600-Volt Secondary Bus Enclosure with Current Transformers Three-Phase – Pad-Mounted – Outdoor Front and rear doors for easy access Current Transformer provisions accept ABB SCL, ABB SCM & GE JAD-0C CTs 340-067 Page 1 2016 Corrosion proof nameplate is located to provide easy access for the operator Nonferrous hardware for long life Cross-kinked roof prevents standing moisture Nontracking self-scouring ELRIM cycloaliphatic epoxy insulators Accepts NEMA Standard 2-hole and 4-hole lugs back-to-back Three Phase Aluminum bus standard Copper bus optional Heavy duty 11-gauge steel enclosure is all-welded construction for long life Neutral Bus without Current Transformer provisions Removable lift provisions with blind holes for tamper resistance Stainless steel hinges are welded to the door and the enclosure – 0.375" pins are standard Ground lugs on each wall of the enclosure accept #6 - #2/0 ground cable Door-holder rods are stainless steel and hold the door open 100 degrees or 140 degrees Overlapping door and enclosure flanges - with other features - provide tamper resistance to meet national and regional standards Coordinated padlock and hex-head or optional penta-head bolt (top and bottom) provides bolted door security with visual confirmation by supervisory personnel. Security bolt is made captive with a stainless steel washer compressed to an oval shape to severely discourage removal. Open bottom and bus arrangement allows access to all cables for easy installation and maintenance Superlife finish includes phosphatizing, rust-inhibiting epoxy primer and Pad-Mount Green (Munsell 7GY 3.29/1.5) polyurethane top coat over 5 mils dry Optional Color: Grey (Munsell 5BG 7.0/0.4) Elliott Industries, Inc. © Copyright 2016 Bulletin 1509 Hamilton Road Phone 318-746-3296 ENCLOSURE OPTIONS: 1) 0.125" #5052H32 Aluminum 2) 12-gauge #304L Stainless Steel Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Three-Phase – Pad-Mounted – Outdoor Bulletin 340-067 Page 2 2016 Bus Selection Information Ø 0.5625" Holes Typical 10.875" 5.875" 2.125" 0.25"-20 Tapped Holes Supplied in 42"W x 42"D Enclosure - See Pages 4 & 5 Standard Bus: 1.75" 1.25" SCL, SCM or JAD-0C with Primary Bar 1.75" 1.75" 0.75" Ø 0.5625" Holes Typical 10.875" 5.875" 2.125" 0.25"-20 Tapped Holes Four Single 0.25" x 12" Aluminum Bus 2,100/2,500 Amp at 30/45 degree C rise over 40 degree C Ambient 1.75" 1.75" 0.625" 1.75" 1.75" 0.75" 0.25"-20 Tapped Holes Four Sets: 1 - 0.25" x 12" and 1 - 0.25" x 8" Aluminum Bus 2,700/3,400 Amp at 30/45 degree C rise over 40 degree C Ambient 1.75" 1.75" SCL, SCM or JAD-0C with Primary Bar 10.875" 5.875" 2.125" 0.25"-20 Tapped Holes Four Sets: 2 - 0.25" x 12" Aluminum Bus 3,200/4,000 Amp at 30/45 degree C rise over 40 degree C Ambient 1.75" 1.75" Ø 0.5625" Holes Typical 0.25"-20 Tapped Holes Four Sets: 1 - 0.25" x 12" and 1 - 0.25" x 8" Copper Bus 3,600/4,500 Amp at 30/45 degree C rise over 40 degree C Ambient Alternate Bus: Four Sets: 2 - 0.25" x 12" Copper Bus 4,250/5,300 Amp at 30/45 degree C rise over 40 degree C Ambient Supplied in 66"W x 66"D Enclosure - See Pages 12 & 13 Standard Bus: 1.75" Four Sets: 2 - 0.25" x 12" and 1 - 0.25" x 10" Aluminum Bus 3,750/4,650 Amp at 30/45 degree C rise over 40 degree C Ambient 1.75" 1.75" Elliott Industries, Inc. © Copyright 2016 Alternate Bus: SCL, SCM