LIGHTNING AND SURGE PROTECTION FOR INDUSTRIAL, COMMERCIAL AND DOMESTIC ELECTRICAL INSTALLATIONS WWW.SURGEDEVICES.CO.UK Servers Surge Protection Devices and its Partner Companies have been solving problems in Lightning and Surge Protection for over 50 years. ISO 9001 European designed and manufactured, state of the art products which exceed the requirements of the latest Standards and our competitors’ specifications. Because we specialise in Lightning and Surge protection we can offer you the very best, most cost-effective solution of any company in this field. We carry out many seminars with consultants and specialist training organisations as well as attending exhibitions and conferences both in the UK and overseas where our specialist knowledge is renowned. Schools Wi nd SPD Ltd stands for innovation, quality and excellent customer service. FREE technical help. Assistance with product selection and design. We can carry out site surveys. We can assist with compliance to the latest requirement of the Wiring Regulations. BS7671 and BSEN62305 Lightning Standards. domestic 2 Surge Protection Specialists Tu rb ine s la r So An introduction to Lightning Surge Protection Lightning/Surge protection for electrical and electronic systems to the new British and European Standard BS EN 62305-4. Surge Protection Devices Ltd offer the complete solution to protect vital systems from damage. Recently introduced standards put equal importance on protecting the electrical installation and electrical equipment as to the building itself. Modern micro electronic components are very sensitive to overvoltages and because many systems are networked they rely on each other for the system to operate. If one part of the system gets damaged due to lightning or surges, the whole system will not operate. The consequential losses suffered during such events i.e. downtime and lost production, can be very high. We offer a wealth of experience in helping to decide which product best suits your needs. Our catalogue contains our most popular products however we have many more products and components to suit a range of applications. Hospitals MOD New Standard BSEN62305-4 1st Sept 2008 & 17th Edition Wiring Regs Amendments 1st Jan 2012. This new standard replaced BS6651 on the above date, it is now mandatory to fit a lightning current arrester on main incoming panels which are situated in buildings with external lightning conductors or fed by an overhead line. This type of arrester is designated as a Type 1, we recommend a combined T1+T2+T3 arrester as this gives additional surge protection for no added cost. The minimum discharge capability for a T1 arrester has to be 50Ka 10/350μs. Panels or sub-distboards feeding external circuits such as car park lighting, CCTV etc should also have a combined T1+T2+T3 arrester fitted as standard. An example of a T1+T2+T3 combined arrester is 10651 LED Level 1, 100Ka 10/350μs. For panels and sub boards in buildings without external lightning conductors and fed by underground cables a T2 surge arrester is sufficient. Sub-distribution boards or local control panels more than 10 metres from the main incomer and not feeding external circuits then a Type 2 surge arrester can be used. An example of a T2 surge arrester is Part no SY2-C40X. Final sub-circuits and sensitive electronic equipment, e.g. fire/burglar panels, PLC’s which are fitted more than 10 metres from the last surge arrester should have a T3 surge arrester fitted at the panel or equipment to be protected. An example of a T3 surge arrester is SY2-D/LED. For further information on surge protection recommendations please call us on 01484 851747. 