On Grid Non Feed and Feed Cable Installation Instructions
On
Grid Non Feed and Feed Cable Installation Instructions
For 1” T-Grid, 9/16” T-Grid and Screw Slot Grid Ceiling Systems
For 1" T-Grid, 9/16" T-Grid and Screw Slot Grid Ceiling Systems
WARNING
To Reduce Risk Of Death, Injury Or Property Damage From Fire, Electric Shock And Other Hazards:
WARNING
-Service of equipment must be performed by qualified personnel.
TO REDUCE RISK OF DEATH, INJURY OR PROPERTY DAMAGE FROM FIRE, ELECTRIC SHOCK AND OTHER
-Installation and maintenance must be performed by qualified personnel familiar with the construction and operation of
HAZARDS:
this product and any hazards involved. All applicable local and national codes and ordinances must be followed.
Service of equipment must be performed by qualified personel.
-Read this document before installing, servicing or maintaining this equipment. These instructions do not cover all
Installation
maintenance
mustsituations.
be performed
by qualified
personnel
with
the construction
and operation of
installation,and
service
and maintenance
If your situation
is not covered,
or, iffamiliar
you do not
understand
these
or need
information,
Lumato Lighting
or your
local Lumato
Lighting
distributor. must be followed.
thisinstructions
product and
anyadditional
hazords
involved.contact
All applicable
local and
national
codes
and ordinances
Read this document before installing, servicing or maintaining this equipment. These instructions do not cover all
installation,
service and maintenance situationS. If your situation is not covered, or, if you do not understand these
WARNING
instructions or need additional information, contact Lumato lighting or your local Lumato Lighting distributor.
Before Installing, Servicing Or Maintaining This Equipment, Follow These General Precautions To
Reduce The Risk Of Electrocution:
WARNING
-Make sure the equipment is properly grounded.
BEFORE INSTALLING, SERVICING OR MAINTAINING THIS EQUIPMENT, FOLLOW THESE GENERAL
PRECAUTIONS.
TO REDUCE
THEequipment
RISK OFbefore
ELECTROCUTION:
-Always de-energize
the circuit and/or
connecting to, disconnecting from or servicing the
equipment.
Make
sure the equipment is properly grounded.
Always de-energize the circuit and/or equipment before connectiong to, disconnecting from or servicing the
To Prevent Luminaire Row From Over-Current:
equipment.
-By adding the input current of each luminaire section marked on the luminaire, the total current per power feed must
TO PREVENT
LUMINAIRE
ROW
FROM OVER-CURRENT:
not exceed the
maximum line
wire amperage
rating in the luminaire and the power feed cord/wire amperage rating
is least.
Bywhichever
adding the
input current of each luminaire section marked on the luminaire, the total current per power feed must
not exceed the maximum line wire amperage rating in the luminaire and the power feed cord/wire amperage rating
whichever is least.
CAUTION
CAUTION
It Is The Installers Responsibility To Ensure That Wall, Ceiling Or Junction Box Is Structurally
Of Supporting
Weight
Ofwall,
Luminaire/Luminaire
Row.
It isCapable
the installers
responsabiltyThe
to ensure
that
ceiling or junction box
is structurally capable of supporting the
weight of luminaire/luminaire row.
1” T-GRID
T-GRID (T1)
1"
(T1)
9/16”
T-GRID (T9)
(T9)
9/16"
T-GRID
SCREW
GRID
(SC)
SCREW
SLOTSLOT
GRID
(SC)
SAVE THESE INSTALLATION INSTRUCTIONS
SAVE THESE INSTALLATION INSTRUCTIONS
Lumato 1035 DAIRY ASHFORD - HOUSTON, TEXAS 77079
Tel (832) 230-3165
www.lumatolighting.com
LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT
DESIGN AND SPECIFICATIONS. CONTACT FACTORY
FOR MOST RECENT PRODUCT INFORMATION.
7500002-1 8/14
LUMATO
1035 Dairy Ashford - Houston, Texas 77079
Office: 832.230.3165
www.lumatolighting.com
LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT
DESIGN AND SPECIFICATIONS. CONTACT FACTORY
FOR MOST RECENT PRODUCT INFORMATION.
7500002-1 8/14
Lumato
Light Without Boundaries
On Grid Non Feed Cable Installation Instructions
For 1” T-Grid, 9/16” T-Grid and Screw Slot Grid Ceiling Systems
NON FEED CABLE/CANOPY ASSEMBLY
Step One:
-Determine mounting cable spacing centers from factory shop drawing or order processing specification sheet.
Step Two:
-Installation
of IDS clip onto T-BAR at appropriate locations (REF. STEP 1 AND FIG. 1)
A. Assemble 1/4-20 stud and clip. Start stud into recessed square hole, grasp clip in hand and depress tab a with thumb.
Pull stud into place and release TAB A.
B. Separate clip into it’s two parts by bending at TAB B.
C. Place PART X on T-BAR and insert base tab on part into slot. Close PARTS X and Y together locking with TAB C.
Step Three:
-Secure IDS clip to structural support above with minimum #12 gauge support wire in accordance with local codes. (REF FIG. 2)
Step Four:
-Insert cable supplied in kit through ceiling coupler in kit and attach to 1/4-20 stud on IDS clip securely. Remove threaded
canopy support ring from coupler and slide canopy then support ring over cable and up to finished ceiling line. Tighten
support ring to locate canopy in place.
