ADJUSTABLE 40°
®
BeveLED5.0 Trimless
MAX OUTPUT
6331
PROJECT INFORMATION
PROJECT
®
DATE
TYPE
1" Regress
BeveLED 5.0 Max Output Recessed Adjustable- The BeveLED 5.0 provides maximum delivered lumens and optical performance
through the optimization of thermal,optical and LED science in a 6” aperture.
DELIVERED PERFORMANCE
®
BeveLED5.0
40 Watts
60 Watts
1" Regress Trim
80 Watts
1" Regress
Max Output - Downlight
Color Rendering
Lumens per Watt
Source Lumens
Delivered Lumens
Center Beam
Candle Power (10º)
Color Consistency
80+
90
3900
3550
42100
80+
83
5400
4900
80+
74
6650
6025
Bevel Finish
Optional
Lens
58200
72000
2 Step MacAdam Ellipse
4-7/8” Ø
Performance based on: 3000K
CCT MULTIPLIER 2700K
80+
Color Rendering Index CRI
Multiplier for
Lumen Output
0.91
6” Ø
3000K 3500K 4000K
80+
CRI
80+
CRI
80+
CRI
1.00
1.00
1.09
HOW TO SPECIFY
Ordering Example: Specify trim code and housing code to order: Example : 6331 - B1 - N - 10 - LRLA6 - 8480 - C2 - 27KS - 20 - NC1 - 277V - DIML2 - CB27
TRIM ORDERING INFORMATION
OPTIONAL
TRIM
BEVEL STYLE
OPTION
–
6331 _____
6331 W
Wet location 1
6”
Round
Trimless
Adjustable 1 Wet location, use with
BEVEL FINISH
LENS
–
B1 1” Regress Bevel,
Painted Die Cast
–
S Solite
N No Glass
(provided standard)
F Frosted
C Clear 2
B1 trims only. N/A with
millwork option.
AB1 1” Regress Bevel,
Black Anodized
Finish
AC1 1” Regress Bevel,
Clear Matte
Anodized Finish
10
13
21
28
RAL
White
Statuary Bronze
Black
Metalized Grey
Custom Color
(specify RAL #)
S Solite
N No Glass
(provided standard)
(Leave blank for AB1 and
F Frosted
AC1 Bevel Styles)
C Clear 2
2 Clear lens provided
standard with wet
location
HOUSING ORDERING INFORMATION
HOUSING
CODE
LRLA6
LRLA6
ENGINE
CODE
WATTAGE
–
–
8440 40W LED,
3550 lumens
8460 60W LED,
4900 lumens
8480 80W LED,
6025 lumens
C2
C2
COLOR
–
–
27KS
30KS
35KS
40KS
–
2700K, 80+ CRI 10 10° beam
3000K, 80+ CRI 20 20° beam
3500K, 80+ CRI
4000K, 80+ CRI
NC1
NC1
New Construction
5/8” - 1”
Ceiling Thickness
Please consult factory
for other CCT’s not
shown here
* Note:
For other
beam spread
2 Step MacAdam ellipse options, see
"Accessories"
is standard for all
–
–
USAI
Lighting
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
ACCESSORIES
–
OPTICAL
ACCESSORIES
(Order
separately)
For use with 120V or 277V
CB27 27” C-Channel Bars AL10J Refer to optical
DIML2 0-10V dim, 10%
CB52 52” C-Channel Bars AL15J accessories
120V
(provided standard)
277V
EML Emergency battery 4 AL20J matrix on next
page for
DIML3 Lutron Hi-Lume 1%
EMLW Emergency battery,
AL30J
resulting
2-wire, 120V only
wet location 4
AL40J beamspreads
DIML4 Lutron Hi-Lume 1%
MLXX Millwork Adapter
AS55J when accessory
3-wire/ECO
XX=Specify Color
AL80J lens is combined
(10, 13, 21, 28, RAL)
DIML6A EldoLED 0-10V, 0.1%,
with 10° and 20°
Millwork is not
logarithmic / Lutron controls
AS61J optics
available
with
wet
DIML6B EldoLED 0-10V
BOFJ Borosilicate Frosted
location
0.1%, linear controls
SOFJ Solite Frosted
DIML6E EldoLED 0-10V, 1%,
PRFJ Prismatic Prosted
logarithmic/Lutron controls
HEXJ Hex Cell Louver 1/8”
DIML6F EldoLED 0-10V, 1%,
linear controls
Clearly specify quantity
DIML7 EldoLED DALI, 0.1%
in your order
DIML8 EldoLED DMX, 0.1% 2
For use with 120V only
120V
DIML3 Lutron A 2-wire, 1%
120V only
3
®
DIMMING
DRIVER OPTIONS
REFLECTOR* HOUSING TYPE VOLTAGE
N/A with 80W
T 845–565–8500
F 845–561–1130
4 Above ceiling access required
© 2014. USAI, LLC.
