Losses in Power Electronic Converters

advertisement

Losses in Power Electronic Converters

Stephan Meier

Division of Electrical Machines and Power Electronics EME

Department of Electrical Engineering ETS

Royal Institute of Technology KTH

Teknikringen 33

SE-100 44 Stockholm

Abstract— This work is the proposed solution for Task 1,

Problem 1, in the Nordic PhD course on Wind Power, held in Smøla, Norway, between June 5-11, 2005. It discusses the converter losses and the expected costs of the back-to-back converter in a doubly-fed induction generator (DFIG) in a wind turbine application. Two different topologies of back-to-back converters are considered: A conventional two-level converter and a three-level diode-clamped converter.

and the conduction and switching losses of the semiconductor valves are approximately proportional to the converter rating and are thus decreasing with the same proportion. Also the converter filters and the filters for electromagnetic interference

(EMI) can be relaxed as they only have to be rated proportional to the converter rating, which signifies an additional large cost reduction.

I. I

NTRODUCTION

During the past few years, variable-speed wind turbines have become the dominant type among newly-installed units.

Variable-speed wind turbines are designed to achieve maximum aerodynamic efficiency over a wide range of wind speeds by continuously adapting the rotational speed of the wind turbine to the wind speed. The advantages of variable-speed wind turbines are an increased energy capture, improved power quality and reduced mechanical stress on the structure. In order to achieve variable-speed operation of the wind turbine, the electric system is getting more complicated. In recent years, mainly back-to-back converters are being used in the power conversion field for wind turbines. One solution is to use a fullscale back-to-back converter that allows full variable-speed operation of the wind turbine at the cost of a large, expensive and lossy frequency converter that is rated at nominal generator power. This configuration is used by e.g. Enercon. Another solution is to equip the variable-speed wind turbine with a

DFIG. In the DFIG wind turbine configuration, the stator of the wound-rotor induction generator is directly connected to the collection grid whereas the rotor windings are connected to a back-to-back converter over slip rings. However, this solution does only provide a limited speed range, depending on the rating of the frequency converter. A manufacturer using this configuration is e.g. Vestas.

The disadvantage of applying back-to-back converters is that these electronic devices are relatively expensive and that they introduce additional losses in the system due to the conduction and switching losses of the semiconductor valves. Recently, a new and promising technology was introduced, the multilevel converters. These type of converters promise improvements in the harmonic quality of the output voltage which is an advantage because the output filters of the system can be relaxed. But at first sight, these converters seem to increase the cost and the losses of the converters, as the number of components increases compared to the conventional two-level converters.

Therefore, this work presents a study of the losses and the expected costs of two different back-to-back converter topologies; a conventional two-level converter and a threelevel diode-clamped converter. At first, the problem is defined properly and it is determined what power flows that can be expected in both the rotor-side and the line-side voltage source converter (VSC). Then, the two considered topologies are presented and the harmonic spectrum in the respective output voltages are analyzed. Finally, a comprehensive simulation of the losses in the back-to-back converter is presented. A basic cost comparison and a summary of the main findings concludes this work.

The advantage of applying back-to-back converters in the power conversion field for wind turbines is that these converters are completely programmable and due to it, they are very versatile. This allows different control strategies to control the active power flow and to both provide reactive power to the induction generator and to achieve the compensation of reactive power on the line side. According to [1], the DFIG system has the advantage that the back-to-back converter needs only to be dimensioned with a fraction of the rated turbine power depending on the required speed range. Both the costs

II. P ROBLEM DEFINITION

The active and reactive power flows have to be determined in order to know the operation status of the back-to-back converter. Therefore, it is essential to have a generator model and a basic control system for the two VSCs. The parameters of the wound-rotor induction generator are given in p.u.-values and it is very convenient to normalize the voltage-current equations of the DFIG. In this section, it is also described how the base values for the simulation were chosen and how the

variables have to be scaled during a transformation between different reference frames.

PSfrag replacements

P r

Q s

P r

Q r

A. Generator model

In order to determine the power flows, currents and voltages for different operating conditions, i.e. for different rotor speeds, it is necessary to develop a generator model. The wound-rotor induction generator used in the DFIG system comprises a three-phase stator winding and a three-phase rotor winding, which is fed via slip rings. The used generator model is chosen according to [2], neglecting the stator and rotor transients which are not important in this context. The equations that describe the voltage-current relationship of a doubly-fed induction generator are given in p.u.-values as:

P = P s

+ P r

, Q = 0

P s

, Q s

Fig. 1.

