MSAT-XEE 8.2÷30.2 new product Condensing unit Cooling only Air cooled Outdoor installation Capacity from 26 to 80 kW The MSAT air-cooled condensing units have been designed for outdoor installation and for best energy efficiency in relation to reduced size. They may be combined with terminal units or connected to exchanger coils of air-handling units. The main features are: HIGH ENERGY EFFICIENCY, especially during operation at partial loads, thanks to the use of two compressors of different capacity operating on a single cooling circuit; SELF-ADAPTING - The evolved electronics implemented adapt the operating parameters to the load conditions of the system it is installed in, optimising consumption, noise and the working life of the components; COMPACT SIZE - The units are designed to reduce overall dimensions to a minimum, a decisive factor to adapt to the features of any building. functions and features AIR Cooling only Air cooled R-410A Outdoor installation R-410A Hermetic Scroll dimensions and clearances C AUXILIARY B1 A2 B B2 A A1 CAUTION!For trouble-free operation of the unit it is essential to maintain the safety distances indicated by the green areas. 244 Size – MSAT-XEE A - Length B - Width C - Height A1 A2 B1 B2 Operating weight mm mm mm mm mm mm mm kg 8.2 1739 721 1287 700 700 700 700 298 10.2 1739 721 1287 700 700 700 700 303 12.2 1739 721 1287 700 700 700 700 323 16.2 1967 1143 1599 700 700 700 700 456 18.2 1967 1143 1599 700 700 700 700 469 22.2 1967 1143 1599 700 700 700 700 490 26.2 2367 1141 1593 700 700 700 700 547 30.2 2367 1141 1593 700 700 700 700 561 The above mentioned data are referred to standard units for the constructive configurations indicated. For all the other configurations, refer to the relative Technical Bulletin. technical data Size – MSAT-XEE Cooling capacity Compressor power input Total power input EER Refrigeration circuits No. of compressors Type of compressors Standard airflow Standard power supply Sound pressure level (1) (1) (1) (1) (2) kW kW kW Nr Nr l/s V dB(A) 8.2 25,7 8,79 6,30 2,78 1 2 SCROLL 2553 400/3/50+N 60 Notes (1) Saturated suction temperature (SST) = 5°C; Outdoor air temperature 35°C (2) The sound levels refer to the unit at full load, in the rated test conditions. 10.2 31,3 9,95 10,4 3,01 1 2 SCROLL 2545 400/3/50+N 60 12.2 36,0 12,4 12,9 2,80 1 2 SCROLL 2514 400/3/50+N 60 16.2 43,4 14,1 15,6 2,78 1 2 SCROLL 4965 400/3/50+N 64 18.2 51,6 16,2 17,7 2,91 1 2 SCROLL 4902 400/3/50+N 64 22.2 59,1 20,3 21,8 2,71 1 2 SCROLL 4778 400/3/50+N 65 26.2 72,3 22,6 24,2 2,99 1 2 SCROLL 7196 400/3/50+N 65 30.2 80,1 26,6 28,4 2,82 1 2 SCROLL 6971 400/3/50+N 65 The sound pressure level refers to a distance of 1m from the external surface of the units operating in an open field. accessories KCX AMRX ■• PGCEX PM ■• ■• Connection set Rubber antivibration mounts Coil protection grilles outdoor air side Phase monitor PMX CBRX MEN30 MEN15 ■• ■• Phase monitor Unit with remote keypad. Minimum external air temperature down to -30°C Minimum external air temperature down to -15°C Key to symbols: Accessories separately supplied REF-DG14B001GB-00 AUXILIARY ■• Data contained in this document are not binding and may be changed by the Manufacturer without notice. www.clivet.com 245