² or 4 cable lugs of max. 185mm² to be connected per phase. The width of the cable lugs must not exceed 43mm. CONNECTOR KITS The connector kit enables 1-pole and 3-pole switchable strips of the sizes 1-3 to be connected at the swing-in devices for parallel switching. Fixing bracket Std.P Type Art. no. For sizes 1-3 1 MW-SL123 L8990621 Busbar support Std.P Type Art. no. For 100mm and 185mm busbar distance 1 SH100/185 S8900003 LVHRC fuselinks HVHRC fuselinks Piggyback fuse Std.P Type Art. no. Contact blade, long 3 HP-SE/L L8990491 Dtype fuselinks Dtype fusebases Railing kit Std.P Type Art. no. For SL3/1000A 1 VS-SL3/1000 L8390600 For SL3-3x2(6)/1250A 1 VS-SL3/1250 L8990669 Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Connector kit Std.P Type Art. no. For SL3-3x2(6) 1 VBS-SL3X2(6) L8990668 Terminals LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-23 Appendix 198 max. 500 150 110 160 7 80.5 49 L1 L1 L2 L2 295.5 185 647 633 185 8.5 L3 L3 189.5 15 93 SL000-3x/... Ordering details see page 9-5 SL1-3X/..., SL2-3X/..., SL3-3X/... Ordering details see page 9-5 9-24 21.5 17 55 30.5 40 40 3 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals SL3-3X/910/ARO Ordering details see page 9-5 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system SL3-3X/910/ARUS Ordering details see page 9-5 Software 9-25 Appendix SL3-3X/910/ARO/110 Ordering details see page 9-5 250 202 200 570 (cut out dimension min.) 285 185 14 14 185 662 765 L2 92.5 L3 153.5 99 L2 L3 SL3-3X/910/AO-100 Ordering details see page 9-5 9-26 L1 635 (cut out dimension max.) 14 368 L1 18 55 max. 15 18 20 16 200 202 150 20 16 18 55 max. 15 18 LVHRC fuselinks 14 570 (cut out demension min.) 185 662 L2 HVHRC fuselinks Dtype fuselinks 92.5 L3 635 (cut out demension max.) 765 14 185 14 285 368 L1 Dtype fusebases 153.5 Switch-diss connector-fuseC (SASIL) LV HR system 99 L2 Switchdisconnectorfuses (SASIL) BS system L1 L3 Terminals SL3-3X/910/AO-75 Ordering details see page 9-5 LV HRC stripfuseways 190 155 LV HRC e strip-type fus s ector nn co switch-dis 140 570 (cut out dimension min.) 185 662 L2 876.5 14 185 14 L3 635 (cut out dimension max.) 479.5 LV HRC fuse switchnn disco ectors 285 L1 18 4.5 LV HRC fusebases max. 15 90 94.5 14 20 80 40 Busbar system components Consumer gy supply technolo 92.5 Distribution nt and instrume cabinets 99 153.5 202 L3 Electronic monitoring devices L2 L1 Measurement n data acquisitio s system SL3-3X/910/AO-65 Ordering details see page 9-5 Software 9-27 Appendix SL3-3X/1000/ARO Ordering details see page 9-5 SL3-3X/910/HA Ordering details see page 9-5 9-28 190 44 42 202 153.5 L3 L2 L1 LVHRC fuselinks 35 HVHRC fuselinks 185 185 883 Dtype fuselinks 277.5 405 L3 570 (cut out dimension min.) 185 662 L2 635 (cut out dimension max.) 14 185 14 285 405 18 L1 HA2220-SL123 220 max. 15 35 35 20 Dtype fusebases 99.5 Switch-diss connector-fuseC (SASIL) LV HR system 35 L3 L2 L1 35 220 35 Switchdisconnectorfuses (SASIL) BS system HA220-SL123 20 42 44 Terminals 190 SL3-3X/1000/HA Ordering details see page 9-5 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system SL3-3X2/1250/HA Ordering details see page 9-5 Software 9-29 Appendix SL3-3X2/1600/HA Ordering details see page 9-5 198 max. 500 150 110 160 7 80.5 49 L1 L1 L2 L2 295.5 185 647 633 185 8.5 L3 L3 189.5 15 93 SL00-3X3/... Ordering details see page 9-5 9-30 21.5 17 55 30.5 40 40 3 43 255 125 110 96.5 70 49 LVHRC fuselinks 7 20 L1 HVHRC fuselinks 150 150 L1 100 9 L2 L2 