or JAD-0C with Primary Bar 10.875" 5.875" 2.125" 0.625" 1.75" 1.75" 0.75" Four Single 0.25" x 12" Copper Bus 2,800/3,400 Amp at 30/45 degree C rise over 40 degree C Ambient Supplied in 60"W x 60"D Enclosure - See Pages 10 & 11 Standard Bus: 1.75" 0.625" 1.75" 1.75" 0.75" Alternate Bus: Supplied in 54"W x 54"D Enclosure - See Pages 8 & 9 Standard Bus: 1.75" Ø 0.5625" Holes Typical Four Single 0.25" x 10" Copper Bus 2,400/2,800 Amp at 30/45 degree C rise over 40 degree C Ambient SCL, SCM or JAD-0C with Primary Bar 10.875" 5.875" 2.125" 0.625" 1.75" 1.75" 0.75" Alternate Bus: Supplied in 48"W x 48"D Enclosure - See Pages 6 & 7 Standard Bus: 1.75" Ø 0.5625" Holes Typical Four Single 0.25" x 10" Aluminum Bus 1,800/2,100 Amp at 30/45 degree C rise over 40 degree C Ambient SCL, SCM or JAD-0C with Primary Bar 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 Alternate Bus: Four Sets: 2 - 0.25" x 12" and 1 - 0.25" x 10" Copper Bus 5,000/6,200 Amp at 30/45 degree C rise over 40 degree C Ambient sales@elliott-industries.com www.elliott-industries.com Current ansformer Bulletin 600-Volt Secondary Bus Enclosure with Current Transformers 340-067 Page 3 Three-Phase – Pad-Mounted – Outdoor 2016 Current Transformer Information See Page 15 for Ratios and Catalog Numbers SCL JAD-0C SCM 0.56 Dia. Hole 4 Total #10-32 Term. Stud 2 Total 0.56 Dia. Hole 4 Total X2 #10-32 Term. Stud 2 Total X2 X1 Mounting Holes for 1/2" tubular spacers (4) X1 NAMEPLATE Nameplate H1 5.75 Dia. 8.5" 8.92" HI 5.75 Dia. 8.5" 8.92" 5.75 Dia. 8.5" Primary polarity 9.875" HI 6.75" 6.75" 6.75" 4.25" 4.25" 4.25" 6.75" 8.5" 0.875" 0.875" 6.75" 8.5" 2.125" 1.06" 6.75" 8.5" 2.27" Removable Primary Bus Bars are supplied with all Bus Enclosures 0.25"-20 S.S. Hex Nut S.S. Lock washer Current Transformer End Cap for Primary Bus Bar Assembly Primary Bus Bar Grip Ring Spacer Tap 0.25"-20 End Cap for Primary Bus Bar Assembly 3" 1.6875" Tap 0.25"-20 #10-32 S.S. Phillips Head Screws 0.25"-20 x 2.75" S.S. Hex Head Bolts Removable Primary Bus Bar Assembly for SCL, SCM, and JAD-0C Current Transformers Primary Bus Bar Can be ordered from GE with transformers - specify 10.875" Primary Bar or to order end caps with hardware from Elliott - specify Elliott #PBA Assembly Grip Ring Spacer Tap 0.25"-20 3" 1.6875" Tap 0.25"-20 #10-32 S.S. Phillips Head Screws Elliott Industries, Inc. © Copyright 2016 End Cap for Primary Bus Bar Assembly 0.25"-20 x 2.75" S.S. Hex Head Bolts GE End Cap Two (2) Required per Current Transformer 1509 Hamilton Road Phone 318-746-3296 Elliott End Cap Two (2) Required per Current Transformer Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Bulletin 340-067 Three-Phase – Pad-Mounted – Outdoor Page 4 2016 42" "C" 2 CL "C" "C" 2 4" Min. Typical Cable Training Dim. "C" - Measure in the Field Enclosure 2.25" X 2.25" Galv. Square Washer Ø.5" Anchor Bolts 1.5" 19.375" 42" 3" Min. Concrete Pad 19.375" 3" Min. 20" Alternate #1 20" 20" 14" 42" CL Bottom Open Enclosure Elliott Anchor Bracket #6102-A81-7 Ø.5" Anchor Bolts 14" 20" 1.5" Concrete Pad Ø 0.75" Typical Alternate #2 Anchor Bolt Locations Section BB and Typical Pad Dimensions Catalog Number Dim. "C" ESBE-0.6-331-CT-42W42D-36H-D87231 ESBE-0.6-331-CT-42W42D-42H-D87231 ESBE-0.6-331-CT-42W42D-48H-D87231 ESBE-0.6-331-CT-42W42D-54H-D87231 Measure in the Field Measure