All rights reserved.
All designs protected by copyright.
Revised 08/16/2016
ADJUSTABLE 40°
®
BeveLED5.0 Trimless
MAX OUTPUT
6331
®
TRIM INFORMATION
Optical Accessories Matrix
if you want…
and you have….
10°
20°
15° beam
AL10J N/A
20° beam
AL15J N/A
25° beam
AL30J AL15J
30° beam
N/A
AL20J
35° beam
N/A
AL30J
40° beam
N/A
AL40J
45° beam
N/A
AL55J
55° beam
N/A
AL80J
20x55° beam
AS61J N/A
40x60° beam
N/A
AS61J
size J
size J
1" Regress
4-7/8” Ø
6” Ø
HOUSING INFORMATION
New Construction Housing - NC1
Millwork Housing (shown with EM)
9-3/8”
9-3/8”
5/8” to 1”
Ceiling Thickness
1-1/4"
Maximum Ceiling Thickness
19-1/4”
Shown w/ EM
19-5/8”
16-5/8”
8-3/8”
19-5/8”
16-5/8”
without
Emergency
8-3/8”
20-1/8”
19-1/4”
with
Emergency
20-1/8”
SPECIFICATIONS
TRIM: 6" round aperture with a regressed bevel retained by
three ball plungers. Die cast aluminum bevel is available in
white, statuary bronze, black, and metalized grey finishes.
Also available in black anodized or clear matte anodized
bevel. Custom colors available (provide RAL#).
THERMAL MANAGEMENT: Proprietary high performance
aluminum die cast heatsink for maximum LED life. Ambient
temperatures at fixture location should not exceed 40°C
during normal operation.
FIELD REPLACEABLE DRIVER: 0-10V, 100%-10% solid state
TRIM LENS: Trim is not shipped with an integral lens unless electronic constant current DIML2 dimming driver with a
selected as an option. Solite or frosted lens available as an high power factor is provided standard and sources current
as follows:
option. Wet location is provided with a clear lens.
40W: sources 2mA per fixture
REFLECTOR: Interchangeable precision injection molded
60W: sources 4mA per fixture
polycarbonate optic optimized for 10° or 20° beam
80W: sources 4mA per fixture
distribution.
Specify 120V or 277V. Driver complies with IEEE C62.41
ADJUSTMENT: True hot aiming with center beam optics is surge protection.
adjustable, with a completely tool-less mechanism. 0°-40° DIMMING OPTIONS: Multiple dimming drivers available.
lockable vertical tilt with 362° lockable rotation.
See compatibility chart attached. Some on-time delay may
FIELD REPLACEABLE LIGHT ENGINE: Available with a 40W, be experienced depending on dimming driver and control
system used. Note: DIML6A and DIML6E logarithmic
60W or 80W (up to 6025 delivered lumens). Engine is field
control are intended for use with Lutron control systems;
replaceable through the aperture without tools.
