Fans | Air Handling Units | Chillers & AC | Air Distribution Products | Fire Safety | Air Curtains and Heating Products Residential Ventilation Systems SaveVent Comfort - intelligent ventilation solutions by Systemair 2 | Discover the secret of fresh air air! Discover the secret of fresh air! Since 1974 Systemair cares for the purity of an essential resource. Today Systemair is one of the leading ventilation companies worldwide. A success story, which started in Skinnskatteberg, Sweden, with the invention of the inline duct fan. This invention revolutionised the ventilation world. Discoverthe thesecret secretof offresh freshair! air | Discover Contents Discover the secret of fresh air! 2 SystemairFlex+ „The NEW semi-rigid ducting“ 84 Systemair worldwide 4 Circular ducts, galvanized 91 94 Supply your customers with energy from the earth 18 Flat ducts, Plastic & metal flat oval Make household chores fun again 19 ISO+ ducts 101 Efficient exhaust ventilation systems 20 Silencers 102 Energy efficient EC fans 24 Fresh and exhaust air grilles 104 Fan Accessories 30 Diffusers 106 EC-Vent Controls 35 Self regulating extract air valves 110 Domestic / Commercial fans 40 Self regulating fresh air valves 113 High efficient heat recovery systems 46 Air volume controllers / Fire Dampers 115 Functional Principle Heat Recovery 58 GEO Geothermal heat exchanger unit 118 Overview Residential Ventilation Units 50 Central Vacuum Systems 120 Systemair Duct Systems 82 Combi Whole House „Genius“ unit 122 Since then, the company has been constantly developed and provides nowadays a complete product range for ventilation technology that sets standards. Whether it is a ventilation concept of a shopping mall, a controlled domestic room ventilation system of a single-family house or the ventilation of tunnels and metro stations - Systemairs’ experts know the requirements and exactly what is needed. More than 2500 employees in more than 60 subsidiaries and 40 countries provide the required customer focus. We invite you to discover the world of ventilation technology in this brochure together with us. Our Residential Systems Team at Oxford are ready to answer all questions concerning the ventilation subject. 3 4 | Systemair worldwide Systemair worldwide Skinnskatteberg, Sweden: Systemair AB, the Systemair group head office is in Skinnskatteberg, Sweden. The production is virtually fully automated with modern machinery featuring advanced computer support. Also located here is the company's most advanced test installation for measuring technical data. Windischbuch, Germany: Production facility for fans and modular air handling units, specialized on engineered products (e.g. tunnel and jet fans). Distribution center. Hässleholm, Sweden: VEAB is the leading European manufacturer of electric duct heaters. Production of heating and cooling coils, electric and water based. Ukmerge, Lithuania : Production of smaller air handling units with energy recovery systems. Maribor, Slovenia: Specialized in centrifugal smoke extract fans, EN certified. Hasselager, Denmark: Production of modular air handling units. Bratislava, Slovakia: The factory in Bratislava manufactures air distribution products and EN certified fire and smoke dampers. Systemair worldwide | Quality: Systemair is certified in accordance with ISO 9001; ISO 14001 and ATEX. Our research and development laboratories are one of the most modern in Europe; measurements are made in accordance with international standards like AMCA and ISO. Dal, Eidsvoll, Norway Hasselager, Denmark Bouctouche, Canada Kansas City, USA Langenfeld, Germany Windischbuch, Germany Madrid, Spain Save energy, lower running cost! Our label "Green Ventilation" features products with a high energy saving potential.All products labelled with "Green Ventilation" combine energy economy with energy efficiency. Skinnskatteberg, Sweden Hässleholm, Sweden Ukmerge, Lithuania Bratislava, Slovakia Maribor, Slovenia Milano, Italy New Delhi, India Hyderabad, India Kuala Lumpur, Malaysia Kuala Lumpur, Malaysia : Manufacturing of products for the Asian market. Madrid, Spain: Production of air handling units. Dal, Eidsvoll, Norway: Production of air handling units for the Norwegian market. New Delhi, India: The factories in New Delhi and Noida manufacture grilles and diffusers. Systemair Software is also based here. Bouctouche, Canada: Our main North American production facility of air handling units and inline fans for commercial and residential applications is located in Bouctouche. Kansas City, USA: Production of fans for the US market. Milan, Italy: Our factory in Italy, Systemair AC, develops and manufactures a wide range of chillers. 5 Take a deep breath and enjoy the pure, fresh air of your surroundings. With each breath, you unwind a little bit more and begin to feel fully at ease. You’ve finally arrived. Make the dream of modern living a reality with intelligent concepts from Systemair - Villavent, increasing living quality which in turn helps to save energy and the environment Transform your home into a day-spa of fresh filtered air. 8 | Principle Quality of life starts with the climate Residential ventilation by Systemair Those wishing to build or carry out renovations today are faced with a challenge. The current building regulations demands better insulated and air-tight buildings in order to protect our resources and the environment. Air-tight well insulated buildings prevent natural ventilation through the buildings component parts, which could result in the formation of mould through damp stagnant stale air, which is detrimental to both the building structure and the health of the occupants. The solution is The SaveVent Comfort -controlled room ventilation by Systemair. Room ventilation of the highest standard For over 35 years now, we here at Systemair have been making energy efficient clean air a reality. Be that in large shopping centres, hospitals or simply in the confines of your home. With SaveVent Comfort, we offer you a system which lets you enjoy fresh air around the clock, without having to lift a finger. This is because the air exchange occurs automatically and, importantly, is regulated. Opening the windows for a quick airing-out is no longer necessary. Not only is this very convenient, you also save both money and energy in the process. Why? Because the heating energy stays where it’s supposed to: in the house. This is especially the case with heat recovery. In this process, the waste air is extracted and used for tempering the cool fresh air, unsightly trickle ventilators, causing draughts, become a thing of the past. One of life’s luxuries Along with used stale air, SaveVent Comfort also expels excessive air moisture. This way, you can enjoy a pleasant environment without condensation and mould being eliminated. Not only does this protect the basic fabric of the building, it protects the occupants’ health as well. Just as beneficial to their well-being are our high-quality pollen and dust filters. Even people with allergies can now breathe a sigh of relief with the seal of approval from the British Allergy Foundation. This is how your controlled room ventilation works: The extract fan within the ventilation system extracts air from the wet rooms (kitchen, bathroom, WC) on an continual basis. Depending on the system, a heat exchanger extracts the heat Principle | from waste air first. At the same time, fresh air from outside is taken in and filtered. If necessary, the heat exchanger pre-tempers the cool outside air using the waste air. The fresh air then flows through the vents into the rooms. From there, the supply air flows to the living areas via the landing and hallway and into the kitchen bathroom and WC. This way, the two different air streams don’t mix. The result being an optimum room environment. 9 10 | Solution Creating a good atmosphere is a matter of trust SaveVent Comfort A room’s climate is not a constant, instead it depends on a number of factors, for example, room moisture, CO2 saturation, the size of the room as well as the number of people in the room and how long they stay there. All these factors are taken into account with a correctly sized Systemair ventilation system. A system which is perfectly tailored to your clients’ needs and buildings, regardless of whether it’s a new build or renovation work. In short: a system like SaveVent Comfort. Optimum planning In close collaboration with you, we plan your personal room ventilation options. Based on our calculations and our decades of experience, we put together the SaveVent Comfort system components for you. Of course, we take into account the specific wishes of your clients when doing so, perhaps they want a ventilation system with geothermal heat-exchanger for example (see p. 20). So what does it all mean? It means you can guarantee complete satisfaction at all times. Intelligent room ventilation Sensors determine the exact degree of ventilation necessary according to building usage. Subsequently, the intensity of ventilation is monitored effectively, that is, the rotation of the fan is adjusted to meet the requirements necessary at any specific time. This means that the system isn’t always running at full speed. Similarly, preheating the fresh air is only done when needed. This way, your energy costs can be considerably reduced. And since the control mechanism responds without delay, the occupants can enjoy a balanced and healthy, energy efficient indoor environment 24/7. Intelligent technology you can trust from Systemair. kWh/Jahr 10000 8000 6000 100 % 83 % 4000 42 % 2000 0 Modern living needs the proper living space ventilation: SaveVent Comfort Fensterlüftung Raising quality of life – Reducing168 heating costs! m2 Wohnfläche Abluftanlage Wärmerückgewinnung 10 kWh = 1 Liter HEL oder 1 m3 Erdgas Quelle: Hessisches Ministerium für Wirtschaft, Verkehr und Landesentwicklung kWh/year 10000 8000 6000 100 % 83 % 4000 42 % 2000 0 Ventilation through windows 168 m2 living area Exhaust system System with heat recovery 10 kWh = 1 litre fuel oil or 1 m 3 natural gas Source: Hessian Ministry of Economics and Transport, Germany 12 | PlanCal Nova CAD planning for ventilation systems Systemair runs a special design office for room ventilation systems. These planners are well-trained especially for ventilation in rooms and are able to plan and to offer the most suitable ventilation system for you. We use the planning software Plancal: Plancal-Nova is a stand-alone drawing software for HVAC. It requires no other CAD applications and is widely used in the HVAC sector. Plancal-Nova can import and modify drawings from other architecture or drawing software and export them again. Plans can be read and created in 2D as well as in 3D. Visualisation methods of projects: 2D for ground plans or 3D models with or without building. Unclear details can be displayed as sections or 3D details. 3D models offer different perspective views or allow you to take a virtual tour through a building. Systemair data set Systemair has created a data set for this software with some specific features: Plancal Nova uses components of the Systemair room ventilation product range and allows calculating the planned system by using the determined air volume with regard to pressure losses of the unit up to the outlets. The determined operation point helps calculating the data of the unit, such as power consumption and sound emission. Plancal Nova can also calculate noise reduction of the duct system from the unit up to the outlets. Therefore, noise problems can be detected early and prevented during the planning phase. After planning, a suitable bill of materials with Systemair article numbers can be generated to make a detailed offer. The CAD plans can also be used to release installation plans with specified information concerning duct installation inclusive legends and identification marking in colours. This considerably facilitates the installation. This planning documentation ensures an easy inspection because the duct installation can be quickly reproduced. Important flow information of the system will be automatically listed on printouts. This wide planning service is currently unique and guarantees safety from tender phase to commissioning. 14 | Components Perfectly in tune with your customers The SaveVent Comfort Systems Without heat recovery SaveVent Basic Efficient exhaust ventilation system with manual air flow control SaveVent Basic + Efficient ventilation system with intelligent control With heat recovery In the basic model, the used indoor air is sucked out. Fresh air flows in through the external wall vents. As such, continuous ventilation of the entire home is assured. Ventilating rooms is even easier with the EC vent. This intelligent control unit can regulate ventilation according to the current CO2 saturation, room temperature, humidity and the number of people in the room. Using these parameters it determines the necessity for ventilation and regulates the volume of air. All of it is done automatically. SaveVent Comfort C Highly efficient ventilation with counter flow heat exchanger With a reverse flow heat exchanger your customers can achieve the highest degree of heat recovery. The system automatically switches between normal mode with heat recovery and summer mode without it. In Summer a bypass function overrides the heat recovery. SaveVent Comfort R Highly efficient ventilation with rotary wheel heat exchanger Your customers want maximum convenience with minimum heat loss? Then recommend them our rotational heat exchanger system. This extracts the heat from the waste air and pre-tempers the cool fresh air. Some of the humidity of the air is also recovered and transferred to the supply air. High-quality fine particle filters make sure the air stays pure. Components | With SaveVent Comfort, you are able to enjoy continuous fresh air in the home. Even with our basic configuration, you can enjoy the best climate conditions. The benefits: tailored aeration and ventilation energy-saving low operating costs simple installation user-friendly quiet-running long life The benefits: controlled aeration and ventilation as needed intelligent control energy-saving, low operating costs easy installation quiet-running long life user-friendly menu navigation day/night operation set by timer The benefits: controlled aeration and ventilation heat recovery degree of up to 90% bypass function automatic de-icing function extreme energy savings quiet-running user-friendly optional fine particle filter The benefits: controlled aeration and ventilation heat recovery degree of up to 85% Summer bypass function extreme energy savings quiet-running allergy-friendly humidity recovery, thus consistently pleasant indoor climate Comfort which can be improved on even further: with components which automatically manage the supply of fresh air and save on energy too. Could there be such a thing as too much convenience? Systemair duct systems Multiple options available Systemair air distribution products Ceiling or wall mounted. For whichever convenient ventilation system your customers choose and regardless of their structural circumstances, with our ductwork systems you rise to every challenge. Do your customers prefer modern living? What about classical, maybe elegant or perhaps they prefer the style of the country house? Regardless of which fittings your clients like, they’re bound to find the design they’re looking for in our versatile range of highquality ceiling and wall vents. Whether from galvanised steel sheeting or polymer, whether round or oval, all pipes are extremely robust, resistant to deformation and, if necessary, easy to clean. Your clients can make the selection and choose the size to meet their individual requirements. This guarantees the safe and economical distribution of air through the building. Simply show your customers the models in our catalogues or refer them to our website. www.systemair.co.uk 15 Service | Something you can Trust Your “all-round worry-free package” from Systemair For whichever configuration level you choose, in SaveVent Comfort you are getting room ventilation of the highest quality. This is because we place the greatest emphasis on quality, functionality, efficiency and energy conservation when developing our products. And since we only want to offer you the absolute best, we put our innovations through their paces before they reach you. Our Research and Development Centre in Sweden is one of Europe’s most state-of-the-art test laboratories for ventilation technology. Expert advice from the start It goes without saying that such a high-quality system also comes with high-quality service. As such, we make ourselves available to you with our helpful advice during the planning and tendering process. Using the building plans we determine your required air quantity. The basis for this are the current building regulations. We then plan your entire ventilation system using our experience and the latest CAD programmes. This way, you can be sure that your system and all of its components are optimally coordinated with the building. We also make it easy for you to put together an offer: This enables us to provide you with a straightforward offer for the supply of all necessary materials, installation and commissioning (as appropriate). This “One-Stop-Shop” enables you to have peace of mind that any grey areas that would otherwise occur between the supply, installation and commissioning are taken care of by the same organisation. Provided the system is constructed Systemair Since 1974, Systemair has been making clean air reality. In the meantime, our company has established itself as one of the global market leaders in the area of ventilation technology. A success story which began in Skinnskatteberg in Sweden and continued rapidly with the invention of the duct fan. Today, we develop ventilation technology which sets new standards. Be it for major projects like shopping centres, tunnels or underground train stations, or for smaller undertakings for room ventilation in family homes, our experts know what matters. according to plan, we will of course offer a warranty for its proper functioning. We also take great care to ensure that our products are delivered quickly and are easy to assemble. This not only simplifies the work for you, it also reduces both the construction time and the costs for your clients, which they will no doubt appreciate. (should you choose to install yourselves). If necessary, we also help you during the commissioning and adjustment of the system. We can also thereafter provide an annual service of the system. With our filter subscription, for example: You can maintain a healthy room climate and keep energy consumption down. We are happy to automatically deliver new filters for the system on a regular basis. Our allround worry-free service makes it easy. If you have any difficulties starting up the system or general questions on room ventilation, give us a call! 01993 778481 Our technical support hotline is available Mon-Fri from 8:30AM to 5:00 PM. Tel: 01993 772270 17 18 | Supply your customers with energy from the earth Supply your customers with energy from the earth With Geo, our brine geothermal heat exchanger Do you want to improve the level of efficiency of your ventilation unit? Do you want a pleasant indoor room climate for relaxing on hot summer’s days? Then why not simply use geothermal heating from Systemair. Not only is it available all the time for free, it helps you save on your energy costs too. The temperature in the earth is practically constant throughout the year. As such, it’s suitable for preheating the cold outside air in winter with the help of a heat exchanger. Then in summer, the warm air can be cooled down before it reaches your home’s interior. The heat exchanger’s piping needs to be buried at a depth of 1.5 to 2 meters. This is the only way to ensure that a large enough temperature gradient occurs. Since we only want to provide your customers with the best in this area too, we have developed “Geo”. With this geothermal heat exchanger, the heat or coolness of the earth first passes into the brine (water with antifreeze agent). Only after it has arrived in the basement is it transferred to the supply air using a heat exchanger. The clear advantage with Geo Unlike the air duct geothermal heat exchanger, with Geo the air is not drawn in through underground pipes. Not only is this more hygienic, it does away with the otherwise necessary regular cleaning. On top of that, Geo is better value and more robust than the air duct system. This is because the piping can have much smaller dimensions (Dia 32 instead of Dia 200). This also means that it is easier to install. Furthermore, the brine system is easier to manage. Your customers decide at what outside temperatures Geo should start up. This conserves the supply of geothermal heat and gives