150 180.5 100 410 Dtype fuselinks L3 L3 Dtype fusebases 36.5 36.5 Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system 14 36.5 59 110.5 Terminals SL00-3X3/100/Q/... Ordering details see page 9-7 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system SL00-3X3/100/Q/AL185/ES00 Ordering details see page 9-7 Software 9-31 Appendix SL1-3X3/..., SL2-3X3/..., SL3-3X3/... Ordering details see page 9-7 202 99 MAX. 15 153.5 341 185 662 792 L2 40 L3 570 (cut out dimension min.) 14 185 14 635 (cut out dimension max.) L1 285 18 130 HA-SL123 L1 N AC 230V L2 L1 L3 L1 L2 L3 26 51.5 SL1-3X3/3A/ES00, SL2-3X3/3A/ES00, SL3-3X3/3A/ES00 Ordering details see page 9-7 9-32 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals SL3-3X3/910/ARO Ordering details see page 9-7 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system SL3-3X3/910/ARUS Ordering details see page 9-7 Software 9-33 Appendix 92.5 SL3-3X3/910/AO-75 Ordering details see page 9-7 9-34 14 L2 765 max. 15 55 20 L3 765 185 285 153.5 L3 202 16 L3 153.5 99 L2 L3 L1 635 (cut out dimension max.) 570 (cut out dimension min.) 185 L2 635 (cut out demension max.) 368 L1 285 92.5 14 18 368 18 L1 185 14 14 max. 15 55 20 16 570 (cut out demension min.) 185 662 662 202 200 250 18 14 99 L2 L1 Ordering details see page 9-7 SL3-3X3/910/AO-100 150 200 18 14 190 155 140 max. 15 90 570 (cut out dimension min.) L3 635 (cut out dimension max.) 479.5 185 662 L2 876.5 185 14 14 LVHRC fuselinks HVHRC fuselinks 285 L1 18 4.5 14 80 40 20 94.5 Dtype fuselinks Dtype fusebases 92.5 Switch-diss connector-fuseC (SASIL) LV HR system 99 153.5 Switchdisconnectorfuses (SASIL) BS system 202 L3 L2 L1 Terminals SL3-3X3/910/AO-65 Ordering details see page 9-7 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system SL3-3X3/910/ARO/110 Ordering details see page 9-7 Software 9-35 Appendix SL3-3X3/1000/ARO Ordering details see page 9-7 SL3-3X3/910/HA Ordering details see page 9-7 9-36 190 44 42 202 153.5 L3 L2 L1 LVHRC fuselinks 35 HVHRC fuselinks 185 185 883 Dtype fuselinks 277.5 405 L3 570 (cut out dimension min.) 185 662 L2 635 (cut out dimension max.) 14 185 14 285 405 18 L1 HA2220-SL123 220 max. 15 35 35 20 Dtype fusebases 99.5 Switch-diss connector-fuseC (SASIL) LV HR system 35 L3 L2 L1 35 220 35 Switchdisconnectorfuses (SASIL) BS system HA220-SL123 20 42 44 Terminals 190 SL3-3X3/1000/HA Ordering details see page 9-7 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system SL3-3X6/1250/HA Ordering details see page 9-7 Software 9-37 Appendix SL3-3X6/1600/HA Ordering details see page 9-7 SL3-3X3/3A Ordering details see page 9-7 9-38 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals SLT3-S.../3X Ordering details see page 9-9 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system SLT3-3S.../3X3... Ordering details see page 9-11 Software 9-39 Appendix 15 15 M5 15 15 M5 25 S00 P0070 Ordering details see page 9-13 Ordering details see page 9-13 SK-SL00/10 SK-SL00/15 A 50 55 SK-SL00 AL-SL00/42 Ordering details see page 9-13 Ordering details see page 9-13 9-40 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals AL-SL00/24 AL185-SL00/100/60,5 Ordering details see page 9-13 Ordering details see page 9-13 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system AB60-SL00/100/1 AB185-SL00/100/1 Ordering details see page 9-13 Ordering details see page 9 -13 Software 9-41 Appendix AB-SL00/1 B-SL00 Ordering details see page 9-13 Ordering details see page 9-15 H-SL00/100 