DIML6B and 6F linear control are intended for use with nonCOLOR: BeveLED is available in 4 color temperatures (2700K, Lutron controls. DIML6 dimming driver sources 2mA for 40W
3000K, 3500K, 4000K). All color options are tightly binned
and 60W units, and 4mA for 80W units.
for fixture-to-fixture color consistency within a 2-Step
EMERGENCY: Emergency lighting battery pack with remote
MacAdam Ellipse. 80+ color rendering index provided
test switch requires above ceiling access, provides 190mA
standard.
for 90 minutes. EMLW wet location option is available with
RATED LIFE: Based on IESNA LM80-2008 50,000 hours at
B1 trim only and requires remote test switch and above
70% lumen maintenance (L70).
ceiling access as well.
MOUNTING: Butterfly brackets and adjustable
nailer bars with integral nails provided. Nailer bars
are extendible from 14” to 24” centers.
HOUSING: Fabricated of 20 ga. galvanized steel
with thru wire J-box, 4 in 4 out at min. 90°C, #12
AWG thru branch circuit wiring.
MAXIMUM CEILING THICKNESS: As per drawings
above. ML option for NC1: 1-1/4” thick wood max.
ACCESSORY HOLDER: Snap in accessory holder
shipped with fixture. Accepts 2 accessories
maximum, size J.
CEILING CUT OUT: 7" Ø
Millwork: 6-1/2” Ø
LISTINGS: Dry/Damp. Wet location option available
with B1 trim. Millwork for Dry/Damp only. IBEW
union made. NRTL/CSA-US tested to UL standards.
WARRANTY: 5 years
NOTES:
• Not for use in corrosive environment.
• Use of pressure washer voids warranty.
• Not for use with acoustical ceilings.
• Trimless for drywall installation only
• Serviceable from above.
• For interior use only.
PHOTOMETRICS: Consult factory or website for IES
files. Tested in accordance with IESNA LM79-2008.
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2014. USAI, LLC.
All rights reserved.
All designs protected by copyright.
Revised 08/16/2016
ADJUSTABLE 40°
®
BeveLED5.0 Trimless
MAX OUTPUT
6331
®
DELIVERED PERFORMANCE
6231 / 6331 40W 30KS 10°
6231 / 6331 40W 30KS 20°
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2014. USAI, LLC.
All rights reserved.
All designs protected by copyright.
Revised 08/16/2016
ADJUSTABLE 40°
®
BeveLED5.0 Trimless
MAX OUTPUT
6331
®
DELIVERED PERFORMANCE
6231 / 6331 60W 30KS 10°
6231 / 6331 60W 30KS 20°
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2014. USAI, LLC.
All rights reserved.
All designs protected by copyright.
Revised 08/16/2016
ADJUSTABLE 40°
®
BeveLED5.0 Trimless
MAX OUTPUT
6331
®
DELIVERED PERFORMANCE
6231 / 6331 80W 30KS 10°
6231 / 6331 80W 30KS 20°
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2014. USAI, LLC.
All rights reserved.
All designs protected by copyright.
Revised 08/16/2016
DIMMING DRIVER COMPATIBILITY
SELECTION GUIDE
DIML2
®
USAI
Lighting
DIMMING DRIVER WIRING SCHEMES:
NOTES:
Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are
not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS
- SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference.
2. Only qualified electricians in accordance to local codes should install these fixtures.
3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.
4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
5. Cap any wires not used separately (not together).
DIML2 LED: 0-10V Dimming Driver Wiring (Dims down to 10%)
DIML2 Dimmer Compatibility Chart
Manufacturer
120V / 277V
Crestron
Crestron
Crestron
Crestron
Crestron
Leviton
Lightolier (Philips)
Lutron
Product
Part Number
Dimmed Light
Output Range
iLux dimmer expansion module
DIN Rail dimmer
DIN Rail analog output module
8 Channel dimmer module
8 Channel dimmer module
IllumaTech dimmer
Vega
Diva
CLS-EXP-DIMFLV
DIN-4DIMFLV4
DIN-A08
GLX-DIMFLV8
GLXP-DIMFLV8
IP710-DLX
V2000FAMU
DVTV-XX
100% - 10%
100% - 10%
100% - 10%
100% - 10%
100% - 10%
100% - 10%
100% - 10%
100% - 10%
Qty Fixtures
Per Dimmer*
Use source current per
fixture specification
sheet to determine
number of fixtures per
dimmer. Max number
of fixtures is limited by
dimmer load rating.
* NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details.
DIML2
0-10V DIMMING W/RELAY TO SWITCH POWER
FIXTURE
DIMMER: 0-10V
(BY OTHERS)
0-10V (-)
GRAY
0-10V (+)
PURPLE
SWITCHED HOT
BLACK
NEUTRAL
WHITE
LED
DRIVER
V+
RED
V-
BLACK
NOTE:
If switched, non-dimming operation is desired,
cap off purple and gray wires individually at
installation. Do NOT cap purple and gray wires
together.
GREEN
GND
CLASS 2 CONTROL WIRES
LINE
RELAY
(BY OTHERS)
NEUTRAL
DIMMER: 0-10V w/
POWER SWITCHING
DIML2
0-10V DIMMING (NO RELAY)
FIXTURE
(BY OTHERS)
LINE
0-10V (-)
GRAY
0-10V (+)
PURPLE
SWITCHED HOT
BLACK
NEUTRAL
WHITE
LED
DRIVER
V+
RED
V-
BLACK
NOTE:
If switched, non-dimming operation is desired,
cap off purple and gray wires individually at
installation. Do NOT cap purple and gray wires
together.
GREEN
GROUND
GND
NEUTRAL
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2016. USAI, LLC.
All rights reserved.
All designs protected by copyright.
I2-264-2 Revised 02/15/2016
DIMMING DRIVER COMPATIBILITY
SELECTION GUIDE
DIML3
®
USAI
Lighting
DIMMING DRIVER WIRING SCHEMES:
NOTES:
Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are
not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS
- SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference.
2. Only qualified electricians in accordance to local codes should install these fixtures.
3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.
4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
5. Cap any wires not used separately (not together).
DIML3 LED: Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / LED Dimming Driver Wiring (Dims down to 1%) 120V only.
DIML3 Dimmer Compatibility Chart
Manufacturer
120V Only
ETC
ETC
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Product
Part Number
Dimmed Light
Output Range
Sensor+ Cabinet
Unison DRd Cabinet
Maestro Wireless® 600W dimmer
Maestro Wireless® 1000W dimmer
HomeWorks® QS adaptive dimmer
HomeWorks® QS 600W dimmer
HomeWorks® QS 1000 W dimmer
Caseta Wireless® Pro 1000W dimmer
Stanza® dimmer
RadioRA® 2 adaptive dimmer
RadioRA® 2 1000 W dimmer
myRoom DIN power module
HomeWorks® QS wallbox power module
Homeworks® DIN power module
HomeWorks® wallbox power module
GRAFIK Eye® QS control unit
GRAFIK Eye® 3000 control unit
RPM-4U module
RPM-4A module
GP dimming panels
Ariadni CL 250W dimmer
Diva CL 250W dimmer
Grafik T CL or RF CL dimmer
Nova T CL 250W dimmer
ELV10
ELV10
MRF2-6ND-120MRF2-10ND-120HQRD-6NAHQRD-6NDHQRD-10NDPD-10NXDSZ-6NDRRD-6NARRD-10NDMQSE-4A1-D
HQRJ-WPM-6D-120LQSE-4A1-D
HWI-WPM-6D-120
QSGR-, QSGRJGRX-3100-, GRX-3500HW-RPM-4U-120, LP-RPM-4U-120
HW-RPM-4A-120, LP-RPM-4A-120
Various
AYCL-253PDVCL-253P-, DVSCCL-253PGT-250M-, GTJ-250MNTCL-250-
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100% - 1%
100%-1%
100%-1%
100%-1%
100%-1%
Qty Fixtures Per Dimmer*
Fixture Wattage
39W and Less 40W - 80W
1 – 26
1 – 13
1 – 26
1 – 13
1–8
1–4
1 – 13
1–6
1–8
1–4
1–8
1–4
1 – 13
1–6
1 – 13
1–6
1–8
1–4
1–8
1–4
1–6
1–3
1–6
1–3
1 – 26
1 – 13
1–6
1–3
1 – 26
1 – 13
1 – 26
1 – 13
1 – 26
1 – 13
1 – 26
1 – 13
1 – 26
1 – 13
1 – 26
1 – 13
1–8
1–4
1–8
1–4
1–8
1–4
1 – 10
1–5
* NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details.