3 Main Incoming Position Sub Dist. Board Position Socket Outlet or Final Sub PROTECTION AGAINST PROTECTION AGAINST PROTECTION AGAINST DIRECT LIGHTNING INDIRECT LIGHTNING SWITCHING OVERVOLTAGES CURRENTS EFFECTS (SURGE ARRESTER) (LIGHTNING CURRENT (SURGE ARRESTER) 8/20μs ARRESTER) 8/20μs Type 1 Type 2 Type 3 10/350μs General distribution of lightning current when a building is hit by lightning. LV power system protection thanks to cascaded 3-stage protection. SPD Type 1 4 SPD Type 2 Surge Protection Specialists SPD Type 3 Type 1+2+3 Combined Lightning & Surge Arresters, DIN Rail Mountable. Fully Compliant to EN/IEC61643-11, BS/IS/EN62305, BS7671 LPL Level 1 100kA 10/350μs 4 Pole Data Sheet LED Indication Version Part No. 10651 LED TP+N Maximum continuous operating voltage Uc 275 V AC Lightning impulse current (10/350) - charge - specific energy Iimp Q W/R 25kA 12,5As 156kJ/ Total lightning current (10/350) L1 + L2 + L3 + N - PE Itotal 100kA Max. discharge current (8/20) per mode Imax 120kA Nominal discharge current (8/20) per mode In 50kA Voltage protection level at Iimp Up <1.2kV Response time tA <25ns Temporary overvoltage (TOV) UT 335V/5 sec. Rec. Back-up fuse / MCCB 63A/100A Max. Back-up fuse (“V” connection) 63AgL/gG Short circuit withstand capability at max back-up fuse Ip Weight m 80kArms 1125g Lifetime min 100 000 h Let through voltage (I) 3ka 8/20μs, short circuit current to BS6651+1999 AppC 600V Part No. 1065 I LED Part No. 10651LED LPL Level 3/4 50kA 10/350μs 2 Pole Data Sheet Part No. 10650/LED SP+N Part No. 10650LED Maximum continuous operating voltage Uc 275 V AC Lightning impulse current (10/350) - charge - specific energy Iimp Q W/R 25kA 12,5As 156kJ/ Total lightning current (10/350) L1 + N-PE 50kA Itotal 50kA Max. discharge current (8/20) per mode Imax 120kA Nominal discharge current (8/20) per mode In 50kA Voltage protection level at Iimp Up < 1.2kV Response time tA < 25ns Temporary overvoltage (TOV) UT 335 V/5 sec. Rec. Back-up fuse / MCCB 63A/100A Max. Back-up fuse (“V” connection) 63AgL/gG Short circuit withstand capability at max back-up fuse Ip 80kArms Weight m 565g Let through voltage (I) 3ka 8/20μs, short circuit current to BS6651+1999 AppC 600V Part No. 10650 LED For 2 pole level 1 100kA 10/350μs specify HS50-50 1+1LED 5 Type 1+2+3 Combined Lightning and Surge Arresters - DIN Rail Mountable. Fully Compliant to EN/IEC61643-11, BS/EN/IEC62305, BS7671 LPL Level 1 100kA 10/350μs 4 Pole Data Sheet Window Indication Version Part No. 383811 TP+N Part No. 383811 64 Maximum continuous operating voltage Uc 275 V AC Lightning impulse current (10/350) - charge - specific energy Iimp Q W/R 25kA 12,5As 156kJ/ Total lightning current (10/350) L1 + L2 + L3 + N - PE Itotal 100kA Max. discharge current (8/20) per mode Imax 150kA Nominal discharge current (8/20) per mode In 70kA Voltage protection level at Iimp Up <1.5kV Response time tA <25ns Temporary overvoltage (TOV) UT 335V/5 sec. Rec. Back-up fuse / MCCB 63A/100A Max. Back-up fuse (“V” connection) 63AgL/gG Short circuit withstand capability at max back-up fuse Ip 80kArms Weight m 1125g Lifetime min 100 000 h Let through voltage (I) 3ka 8/20μs, short circuit current to BS6651+1999 AppC 600V 383811 LPL Level 3/4 50kA 10/350μs SP+N Part No. 383812 2 Pole Data Sheet Part No. 383812 Maximum continuous operating voltage Uc 275 V AC Lightning impulse current (10/350) - charge - specific energy Iimp Q W/R 