you exactly the room climate you want. The forward-looking way to use energy: Systemair “Geo” Central vacuum cleaner | Make household chores fun again Villavent Central Vacuum Cleaner You will no doubt want to keep up with the times when it comes to household chores too and ensure the greatest convenience possible. So why not install our Villavent Central Vacuum Cleaner! With this system, all you have to do is insert a suction hose into a socket in the wall and then can get started straight away. No more pulling around a clunky machine behind you, which often likes to get caught on valuable pieces of furniture, leaving behind ugly marks. And no more need to carry heavy items from floor to floor in order to vacuum clean. Household chores really can be this easy. Incredible suction. Incredibly quiet. This helps your customers maintain a healthy room climate with clean air. For one, its very strong suction guarantees maximum cleaning of furniture, floor and rugs. For the other, sucked in dirt is sped directly into the vacuum cleaner bag of the central device. This can be mounted in a utility room like the basement or garage. This means that the vacuum cleaner is extremely quiet and you don’t have any annoying background noise in the rooms of your house. Additionally, the central device blows the waste air directly to the outside. This ensures that dust doesn’t swirl up in your utility room - meaning that time is saved when cleaning and those with allergies don’t have to worry. Equipped with a Hepa filter, the vacuum cleaner is even suited to passive houses whose building envelope cannot be cut through by air discharge openings. The long, flexible suction hose comes equipped with a telescopic pipe and floor nozzle. This means your customers can work in ease and give their backs a break. Maintenance of the central vacuum cleaner is generally limited to regular cleaning of the suction casing and replacing the filter bags.as required. Vacuum-cleaning today:Villavent central vacuum cleaner 19 20 | Exhaust fan unit Systemair Residential Ventilation Systems Efficient exhaust ventilation systems from Systemair Without heat recovery Systemair duct systems Extremely flexible SaveVent Comfort Basic Efficient exhaust ventilation system with manual air flow control SaveVent Comfort Basic + Efficient ventilation system with intelligent control Overview SaveVent Comfort applications SaveVent Comfort Basic Basic Basic+ Basic+ Application Single family house Flat Single family house Flat System Extract only Extract only Extract only Extract only Location Roof Space / Loft Roof Roof Space / Loft Roof Ventilation unit Extract fan: KVKE EC, Controller EC-Vent Extract fan: TFSK Extract fan: KVKE EC; Controller EC-SaveVent Extract fan: TFSK; Controller EC-SaveVent Extract valves in bathroom, toilet and kitchen; products: valves in bathroom, toilet and kitchen; products: valves in bathroom, toilet and kitchen; products: valves in bathroom, toilet and kitchen; products: valves Intake valves Windows and FAV Windows and FAV Windows and FAV Windows and FAV * ducting with air volume control Exhaust fan unit | Systemair Residential Ventilation Systems General description • Exhaust air units are the most cost-efficient method of mechanical ventilation. • Exhaust air units consume less electrical power because only the fan needs energy. • However: no heat recovery and no pre-heating of supply air ! Systemair air distribution products Just your style Function The used, humid and polluted room air in exhaust air rooms such as kitchens, bathrooms and toilet rooms is exhausted by a ventilator through a duct system and led via roof or facade to the outside. Fresh air enters living rooms, children‘s rooms and bedrooms via facade inlets (valves with filter in the facade) and ensures continuous aeration of the whole apartment. The controlled room ventilation reduces ventilation heat losses compared to conventional aeration by open windows. Building Regulations -Part F Ventilation 2010 Table 5.1a Extract Ventilation rates Room Intermittent Extract Minimum Rate Continuous Extract Minimum High Rate Kitchen 30l/s adjacent to hob; or 60 60l/s elsewhere 13l/s Utility room 30l/s 8l/s Bathroom 15l/s 8l/s Sanitary accommodation 6l/s 6l/s Minimum Low Rate Total extract rate should be at least the whole dwelling ventilation rate given in Table 5.1b Table 5.1b Whole dwelling Ventilation rates 1 Whole dwelling ventilation rate a,b (l/s) 13 Number of bedrooms in dwelling 2 3 4 17 21 25 5 29 Notes: a. In addition, the minimum ventilation rate should be not less than 0.3l/s per m2 of internal floor area. (This includes all floors, e.g. for a two-storey building add the ground and first floor areas) b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected add 4l/s per occupant. 21 22 | Exhaust fan unit Exhaust air unit in a single-family house Advantages for a single-family house • Cost-efficient method • Smaller duct system Disadvantages for a single-family house • No heat recovery • No pre-heating supply air • Only rough filtration of the fresh air possible Exhaust air unit in an apartment building, centrally Advantages for an apartment building • Low maintenance costs • Less power consumption - only one fan Disadvantages for an apartment building • No heat recovery • No pre-heating supply air • Only rough filtration of the fresh air possible • Fire safety and noise protection measures have to be respected. Systemair Residential Ventilation Systems Exhaust fan unit | Systemair Residential Ventilation Systems Exhaust air unit in an apartment building, decentrally Advantages of exhaust air for each apartment • Individually controllable • Clear costs • Exhaust air via facade: no noise protection and fire safety measures to the neighbour necessary Disadvantages of exhaust air for each apartment • Facade breakthrough in each apartment • No heat recovery • No pre-heating supply air • Only rough filtration of the fresh air possible Conclusion: Exhaust air units meet the requirements according to EnEV (German Energy Savings Act) and DIN 1946-6, but cold supply air from the outside offers less comfort. In addition to this, filtering of the supply air is limited. The main advantages are cost-efficient acquisition costs and installation. 23 24 | Exhaust fan unit Systemair Residential Ventilation Systems KVKE EC • EC-motors, high level of efficiency • 100% speed controllable • Speed regulator included • Low sound level • Integrated motor protection • Potentiometer included for ease of commissioning The KVKE EC models have a single inlet centrifugal fan with backward-curved blades and a maintenance-free external rotor motor(EC). These fans develop relatively high static pressure and have a very high efficiency. The fans are delivered with a prewired potentiometer (0-10V) that allows you to easily find the desired working point. The KVKE motor and impeller are mounted on the access cover for ease of maintenance. The service cover can be easily removed by withdrawing the hinge pin. Motor protection is integrated in the electronics of the motor. The fans can be installed in any position and are easy to connect to spiral ducts using FK mounting clamps. The KVKE models are manufactured from galvanised sheet steel and are thermally and acoustically insulated with a 50 mm layer of rockwool with a surface liner which prevents the migration of fibres into the airstream. Performance SAP Appendix Q (*KVKE 125 EC Fan) 1 2 Exhaust Terminal Configeration Specific Fan Power (W/l/s) Energy Saving Trust Best Practise Performance compliant Kitchen +1 Additional wet room 0.25 Yes Kitchen +2 Additional wet room 0.27 Yes Kitchen +3 Additional wet room 0.30 Yes 3 4 5 1 2 3 4 5 Kitchen +4 Additional wet room 0.35 Yes Kitchen +5 Additional wet room 0.42 Yes Kitchen +6 Additional wet room 0.53 Yes Technical data KVKE * 125 EC 160 EC 200 EC 250 EC 315 EC Art no. 2570 2571 2575 2577 2578 V/50 Hz 230 230 230 230 230 Power W 68.7 67.8 156 265 395 Current A 0.536 0.53 1.10 1.64 2.38 Voltage/Frequency Max air flow m3/hr 374 544 864 1156 1865 R.p.m. min-1 3339 2592 3033 2821 2380 Max temp. of transported air °C 60 60 60 55 45 “ when speed controlled °C 60 60 60 55 45 dB(A) 41 39 46 49 50 13.2 17.5 19 28.1 38.8 Insulation class, motor B B B B B Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 Motor protection Integral Integral Integral Integral Integral MTP MTP MTP MTP MTP Sound pressure level at 3 m Weight Speed control kg Electronic Exhaust fan unit | Systemair Residential Ventilation Systems H Dimensions 50 * D A F B 47 E G C B * 27 C A D E F G H KVKE 125 EC 125 433 479 125 128.5 442 246 470 KVKE 160 EC 160 482 528 145.5 132.5 505 266 530 KVKE 200 EC 200 482 534 150.5 149 505 303 530 KVKE 250 EC 250 578 700 176 174 596 359 620 KVKE 315 EC 315 680 802 208.5 207.5 705.5 430 730 Add EC-Vent Controls to any EC fan to offer full Demand Control Ventilation See page 37 for details Ventilation accessories Electrical accessories Fast clamps Back draft damper Gravity louvre shutter Controller Control board FK p. 32 RSK p. 35 VK p. 34 MTP 10 p. 36 EC-Vent p. 37 Filter cassette Intake grid Intake grid FGR p. 35 IGK p. 33 IGC p. 34 Flexible silencer SCD p. 102 What does EC stand for? An EC-Motor = Electronically commutated motor. EC-technology is intelligent technology using integral electronic control to ensure that the motor always runs at optimal load. With ease of control, the speed can be varied to match the airflow demand and operate at much higher efficiencies than that of a standard AC motor - Therefore saving energy & money 25 26 | Exhaust fan unit Systemair Residential Ventilation Systems K - EC • EC-motors, high level of efficiency • 100% speed controllable • Speed regulator included • Low sound level • Integrated motor protection • Potentiometer included for ease of commissioning The K EC series is designed for installation in ducts. All the K-fans have minimum 25 mm long spigot connections. The fans have backward-curved blades and external rotor motors (EC). The FK mounting clamp facilitates easy installation and removal, and prevents the transfer of vibration to the duct. The fans are delivered with a pre-wired potentiometer(0-10V) that allows you to easily find the desired working point. The potentiometer is set between 6-10V from factory. This can easily be changed if the installation requires more performance. To protect the motor from overheating the fan has integral thermal contacts with electrical reset. The casing is manufactured from galvanised sheet steel with the seams folded to give the fan a close to air tight casing. Outdoor mounting and wet room applications are possible due to the fans air tight casing and the IP 55 rated terminal box with a IP 68 rated M20 cable gland. Performance SAP Appendix Q (*K160 EC Fan) 1 Exhaust Terminal Configeration Specific Fan Power (W/l/s) Energy Saving Trust Best Practise Performance compliant Kitchen +1 Additional wet room 0.24 Yes Kitchen +2 Additional wet room 0.27 Yes Kitchen +3 Additional wet room 0.30 Yes Kitchen +4 Additional wet room 0.36 Yes Kitchen +5 Additional wet room 0.43 Yes Kitchen +6 Additional wet room 0.57 Yes 2 3 4 5 1 2 3 4 5 Technical data K - EC 160 * 200 250 315 M 315 L Art no. 2580 2581 2583 2584 2585 V/50 Hz 230 230 230 230 230 Power W 74.4 78.6 119 166 340 Current A 0.63 0.63 0.92 1.14 2.08 Max air flow m3/hr 544 774 1033 1415 1732 R.p.m. min-1 Voltage/Frequency 3105 2468 2628 2113 2719 Max temp. of transported air °C 60 60 40 40 55 “ when speed controlled °C 60 60 40 40 55 dB(A) 47 51 46 50 57 3 3.8 3.5 7 7 Insulation class, motor B B B B B Enclosure class, motor IP 44 IP 44 IP 44 IP 44 IP 44 Motor protection Integral Integral Integral Integral V MTP MTP MTP MTP MTP Sound pressure level at 3 m Weight Speed control kg Electronic Exhaust fan unit | Systemair Residential Ventilation Systems Dimensions øB øA 88 D C (F) E 40 øA A B C D E (F) K160 EC Model 159 286 25 147 26 198 K200 EC 199 336 30 148 27 205 202 K250 EC 249 336 30.5 144.5 27 K315 M EC 314 408 32.5 160.5 27 220 K315 L EC 314 408 37.5 160.5 27 225 K 200 EC/AC EC-motors consume an average of 30% less energy than standard AC-motors In Europe alone, Ventilation fans consume about 197,000GWh Even a 12-15% increase in efficiency could reduce CO2 emissions by 19 million tons Its time to use Green Ventilation and do your bit for the environment Ventilation accessories Electrical accessories Fast clamps Back draft damper Gravity louvre shutter Controller Control board FK p. 32 RSK p. 35 VK p. 34 MTP 10 p. 36 EC-Vent p. 37 Filter cassette Intake grid Intake grid FGR p. 35 IGK p. 33 IGC p. 34 Flexible silencer SCD p. 102 27 28 | Exhaust fan unit TFSK - EC Systemair Residential Ventilation Systems • EC-motors, high level of efficiency • 100% speed controllable • Speed regulator included • Swing out motor / impeller for service • Integrated motor protection The TFSR EC and TFSK EC roof mounted fans are driven by EC motors and intended for use as extract fans in smaller premises such as self contained flats and apartments as well as storage areas, smaller work-rooms etc. The fans are delivered with a pre-wired potentiometer(0-10V) that allows you to easily find the desired working point. The isolation switch is integrated and there are several alternative roof curbs available as accessories. The tilting mechanism simplifies cleaning and maintenance. To protect the motor from motor from overheating, the fans have integrated thermal contact with automatic reset. TFSR EC comes with circular connection whilst the TFSK EC is provided with a square connection. The protection guard prevents un-intentional contact with the impeller. Performance Technical data TFSR / TFSK - EC 160 200 Art no. 1226/1223 1227/1224 Voltage/Frequency Power Current V/50 Hz 230 230 W 81.5 74.6 0.587 A 0.64 Max air flow m3/hr 580 778 R.p.m. min-1 3162 2501 Max temp. of transported air °C 45 45 “ when speed controlled °C 45 45 Sound pressure level at 3 m 43 43 4.2/4.6 5.4/6.2 Insulation class, motor B B Enclosure class, motor IP 44 IP 44 Motor protection Integral Integral MTP 10 MTP 10 Weight Speed control dB(A) kg Electronic Exhaust fan unit | Systemair Residential Ventilation Systems Dimensions øC A HC 36 E øD c/c F ø9(4x) TFSR A B øC øD HC TFSK A B øC E sq 160EC 147 172 334 380 205 160EC 147 172 334 421 330 200EC 150 187 364 439 250 200EC 150 187 364 421 330 TOB Profiled Roof Plate Ventilation accessories TOS Flat Roof Plate Electrical accessories Fast clamps Back draft damper Flexible silencer Controller Control board FK p. 32 RSK p. 35 SCD p. 102 MTP 10 p. 36 EC-Vent p. 37 B B A øC c/c F 29 30 | Accessories IGK Intake grid Exhaust fan unit FGR Filter cassette KVKE EC FK Fast clamp KVK CB/CBM Electrical heating battery FK Fast clamp SPI Iris damper LDC Silencer FK Fast clamp FK Fast clamp Sinus B Diffuser Sinus A Diffuser FK Fast clamps Mounting clips which facilitate the installation and removal of fans for service and cleaning. Made from galvanised sheet steel and fitted with an 8 mm neoprene lining which suppresses vibration and ensures a tight fit. The mounting clips are clamped together by two screws which allows for connecting ducts with a marginal difference in diameter. Hanging strap FK Art. no. øD mm 100 1607 100 125 1608 125 150 1609 150 160 1610 160 200 1611 200 250 1612 250 315 1613 315 Accessories | Exhaust fan unit SCD Flexible silencer The SCD silencer from Systemair is characterized by high flexibility and excellent sound insulation values. The internal duct consists of a closed, non-woven internal hose (washable) and an insulation layer made of glass wool with a thickness of 25 mm and sound reducing and thermal effective properties. The outer casing is made of glass-fibre reinforced, tear-resistant aluminium laminate. The silencer (1 m length) provides duct connections made of galvanized steel sheet on both sides for the connection directly to the duct system. One side is equipped with a connection sleeve and the other side with a connection fitting to guarantee connection flexibility. Technical data material (external) Aluminium material (internal) non-woven Matte Temperature range -30 bis +140 °C Working pressure max. 2000 Pa Air velocity max. 10 m/s Length 1,2 m Connection Sheet steel, galvanized Characteristics: Internal hose: non-woven mat Insulation: 25 mm glass wool Outer casing: glass-fibre reinforced aluminium laminate Fire classification Bs1 (EN13501-1) Noise suppression (dB), Non-woven Isoation 25 mm Type Art. no. D (mm) L (m) Fequenzy bands [Hz] 63 125 250 500 1000 2000 4000 8000 Tot (dB) SCD 80 2554 80 1,2 13,6 22,4 40,2 38,7 36,5 41,3 51,6 45,8 39 SCD 100 2555 100 1,2 15,9 22,9 31,1 38,6 36,4 40,6 50,1 35,9 39 SCD 125 2556 125 1,2 11,7 18,9 32,4 29,9 28,8 34,5 40,9 24,5 32 SCD 150 2557 150 1,2 12,2 10,9 29,7 30,1 29 38,3 34,6 20,4 32 SCD 160 2558 160 1,2 19,3 25,4 30,5 27,1 23,8 32,2 27,8 17,3 28 SCD 200 2560 200 1,2 10,7 12,1 28,7 22,8 22,8 30,6 19,4 11,9 26 SCD 250 2561 250 1,2 12,9 18,7 24,3 19,5 19,9 27,7 12,9 10,2 22 SCD 315 2562 315 1,2 16,6 23,2 18 15,2 16,5 19,6 10,1 8,5 17 (Test Report Nr. A1672-1, Peutzbv) IGC Intake grid Intake grid for inside or outside installation. Connection diameters ø100-315 mm, and is manufactured from die-cast aluminium and supplied with a wire mesh. øD = outside diameter ød = connection diameter ⌀d ⌀D IGC Art. no. ød øD 100 5581 100 125 125 5582 125 150 160 5583 160 185 200 5584 200 225 250 5585 250 275 315 5586 315 350 31 | Accessories Exhaust fan unit VK Gravity louvre shutter Louvre shutters for vertical mounting on a wall. The profiled vanes produce a strong upward force which reduces the air resistance. This means that the vanes opens fully at low air velocities as well. All the parts are manufactured in weather-resistant and shockproof nylon material (PVC containing special synthetic). The robust construction ensures that the vanes will not become deformed or loose. Above size 45, the vanes are fitted with a cast counterweight. Air velocity should not exceed 12 m/s. The louvre shutters are easy to install. Wall plugs and screws are included above size 15. F □C Pressure drop ØD A ØE B A Air velocity in duct m/s IGK VK Art. no. A B C D E F G 10 5636 142 15 103 96 5 46 3 12 5638 164 12 115 117 5 38 4 15 5605 178 20 130 152 4 50 5 20 5639 245 20 190 210 5 50 6 25 5640 299 25 235 260 5 70 5 30 5641 347 26 274 310 5 70 6 Intake grid Intake grid manufactured from galvanised sheet steel with wall flange and wire mesh. Connection sleeve with rubber seal. 265 B 60 A 253 Pressure drop 275 32 Wire mesh IGK Art.No. øA B 100 1630 100 37 125 1631 125 37 160 1632 160 37 200 1633 200 41 Accessories | Exhaust fan unit FGR Filter cassette for circular ducts The FGR filter cassette is fitted with a standard type G3 panel filter. The cassette housing is manufactured from galvanised sheet steel with rubber-sealed circular connections, toggle locks and disposable filters. Replacement PFR filters are sold in packs of five. The filter cassette is suitable for use as a supply-air filter in industrial workshops. The recommended final pressure drop is 170 Pa for the G3 filter. Free area for filter change G3 Filter mounting Filter cassette Art. no. Panel filter (incl. in FGR) Filter media FGR ø A B C D E FGR 100 1802 PFR 100-160 G3 100 100 123 199 205 201 190 FGR 125 1804 PFR 100-160 G3 125 125 123 199 205 201 190 FGR 150 1807 PFR 100-160 G3 150 150 123 199 205 201 190 FGR 160 1809 PFR 100-160 G3 160 160 123 199 205 201 190 FGR 200 1812 PFR 200 G3 200 200 123 199 302 297 280 FGR 250 1815 PFR 250 G3 250 250 123 239 302 297 280 FGR 315 1818 PFR 315 G3 315 315 123 239 350 345 330 RSK Back draft damper Back draft damper for circular ducts, manufactured from galvanised sheet steel. The two blades are spring-loaded, which means that the damper can also be mounted vertically. Pressure drop RSK Art. no. øA D B C 100 5597 100 80 24 33 125 5598 125 100 33 44 150 5599 150 100 34 43 160 5601 160 120 42 55 200 5602 200 140 55 62 250 5603 250 140 54 62 315 5604 315 140 50 65 33 34 | Accessories Exhaust fan unit MTP 10 Controller Potentiometer 10kΩ. Combined flush or surface mounting. For the manual control of speed and air flow of electrical fans with 0-10V output. The jetproof IP 54 enclosure is achieved with the included surface mounting case. (Flush-mounting without the surface mounting case, gives a splash proof IP 44 enclosure). NB! EC only. MTP 10 Art-no. 1 2 Us + - 3 4 5 32731 Voltage supply V DC 10 Control signal kΩ 0...10 Working range V 0...10 Contact Us = 0-10V + = 10V Supply Output signal - = GND Potentiometer 1 NO Switching capacity 4A/250V Enclosure class IP 44 Weight kg 0.2 The EC fans are delivered with a pre-wired potentiometer (0-10V) that allows you to easily find the desired working point. The potentiometer is set between 6-10V from factory. This can easily be changed if the installation requires more performance. The Potentiometer is fitted inside the fans terminal box REV Terminal Cable Description 1 Black 1 Tacho output, lsink max 10mA 2 Black 2 GND 3 Black 3 Control input 0-10 VDC/PWM 4 Black 4 Output 10 VDC max 1.1 mA ON-OFF service switch REV- Isolator mounted on a bracket, leads connected l max 16 A. -3POL/03 = 3-pole (closing/auxillary contact 1) lead 3x1.5 mm2 for 1 phase motor TK not lead out. EC-Vent / Accessories | Exhaust fan unit EC-Vent Demand controlled air volume Optimal degree of ventilation due to numerous sensors °C CO2 Summer/ Winter Time Temperature EC-Vent controls the degree of ventilation in buildings to meet different levels of occupancy as detected by sensors located within the areas to be ventilated. The result is an indoor climate that always matches building use and occupation. In opposite to Pressure Air Quality Manually Humidity Presence % other control systems, all sensors are included for the detection. 