LA-SL00 Ordering details see page 9-15 Ordering details see page 9-15 9-42 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals B-SL00/100 HA-SL00 Ordering details see page 9-15 Ordering details see page 9 -15 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system H-SL00 BO/BU-SL00/100 Ordering details see page 9-15 Ordering details see page 9 -15 Software 9-43 Appendix 40 85 45 40.5 49 HAV-SL00/100 BZO-SL00/100 Ordering details see page 9-15 Ordering details see page 9-19 FK2X240-SL123 H-SL123 Ordering details see page 9-13 Ordering details see page 9-15 9-44 LVHRC fuselinks HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals B-SL123 H-SL123/ST Ordering details see page 9-15 Ordering details see page 9-15 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system H-RF AH-SL/M4 Ordering details see page 9-15 Ordering details see page 9 -15 Software 9-45 Appendix AH-SL/S LA-SL123 Ordering details see page 9-15 Ordering details see page 9-15 AHCT-SL HRV Ordering details see page 9-16 Ordering details see page 9-15 9-46 31 LVHRC fuselinks 58 HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system 90.5 Switchdisconnectorfuses (SASIL) BS system Terminals BZO-SL123 HP-SE/L Ordering details see page 9-19 Ordering details see page 9-23 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system MW-SL123 SH100/185 Ordering details see page 9-23 Ordering details see page 9-23 Software 9-47 Appendix K3G/3/AF40-50 K3G/4/A40-50 Ordering details see page 9-13 Ordering details see page 9-13 K2G/A KV2HG/2/300/AF40-50 Ordering details see page 9-13 Ordering details see page 9-13 9-48 Technical data for LV HRC strip type fuse-switch-disconnector ( in accordance with IEC / EN 60947-3 and VDE 0660 Part 107) Typ SL00 SL1 LVHRC fuselinks Rated operational voltage Electrical characteristics Rated operational current Conventional free air thermal current with fuses Conventional free air thermal current with solid links Rated frequency Rated insulation voltage Rated conditional short-circuit current Rated short-time withstandcurrent (1sec) Utilization category Rated making capacity Rated breaking capacity Rated impulse withstand voltage Operating cycles with current Total power loss at Ith (without fuse) Fuse-links Size to DIN 43 620 Max. rated current (gL/gG) Max. permis. power loss per fuse-link Operating cycles without current Mechanical characteristics Weight1) Busbar distance Cable Connection Flat terminal Terminal Terminal Terminal Terminal Type of protection Front side Device fitted Operating conditions Ambient temperature2) Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category 1) 2) Bolt diameter Cable lug (DIN 43 620) Flat bar Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Operational state Front cover open Ue Ie Ith Ith Ui Icw Uimp Pv V A A A Hz V kAeff kAeff A A V W IN Pv A W - kg mm Ma Ma Ma Ma Ma mm2 mm Nm mm2 Nm mm2 Nm mm2 Nm mm2 Nm - - IP30 IP10 IP30 IP10 Tu - °C m - -25 to +55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 III -25 to +55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 IV AC500 AC690 DC220 DC440 160 100 160 100 160 100 160 100 210A with TM00 40-60 40-60 AC750 50 50 25 25 AC-22B AC-22B DC-21B DC-21B 480 300 240 150 480 300 240 150 8 8 8 8 200 300 200 300 18 7 12 5 AC500 AC690 DC220 DC440 250 200 250 200 250 200 250 200 400A with TM2 40-60 40-60 AC1000 80 80 25 25 AC-22B AC-22B DC-21B DC-21B 1200 600 375 300 1200 600 375 300 12 12 8 8 200 200 200 200 23 