DIML3
2 WIRE PHASE DIMMING
FIXTURE
DIMMER: 2 WIRE PHASE
(BY OTHERS)
LED
LINE
SWITCHED HOT
NEUTRAL
GROUND
BLACK
WHITE
DRIVER
V+
RED
V-
BLACK
GREEN
GND
ONLY FOR SWITCHES WITH NEUTRAL
NEUTRAL
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2016. USAI, LLC.
All rights reserved.
All designs protected by copyright.
I2-264-3 Revised 02/15/2016
DIMMING DRIVER COMPATIBILITY
SELECTION GUIDE
DIML4
®
USAI
Lighting
DIMMING DRIVER WIRING SCHEMES:
NOTES:
Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are
not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS
- SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference.
2. Only qualified electricians in accordance to local codes should install these fixtures.
3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.
4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
5. Cap any wires not used separately (not together).
DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%)
DIML4 3-Wire Dimmer Compatibility Chart
Manufacturer
120V Only
ETC
ETC
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
277V Only
ETC
ETC
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Lutron
Product
Part Number
Dimmed Light
Output Range
Sensor+ Cabinet
Unison DRd Cabinet
Nova T
Nova T
Nova
Nova
Vareo
Skylark
Diva
Ariadni
Vierti
Maestro
Maestro Wireless
RadioRA 2
HomeWorks QS
Interfaces
GP Dimming Panels
D20 Dimming module
D20F Dimming module
NTF-10NTF-103PNF-10NF-103PVF-10SF-10P-, SF-103PDVF-103P-, DVSCF-103PAYF-103PVTF-6AMAF-6AM-, MSCF-6AMMRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV
PHPM-3F-120, PHPM-3F-DV
Various
100% - 1%
100% - 1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
Sensor+ Cabinet
Unison DRd Cabinet
Nova T
Nova T
Nova
Nova
Skylark
Diva
Ariadni
Vierti
Maestro
Maestro Wireless
RadioRA 2
HomeWorks QS
Interfaces
GP Dimming Panels
D20 Dimming module
D20F Dimming module
NTF-10-277NTF-103P-277NF-10-277NF-103P-277SF-12P-277-, SF-12P-277-3
DVF-103P-277-, DVSCF-103P-277AYF-103P-277VTF-6AMAF-6AM-277-, MSCF-6AM-277MRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV
PHPM-3F-DV
Various
100% - 1%
100% - 1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
100%–1%
Qty Fixtures Per Control*
Fixture Wattage
39W and Less 40W - 80W
1–53
1–26
1–53
1–26
1–41
1 – 20
1–20
1 – 10
1–41
1 – 20
1–20
1 – 10
1–20
1 – 10
1–20
1 – 10
1–20
1 – 10
1–20
1 – 10
1–15
1–7
1–15
1–7
1–15
1–7
1–15
1–7
1–15
1–7
1–41
1 – 20
1–41
1 – 20
40W and Less 41W - 80W
1–53
1–26
1–53
1–26
1–44
1 – 22
1–33
1 – 16
1–44
1 – 22
1–33
1 – 16
1–33
1 – 16
1–33
1 – 16
1–44
1 – 22
1–33
1 – 16
1–20
1 – 10
1–33
1 – 16
1–33
1 – 16
1–33
1 – 16
1–88
1 – 44
1–88
1 – 44
* NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's
documentation for installation instructions and circuit details.