in the Field Measure in the Field Measure in the Field Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Bulletin 600-Volt Secondary Bus Enclosure with Current Transformers 340-067 Page 5 Three-Phase – Pad-Mounted – Outdoor 42" 42" 2016 Elliott Apparatus Insulators A Provision for Padlock and Security Bolt, Top and Bottom H1 9" 9" 4.5" 4.5" "A" CL "A" 1,000 Amp CT has One Primary Bars 2,000 Amp CT has Two Primary Bars "B" Two Ground Provisions Each Side B B A Front View Rear View Opposite Hand Section AA Door Removed 0.5625" Holes Typical Ø 42" 10.875" 5.875" 2.125" 0.25"-20 Tapped Holes 1.75" 1.25" 38" 1.75" 1.75" 40" 0.75" SCL, SCM or JAD-0C with Primary Bar Split Bus Detail 40" Standard Bus: 38" 42" CL Four Single 0.25" x 10" Aluminum Bus 1,800/2,100 Amp at 30/45 degree C rise over 40 degree C Ambient Bottom Open Alternate Bus: Ø Four Single 0.25" x 10" Copper Bus 2,400/2,800 Amp at 30/45 degree C rise over 40 degree C Ambient 0.75" Typical Section BB Catalog Number Dim. "A" Dim. "B" ESBE-0.6-331-CT-42W42D-36H-D87231 ESBE-0.6-331-CT-42W42D-42H-D87231 ESBE-0.6-331-CT-42W42D-48H-D87231 ESBE-0.6-331-CT-42W42D-54H-D87231 36" 23.375" 42" 29.375" 48" 35.375" 54" 41.375" Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Bulletin 340-067 Three-Phase – Pad-Mounted – Outdoor Page 6 2016 48" "C" 2 CL "C" "C" 2 4" Min. Typical Cable Training Dim. "C" - Measure in the Field Enclosure 22.375" 48" 2.25" X 2.25" Galv. Square Washer Ø.5" Anchor Bolts 3" Min. 1.5" 22.375" Concrete Pad 3" Min. 23" Alternate #1 23" 23" 17" 48" CL Enclosure Elliott Anchor Bracket #6102-A81-7 17" Bottom Open Ø.5" Anchor Bolts 23" 1.5" Concrete Pad Ø 0.75" Typical Anchor Bolt Locations Alternate #2 Section BB and Typical Pad Dimensions Catalog Number Dim. "C" ESBE-0.6-331-CT-48W48D-36H-D2001048 ESBE-0.6-331-CT-48W48D-42H-D2001048 ESBE-0.6-331-CT-48W48D-48H-D2001048 ESBE-0.6-331-CT-48W48D-54H-D2001048 Measure in the Field Measure in the Field Measure in the Field Measure in the Field Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Bulletin 600-Volt Secondary Bus Enclosure with Current Transformers 340-067 Page 7 Three-Phase – Pad-Mounted – Outdoor 48" 48" Elliott Apparatus Insulators A H1 9" Provision for Padlock and Security Bolt, Top and Bottom 9" 4.5" 4.5" 2016 "A" CL "A" 2,000 Amp CT has Two Primary Bars 3,000 Amp CT has Three Primary Bars "B" Two Ground Provisions Each Side B B A Front View Rear View Opposite Hand Section AA Door Removed 10.875" 5.875" 2.125" Ø 0.5625" Holes Typical 0.25"-20 Tapped Holes 48" 1.75" 1.75" 1.75" 44" 0.625" 1.75" 1.75" 0.75" 46" SCL, SCM or JAD-0C with Primary Bar Split Bus Detail 46" 44" 48" CL Standard Bus: Four Single 0.25" x 12" Aluminum Bus 2,100/2,500 Amp at 30/45 degree C rise over 40 degree C Ambient Bottom Open Alternate Bus: Ø Four Single 0.25" x 12" Copper Bus 2,800/3,400 Amp at 30/45 degree C rise over 40 degree C Ambient 0.75" Typical Section BB Catalog Number Dim. "A" Dim. "B" ESBE-0.6-331-CT-48W48D-36H-D2001048 ESBE-0.6-331-CT-48W48D-42H-D2001048 ESBE-0.6-331-CT-48W48D-48H-D2001048 ESBE-0.6-331-CT-48W48D-54H-D2001048 36" 21.375" 42" 27.375" 48" 33.375" 54" 39.375" Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Bulletin 340-067 Three-Phase – Pad-Mounted – Outdoor Page 8 2016 54" CL "C" 2 "C" "C" 2 4" Min. Typical Cable Training Dim. "C" - Measure