ART. 19/13220 ÷ 19/13265 ELCART PAGINA 1 DI 2 Manuale di istruzioni/Scheda tecnica NEW LED TUBE SERIES Led Tube T8 Led Tube is an upgraded version CFL tube replacement with LED. It has the best configuration of brightness and power efficiency. Led Tube is designed to replace medium bi-pin T8 and T12 fluorescent tubes. Led Tube fits directly into most fluorescent fixtures providing a simple upgrade to high quality LED lighting. Led Tube is optimized to provide light outputs comparable to fluorescent and delivers the immediate benefits of white-LED lighting; long lifetimes, no maintenance, high efficency, no mercury, no recycling, no flickering, no buzzing, instant start, cold temperature operation, and high quality light. It provides energy savings of up to 75% over fluorescent applications that require long hours with low occupancy rates such as stairwells, corridors, warehouses, and remote locations. The high quality Led Tube replacement tube is constructed from extruded aluminum to provide a virtually unbreakable, vandal proof lighting solution. Why our Led Tube? • Much longer life than CFL tube • 70%~80% Energy-saving over Fluorescent tubes • Solid State, high shock/vibration resistant • Work without ballast, Instant soft-start • No RF interference, No fickering or buzzing • Quick and easy installation to minimize retrofit costs • Minimum maintenance costs, Produce little Heat • No Mercury and other hazardous materials, fully RoHScompliant • Rated to operate from -4°F to 104°F [-20°C to 40°C],perfect for environments with extreme climates • Epistar+Intermatix LED packaging solution, no patent trouble • The newest design • The best cost-effective • Complete electricity isolation design, safety prov • ETL certification Technical Parameters • Standard lenght (see below page size) • Rated input voltage 100-240V AC, 50-60Hz,maximal input voltage 277V AC. • PF (power factor) >0.9 • Light efficiency > 95 lm/W (clear and wave cover) Dimensions (Unit: mm/inch) Applications parking lot office RoH S COMPLIANT residential railway station warehouse signage bus Longlife ELCART DISTRIBUTION SPA via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY Tel. +39 02.25117310 Fax +39 02.25117610 sito internet: www.elcart.com e-mail: info@elcart.it La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto. The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product. La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto. ELCART ART. 19/13220 ÷ 19/13265 PAGINA 2 DI 2 Manuale di istruzioni/Scheda tecnica Specifications Led Tube has 2 types according to its front shells. Model Number Color 19/13225 19/13222 19/13220 19/13245 19/13242 19/13240 19/13265 19/13262 19/13260 Frosted Cover Warm White Natural White White Warm White Natural White White Clear Warm White Natural White White Lenght Power (W) 600mm 9W 1200mm 18W Light output (LM) ±5% 930 948 978 1500 1688 1718 1783 1978 2211 Cover 1500mm 22W Installation Drawing Ho w to instal l LE DT ube ? AC 100-240V AC 100-240V AC 100-240V Installation Inductive Ballast Remove the Inductive ballast Inductive Ballast L N AC110V/220V G13 Lamp holder G13 Lamp holder L N L N G13 Lamp holder G13 Lamp holder AC110V/220V Fluorescent tube G13 Lamp holder AC110V/220V Fluorescent tube G13 Lamp holder Fluorescent tube Delete the starter S S Step 1 Step 2 Step 3 Normal fluorescenttube T8 LED tube Takedwon Normal fluorescenttube Remove ballast and do it without Open the house cover Step 1 Step 2 Cut out the wire of nouse Insatall T8 LED tube Power Power Come back the house cover Connect lead wirebyconnector Power 100~240V Step 3 Step 4 Notice Installation information: Power must be cut off before installation, fix it on the position of installation holes, connection of the power supply must be sealed. 1.Please read the specification first, to make sure the service environment matches the condition in the specification before using. 2.Please confirm the applicable power supply before using. 3.Make sure the switch of product is off before connect to the power supply to prevent electric shock. 4.Operation against rules may damage your property even harm to your personal safety. 5.Preliminarily estimate required quantity of LED lights, then according to the power rating of single flood light to figure out the total power and design power supply plan. 6.Dangerous high voltage, Non-professionals are not allowed to maintain the products. If the exterior flexible cable or wire is damaged, it must exchange by the supplier, its agent or other similar qualified personnels to avoid dangers. ELCART DISTRIBUTION SPA via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY Tel. +39 02.25117310 Fax +39 02.25117610 sito internet: www.elcart.com e-mail: info@elcart.it La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto. The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product. La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.