DIML4 wiring diagrams continued on next page
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2016. USAI, LLC.
All rights reserved.
All designs protected by copyright.
I2-264-4 Revised 02/15/2016
DIMMING DRIVER COMPATIBILITY
SELECTION GUIDE
DIML4 Continued
®
USAI
Lighting
DIMMING DRIVER WIRING SCHEMES:
NOTES:
Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are
not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS
- SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference.
2. Only qualified electricians in accordance to local codes should install these fixtures.
3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.
4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
5. Cap any wires not used separately (not together).
DIML4 LED: Lutron Hi-Lume A-Series LED Driver with 3-Wire FL Control / LED Dimming Driver Wiring (Dims down to 1%)
DIML4
3 WIRE PHASE DIMMING
FIXTURE
DIMMER: 3 WIRE PHASE
(BY OTHERS)
CAP UNUSED
ECOSYS WIRES
DIMMED HOT
SWITCHED HOT
NEUTRAL
LINE
LED
PURPLE GRAY
PURPLE
ORANGE
BLACK
WHITE
GREEN
GROUND
DRIVER
V+
RED
V-
BLACK
GND
NEUTRAL
DIML4 LED: Lutron Hi-Lume A-Series LED Driver with EcoSystem Control / LED Dimming Driver Wiring (Dims down to 1%)
Manufacturer
120V / 277V
Lutron
Lutron
Lutron
Lutron
DIML4 EcoSystem Dimmer Compatibility Chart
Dimmed Light
Part Number
Output Range
Product
PowPak dimming module
Energi Savr Node
GRAFIK Eye QS (120V ONLY)
Quantum
RMJ-ECO32-DV-B
QSN-1ECO-S, QSN-2ECO-S
QSGRJ-_E, QSGR-_E
Various
100%–1%
100%–1%
100%–1%
100%–1%
Qty Fixtures Per Control*
Fixture Wattage
39W and Less 40W - 80W
1–32
1 – 16
1–64
1 – 32
1–64
1 – 32
1–64
1 – 32
* NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's
documentation for installation instructions and circuit details.
DIML4
EcoSystem CONTROLS
ECOSYS BUS
E2
E1
E2
FIXTURE
E1
WALL CONTROL
(BY OTHERS)
LINE
NEUTRAL
CAP
UN-USED
ORANGE
WIRE
PURPLE GRAY
PURPLE
ORANGE
BLACK
WHITE
GREEN
LED
DRIVER
V+
RED
V-
BLACK
GND
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2016. USAI, LLC.
All rights reserved.
All designs protected by copyright.
I2-264-4 Revised 02/15/2016
DIMMING DRIVER COMPATIBILITY
SELECTION GUIDE
DIML6A, 6E
DIML6B, 6F
®
USAI
Lighting
IMPORTANT SAFETY INSTRUCTIONS
- SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference.
2. Only qualified electricians in accordance to local codes should install these fixtures.
3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.
4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
5. Cap any wires not used separately (not together).
DIML6A and DIML6E LED Dimming Compatibility Table
DIML6A and DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below)
DIML6A = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1%
DIML6E = EldoLED ECOdrive 0-10V control dims from 100% to 1%
Dimmed Light Qty Fixtures
Manufacturer Product
Part Number
Output Range Per Dimmer*
Refer to manufacturer's
120V & 277V
DIML6A / E
Lutron
Diva
DVTV/NFTV/NTFTV with PP-20
99% - 0.1% / 1% dimmer load rating for
Lutron
Energi Savr Node
QSN-4T16-S
100% - 0.1% / 1% maximum and minimum
Lutron
GP Dimming Panels TVM2 Module
99% - 0.1% / 1% fixture quantities per
Lutron
Interfaces
GRX-TVI w/ GRX3503
100% - 0.1% / 1% dimmer.