25kA 12,5As 156kJ/ Total lightning current (10/350) L1 + L2 + L3 + N - PE Itotal 50kA Max. discharge current (8/20) per mode Imax 150kA Nominal discharge current (8/20) per mode In 70kA Voltage protection level at Iimp Up <1.5kV Response time tA <25ns Temporary overvoltage (TOV) UT 335V/5 sec. Rec. Back-up fuse / MCCB 63A/100A Max. Back-up fuse (“V” connection) 63AgL/gG Short circuit withstand capability at max back-up fuse Ip 80kArms Weight m 565g Lifetime min 100 000 h Let through voltage (I) 3ka 8/20μs, short circuit current to BS6651+1999 AppC 600V 383812 For 2 pole level 1 100kA 10/350μs specify HS50-50 1+1LED 6 Surge Protection Specialists Lightning and Surge Protection for Industrial, Commercial and Domestic Electric Installations Type 1 + 2 + 3 Combined arresters in enclosures 383811 ENC TP+N • Type 1 + 2 + 3 combined direct lightning and surge arrester TP+N • Complete in high quality IP65 Polycarbonate enclosure • Meets level 1, 2, 3 + 4 100KA 10/350μs • Conforms to BSEN62305 EN61643-11, BS7671 Amendment Wiring Regs. • Use where building have external lightning protection or fed by overhead lines Dimensions (CM) : H20 x W26 x D11 383812 ENC SP+N • Visual and remote indication as standard • Low through voltage • Available with 63AMP backup MCB (add ‘M’ to part number - e.g. 383811 ENC M) • Each pole individually replaceable • SP+N version 50KA 10/350μs. Level 3-4 if 100KA needed then please ask for HS 50-50 1+1 ENC 100KA 10/350μs version • Use 63/100 AMP backup fuse or MCB • Cable size to be 25mm² min. Dimensions (CM) : H20 x W20 x D11 7 Type 1 + 2 + 3 Combined Lightning/Surge Arresters for DIN Rail Mounting Part No. 10020 Part No. 10020/4 8 Surge Protection Specialists Maximum continuous operating voltage Uc 275 V AC Lightning impulse current (10/350) - charge - specific energy 1mp Q W/R 25kA 12,5As 39kJ/ Max. discharge current Imax 100kA Nominal discharge current (8/20) In 20kA Temporary overvoltage (TOV) UT 335V/5 sec. Voltage protection level at Iimp Up <1.2kV Response time tA <25ns Rec. Back-up fuse / MCCB 63 AMPS Lifetime min. 100 000h Short circuit withstand capability at max back-up fuse Ip 60kA rms Weight m 140g Let through voltage (I) 3ka 8/20μs, short circuit current to BS6651+1999 AppC App C = 600V Part No. 1 Pole 10020 Part No. 2 Pole 10020/2 Part No. 4 Pole 10020/4 Type 1 + 2 + 3 Combined Lightning/Surge Arresters in Complete Enclosures Part No. 10020/4 ENC TP+N • Type 1 + 2 + 3 Level 3/4 50KA 10/350μs • Very low let-through voltage (less than 600v) • Fast response time less than <25ns • For LPL Zones 0-3 • IP65 Polycarbonate enclosure H20cm W20cm D11cm • With or without backup 63AMP MCB • Follow currents completely eliminated Part No. 10020/4 ENCM TP+N + MCB • Visual and remote monitoring as standard • Enhanced protection to BSEN 62305 • 1st Amendment, 17th Edition Wiring Regs. Compliant 9 Type 1 + Type 2 +Type 3 Combined Lightning/Surge Arrester for DIN Rail Mounting 4 Pole Lightning/Surge Arrester TP+N Max. continuous operating voltage Uc 275 V AC Lightning impulse current - charge - specific energy Iimp Q W/R 12,5 kA 6,25 As 39 KJ/Ω Total lightning current (10/350) L1 + L2 + L3 + N → PE Itotal 50 kA Nominal discharge current (80/20) In 20 kA Voltage protection level Up < 1,2 kV Temporary overvoltage (TOV) UT 335 V / 5 sec Response time tA < 25ns Max. backup fuse Short-circuit withstand capability at max. back-up fuse 160 AgL/gG Ip Lifetime Part No. 16057 • • • • • • • • • Arrester Type 1 + Type 2 + Type 3 4-pole arrester pluggable 3-phase power supply