15 16 11 00 160 100 HVHRC fuselinks Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system 1 160 100 250 200 250 12 32 1700 100mm=1,4 185mm= 2,4 100 /185 1400 4,9 185 M8 1 x 10 - 95 (max. 25 width) 20 x 10 12-15 1,5 -70Cu/ribbon 6 x 9 x 0,8 S 00 2,6 10 - 70 Al/Cu P 00 - 70 2,6 35 - 95 Al/Cu P 00- 95 KM2G 2,6 10 - 95 KU 00 KM2G - F 15 200 Switchdisconnectorfuses (SASIL) BS system Terminals M10/M12 1 x 25 - 150 30 x 10 30 - 35 25 -150/185 - 300 40 25 - 240 40 LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis LV HRC fusebases LV HRC fuse switchnn disco ectors Busbar system components Without packaging Consumer gy supply technolo Distribution nt and instrume cabinets Electronic monitoring devices 35°C Normal temperature, at 55°C with reduced operating current Measurement n data acquisitio s system Software 9-49 Appendix Technical data for LV HRC strip type fuse-switch-disconnector ( in accordance with IEC / EN 60947-3 and VDE 0660 Part 107) Typ SL2 Electrical characteristics Rated operational voltage Rated operational current Conventional free air thermal current with fuses Conventional free air thermal current with solid links Rated frequency Rated insulation voltage Rated conditional short-circuit current Rated short-time withstandcurrent (1sec) Utilization category Rated making capacity Rated breaking capacity Rated impulse withstand voltage Operating cycles with current Total power loss at Ith (without fuse) Fuse-links Size to DIN 43 620 Max. rated current (gL/gG) Max. permis. power loss per fuse-link Operating cycles without current Mechanical characteristics Weight1) Busbar distance Cable Connection Flat terminal Terminal Terminal Type of protection Front side Device fitted Operating conditions Ambient temperature2) Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category 1) 2) Bolt diameter Cable lug (DIN 43 620) Flat bar Tightening torque Clamping cross-section Tightening torque Clamping cross-section Tightening torque Operational state Front cover open Without packaging 35°C Normal temperature, at 55°C with reduced operating current 9-50 Ue Ie Ith Ith Ui Icw Uimp Pv V AC500 AC690 DC220 DC440 AC500 AC690 DC220 DC440 A 400 315 400 315 630 500 630 500 400 315 400 315 630 500 630 500 A 630A with TM3 800A with TM3/1250 A 40 - 60 40 - 60 Hz 40 - 60 40 - 60 AC1000 AC1000 V 80 80 25 25 80 80 25 25 kAeff kAeff AC-22B AC-22B DC-21B DC-21B AC-22B AC-22B DC-21B DC-21B 1890 945 600 475 2400 1500 945 750 A 1890 945 600 475 2400 1500 945 750 A 12 12 8 8 12 12 8 8 V 200 200 200 200 200 200 200 200 49 30 33 21 110 70 74 47 W IN Pv A W - kg mm Ma Ma Ma SL3 2 400 mm2 mm Nm mm2 KM2G Nm 2 mm KM2G-F Nm 315 3 400 315 630 500 630 45 48 1400 4,9 185 1000 5,6 185 M12 1 x 25 - 240 20 x 10 35 - 40 25 - 150/185 - 300 40 25 - 240 40 500 M12 1 x 25 - 300 (max. 43 widht) 30 x 10 35 - 40 25 - 150/185 - 300 KM2G 40 25 - 240 KM2G-F 40 - - IP30 IP10 IP30 IP10 Tu - °C m - -25 to +55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 IV -25 to +55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 IV Technical data for LV HRC strip type fuse-switch-disconnector ( in accordance with IEC / EN 60947-3 and VDE 0660 Part 107) Typ SL00 / 400 SL3 / 1000 LVHRC fuselinks Electrical characteristics Fuse-links Rated operational voltage Rated operational current Conventional free air thermal current with fuses Conventional free air thermal current with solid links Rated frequency Rated insulation voltage Rated conditional