Installation Instructions

advertisement
®
4-Port PoE+ Hardened Switches
Installation Manual
NetWay4EWP
NetWay4EPL
NetWay4EWPX
NetWay4EB
-NEMA4/4X rated Outdoor enclosure
-NEMA4/4X rated Outdoor enclosure
-Accommodates up to (4) 12VDC/7AH batteries
-Backplane version
-4-port switch, board only
NetWay4EX
-NEMA1 rated Indoor enclosure
DOC#: NetWay4E Rev. 041916
More than just power.™
Overview:
Altronix NetWay Indoor/Outdoor PoE+ Hardened Switches provide a 1Gb SFP port and four (4) PoE+ (30W) ports, passing data for PoE/PoE+ compliant devices.
Cameras/edge devices may be located up to 100m from the unit.
Input:
• 115VAC 60 Hz, 3A or 230VAC 50/60 Hz, 1.65A
Features:
Applications:
• Provides PoE / PoE+ / Hi-PoE for cameras/devices.
Power Output:
Mechanical:
NetWay4EWP
• NEMA 4X, IP66 Rated enclosure for outdoor use.
• Dimensions (H x W x D approx.):
13.31” x 11.31” x 5.59” (338.1mm x 287.3mm x 142mm)
NetWay4EWPX
• NEMA 4X, IP66 Rated enclosure for outdoor use.
• Accommodates four (4) 12VDC/7AH batteries (48V of backup).
• Dimensions (H x W x D approx.):
17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm)
NetWay4EX
• Dimensions (H x W x D approx.):
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
NetWay4EPL
• Dimensions (H x W x D approx.):
10.75” x 8.875” x 2.375” (273.05mm x 225.42mm x 60.32mm)
NetWay4EB
• Dimensions (L x W x D approx.):
6.25” x 4.5” x 0.625” (158.75mm x 114.3mm x 15.875mm)
• 4-ports maximum power: PoE+ (30W)
• IEEE 802.3at (30W) and IEEE 802.3af (15W) compliant.
• 120W total power.
• Integral surge protection.
Fiber Port:
• One (1) Gigabit SFP port.
Ethernet:
• Connectivity: RJ45, auto-crossover.
• Wire type: 4-pair Cat-5 or better structured cable.
• Distance: up to 100m.
•Speed: 10/100/1000Mbps, half/full duplex, auto negotiation.
Battery Backup:
• Built-in charger for sealed lead acid or gel type batteries.
• Automatic switch over to stand-by battery when AC fails.
• Maximum charge current 0.3A.
LEDs:
• LED1: PoE active on Spare. LED2: PoE active on Signal.
Environmental:
• Operating Temperature (30W): --- 30ºC to 70ºC (--- 22ºF to 158ºF).
• Storage Temperature: --- 30ºC to 85ºC (--- 22ºF to 185ºF).
• Humidity: 20 to 85%, non-condensing.
www.altronix.com
- 2 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
­­­Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
NetWay4EX Enclosure Installation:
1. Mount unit in the desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the enclosure. Install two (2) upper fasteners and
screws in the wall with the screw heads protruding. Place the enclosure’s upper keyholes over the two (2) upper screws; level and secure. Mark the position
of the lower two (2) holes. Remove the enclosure. Drill the lower holes and install two fasteners. Place the enclosure’s upper keyholes over the two (2) upper
screws. Install the two (2) lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 8-11). Secure enclosure to earth ground.
NetWay4EWP/4EWPX Enclosure Installation:
1. Remove backplane from enclosure prior to drilling enclosure (do not discard hardware).
Note: Take care to assure that hardware will not interfere with components of the circuit board.
2. Mark and drill desired inlets on the enclosure to facilitate wiring. Maximum NEMA type 4X rated fittings to be used is 1/2”,
follow manufacturer’s specifications for the appropriate size opening.
Note: Inlets for conduit fittings should only be made on the bottom of the enclosure. UL Listed NEMA type 4X rated conduit connector/hubs shall be
used for the appropriate size inlets.
3. Clean out the inside of enclosure before remounting circuit board.
4. Mounting NEMA 4X rated enclosure:
Wall mount: Mount unit in desired location. Mark and drill holes to line up with the top and bottom holes of the enclosure flange. Secure enclosure with
appropriate fasteners (e. g. screws and anchors; bolts and locking nuts, etc.) which are compatible with mounting surface and are of sufficient
length/construction to ensure a secure mount (Fig. 2, pg. 6).