network TN-C-S LPZ 0-1 LPL III, IV Itotal 50kA 10/350μs Very low let-through voltage Visual indication of status Remote signal contacts Recomended back-up fuse/MCB Min 63 AMPS • Cable size 16mm² to 25mm² 10 Surge Protection Specialists Weight 60 kArms min. 100 000 h m 560g Part no 16057 Part no spare module 16058 Type 2/3 DIN Rail Mountable Surge Arresters Protect sensitive electronic equipment with high quality surge arresters. Today’s highly sensitive electronics require a higher level of protection; you can achieve this by using the following Lightning/Surge Arresters from Surge Protection Devices Ltd. They are quick and easy to install and are high-tech products at competitive prices compared with other brands. Type 2/3 Enhanced Pluggable Surge Arresters SPD According to IEC61643-1 EN61643-11 Type 2/3 Maximum continuous operating voltage UcV (350V DC) 275 VAC Voltage protection level In Up Voltage protection level at 5kA Up Voltage protection level at 3kA Up ≤ 1.3kV < 0.9kV < 0.6kV Nominal discharge current In (8/20μs)kA 20kA Nominal discharge current Imax (8/20μs)kA 40kA Withstand Short Circuit 50kA RMS Response time in ns <25ns Dimensions W 72mm H 90mm D 66mm Din-rail mountable Enclosure material Yellow/Grey UL94 V-O Degree of protection IP20 Recommended backup MCB/fuse Terminal capacity Visual indication of status Part No. SY1-C 40X Part No. SY2-C 40X SP+N TP+N Type 2/3 Enhanced Surge Arrester 2 pole (SP+N) Part No. SY2-D Pluggable version Part No. SY2-D LED LED version SP+N SP+N 32A to 63A Phase line Neutral line - 2.5~35mm² Earth Line - 4.0~35mm² Signal Line - 1.0mm² Remote Alarm Contact Green OK Red Replace Module Contact closes if any part of the device fails SPD According to IEC61643-1 EN61643-11 Type 2/3 Maximum continuous operating voltage UCV 275 V Voltage protection level Up 3kA (8/20μs)kA < 0.6kV Nominal discharge current In (8/20μs)kA 5kA Maximum discharge current Imax (8/20μs)kA 10kA Response time < 25ns Dimensions W 18mm H 90mm D 66mm Enclosure material Grey UL94 V-O Degree of protection IP20 Recommended backup MCB/fuse 32A or less Terminal capacity 1.5~4mm² Visual indication of status Black OK Red Replace Module DIN rail mountable Yes 11 Type 2/3 Enhanced Pluggable Surge Arresters in Enclosures SY2-C40X ENC TP+N • Type 2/3 Enhanced TP+N Pluggable Surge Arrester • Complete in high quality IP65 Polycarbonate enclosure • High surge capacity 40,000 AMPS per pole • Conforms to BSEN62305, EN61643-11 and BS7671 1st Amendment Wiring Regs. • Use where there is no external lightning protection and no overhead lines • Also use on sub-dist boards to protect sensitive electronic equipment Dimensions (CM) : H20 x W12 x D11 SY1-C40X ENC SP+N • Connection in parallel means no current limitations • Visual and remote indication as standard • Low let through voltage • Available with 63AMP backup MCB (add ‘M’ to part number - e.g. SY2-C40X ENCM) • Each pole individually replaceable • Use 32A to 63A backup MCB • Cable size 6mm² - 16mm² Dimensions (CM) : H20 x W12 x D11 12 Surge Protection Specialists Surge Arrester Type 2/3 Compact Type LED Indication P-3k is a three-phase surge arrester type 2/3 according to EN61643-11 and IEC 61643-1 suitable for use in TNS, TNC and TT systems. These are parallel devices intended for protection of electronic appliances against impulse surge. All varistors are fitted with thermal fuses to prevent short and also permanent overloading. These units are to be connected as near to the protected appliance as possible, e.g. local control panel, dist