Active and reactive power flows in the DFIG system.

TABLE I

P ARAMETERS OF THE WOUND ROTOR INDUCTION GENERATOR .

u u dr ds

=

=

R s i ds

R r i dr u qr

=

R r i qr

+ ω s

(( L sσ u qs

=

R s i qs −

ω s

(( L sσ

+ sω s

(( L rσ

+ L m

) i qs

+ L m i qr

)

+ L m

) i ds

+ L m i dr

)

+ L m

) i qr

+ L m i qs

)

− sω s

(( L rσ

+ L m

) i dr

+ L m i ds

) (1)

Parameter

Magnetising inductance L m

Stator leakage inductance L sσ

Rotor leakage inductance L rσ

Stator resistance R s

Rotor resistance R r

Stator connection

Rotor connection

Value [p.u.]

4.0

0.1

0.1

0.005

0.005

Delta

Star

In these equations, a synchronous two-phase dq-reference frame is used, that is fixed to the space vector of the stator voltage. This is a convenient alternative because the DFIG operates as a generator being fed with constant stator voltage

(in the dq-reference frame). Hence, the stator voltage and current are given for line operation of the DFIG system. The equations for determining active and reactive power flows, which are defined according to Figure 1, are given as:

P s

P r

= u

Q s

= u ds i ds dr i dr

+ u

= u qs i ds

+ u qs i qs

− qr i qr u ds i qs

Q r

= u qr i dr − u dr i qr

(2)

B. Simulation parameters and their normalization

For this work, it is assumed that the rated power S

N of the wind turbine is 1 MVA. The collection grid voltage U

N at the connection point is 690 V, which is a common choice for wind turbines. The normalized p.u.-values of the woundrotor induction generator can be found in Table I. It is very convenient to work with normalized values as the control system and the design process get independent of the actual generator size. The peak phase voltage and peak phase current are chosen as the base values, base on which the other base values of the model can be calculated as shown in Table II.

The absolute values of the stator and rotor voltages, respective currents, can be calculated as: u u s r i i s r

=

=

=

= q q u u

2 ds

2 dr q i 2 qs q i 2 qr

+ u

+ u

+ i

+ i

2 qs

2 qr

2 ds

2 dr

(3)

The power factors cos φ on the rotor and stator side are defined as: cos φ s

=

P s

S s cos φ r

=

P

S r r

=

P s p

P s

2 + Q 2 s

P r

= p

P 2 r

+ Q 2 r

=

=

P s u s · i s

P r u r · i r

(4)

It has to be considered that all quantities are given in the rotating dq-reference frame, and that the stator windings are delta connected while the rotor windings are star connected. The transformation from the stationary three-phase abc-reference frame to the rotating two-phase dq-reference frame via the stationary two-phase αβ -reference frame is given as (valid for both currents and voltages): u

α

= u

β

=

2

3 u a −

2

3

3

2 u b

1

2 u b

1

2 u c

3

2 u c

!

u d

= u

α cos θ

− u

β sin θ u q

= u

β cos θ + u

α sin θ

(5)

(6) where θ is the angular position of the rotating dq-reference frame relative to the stationary αβ -reference frame. However, the dq-quantities have to be scaled in order to get the same amplitudes as the phase quantities according to Table III [3].

2

TABLE II

M ODEL BASE VALUES .

Parameter

Base voltage U base

Base power S base

Base current I base

Base impedance Z base

Base angular frequency ω base

Equation

2

= U

N

√ 3

= S

N

=

=

=

3

2 S base

3 U base

U base

I base

2

= 2 πf

N

U base

I base

Value

1 MVA

1.18 kA

0.48

314 rad/s

TABLE III

S CALING FACTORS FOR REFERENCE FRAME TRANSFORMATIONS .

1

0.8

0.6

0.4

0.2

P s

0

−0.2

−0.3

Q r

−0.2

P

Q

P r s

−0.1

0

Slip

0.1

0.2

0.3

Fig. 2.

Active and reactive power of the rotor and stator as a function of the slip.