Step Five:
-Raise luminaire to cable assembly and route cable through the center of the adjustable cable fitting loosening the locking
cap enough to allow cable to enter fitting. Feed cable through the adjustable fitting until desired mounting height is attained.
Luminaire will be retained at the last point of adjustment. Tighten locking cap onto retainer stem.
Note: If It Becomes Necessary To Re-Adjust Luminaire Height, Loosen Locking Cap And Depress
Retainer Stem While Adjusting To Desired Position.
CAUTION
Be Certain To Support Luminaire Independently Of Cables When Depressing Retainer Stem.
FIGURE 1
A
FIGURE 2
#12 GA Support Wire to Structure Above (By Others)
B
Tab A
Part Y
1/4-20 Stud
Part X
Tab B
Ceiling Lines
T-Bar Suspension Clip
C
Part X
Part X
Cable Barrel
Tab C
T-Bar
Non-Feed Canopy
1/16” Galvanized Steel Cable
Cable Barrel Support Ring
Base Tab
Locking Cap
Retainer Stem
Lock Nut
Adjustable Cable Fitting
LUMATO
1035 Dairy Ashford - Houston, Texas 77079
Office: 832.230.3165
www.lumatolighting.com
LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT
DESIGN AND SPECIFICATIONS. CONTACT FACTORY
FOR MOST RECENT PRODUCT INFORMATION.
7500002-2 8/14
Lumato
Light Without Boundaries
On Grid Feed Cable Installation Instructions
For 1” T-Grid, 9/16” T-Grid and Screw Slot Grid Ceiling Systems
FEED CABLE/CANOPY ASSEMBLY
Step One:
-Determine mounting cable spacing centers from factory shop drawing or order processing specification sheet.
Step Two:
-Installation of IDS clip onto T-BAR at appropriate locations on T-BAR. Follow instruction sequence #2 and 3 from previous page.
Step Three:
-Install Greenfield connector or equal (by others)onto junction box. Attach Junction Box and Junction Box support bracket
to IDS clip with 1/4-20 nut and bolt provided as illustrated.
Step Four:
-Support Junction Box support bracket to structural support above with minimum #12 gauge support wire in accordance with
local codes as illustrated.
Step Five:
-Cut a 3/4” dia. hole in ceiling tile aligned with Greenfield connector protruding from Junction Box. Insert cable supplied in kit
through ceiling coupler in kit and attach to 1/4-20 stud on IDS clip securely. Remove threaded canopy support ring from
coupler and slide canopy then support ring over cable and up to finished ceiling line. Tighten support ring to locate canopy in
place.
Step Six:
-Raise luminaire to cable assembly and route cable through the center of the adjustable cable fitting loosening the locking
cap enough to allow cable to enter fitting. Feed cable through the adjustable fitting until desired mounting height is attained.
Luminaire will be retained at the last point of adjustment. Tighten locking cap onto retainer stem.
Note: If It Becomes Necessary To Re-Adjust Luminaire Height, Loosen Locking Cap And Depress
Retainer Stem While Adjusting To Desired Position.
CAUTION
Be Certain To Support Luminaire Independently Of Cables When Depressing Retainer Stem.
Step Seven:
-Route feed cord from luminaire through grommeted hole in canopy and into Junction Box. Connect feed cord to incoming
power feed wires within Junction Box with appropriate connectors and install cord restraint as illustrated. Attach supplied tie straps
around feed cord and cable at a minimum of 36” on center.
-ENERGIZE AND CHECK FOR PROPER OPERATION.
ILLUSTRATION ON NEXT PAGE
LUMATO
1035 Dairy Ashford - Houston, Texas 77079
Office: 832.230.3165
www.lumatolighting.com
LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT
DESIGN AND SPECIFICATIONS. CONTACT FACTORY
FOR MOST RECENT PRODUCT INFORMATION.
7500002-3 8/14
Lumato
Light Without Boundaries
On Grid Feed Cable Installation Instructions
For 1” T-Grid, 9/16” T-Grid and Screw Slot Grid Ceiling Systems
#12 GA Support Wire to Structure Above (By Others)
J-Box Support Bracket
T-Bar Suspension Clip
4” Octagonal J-Box (By Others)
Cord Restraint
1/4-20 Nut
Ceiling Line
Feed Cord; Installed on Fixture
Cable Barrel
Bushing
4” Canopy (Feed)
1/16” Galvanized Steel Cable
Cable Barrel Support Ring
Pull Tie Strap
Locking Cap
Retainer Stem
Bushing
Cord Restraint
Lock Nut
Adjustable Cable Fitting
LUMATO
1035 Dairy Ashford - Houston, Texas 77079
Office: 832.230.3165
www.lumatolighting.com
LUMATO RESERVES THE RIGHT TO CHANGE PRODUCT
DESIGN AND SPECIFICATIONS. CONTACT FACTORY
FOR MOST RECENT PRODUCT INFORMATION.
7500002-4 8/14
Download