board. The right function of P-3k230 devices is indicated by target disconnection of mechanical thermal fuses which react to varistors overheating above c. 120˚C. Nominal voltage UN 230 V AC Max. continuous operating voltage Uc 275 V AC Nominal discharge current In(8/20) In 3 kA (L/N, L/PE) 5 kA (N/PE) Combined impulse Uoc 6 kV (L/N, L/PE) 10 kV (N/PE) Voltage protection level at Uoc Up <1,2 V (L/N) <1,2 kV (L/PE) <1,2 kV (N/PE) c. 3VA / 0,1 VA Power loss at winding temp. 20˚C Response time tA <25ns (L/N) <100ns (L/PE, N/PE) Recommended backup fuse 16A Lifetime min. 100.000 h Weight Part no m 140/205g 30 105 Part No. 30 105 Recommended connection of 30105 Basic circuit diagram of 30105 13 Type 3 Surge Arrester For electrical installation systems Surge protection device for electrical installation systems Type 3 to EN61643-11 Nominal voltage Un 230 V AC Max. continuous operating voltage Uc 275 V AC Nominal discharge current In (8/20) In 3 kA (L/N, L/PE) 5 kA (N/PE) Combined impulse Uoc 6 kV (L/N) 10 kV (N/PE) Voltage protection level at Uoc Up 1 kV (L/N) <1 kV (L/PE) <1,2 kV (N/PE) 0,5 W Power loss at winding temp. 20˚C Response time 32006 is surge arrester type 3 according to EN 61643-11 dsigned for installation into electrical installation systems, e.g.: cable ducts, flushmounted sockets or fire alarm panels as an additional protection measure. Recommended backup fuse 32006 contains an acoustic fault indicator (buzzer) and is earth leakage free. Weight Temporary overvoltage (TOV) <25 ns (L/N) <100 ns (L/PE, N/PE) 16A UT 335V/5 s (L/N) 1200V + U0/200 ms (L/PE) Lifetime Min. 100.000 h Failure indication 32006 inbuilt piezosiren Part No. Basic circuit diagram of 32006 Recommended connection of 32006 14 TA Surge Protection Specialists m 20/30g 32006 Surge Arresters - Varistor and EMC/EMI Filter Type 3 PI-k and PI-k16 are type 3 single phase surge arresters with a high frequency filter according to EN61643-11 and IEC 61643-1. They are produced for nominal current within the range of 8, 16, 25, 32 for mounting on DIN rail 35mm. For protection of single-phase electronic appliances in L.V. supply systems against impulse surge and high-frequency disturbance. Nominal voltage UN 230 V AC Max. continuous operating voltage Uc 275 V AC Nominal current IN 8A Nominal discharge current In(8/20) In 3 kA (L/N, L/PE) 5 kA (N/PE) Combined impulse Uoc 6 kV (L/N, L/PE) 10 kV (N/PE) Voltage protection level at Uoc Up <850 V (L/N) <1,5 kV (L/PE) <1,2 kV (N/PE) Asymmetrical attenuation of filter (band-stop filter) Filters constraints min. 80dB at 4MHz min. 40dB (0,15 - 30MHz) Cx Cy L <2,2 W Power loss at winding temp. 20˚C Response time Part No. 30 080 tA <25ns (L/N) <100ns (L/PE, N/PE) Recommended backup fuse 6A Lifetime min. 100.000 h Weight m Part no 130g 30 080 Nominal voltage UN 230 V AC Max. continuous operating voltage Uc 275 V AC Nominal current IN 16A Nominal discharge current In(8/20) In 3 kA (L/N, L/PE) 5 kA (N/PE) Combined impulse Uoc 6 kV (L/N, L/PE) 10 kV (N/PE) Voltage protection level at Uoc Up <850 V (L/N) <1,5 kV (L/PE) <1,2 kV (N/PE) Asymmetrical attenuation of filter (band-stop filter) Filters constraints Part No. 30 004 150 nF 22 nF 1,2 mH min. 80dB at 4MHz min. 40dB (0,15 - 30MHz) Cx Cy L <3,5 W Power loss at winding temp. 20˚C Response time 220 nF 22 nF 1,8 mH tA <25ns (L/N) <100ns (L/PE, N/PE) Recommended backup fuse 16A Lifetime min. 100.000 h Weight Part no m 170/224g 30 004 15 2-Stage MOV Surge Arrester and EMC / EMI Filter Nominal voltage UN 230 V AC Max. continuous operating