Bussmann®
Automotive Blade-Type Fuses
ATM
32 Volts DC, 2 to 30 Amps
15A
20A
25A
30A
2A
7.5A
10A
Time-Current Characteristic Curves–Average Melt
.430∑
10.92mm
3A
4A
5A
Dimensional Data
100
AMPERE
RATING
.15∑
3.81mm
.347" (±0.016)
8.81mm (±0.41)
10
Catalog Symbol: ATM
Fast-Acting
Ampere Ratings: 2 to 30 Amperes
Voltage Rating: 32 Volts DC (or less)
Interrupting Rating: 1,000 Amperes
Electrical Ratings (Catalog Symbol, Amp Rating, and Color)
ATM-2
Gray
ATM-7⁄Ω™
Brown
ATM-25
Clear
ATM-3
Violet
ATM-10
Red
ATM-30
Green
ATM-4
Pink
ATM-15
Blue
—
—
ATM-5
Tan
ATM-20
Yellow
—
—
TIME IN SECONDS
.295" (±0.012)
7.50mm (±0.30)
1
.1
Shelf Carton Quantity and Weight
100
20 (5-in)
0.40
Volume
(Cu. Ins.)
2.88 ≈ 3.5 ≈ 1.75
17.6
.01
CURRENT IN AMPERES
200
ATM
Dimensions
(Inches)
100
Wgt.
(Lbs.)
10
No. of
Boxes
1
Fuse
Qty.
.4
Fuse
Type
Recommended Bussmann Fuseholders
Blade-Type
ATM
Part
Description
HHM
Fuseholder w/Cover
HHM-B
Body Only
HHM-C
Cover Only
HHL
Fuseholder w/Cover
HHL-B
Body Only
Fuse Size
3-30 Amps
—
2-20 Amps
Wire Size
#12 Red Lead Wire;
4 3/4∑ Length Stripped to 1/4”
Maximum Continuous
Current Rating
24 Amps*
—
#16 Black Lead Wire;
4 3/4∑ Length Stripped to 1/4”
16 Amps*
* Or 80% of fuse rating, whichever is less.
The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin
is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
9-19-01
SB01368
Form No. ATM