35 36 | EC-Vent / Accessories Exhaust fan unit EC-Vent: one control - numerous possibilities Name Article-No. EC-Vent remote control with integrated temperature and humidity sensor 3018 EC-Vent control box 3115 Room temperature sensor TG-R5/PT1000 5404 Fresh air temperature sensor TG-UH/PT1000 35203 Duct sensor TG-KH/PT1000 202705 Room humidity control /Hygrostat HR1 5150 Time switch 5165 Pressure sensor DSG 200 5169 Pressure sensor DSG 500 5170 Pressure sensor DSG 1000 9466 CO2 Transmitter (digital) CO2RT-R-D 6993 CO2 sensor CO2RT 13704 Presence sensor R24-P 6995 Wiring EC-Vent Room unit A= Power supply B=Sensor 24V/0..10V, e.g. pressure sensor, CO 2 sensor C= Temperature sensor PT1000 D= Digital sensor 24V, e.g. presence sensor E = Alarm relay F = EC fan G = Actuator 24V/0..10V, e.g. 3-way valve Control board H= Actuator 24V, e.g. spring-return damper motor I = Analog output 0..10V J =Modbus K= Connection EC-Vent RU EC-Vent / Accessories | Exhaust fan unit EC-Vent Room Unit Wall control unit for EC-Vent CB control device. Blue background illumination of the display, selection knob and 2 buttons. The EC-Vent control system consists of two units: one central unit CB to be placed near the fan and a display unit RU normally sited in a room easily accessible to the user. These units are connected to each other with a low voltage cable of a max. length of 30 m. The wall control unit is equipped with a built-in humidity and temperature sensor and 2 inputs for additional sensors. Control unit Art.No. 3115 - EC-Vent CB control box! Remote Control • Ready for connection to EC-Vent CB RU • 2 inputs for CO2, humidity, temperature, presence, pressure sensors etc. 1 input, digital / 0...10V / PT1000 and 1 input, digital / 0...10V Art-no. • Built-in humidity and temperature sensors Phase • User-friendly menu Voltage Ambient temp. 3018 V 24 DC = °C 0...50 • Absence mode and boost ventilation function Enclosure class IP 20 • 10 m connection wire incl. Weight kg 0.2 EC-Vent control board Control board • Built-in transformer (230V/24V) • Control of two fans humidity, temperature, etc.) can be combined to control the fan directly or as a complement to the weekly schedule and/or the manual control to boost the ventilation if needed. It can also be used to control a heater/ cooler or an extra fan via 0-10 V signal. The EC-Vent consists of two units, one central unit to be placed near the fan and a single display unit normally sited in a room easily accessible to the user. These units are connected to each other with a low voltage cable. The EC-Vent allows to connect up to 5 different sensors that simultaneously detect the actual ventilation requirements. In this way, the EC fan will be steplessly controlled to ventilate exactly as much as needed. The result is a good indoor air quality and the user avoids high electricity bills. The central unit for the EC-Vent can be operated standalone from the room unit. EC-Vent room unit RU (Art.No. 3018) is needed for configuration. • Heating/cooling control, 0..10V • 3 inputs, digital / 0...10V / PT1000 CB • 3 outputs, digital / 0...10V Art-no. • 1 output EC motor, PWM Voltage • 24V supply voltage for dampers and sensors etc. The EC Vent is more than a simple control for EC fans. Combined with EC fans, this tool simplifies demand-controlled ventilation making it easy to set up and operate. The unique feature of the EC-Vent is that it provides for a number of control options with up to five sensors (analog or digital). A single parameter such as temperature can be controlled at several different locations. Alternatively, various parameters, (CO2, 3115 V 230 Phase ~ 1 Frequency Hz 50/60 Current A 6 Recommended fuse A 10 Supply to sensor, 24V DC mA 150 Ambient temp. °C -20...50 Enclosure class IP 44 Weight kg 0.95 TG-R5/PT1000 TG-R5/PT1000 Room sensor For measuring room temperature. Art-no. Temp. range of adjustment Control signal Enclosure class WxHxD 5404 °C 0...50 PT1000 IP 30 mm 86x86x30 37 38 | EC-Vent / Accessories Exhaust fan unit TG-UH/PT1000 Outdoor sensor For measuring outdoor temperature. TG-UH/PT1000 Art-no. 35203 Temperature range °C -40...+60 Enclosure class WxHxD IP 65 mm 70x93x46 TG-KH/PT1000 Duct sensor Duct senor for measuring air temperature in ventilation ducts. TG-KH/PT1000 Art-no. 202705 Temperature range °C -30 – +70°C Time constant Insert length 16 s mm 60...205 Enclosure class IP 65 HR1 Room humidistat A humidistat for controlling exhaust air fans in response to the relative humidity. The humidistat uses human hair as the humidity sensor medium. The set-point can be anywhere between 10 and 95% RH. Base plate in black plastic and cover in white plastic. The HR1 is supplied with a sliding cover over the set-point dial, which can be locked. The humidistat should be mounted in a location with good air circulation and constant temperature and humidity. It should not be fitted on external walls, walls in direct sunlight, corners etc. The humidistat’s mounting holes make it suitable for fixing on to a terminal box with screws at 60 mm centres. The humidistat should be precision-calibrated after it has been mounted, and should be recalibrated regularly. Dust and other matter should be removed with a soft brush at regular intervals. T 120 Frame for wallmounting Timer Timer with 120-minute operating time. Supplied with flange for fitting into equipment housing. Casing for surface mounting is available as an extra. A switch for closing and breaking circuits. A link can be used to produce a change-over function. The timer makes a quiet ticking sound when connected. This timer is suitable for controlling the REU and RTRDU five step transformers. Contacts 1 and 3 close when the air humidity exceeds the preset value. HR1 Art-no. 5150 Setpoint %RH 10...95 Differential %RH 4% at 45 Switching capacity 250V/5A Max. operating temp. °C 40 Enclosure class IP 21 kg 0.1 Weight WxHxD mm 83x136x37 T 120 Voltage Frequency Max. current load V 230 Hz 50 A 10 (2) Connection time min 0...120 WxHxD mm 80x80x25 EC-Vent / Accessories | Exhaust fan unit DSG DSG 200/500/1000 Art-no. 5169/5170/9466 Voltage supply V Outp. 0-10 V, Imax Pressure sensor A membrane-type sensor for measuring the differential pressure in non-aggressive gases. The difference in pressure between the sensor’s plus (+) and minus (-) connections affects the membrane, which generates a voltage via a differential transformer. This voltage converts into a continuous DC voltage proportional to the membrane’s position. Cable length approx. 0.5m. CO2RT / CO2RT-R-D 2 Enclosure IP 65 Current A 0.012 Press. range 200 Pa 0...200 Press. range 500 Pa 0...500 Press. range 1000 Pa 0...1000 Brown Yellow Voltage supply 15...30V DC 24V AC ±15% Output White Pressure connection ø5 mm CO2-sensor for wall mounting CO2RT is a room sensor for measuring carbondioxide, CO2 concentration in indoor environments. Measuring range 0...2000ppm. Output signal 0...10 V for the full measuring range. CO2RT also has a temperature signal, 0...10 V DC for 0...50°C. Apart from the above mentioned temperature signal CO2RT also has a PT1000 temperature sensor with separate terminals CO2RT is intended for wall mounting. The display models (D) have an LCD-display showing both actual values by regularly alternating. CO2RT-R-D CO2RT 15V-30V DC/24V~± 15% mA CO2RT, CO2RT-R-D Art-no. Voltage 13704/6993 V 24 1 Supply voltage 24 V AC 1 Supply voltage 24 V AC Frequency Hz 50/60 2 System neutral 24 V AC 2 System neutral 24 V AC Power consumption W 3 3 Common 3 Output 0...10 V (humidity) Ambient temperature °C -5...+55 4 Normally open 4 Output 0...10 V (temperature) Re. humidity, non condens. % 90 5 Normally closed 5 Output 0...10 V (CO2) 8 6 Signal neutral 7 Output, PT1000-sensor Output, PT1000-sensor IR24-P Working range ppm Enclosure class IP 30 Weight kg 0.1 Dimension mm 0...2000 85x100x30 Presence detector A detector that gives a signal when someone is present in the room under supervision. The detector has a pulse detecting function that minimizes the risk for false alarm. Settable output on/off delay. Intended for wall or ceiling mounting. IR24-P is a presence detector designed for automatic ventilation control of HVAC systems. IR24-P Art-no. Voltage supply Ambient temperature Max. ambient humidity 6559 V °C 24 V AC/DC -20...+50 %RH 95 Enclosure class IP 40 Circuit-breaking relay A NC/NO Switching capacity Dimensions 24V DC/0,2A mm 112x66x45 39 40 | Exhaust fan unit Systemair Residential Ventilation Systems BF These Axial domestic fans are designed for either wall. ceiling or window* mounting (*kit required) and are ideal for toilets. bathrooms. utility Rooms & kitchens to comply with building regulations on Ventilation. The range includes 100mm. 120mm & 150mm sizes with options for built in sensors to suit all your needs. The units are all manufactured using high ABS thermoplastics for strength and durability. aesthetics and easy cleaning. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee. Fan Options Technical Data Ref Code Product Type BF *** S Axial Fan. Standard model for remote switching (Light switch etc) BF *** T Axial Fan. Timer model incorporating adjustable timer (1-20 mins) BF *** TH Axial Fan. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins) BVK*** Wall Fitting Kit - (External grille. white + wall sleeve) EGK*** Window Fitting Kit EFS-PIR Passive Infra Red Sensor with run on timer BF100 BF120 23 l/s 36 l/s 64 l/s 85m3/hr 130m3/hr 230m3/hr Spigot Size 100mm (4”) 120mm (5”) 150mm (6”) dBA @ 3m 36 36 35 230-1-50 230-1-50 230-1-50 0.12 0.15 0.15 Maximum Airflow l/s m3/hr Voltage Amps BF150 *** Fan Size 100. 120 or 150 Dimensions A B C 100 mm 163 98 67 120 mm 182 118 112 150 mm 203 150 72 IF The Systemair range of domestic in-line fans are designed for duct mounting and are ideal for toilets. bathrooms. shower rooms. utility rooms & kitchens to comply with building regulations on ventilation. The range includes 100mm. 120mm & 150mm sizes. The units are all manufactured using high ABS thermoplastics for strength and durability. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee. Technical Data IF 100 IF 120 23 l/s 36 l/s 64 l/s 85m3/hr 130m3/hr 230m3/hr Spigot Size 100mm (4”) 120mm (5”) 150mm (6”) dBA @ 3m 32 32 31 Voltage 230-1-50 230-1-50 230-1-50 Amps 0.12 0.15 0.15 Power W 20 25 25 Maximum Airflow l/s m3/hr IF150 Dimension IF 100 IF 120 IF 150 øA 100 118 150 B 90 99 110 Exhaust fan unit | Systemair Residential Ventilation Systems EAF LV/ ECF LV The Systemair range of Low-voltage domestic fans are designed for either wall or ceiling mounting and are ideal for shower rooms & bathrooms to comply with building regulations on Ventilation. The range includes 100mm (4”) axial & centrifugal fans with a remote Safety Extra Low Voltage transformer offering integral control options to suit all your needs. The units are all manufactured using high ABS thermoplastics for strength and durability. aesthetics and easy cleaning. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee. Technical Data EAF 100LV ECF 100LV l/s 23l/s 31l/s m3/hr 85m3/hr 110m3/hr Spigot Size 100 mm (4”) 100 mm (4”) dBA @ 3m 36 39 Voltage 230-1-50 Input Amps 12 Volt A.C - SELV Power W 20 Maximum Airflow 20 Ref Code Product Type EAF 100 LV Low Voltage Axial Fan 100mm to be used with ET Transformer ECF 100 LV Low Voltage Centrifugal Fan 100mm to be used with ET Transformer A 82 mm B 145 mm C 65 mm Transformer Part Ref ET12S Low Voltage Transformer. Standard model for remote switching (Light switch etc) ET12H Low Voltage Transformer. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins) ET12T Low Voltage Transformer. Run on timer (1 - 20 mins) ET12P Low Voltage Transformer. Pullcord 163 67 41 42 | Exhaust fan unit Systemair Residential Ventilation Systems CF The Systemair range of domestic centrifugal fans are designed for either wall or ceiling mounting and are ideal for toilets & bathrooms to comply with building regulations on Ventilation. The fan has a 100mm 4” spigot with an integral back draught shutter with options of built in sensors to suit all your needs. The units are all manufactured using high ABS thermoplastics for strength and durability, aesthetics and easy cleaning. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee. Ref Code Product Type CF 100 S Centrifugal Fan. Standard model for remote switching (Light switch etc) CF 100 P Centrifugal Fan. as above but supplied with pullcord switch CF 100 T Centrifugal Fan. Timer model incorporating adjustable timer (1-20 mins) CF 100 TH Centrifugal Fan. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins) BVK100 Wall Fitting Kit - (External grille. white + wall sleeve) EFS-PIR Passive Infra Red Sensor with run on timer Technical Data CF Maximum Airflow l/s m3/hr 25l/s Dimensions CF100 90m3/hr Spigot Size 100mm (4”) A B C D E Weight/kg dBA @ 3m 37 163 98 Dia 65 90 163 1.1 kg Voltage 230-1-50 Amps 0.2 Power W 25 CBF Technical Data CBF100 Maximum Airflow l/s m3/hr Spigot Size dBA @3m Voltage Amps Power W Ref Code Product Type CBF 100 S Centrifugal Fan. Standard model for remote switching (Light switch etc) CBF 100 P Centrifugal Fan. as above but supplied with pullcord switch CBF 100 T Centrifugal Fan. Timer model incorporating adjustable timer (1-20 mins) CBF 100 TH Centrifugal Fan. Adjustable Humidity control between 40% & 95% RH + Run on timer (1 - 20 mins) BVK100 Wall Fitting Kit - (External grille. white + wall sleeve) EFS-PIR Passive Infra Red Sensor with run on timer 31 l/s 110 m3/hr 100 mm (4”) 39 230-1-50 0.27 45 CBF 100L Exhaust fan unit | Systemair Residential Ventilation Systems RVF - External Wall Fan • Speed-controllable • For mounting on external walls • Useful where internal space is limited • Powerful extract performance with low noise The RVF models are exhaust-air fans for installation on external walls. The unit consists of an impeller with backward-curved blades and a casing in galvanised sheet steel with a white powder-paint coating. All ambient noise created by the fan is kept outside the building if it is installed on an external wall. Technical Data RVF 100M Maximum Airflow RVF 100XL l/s 50l/s 80l/s m3/hr 200m3/hr 280m3/hr Spigot Size 100 mm (4”) 100 mm (4”) dBA @ 10m 26 37 Voltage 230-1-50 Input Amps 0.16 0.26 Power W 28 60 Speed rpm 2489 2433 Speed Controller REE 1 REE 1 Weight kg 4 5 Max temp of transported air (C) 70 deg C 70 deg C 43 | Multi Extract fan unit Systemair Residential Ventilation Systems MVS - DC The Centralised Ducting System (MVS) provides continuous mechanical ventilation throughout the entire house from a single extraction unit and can be used in up to three individual rooms. Made from strong ABS plastic it is very lightweight. making it easy to install in a loft or ceiling void. The fan unit is supplied with three extraction inlets. all 125mm which discharge from one 125mm extract duct through either a wall or roof terminal. Control options The MVS-10 has 14 speed steps, and a standard is set to speed steps 1, 4 and 8 (Low, Normal and Boost respectively). The speed settings for Low, Normal and Boost speeds can quickly be altered by changing the dipswitches under the top cover. The MVS10 can be controlled by a 3 speed switch or a motor less cooker hood, (F251). The MVS-10R is controlled by the wireless remote speed controller and is also fitted with an induct humidity sensor to automatically increase the speed of the unit when rapid increases in humidity levels occur. The MVS-10 can also be controlled by an external 0-10V signal (not applicable to the MVS-10R). TECHNICAL DATA MVS-10 Technical Data Model Speed Airflow Voltage Pressure Step m3/hr V Pa MVS-10DC Motor Data FLC W 400 Pa 1 LOW 85 230-1-50 10 0.06 6 21 Output High 24.4 W 3 MIDDLE 127 230-1-50 21 0.07 8 34 Medium 9.9 W 6 MIDDLE 200 230-1-50 50 0.12 17 48 Low 5.1 W 7 HIGH 225 230-1-50 65 0.14 20 49 Max amperage 0.18 amps 9 HIGH 270 230-1-50 85 0.21 31 52 Voltage 230-1-50 11 HIGH 320 230-1-50 130 0.40 56 54 Weight 3.5kg 14 HIGH 375 230-1-50 175 0.60 81 58 Connection diagram for the MVS-10-type EC fans with 3 speeds 500 450 14 400 13 12 350 c = graph number X = power consumption (Watt) 65 57 11 300 48 78 Pascal 250 40 10 68 59 200 30 9 48 7 27 9 3 0 0 50 6 20 17 12 8 6 6 31 26 15 11 9 7 6 6 40 17 8 2 56 24 12 5 1 73 66 14 4 50 35 20 6 100 81 24 8 150 7 8 100 10 m3 / h 150 200 250 300 350 400 450 500 Orcon bv Storkstraat 23, 3905 KX Veenendaal, Netherlands P.o. box 416, 3900 AK Veenendaal, Netherlands Tel. +31 (0)318 54 47 00, Fax +31 (0)318 54 47 06 E-mail info@orcon.nl, www.orcon.nl V E N T I L AT I O N S Y S T E M S dBA @ 1m Static Pa @ 225m3/hr Measured on the 13 of February 2007 in the anechoic chamber of EBM Papst 44 F O R D O M E S T I C A N D C O M M E R C I A L A P P L I C AT I O N S Commercial fan units | Systemair Residential Ventilation Systems ES The Systemair range of commercial fans are ideal for Offices, Student Accomodations & cleaners cupboards to comply with building regulations on Ventilation. The range includes 6”. 9” & 12” models all fully speed controllable. with the 9 & 12” models being reversible for supply & extract air. The fans are complete with thermo-activated shutters to prevent draughts and save on costs. Different coloured grilles are available in white. terracotta & brown. standard model is pale grey. The units are all manufactured using high ABS thermoplastics for strength and durability. aesthetics and easy cleaning. The Panel model is designed for refurbishment projects as they will fit most leading commercial wall liners. All products are BEAB approved and carry the CE marking and come complete with a 2 year guarantee. Fan Ref Size 6 Size 9 Size 12 Controls. Sensors & Ancillaries Maximum Airflow l/s (m3/hr) 77 (278) 185 (668) 281 (1021) EAC6 Variable speed control (6” only) EAC9/12 Variable speed control & reversible Sound Power Level dBA@3m 40 53 60 EFS-PIR Passive infra red sensor with run on timer Voltage 230-1-50 230-1-50 230-1-50 EFS-HS Humidistat Amps 0.24 0.4 0.6 EFS-7DAY 7 day analogue timer Power W 45 80 120 EFS-ROT Run on timer 1-20 mins Controller EAC6 EAC9/12 EAC9/12 EFS-ISO Isolator Switch 3Pole Performance Graph Wall Fan Dimensions Fan Ref A B C D E Hole Dia ES6W (Wall) 310 310 160-290 278 288 - ES9W (Wall) 390 390 160-290 361 366 - ES12W (Wall) 470 470 160-290 440 447 - ES6P (Panel) 310 310 110 - - - ES9P (Panel) 390 390 138 - - - ES12P (Panel) 470 470 154 - - - ES6G (Window) 205 105 25 - - 184 ES9G (Window) 286 125 25 - - 260 ES12G (Window) 362 145 25 - - 320 Panel Fan Window Fan 45 46 | Heat Recovery unit Systemair Residential Ventilation Systems High efficiency heat recovery systems SaveVent Comfort C Low Energy Counterflow Heat Recovery Units SaveVent Comfort R Low Energy Thermal Wheel rotational heat exchanger Overview SaveVent Comfort applications SaveVent Comfort C C R Property Type Single family house / Single flat Muliple Dwellings Single family house / single flat System Heat Recovery Heat Recovery Heat Recovery Location Plant Room / Store / Cupboard Plant Room Plant Room / Store / Cupboard Ventilation Range SAVE VTC SAVE VTC*, Topvex SC* VR Extract valves in bathroom, toilet and kitchen; products: valves in bathroom, toilet and kitchen; products: valves in bathroom, toilet and kitchen; products: valves Supply valves In Bedrooms & living room In Bedrooms & living room In Bedrooms & living room Heat Recovery unit | Systemair Residential Ventilation Systems General description • The unit is completely self-controlled and is easy to run by the user • Heat recovery pre-heats supply air • Fine filters provide clean and dust-free supply air • A rotary heat exchanger recovers humidity during winter time • No temperature fluctuations and cold zones in rooms - even at cold outside temperature Systemair duct systems Multiple options available Systemair Air Distribution Products Just your style - Wall or Ceiling mounted Function Exhausted air from kitchens and bathrooms is ducted via the heat recovery unit to the outside. The unit draws fresh air through a seperate duct system. The heat of the exhaust air is transferred up to 88 % by a heat exchanger to the supply air and returned to living and bedrooms. Within the unit the air is filtered, warmed and dehumidified. Supply & Exhaust ductwork is installed to meet the requirements and restrictions of the building. Building Regulations -Part F Ventilation 2010 Table 5.1a Extract Ventilation rates Room Intermittent Extract Minimum Rate Continuous Extract Minimum High Rate Kitchen 30l/s adjacent to hob; or 60 60l/s elsewhere 13l/s Utility room 30l/s 8l/s Bathroom 15l/s 8l/s Sanitary accommodation 6l/s 6l/s Minimum Low Rate Total extract rate should be at least the whole dwelling ventilation rate given in Table 5.1b Table 5.1b Whole dwelling Ventilation rates 1 Whole dwelling ventilation rate a,b (l/s) 13 Number of bedrooms in dwelling 2 3 4 17 21 25 5 29 Notes: a. In addition, the minimum ventilation rate should be not less than 0.3l/s per m2 of internal floor area. (This includes all floors, e.g. for a two-storey building add the ground and first floor areas) b. This is based on two occupants in the main bedroom and a single occupant in all other bedrooms. This should be used as the default value. If a greater level of occupancy is expected add 4l/s per occupant. 