20070004 REV 5 (TLED - C-TC)

advertisement
TLED-C/TC
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY
DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
Installation and servicing of this equipment should be performed by qualified service personnel only.
Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
Do not mount near gas or electrical heaters.
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by
unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any
modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
•
•
•
•
•
INSTALLATION INSTRUCTIONS
The LED Canopy light is designed to be mounted to a recessed J-box on celling wall or can be pendant mounted using
optional pendant mount adapter. Please consult with your lighting designer to obtain the optimum installation location.
Note: The TLED-C is not designed to be wired using surface mounted conduit.
1: Remove 4 cover plate screws and disconnect LED
driver connectors.
2: Mount cover plate to junction box using the
provided slots.
Electrical wire opening or Pendant mount hole.
20070004 REV 5 09/15
1
800.533.3948 • www.barronltg.com
TLED-C/TC
INSTALLATION INSTRUCTIONS
3: Electrical connection should be made inside junction box. Cap all unused leads to prevent shorting.
This fixture auto adjusts for voltages between 120VAC - 277VAC.
BLK
LINE
LINE
LED
NEUTRAL DRIVER
GND
– OUT
+ DIM
– DIM
WHI
NEUTRAL
CONNECT TO 0-10V
DIMMING CONTROL
LED
LIGHT
ENGINE
+ OUT
– OUT
LED
NEUTRAL
DRIVER + DIM
GND
– DIM
LINE
GRN
WHI
BLK
CONNECT TO AC POWER
+ OUT
GRN
GND
SP
black - line
white - neutral
green - ground
CONNECT TO 0-10V
DIMMING CONTROL
SP
SURGE PROTECTION
4: Connect the LED driver harness(s) to the LED light engine.
WARNING!
Do not allow the TLED-C to
hang from the harness. This
may cause damage to the
circuit.
5: Mount bottom enclosure to the cover plate with 4 screws.
OPERATION
The LED Canopy requires no special handling. Power “ON” or power “Cycle” requirements. We do recommend routine
inspections to visually verify that the fixtures are “ON” and emitting light. Any unit that is not functioning should be
inspected and repaired or replaced.
TROUBLE SHOOTING
Canopy does not turn “ON”
1. Check incoming voltage to LED driver. Must be at least a minimum of 120VAC and no greater than 277VAC.
2. Are all the LEDs on the light engine “OFF”? If so, LED driver may be defective. Using a voltmeter, check to see if
voltage is present at the output of power supply. If low or no voltage, then replace power supply.
3. If any individual LEDs are “OFF” the LED light engine is defective. Please have the serial number off the light engine
available when you contact technical support.
20070004 REV 5 09/15
2
800.533.3948 • www.barronltg.com
TLED-RC
INSTALLATION INSTRUCTIONS
SAVE THESE INSTRUCTIONS!
READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY
DISCONNECT AC POWER SUPPLY BEFORE SERVICING.
Installation and servicing of this equipment should be performed by qualified service personnel only.
Ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.
Do not mount near gas or electrical heaters.
Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by
unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. Any
modification or use of non-original components will void the warranty and product liability.
• Do not use this equipment for other than intended use.
•
•
•
•
•
INSTALLATION INSTRUCTIONS
The Recessed Canopy is designed to be recessed mounted in walls, ceilings, or overhead canopies. Please consult
your lighting designer to obtain the optimum installation location.
1. Remove wireway cover by loosing 4 screws. Feed
supply wires through knockout and secure with fitting or
bushing per local code. (Fig.1)
2. Fixture is supplied with a safety cable. Attach the
safety cable in a secure place within the cut out opening
to support the fixture for ease of wiring. Safety cable can
be left secured after installation is complete. (Fig. 2)
Fig. 1
Fig. 2
Supply Wires
Wire Way
Cover
WARNING!
Do not allow the unit to
hang from the harness.
This may cause damage
to the circult.
Safety Cable
Wire Way
Cover Screws
20070009 REV 3 05/15
1
800.533.3948 • www.barronltg.com
TLED-RC
INSTALLATION INSTRUCTIONS
3. Electrical connections should be made inside wireway cover. Cap all unused leads to prevent shorting.
This fixture auto adjust for voltage between 120VAC - 277VAC.
BLK
LINE
LINE
LED
NEUTRAL DRIVER
GND
– OUT
+ DIM
– DIM
WHI
NEUTRAL
LINE
GRN
GND
CONNECT TO 0-10V
DIMMING CONTROL
LED
LIGHT
ENGINE
+ OUT
GRN
WHI
BLK
CONNECT TO AC POWER
+ OUT
SP
NEUTRAL
GND
– OUT
LED
DRIVER + DIM
– DIM
black - line
white - neutral
green - ground
CONNECT TO 0-10V
DIMMING CONTROL
SP
SURGE PROTECTION
4. Secure wireway cover retightening 4 screws. Make sure no wires are being pinched when securing
cover wireway.
Wire Way
Cover Screws
20070009 REV 3 05/15
2
800.533.3948 • www.barronltg.com
TLED-RC
INSTALLATION INSTRUCTIONS
5. Position fixture trim plate in opening. The trim plate can be securely fastened using the (4) Corner hole positions to
the finished surface material using appropritate anchors/hardware. (NOT SUPPLIED) (Fig. 4)
Fig. 4
OPERATION
The Canopy requires no special handling. Power “ON” or power “Cycle” requirements. We do recommend routine
inspections to visually verify that the fixtures are “ON” and emitting light. Any unit that is not functioning should be
inspected and repaired or replaced.
TROUBLE SHOOTING
Canopy does not turn “ON”
1. Check incoming voltage to LED driver. Must be at least a minimum of 120VAC and no greater than 277VAC.
2. Are all the LEDs on the light engine “OFF”? If so, LED driver may be defective. Using a voltmeter, check to see if
voltage is present at the output of power supply. If low or no voltage, then replace power supply.
3. If any individual LEDs are “OFF” the LED light engine is defective. Please have the serial number off the light
engine available when you contact technical support.
20070009 REV 3 05/15
3
800.533.3948 • www.barronltg.com
Download