Communication Module CM

advertisement
PG L. The Value
Provider for
Power Generation
Management
Communication Module
CM
Power Generation l Instrumentation & Controls
PG L. The Value
Provider for
Power Generation
Management
The Architecture
From Complete Overview to the Smallest Detail
External
Network
OT
OT
OT
OT/ET
OPC
XU
web-server
OT/DT
Terminal bus
OM
ES
DS
Plant bus
AP
AP
AP
AP
AG-F
APF
Auxiliary
APT
CM
SIMATIC
S5 / S7
IEC 60870
Modbus
FUM
FUM-F
Add
FEM
SIM-F
ET200M
PROFIBUS-DP
PROFIBUS-PA
SIM
ET200M
TELEPERM XP
Positioner
M
MCC
DP/PA
Link
AS-interface
DP/AS-i
Link
Power Generation l Instrumentation & Controls 2/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Connecting with 3rd Party PLC / DCS
Management
3rd
3rd Party
Party
Computer
Computer
Systems
Systems
3rd
3rd party
party
PLC
PLC // DCS
DCS
Externes
Netzwerk
OT
OT
OT
OT/ET
OPC
XU
web-server
OT/DT
Terminalbus
Anlagenbu
s
AP
FUM
PROFIBUS-DP
SIM
World
Standards
TELEPERM XP
FUM-F
OM
ES
AP
AP
APF
AG-F
SIM-F
DS
CM
AP Neben-SIMATIC
anlageS5 / S7 IEC 60870
Modbus
APT
Add
FEM
ET200M
AS-interface
ET200M
Stell- / M SIMO
RegelCODE
antrieb
PROFIBUSPA
DP/PA
Link
DP/AS-i
Link
Office
Connection
Power Generation l Instrumentation & Controls 3/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Connecting with 3rd Party PLC / DCS
General Features CM
Operating and Monitoring of 3rd party PLC/ DCS
through Standard TELEPERM XP HMI, including
Soft Controls 3rd party PLC/ DCS
Alarming
Logging
Archiving
Data Retrieval
Integrated into the TXP Engineering System
The Operator will not even notice, that there is
a 3rd party PLC/DCS in the background
TELEPERM XP
Power Generation l Instrumentation & Controls 4/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Connecting with 3rd Party Systems
Communication Modules - CM
OT
OT
OT/ET
Terminal bus
TELEPERM
M/ME
ES
OM
Plant bus
AP
AP
CM104
IEC 60870
Modbus
CM104
IEC 60870
Modbus
„
„
„
„
„
„
„
CS 275
SINEC H1
MODBUS*
Data Highway
IEC 60870*
GE Mark V
TCP/IP
3rd Party
System
*TELEPERM XP
Standard
TELEPERM XP
Power Generation l Instrumentation & Controls 5/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Communication Module - CM
General Features
Data exchange between TXP and various sub-systems
Conversion of sub-system data structure
to TELEPERM XP data structure
Operating and monitoring of sub-systems
with TELEPERM XP OM650
Data exchange between sub-systems
and TELEPERM XP - automation-systems
High availability achieved with hot standby
Integrated in TELEPERM XP engineering
Flexible and scalable solution
TELEPERM XP
Power Generation l Instrumentation & Controls 6/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Communication Module - CM
Engineering Features with ES 680
CM engineering functionality provided by ES680
Limited function and logic blocks
Signal assignment to sub- systems
Generation of LAN data Code
Code generation
Offline loading of engineering
data
Online loading of engineering
data (depending on subsystem protocol)
Fast parameter changes
Dynamic function charts
on ES680 and OM650
TELEPERM XP
Power Generation l Instrumentation & Controls 7/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Connecting with 3rd party PLC / DCS
References CM
Realized
physical
connections
Ethernet
RS 232, 422, 482
Protocol
Experience (1)
Modbus RTU
Modbus +
Protocol
Experience (2)
DIN 19244
CS 275
TCP/IP
Modem
STF
IEC870
Data Highway +
SIMATIC H1
3964 (R) Westinghouse
TIWAY
Texas Instruments
Every PLC / DCS is in principle connectable
TELEPERM XP
Power Generation l Instrumentation & Controls 8/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Communication Module - CM
Connected Systems
Connected Systems
CM 388/ 488
Connected Systems
CP 581 (predecessor)
Allen Bradley
Baily Infi 90
GE Mark IV, V
Westinghouse WDPF
Bentley Nevada
Noell
Modicon
AS220E,EA
Fisher Rosemount DCS
AG95,135
ABB August (fire & gas)
Honeywell
Woodward CITECH
Babcock
SCADA Sinaut LSX
Cegelec
Siemens Gas Analyser
Mitsubishi
ABB Procontrol
Hartmann & Braun
ABB Advant
Conitel
ALSTOM CEG,IDS Switchgear)
Siemens SINAUT LSA
Telegyr (Switchgear)
TELEPERM XP
Power Generation l Instrumentation & Controls 9/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Communication Module - CM
Hard- and Software Features CM104
Hardware Features
Software Features
Scalable in performance
Integrated in ES680
and I/O amounts
Engineering
(500 to 5000 tags)
Vertical and horizontal
Various physical connections
communication
(RS232, RS..., Ethernet,
Redundant communication to TXP
Modem,...)
components (PU, AP)
Single and redundant
Seamless redundancy
connection of 3rd party
switch over
PLC/DCS to TELEPERM XP
Processing of function blocks
comparable to
AP function blocks
(limited function block set)
Processing of logic blocks
(limited logic block set)
Transfer of time tagged signals, or
on board time tagging
TELEPERM XP
Power Generation l Instrumentation & Controls 10/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
PG L. The Value
Provider for
Power Generation
Management
Communication Module - CM
References - Connected Systems
Various 3rd Part Systems with a wide range of
functionality (PC, PLC, DCS)
> 300
CM 388/488 components worldwide
transferring approximately
> 40,000 signals from and to TELEPERM XP
> 200
couplings with CP 581 technology
with approximately another
> 70,000 signals processed by TELEPERM XP
Integrated,Controlled and Monitored by TELEPERM XP
TELEPERM XP
Power Generation l Instrumentation & Controls 11/11
CM 15_e, PG L61, Andreas R. Lang, 12/2002
Download