47 48 | Heat Recovery unit Systemair Residential Ventilation Systems Advantages & Dis-advantages for different Dwelling types Advantages for a single-family house • High heat recovery, thermal comfort • Less ventilation heat losses • Humidity regain during winter time with one rotor • Pre-heating supply air • Higher energy saving potential Disadvantages for a single-family house • Complex duct system • Higher investment costs Advantages for an apartment building • High energy saving potential and less heating is required • High heat recovery Disadvantages for an apartment building • Complex duct system • Higher investment costs • Fire safety and sound protection requirements • Central units: „Heat theft“ Apartment building, decentrally, example for an apartment Conclusion: A ventilation unit with heat recovery provides a healthy, comfortable indoor enviroment with filtered supply air to the dwelling. Furthermore, the energy saving potential meets the future requirements. The decision for a unit with heat recovery allows combining comfort and energy savings. Counterflow heat exchanger vs. rotary heat exchanger: a rotary heat exchanger is the best choice for single-family houses or single residential units. It is more effective and creates a better indoor climate plus thers is no requirement for a condensate drain to overflow. These rotary wheel units also allow for automatic summer by-pass during warmer months. To supply more than one residential unit, a counterflow heat exchanger is the right choice. The required energy for frost protection reduces the efficiency of this exchanger. Heat Recovery unit | Systemair Residential Ventilation Systems Comparison rotating heat and plate heat exchanger Rotary heat exchangers: With these fans, heat as well as humidity can be exchanged. Application for singlefamily houses or residential units with efficiencies up to 85 %. Heat exchanging The wheel structure (similar to corrugated board) of the exchanger and continuous rotation between hot and cold air flows heats the exhaust air wheel which transfers this heat to the cold supply air in winter time. This effect can be used vice versa in summer time by transferring heat of the outside air to the colder exhaust air. This provides a cooling effect in summer and also leads back the cooling energy of the air conditioning. Humidity transfer with a condensation rotor The thermal wheel heat exchanger consists of pure aluminium which transfers humidity exactly when condensate appears on the exhaust air side and is absorbed by the outside air. High temperature differences can reach humidity return values up to 60 %. With our rotors, humidity is transferred when needed in winter time. This minimizes dry air. rotation of the storage mass. Constructive modifications prevent this for units which are /DE marked (transmission 0.1 %). Rinse chamber Some outside air flow is led on the exhaust air side to produce a rinsing effect. This reduces the transmission of exhaust air to a minimum by carryover. For correct operation of the rinse chamber, a pressure gradient of min. 200 Pa on supply and exhaust air is necessary. Frost protection A condensate drain is not required in residential construction. Furthermore, the rotor does not freeze because of the transmission of condensate down to -30 °C by a little exhaust air surplus. A frost protection for heat exchangers is not needed. Counterflow heat exchanger Counterflow heat exchangers are used to transfer heat and can reach an efficiency of more than 90 %. Heat exchanging Counterflow heat exchangers lead air flows through parallel plates arranged in a row. On the opposite side supply and exhaust air alternates. Warm air flow transfers energy via the plate to the cold air flow. Humidity transfer is not possible In winter time, condensate has to be drained into a waste water pipe. The drain should always have either a water trap or running trap to prevent stale odours from coming back up from the drain system. Separated Air Streams Supply and exhaust air are totally separated from each other to keep the supply air clean. Frost protection The higher the efficiency of an exchanger, the more condensate drops out at high temperature differences. The efficiency also influences the temperature when frost protection is necessary for the exchanger. This concerns outside temperatures when condensate starts freezing. For high quality counter cross-flow heat exchangers with an efficiency of 90 %, this can already begin at -3 °C. In contrast, simple cross-flow heat exchangers with an efficiency of app. 55 %, this does not start until app. -14 °C. The amount of energy necessary for frost protection is correspondingly different. To ensure frost protection and to avoid pulling out energy from the exchanger, outside air can be pre-heated, the supply air can be set back or or the outside air can be bypassed at the heat exchanger via a bypass flap. The missing heat transfer by setting back the supply air fan or during bypass of the supply air has then to be replaced by the heating system. 49 50 | Heat Recovery unit Systemair Residential Ventilation Systems Overview Residential Heat Recovery Units VR 250 ECH/B VTR 150 VTR 200B VTC Low E Application Flats / Apartments Individual Homes Multiple Housing / Student Accomodation Larger Family Homes SAP Appendix Q Approved design until living space 90 100 140 100 m³/h 130 236 270 155 dB(A) 47 43 41 47 % 85 85 85 86 supply air filter - F7 G3 F7 G2 extract air filter - G3 G3 G3 G2 V/50Hz 230 230 230 230 max. air volume at 120 Pa max. sound level at 1m distance efficiency heat recovery voltage/frequecy m² max. power fans, each W 59 86 84 26.5 electr. Heater W 500 500 or 1000 500 or 1000 N/A fuse A 10 10 10 10 protection class IP 24 24 24 24 weight kg 38 54 46 26 duct connections mm 125 125 125 125 width mm 1070 600 598 598 height mm 265 774 750 579 depth mm 513 467 428 280 Isolation of casing mm 20 30 30 10 condensate connection (2x) no no no 2 no page 52 54 56 58 Heat Recovery unit | Systemair Residential Ventilation Systems VR 300 ECV/B VR 400 DCV/B VR 700 DCV SAVE VSR 300 SAVE VSR 500 SAVE VTC 300 SAVE VTC 700 Available with cross flow heat exchangers - VX models 130 220 350 240 400 300 / 250 600 / 560 210 320 530 336 593 410 / 340 860 / 830 46 47 51 50 50 45 53 85 85 80 85 80 80 85 F7 F7 F7 F7 F7 G4 / F7 G4 / F7 G3 G3 G3 G3 G3 G4 / F7 G4 / F7 230 230 230 230 230 230 230 100 115 240 83 169 85 168 500 or 1000 1670 1670 1670 1670 1700 1700 10 10 16 10 13 10 13 24 24 24 24 24 24 24 41 56 73 61 72 72 150 125 160 (Bypass 125) 200 160 200 160 250 598 796 918 1120 1120 762 1170 630 800 800 582 632 802 1214 326 406 517 461 551 616 860 20 30 30 30 30 30 30 no no no no no 1/2” 1/2” 60 62 64 66 68 74 76 51 52 | Heat Recovery unit Systemair Residential Ventilation Systems VR 250 ECH/B • 85 % heat recovery efficiency • Designed air flow up to about 100 m³/h at 75 Pa (for app. 80 m² living space) • Humidity recovery: no condensate connection, no frost protection • For ceiling and wall mounting • Remote control CE necessary The housing is insulated with 20 mm PU foam. Top and bottom section can be removed for maintenance. Connection to kitchen hood with an extra connection (DN125) possible. Exhaust air from the hood is bypassed at the rotary heat exchanger, directly to the exhaust air fan. When the hood starts, both fans run at maximum speed. As a result of a considerably lower pressure loss in the kitchen hood duct, the exhaust air fan boosts more air than the supply air fan whereas app. 80 % of exhaust air is led through the hood. Make sure that enough outside air is available during kitchen hood operation. Optional connection to kitchen hood (type 251-10/B - page 81). Art-no. 12536 Supply VR 250ECH/B Surrounding Mid-frequency band, Hz LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k Supply 67 57 60 60 59 60 57 51 41 Extract 56 42 42 49 53 49 33 24 20 Surrounding 47 31 41 36 41 42 36 33 29 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. Exhaust VR 250 ECH/B Voltage/Frequency VR 250ECH/B Power consumption per fan at operation point SFP V/50 Hz W 230 ca. 30 100 m³/h at 80 Pa kW/m³/s 2,11 Wh/m³ 0,6 Fuse A 10 Electr. re-heater W 500 Filter, fresh air F 7, bag filter Filter, extract air G 3, bag filter Weight / incl. packaging kg 45 Dimension (L x B x H) mm 1071 x 513 x 265 Connection DN 125 53 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme F7 VR EF SF BP ETS EH G3 SS OT ET EHS Filter fresh air Rotating heat recovery unit Extract fan Supply fan Bypass duct Extract air temp. sensor Electric heater Filter extract air Supply air temp. sensor Overheating thermostat Emergency thermostat Temp. sensor as rotating controller Dimension 196 93 783 40 3 Ø125 195 540 1 2 1071 4 A Duct connections, Ø125 mm: 94 70 290 263 131 263 513 H 124 131 147 40 71 77 5 H 64 513 B G C D 1 3 1 2 3 4 5 Fresh air/outside air Exhaust air Supply air Extract air Cooker hood (Bypass) A B C D E F G H Filter, fresh air-/outside air F7 Rotating heat recovery unit Supply air fan Reheater battery, electrical heating element, 500 W Filter, extract G3 Extract air fan Control circuit board and rotor motor for heat exchanger Anti-vibration ceiling mounting bracket 4 2 5 F E Accessories Control panel Cable Timer Timer Cooker Hood Frame for wallmounting CE p. 80 CEC p. 80 Timer p. 80 TFV p. 80 Wall bracket p. 83 RCE p. 80 54 | Heat Recovery unit Systemair Residential Ventilation Systems VTR 150/K • High efficiency rotary heat exchanger • Energy efficient Radical-fans, with modern EC-technology • Separate settings of supply and extract air flow • Start-up wizard for easy commissioning • Modern design with integrated cooker hood – VTR 150/K • Automatic change to summer operation (without heat recovery) • Demand control regulation • Low sound level An intergral cooker hood is fitted as standard to this unit Supply SF SAVE VTR 150/K has an integrated cooker hood and should be placed above the hob. The unit has been adapted to suit different kitchen environments, with a modern design. The customer has the choice of choosing between a white or stainless steel front. The unit is controlled by a separate control panel. SAVE VTR 150/K is adapted for ventilation of smaller houses and apartments with an area of 100 m² . The extract air from the cooker hood is by-passed, hence the heat exchanger is not being exposed to extract air from the kitchen. The units are insulated against condensation. P2 SF P2 ,5 SF P1 ,0 SF ,5 VTR150/K 500 W (S/S / White) 1000 W (S/S / White) L handed S/S or White 18991 / 14991 18881 / 14881 R handed S/S or White 18990 / 14990 18880 / 14880 P1 Extract ,2 VTR 150/K Voltage/Frequency Power consumption per fan at operation point SFP V/50 Hz W 230 ca. 15 100 m³/h at 80 Pa kW/m³/s 1.1 Wh/m³ 0.3 Fuse A 10 Electr. re-heater W 500 or 1000 Filter, fresh air G 3, bag filter Filter, extract air G 3, bag filter Weight / incl. packaging kg 54 Dimension (L x B x H) mm 600 x 467 x 774 Connection DN 125 Heat Recovery unit | Systemair Residential Ventilation Systems Dimensions 470**) 348 598*) 720 774 7 133 Accessories Potentiometer MTP 20/20K p. 81 293 99 237 102 191 84 596 55 56 | Heat Recovery unit Systemair Residential Ventilation Systems VTR 200/B • High efficiency rotary heat exchanger • Energy efficient Radical-fans, with modern EC-technology • Separate settings of supply and extract air flow • Start-up wizard for easy commissioning • Modern design with integrated cooker hood – VTR 150/K • Automatic change to summer operation (without heat recovery) • Demand control regulation • Low sound level SAVE VTR 200/B is a white painted model with an integrated control panel in the front door. The option for connecting one or more external control panels is also available. Connection to an external cooker hood is available on the top of the unit. This makes the unit well suited for apartment buildings where the extract air from the cooker hood is challenging. SAVE VTR200/B is adapted for ventilation of smaller houses and apartments with an area of 140 m². The extract air from the cooker hood is by-passed, hence the heat exchanger is not being exposed to extract air from the kitchen. The units are insulated against condensation. Supply SFP 2,5 VTR 200/B Art-no. SFP 2,0 SFP SF 500 W 1000 W L handed 14993 14882 R handed 14992 14882 1,5 P1 Extract ,2 VTR 200/B Voltage/Frequency Power consumption per fan at operation point SFP V/50 Hz W 230 ca. 18 100 m³/h at 80 Pa kW/m³/s 1.27 Wh/m³ 0.35 Fuse A 10 Electr. re-heater W 500 or 1000 Filter, fresh air F 7, bag filter Filter, extract air G 3, bag filter Weight / incl. packaging kg 47 Dimension (L x B x H) mm 598 x 428 x 750 Connection DN 125 Heat Recovery unit | Systemair Residential Ventilation Systems Dimensions 598 750 799 428 366 598 207 340 208 627 78 160 198 285 428 124 191 77 982 29 * 1180 Connection dim.: Ø125 * Extract air from cooker hood 416 598 Accessories Control panel Cable Cooker Hood CD p. 81 CEC p. 80 Wall bracket p. 83 57 58 | Heat Recovery unit Systemair Residential Ventilation Systems VTC Low E • High efficiency counterflow heat recovery unit up to 86 % • Energy efficient fan motors with modern EC technology • Operation from cookerhood or wall mounted speed controller • Integral summer by-pass • Integral Humidi-sensor to boost unit on rise in humidity from wet rooms. • Unit available with or without cookerhood. • Design to accept Kitchen face panels to blend in. • SAP Appendix Q Approved. Art-no. 52083 TSL-1/EC Cookerhood The VTC Low E Heat Recovery Ventilation unit is double skinned for quiet operation and prevent condensation forming. The unit is equipped with single inlet centrifugal fans on inlet and extract, filter on fresh air and extract, Counterflow heat exchanger, condensate drains and inspection door in front. The fan speed is controlled in 2 or 3 steps either from the cookerhood or separate controller mounted on the wall. Controlling the system from the Cookerhood The unit is designed for connection to and for operation from a cookerhood. The cookerhood is provided with special plugs for direct connection if the cookerhood is installed under the unit. Controlling the system from separate controller The unit can be installed over the cooker, on the wall or in the roof space. Fresh air is supplied to living room and bedrooms and stale air is extracted via the cookerhood or louvre in the kitchen, utility room, bathroom and WC. Energy efficient fans with EC motors will reduce energy consumption for transportation of ventilation air by apx. 50 % compared to traditional AC motors. Modern technology gives low SFP factor (Specific Fan Power). G2 filters are delivered as standard, with the option for G3 or G4 SAP Appendix Q Approved Exhaust Terminal Configeration Specific Fan Power (W/l/s) Heat Exchanger Efficiency (%) Energy Saving Trust Best Practise Performance compliant Kitchen +1 Additional wet room 0.76 86 Yes Kitchen +2 Additional wet room 0.73 85 Yes Kitchen +3 Additional wet room 0.83 85 Yes Kitchen +4 Additional wet room 1.02 84 No Kitchen +5 Additional wet room 1.04 83 No The unit can be controlled from a wall mounted 2 or 3 step speed regulator Heat Recovery unit | Systemair Residential Ventilation Systems Supply 59 Extract ,5 P2 SF SFP 2,0 SFP 1,5 SF P1 ,2 [l/s] Dimension η SFP = Specific Fan Power (kW/m3/s) The SFP value stated applies to the complete unit. TSL-1EC pg 83 MTP Controller 60 | Heat Recovery unit Systemair Residential Ventilation Systems VR 300 ECV/B • 81 % heat recovery efficiency • Designed air flow up to about 210 m³/h at 120 Pa (for app. 130 m² living space) • Humidity recovery: no condensate connection, no frost protection • Free selectable air volume in 3 steps • For wall mounting • Remote control CD necessary A cooker hood can be installed directly under the unit page 81. Art-no. 500 W 1000 W 12519 12520 Supply VR 300ECV/B The VR 300 ECV/B is a compact unit for ventilation of homes and primarily developed for wall mounted installation but can be installed horizontally e.g. in a false ceiling. The unit is double skinned, fully insulated, equipped with centrifugal fans for supply/extract air, rotating heat exchanger, filters and thermostat operated re-heater battery. VR 300 ECV/B is equipped with large inspection hatches on both sides and is by that means reversible for optimal and simple duct connections. The cooker hood can be connected via duct on the top of the unit if it is placed separate from the kitchen. As an alternative, a cooker hood can be installed directly under the unit. The extract air from the cooker hood is drawn via an integrated bypass duct directly to the extract fan bypassing the exchanger block. The airflow is set from a cooker hood or a separate control switch. Surrounding Mid-frequency band, Hz LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k Extract 54 42 51 43 47 48 37 26 22 Supply 70 59 61 61 63 65 60 52 43 Surrounding 43 24 37 38 36 33 29 23 15 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. Extract VR 300ECV/B VR 300 ECV/B Voltage/Frequency Power consumption per fan at operation point SFP V/50 Hz W 230 ca. 40 140 m³/h at 80 Pa kW/m³/s 1,89 Wh/m³ 0,5 Input power, fan motor(s) W 2x100 Input power, electrcal heating battery W 1000 Recommended fuse A 10 Filter, supply air F 7, bag filter Filter, extract air G 3, bag filter kg 40,6 Weight Dimension (L x B x H) mm 598 x 326 x 630 Connections DN 125 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme SS SF SFL EFL BD ET OT ELH SF Supply fan EF Extract fan SFL Supply filter EFL Extract filter SS Supply air temp. sensor HE Heat exchanger ELH Electric heater OT Overheating thermostat ET Emergency thermostat BD Bypass duct EF HE BD Dimensions F C D A E B E D A C B Duct connection ø125mm A Supply air B Exhaust air C Outdoor air D Extract air E Cooker hood (Alt. connection) F Cooker hood Accessories Potentiometer MTP 20/20K p. 81 Cooker Hood Wall bracket p. 83 SAP Appendix Q Approved Exhaust Terminal Configeration Specific Fan Power (W/l/s) Heat Exchanger Efficiency (%) Kitchen +1 Additional wet room 1.73 77 Kitchen +2 Additional wet room 1.69 80 Kitchen +3 Additional wet room 1.69 80 Kitchen +4 Additional wet room 1.66 81 61 62 | Heat Recovery unit Systemair Residential Ventilation Systems VR 400 DCV/B • High efficiency heat recovery unit without need for defrosting • Energy efficient fan motors with modern EC technology. • Operation from user friendly control panel, type CD with LCD-display, included • Separate setting of supply and extract airflow. • Constant airflow and balance between extract and supply air. • Changes automatically to summer operation with no heat recovery. • Flexible installation. No need for condensation drain. • Suited for demand control. • Modbus communication via RS-485 Art-no. 12314 Supply VR 400DCV/B DCV(/B) units are designed for installation on wall, in laundry rooms, utility rooms or similar. With the white painted door and side panels the unit can easily be installed to blend in with the surroundings. Large inspection doors simplifies inspection and service. The VR 400 DCV/B has a by-pass function which allows the unit to be connected to a kitchen hood. The polluted air from the hood is led directly to the extract fan without coming in contact with the rotating heat exchanger. Surrounding Mid-frequency band, Hz LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k Extract 56 46 48 51 52 45 39 28 20 Supply 66 52 55 56 58 62 60 52 46 Surrounding 47 29 35 37 41 41 41 35 30 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. Extract VR 400 DCV/B VR 400DCV/B Voltage/Frequency Power consumption per fan at operation point SFP V/50 Hz W 230 ca. 65 260 m³/h at 80 Pa kW/m³/s 1,82 Wh/m³ 0,5 Recommended fuse A 10 Input power, fan motor(s) W 2x114 Input power, electr. heating battery W 1670 Filter, supply air F 7, bag filter Filter, extract air G 3, bag filter Weight / incl. packaging kg 56,4 Dimension (L x B x H) mm 796 x 406 x 800 Connection DN 160/125 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme F7 VR EF G3 ETS SF EH SS OT ET EHS FS Dimensions Filter fresh air Rotating heat recovery unit Extract fan Filter extract air Extract air temp. sensor Supply fan Electric heater Supply air temp. sensor Overheating thermostat Emergency thermostat Temp. sensor as rotating controller Fresh air temp. sensor Left hand version 203 199 101 B A D C E 67 800 118 174 74 170 110 Right hand version 174 406 A B D 101 74 C Supply air ø160 mm Exhaust air ø160 mm Outdoor air ø160 mm Extract air ø160 mm Cooker hood ø125 mm 67 A B C D E 110 170 796 186 118 216 E SAP Appendix Q Approved Accessories Control panel CD p. 81 Exhaust Terminal Configeration Cable CEC p. 80 Cooker Hood Wall bracket p. 83 Specific Fan Power (W/l/s) Heat Exchanger Efficiency (%) Kitchen +2 Additional wet room 1.68 75 Kitchen +3 Additional wet room 1.50 77 Kitchen +4 Additional wet room 1.47 78 Kitchen +5 Additional wet room 1.45 79 Kitchen +6 Additional wet room 1.49 81 Kitchen +7 Additional wet room 1.57 81 63 64 | Heat Recovery unit Systemair Residential Ventilation Systems VR 700 DCV • High efficiency heat recovery unit without need for defrosting will give the highest average efficiency over the year • Energy efficient fan motors with modern EC technology • Operation from user friendly control panel(s), type CD with LCD-display, included • Separate setting of supply and extract airflow • Constant airflow and balance between extract and supply air • Changes automatically to summer operation with no heat recovery • Flexible installation. No need for condensation drain • Modbus communication via RS-485 Art-no. The VR 700 DCV is designed for installation in laundry room, storeroom or cupboard. The unit is double skinned, fully insulated and with complete control functions, high efficiency rotating heat exchanger, thermostat operated re-heater battery and filters. 