TYPE: CATALOG #: SPEC GRADE NOTES: LS Series 6 and 12 Volt Steel Enclosure Suggested Specification • Each unit comes with two (2) EF-18 heads with 9 watt high intensity incandescent lamps (standard). One or three heads available as options • Constructed of 20-gauge steel with an off-white baked enamel finish • Available with sealed, maintenance-free Nickel-Cadmium, or LeadCalcium batteries • Power Requirements: 120/277 VAC 60Hz, 0.3/0.15A • PulsePlus Charger circuitry offers 120/277 VAC 60 Hz., 0.3/0.15A (other inputs available), fused output circuit(s), dual diagnostic indicator lights, temperature compensation, sealed relay, low voltage battery disconnect, brownout protection and lock out (automatic battery connect) • Removable front panel • UL Listed. Complies with NEC, Life Safety Code and OSHA. Approved for use in the Commonwealth of Pennsylvania and New York City • 3-year full warranty, excluding lamps and fuses Supply and install the Emergi-Lite® LC Series LSC_________, LSE_________, LSM_________ or LC _________in 6 or 12 volt, single or double heads, with electrically compatible remote fixtures or exit signs as indicated on the plans. The emergency lighting unit shall be an architecturally designed, self-contained fixture including sealed, maintenance-free battery. Accessories (order as a separate item) SUFFIX DESCRIPTION Mounting bracket (cabinet A) B1 Mounting bracket (cabinet B) B2 Mounting shelves (cabinet B) MP3-EG Mounting shelves (cabinet C) MP6-EG Wire Guard (cabinet A) WG2-E Wire Guard (cabinet B & cabinet C) WG3-E Dimensions Dimensions are approximate and subject to change. TYPE LSC to be supplied with Long Life Nickel-Cadmium battery. TYPE LSE to be supplied with Long Life Pure Lead battery. TYPE LSM to be supplied with Lead Calcium battery. TYPE LC to be supplied with Lead Calcium (Immobilized Electrolyte) battery. The unit shall supply the rated load for a minimum of 90 minutes or to 871/2% of rated battery voltage. The unit shall be rated 120/277Vac, 60 Hz and be UL924 listed. The unit charger shall utilize an integrated circuit which samples the batter y in relation to its temperature, state of charge and input voltage fluctuations. The charger shall be current limited, temperature compensated, short-circuit protected and reverse polarity protected. The unit shall be furnished with an electronic lockout circuit which will connect the battery when the AC circuit is activated, and an electronic brownout circuit which will activate the unit when utility power dips below 80-85% of nominal voltage. A low voltage battery disconnect circuit shall be provided and will disconnect the load and circuitry from the battery when it reaches 871/2% of its nominal voltage. The unit shall be capable of full recharge in compliance with UL924 specifications. The unit shall be furnished with sealed dusttight relay, a test switch and dual diagnostic LED indicator lights (hi-charge and AC pilot). The cabinet shall be constructed of steel (see dimension chart for gauge) in off-white baked enamel color. A removable front panel shall be furnished to provide full access for ease of installation and servicing. A and B cabinet units shall have a universal mounting cluster. All cabinets shall be furnished with1/2” conduit knock-out, rear keyhole mounting slots (bracket or shelf available as an option) and provisions for mounting up to 3 heads on cabinet. Unit will be furnished with two EF18 lighting heads constructed of impact resistant, flame retardant thermoplastic material complete with 9 watt high intensity incandescent lamps. Fused output terminals shall be provided for ease of remote lamp connection. Every LS and LC Series unit shall be fully warranted for three years, subject to proper installation and maintenance. The unit shall be Emergi-Lite® model: . Unit Warranty* Unit equipment (except battery