Parameter

Stator voltages u ds

, u qs

, u s

Rotor voltages u dr

, u qr

, u r

Stator currents i ds

, i qs

, i s

Rotor currents i dr

, i qr

, i r

Stator power P s

, Q s

, S s

Rotor power P r

, Q r

, S r

Scaling factor

3

2

3

2

3

2

2

3 √ 3

2

3

2

3

3

= 0.385

= 0.667

= 1.155

= 0.667

= 0.667

= 0.667

C. DFIG vector control

In order to get the operation conditions for different operation points, i.e. for different rotor speeds, a basic vector control scheme was implemented. Its main purpose is to guarantee stable operation and enable the independent control of active and reactive power of the back-to-back converter.

The controller is using the generator model equations derived in the previous section in the rotating dq-reference frame.

The desired rotor voltage command is determined in order to control the active and reactive rotor power by controlling the rotor currents. The line-side converter is controlling the DClink voltage and the reactive power of the total DFIG system, which is assumed to have unity power factor, i.e. it is neither absorbing nor generating reactive power ( Q = 0 ).

zero, which means that a pure DC current will flow in the rotor.

Figure 2 shows the active and reactive rotor and stator power over the required speed range. It can be noticed that the active rotor power P r is flowing through the back-to-back converter, as it cannot generate, consume or store active power (apart from the losses that inherently appear). The total active power generated by the doubly-fed induction generator is the sum of the rotor and stator active power P = P s

+ P r

. With the chosen DFIG control scheme, the active stator power is kept constant over the whole speed range while the rotor power is proportional to the slip. In contrary to the active power, the back-to-back converter can generate or consume reactive power, which is utilized in order to get unity power factor at the connection point of the wind turbine. It can be seen that the back-to-back converter operates as a generator of active power above synchronous speed and delivers active power to the grid.

At a slip of s =

0 .

3 , the wind turbine delivers rated active power to the collection grid. Contrary, below synchronous speed, the back-to-back converter by-passes active power from the grid into the rotor circuit and the active power delivered to the grid becomes approximatively half the rated power at a slip of s = 0 .

3 .

In this study, it is assumed that the mechanical rotor speed is required to have the possibility to change from 0.7 to 1.3

times the synchronous generator speed, which corresponds to a slip range between -0.3 to +0.3. The slip s of the induction generator is given as s =

ω s −

ω mech

ω s

=

ω r

ω s

, (7) where ω s is the electrical angular frequency of the stator quantities (which is constant and equal to the base angular frequency ω base

), ω mech is the mechanical angular frequency of the rotor shaft and ω r is the electrical angular frequency of the rotor quantities. This equation is valid for an induction generator with two poles (one pole pair). The number of electrical poles in the induction generator does not influence its electrical behavior but changes the requirement on the gear ratio in the gear box of the wind turbine. It can be noticed that the electrical angular rotor frequency at zero slip becomes

Figure 3 shows the rotor and stator voltages and currents over the required speed range. It can be seen that the stator voltage is as expected 1 p.u. Also the stator and rotor currents are constant over the whole speed range, while the rotor voltage is approximately proportional to the absolute value of the slip and becomes zero for zero slip.

III. C ONSIDERED TOPOLOGIES

The considered topologies for the back-to-back converter are a conventional two-level converter as shown in Figure 4 and a three-level diode-clamped converter as shown in Figure 6. The two-level topology is widely used in VSC transmission systems and in back-to-back converters in DFIG wind turbines at a wide range of power levels. Figure 5 shows the output waveform of the two-level converter which is either positive or negative. 1 p.u. voltage corresponds to half the DC-link voltage. In order to improve the quality of the voltage output, a pulse width modulation (PWM) switching

3

PSfrag replacements

1

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0

−0.3

u s u r i s i r

−0.2

−0.1

0

Slip

0.1

0.2

0.3

Fig. 4.

Conventional two-level converter.

Fig. 3.

Voltage and current of the rotor and stator as a function of the slip.

1

0.5

scheme is used that produces a waveform with a dominant fundamental component with the compromise that significant higher-order harmonics are also generated, as shown in the harmonic spectrum of the two-level converter in Figure 5.

The applied PWM switching scheme is a carrier-based control method with a switching frequency of 1050 Hz (frequency modulation ratio p = 21 ). The amplitude modulation ratio in Figure 5 is m a

= 0 .