Pole Mount: Refer to Fig.3 -8, pg. 7
Note: All inlets for conduit fittings should be on the bottom of the enclosure.
5. Mount backplane in enclosure with hardware.
6. To facilitate wire entry utilize weather tight NEMA rated connectors (supplied), bushings and cable.
NetWay4EB/4EPL Enclosure Installation:
1. Mount board/backplane in the desired location/enclosure with hardware supplied.
Installation:
1. Secure cabinet to earth ground. Connect AC power (115VAC, 60Hz / 230VAC 50/60Hz to the terminals marked [L, N] on power supply board (Fig. 1, pg. 5).
Use 14 AWG or larger for all power connections (Battery, DC output, AC input).
Keep power-limited wiring separate from non power-limited wiring (115VAC / 60Hz Input, Battery Wires).
Minimum 0.25” spacing must be provided.
CAUTION: Do not touch exposed metal parts. Shut branch circuit power before installing or servicing equipment.
There are no user serviceable parts inside. Refer installation and servicing to qualified service personnel.
2. Connect structured cables from port marked [CH1-CH4] on NetWay unit to PoE compliant camera/edge devices (Fig. 1, pg. 5).
Note: All interconnected devices must be UL Listed.
3. Connect SFP module to port marked [SFP] then connect cable to the SFP module on NetWay to the corresponding input of an SFP switch (Fig. 1, pg. 5).
4. When batteries are not used, a loss of AC will result in the loss of output voltage. When the use of stand-by batteries
is desired, they must be lead acid or gel type. Connect four (4) 12VDC batteries wired in series to terminals marked [+ BAT --- ] (Fig. 1, pg. 1),
carefully observing polarity.
5. Please ensure that the cover is secured with the provided key lock (NetWay4EX) or lockable latches are closed (NetWay4EWP/4EWPX).
www.altronix.com
- 3 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
Technical Specifications:
Parameter
Description
Four (4) - IEEE 802.3af (15W) and IEEE 802.3at (30W) compliant.
Number of Ports
One (1) - Gigabit SFP Port.
Input power requirements 115VAC, 60Hz, 3A or 230VAC 50/60Hz, 1.65A
Operating Ambient Temperature (30W): --- 30ºC to +70ºC (--- 22ºF to 158ºF).
Relative humidity: 20 to 85%, non-condensing.
Environmental Conditions
Storage Temperature: --- 30ºC to 85ºC (--- 22ºF to 185ºF).
Operating Altitude: --- 1000 to 6,561.679 ft. (--- 304.8 to 2000m).
NetWay4EX: 6.65 lbs. (3.02 kg), Shipping: 7.55 lbs. (3.42 kg).
Weights (approx.)
NetWay4EWP: 10.32 lbs. (4.68kg), Shipping: 11.7 lbs. (5.3 kg)
NetWay4EWPX: 21.5 lbs. (9.75 kg), Shipping: 23.0 lbs. (10.43 kg)
www.altronix.com
- 4 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
Typical Applications:
Fig. 1
To Stand-by
Batteries
--- DC +
+ BAT –
--- INPUT +
NetWay4EWP
Fiber
To Switch
IP PoE/PoE+
Device
SFP
CH2
CH3
CH4
IP PoE/PoE+
Device
L
G
N
CH1
IP PoE/PoE+
Device
IP PoE/PoE+
Device
115VAC/230VAC
Input
www.altronix.com
- 5 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
Wall Mount Installation
1. Mark and predrill holes in the wall to line up
with the top two keyholes in the enclosure.
2. Place unit at desired location and secure with mounting
screws (not included).
Fig. 2
www.altronix.com
- 6 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
Pole Mounting Using Optional Pole Mount Kit PMK1 (not included):
This installation should be made by qualified service personnel. This product contains no serviceable parts. PMK1 is intended for use with Altronix outdoor rated
power supplies or accessories housed in WP1, WP2, WP3 and WP4 enclosures. Brackets are designed for use with the Wormgear Quick Release Straps
(two included).