Sensor Switch nIO
nIO EZ
100% - 0.1% / 1%
* NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details.
DIML6B and DIML6F LED Dimming Compatibility Table
DIML6B and DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-Lutron and others listed in the table below)
DIML6B = EldoLED SOLOdrive 0-10V control dims from 100% to 0.1%
DIMMER: 0-10V
DIML6F = EldoLED ECOdrive
(BY OTHERS) 0-10V control dims from 100% to 1%
0-10V (-)
GRAY
0-10V (+)
PURPLE
LED
DIML6B Dimmer Compatibility Chart
Dimmed Light
Qty Fixtures
V+
RED
SWITCHED HOT
SWITCHED
HOTNumber DRIVER
Manufacturer
Product
Part
Output Range
Per Dimmer*
VBLACK
NEUTRAL
WHITE
Refer to
120V & 277V
DIML6B / F
GREEN 2112U-101
Bush-Jaeger
Electronic potentiometer
100% - 0.1% / 1% manufacturer's
Jung
Electronic potentiometer
100% - 0.1% / 1% dimmer load
GND 240-10
CLASS 2 CONTROL WIRES
Leviton
IllumaTech dimmer
IP710-DLX
100% - 0.1% / 1% rating for
LINE
Lightolier
(Philips) Momentum (120V ONLY)
ZP600FAM120
100% - 0.1% / 1% maximum and
RELAY
Merten
Electronic
potentiometer
5729
100% - 0.1% / 1% minimum fixture
(BY OTHERS)
DIML6A,
6B
Pass & Seymour Titan
CD4FB-W
100% - 0.1% / 1% quantities per
NEUTRAL
TO SWITCH POWER
Watt Stopper
Miro 0-10V DIMMING W/RELAY
DCLV1
100% - 0.1% / 1% dimmer.
Synergy
Wallbox Dimmers
ISD BC
100% - 0.1% / 1%
ABB
i-bus
SD/S 2.16.1
100% - 0.1% / 1%
Crestron
Modules
GLX-DIMFLV8, GLXP-DIMFLV8
100% - 0.1% / 1%
Crestron
Green Light
GLPAC-DIMFLV4-, GLPAC-DIMFLV8100% - 0.1% / 1%
DIML6A, 6B
0-10V (-)
Crestron
Green Light Power Pack
GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM,
GLPP-1DIMFLV3EX-PM
100% - 0.1% /FIXTURE
1%
0-10V DIMMING
W/RELAY TO GRAY
SWITCH POWER
0-10V (+)
PURPLE
DIMMER: 0-10V
Crestron
DIN Rail Analog Output Module
DIN-A08
100% - 0.1% / 1% V+ RED
SWITCHED HOT
BLACK
Crestron
DIN Rail 0-10V Fluorescent Dimmer
DIN-4DIMFLV4
100% - 0.1% / 1% LEDV- BLACK
NEUTRAL
WHITE
GREEN
Crestron
iLux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV
100% - 0.1% / 1%
DRIVER
GND
* NOTE: Refer to dimmer manufacturer's documentation for installation instructions andCLASS
circuit
details.
