Compatible with most electronic AC ballasts Maintenance

advertisement
● Compatible
with most
electronic AC ballasts
● Maintenance-free, long-life,
high temperature Ni-Cad battery
● Durable, heavy duty steel housing
● 5-year warranty
FLUORESCENT
EMERGENCY BALLAST
1300 Lumens
JWEB-1300
Description:
The VEM1300DV fluorescent emergency ballast works in
conjunction with the AC ballast to allow the same fluorescent fixture
to be used for both normal and emergency operations. When AC
power fails, the VEM1300DV switches to emergency mode and
keeps the lamp(s) illuminated at a reduced lumen output for a
minimum of 90 minutes. The VEM1300DV is suitable for use in new
fixtures or retrofit applications. Includes LED charging indicator light,
sigle-pole test switch, and installation hardware.
Dual voltage (120/277V)
Compatible with most electronic AC ballasts
Maintenance-free, long-life, high temperature Ni-Cad battery
For use with switched or unswitched fixtures
Does not affect normal operation
May be installed in the wireway or on top of fixture
Emergency ballast must be fed from the same branch circuit as
the AC ballast
Durable, heavy duty steel housing in painted white finish
Low-profile design fits most fluorescent fixtures
Warranty:
●
●
End-of-lamp-life compatible
Input Voltage
120/277 VAC, 60Hz
● 1-lamp 2’-8’ single, T8, T10, T12
U-bent or circline, Rapid or Instant Start
● 2-lamp 2’-4’ single, T8, T10, T12
U-bent or circline, Rapid or Instant Start
Emergency Operation
90 mins
Housing:
●
●
Operates 1-lamp 2’-8’ or 2-lamp 2’-4’
Single, Bi-pin, T8, T10, T12, U-bent or
circline, Rapid or Instant Start
Lamps Operated
Installation:
●
●
●
●
VEM1300DV
Technical Specifications
Electrical:
●
●
●
Model:
Initial Illumination
1-lamp: 1300 lumens
2-lamp: 1300 lumens (650 lumens/lamp)
Operating Temperature
5 years
Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA,
Local and State Codes
Case Dimensions:
0°C to 50°C
Battery
24 hr recharge, 7-10 yr life expectancy
Nickel-Cadmium
Approval
W: 2.38”
UL and cUL Listed
L: 13.38”
H: 1.50”
M: 12.88”
Specification data is based on tests performed in a controlled environment and represents relative performance. Actual performance can
vary depending on operating conditions. Application and performance data subject to change without notice. All specifications are nominal
unless noted otherwise.
ESPEN Technology, Inc.
12257 Florence Ave ● Santa Fe Springs, CA 90670
Phone: (562) 529-2938 ● Fax: (562) 529-2978 ● Toll Free: (886) 933-7736
Email: info@espentech.com ● www.espentech.com
FLUORESCENT
EMERGENCY BALLAST
700 Lumens
JWEB-700T5-UN
Description:
The VEM700MV-SL fluorescent emergency ballast works in
conjunction with the AC ballast to allow the same fluorescent fixture
to be used for both normal and emergency operations. When AC
power fails, the VEM700MV-SL switches to emergency mode and
keeps one lamp illuminated at a reduced lumen output for a
minimum of 90 minutes. The VEM700MV-SL is suitable for use in
new fixtures or retrofit applications. Includes LED charging indicator
light, sigle-pole test switch, and installation hardware.
Model:
Operates 14-28W (2’-4’) T5, 24-54W
(2’-4’) T5HO, 32W (4’) or 40W (5’) T8,
44W (4’) T8HO, 36-55W 4-pin long
compact fluorescent
End-of-lamp-life compatible
Technical Specifications
Input Voltage
100-277 VAC, 50/60Hz
Electrical:
●
●
●
Universal input voltage (100-277V)
Compatible with most electronic AC ballasts
Maintenance-free, long-life, high temperature Ni-Cad battery
Lamps Operated
●
●
●
●
●
Installation:
●
●
●
●
For use with switched or unswitched fixtures
Does not affect normal operation
May be installed in the wireway or on top of fixture
Emergency ballast must be fed from the same branch circuit as
the AC ballast
90 mins
Initial Illumination
700 lumens
Zinc-plated steel housing
Low-profile design fits most fluorescent fixtures
Operating Temperature
0°C to 50°C
Battery
Warranty:
●
●
14-28W (2’-4’) T5
24-54W (2’-4’) T5HO
32W (4’) or 40W (5’) T8
44W (4’) T8HO
36-55W 4-pin long compact fluorescent
Emergency Operation
Housing:
●
●
VEM700MV-SL
5 years
Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA,
Local and State Codes
24 hr recharge, 7-10 yr life expectancy
Nickel-Cadmium
Approval
UL and cUL Listed
Case Dimensions:
W: 1.18”
L: 18.50”
H: 1.18”
M: 18.00”
Specification data is based on tests performed in a controlled environment and represents relative performance. Actual performance can
vary depending on operating conditions. Application and performance data subject to change without notice. All specifications are nominal
unless noted otherwise.
ESPEN Technology, Inc.