12425 Supply VR 700DCV The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling). Surrounding Mid-frequency band, Hz LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k Extract 57 42 45 55 51 42 40 32 26 Supply 72 55 60 64 65 66 65 60 53 Surrounding 50 36 43 45 42 43 40 33 28 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. Extract VR 700 DCV VR 700DCV Voltage/Frequency Power consumption per fan at operation point SFP V/50 Hz W 230 ca. 130 450 m³/h at 80 Pa kW/m³/s 2,05 Wh/m³ 0,6 Recommended fuse A 13 Input power, fan motor(s) W 2x240 Input power, electr. heating battery W 1670 Filter, supply air F 7, bag filter Filter, extract air G 3, bag filter Weight / incl. packaging kg 72,6 Dimension (L x B x H) mm 918 x 517 x 800 Connection DN 200 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme F7 VR EF G3 ETS SF EH SS OT ET EHS FS Filter fresh air Rotating heat recovery unit Extract fan Filter extract air Extract air temp. sensor Supply fan Electric heater Supply air temp. sensor Overheating thermostat Emergency thermostat Temp. sensor as rotating controller Fresh air temp. sensor Dimensions A 181 800 150 C Approx. 800 118 176 517 918 Accessories Control panel Cable Wall bracket CD p. 81 CEC p. 80 WBK p. 81 A B C D B 202 Supply air Exhaust air Outdoor air Extract air 280 ø200 (4x) 216 50 D 65 66 | Heat Recovery unit Systemair Residential Ventilation Systems VSR 300 • High efficiency heat recovery unit without need for defrosting • Energy efficient fan motors with modern EC technology • Operation from user friendly control panel, type CD with LCD-display as accessory • Separate setting of supply and extract airflow • Constant airflow and balance between extract and supply air • Changes automatically to summer operation with no heat recovery • Flexible installation. No need for condensation drain • Modbus communication via RS-485 Art-no. The VSR 300 is double skinned, fully insulated and with complete control functions, high efficiency rotating heat exchanger, thermostat operated re-heater battery and filters. Energy efficient fans with EC motors will reduce energy consumption for transportation of ventilation air by approx. 50 % compared to traditional AC motors. Modern technology gives low SFP factor (Specific Fan Power) as well as constant airflow and balance between extract and supply air. 19427 Supply Surrounding Mid-frequency band, Hz SFP 2,5 SFP 2,0 SFP 1 ,2 SFP LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k Supply 67 57 59 60 57 62 58 53 49 Extract 53 41 49 49 44 44 42 34 27 Surrounding 48 30 38 42 38 42 42 34 29 1,5 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. Extract VSR 300 Voltage/Frequency Power consumption per fan at operation point SFP V/50 Hz W 230 ca. 50 270 m³/h at 80 Pa kW/m³/s 1.25 Wh/m³ 0.35 Recommended fuse A 10 Input power, fan motor(s) W 2 x 83 Input power, electr. heating battery W 1670 Filter, supply air F 7 Filter, extract air G 3 Weight kg 61 Dimension (L x H x D) mm 1120 x 582 x 461 Connection DN 160 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme F7 Filter fresh air VR Rotating heat recovery unit EF Extract fan SF Supply fan ETS Extract air temp. sensor EH Electric heater G3 Filter extract air SS Supply air temp. sensor OT Overheating thermostat ET Emergency thermostat EHS Temp. sensor as rotating controller Dimensions 1120 1040 160 112 136 602 582 178 188 231 505 461 281 Accessories Control panel Cable Wall bracket CD p. 81 CEC p. 80 WBK p. 81 67 | Heat Recovery unit Systemair Residential Ventilation Systems VSR 500 • High efficiency heat recovery unit without need for defrosting • Energy efficient fan motors with modern EC technology • Separate setting of supply and extract airflow • Constant airflow and balance between extract and supply air • Changes automatically to summer operation with no heat recovery • Flexible installation. No need for condensation drain • Inspection hatch on both sides • Modbus communication via RS-485 • Control panel CD necessary Art-no. The VSR 500 is double skinned, fully insulated and with complete control functions, high efficiency rotating heat exchanger, thermostat operated re-heater battery and filters. Modern technology gives low SFP factor (Specific Fan Power) as well as constant airflow and balance between extract and supply air. 19441 Supply The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling). Surrounding Mid-frequency band, Hz SFP 2,5 SFP 2, SFP 1,5 SFP 0 LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k Extract 62 44 50 57 58 49 47 40 29 Supply 77 61 65 68 70 70 70 66 61 Surrounding 54 36 44 45 50 46 46 42 41 1,2 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. Extract SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. VSR 500 Voltage/Frequency Power consumption per fan at operation point SFP η 68 V/50 Hz W 230 ca. 95 450 m³/h at 100 Pa kW/m³/s 1.44 Wh/m³ 0.4 Recommended fuse A 13 Input power, fan motor(s) W 2 x 169 Input power, electr. heating battery W 1670 Filter, supply air F 7 Filter, extract air G 3 Weight kg 72 Dimension (L x H x D) mm 1120 x 632 x 551 Connection DN 200 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme F7 Filter fresh air VR Rotating heat recovery unit EF Extract fan SF Supply fan ETS Extract air temp. sensor EH Electric heater G3 Filter extract air SS Supply air temp. sensor OT Overheating thermostat ET Emergency thermostat EHS Temp. sensor as rotating controller Dimensions 1120 1040 207 123 179 652 632 208 178 276 276 595 551 345 Accessories Control panel Cable Wall bracket CD p. 81 CEC p. 80 WBK p. 81 69 70 | Heat Recovery unit Systemair Residential Ventilation Systems VX 400 & 700 E / EV • User friendly controlling by one or several control panels. • Integral filter monitor • Automatic de-frosting for all operating conditions. • EU7 fine filter for supply-air • Cross flow heat exchanger • Demand control • Inspection covers on both side Art-no. Art-no. left / Right VX 400 E Horizontal VX 700 E Horizontal 12040 12042 VX 400 EV Vertical VX 700 EV Vertical 12045 / 12044 12049 / 12048 Technical data Voltage/Frequency V/50Hz Fans for supply and extract air, control system, cross flow heat exchanger, thermostat operated pre- and re-heater battery and filters are standard. Summer block is available as an accessory when heat recovery is not required. Air flow, supply air temperature and filter change interval are set from one (or several) external mounted control panels type CE. Lamp indicators on the CE panel shows chosen fans and temperature settings, whether the heating battery is in operation and if filters need to be replaced. The lamps also help to show if any faults would occur. A separate timer can be connected for programming day and night operation. A CO2 or presence sensor (potential free contact) can be connected for demand control. The casing is manufactured in galvanised sheet steel, double skinned with 50 mm of insulation in the main body and 30 mm in the access covers. vx 400 e VX 400 EV VX 700 E VX 700 EV 230 230 230 230 Phase — 1 1 1 1 Input power, fan motors W 2x152 2x138 2x308 2x315 Input power, preheater battery kW 1.67 1.67 2.67 2.67 Input power, electrical heater battery kW 1.67 1.67 2.67 2.67 Fuse A 10 10 16 16 Enclosure class IP 24 24 24 24 Weight Kg 48 52.6 67 69 Filter, supply air — F7 F7 F7 F7 Filter, extract air — Aluminium Aluminium Aluminium Aluminium accessories VX 400 E VX 400 EV VX 700 E VX 700 EV Control panel CE CE CE CE Cable w/plug 12m CEC CEC CEC CEC Diverging plug CED CED CED CED Timer T 120 T 120 T 120 T 120 Timer frame F-T 120 F-T 120 F-T 120 F-T 120 Week timer 7592H 7592H 7592H 7592H Filter F7 (Supply air) BFVX 400E/EV EU7 BFVX 400E/EV EU7 BFVX 700E/EV EU7 BFVX 500/700 E/EV EU7 Filter G3 (Extract air) PFVX 400 E/EV PFVX 400 E/EV PFVX 400 E/EV PFVX 500/700 Duct cover VTVX 400 VTVX 400 VTVX 500/700 VTVX 500/700 Combi grille CVVX 160 CVVX 160 CVVX 200 CVVX 200 Summerblock SBVX 400 SBVX 400 SBVX 500/700 SBVX 500/700 Condensate tray KVSX 200-700 KVSX 200-700 KVSX 200-700 KSVX 200-700 Heat Recovery unit | Systemair Residential Ventilation Systems 1189 1080 149 327 102 267 ø160 155 172 ø160 ø160 600 281 ø125 163 179 dimensions vx 400 e 112 50 164 163 vx 400 eV 500 170 600 260 ø200(x4) 250 vx 700 eV 51 170 315 115 1189 1080 171 vx 700 e 110 250 71 72 | Heat Recovery unit Systemair Residential Ventilation Systems Performance VX 400 E Supply air Extract air Temperature efficiency With air ratio 1:1 and air humidity at 50% A A B B C C VX 400 E OCTAVE BAND (mid-frequency Hz) Tot LwA dB(A) 63 125 250 500 1k 2k 4k 8k A B C A B C A B C A B C A B C A B C A B C A B C A B C Supply air 72 65 54 64 54 47 63 59 47 63 55 44 62 55 45 64 59 49 64 55 43 58 51 37 53 45 28 Extract air 58 51 42 36 36 34 47 41 31 55 47 35 54 46 38 47 40 32 40 32 22 33 23 8 24 15 6 Surrounding 52 46 36 36 29 22 46 41 31 43 36 25 47 41 32 44 37 28 39 31 21 29 22 7 22 15 0 VX 400 EV Supply air Extract air Temperature efficiency With air ratio 1:1 and air humidity at 50% A A B B C C VX 400 EV OCTAVE BAND (mid-frequency Hz) Tot LwA dB(A) Supply air 63 125 250 500 1k 2k 4k 8k A B C A B C A B C A B C A B C A B C A B C A B C A B C 70 62 53 58 50 43 59 54 44 63 55 44 61 53 45 64 58 47 64 52 42 56 47 33 48 37 22 Extract air 61 54 44 54 46 40 57 52 40 52 44 32 52 45 36 49 43 32 47 37 25 35 23 7 24 15 8 Surrounding 51 44 33 40 31 23 42 36 26 44 36 25 41 34 26 44 40 28 43 33 21 36 27 13 29 19 9 Heat Recovery unit | Systemair Residential Ventilation Systems VX 700 E Supply air Extract air Temperature efficiency A A With air ratio 1:1 and air humidity at 50% B B C C VX 700 E OCTAVE BAND (mid-frequency Hz) Tot LwA dB(A) 63 125 250 500 1k 2k 4k 8k A B C A B C A B C A B C A B C A B C A B C A B C A B C Supply air 75 71 57 64 59 50 69 65 52 68 63 47 66 61 44 67 64 51 67 63 48 64 59 42 57 52 31 Extract air 60 54 44 34 34 31 49 46 34 55 48 40 55 49 37 51 45 34 46 39 24 43 33 17 36 27 24 Surrounding 59 48 39 46 33 25 52 43 34 52 41 32 55 44 34 45 36 27 45 34 24 40 31 16 38 22 24 VX 700 EV Supply air Extract air Temperature efficiency With air ratio 1:1 and air humidity at 50% A A B B C C VX 700 EV OCTAVE BAND (mid-frequency Hz) Tot LwA dB(A) 63 125 250 500 1k 2k 4k 8k A B C A B C A B C A B C A B C A B C A B C A B C A B C 73 64 54 63 55 47 64 55 45 66 56 45 66 56 48 65 57 48 66 56 46 51 50 38 55 40 28 Extract air 69 65 54 63 61 51 62 58 48 64 57 46 61 54 45 53 48 40 50 43 33 45 38 29 37 30 24 Surrounding 58 51 41 46 40 31 50 45 34 55 46 35 49 42 33 46 40 32 44 37 27 43 34 24 38 28 24 Supply air Control panel Cable Timer Timer Frame for wallmounting CE p. 80 CEC p. 80 Timer p. 80 TFV p. 80 RCE p. 80 73 | Heat Recovery unit Systemair Residential Ventilation Systems VTC 300 • High efficiency heat recovery unit • Energy efficient fan motors with modern EC technology • Operation from user friendly control panel(s), type CD with LCD-display, included • Separate setting of supply and extract airflow • Changes automatically to summer operation with no heat recovery • Automatic defrosting • Modbus communication via RS-485 Art-no. VTC 300 R VTC 300 L 2480 2481 The SAVE VTC 300 is designed for installation on wall, in laundry room, storeroom. The unit is double skinned, fully insulated and with complete control functions, high efficiency counterflow heat exchanger and filters. Modern technology gives low SFP factor (Specific Fan Power). The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling). 9294/9295T Supply Surrounding P 2, 5 Mid-frequency band, Hz SF P SF 2,0 LwA dB(A) Tot 63 125 250 500 1k 2k 4k 8k Extract 56 45 43 54 45 46 43 30 22 Supply 66 47 53 62 59 57 60 53 46 Surrounding 47 28 35 44 40 37 35 28 22 SFP 1,5 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. SFP 1,2 SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. VTC 300 Exhaust Voltage/Frequency 9294/9295F 74 Power consumption per fan at operation point SFP V/50Hz W 230 ca. 55 I ca. 70 350 m³/h at 80 Pa kW/m³/s 1,14 1,41 Wh/m³ 0,3 0,39 Recommended fuse A 10 Input power, fan motor(s) W 2 x 85 Filter, supply air G4 F7 Filter, extract air G4 F7 Weight kg 72 Dimension (L x B x H) mm 762 x 616 x 857 Connection DN 160 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme EF G4 ETS SF SS OT ET ELH FS DB HE exhaust air fan supply air filter temperature sensor, exhaust air supply air fan supply air sensor overheating sensor safety temperature limiter electric reheater supply air temperature sensor bypass flap heat exchanger Dimensions VTC 300 - Left hand version 616 762 139 139 B C Supply air Exhaust air Outdoor air Extract air 406 421 616 A B C D 279 131 131 802 857 553 A SAP Appendix Q Approved D Exhaust Terminal Configeration Specific Fan Power (W/l/s) Heat Exchanger Efficiency (%) Kitchen +1 Additional wet room 0.89 75 Ø160 (4x) Accessories Control panel CD p. 81 Damper EFD p. 80 Cable CEC p. 80 Kitchen +2 Additional wet room 0.81 76 Kitchen +3 Additional wet room 0.79 76 Kitchen +4 Additional wet room 0.83 78 Kitchen +5 Additional wet room 0.90 80 Kitchen +6 Additional wet room 1.01 80 Kitchen +7 Additional wet room 1.14 80 75 76 | Heat Recovery unit Systemair Residential Ventilation Systems VTC 700 • High efficiency heat recovery unit • Energy efficient fan motors with modern EC technology • Operation from user friendly control panel(s), type CD with LCD-display as accessory • Separate setting of supply and extract airflow • Changes automatically to summer operation with no heat recovery • Automatic defrosting • Modbus communication via RS-485 Art-no. VTC 700 R VTC 700 L 2173 2174 Supply The SAVE VTC 700 is designed for installation on wall, in laundry room, storeroom. The unit is double skinned, fully insulated and with complete control functions, high efficiency counterflow heat exchanger and filters. Modern technology gives low SFP factor (Specific Fan Power). The unit will automatically alternate between normal operation with heat recovery and summer operation without heat recovery. This solution will also automatically recover chilled indoor air (from cooling). Surrounding Mid-frequency band, Hz P SF 2,5 Tot 63 125 250 500 1k 2k 4k 8k Extract 65 44 50 56 57 59 61 51 45 Supply 50 34 40 46 41 43 38 24 21 Surrounding 47 24 35 42 40 40 39 32 25 0 SFP 2, SFP 1 ,6 SFP 1 ,5 SFP Exhaust LwA dB(A) SFP 0,6 SF 0,9 P1 ,2 Sound data The sound data tables indicate the sound power level LwA, which should not be confused with the sound pressure level LpA. SFP= Specific Fan Power [kW/m3/s] The SFP value stated applies to the complete unit. VTC 700 Voltage/Frequency Power consumption per fan at operation point SFP V/50Hz W 230 ca. 95 I ca. 100 700 m³/h at 80 Pa kW/m³/s 0,97 1,02 Wh/m³ 0,27 0,28 Recommended fuse A 10 Input power, fan motor(s) W 2 x 168 Filter, supply air Filter, extract air Weight kg G4 F7 G4 F7 150 Dimension (L x B x H) mm 1170 x 860 x 1214 Connection DN 250 Heat Recovery unit | Systemair Residential Ventilation Systems Scheme Fresh air Exhaust air Supply air ET OT SS SF G4 EF G4 ETS SF SS OT ET ELH FS DB HE ELH ETS FS Extract air EF G4 HE exhaust air fan supply air filter temperature sensor, exhaust air supply air fan supply air sensor overheating sensor safety temperature limiter electric reheater supply air temperature sensor bypass flap heat exchanger DB Dimension VTC 700 - Left hand version 860 1170 1214 1088 780 450 176 211 211 180 C 576 571 B A A B C D Supply air Exhaust air Outdoor air Extract air D ø250(4x) Accessories Control panel Damper Cable CD p. 81 EFD p.80 CEC p. 80 77 | ControlsSystemair Residential Ventilation Systems Control panel CE Only for VR-250 ECH/B • Easy operation • 3 or 4 step speed control • 5 steps temperature control (12-22 °C) • Setting of filter replacement intervals (3, 6, 9 months) • Dimensions: 155 x 8.5 mm This remote control is necessary for VR 250 ECH/B. It is also possible to connect more than one remote control at the same time. The remote control CE has an appealing design and is functionally and easy to operate. The fan speeds and the supply temperatures can easily be adjusted by the handy keyboard. Indicator lights show the chosen settings and the operation of the electric heater. A separate control lamp shows when the filter should be changed. A low voltage cable with plug-in connections allows an easy installation. The remote control can be mounted on-wall (by a corresponding mounting frame) or in-wall (in-wall socket as an accessory). The mounting frame (accessory) for on-wall mounting has a height of app. 20 mm. For application of heat recovery units in kindergartens, schools or office rooms, a separate time switch can be connected for depression or normal operation. It is possible to deactivate depression operation for 3 hours by a so called “party button”. A low voltage wire (2 x 0.8 mm²) must be connected between time switch and unit for depression operation. CE Art-no. CEC - Cable c/w Plug 12486 RCE Cable to connect CE Controller to unit Frame for wallmounting of CE Control panel. CEC 12m Cable 6m Cable Diverging plug Timer RCE 12398 Art-no. 12283 12276 12399 An electronic day/week timer with an automatic summer/winter time setting. Frame “F7592H” is available for wall mounting. TFV TFV, Timer suitable from 0-6 hours. TFV 12277 Art-no. Timer Art-no. 5589 95 EFD 210 10 73 100 50 67 Circular shutter damper The damper is provided with 230 V motors with spring-return actuators. EFD are made in leakage performance class 3 according to EN 1751:1998 Annex C.2. Outdoor/exhaust air damper have the function to prevent the hot water battery to freeze. EFD connects to a connection block inside the electrical box. 170 130 25 øA 78 45 45 175 EFDNo. øA 1607122 160 2007162 200 250 250 6748 Controls | Systemair Residential Ventilation Systems MTP 20/20K No. 4744 Only for VR-300 ECH/B & VTC Low E Control panel CD No. 207487 For VR-400/700 and Save VTC /VSR units • Plain text display • Easy operation • 3 steps control (steps free selectable) • Supply and exhaust air ventilator can be equalised • Temperature control 12-22 °C • Weekly time switch integrated • Setting of filter replacement intervals • Dimensions: 80x88x20mm (WxHxD) Control Panel for almost all units! Potentiometer for speed control in 3-steps, Min 3-7V, Norm 5-9V, 10V - Combined flush or surface mounting For the manual control of speed and air flow of electrical fans with 0-10V output. The jetproof IP 54 enclosure is achieved with the included surface mounting case. (Flush-mounting without the surface mounting case,gives a splash proof IP 44 enclosure also suitable for highly demand environments as bathrooms etc). This remote control is necessary for (type -DC). It is possible to connect up to 3 remote controls at the same time. (also suitable for monitoring the differential pressure in combination with wood stoves). Remote control CD is already integrated in the front of wall units (type – DCV). It is possible to connect up to two remote controls type CD. Automatic control units