94 , which corresponds to the operation point of the line-side VSC in the back-to-back converter.

0

−0.5

−1

0

1

0.8

0.6

0.4

0.2

0

0

2 4 6 8 10

Time [ms]

12 14 16 18 20

By splitting up the DC capacitor and the insulated gate bipolar transistor (IGBT) valves and with the help of additional diodes, a three-level diode-clamped converter as shown in

Figure 6 can be formed. The output waveform comprises three voltage levels, i.e. 1 p.u., 0, - 1 p.u. as shown in Figure 7. 1 p.u.

voltage corresponds to half the DC-link voltage that is the voltage above one of the bus-splitting capacitors. As for the two-level converter, a carrier-based PWM switching scheme with an identical frequency and amplitude modulation ratio is appplied in order to be able to compare the results with the two-level converter topology. Figure 7 shows the harmonic content in the waveform, which has a considerably lower total harmonic distortion (THD). It should be noticed that the effective switching frequency of the IGBT valves is only half the one in the two-level converter topology. This is due to the splitting of the valves and the characteristics of the control method.

10 20 30 40 50

Harmonic number

60 70 80 90 100

Fig. 5.

Output waveform and harmonic spectrum of the two-level converter.

The advantages and disadvantages of the two-, respectively three-level converter topologies can be summerized according to Table VI. The conduction and switching losses as well as the converter costs and the capacitor size are further investigated in this work.

Fig. 6.

Three-level diode-clamped converter.

TABLE IV

C OMPARISON BETWEEN TWO AND THREE LEVEL CONVERTERS .

A. Choice of components

Table V shows the characteristics of the back-to-back converters and the choice of the IGBT semiconductor components from Semikron [4] and the DC link capacitors from Evox Riva

[5]. Please refer to the corresponding datasheets for further information about the chosen components.

Characteristic

Circuitry

Two-level Three-level

Very simple More complex

Control

Capacitor size

Very simple More problematic

Small Large

IGBT duty Equal

IGBT blocking voltage Large

Different

Small (half)

Harmonic content

Switching losses

Footprint (size)

Large

High

Small

Small

Relatively low

Somewhat larger

4

1

0.5

0

−0.5

−1

0

1

0.8

0.6

0.4

0.2

0

0

2 4 6 8 10

Time [ms]

12 14 16 18 20 from the characteristic turn-on and turn-off energy ( E on

, respectively E of f

) given in the datasheets. Unfortunately, the switching losses for the antiparallel diodes are not mentioned and could therefore not be included in this study. Also the losses from the reverse recovery energy E rr have to be considered. A reverse recovery current is required in order to sweep out the excess carriers in the anti-parallel diode and allow it to block a negative polarity voltage. The switching losses are also dependent on the switched current and the device temperature.

The switching losses P sw can be calculated by summing up the switching events during a fundamental period according to

P sw

= f

X

E on

( I ce

) +

X

E of f

( I ce

) +

X

E rr

( I ce

)

(9)

10 20 30 40 50

Harmonic number

60 70 80 90 100

Fig. 7.

Output waveform and harmonic spectrum of the three-level diodeclamped converter.

TABLE V

C HOICE OF COMPONENTS .

DC link voltage

Semiconductor components [4]

IGBT module (2-level rotor-side):

IGBT module (2-level line-side):

IGBT module (3-level rotor-side):

IGBT module (3-level line-side):

Clamping diode module (3-level):

1200 V

SKM 500GA123D

SKM 400GA123D

SKM 400GB066D

SKM 300GB066D

SKKD 205F

DC link capacitors [5]

2-level (3 series-capacitors `a 400 V): PEH200VV447AM 4.7 mF

3-level (6 series-capacitors `a 200 V): PEH169RV510VM 10 mF

IV. L OSSES

The losses are calculated in Matlab under the assumption that the three-phase currents on the rotor- and line- side are perfectly sinusoidal, which can be assumed as the current ripple in average will not generate any additional losses. The total losses consist of conduction and switching losses in the

IGBT and clamping diode modules.