12257 Florence Ave ● Santa Fe Springs, CA 90670
Phone: (562) 529-2938 ● Fax: (562) 529-2978 ● Toll Free: (886) 933-7736
Email: info@espentech.com ● www.espentech.com
FLUORESCENT
EMERGENCY BALLAST
700 Lumens
JWEB-700-2
Description:
The VEM700DV fluorescent emergency ballast works in conjunction
with the AC ballast to allow the same fluorescent fixture to be used
for both normal and emergency operations. When AC power fails,
the VEM700DV switches to emergency mode and keeps the
lamp(s) illuminated at a reduced lumen output for a minimum of 90
minutes. The VEM700DV is suitable for use in new fixtures or
retrofit applications. Includes LED charging indicator light, sigle-pole
test switch, and installation hardware.
Dual voltage (120/277V)
Compatible with most electronic AC ballasts
Maintenance-free, long-life, high temperature Ni-Cad battery
For use with switched or unswitched fixtures
Does not affect normal operation
May be installed in the wireway or on top of fixture
Emergency ballast must be fed from the same branch circuit as
the AC ballast
Durable, heavy duty steel housing in painted white finish
Low-profile design fits most fluorescent fixtures
Warranty:
●
●
End-of-lamp-life compatible
Input Voltage
120/277 VAC, 60Hz
● 1-lamp 2’-8’ single, T8, T10, T12
U-bent or circline, Rapid or Instant Start
● 2-lamp 2’-4’ single, T8, T10, T12
U-bent or circline, Rapid or Instant Start
Emergency Operation
90 mins
Housing:
●
●
Operates 1-lamp 2’-8’ or 2-lamp 2’-4’
Single, Bi-pin, T8, T10, T12, U-bent or
circline, Rapid or Instant Start
Lamps Operated
Installation:
●
●
●
●
VEM700DV
Technical Specifications
Electrical:
●
●
●
Model:
Initial Illumination
1-lamp: 700 lumens
2-lamp: 700 lumens (350 lumens/lamp)
Operating Temperature
5 years
Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA,
Local and State Codes
Case Dimensions:
0°C to 50°C
Battery
24 hr recharge, 7-10 yr life expectancy
Nickel-Cadmium
Approval
W: 2.38”
UL and cUL Listed
L: 9.69”
H: 1.50”
M: 8.81”
Specification data is based on tests performed in a controlled environment and represents relative performance. Actual performance can
vary depending on operating conditions. Application and performance data subject to change without notice. All specifications are nominal
unless noted otherwise.
ESPEN Technology, Inc.
12257 Florence Ave ● Santa Fe Springs, CA 90670
Phone: (562) 529-2938 ● Fax: (562) 529-2978 ● Toll Free: (886) 933-7736
Email: info@espentech.com ● www.espentech.com
FLUORESCENT
EMERGENCY BALLAST
500 Lumens
JWEB-500
Description:
The VEM500DV fluorescent emergency ballast works in conjunction
with the AC ballast to allow the same fluorescent fixture to be used
for both normal and emergency operations. When AC power fails,
the VEM500DV switches to emergency mode and keeps one lamp
illuminated at a reduced lumen output for a minimum of 90 minutes.
The VEM500DV is suitable for use in new fixtures or retrofit
applications. Includes LED charging indicator light, sigle-pole test
switch, and installation hardware.
Dual voltage (120/277V)
Compatible with most electronic AC ballasts
Maintenance-free, long-life, high temperature Ni-Cad battery
For use with switched or unswitched fixtures
Does not affect normal operation
May be installed in the wireway or on top of fixture
Emergency ballast must be fed from the same branch circuit as
the AC ballast
Housing:
●
●
End-of-lamp-life compatible
Input Voltage
120/277 VAC, 60Hz
2’-4’ single, Bi-pin, T8, T10, T12,
U-bent or circline, Rapid or Instant Start
Emergency Operation
90 mins
Initial Illumination
500 lumens
Durable, heavy duty steel housing in painted white finish
Low-profile design fits most fluorescent fixtures
Warranty:
●
●
Operates 2’-4’ single, Bi-pin, T8, T10,
T12, U-bent or circline, Rapid or Instant
Start
Lamps Operated
Installation:
●
●
●
●
VEM500DV
Technical Specifications
Electrical:
●
●
●
Model:
Operating Temperature
0°C to 50°C
Battery
5 years
Meets UL924, NFPA 101 Life Safety Code, NEC, OSHA,
Local and State Codes
24 hr recharge, 7-10 yr life expectancy
Nickel-Cadmium
Approval
UL and cUL Listed
Case Dimensions:
W: 2.38”
L: 9.50”
H: 1.50”
M: 8.94”
Specification data is based on tests performed in a controlled environment and represents relative performance. Actual performance can
vary depending on operating conditions. Application and performance data subject to change without notice. All specifications are nominal
unless noted otherwise.
ESPEN Technology, Inc.
12257 Florence Ave ● Santa Fe Springs, CA 90670
Phone: (562) 529-2938 ● Fax: (562) 529-2978 ● Toll Free: (886) 933-7736
Email: info@espentech.com ● www.espentech.com
Download