are already installed and presetted in the units. The function of these relays can be set with the remote control CD. Additional close and push-button contacts (heating ON/OFF, external ON/OFF, filter reset, vacation operation) are fixed preset and can be used when needed. The remote control CD has an appealing, functional design and is easy to operate by a selection knob and two buttons. The unit can be operated manually or by the integrated time switch for day and night operation. Each external cooling and heating coil can be controlled by a 0-10 V signal (power supply 24V on site). The control program offers two user levels: user level and service level. The user level allows adjusting air volume and temperature; filter replacement intervals, heating and cooling operation etc. can be read. Parameters and basic settings can be changed in the service level. A 4-wire low voltage wire (2x2x0.8 mm²) as a control cable is sufficient. Use a shielded cable when installed in combination with a 230 V cable. The built-in control unit enables to control speeds via potential-free relays WBK 315/355 Wall bracket No. 2721 No. 12891 Wall bracket for VR 250. Wall mounting bracket. Manufactured from galvanised steel. The corners are welded. Available in pairs. For VR-400/70 DC 79 80 | Heating & Cooling Coils CB - Electric re-heater coil Systemair Residential Ventilation Systems CB – circular electric duct heater down to 0.5 m/s air velocity The CB can be used for preheating and reheating air in residential ventilation systems. The casing is made of Aluzinc-coated steel and the heater elements are of stainless steel (EN1.4301). The CB has a built in regulation for easy installation (protection IP43). It is equipped with two overheating protections, one with automatic reset and one with manual reset. Not to lose heated air through the casing, it confirms air tightness class C. The max. outlet air temperature is limited to 50°C. Available is sizes 100mm Dia to 500mm Dia Accessories CB Product Range Degree of protection Duct sensor TG-K330 0-30°C IP20 Duct sensor TG-K360 0-60°C IP20 Room sensor TG-R430 with setpoint adjustment 0-30°C IP30 Room sensor TG-R530 0-30°C IP30 Pressure switch DTV200 incl. connection kit 20-300 Pa; max. 5A, 230V~ IP54 VBC - Water LPHW re-heater coil VBC - Water-heating battery for heating air in ventilation systems with circular ducts. Aluzinc-coated casing, heat transmission element with copper tubes and aluminium fins. Removable cover for cleaning the unit. The water-heating battery can be installed in a horizontal or a vertical duct with optional direction of airflow. Max operating temperature 150 °C Max operating pressure 1,6 MPa (16Bar) 2-rows battery Available is duct sizes 100mm to 500mm diameter CWK - Water-cooling coil CWK - Water-cooling battery for circular ducts Casing of galvanised sheet steel with copper tubes and aluminium fins. Inspection covers for easy cleaning and maintenance. Connection sleeves with rubber seal. Max operating temperature 150 °C Max operating pressure 1,6 MPa (16Bar) Available is duct sizes 100mm to 400mm diameter Cooker Hoods | Systemair Residential Ventilation Systems A modern and functional cookerhood with a high efficiency even at a low airflow (75% at 140 m3/h). The aluminium Cooker hood 251-14 Functional design and high efficiency, even at a low airflow. Developed for connection to Systemair heat recovery unit type VR-300 ECV/B. Modern cookerhood with curved front and good working light from 11 W compact light tube. No sharp edges allows for Connections: Voltage/frequency 230V/50 Hz 2 x 1,0 mm² Ductwork connection spigot DN 125mm easy cleaning. The cookerhood is functional with deep side members and shade in tempered glass. This makes the cookerhood efficient, even at low airflows (75% at 140 m3/h). The aluminium grease filter can easily be removed for cleaning in warm soapy water or in dish washer. The cookerhood is equipped with switch for timer control of damper, 5 to 60 minutes, and signal cable for damper/fan speed control (airflow) in the ventilation unit. This model, for installation under kitchen cupboard, is available in white or stainless steel. white 12023 stainless steel 12929 80 This model is available white painted or in stainless steel. 70 Functional design and high efficiency, even at a low airflow. Developed for connection to Villavent heat recovery unit type VR-250 EH/B and VR-400 EV/B and to central extract fans serving more than one apartment. 9,5 383 299 16 160 filter can easily be removed for cleaning in warm soapy water or in dish washer. A patented, adjustable damper solution allows for individual setting of airflow at normal ventilation. The cookerhood has a damper with a timer (5-60 min.) and a wired out signal to force the airflow in the airhandling unit. 598 white 4742 stainless steel 4741 232 Cooker hood 251-10/B The TSL-1/EC cookerhood is designed to be used with the VTC Low E Heat Recovery Unit. The units is complete with Fan speed control switch, Hob light switch, Metal Grease filter section and connection plugs for quick installation to HRU. To activate the extraction, simply slide the cookerhood telescopic section towards you. The units front comes in white as standard, with a stainless steel cover plate as an optional extra. 22 14236 50 13 52072 stainless steel cover plate 190 white 511 480 Cooker hood TSL-1/EC 81 82 | Duct work & FittingsSystemair Residential Ventilation Systems Systemair Duct Systems Very flexible Spiral seam pipe or plastic pipe system Systemair offers spiral seam pipes in round and oval versions (flat duct) and Systemair-Flex+ plastic pipes, “The NEW semi-rigid”. All inner sides are smooth and therefore aerodynamical and easy to clean. Dimensioning of duct systems The dimensioning of the ducts for the ventilation system is made according to the requirements of the unit (calculation of the required supply air according to DIN 1946-6) and according to the situation in the building. Flow engineering and acoustic properties have first priorities. The duct installation has to be coordinated early enough with other crafts on site. The duct size depends on the air volume. To avoid high pressure losses and unwanted noise, we recommend an air velocity of max. 3 m/s in the main duct. When round, rectangular or oval ducts are used, the air velocity is lower at the same pressure loss in the duct. Different diameters must not be proportional installed. The pressure differences between the longest and the shortest sections have to be reduced to guarantee the previously defined air flow for all air outlets. Round pipe (spiral seam pipe) with telescopic pipe For duct systems with spiral seam pipes, Systemair uses folded spiral seam pipes with a length of 1.2 m as well as telescopic pipes. The elements are equipped with rubber-lip seals. The length of the telescopic pipe can be freely adjusted. The most important advantage of this duct system is that it can be installed without cutting or trimming work. This saves installation time and makes maintenance and cleaning easier. All joints have to be fixed by sheet metal screws and also sealed with tape. Oval duct / flat duct Flat ducts are made of galvanized steel sheet. The elements are made of stainless steel and are connected by a plug-in system. Fixing and sealing is made by cold shrink tape. Available sizes: System 100 (129 x 52); length 3 m System 151 (208 x 52); length 3 m Systemair Flex+ - the flexible plastic pipe The Flex+ pipe is made of physiologically and toxicologically safe PVC with no recycling materials. Thus, it is neutral in odour, free of halogens, emission-free, antistatic and antibacterial. Easy and time saving installation by a click system. Hermetically sealed connections ensure an absolutely air tight system without further sealing work. Therefore, it works economically and hygienically because no air can leak and no other substances can enter from outside. Deliverable sizes: Diameter DN 50, 63, 75, 90 Systemair ISO+ - a perfect combination of heat and sound insulation Outer sheath made of polyethylene with high density (HDPE); inner sheath made of polyolefin with closed cell structure. Flexible fast clamp made of EPDM. The special design of the pipes provides thermical and acoustic insulation. Systemair Residential Ventilation Systems This pipe should be preferably used as a connection between unit and facade (fresh and extract air) and in unheated areas. Available nominal widths (inner diameter): DN 125 and DN 180 Pipe kit available Ventilation systems from Systemair are individually planned for each building. The air volume is calculated according to DIN 1946-6, the unit is accordingly specified and the duct system is planned inclusive silencers, insulation, outlets and mounting material. The duct system is assembled and delivered according to the material list of the planning. Duct work & Fittings | 83 | SystemairFlex+ Plastic Duct SystemairFlex+ plastic duct system „The NEW semi-rigid“ Technical data SystemairFlex+ Pressure loss diagram: Nominal dimensions: 25 Air duct DN50 [mm] 20 15 D inside [mm] D outside [mm] DN 50 51 41 DN 63 64 54 DN 75 76 64 DN 90 91 78 DN63 [mm] Pressure loss (Pa/m) 10 DN75 [mm] 5 DN90 [mm] 0 0 5 10 Capacity (m³/h) 15 20 25 30 35 40 45 50 Pressure loss data: DN50 DN63 DN75 DN90 Air flow in m³/h at ca.: 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 1 duct 10 m³/h 12.5 m³/h 15 m³/h 15 m³/h 20 m³/h 25 m³/h 22 m³/h 28 m³/h 34 m³/h 34 m³/h 42 m³/h 51 m³/h 2 ducts 20 m³/h 25 m³/h 30 m³/h 30 m³/h 40 m³/h 50 m³/h 44 m³/h 56 m³/h 68 m³/h 3 ducts 30 m³/h 37.5 m³/h 45 m³/h 45 m³/h 60 m³/h 75 m³/h 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2m/s 2.5 m/s 3 m/s 2 7.6 10.0 12.6 4.0 5.6 8.4 2.6 4.0 6.0 2.6 4.0 5.4 4 15.2 20.0 25.2 8.0 11.2 16.8 5.2 8.0 12.0 5.2 8.0 10.8 Length of duct (m) 84 6 22.8 30.0 37.8 12.0 16.8 25.2 7.8 12.0 18.0 7.8 12.0 16.2 8 30.4 40.0 50.4 16.0 22.4 33.6 10.4 16.0 24.0 10.4 16.0 21.6 10 38.0 50.0 63.0 20.0 28.0 42.0 13.0 20.0 30.0 13.0 20.0 27.0 12 45.6 60.0 24.0 33.6 50.4 15.6 24.0 36.0 15.6 24.0 32.4 53.2 28.0 39.2 58.8 18.2 28.0 42.0 18.2 28.0 37.8 60.8 32.0 44.8 20.8 32.0 48.0 20.8 32.0 43.2 36.0 50.4 23.4 36.0 54.0 23.4 36.0 48.6 14 16 18 Pressure (Pa) SystemairFlex+ Plastic Duct | Applications In the concrete: Concrete floor plates Cast-in-place concrete In a false ceiling: T T Connections in plasterboard T min. h = 80 mm In a reduced wooden ceiling: T In a modular ceiling: 85 | SystemairFlex+ Plastic Duct Flex+ horizontal terminal 6 connections 18 connections DN63 E B Flex+HV 18xDN63/160 D 12 connections ⌀180 Flex+HV 12xDN75/160 DN90 Flex+HV 6xDN90/160 Art-no. 310252 310978 310980 A 655 745 765 B 420 505 515 C 80 80 80 D 177 145 145 E 175 145 145 Connections 18 + 1x DN160 12 + 1x DN160 6 + 1x DN160 DN63 DN75 Flex+HV 8xDN75/180 DN90 Art-no. 311996 311999 - A 384 105 105 B 80 70 77,5 C 192 165 165 Connections 12 + 1x DN180 8 + 1x DN180 4 + 1x DN180 45 C 45 A DN75 Flex+ horizontal terminal 4 connections 12 connections A C 8 connections Flex+HV 12xDN63/180 C B Flex+ horizontal terminal 300 47 Horizontal terminal with 9 connections DN63 and 1x DN 160 with oval connection system 151 at the side. 27 160 105 86 177 Bezeichnung Art-no. Flex+HV 9xDN63/160 310250 SystemairFlex+ Plastic Duct | Flex+ horizontal terminal 300 28 48 DN75 DN63 DN75 DN90 Art-no. 304030 311399 311400 A 105 105 105 B 27 70 77,5 Connections 9x DN63 + 1x oval System 151 6x DN75 + 1x oval System 151 3x DN90 + 1x oval System 151 Flex+HV 9x63/ System 151 DN63 DN90 Flex+HV 3x90/ System 151 A B Flex+HV 6x75/ System 151 Flex+ horizontal terminal, variable Customised distributor box Connections can be chosen as required. Dimensions Code 3x63 6 2x75 7 1x90 9 endcap D connector K spigot Ø125 2 spigot Ø150 5 spigot Ø160 6 spigot Ø180 8 endcap D Flex+ vertical terminal B C A 600 DN63 DN75 Art-no. 309470 310977 A 180 160 B 105 105 C 175 205 Connections 18 + 1x DN180 12 + 1x DN160 300 150 Flex+VV 18x63/180 Flex+VV 12x75/160 87 | SystemairFlex+ Plastic Duct 79 Flex+ diverter valve connection 149 248 130 180 260 229 128 1 connection Art-no. Length of column Connections DN63309465 Flex+ US 3x63/125/180 180-230 3x DN63 + 1x DN125 DN75310982 Flex+ US 2x75/125/180 180-230 2x DN75 + 1x DN125 DN90310985 Flex+ US 1x90/125/180 180-230 1x DN90 + 1x DN125 2 connections 92 108 250 2 connections 1 connection 92 108 250 3 connections 250 229 260 Stutzenlänge Length of column DN63309463 Flex+ US 3x63/125/50 50 DN63309464 Flex+ US 3x63/125/70 70 DN75310983 Flex+ US 3x75/125/50 50 DN75310984 Flex+ US 2x75/125/70 70 DN90310986 Flex+ US 1x90/125/50 50 DN90310987 Flex+ US 1x90/125/70 70 Connections 3x DN63 + 1x DN125 2x DN75 + 1x DN125 1x DN90 + 1x DN125 24 128 50 / 70 79 92 130 Art-no. Flex+ diverter for plasterboard construction 248 250 130 229 260 79 92 88 Installation example Art-no. Connections DN63311995 Flex+ US 3x63/125 - 13mm flat 3x DN63 Wall diverter for lightweight constructions. Inside wall width min. 80 mm. Without inner bridge for stabilisation. Thus, all valves can be inserted. Not to be used for installation in/on the floor. SystemairFlex+ Plastic Duct | Flex+ diverter For pipe laying under the ceiling or ceiling void installation. Art-no. Connections DN63312503 Flex+ US-W 3x63/125 Valve connection DN125 Installation example Flex+ adapter Connection to terminal and diverter is possible. Can be used as a transition from Flex+ to valve. Art-no. DN63 312504 Flex+ Adapter 3x63/125 asym. Terminal and adaptor, mounted Flex+ fitting Connections DN125 Fitting to connect two terminals, adapter and terminal or terminal and diverter. Use instead of flexible pipe fittings. Art-no. Flex+ fitting for components Flex+ plastic duct, flexible 312505 Flex+ duct insulation Art-no. Name DN 50 50 m roll Flex+ FR50 309462 310988 DN 63 50 m roll Flex+ FR63 309461 DN 50 / 60 m Flex+ RI 50/60 m DN 63 / 48 m Flex+ RI 63/48 m 310989 DN 75 50 m roll Flex+ FR75 310975 DN 75 / 40 m Flex+ RI 75/40 m 310990 DN 90 50 m roll Flex+ FR90 310976 Flex+ duct fitting Art-no. Flex+ transition Name Art-no. DN 50 Flex+ RV50 309468 DN 63 Flex+ RV63 309467 DN 75 Flex+ RV75 310991 DN 90 Flex+ RV90 310992 Transition piece from 63 on 50 mm. Art-no. Flex+ RED 63/50 309466 89 | SystemairFlex+ Plastic Duct Flex+ duct cutter Mounting set for distributor box 20 453 270 310993 DN 63 Flex+ RS63 309475 DN 75 Flex+ RS75 310994 DN 90 Flex+ RS90 310995 6 DN 50 Flex+ RS50 80 NameArt-no. 85 Art-no. Flex+ BSV 309474 Flex+ angle plate 90° A 90 A DN90 DN75 NameArt-no. A DN63 - 1 duct Flex+ BS1 90°/1xDN63 309472 153 DN63 - 3 duct Flex+ BS1 90°/3xDN63 309473 DN75 - 2 duct Flex+ BS1 90°/2xDN75 311402 DN90 - 1 duct Flex+ BS1 90°/1xDN90 311401 153 189 226 Accessories ducts, circular Screw thread Poly-nail tape Self-tapping screw thread Art-no. Poly-nail tape Art-no. 309474 Poly nail tape, width 1.5 cm, roll: 15 m Duct tape packaging unit 59090 SCR4.2/13mm 1000 pcs. 59094 SCR4.2/16mm 1000 pcs. Slotted Banding Art-no. Art-no. Duct tape Cloth 50mm 57590 57617 Duct tape Foil 50mm 52978 AS401 PVC Tape 38 x 33 White 54212 25mm x 25m Slotted Band FB-25 Circular Ducts | Circular ducts, galvanized VSP Rigid Spiral Duct DN No. ød t L 10052509 100 0,6 3000 12552510 125 0,6 3000 16052512 160 0,6 3000 20052514 200 0,6 3000 With beadings for reinforcement Duct can be cut to various lengths Telescopic duct IS, insulating sleeve DN Length DN 100 DN 125 DN 160 DN 200 0,25 / 0,36 m 12109 12110 12111 12112 0,63 / 1,14 m 12113 12114 12115 12116 Bend 90° L rm 12154 125 12151 12155 160 12152 12156 200 12153 12157 10 DNNo. ød 10012062 100 No. ød1 L kg 10012085 100 150 0,6 12512086 125 190 0,8 125200140 125 150309037 150 160200817 160 200200818 200 16012087 160 240 1,4 20012088 200 300 2,1 36 36 ød1 Bend 45° EB, end cap L ød1 50 mm 12150 MF, external connector DN rm 30 mm 100 The insulating hose is available with 30 mm or 50 mm mineral wool for all sizes. L rm = 1,5xd1 Insulation L DNNo. ød1 L kg 10012089 100 41 0,3 12512090 125 52 0,4 16012091 160 66 0,6 20012092 200 83 0,9 40 ød DNNo. ød 100200820 100 125200821 125 16012093 160 20012094 200 91 | Circular Ducts Mounting frame NP, Connector with rubber seal No. ød 10012059 100 125201348 125 16012060 160 20012061 200 øD DN 35 35 RFU 35 5 Connector incl. rubber seal H T-piece with rubber seal Gasket (only RFP)) L L+70 No. ød1 H L kg 100 60 180 0,6 12512070 125 125 75 200 0,8 16012063 160 160 92 250 0,9 20012071 200 200 112 305 1,2 ød1 ød3 ød3 10012068 100 10012069 100 125 95 215 0,6 125 100 75 180 0,7 12512073 125 160 75 200 0,8 16012065 160 100 92 180 0,8 16012064 160 125 92 180 1,0 160305485 160 150 100 260 0,9 20012074 200 100 112 200 1,1 20012075 200 125 112 250 1,2 20012072 200 160 112 250 1,4 122 146 0,09 1506132 147 170 0,11 1606134 157 180 0,11 2006135 197 220 0,14 RFPNo. øD øA kg 1006125 97 120 0,08 1256126 122 146 0,10 1606127 157 180 0,12 2006128 197 220 0,16 Art-no. packaging unit 12456 Frame Ø100 mm 12457 Frame Ø125 mm 12458 Frame Ø160 mm 50780 Frame Ø150mm 50754 Frame Ø200mm Reducer seal kg 12512067 0,07 1256131 Reducer seal 1 ⌀d2 L kg 120 ⌀d1 T-piece with reduced outlet / passage DNArt-no. ød1 ød3 H øA 97 No. RFU and RFP mounting frame are made of galvanized steel sheet. RFP incl. rubber gasket for duct connection. T-piece DN øD 1006130 øA 92 L DN Duct cross Art-no. ød1 ød2 L kg 150/125305038 150 125 140 0,3 160/150305039 160 150 125 0,3 250/200305054 250 200 31 0,6 Reducer seal 2 L1 ⌀d ⌀d2 ød B H L DNArt-no. ød L L1 H B 125 12178 125 610 315 63 210 160 12179 160 647 315 80 300 L DN Art-no. ød1 ød2 L kg 100/8012080 100 80 60 0,2 125/10012081 125 100 92 0,3 160/10012079 160 100 125 0,5 160/12512078 160 125 110 0,4 200/12512082 200 125 133 0,6 200/16012077 200 160 110 0,5 Circular Ducts | UIS, Alu-flexible plain duct IS, Alu-flexible duct Compressed, double-sided sleeve Compressed Semi rigid flex with insulation Length / extractable length DN 100 DN 125 DN 160 DN 200 230 mm / 1 m 12121 12122 12123 12124 650 mm / 3 m 5631 5632 5633 5634 Length / Insulation DN 100 DN 125 DN 160 DN 200 IS Insulated 3 m / 25 mm 12125 12126 12127 12128 LFK Acoustic 3 m / 25 mm 12138 12139 12140 12141 Semi-Rigid Flex Duct - 3m Lengths (Semiduct) Description: Semi flexible, high quality, aluminium duct for use in all low / medium pressure systems and suitable for AC. Easy & Fast installation, tough and airtight. Construction: 1 x wound layer of tough corrugated aluminium, “Triple Locked” seams for air tightness & strength. Sizes 100mm to 250mm in 3m lengths Thermally Insulated Flex Duct - 10m Lengths (Isoduct) Description: Fully flexible, high quality, insulated aluminium laminated duct for use in commercial HVAC systems. Easy & Fast installation over round or oval connections. Tough and airtight with a smooth core for low friction loss and lower operation costs. Construction: Outer vapour barrier is 3 x layers of tough “aluminium / polyester laminates” plus flame retardant adhesive and spiral fibreglass reinforcement. The inner core has 5 x layers of tough aluminium / polyester laminates plus flame retardant adhesive encapsulating a copper plated high tensile steel wire helix. Sizes 100mm to 500mm dia in 10m lengths Acoustic / Thermal Flex Duct - 10m Lengths (Sonoduct) Description: Fully flexible, high quality, insulated aluminium laminated duct for use in commercial HVAC systems. Easy & Fast installation over round or oval connections. Tough and airtight with a smooth core for low friction loss and lower operation costs. Construction: Outer vapour barrier is 3 x layers of tough “aluminium / polyester laminates” plus flame retardant adhesive and spiral fibreglass reinforcement. The inner core has 5 x layers of tough aluminium / polyester laminates plus flame retardant adhesive encapsulating a copper plated high tensile steel wire helix. Sizes 100mm to 500mm dia in 10m lengths Flex Code Flex Type Fire safety Testing Temperature Range 100mm - 250mm 300mm - 500mm Isoduct Thermal BS476 (6.7&20) -30ºC to +140ºC +2.5Kpa to -0.4Kpa +2.5Kpa to -0.2Kpa Sonoduct Acoustic BS476 (6.7&20) -30ºC to +140ºC +2.5Kpa to -0.4Kpa +2.5Kpa to -0.2Kpa Semiduct Semirigid BS476 (6.7&20) -30ºC to +250ºC +3.5Kpa to -2.5Kpa +3.5Kpa to -1.5Kpa Flex Code Flex Type Diameter Class Air tightness Class Working pressure Max air vel m/s Crushing strength Compressed Uncompressed Isoduct Thermal B C 25 33-10 kg 3-5 kg Sonoduct Acoustic B C 30 33-10 kg 3-5 kg Semiduct Semi-rigid A C 30 100-15 kg 60-10 kg 93 94 | Flat Ducts Plastic Flat Duct Flat Duct 1m Length System 100 Pressure Loss (Pa) Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s DOM010 51300 110 x 54 0.7 1.8 6.3 21.5 SupertubeDOM510 51416 204 x 60 0.2 0.5 1.5 5.2 MegaductDOM910 51476 220 x 90 - - 0.4 1.0 Flat Duct 1.5m Length Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s DOM015 51301 110 x 54 1.2 2.7 9.8 32.2 SupertubeDOM515 System 100 51419 204 x 60 0.3 0.8 2.3 7.8 MegaductDOM915 51477 220 x 90 - - 1.0 1.4 Flat Duct 2m Length Code Duct Size mm @ 15l/s @ 30l/s @ 60l/s System 100 @ 8l/s