in the Field Enclosure 25.375" 54" 2.25" X 2.25" Galv. Square Washer 3" Min. Ø.5" Anchor Bolts 25.375" 1.5" 3" Min. 26" Concrete Pad 26" Alternate #1 26" 20" CL 54" Bottom Open Enclosure Elliott Anchor Bracket #6102-A81-7 20" Ø.5" Anchor Bolts 26" 1.5" Concrete Pad Ø 0.75" Typical Alternate #2 Anchor Bolt Locations Section BB and Typical Pad Dimensions Catalog Number Dim. "C" ESBE-0.6-331-CT-54W54D-36H-D2003218 ESBE-0.6-331-CT-54W54D-42H-D2003218 ESBE-0.6-331-CT-54W54D-48H-D2003218 ESBE-0.6-331-CT-54W54D-54H-D2003218 Measure in the Field Measure in the Field Measure in the Field Measure in the Field Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Bulletin 600-Volt Secondary Bus Enclosure with Current Transformers 340-067 Page 9 Three-Phase – Pad-Mounted – Outdoor 54" 54" 2016 Elliott Apparatus Insulators A H1 10" 5" 10" 5" "A" CL "A" 3,000 Amp CT has Three Primary Bars 4,000 Amp CT has Four Primary Bars "B" B Provision for Padlock and Security Bolt, Top and Bottom Two Ground Provisions Each Side B A Front View Rear View Opposite Hand Section AA Door Removed 54" Ø 0.5625" Holes Typical 10.875" 5.875" 2.125" 0.25"-20 Tapped Holes 1.75" 1.75" 1.75" 50" 52" 0.625" 1.75" 1.75" 0.75" SCL, SCM or JAD-0C with Primary Bar Split Bus Detail 52" 50" 54" CL Standard Bus: Four Sets: 1 - 0.25" x 12" and 1 - 0.25" x 8" Aluminum Bus 2,700/3,400 Amp at 30/45 degree C rise over 40 degree C Ambient Bottom Open Alternate Bus: Ø Four Sets: 1 - 0.25" x 12" and 1 - 0.25" x 8" Copper Bus 3,600/4,500 Amp at 30/45 degree C rise over 40 degree C Ambient 0.75" Typical Section BB Catalog Number Dim. "A" Dim. "B" ESBE-0.6-331-CT-54W54D-36H-D2003218 ESBE-0.6-331-CT-54W54D-42H-D2003218 ESBE-0.6-331-CT-54W54D-48H-D2003218 ESBE-0.6-331-CT-54W54D-54H-D2003218 36" 21.375" 42" 27.375" 48" 33.375" 54" 39.375" Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Bulletin 340-067 Three-Phase – Pad-Mounted – Outdoor Page 10 2016 Cable Training and Anchor Bolt Locations 60" CL "C" 2 "C" "C" 2 4" Min. Typical Cable Training Dim. "C" - Measure in the Field 28.375" 60" Enclosure 3" Min. 2.25" X 2.25" Galv. Square Washer 28.375" Ø.5" Anchor Bolts 1.5" 3" Min. 29" Concrete Pad 29" 29" Alternate #1 23" 60" CL Enclosure Bottom Open Elliott Anchor Bracket #6102-A81-7 23" Ø.5" Anchor Bolts 29" 1.5" Concrete Pad Ø 0.75" Typical Alternate #2 Anchor Bolt Locations Section BB and Typical Pad Dimensions Catalog Number Dim. "C" ESBE-0.6-331-CT-60W60D-36H-D2010148 ESBE-0.6-331-CT-60W60D-42H-D2010148 ESBE-0.6-331-CT-60W60D-48H-D2010148 ESBE-0.6-331-CT-60W60D-54H-D2010148 Measure in the Field Measure in the Field Measure in the Field Measure in the Field Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Bulletin 600-Volt Secondary Bus Enclosure with Current Transformers 340-067 Page 11 Three-Phase – Pad-Mounted – Outdoor 60" 60" 2016 Elliott Apparatus Insulators A H1 12" 6" 12" 6" "A" CL "A" 3,000 Amp CT has Three Primary Bars 4,000 Amp CT has Four Primary Bars "B" B Provision for Padlock and Security Bolt, Top and Bottom Two Ground Provisions Each Side B A Front View Rear View Opposite Hand Section AA Door Removed 60" 10.875" 5.875" 2.125" Ø 0.5625" Holes Typical 0.25"-20 Tapped Holes 1.75" 1.75" 56" 1.75" 58" 0.625" 1.75" 1.75" 0.75" SCL, SCM or JAD-0C with Primary Bar Split Bus Detail 58" 56" 60" CL Standard Bus: Four Sets: 2 - 0.25" x 12" Aluminum Bus 3,200/4,000 Amp at 30/45 degree C rise over 40 degree C Ambient Bottom Open Alternate Bus: Four Sets: 2 - 0.25" x 12" Copper Bus 4,250/5,300 Amp at 30/45 degree C rise over 40 degree C Ambient Ø 0.75" Typical Section BB Catalog Number Dim. "A" Dim. "B" ESBE-0.6-331-CT-60W60D-36H-D2010148 ESBE-0.6-331-CT-60W60D-42H-D2010148 ESBE-0.6-331-CT-60W60D-48H-D2010148 ESBE-0.6-331-CT-60W60D-54H-D2010148 36" 21.375" 42" 27.375" 48" 33.375" 54" 39.375" Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Bulletin 340-067 Three-Phase – Pad-Mounted – Outdoor Page 12 2016 Cable Training and Anchor Bolt Locations 66" CL "C" 2 "C" "C" 2 4" Min. Typical Cable Training Dim. "C" - Measure in the Field 66" 31.375" 3" Min. 31.375" 3" Min. 32" Enclosure 2.25" X 2.25" Galv. Square Washer Ø.5" Anchor Bolts 32" 1.5" Concrete Pad 32" 26" Alternate #1 66" CL Enclosure Bottom Open Elliott Anchor Bracket #6102-A81-7 26" 32" Ø.5" Anchor Bolts 1.5" Concrete Pad Ø 0.75" Typical Alternate #2 Anchor Bolt Locations Section BB and Typical Pad Dimensions Catalog Number Dim. "C" ESBE-0.6-331-CT-66W66D-36H-D2011103 ESBE-0.6-331-CT-66W66D-42H-D2011103 ESBE-0.6-331-CT-66W66D-48H-D2011103 ESBE-0.6-331-CT-66W66D-54H-D2011103 ESBE-0.6-331-CT-66W66D-60H-D2011103 Measure in the Field Measure in the Field Measure in the Field Measure in the Field Measure in the Field Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com Bulletin 600-Volt Secondary Bus Enclosure with Current Transformers 340-067 Page 13 Three-Phase – Pad-Mounted – Outdoor 66" 2016 66" A CL H1 13" 6.5" "A" 13" 6.5" "B" 4,000 Amp CT has Four Primary Bars 5,000 Amp CT has Five Primary Bars Ground Provision Each Side B Provision for Padlock and Security Bolt, Top and Bottom B A Front View Rear View Opposite Hand Section AA Door Removed 66" Ø 0.5625" Holes Typical 62" 10.875" 5.875" 2.125" 0.25"-20 Tapped Holes 1.75" 64" 1.75" 1.75" 0.625" 1.75" 1.75" 0.75" 64" 62" SCL, SCM or JAD-0C with Primary Bar Split Bus Detail 66" CL Standard Bus: Four Sets: 2 - 0.25" x 12" and 1 - 0.25" x 10" Aluminum Bus 3,750/4,650 Amp at 30/45 degree C rise over 40 degree C Ambient Bottom Open Alternate Bus: Ø Four Sets: 2 - 0.25" x 12" and 1 - 0.25" x 10" Copper Bus 5,000/6,200 Amp at 30/45 degree C rise over 40 degree C Ambient 0.75" Typical Section BB Catalog Number Dim. "A" Dim. "B" ESBE-0.6-331-CT-66W66D-36H-D2011103 ESBE-0.6-331-CT-66W66D-42H-D2011103 ESBE-0.6-331-CT-66W66D-48H-D2011103 ESBE-0.6-331-CT-66W66D-54H-D2011103 ESBE-0.6-331-CT-66W66D-60H-D2011103 36" 21.375" 42" 27.375" 48" 33.375" 54" 39.375" 60" 45.375" Secondary Bus Enclosures are available in other size enclosures, bus ratings and current transformer provisions. If you do not find a model to fit your need, please contact our representative or the factory. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Three-Phase – Pad-Mounted – Outdoor Bulletin 340-067 Page 14 2016 Typical Specification - Page 1 of 2 General The secondary bus enclosure with current transformers shall be 600 volt class, suitable for use on systems that do not exceed 600 volts to ground (nor 1000 volts phase-to-phase). Each phase bus shall be designed for and include (or accept) a 600 volt class current transformer (ABB SCL, ABB SCM, GE JAD-0C or equal). The phase bus(es) and the full-size