2 CONTROL WIRES
(BY OTHERS)
LINE
DIMMING DRIVER WIRING SCHEMES:
RELAY
(BY OTHERS)
NOTES:
NEUTRAL
Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are
not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
DIML6
0-10V DIMMING (NO RELAY)
DIML6
0-10V DIMMING W/RELAY TO SWITCH POWER
FIXTURE
(BY OTHERS)
0-10V (-)
GRAY
0-10V (+)
PURPLE
SWITCHED HOT
BLACK
NEUTRAL
WHITE
(BY OTHERS)
LED
DRIVER
V+
RED
V-
BLACK
LINE
GREEN
GROUND
GND
0-10V (-)
GRAY
0-10V (+)
PURPLE
SWITCHED HOT
BLACK
NEUTRAL
WHITE
LED
DRIVER
V+
RED
V-
BLACK
GREEN
GND
CLASS 2 CONTROL WIRES
LINE
FIXTURE
DIMMER: 0-10V w/
POWER SWITCHING
DIMMER: 0-10V
RELAY
(BY OTHERS)
NEUTRAL
NEUTRAL
USAI
Lighting
®
www.usailighting.com
DIML6A, 6B
info@usailighting.com
1126 River Road
New Windsor, NY 12553
0-10V DIMMING (NO RELAY)
DIMMER: 0-10V w/
POWER SWITCHING
(BY OTHERS)
FIXTURE
T 845–565–8500
F 845–561–1130
© 2016. USAI, LLC.
All rights reserved.
All designs protected by copyright.
I2-264-6 Revised 05/20/2016
DIMMING DRIVER COMPATIBILITY
SELECTION GUIDE
DIML7
®
USAI
Lighting
DIMMING DRIVER WIRING SCHEMES:
NOTES:
Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are
not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS
- SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference.
2. Only qualified electricians in accordance to local codes should install these fixtures.
3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.
4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
5. Cap any wires not used separately (not together).
DIML7 LED: EldoLED DALI Dimming Driver Wiring (Dims down to 0.1%)
DIML7
DALI CONTROLS
DALI BUS
DA
DA
FIXTURE
WALL CONTROL
(BY OTHERS)
LINE
NEUTRAL
LED
ORANGE (-)
ORANGE/WHITE (+)
BLACK
WHITE
GREEN
DRIVER
V+
RED
V-
BLACK
GND
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2016. USAI, LLC.
All rights reserved.
All designs protected by copyright.
I2-264-7 Revised 02/15/2016
DIMMING DRIVER COMPATIBILITY
SELECTION GUIDE
DIML8
®
USAI
Lighting
DIMMING DRIVER WIRING SCHEMES:
NOTES:
Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are
not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details.
IMPORTANT SAFETY INSTRUCTIONS
- SAVE THESE INSTRUCTIONS
1. Keep these instructions in a safe place for future reference.
2. Only qualified electricians in accordance to local codes should install these fixtures.
3. De-energize the electrical circuit at the circuit breaker prior to installation process or servicing.
4. Make sure all connections are in accordance with the National Electrical Code and any local regulations.
5. Cap any wires not used separately (not together).
DIML8 LED: EldoLED DMX Dimming Driver Wiring (Dims down to 0.1%)
DMX BUS - XLR CABLE OR
SHIELDED DATA CABLE
The data cable used must meet the following requirements:
• type: shielded, 2-conductor twisted pair
• maximum capacitance between conductors: 30 pF/ft
• maximum capacitance between conductor and shield: 55 pF/ft
• maximum resistance: 0.02 ohms/ft
• normal impedance: 100-140 ohms
• conductive core: 24 AWG is recommended
If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets
the specifications for EIA RS-485 applications. Do not use standard microphone cables: they
cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device
(by others) should be used on last fixture in line on a circuit to avoid signal loss.
DMX BUS - XLR CABLE OR
SHIELDED DATA CABLE
SHIELD
DMX (-)
DMX (+)
5 PIN XLR JACKS STANDARD
8 BIT DMX 512
CONTROLLER
(BY OTHERS)
LINE
NEUTRAL
RED
BLACK
BARE
BLACK
WHITE
GREEN
LED
DRIVER
V+
RED
V-
BLACK
GND
FIXTURE
USAI
Lighting
®
www.usailighting.com
info@usailighting.com
1126 River Road
New Windsor, NY 12553
T 845–565–8500
F 845–561–1130
© 2016. USAI, LLC.
All rights reserved.
All designs protected by copyright.
I2-264-8 Revised 02/15/2016