and lamps): 3-year limited warranty Battery Warranty* Unit batteries are warranted as follows: EF18 Cabinet Size EF9 Dimensions a b 12-3/4” c d A 14-5/8” // 13” 3-1/8” 8-1/2” B 16-3/8” // 14-3/4” 16-1/8” 5-7/16” 10-1/4” C 18-3/8” // 16-3/4” 16-1/2” 7-1/4” 12-1/4” Sealed Nickel Cadmium: 12LSC – 10year life expectancy, 5-year Full Warranty, plus 5-year pro rata warranty. Sealed Long Life Lead: 12LSE – 12-year life expectancy, 5-year Full Warranty, plus 5-year pro rata warranty. Sealed Lead Calcium (Free Electrolyte): 12LC – 12-year life expectancy, 5-year Full Warranty, plus 5-year pro rata warranty. Sealed Lead Calcium: 12LSM – 8-year life expectancy, 3-year Full Warranty, plus 3-year pro rata warranty. *Subject to proper installation and maintenance COMMERCIAL Features Furnished standard with two 9 watt High Intensity Incandescent lamps. UNIT EQUIPMENT - NO REMOTE CAPABILITY Nickel-Cadmium 6 LSC18-2 Watts to 87-1/2% of rated battery voltage* 1-1/2 hrs 2 hrs 4 hrs 4 hrs 18 12 9 6 Lead-Calcium 6 LSM18-2 12 Sealed Maintenance-Free Battery Types D.C. Voltage Model Number 12 10 7 # of Load Fuses Cabinet size 1 A 1 A SPEC GRADE Unit Rating UNIT EQUIPMENT - WITH REMOTE CAPABILITY 1-1/2 hrs Nickel-Cadmium 3 hrs 8 hrs LSC25-2 25 18 9 – 1 A 12 12LSC36-2 36 21 12 6 1 A 12 12LSC50-2 50 36 18 10 1 A 24 24LSC100-2 100 73 37 20 2 B 6 LSM27-2 27 18 10 6 1 A 6 LSM36-2 36 25 14 7 1 A 6 LSM54-2 54 37 21 12 1 A 6 LSM81-2 81 54 36 18 2 B 6 LSM110-2 110 72 40 24 2 B 6 LSM162-2 162 108 60 48 2 C 6 LSM200-2 200 144 80 48 2 C 12 12LSM36-2 36 25 14 7 1 A 12 12LSM54-2 54 37 21 12 1 A 12 12LSM110-2 110 72 40 24 2 B 12 12LSM162-2 162 108 60 36 2 C 12 12LSM220-2 220 144 80 48 2 C * National Electrical Code Specification = New York City Approved How to Order COLOR Blank= O ff white B= Black enclosure SERIES/CAPACITY LSC Series LSC18= 6V-18W Ni-Cd LSC25= 6V-25W Ni-Cd 12LSC36= 12V-36W Ni-Cd 12LSC50= 12V-50W Ni-Cd 12LSC72= 12V-72W Ni-Cd LSM Series LSM18= 6V-18W Lead-Calcium LSM27= 6V-27W Lead-Calcium LSM36= 6V-36W Lead-Calcium LSM54= 6V-54W Lead-Calcium LSM81= 6V-81W Lead-Calcium LSM110= 6V-110W Lead-Calcium LSM162= 6V-162W Lead-Calcium LSM200= 6V-200W Lead-Calcium 12LSM36= 12V-36W Lead-Calcium 12LSM54= 12V-54W Lead-Calcium 12LSM105= 12V-105W Lead-Calcium 12LSM110= 12V-110W Lead-Calcium 12LSM162= 12V-162W Lead-Calcium 12LSM220= 12V-220W Lead-Calcium # OF LAMPS -0= No head -1= 1 head -2= 2 heads -3= 3 heads HEAD STYLE LAMP TYPE/WATTAGE OPTIONS Blank= EF18 (PAR 36 plastic) 28= EF28 (PAR 36 metal) 9= EF9 (mini plastic) 10= EF10 (small plastic MR16) 150= EF150 (MR16 lamp heads) Blank_= 6V-9W and 12V-9W incandescent wedge base H_= Halogen bi-pin I_= Incandescent DC-bayonet U_= Incandescent sealed-beam** X_= Halogen sealed-beam** Z_= Incandescent wedge M_= Halogen MR16* LA= 6V-4W, MR16 LED* LG= 12V-4W, MR16 LED* LL= 24V-4W, MR16 LED* LI= 12V-5W, MR16 LED* LJ= 12V-6W, MR16 LED* Blank= No options -AD= Advanced Diagnostics (audible)* -ADNA= A dvanced Diagnostics (non-audible)* -NEX= NEXUS® wired (consult your sales representative)* -NEXRF= NEXUS® wireless (consult your sales representative)* -V= Voltmeter -A= Ammeter -CP= Cord and plug 120V only** -D1= Time Delay (5 minutes) -D2= Time Delay (10 minutes) -D3= Time Delay (15 minutes) -E= Cord and plug 277V * Available with EF10 & EF150 only ** Available with EF18 & EF28 only NOTE: For a complete list of available lamp types, please refer to the lamp data on pages 146-147 * Minimum lamp load required: 20% of unit capacity. Not available with 12V-72W Ni-Cd **Standard cord is 3 ft. Example: BLSC18-110LA-AD All information and specifications contained in this specsheet are subject to change due to engineer design, errors and omissions. Illustrations and diagrams within this specsheet may vary from actual products. 2014© Thomas & Betts Limited. All rights reserved. COMMERCIAL Lead-Calcium 2 hrs 6