neutral bus shall be constructed for connection to the electrical system with two-hole and/or four-hole NEMA standard bolt-on cable-terminal lugs (terminal lugs shall be supplied by the user). Tamper resistance shall meet the Enclosure Security requirements of IEEE Standard C57.12.28 (Pad-Mounted Equipment—Enclosure Integrity) to resist unauthorized entry, protect authorized and unauthorized persons, and provide positive safety features when installed in areas accessible to the general public. The enclosure shall be constructed for outdoor installation in areas subject to heavy precipitation and in areas of windblown contamination. The equipment shall be completely assembled prior to shipment. Enclosure Construction The enclosure shall be tamper-resistant, all-welded construction utilizing 11-gauge minimum sheet steel. Corner plates and braces shall be used as necessary to assure rigidity. The enclosure top shall be cross-kinked to provide watershed and rigidity. The enclosure shall be open bottom with a 1-inch flange inside, all around. The door(s) shall be furnished with a stainless steel door holder that will latch the door open 100 degrees and 140 degrees and resist accidental closing. Door(s) shall be provided with provisions for padlocking and a recessed hex-head (or penta-head) security bolt to prevent unauthorized entry (coordinated to prevent installation of the padlock until the security bolt is tightened when closing the door(s) and to prevent a wrench from operating the security bolt until the padlock is removed when opening the door(s)). The security bolt shall be made captive with a stainless steel washer compressed to an oval shape to severely discourage removal. Hinges shall be stainless steel (with stainless steel pins not less than 0.3125-inch diameter) and shall be welded to both the enclosure and the door(s) to maintain door alignment for the life of the equipment. The enclosure shall be nonventilated to minimize the entrance of airborne contamination, insects, rodents or reptiles. The protective finish shall include necessary grinding, cleaning and phosphatizing, two-component rustinhibiting epoxy primer and a Pad-Mount Green two-component polyurethane top coat finish (Munsell color 7GY 3.29/1.5). The primer and top coat shall be electronically monitored during application to insure proper ratio and mixing of each component. Total average thickness of paint (after curing) shall be not less than 5 mils. The protective coating shall meet the Enclosure Coating System requirements of IEEE Standard C57.12.28 (Pad-Mounted Equipment—Enclosure Integrity). Removable lift provisions, adequate to withstand handling with normal utility equipment, shall be provided on the outside of Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 the enclosure. Threaded openings for lift provision bolts shall be blind holes to prevent the entrance of wire or other foreign objects into the enclosure when lift provisions are removed. Bus and Bus Mountings Bus shall be aluminum (Alternate #1—bare copper, Alternate #2—tin-plated copper) with all burrs and sharp corners removed prior to installation. It shall be punched with 0.5625-inch diameter holes on 1.75-inch centers to accommodate both two-hole and four-hole NEMA standard cable-terminal lugs. The bus shall be constructed