The conduction losses P cond depend on the on-state voltage drop across the device and the current through it. They can be calculated from the on-state threshold voltage V ce 0

, the onstate slope resistance r ce 0

, and the device current I ce according to

P cond

= f

·

Z

1 f t =0

V ce 0 ·

I ce

( t ) + r ce 0 ·

2

I ce

( t ) d t (8)

Both the on-state slope resistance and the threshold voltage depend on the device temperature and were chosen according to the typical values given in the datasheets. The switching losses consist of turn-on and turn-off losses of the IGBTs, the anti-parallel diodes and the clamping diodes in the three-phase converter topology. The switching losses can be calculated

A. Results of the loss comparison

The results of the loss comparison between the two- and three-level converter topologies is shown in Table VI. Different operation points corresponding to slip levels between -0.3 and

0.3 are investigated. The total losses are divided in switching losses, IGBT conduction losses and diode conduction losses and presented both for the rotor- and line-side converter. The conclusions from Table VI can be summerized as follows:

The total losses of the three-level converter are approximately 20 % bigger for all points of operation. This is mainly due to the dominating conduction losses, which are increasing by approximately 30 % compared to the conventional two-level converter. The conduction losses are contributing with over 90 % to the total losses.

The switching losses of the three-level converter are approximately 60 % smaller for all points of operation.

This is a huge improvement but does not influence the total losses due to their relatively low significance at the chosen switching frequency of 1050 Hz. However, for increasing switching frequencies, the switching losses are getting more important. Another advantage of the threelevel converter is that the low harmonic content allows to decrease the switching frequency considerably compared to the two-level converter, which will further decrease the switching losses.

It is also interesting to see how the distribution of the conduction losses between the IGBT and their antiparallel diodes changes depending on the operation point and the line- or rotor-side converter.

It is also noticeable that the total losses are the smallest when the DFIG system is operating near the synchronous speed. The total losses are slightly increasing with an increasing slip.

V. C OST COMPARISON

A cost comparison ist not simple and would require further design consideration in order to get accurate results. However, it is possible to estimate the thendency by watching at the rating of the semiconductor devices and the size of the DClink capacitors.

5

TABLE VI

L OSS COMPARISON BETWEEN TWO AND THREE LEVEL CONVERTER TOPOLOGIES FOR DIFFERENT OPERATION POINTS .

Slip s

Shaft speed ω mech

0.3

0.7

ω s

0.2

0.8

ω s

Electrical phase quantities of the rotor-side converter

Voltage u r

[

ˆ

Current i r

[

ˆ

]

] 294.1

475.5

196.1

475.5

cos φ r cos φ s

-0.72

Electrical phase quantities of the line-side converter

Voltage u s

[

ˆ

]

Current i s

[

ˆ

]

563.4

374.1

563.4

349.3

-0.48

-0.72

-0.34

0.1

0.9

ω

97.5

475.5

-0.71

563.4

332.8

-0.18

s

0

ω s

1.1

475.5

N.A.

563.4

328.0

0.0

-0.1

1.1

ω

99.2

475.5

0.76

563.4

333.9

0.18

s

-0.2

1.2

ω

197.2

475.5

0.73

563.4

349.3

0.34

s

-0.3

1.3

ω

295.8

475.5

0.72

563.4

374.1

0.48

s

Losses in the rotor-side converter

Topology 2level 3level 2level 3level 2level 3level 2level 3level 2level 3level 2level 3level 2level 3level

Switching losses [W]

IGBT conduction [W]

Diode conduction [W]

Total [W]

305

1419

572

2295

102

1661

885

2648

305

1313

648

2266

102

1538

1002

2642

305

1205

725

2235

103

1413

1121

2637

320

1130

824

2274

98

1329

1275

2702

305

991

879

2175

151

1161

1360

2673

305

888

953

2146

150

1041

1475

2666

305

784

1028

2117

150

921

1589

2660

Losses in the line-side converter

Topology 2level 3level 2level 3level 2level 3level 2level 3level 2level 3level 2level 3level 2level 3level

Switching losses [W]

IGBT conduction [W]

Diode conduction [W]

Total losses [W]

Difference [%]

250

560

944

119

652

1351

4048

+18

4771

234

593

791

109

694

1138

1941 Total [W] 1753 2123 1619

Total losses in the DFIG back-to-back converter

Switching losses [W]

Difference [%]

555 221 539

Conduction losses [W]

Difference [%]