voltage Uc 275 V AC Nominal current IN 25A Nominal discharge current In(8/20) In 3 kA (L/N, L/PE) 5 kA (N/PE) Combined impulse Uoc 6 kV (L/N, L/PE) 10 kV (N/PE) Voltage protection level at Uoc Up <850 V (L/N) <1,5 kV (L/PE) <1,2 kV (N/PE) Asymmetrical attenuation of filter (band-stop filter) Filters constraints Part No. 30 017 min. 80dB at 4MHz min. 40dB (0,15 - 30MHz) Cx Cy L <3,5 W Power loss at winding temp. 20˚C Response time tA 25A Lifetime min. 100.000 h m Part no Nominal voltage UN 230 V AC Max. continuous operating voltage Uc 275 V AC Nominal current IN 32A Nominal discharge current In(8/20) In 3 kA (L/N, L/PE) 5 kA (N/PE) Combined impulse Uoc 6 kV (L/N, L/PE) 10 kV (N/PE) Voltage protection level at Uoc Up <850 V (L/N) <1,5 kV (L/PE) <1,2 kV (N/PE) Filters constraints min. 80dB at 4MHz min. 40dB (0,15 - 30MHz) Cx Cy L Response time 220 nF 22 nF 2,3 mH <4 W Power loss at winding temp. 20˚C tA <25ns (L/N) <100ns (L/PE, N/PE) Recommended backup fuse 32A Lifetime min. 100.000 h Weight Part no Surge Protection Specialists 240g 30 017 Asymmetrical attenuation of filter (band-stop filter) 16 <25ns (L/N) <100ns (L/PE, N/PE) Recommended backup fuse Weight Part No. 30 005 220 nF 22 nF 2,3 mH m 240g 30 005 Telephone/Fax/Modem Surge Arrester For BT Type Sockets. Test category D+C+B to BSEN 61643-21 Technical Data Part No. DTB2/ART Can also be used on ISDN Fast Transmission Lines Number of protected pairs 2 Nominal voltage Un 170v Max. continuous operating voltage Uc 204v Nominal current IN 100mA C2 Max. discharge current (8/20) 1MAX 2kA Nominal discharge current (8/20) IN 1kV Voltage protection level at 1kV/μs Up 520v Response time TA <30ns Data rate 10MBit/s Series impedance per line 1,5-10 Ω Parasitic capacitance C 1,5nF Operating temperature change ϑ -40°C ÷ + 80°C Category tested acc. to IEC 61643:21-2000 A2, B2, C2, C3, D1 Single or 10 Pair Telephone Surge Arrester for Installation into Krone LSA Disconnections Strips, Test Category D+C+B to BSEN 61643-21 Part No. DP1 LSA180 Part No. DP10LSA180 Part No. TELCO/EB Technical Data Nomincal direct voltage 110V= Max. continuous operating direct voltage (Uc) 180v= Max. continuous operating alternating voltage (Uc) 180~ Residual voltage at 1kV/μs <250V Nominal operating current at 25°C 145mA C2 nominal discharge current (8/20μs) In 5kA Max. impulse discharge current (8/20μs) (Imax) 10kA Protection level at In (Up) 220V Response time (tA) <1ns Thermal response time at 230V/23 A ac and ambient temp. 25°C (TA) <2s Capacitance wire-earth (C) <0.1nF Series inductance at 25°C (L) 47μH Series resistance per line at 25°C (R) 3-6 Ω Max. transmission frequency (fg) ≤1.2MHz Operating temperature range -40°C to + 80°C Enclosure material / colour Thermoplastic, grey or yellow Dimensions (L x W x H) 110 x 2.25 x 40mm Net weight / pc 90g 17 Data Signal Line Arresters/CCTV SP-30 SP-48 DATA SIGNAL ARRESTER 2 POLE Part No. SP5 SP12 SP15 SP24 SP30 SP48 SP60 SP110 Nominal voltage: Un 5V- 12V- 15V- 24V- 30V- 48V- 60V- 110V- Max. continuous voltage DC.Uc 6V- 14.5V- 17.8V- 26.8V- 34.8V- 55.1V- 65V- 170V- Max. continuous voltage: AC.Uc 4.2V 10.2V 12.5V 18.9V 24.5V 38.9V 50V 130V Nominal current: In 1A C2 Total Nominal Discharge Current In (8/20μs) 20kA D1 Total Lightning Impulse Current (10/350μs) Iimp 20kA Voltage protective level: Upin Voltage protective level: Up 1kc/μS Core/Core ≤50V ≤70V ≤85V ≤100V ≤130V ≤200V ≤240V ≤730V Core/PE ≤45V ≤60V ≤70V ≤80V ≤80V ≤120V ≤150V ≤400V Core/Core ≤16V ≤38V ≤50V ≤70V ≤95V ≤150V ≤180V ≤520V Core/PE ≤8V ≤19V ≤25V ≤35V ≤50V ≤75V ≤90V ≤260V 1.5 Ω 1.6 Ω 1.8 Ω 1.8 Ω 1.8 Ω 1.8 Ω Response time: tA ≤1ns Resistance 1Ω ≤25ns Insertion loss ≤0.3dB Working frequency ≤0.3MHz Degree of protection IP20 Dimensions 90H x 14W x 65D mm Enclosure material Polyamide PA6.6 Connector Screw terminals Signal Surge Protection Device. REP-SP Series Co-Axial BNC C.C.T.V Arrester Surge arresters for coaxial ethernet network systems protection. Protects against surges at the boundaries from lightning protection zone 0 3 • • • • • • 18 Data network protector in accordance with IEC614321. Limit the transients with gas discharge tubes and transzorb diodes. Two-stage protection circuit in aluminium housing. BNC connector for ethernet systems. Simple installation. Also application for the protection of video signals, cameras and/or TV systems Surge Protection Specialists Model No. D-24/BNC Nominal voltage (V) Un 24 Max. continuous voltage (V) Uc 24/28 C2 nominal discharge current (8/20μs) per line In 5kA C2 nominal discharge current (8/20μs) shield-PG In 10kA Voltage protection level (8/20μs, V) Up Line-Shield ≤300 Shield-Ground ≤700 Voltage protection level (1KVμs, V) Up Line-Shield ≤50 Shield-Ground ≤600 Transmission Speed (bps) Vs 10Mbps Series impedence per line (Ohm) 3Ohm Inerstion loss (dB) 0.5@10MHz Response time Ta 1ns Type of connection IN/OUT BNC Female/Male Dimensions (mm) 70x25x25 Environment Temperature °C -25~+70 Protection of PHOTOVOLTAIC/SOLAR SYSTEMS Surge protection devices for the protection of the DC side before inverter Type 2 to EN61643-11 • Fault indication • Remote signal contact optional • Pluggable and replaceable modules Part No. SPD PV1000 SPD According to IEC61643-1 EN61643-11 Type 2 Maximum continuous operating voltage UcV 1060v DC Voltage protection level In Up 4kv Nominal discharge current In (8/20μs) kA 20kA Maximum discharge current In (8/20μs) kA 40kA Withstand short circuit 50kA RMS Response time ns <25ns Dimensions W 54 x H 90 x D 66mm Din-rail mountable Enclosure material Grey UL94 V-O Degree of protection IP20 Recommended backup MCB/fuse 32A to 63A Terminal capacity Phase line Neutral line 2.5~35mm² Earth line 4.0~35mm² Signal line 1mm² Visual indication status Green - OK Red - Replace Module Din rail mountable Yes Type 2 to EN61643-11 SPD According to IEC61643-1 EN61643-11 Type 2 Maximum continuous operating voltage UcV 640v Voltage protection level Up 2.2kv Nominal discharge current In (8/20μs) kA 20kA Maximum discharge current In (8/20μs) kA 40kA Response time <25ns Dimensions W 36 x H 90 x D 66mm Enclosure material Grey UL94 V-O Degree of protection IP20 Recommended backup MCB/fuse 32A to 63A Terminal capacity • Fault indication • Remote signal contact optional • Pluggable and replaceable modules Phase line Neutral line 2.5~35mm² Earth line 4.0~35mm² Signal line 1mm² Visual indication status Green - OK Red - Replace Module Din rail mountable Yes Part No. SPD PV600 Type 1 + 2 Available - Please Contact The Sales Office 19 Lightning and Surge Protection for Industrial, Commercial and Domestic Electrical Insrtallations • • • We offer free technical help and assistance with product selection and design. We can carry out site surveys. We can assist with compliance to the latest requirement of the Wiring Regulations BS7671 and BSEN62305 Lightning Standards. TEL: FAX: EMAIL: 01484 851747 01484 852594 info@surgedevices.co.uk Surge Protection Devices Unit 1 Ash Royd Farm Royd Road Meltham Holmfirth West Yorkshire HD9 4BG www.surgedevices.co.uk Protection you can depend on...www.surgedevices.co.uk