to allow installation and provide support for 600 volt class current transformers (ABB SCL, ABB SCM, GE JAD-0C or equal) utilizing the correct number of 0.25-inch by 4-inch primary bars with 10.875-inch outboard centerline mounting holes. The current transformers shall be mounted in a manner that will allow installation or field replacement without the removal of cables that may be bolted to the bus. A minimum of two insulators shall be provided for each bus assembly. The insulators shall be cycloaliphatic epoxy and shall be mounted in a manner that will allow field replacement with standard tools without removal of cables that may be bolted to the bus. Insulators and bus bars shall be installed with stainless steel mounting hardware to provide long life and reduced maintenance. All components shall be arranged to allow visual inspection without de-energizing or removing the equipment from service. Current Transformers Alternate 1: Current Transformers shall be supplied and installed by the user. Alternate 2: Current Transformers specified by the user shall be supplied and installed by the manufacturer. Voltage Transformers Alternate 1: Voltage Transformers are not required. Alternate 2: When specified, a mounting plate shall be provided for Voltage Tranformers supplied and installed by the user. Alternate 3: When specified, a mounting plate shall be provided for Voltage Transformers supplied and installed by the manufacturer. Secondary Wiring Alternate 1: Secondary wiring shall be supplied and installed by the user. Alternate 2: Secondary wiring shall be #10 THW/XHHW stranded-copper wire connecting the instrument transformer secondary to the 10-Terminal Test Switch and 13-Terminal Meter Socket installed on the right-hand exterior wall of the Secondary Bus Enclosure (when facing the front door). The secondary wiring shall be color-coded as specified by the user (or the factory color code when the user does not specify a color code). Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Three-Phase – Pad-Mounted – Outdoor Bulletin 340-067 Page 15 2016 Typical Specification - Page 2 of 2 SCL Barrier Option When Option B11 is specified, a clear polycarbonate barrier not less than 0.25-inch nominal thickness shall be provided (and installed) that divides the utility access compartment from the consumer access compartment. The clearance from the barrier to each wall shall not exceed two inches. The clearance from the barrier to the bottom of the enclosure shall not exceed twelve inches. Openings to accommodate bus bars extending through the barrier shall provide not less than 0.5-inch clearance nor more than 2-inch clearance from the bus bar in every direction. Grounding Provisions Four high-conductivity bronze eyebolt-type ground lugs, which accept #6 through #2/0 copper conductor, shall be installed on the inside walls of the enclosure (located on each side of each door opening in an accessible position as shown on the drawings). Accessory Equipment A corrosion proof nameplate with permanent thermal transfer printing shall be installed inside one door on the cable compartment. It shall be located at the top corner farthest from the cables when the door is open. The nameplate will provide Type of Equipment, Model Number, Amps Continuous, kV Maximum, BIL, Serial Number, Job