short-circuit current Rated short-time withstand current (1sec) Utilization category Rated making capacity Rated breaking capacity Rated impulse withstand voltage Operating cycles with current Total power loss at Ith (without fuse) Size to DIN 43 620 Max. rated current (gL/gG) Mechanical Operating cycles without current characteristics Weight1) Busbar distance Cable Connection Flat terminal Terminal Type of protection Front side Device fitted Operating conditions Ambient temperature2) Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category 1) 2) Bolt diameter Cable lug (DIN 43 620) Flat bar Tightening torque Clamping cross-section Tightening torque Operational state Front cover open Ue Ie Ith Ith Ui Icw Uimp Pv V A A A Hz V kAeff kAeff A A V W AC500 400 400 40-60 AC750 17 AC-21B 8 200 49 IN A TM00 - 26 400 TM3 / 1000 1000 - kg mm 800 3,5 185 800 8,5 185 Ma Ma mm2 mm Nm mm2 Nm - - IP30 IP10 IP30 IP10 Tu - °C m - -25 to + 55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 III -25 to + 55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 IV AC500 1000 1000 40-60 AC1000 25 AC-21B 2400 2400 12 100 300 AC400 1000 1000 40-60 AC1000 25 AC-22B 3000 3000 12 100 300 Dtype fuselinks Dtype fusebases Switch-diss connector-fuseC (SASIL) LV HR system Switchdisconnectorfuses (SASIL) BS system Terminals M12 max.2 x 300, 3 x120 80 x 10 35 - 40 KRO HVHRC fuselinks LV HRC stripfuseways LV HRC e strip-type fus s ector nn co switch-dis 1 x 25 - 150 20 LV HRC fusebases Without packaging LV HRC fuse switchnn disco ectors Busbar system components Consumer gy supply technolo 35°C Normal temperature, at 55°C with reduced operating current Distribution nt and instrume cabinets Electronic monitoring devices Measurement n data acquisitio s system Software 9-51 Appendix Technical data for LV HRC strip type fuse-switch-disconnector ( in accordance with IEC / EN 60947-3 and VDE 0660 Part 107) Typ SL3/ 910 Electrical characteristics Rated operational voltage Rated operational current Conventional free air thermal current with fuses Conventional free air thermal current with solid links Rated frequency Rated insulation voltage Rated conditional short-circuit current Rated short-time withstannd current (1sec) Utilization category Rated making capacity Rated breaking capacity Rated impulse withstand voltage Operating cycles with current Total power loss at Ith (without fuse) Size to DIN 43 620 Max. rated current (gL/gG) Max. permis. power loss per fuse-link Fuse-links Operating cycles without current Mechanical characteristics Weight1) Busbar distance Cable Connection Flat terminal Bolt diameter Cable lug (DIN 43 620) Flat bar Tightening torque Type of protection Front side Device fitted Operational state Front cover open Operating conditions Ambient temperature2) Rated operating mode Actuation Mounting position Altitude Pollution degree Overvoltage category 1) 2) Without packaging 35°C Normal temperature, at 55°C with reduced operating current 9-52 Ue Ie Ith Ith Ui Icw Uimp Pv V A A A Hz V kAeff kAeff A A V W AC400 910 910 AC400 910 910 50 50 AC400 910 910 AC400 910 910 50 50 50 AC - 22B 3750 3750 8 100 50 AC - 22B 3750 3750 8 100 IN Pv A W 910 910 - kg mm Ma mm2 mm Nm - - IP30 IP10 Tu - °C m - -25 to +55 Continuous operation Dependent manual operation Vertical, horizontal Up to 2000 3 IV 1250 AC500 50 AC - 22B 3750 3750 8 100 50 AC - 22B 3750 3750 8 100 260 3/910A 910 910 61 100 11,4 185 2 x M12 max. 2 x 300, 3 x185 80 x 10 35 - 40