1. Thread one (1) wormgear quick release strap through the slots on the back of a mounting bracket (Fig. 7, pg. 9).
2. Once the desired height of the top Pole Mount bracket is achieved, tighten the straps down by sliding open end of the strap through the locking mechanism
on the strap, then tighten the screw with flat head screwdriver or 5/16” hex socket driver (Fig. 8, pg. 9).
Fig. 6
Fig. 4
Fig. 3
Fig. 5
3. Attach the bottom bracket to the enclosure by inserting bolts through the flange of the enclosure and into the bracket, tightening bolts
with a 7/16” hex socket (Fig. 10, pg. 10).
4. Thread the second wormgear quick release strap through the slots on the back of the bottom mounting bracket (Fig. 10, pg. 10).
5. Mount enclosure onto the top bracket by inserting bolts through flange of the enclosure and into the bracket, tightening bolts with a 7/16” hex socket (Fig. 11, pg. 10).
6. Tighten the straps of the bottom bracket down by sliding the open end of the strap through the locking mechanism on the strap, then tighten screw with
flat head screwdriver or 5/16” hex socket driver (Fig. 11/11a, pg. 10).
7. Clip excess straps.
Fig. 7: 2” to 8”(50.8mm to 203.2mm) diameter round pole
www.altronix.com
Fig. 8: 5” (127mm) square pole
- 7 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
NetWay4EX - Mechanical Drawing and Dimensions (H x W x D approx.) :
13.5” x 13” x 3.25” (342.9mm x 330.2mm x 82.55mm)
1.40”
(36mm)
4.85”
(123mm)
4.85”
(123mm)
1.40”
(36mm)
1.20”
(31mm)
3.25”
(83mm)
3.25”
(83mm)
1.20”
(31mm)
0.75”
(19mm)
12.5” (318mm)
11.0” (279mm)
1.20”
(31mm)
0.75”
(19mm)
0.9375”
(24mm)
1.40”
(36mm)
1.40”
(36mm)
5.10”
(130mm)
5.10”
(130mm)
13.0”
(330mm)
5.10”
(130mm)
6.5625”
(167mm)
0.9375”
(24mm)
www.altronix.com
- 8 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
NetWay4EPL - Mechanical Drawing and Dimensions (H x W x D approx.) :
10.75” x 8.875” x 2.375” (273.05mm x 225.42mm x 60.32mm)
8.875” (225.42mm)
8.25” (209.54mm)
0.25”
(6.35mm)
10.25”
10.75”
(260.34mm) (273.05mm)
www.altronix.com
- 9 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
NetWay4EWP - Mechanical Drawing and Dimensions (H x W x D approx.) :
13.31” x 11.31” x 5.59” (338.1mm x 287.3mm x 142mm)
1.61”
(40.894mm)
11.32” (287.528mm)
10.75” (273.05mm)
10.00” (254mm)
3.96”
(100.584mm)
8.25” (209.55mm)
13.32”
(338.328mm)
12.75”
(323.85mm)
12.00”
(304.8mm)
10.25”
(260.35mm)
13.50”
(342.9mm)
10-32 X 0.375” (9.525mm)
BRASS INSERT (X4)
10-32 X 0.25” (6.35mm)
BRASS INSERT (X2)
STAINLESS STEEL PIANO HINGE
5.60”
(142.24mm)
PADLOCK LATCH ATTACHED
WITH RIVETS (Ø 0.375” (9.52mm) PADLOCK EYE).
8.00” (203.2mm)
www.altronix.com
Ø 0.32 (8.128mm) MOUNTING HOLE
TYP. 4 PLACES
- 10 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
NetWay4EWPX - Mechanical Drawing and Dimensions (H x W x D approx.) :
17.375” x 12” x 6.5” (441.3mm x 304.8mm x 165.1mm)
0.3125’’
7.9375mm
0.5’’
12.7mm
14.875’’
377.83mm
17.375’’
441.3mm
16’’
406mm
16.75’’
425.45mm
10’’
254mm
6.5’’
165.1mm
10.875’’
276.2mm
12’’
304.8mm
4.5’’
114.3mm
www.altronix.com
- 11 -
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
Notes:
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056
website: www.altronix.com, e-mail: info@altronix.com. Lifetime Warranty, Made in U.S.A.
IINetWay4EX/NetWay4EWPE25P
www.altronix.com
- 12 -
MEMBER
NetWay4EWP / 4EWPX / 4EX / / 4EPL / 4EB
Related documents
Download