D1-2000 51490 110 x 54 1.5 3.6 12.6 43 SupertubeD3-2000 51491 204 x 60 0.4 1.0 3.0 10.4 MegaductD4-2000 59435 220 x 90 - - 1.5 2.0 Duct Connector Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s DOM020 51303 110 x 54 - 0.3 1.4 6.3 SupertubeDOM520 System 100 51421 204 x 60 - 0.1 0.4 1.5 MegaductDOM920 51478 220 x 90 - - - - Duct Connector c/w Damper Code Duct Size mm System 100 51304 DOM027 @ 8l/s @ 15l/s @ 30l/s @ 60l/s 110 x 54 16.3 19.9 21.2 - SupertubeDOM527 204 x 60 19.6 21.9 41.1 - MegaductDOM927 220 x 90 - - - - Duct Clip Code Duct Size mm DOM122-4 51325 110 x 54 - - - - SupertubeDOM122-5 51326 204 x 60 - - - - MegaductDOM922 51479 220 x 90 - - - - Horizontal Bend 90° Code Duct Size mm System 100 System 100 @ 8l/s @ 8l/s @ 15l/s @ 15l/s @ 30l/s @ 30l/s @ 60l/s @ 60l/s DOM050 51307 110 x 54 2.6 9.8 39.8 161.9 SupertubeDOM550 51428 204 x 60 0.6 2.1 8.4 33.7 MegaductDOM950 51482 220 x 90 - - - 9.0 Horizontal Bend 45° Code Duct Size mm System 100 53880 110 x 54 DOM055 @ 8l/s @ 15l/s @ 30l/s @ 60l/s - 3.7 15.5 65.8 SupertubeDOM555 54043 204 x 60 - 0.6 2.7 13.2 MegaductDOM955 14098 220 x 90 - - - 4.6 Vertical Bend 90° Code Duct Size mm System 100 DOM060 51308 110 x 54 4.3 15.6 62.8 252.7 SupertubeDOM560 51429 204 x 60 0.7 2.6 10.8 44.3 MegaductDOM960 51486 220 x 90 - - - 7.0 Vertical Bend 45° Code Duct Size mm System 100 53881 110 x 54 DOM075 @ 8l/s @ 8l/s @ 15l/s @ 15l/s @ 30l/s @ 30l/s @ 60l/s @ 60l/s - 2.6 12.7 63 SupertubeDOM575 57570 204 x 60 - 0.6 2.7 13.4 MegaductDOM975 57705 220 x 90 - - - 6.0 Flat Ducts | Plastic Flat Duct Pressure Loss (Pa) Horizontal Tee Piece Code Duct Size mm System 100 DOM080 51313 110 x 54 3.5 11.4 51.3 - SupertubeDOM582 51432 204 x 60 0.9 3.1 12.0 26.4 MegaductDOM982 14194 220 x 90 - - - 12.4 Duct End Cap @ 8l/s @ 15l/s Code Duct Size mm DOM018 51302 110 x 54 - SupertubeDOM518 51420 204 x 60 - Wall Plate - White Code Duct Size mm System 100 System 100 DOM115-4 SupertubeDOM115-5W 51318 MegaductDOM115-6 Flex Duct- White 0.5m Hose 0.5m DOM3305 Hose 0.5m DOM5305 Hose 0.5m DOM9305 Flex Duct Connector System 100 Code 51422 Code @ 8l/s @ 30l/s @ 15l/s @ 8l/s @ 60l/s @ 30l/s @ 15l/s @ 60l/s - - - - @ 30l/s @ 60l/s 110 x 54 - - - - 204 x 60 - - - - 220 x 90 - - - - Duct Size mm Flex Duct- White 3m 110 x 54 Hose 3m 204 x 60 220 x 90 Duct Size mm Code Duct Size mm DOM333 110 x 54 Hose 3m DOM533 204 x 60 Hose 3m DOM933 220 x 90 @ 8l/s @ 15l/s @ 30l/s @ 60l/s DOM381 110 x 54 - - - - SupertubeDOM581 204 x 60 - - - - @ 8l/s @ 15l/s Wall Plate - White Code Duct Size mm System 100 51306 110 x 54 3.6 8.1 33.1 DOM040 @ 30l/s @ 60l/s 136.4 SupertubeDOM540 51424 204 x 60 2.4 6.6 28.4 - MegaductDOM961 51487 220 x 90 - - - 9.0 Duct connector - flex Code Duct Size mm @ 8l/s @ 15l/s Supertube5B303 14193 204 x 60 Adjustable bend Horiz Code Duct Size mm SupertubeDOM545 51427 204 x 60 Fire Wrap Code Duct Size mm Itumescent Sealant 310ml Tube System 100 DOM087 51314 110 x 54 SupertubeDOM587 51433 204 x 60 MegaductDOM987 53375 220 x 90 - @ 8l/s - @ 30l/s @ 60l/s - - - @ 15l/s @ 30l/s @ 60l/s 2.1 6.3 0.7 Code MAS87 95 96 | Circ Plastic Ducts Plastic Round Duct Circ Duct 2m Length Pressure Loss (Pa) Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s @ 60l/s Easipipe 100 1200-4 51321 100 0.1 1.0 2.8 6.2 Easipipe 125 1200-5 51322 125 - 0.4 1.4 3.8 Easipipe 150 1200-6 51323 150 - 0.2 0.8 2.4 Code Duct Size mm @ 30l/s @ 60l/s Duct Connector @ 8l/s @ 15l/s Easipipe 100 DOM493 51401 100 - - - - Easipipe 125 DOM593 51445 125 - - - - Easipipe 150 DOM693 51466 150 - - - - Duct Connector c/w Damper Code Duct Size mm @ 15l/s @ 30l/s @ 60l/s Easipipe 100 DOM494 51402 100 15.2 25.0 Easipipe 125 DOM594 51446 125 10.2 18.3 31.5 61.7 Easipipe 150 DOM694 51467 150 8.4 13.6 23.5 43.6 Code Duct Size mm @ 30l/s @ 60l/s Bend 90° @ 8l/s @ 8l/s @ 15l/s 44.9 101.6 Easipipe 100 DOM490 51383 100 0.9 5.6 21.1 80.1 Easipipe 125 DOM590 51434 125 0.5 2.0 8.4 34.9 Easipipe 150 DOM690 51453 150 0.3 1.0 4.2 18.2 Bend 45° Code Duct Size mm @ 30l/s @ 60l/s Easipipe 100 DOM491 51399 100 0.3 2.1 8.2 31.4 Easipipe 125 DOM591 51443 125 0.2 0.7 2.9 12.2 Code Duct Size mm Tee Piece @ 8l/s @ 8l/s @ 15l/s @ 15l/s @ 30l/s @ 60l/s Easipipe 100 DOM492 51400 100 0.7 2.3 8.5 - Easipipe 125 DOM592 51444 125 0.5 1.8 4.4 - Condensate Trap Code Duct Size mm Easipipe 100 DOM497 51404 100 0.3 1.3 5.9 26.9 Easipipe 125 DOM5697 59433 125 0.3 1.3 5.7 25.0 Easipipe 150 DOM5697 59433 150 0.3 1.3 5.7 25.0 Code Duct Size mm Reducer 125 - 100 40119 150 - 125 50118 125 - 100 150 - 100 Duct Clip @ 8l/s @ 8l/s @ 15l/s @ 15l/s @ 30l/s @ 30l/s @ 60l/s @ 60l/s 0.6 1.5 5.9 150 - 125 0.4 0.6 2.2 8.8 150 - 100 0.4 1.0 3.8 10.0 Code Duct Size mm @ 8l/s @ 15l/s @ 30l/s 24.0 @ 60l/s Easipipe 100 DOM496 51403 100 - - - - Easipipe 125 DOM596 51447 125 - - - - Easipipe 150 DOM696 51469 150 - - - - Fire Break Code Duct Size mm Itumescent Sealant Easipipe 100 DOM488 53376 110 x 54 310ml Tube Easipipe 125 DOM588 59554 204 X 60 Easipipe 150 DOM688 220 x 90 Code MAS87 Flat Ducts | Plastic Adapters Duct Adapters long Code Duct Size mm Easipipe 100 51383 110 x 54 Duct Adapter Short Code Duct Size mm Easipipe 100 51310 110 x 54 Code Duct Size mm DOM490 DD071 Duct Adapter Duct Size 100mm Duct Size 100mm Duct Size @ 15l/s 3.7 @ 15l/s 4.8 @ 15l/s @ 30l/s 14.6 @ 30l/s 20.4 @ 30l/s @ 60l/s 58.0 @ 60l/s 86.2 @ 60l/s Easipipe 125 DD073 51311 204 x 60 100mm 4.1 16.8 68.7 Easipipe 125 DOM570 51430 204 x 60 125mm 0.7 2.9 11.5 Easipipe 150 DOM970 51488 220 x 90 150mm - - 3.7 97 | Flat Ducts Flat ducts, oval, metalsheet Quadroflex - corrugated Quadrofix - smooth interior Internal dimension: System 100 305045 129 x 52 System 151 305046 208 x 52 Rigid, oval installation ducts, smooth interior for air flow, made of galvanized steel band. Fire protection class A1 according to DIN 4102. Temperature resistance: up to +200 °C, length: 3 m Inside connector - tight/tight 85 Corrugated, folded spiral seam pipe made of galvanized steel band for higher vertex pressure resistance. Fire protection class A1 according to DIN 4102. Temperature resistance: up to +200 °C, length: 3 m Dimensions, inside: 305043 129 x 52 3m System 100 305047 129 x 52 15 m / roll System 151 305044 208 x 52 3m External connector - large/large Dimensions: Dimensions: System 100 305007 128 x 51 System 100 (305064) 129 x 52 System 151 305008 207 x 51 System 151 (305009) 208 x 52 Flange collar External connector, stainless steel, to connect two Quadroflex or Quadrofix pipes. Quadroflex - corrugated in a bunch Dimensions: System 100 305010 128 x 51 System 151 305011 207 x 51 Flange collar, stainless steel, for Quadroflex or Quadrofix pipes. ø1 m Internal dimension: 0,5 m 6 to 10 Length System 100 Inside connector, stainless steel, to connect two Quadroflex or Quadrofix pipes. System 100 305047 129 x 52 Corrugated, folded spiral seam pipe made of galvanized steel band for higher vertex pressure resistance. Fire protection class A1 according to DIN 4102. Temperature resistance: up to +200 °C, length: 15 m Duct cover 6 to 10 98 Dimensions: System 100 305055 128 x 51 System 151 305056 207 x 51 Duct cover, stainless steel, for Quadroflex or Quadrofix pipes Flat Ducts | Angle 45° - broadsided Angle 45° - narrow sided Angle 45° (broadsided), made of galvanized steel to bypass Quadroflex or Quadrofix pipes, when little space. External dimensions Angle 45° (narrow sided), stainless steel, to bypass Quadroflex or Quadrofix pipes, when little space. External dimensions System 100 305027 128 x 51 System 100 305029 128 x 51 System 151 305028 207 x 51 System 151 305030 207 x 51 Angle 90° - broadsided, 3 segments Angle 90° - narrow sided, 3 segments Angle 90° (broadsided), stainless steel, in 3 segments to bypass Quadroflex or Quadrofix pipes. Angle 90° (narrow sided), stainless steel, in 3 segments to bypass Quadroflex or Quadrofix pipes. External dimensions External dimensions System 100 305031 128 x 51 System 151 305032 207 x 51 Branch piece - output narrow sided System 100 305033 128 x 51 System 151 305034 207 x 51 Branch piece - output broadsided Branch piece 90°, stainless steel, 3 connection spigots for Quadroflex or Quadrofix pipes. Branch piece 90°, stainless steel, 3 connection spigots for Quadroflex or Quadrofix pipes. Dimensions: Dimensions: SystemNo. Passage Outlet Length 100-100305013 128 x 51 128 x 51 300 100-151305014 128 x 51 207 x 51 360 151-100305015 207 x 51 128 x 51 300 151-151305040 207 x 51 207 x 51 360 SystemNo. Durchgang Abgang Length 151-100305016 207 x 51 128 x 51 220 151-151305048 207 x 51 207 x 51 240 99 100 | Flat Ducts Branch piece - output system 151 Transition - round to flat Transition, symmetric, stainless steel, to adapt oval pipe ends to round sections. Dimensions System Art-no. from to 100 305018 128x51 ø99 151 305019 207x51 ø150 Branch piece 90°, stainless steel, 1 connection spigot for Quadroflex or Quadrofix pipes system 151. Dimensions Passage Art-no. ø150 305017 ø200 303177 Reducer - flat to flat Section reducer, stainless steel, for Quadroflex or Quadrofix pipes Diverter, PVC Dimensions System 151-100 Art-no. 207 x 51 auf 128 x 51 305022 Cutting max. 300 mm! * Stainless steel Angle diverter for disc valve PVC diverter to connect air passages. Dimensions Art-no. System 100 / DN100 311240 System 100 / DN125 311241 System DN151/150 305426* Diverter 90° to connect disc valves. Material: Stainless steel Cold sealing tape Dimensions Cold sealing tape Art-no. H Art-no. System 100/DN100 303052 185,5 305001 System 100/DN125 303053 210,5 Circ Insulated Ducts | ISO+ ducts ISO+ duct, sound and thermal insulation Noise-absorbing, sturdy duct, preferably in unheated areas. Outer sheath made of polyethylene with high density (HDPE); inner sheath made of polyolefin with closed cell structure. Thermal conductivity: 0.040 W/mK at 40 °C. Fire protection class: Outer casing B2, internal duct B1 ISO+ bend 90° Typ DN Art-no. ISO+ B90/160-125 125 311839 ISO+ B90/200-180 180 311845 incl. 1 connector ISO+ bend 45° Typ External-ø Internal-ø Art-no. Length Iso+ D 160-125 160 125 311838 2m Iso+ D 200-180 200 180 311844 2m ISO+ connector Typ Flexible fast clamp made of EPDM. Typ External-ø Internal-ø Art-no. ISO+ C 160-160 160 125 311841 ISO+ C 200-200 200 180 311847 ISO+ transition to Spiral, asymmetric Art-no. ISO+ B45/160-125 125 311840 ISO+ B45/200-180 180 311846 incl. 1 connector ISO+ transition to Spiral, symmetric Material: EPDM Material: EPDM Typ External -ø Internal-ø Art-no. ISO+ R 160-125A 160 125 311843 ISO+ R 200-180* 200 150 311848 * for Spiral160 DN Typ External-ø Internal-ø Art-no. ISO+ R 160-125 160 125 311842 ISO+ R 200-180 200 180 311848 ISO+ R 200-160 200 150/160 311849 ISO+ FSMQC Quick clamp To fix rubber collars for Spiral duct. Type Dia for Spiral duct Art-no. 60mm-165mm 160 51624 60mm-215mm 200 51625 101 102 | Silencer Silencer LF, connection silencer, flexible Perforated aluminium flex pipe inside, PVC cover outside Sound insulation made of 25 mm mineral wool. Connection sleeve on one side, connection fitting on the other side. Length: 800 mm Insertion losses in dB Octave centre frequency in Hz DNArt-no. Connecting sleeve DN 125 250 500 1k 2k 4k 8k tot 10012436 ø100 100 8 14 22 30 25 10 8 15 12512533 ø125 125 6 12 22 28 25 11 9 14 SCD, silencer, flexible The internal duct consists of a closed, non-woven internal hose (washable) and an insulation layer made of glass wool with a thickness of 25 mm and sound reducing and thermal effective properties. The outer casing is made of glass-fibre reinforced, tear-resistant aluminium laminate. Fire classification outer casing: Ex.1. Length: 1,2 m Noise reduction, non-woven insulation 25 mm Art-no. Name D (mm) L (m) 2554 SCD 80 80 2555 SCD 100 2556 SCD 125 Mid frequency band. Hz 63 125 250 500 1000 2000 4000 8000 Tot (dB) 1.2 13.6 22.4 40.2 38.7 36.5 41.3 51.6 45.8 39 100 1.2 15.9 22.9 31.1 38.6 36.4 40.6 50.1 35.9 39 125 1.2 11.7 18.9 32.4 29.9 28.8 34.5 40.9 24.5 32 2557 SCD 150 150 1.2 12.2 10.9 29.7 30.1 29 38.3 34.6 20.4 32 2558 SCD 160 160 1.2 19.3 25.4 30.5 27.1 23.8 32.2 27.8 17.3 28 2560 SCD 200 200 1.2 10.7 12.1 28.7 22.8 22.8 30.6 19.4 11.9 26 2561 SCD 250 250 1.2 12.9 18.7 24.3 19.5 19.9 27.7 12.9 10.2 22 2562 SCD 315 315 1.2 16.6 23.2 18 15.2 16.5 19.6 10.1 8.5 17 TSD, semi rigid silencer, flexible Art-No The semi flexible sound attenuator consists of a corrugated perforated aluminium innerduct and a 2 layer corrugated outerduct with end spigots made of aluminium. The space between the inner and outer duct is filled with 50mm sound absorbing material. LDC, silencer, rigid Easily-fitted silencer for circular ducts, fitted with a connection that complies with the spiral duct standard. The LDC effectively reduces noise in the duct. For the most effective noise reduction, the silencer should be fitted immediately behind a fan or bend. The silencer is delivered with two separate spigots. Insulation thickness 100 mm. 1000 mm L 54144 TSD-B100/1 Flex Silencer 54145 TSD-B125/1 Flex Silencer 54146 TSD-B150/1 Flex Silencer 54147 TSD-B200/1 Flex Silencer 54148 TSD-B250/1 Flex Silencer 54149 TSD-B315/1 Flex Silencer Art-No 600mm L Art-No 900mm L 5188 LDC 100-600 5189 LDC 100-900 5190 LDC 125-600 5191 LDC 125-900 5199 LDC 150-600 - - 5192 LDC 160-600 5193 LDC 160-900 5194 LDC 200-600 5195 LDC 200-900 51200 LDC250-600 5196 LDC 250-900 5949 LDC315-600 5197 LDC 315-900 Silencer | Duct Silencer, flexible Perforated aluminium flex pipe inside, PVC cover outside Sound insulation made of 25 mm mineral wool. Length: 1 m DNArt-no. Connecting sleeve 10012491 ø100 12512492 ø125 16012493 20012494 Insertion losses in dB Octave centre frequency in Hz DN 125 250 500 1k 2k 4k 8k tot ø160 100 15 31 31 32 ø200 125 26 36 30 31 29 13 11 24 28 14 11 24 160 17 31 25 27 18 200 15 29 22 23 18 8 8 19 8 7 18 Flat duct Silencer, flexible Silencer for noise reduction Oval duct connection made of aluminium. Absorption material: mineral fibre-free. Fire protection class A1 according to DIN 4102. Temperature resistance from -60 °C to +150 °C LengthArt-no. Dimensions inside 500305012 129 x 52 Dimensions outside 202x117 Insertion losses in dB Octave centre frequency in Hz End connections System 125 250 500 1k 2k 4k 8k tot 128 x 51 100 8 10 18 46 50 44 38 15 Flat duct Silencer, rigid 0 36 60 System 100 Mineral fibre-free silencer in combination with Quadro System 100. Fire protection class A1 according to DIN 4102. Temperature resistance: up to +200 °C Insertion losses in dB Octave centre frequency in Hz 58,5 500 LengthArt-no. Dimensions End connections 500305036 360 x 60 128 x 51 Inside duct silencer DN 125 250 500 1k 2k 4k 8k tot 100 18 14 13 11 19 18 17 13 Inside duct silencer, made of fire and mould protected foam material according to the requirements of emission class M1 (melamine resin). Complete valve function for sound insulation and pressure control. Insertion losses in dB Octave centre frequency in Hz d1 s = IRS Stärke DN Art-no. d s 100305049 102 50 DN 125 250 500 1k 2k 4k 8k tot 100 14 12 8 7 7 11 18 8 125305050 127 50 125 14 9 5 8 6 11 16 7 160305051 162 50 160 14 9 8 7 7 14 17 8 200305193 202 50 200 12 4 4 8 8 13 14 6 103 | ISO+ Ducts Fresh and exhaust air grille Fresh and exhaust air hood Kombi grille CVVX Kombi grille for separate flow of fresh and exhaust air. Made of coated steel sheet, colour anthracite. Sizes 160/200 are also available in colour white. 15° H h E A ød1 B The hood can be used for fresh or exhaust air. Made of galvanized steel sheet. The internal protective grille protects from rain, leaves etc. DN Art-no. 200305042 ød1 øD h H kg 200 360 100 197 1,9 øD øD C CVVX black Art-no. white Art-no. A B C øD E 160 5563 12453 420 362 215 160 130 200 5564 12593 500 402 255 200 133 250 8498 - 680 550 350 250 136 Roof ventilation hood for fresh and exhaust air ⌀D Fresh and exhaust air grille IGC ⌀d 104 Fresh and exhaust air grille, made of aluminium pressure die casting with wire grille. IGCArt-no. Roof ventilation hood with pipe bracket. Other roof pitchs on request. DN Art-no. ød1 ød2 L L1 L2 L3 1256788 210 125 830 480 350 130 1606789 180 420 820 260 158 178 20067893 on request ød øD 1005581 100 125 1255582 125 150 1605583 160 185 2005584 200 225 2505585 250 275 Terminals | External Weather Louvre Inlet-/blow-out nozzle 270 70 Ideal for use on the external walls of a building for intake or extract air, the 45 deg blades are fixed at 50mm centres and have excellent integral rain defence features. Constructed from extruded aluminium sections, frames are fully welded and fitted with a bird guard as standard. Standard finish is satin anodised. with other colours available on request. Free area approx 50%. Any size can be made to suit your requirements. 45° 200 Made of mirror-bright stainless steel, for outside and extract air, with bird-protection grille. DNArt-no. Connection 150305035 ø150 200- ø200 VK-SR, air grill for spiro ducts Universal Roof Cowl C F G Universal Roof cowl, complete with lead flashing and multi cut off spigot 100mm, 110mm, 125mm, 150mm & 160mm Dia cut offs B Fresh air and exhaust air grill. The duct connection fits directly into duct with diameter 160, 200 and 250. Material: steel, powder coated (black) E D A DNArt-no. EFS-RCK53842- SizeNo. A B C D E øF G 160 312507 326 306 280 149 137 160 33° 200 312508 326 306 280 149 137 200 33° 250 312509 326 306 280 149 137 250 33° D E A SizeArt-no. A B C D E øF G ISO+ grille 125 312506 252 262 239 130 on request 125 35° ISO+ grille 180 304635 252 262 239 130 41 180 35° B C G Fresh air and exhaust air grille. The duct connection fits directly into ISO+ duct with diameter 125 (Iso+ D160) or 180 mm (Iso+ D200). Material: steel, powder coated (black) øF ISO+ grille 105 106 | Diffusers Diffusers Elegant - Supply diffuser VS VT VT AT, VE B AT D C VI, VS Description Systemair Elegant supply diffuser for wall mounting, with a perforated front plate and guide jet opening (VI and VS). The VS version also has a removable damper with test points. Function The Elegant has been especially developed for providing a draught-free air supply from the rear walls of offices, hotel rooms etc. The VI or VS version with guide jet is recommended for cooled air. The guide jet prevents the air stream from falling into the occupied zone before it has reached an acceptable temperature. Max. temperature difference dT 10 K is permissible. The Elegant is also suitable for VAV systems, as the distribution pattern is maintained across the entire flow area. Design The Elegant is manufactured from steel Elegant AT 100 125 VE 100 125 160 VI 125 160 VS 125 160 VT 100 Art-No. 6920 6973 6298 6827 6828 6829 6830 6831 6832 6202 6207 Max. air volume [m³/h] 30 60 30 60 140 70 150 60 140 30 60 125 øA 98 123 98 123 158 123 158 123 158 - - øB 165 165 165 165 198 165 198 165 198 165 165 C 111 115 111 115 124 115 124 240 274 59,3 59,3 D 87 89 87 89 86 89 86 214 236 33,2 33,2 and consists of a convex front plate with perforations and guide jet opening. The front plate is finished in the standard white powdercoating (RAL 9010-80). EFF Ceiling- and wall diffuser Description Systemair EFF exhaust diffuser for installation on ceiling or wall with lockable settings. Function The EFF is an exhaust diffuser for installation on ceiling or wall. It can also be used for supply air. The diffuser has a lockable central cone which is rotated to adjust the pressure and consequently the air volume. Fire Rated Versions available. EFF 100 125 150 160 Art-No. 6146 6147 7490 6148 Max. air volume [m³/h] 20 50 100 100 øA 100 125 149 159 øB 135 160 191 196 C 15 15 15 15 Design The EFF is manufactured from sheet steel with a white powder-coated finish (RAL 9010-80). Diffusers | Balance-E Plastic Extract diffuser Description Systemair Balance-E exhaust diffuser for installation on ceiling or wall with lockable settings. Function The Balance-E is a round exhaust diffuser with an aerodynamically shaped valve frame cone. The Balance-E performs extremely well with regard to sound level, pressure drop and air flow characteristics. The Balance-E is installed in a frame or directly into the duct. Balance-S Plastic Supply diffuser frame Description Systemair Balance-S supply diffuser for installation on ceiling or wall. Function The Balance-S is a round supply-air diffuser with an aerodynamically shaped valve cone. The Balance-S performs extremely well with regard to sound level, pressure drop, air flow and self-damping. The Balance-S is installed in a frame or directly into the duct. Balance-E 100 125 160 Art-No. 6961 6962 6963 Max. air volume [m³/h] 20 50 100 øA 100 125 160 øB 70 87 118 øC 142 160 195 D 61 61 57 Design The Balance-E is manufactured from recyclable polypropylene and tolerates temperatures up to 100°C. This material also withstands most chemicals in small concentrations. Polyether packing. The Balance-E is supplied in a white finish which matches RAL 9010-80. Balance-S 100 125 160 Art-No. 6965 6966 6967 Max. air volume [m³/h] 20 50 100 øA 100 125 160 øB 81 104 120 øC 156 182 206 D 72 78 86 Design The Balance-S is