-60

3493

+30

4550

211

-61

3346

+31

4372

3885

+18

4583

226

646

670

1541

531

-61

3776

+18

102

756

965

1823

205

3245

+31

4255

4460

221

733

578

1532

541

-64

96

858

833

1788

194

3265

+32

4296

3806

+18

4490

226

855

511

1593

531

-54

3237

+32

4257

3768

+19

93

998

737

1828

244

4501

234

1009

467

1710

539

-55

3856

+19

94

1173

671

1939

244

3317

+31

4361

4605

249

1208

439

1897

554

3460

4014

-56

+31

+19

95

1397

629

2121

245

4536

4781

The rating of the semiconductor devices is comparable for the two different converter topologies. The three-level converter, however, has an additional clamping diode module for each

VSC. The costs for the gate drive and control system are also increasing somewhat for the three-level converter, as the number of IGBTs is twice the one in the two-level converter and the control of mainly the DC capacitor voltage is more complex as it is shown below.

level converter, it is not possible for the three-level converter.

Even the largest available capacitor with 10 mF does not limit the voltage ripple to below 40 %. It can be noticed that the

DC-link voltage has to be actively controlled by the line-side

VSC in order to keep it in a reasonable range. A comparison for the chosen configuration shows that the capacitor size is twice as large for the three-level compared to the twolevel converter topology. Both implemented capacitors have the same dimensions (75 mm diameter, 145 mm length), but the number of required components differs with a factor two.

The DC capacitor volume will also affect the costs for the two converter topologies. It has to be calculated in order to limit the voltage ripple to a comparable level. An acceptable voltage ripple is 5 %. The size of the capacitance is then determined by the capacitor current, which is shown in Figure 8 for the twoand three-level converters. It can be seen that the short-time average current in the two-level converter is approximately zero, unlike for the three-level converter, where it is varying considerably. This is due to the different duty ratios of the semiconductor devices. As expected, this fact has a strong influence on the voltage ripple, as shown in Figure 9. While the voltage ripple can easily be limited to below 5 % for the two-

In order to do an appropriate cost comparison, it would also be essential not only to consider the initial costs but also the costs due to increased or decreased system losses. However, this is out of the scope of this work.

VI. C ONCLUSIONS

A conventional two-level and a three-level diode-clamped converter have been introduced for the application in the backto-back converter of a DFIG wind turbine. A comprehensive loss evaluation showed that the system losses are lower for the two-level converter for any point of operation. This is valid

6

2−level converter

400

200

0

−200

−400

−600

0 0.002

0.004

0.006

0.008

0.01

Time [s]

0.012

3−level diode−clamped converter

0.014

0.016

0.018

0.02

400

200

0

−200

−400

−600

0 0.002

0.004

0.006

0.008

0.01

Time [s]

0.012

0.014

0.016

0.018

0.02

Fig. 8.

Capacitor current for the 2- and 3-level converter topologies.

2−level converter

1230

1220

1210

1200

1190

1180

1170

1160

0 0.002

0.004

0.006

0.008

0.01

Time [s]

0.012

3−level diode−clamped converter

0.014

0.016

0.018

0.02

750

700

650

600

550

500

450

0 0.01

0.02

0.03

Time [s]

0.04

0.05

0.06

0.07

Fig. 9.

Capacitor voltage for the 2- and 3-level converter topologies.

for the investigated switching frequency of 1050 Hz, where the conduction losses are dominating over the switching losses. It was also shown that the initial costs of the three-level converter are somewhat increased due to the larger DC-link capacitors required. The future will show if and in what applications the obvious advantages of multi-level converters can stand up to the simplicity and robustness of conventional two-level converters.

R EFERENCES

[1] S. M ¨uller, M. Deicke, R. W. de Doncker, Doubly Fed Induction Gener-

ator Systems for Wind Turbines, IEEE Industry Applications Magazine,

May/June 2002.

[2] Wind Power in Power Systems, Editor T. Ackermann, John Wiley & Sons,

Ltd. 2005.

[3] R. Pena, J. C. Clare, G. M. Asher, Doubly Fed Induction Generator using Back-to-back PWM Converters and its Application to Variable-

Speed Wind-Energy Generation, IEE Proc.-Electr. Power Appl., Vol. 143,

No. 3, May 1996.

[4] Semikron, http://www.semikron.com.

[5] Evox Riva, http://www.evox-rifa.com/europe/index.html

7