CI/SfB CEILING&wall SYSTEMS Between us, ideas become reality ® Wood Concealed (35) Xy 01/2013 Wood Concealed Armstrong Wood Concealed Ceiling provides the opportunity to create a rich, natural, custom look using standard panels and grid. Available in five standard veneers and three standard panel sizes, the accessible wood panels can be easily installed to create a continuous look as well as clouds, due to high quality edge banding. Panel sizes can be mixed and matched on the same project to help create a distinctive visual. Three standard perforations are also available to enhance acoustical performance as well as design aesthetics. Armstrong wood panels are constructed using high class MDF, coated with clear UV enhanced lacquer, without the use of any solvents. The lacquer finish protects the planks from aging and sunlight. The Armstrong Wood Concealed Ceiling allows designers to create a custom look using standard panels and grid. Clean monolithic visual Multiple layout options n Large panel sizes, up to 2400mm n Hook-on panels provide safe and secure downward accessibility n Featuring a narrow 6 mm reveal visual, with edge banding. n n Veneers Ash (ASH) Oak (OAK) Red Oak (ROA) US Cherry (CHE) US Walnut (WAL) All Veneers have a matt finish. Variation between wood veneer panels may occur due to the natural characteristics of the wood and grain. sizes 1200 x 600 mm 1800 x 600 mm 2400 x 600 mm Patterns Plain Rg 3003 (3%) Rg 8013 (13%) Lg 8002 Grooves (2%) Groove size: 3 x 3 mm Installation Cross-section Ceiling void Main Runner Cross Tee 6 24 17 A 100 min. 67 Concealed Wood panel 600 / 2x 600 / 3x 600 300 Visible side 300 300 600 M M Longitudinal section Ceiling void Cross Tee Main Runner 100 43 T-bar hook Cut panel 3x pan-head screw min. 230 M = module size / A = panel length / B = panel width Item No. Designation BPCS5157G T-bar hook BPCS5158G Safety cable BPCS5159G Pan-head screw 4.8 x 16.5 mm Concealed Wood panel 17 40 24 Visible side B M 6 M Detail A Concealed Wood panels 1200 x 600 mm 1800 x 600 mm 2400 x 600 mm Detail B Security cable T-bar hook Main Runner 2x safety cable fixed on the oposite diagonal side Concealed Wood panel Detail C Prelude 24 TLX grid option Prelude 24 Main Runner T-bar hook Detail D Prelude 24 XL2 grid option Prelude 24 TLX cross tee Prelude 24 Main Runner T-bar hook Prelude 24 XL2 Cross Tee Concealed Wood panel 3x pan-head screw per T-bar hook Detail E suspension methods Suspension wire Suspension angle Suspension hanger for T-bar Quick hanger Bent T-bar hanger Nonius with threaded rod hanger LAYOUTS Standard layouts 1200 x 600 mm 1800 x 600 mm 2400 x 600 mm Optional layouts Staggered 1200 x 600 mm Staggered 1800 x 600 mm Staggered 2400 x 600 mm Combined modules 1200 x 600 mm & 1800 x 600 mm 1800 x 600 mm & 2400 x 600 mm 600 600 600 600 600 600 600 600 600 600 600 600600 600 600 600 600 600 600 600 Grid layout 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 600 Prelude 24 Main Runner Prelude 24 TLX / XL2 Cross Tee Concealed Wood panel 1200 x 600 mm & 2400 x 600 mm Range Prelude 24 CS 5145 M CS 5146 M CS 5147 M CS 5148 M CS 5149 M CS 5150 M CS 5151 M CS 5152 M CS 5153 M CS 5154 M CS 5155 M CS 5156 M Performance Light reflectance EN ISO 7742-2 & 3 Veneers Ash Oak Red Oak US Cherry US Walnut Plain 57% 30% 34% 29% 14% Perforated Rg 3003 54% 30% 33% 28% 14% Perforated Rg 8013 49% 26% 30% 23% 12% Perforated Lg 8002 Grooves 54% 30% 33% 28% 16% The light reflectance values shown above are the results of testing, however, due to the natural variation in wood veneers there may be some small deviation from these published values. Sound absorption 500 1000 2000 4000 Hz 0.10 0.05 0.10 0.15 aP 0.40 0.30 0.30 0.25 aP 0.85 0.70 0.65 0.60 aP 1.0 0.8 0.60 0.45 0.40 0.35 aP 0.6 0.4 0.2 0 125 250 500 1 000 2 000 4 000 Octave Band Centre Frequency (Hz) aP PEFC/10-31-1427 NRC 125 250 • Veneers Plain 0.10(L) 0.10 0.30 0.15 • Veneers Rg 3003 (3%) 0.35(L) 0.35 0.45 0.45 • Veneers Rg 8013 (13%) 0.70(L) 0.75 0.55 0.80 • Veneers Lg 8002 Grooves (2%) 0.45(L) 0.50 0.45 0.60 Sound Absorption Class = up to Class C Armstrong Building Products aw EN ISO 354 & EN ISO 11654 Perforated tiles have an acoustic fleece on the rear. EEA EN 13501-1 l = 0.12 W/m K Euroclass B-s2, d0 R.C.S. Besançon B 784 131 575 Dimensions 1200 x 600 x 17 mm 1800 x 600 x 17 mm 2400 x 600 x 17 mm 1200 x 600 x 17 mm 1800 x 600 x 17 mm 2400 x 600 x 17 mm 1200 x 600 x 17 mm 1800 x 600 x 17 mm 2400 x 600 x 17 mm 1200 x 600 x 17 mm 1800 x 600 x 17 mm 2400 x 600 x 17 mm PAS 1204 Patterns Plain Plain Plain Rg 3003 Rg 3003 Rg 3003 Rg 8013 Rg 8013 Rg 8013 Lg 8002 Grooves Lg 8002 Grooves Lg 8002 Grooves Printed in E.C. on chlorine free paper from sustainable resources. Concealed ≤70 % RH 14 kg/m2 EN 12667 & ISO 8301 Advisory note: It is very important that Armstrong Wood panels are climatised prior to installation. Relative humidity between 25% and 70% and temperatures between 10°C and 30˚C must be maintained throughout the life of the product. Please contact the Armstrong Technical Sales group for further details. All product specifications are subject to modifications without prior notice. www.armstrong.eu