Number, Date Manufactured and Weight of Equipment. When specified, one “Warning - Keep Out! - Hazardous Voltage” sign, Elliott #7201-W2003-316, shall be provided on the outside of each door. When specified, four anchor-bolt brackets, Elliott #6102-A81-7 or approved equal, shall be supplied with each secondary bus enclosure to provide a means of clamping the equipment to the concrete pad. Primary Amps 200 300 400 600 800 1000 1200 1500 2000 2500 3000 4000 Style Number 7526A81G01 7526A81G02 7526A81G03 7526A81G04 7526A81G05 7526A81G06 7526A81G07 7526A81G08 7526A81G09 7526A81G10 7526A81G11 7526A81G12 Rating Factor 30°C 55°C 2.0 1.5 2.0 1.5 2.0 1.5 2.0 1.5 2.0 1.5 1.5 1.0 1.5 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 SCM Primary Amps 200 300 400 500 600 800 1000 1200 1500 1600 2000 2500 3000 4000 Style Number 7525A36G01 7525A36G02 7525A36G03 7525A36G04 7525A36G05 7525A36G06 7525A36G07 7525A36G08 7525A36G09 7525A36G10 7525A36G11 7525A36G12 7525A36G13 7525A36G14 Rating Factor 30°C 55°C 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.33 1.0 1.0 0.5 Packaging Each secondary bus enclosure shall be bolted to a solid-top wood pallet (to prevent the forks of a forklift truck from entering the open bottom of the equipment) to prevent hidden damage. The equipment shall be wrapped with 0.125-inch thick polyethylene foam or other suitable material to minimize damage to the finish during shipment. Drawings When specified, drawings shall be furnished for each secondary bus enclosure that include: 1) enclosure dimensions and location of components. 2) proposed cable-training layout and dimensions. 3) proposed pad dimensions and location of anchor bolts. Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 JAD-0C Current Ratio in Amperes Pri : Sec 200:5 300:5 400:5 500:5 600:5 800:5 1000:5 1200:5 1500:5 2000:5 2500:5 3000:5 4000:5 Catalog Number Continuous(with Round Window; thermal-current without Rating Factor Mounting Base) 30°C Ambient 750X120240 4.0 750X120241 4.0 750X120242 4.0 750X120243 4.0 750X120244 3.0 750X120001 3.0 750X120002 2.0 750X120003 2.0 750X120180 3.0 750X120005 2.0 750X120006 1.5 750X120007 1.5 750X120008 1.5 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com 600-Volt Secondary Bus Enclosure with Current Transformers Bulletin 340-067 Three-Phase – Pad-Mounted – Outdoor Page 16 2016 Information needed to provide a Quotation for a Secondary Bus Enclosure with Current Transformers Catalog Number: Enclosure: Standard 11-gauge Steel Hex Head Security Bolts □ □ 0.125” Aluminum Penta Head Security Bolts □ □ 12-gauge Stainless Steel □ Actual Secondary Voltage (Optional): Without CTs: □ With CTs: Preferred Brand of Transformers: □ CT Ratio ABB □ :5 GE □ CT Style/Catalog Number: Either Without VTs: □ □ With VTs: □ VT Ratio :1 Other VT Style/Catalog Number: Your Name, Company Name, Complete Postal Address and E-mail Address: Name and Complete Shipping Address: Project Name: NOTE: Single phase and two phase Secondary Bus Enclosures are available. Contact our representative or the factory. If you do not find the design you need PLEASE CONTACT our REPRESENTATIVE or the FACTORY Elliott Industries, Inc. © Copyright 2016 1509 Hamilton Road Phone 318-746-3296 Bossier City, LoUiSiAna 71111 Fax 318-741-1127 sales@elliott-industries.com www.elliott-industries.com