manufactured from recyclable polypropylene and tolerates temperatures up to 100°C. The Balance-S is supplied in a white finish which matches RAL 9010. Stainless Steel Air Valves Function The EFF is an exhaust diffuser for installation on ceiling or wall. It can also be used for supply air. The diffuser has a lockable central cone which is rotated to adjust the pressure and consequently the air volume. Description Systemair FSSSVLF exhaust diffuser for installation on ceiling or wall with lockable settings. Design The FSSSVLF is manufactured from stainless steel with a brushed finish FSSSVLF 100 150 160 Art-No. 51634 53981 51635 Max. air volume [m³/h] 20 100 100 107 108 | Diffusers TFF Ceiling and wall diffuser Description The Systemair TFF circular supply diffuser. This diffuser has a shielding device for producing a directional (180°) distribution pattern and has an adjustable gap. Function The TFF is a circular supply diffuser for ceiling installation. The TFF consists of an inlet cone and diffuser unit containing sound-absorbent material. The technical specifications of the diffuser unit give it a wide range of applications. By rotating diffuser unit, the throw and pressure drop can be adjusted steplessly. Both concentric and eccentric distribution patterns can be selected by using the shielding TFF 100 125 150 160 Art-No. 6090 6091 7509 6092 Max. air volume 20 [m³/h] 50 100 100 øA 100 125 149 159 øB 135 160 191 196 C 15 15 15 15 device provided. Design The TFF is manufactured from sheet steel with a white powder-coated finish (RAL 9010-80). TST Supply diffuser Description The Systemair TST circular supply diffuser. The distribution pattern can be altered and the gap width is adjustable. Function The TST is a circular supply diffuser for ceiling installation. The two-part diffuser unit can be adjusted to provide the desired throw. A shielding device is included which can be used to alter the distribution pattern to a directional (180°) pattern. Design The TST is manufactured from galvanized sheet metal, with a white powder-coated finish (RAL 9010-80). BOREA TST 100 Art-No. 125+ 160+ 6105 6106 6107 Max. air volume [m³/h] 30 60 140 A - 320 360 B - 250 250 C - 150 160 D - 47 47 E - 185 210 F - 116 121 G - 191 201 H 30-50 30-50 30-50 RI 80 105 105 J 199 249 249 K 99 124 159 D1 - 99 124 D2 - 127 162 øL* 107 132 167 PER 100-125 PER 125-160 * hole dim. Description The Borea valve is adjustable and can be used for supply and exhaust air. The valve can be installed in ceilings and walls. Function The outlet can be partly closed for an individual regulation of supply air flow. Design Borea is completely made of polystyrene. It consists of a main casting, a plate closer and adjustable front grid. Therefore, different flow forms and routes can easily be adjusted. They can be inserted into DN125 pipes or DN125 flange collars. Self regulating extract air valves | BOREA settings Supply air Grid open/plate closed Grid closed/plate in position 1 without shielding Grid closed/plate in position 2 with or without shielding Grid open/plate in position 2 without shielding Grid closed/plate in position 1 without shielding Grid closed/plate in position 2 without shielding Exhaust air The plate inlet can be partly closed by deflectors to shield some areas. Deflectors can be removed for exhaust or 4-sided outlet. Open (+) and closed (-) grid Hmin. Dimensions + Hmax. - ØD1 Open (+) and closed (-) valve plate (position closed, 1 and 2) ØD2 + BOREA Art-no. 125 ØD1 ØD1 119 165 - Hmin. Hmax. 12 24 Deflectors Technical data Type Air volume Qv[m³/h] Supply air Grid open, Valve closed dB (Pa) BOREA 125 Lw (dB(A) Exhaust air without deflector with deflector Grid open, Valve open Grid closed, Valve open Grid closed, valve open Position 1 Position 2 Position 2 Position 2 Position 1 Position 2 dB (Pa) dB (Pa) dB (Pa) dB (Pa) dB (Pa) dB (Pa) Lw (dB(A) Lw (dB(A) Lw (dB(A) Lw (dB(A) Lw (dB(A) Lw (dB(A) 45 9 < 20 18 26 7 < 20 13 22 3 < 20 20 23 7 < 20 60 17 < 20 30 31 13 21 20 27 5 < 20 37 33 13 21 75 25 24 40 35 18 24 31 32 8 < 20 57 41 20 25 90 36 31 56 39 25 28 43 36 11 20 80 46 27 29 120 62 43 - - 40 36 70 43 19 28 - - 48 36 150 - - - - 62 41 - - 28 34 - - 74 43 109 | Self regulating extract air valves Self regulating extract air valves AE Self regulating motorized valve 4 3 AE No. 15/30 31412 30/60 31413 45/120 31414 5 1 2 Model Produced in white polystyrene (standard), the AE air valve, installed in WC room and baths, provides a flow of extraction determined. Operation The regulator consists of a rigid component and ensures a determined air flow of extraction within a range of pressure between 50 and 160 Pascals. Principals The extract is always on tension thanks to a connection normally switched off.An impulse on the switch creates a power cut which opens the extract to its maximumflow (opening time: around 40 seconds). The 230 V supply of the extract is provided by two wires (2 x 1.5 mm²) to be connected,going out by the back of the support plate (see drawing). This must have a protectiondevice clearly identified on the electric board - class II electric appliance -.After taking out the casing vent (2), unscrew the box (5). The wires go through a cableat the back of the Ceiling mounting Ceiling mounting, the unit can be fixed on the ceiling using a three-claw plasterboard sleeve or a 125 Ø plastic sleeve for penetrating slabs. A ceiling mounting needs the using of a return angle guide for the concerned models. Removable louver grill Casing vent Support plate with sleeve and rubber ring Control module Electric connection box Ø125 155 three-claw plasterboard sleeve Ø 125 Ø125 Maintenance The Extract AE must be periodically cleaned (at least twice a year) in order to keep their entire efficiency. Cleaning procedure: • Remove the casing vent (2) of the plate (3) and remove the flap (4).• The plate (3) linked to the duct must not be touched. The elements on it do not need any cleaning.• Clean the casing vent (2), the grill (1) and the control module (4) with soapy water then rince.• Fix back the control momule (4)• Fix back the casing part (2) on the plate (3) 1. 2. 3. 4. 5. 100 plate and linked to the connection box. The support-plate of the extract must be screwed on the wall.On the first stand-by mode, the AE valve will normally extract the maximum air-flow. 275 plastic sleeve for penetrating slabs Ø125 48 Function Intended to equip the facilities housing MEV, housing and local service, the range of the AE extraction air valves self meets the regulatory requirements while combining aesthetics and technology. Reliability mechanical, proven functionality, performance ventilation and noise are the major assets of all AE air valves series. The AE air valves meets the habitat requirements of the NF MEV. Single or double speed, both models perfectly consistent allow a uniform architectural treatment between kitchen, bathroom and WC. 17 return angle guide Acoustic characteristics LW dB(A) AE 70 Pa 100 Pa 130 Pa 160 Pa 15/30 24 27 30 33 30/60 25 31 34 36 45/120 27 33 34 37 200 120 150 Airflow in m³/h 110 100 60 45 50 0 30 15 40 60 80 100 120 140 160 Pa ∆pt Self regulating extract air valves | AL Self regulating valve Operation The regulator consists of a rigid component and ensures a determined air flow 35028 30 35029 45 35030 60 35031 75 35032 90 35033 120 35034 150 35035 of extraction within a range of pressure between 50 and 160 Pascals. Maintenance To maintain maximum efficiency, it is necessary to conduct a periodic cleaning: • Remove the grille (4) and regulator (3) the body of the valve (removed from the sleeve if necessary). Airflow in m³/h Possible fitting with Ø 99, 116, 150 or 160 mm. When ceiling mounted, an adapted sleeve can be used (125 Ø, 3-claw plasterboard sleeve, or 125 Ø plastic sleeve for penetrating slabs for use with the 125 Ø sleeve). • The sleeve (1) shall not be detached from the duct. • Clean all either in the upper part of a dishwasher, either manually with soap and water, nothing disassemble the regulator. • Walk up the valve. Installation The AL is installed in vertical walls by simple fitting onto a 125 Ø sleeve fixed on the aeration duct. The lip seal ensures that the sleeve is securely fixed and watertight. Ø125 155 3-Claw plasterboard sleeve Acoustic characteristics Ventilation characteristics 1. Collar Ø 125 with lip seal (delivered separately). 2. Body of the valve. 3. Regulator. 4. Removable grille. LW dB(A) AL 70 Pa 100 Pa 130 Pa 160 Pa 15 m³/h 19 27 31 34 30 m³/h 27 30 33 36 45 m³/h 27 33 34 37 Ø125 Model Produced in white polystyrene(standard), the AL air valve, installed in WC room and baths, provides a flow of extraction determined. Art-No. 15 100 Function Intended to equip the facilities housing MEV, housing and local service, the range of the AL extraction air valves self meets the regulatory requirements while combining aesthetics and technology. Design fluid grid in several colors, reliability mechanical, proven functionality, performance ventilation and noise are the major assets of all AL air valves series. The AL air valves meets the residential requirements of the NF MEV. Single or double speed, both models perfectly consistent allow a uniform architectural treatment between kitchen, bathroom and WC. AL 275 Slab penetration sleeve (Polystyrene) AL Pressure drop in PA 111 | Self regulating extract air valves BHC Motorized valve 174 169 33 Type Art-No. BHC-100 7178 Transformer-12 V 7387 Inlet adapter ø100-125 7484 16 25 46 Function BHC 100 is a motorized damper with integrated motion (PIR) and humidity sensor for bathroom installations. The extract units may be installed either on the wall (in a vertical or horizontal position), or the ceiling. The humidity and the motion sensors work independently of each other. The damper opens whenever motion is indicated and closes 25 min after the last indication. The humidity sensor controls the fully modulating damper from RH 30% to 75%. The movement sensor is dependent on a power supply and the BHC uses either a 9V battery or 12V AC. The humidity sensors will open the damper regardless of a power supply. Ø80 mm (with special sleeve Ø80 mm). note: the BPD is delivered with adapter Ø100 mm. The BPD dampers are especially useful in constant pressure systems for example block of flats. Accessories 100/125 inlet adapter and 12/9 v transformer. Airflow/Pressure Chart Enables to adapt the fixed shutter position. Supplied on installation instruction) More Standard and better longevity: 2 x 1.5 Volts AAA LR03 Batteries. Buzzer: Enables to inform the occupant when the battery needs to be replaced (i.e. when the battery level is below 2.2V). This buzzer rings when the presence sensor or the switch is activated. Possibility to connect a dedicated “CAL” for 12VAC supply. Spigot Versions Ø100 mm and Ø125 mm (with adapter). Airflow in m³/h @ 100 Pa Airflow in m³/h Nominal pressure in Pa 112 Measured pressure in Pa Relative humidity in % BHC h..(airflow <<+>> at min. setting) BHC h..(airflow <<+>> at max. setting) Data given on ⌀100 mm Self regulating fresh air valves | Self regulating fresh air valves FAV sound insulated wall diffuser supply diffuser outside grille wall spacer sound insulated with storm protection 90 80 FAV 70 60 50 Referenz Type Art-No. FAV 312214 (set) øBore (core drill) max. air volume with standard filter G3 Noise level Dn.w * wall thickness Rw, R ** 125 mm (132 mm) 10 Pa 30 m³/h 400 mm / 48 dB 500 mm / 51 dB 18 dB 20 dB * Weighted element standardised sound level difference Dn.w according to DIN EN ISO 140-10 ** Sound insulation value according to DIN 4109 *** Colour white: similar to RAL 9010 Version/ Colour *** PVC, square, white 5000 3150 2000 800 [ Hz ] 1250 500 315 200 80 30 125 40 50 Application / installation possibilities For installation in facades as wall diffuser for fresh air supply in single-family houses, office buildings and multi-storey residential buildings. The wall diffuser is particularly suitable in living rooms and bedrooms. Function Used air from kitchens, bathrooms, lumber-rooms and toilet rooms is exhausted via an exhaust system. Fresh air is filtered by the FAV and well distributed into living rooms, bedrooms, children rooms and lounges. Stepless adjustable volume flow via iris damper. An optimal efficiency can be achieved by an installation position on the upper wall next to windows, in a height of 2.0-2.2 m above a radiator. A storm protection limits supply air to 30 m³/h and avoids draught. [ dB ] The FAV wall diffuser impresses with its design and outstanding sound insulation properties. The new designed intake valve is suitable for normal and high sound insulation requirements by its excellent functions and air distribution characteristics. All necessary components for the installation are available as a complete package. 113 | Self regulating fresh air valves Accessories FAV Outdoor grille Raincover for outdoor grille Art-no. Colour Art-no. Colour Outdoor grille 312217 white, RAL 9010 Raincover 312216 white, RAL 9010 Filter cartridge F7 Standard filter mat Art-no. Art-no. Length Standard filter 312218 Filter F7 312215 94 mm VTK Self-adjusting fresh air vent This self-adjusting fresh air vent has a temperature-sensitive thermostat bulb which regulates the vent plate, adjusting the air gap and air flow according to the outside temperature. When it is set to ‘automatic’ the valve disc reduces the air supply when the outside temperature falls, and increases the flow when the outside temperature rises. ⌀C B ⌀A ⌀D 150 140 114 Spacers for maintaining minimum air flow are available as an accessory. Supplied complete with a thermostat bulb for temperatures between -5 and +10°C, plus a wall duct and external grille. VTK 100 160 Art-no. 5658 5659 øA 95 157 B 40 47 øC 147 207 øD 104 163 Constant flow Regulators | Air volume controller RDA Constant volume damper D1 1 D2 2 L Function The air flow regulator RDA is an element placed inside the duct in order to obtain a constant flow within a pressure range from 50 to 200 Pascal. It is used in ventilation or air conditioning systems for supply or return air. The air is forced to pass through predetermined space in which a flap can change the position according to the specified air flow. The flap is attached on to a calibrated spring and therefore no auxiliary power is needed. 3 D1 35259 80 / 30 (m³/h) 35260 80 / 45 (m³/h) 35261 80 / 50 (m³/h) 35262 80 / 60 (m³/h) 35263 100 / 15 (m³/h) 35265 100 / 30 (m³/h) 35266 100 / 45 (m³/h) 35267 100 / 50 (m³/h) 35268 100 / 60 (m³/h) 35269 100 / 75 (m³/h) 35270 100 / 90 (m³/h) 35271 100 / 100 (m³/h) 35272 125 / 15 (m³/h) 35274 125 / 180 (m³/h) 35280 125 / 30 (m³/h) 35275 2 125 / 45 (m³/h) 35276 125 / 50 (m³/h) 35277 125 / 60 (m³/h) 35214 125 / 75 (m³/h) 35213 125 / 90 (m³/h) 35212 125 / 100 (m³/h) 35278 125 / 120 (m³/h) 35211 125 / 150 (m³/h) 35279 3 Design RDA is made from plastic material (polystyrene) classified M1 in grey colour. Maximum temperature is 60°C. spacer *spacer = special body without spacers 1* air flow = special shims with air flow ref. RDA 80 100 125 L 55 60 90 øD1 117 96 120 øD2 73 120 117 Flow regulators are characterized by their noise level in dB(A). Lw in dB(A) Flow (m³/h) 50 Pa 100 Pa 150 Pa 200 Pa 15 25 29 32 35 30 26 31 35 38 45 27 33 36 39 60 32 37 39 42 75 32 37 40 42 90 32 38 41 44 120 30 34 39 42 150 33 37 41 45 Tests reports : CETIAT 2315002 for air flow RD Ø80 to RD Ø125 mm Air flow in m3/h Mounting RDA is inserted directly into a horizontal or vertical circular duct. It is fixed and kept airtight by a lip seal. Arrow indicates the airflow. If the unit is placed in supply duct, the space between the diffuser and the unit must be at least 3x diameter of the duct. If used for return air the space must be 1x diameter of the duct. Art-No. 80 /15 (m³/h) D2 1 L RDA ∆PT, Differential pressure in Pa Airflow LW dB(A) (m³/h) 50Pa 100Pa 150Pa 200Pa 15 25 29 32 35 30 26 31 35 38 45 27 33 36 39 60 32 37 39 42 75 32 37 40 42 90 32 38 41 44 120 30 34 39 42 150 33 37 41 45 180 34 40 44 47 210 34 40 42 44 240 35 41 44 47 270 37 43 45 49 300 33 37 42 45 115 116 | Air volume controllers SPI Iris damper Function The SPI is an iris damper for measuring and adjusting the air flow. The SPI has the following specifications: low noise level, centrically formed air flow and fixed test points for precise measurements. The damper also has an adjustment aperture which can be opened completely, which means there is no need for an access door for cleaning. Available in sizes Ø80-800. Max temperature for SPI is 70°C. Design The damper is manufactured from galvanised sheet steel and is fitted with a rubber seal tested for air-tightness. Mounting The SPI adjustment damper must be installed in accordance with the distances required to minimise air-flow deviation. The SPI enables the taking of precise airflow measurements at all points including points close to duct deviations such as T junctions and bends, and points in front of other supply-air devices (see below). Protective distance before bends 1 X ØD after“ 1 X ØD before T-pipes 3 X ØD after “ 1 X ØD before supply-air devices 3 X ØD Ordering code The ordering code is SPI - 160 with sizes. Tune-R Single Blade Damper SPI Art-no. Ød C ØD 80 7621 79 110 125 100 6750 99 54 163 125 6751 124 63 210 150 6752 149 54 230 160 6753 159 60 230 200 6754 199 62 285 250 6755 249 62 333 300 6756 299 65 405 315 6757 314 63 406 400 6758 399 70 560 500 7625 499 60 644 630 7626 629 60 811 800 6881 798 70 1015 TUNE-R Size 80 - 630 mm A1 C1 Tightness class C4 24V spring actuator H M0 M1 M2 M3 M4 M5 Version 24V, 0-10V stepless spring actuator M6 Stainless steel for usage in the food industry (Optional) for general usage handle preparation for actuator 230V actuator 24V actuator 24V, 0-10V stepless actuator 230V spring actuator Function Tune-R is a control and shut off damper for round ducts. It is available in various versions with blade tightness class 1 or 4 and casing tightness class A or C tested according to EN 1751. A1 version is ideal in simple installations for regulating the air volume in circular ducts. C1 version is required for duct installation with airtight requirements towards the outside of the duct or to minimize the leakage towards the outside surroundings. It can also be used as a shut off damper for air handling units, combined with a spring return actuator. In case of power outage the damper can maintain a fully closed position. The damper’s special construction allows external insulation up to 50 mm. The damper can be supplied in a manual or 1 2 3 A-304 A-316 motorized version with an integrated position indicator. Design The damper is manufactured from a galvanized steel sheet and is silicone-free. All the gaskets are manufactured from black rubber. Plastic bushings are from a PPO material. All the materials are flame retardant. Fire Dampers | 117 PKI-C Cartridge Fire Dampers Fire resistance class EI60S, EI90S and EI120S Cartridge fire dampers are designed and have CE mark in accordance with EN 15650 and certified to comply with the EI-S (EN 1366-2) performance attributes. PKI-C fire dampers are designed to be embedded into fire partition walls, or at the end of a duct in front of the valve. Installation of these devices is described in the Installation, Operation and Maintenance of the Cartridge Fire Dampers manual. As a standard, all the dampers are supplied in a basic version, with a microswitch, or accessories - cover plates . The fire damper automatically sets itself to a „CLOSE“ position if the thermal fuse link gets ruptured. After the closure, the damper blade is mechanically secured in the closed position and can only be opened manually, which requires access of the maintenance staff into the duct. To improve the duct accessibility for fire damper inspection purposes, we supply a flexible coupling as an accessory - labelled as TVKC in the Ordering Codes section. The thermal fuse link releases the coupling mechanism when the air temperature in the damper exceeds 72°C. Main Dimensions and Weight d EI60/90/120S (mm) W1 (mm) Ød ND (mm) 27 0,3 0,3 125 39,5 0,4 0,4 47 0,5 0,5 52 0,4 0,6 160 57 0,5 0,6 180 67 0,6 0,7 200 77 0,7 0,9 150 W1 EI90/120S M (kg) 100 140 60 EI60S ND-1,5 Ceiling Installation 1 1.ceiling 2 2.duct 3 4 3.gypsum / mortar / concrete 5 4.PKI-C D D – installation into continuous ducts E – installation with a circ Air valve. Installation Into the End of a Duct with a Valve It is possible to install the cartridge fire damper at the end of a duct in a wall / ceiling with a valve orifice E 5.Air valve 118 | Geothermal heat exchanger GEO Geothermal heat exchanger unit Example of installation GEO Why choose a ground heat exchanger? In the winter, domestic heat recovery units switch to a frost protection mode at low temperatures outside. This usually means that the supply fan slows down, causing an imbalance between the supply and exhaust air through the heat recovery unit. Another possibility is that a (pre-) heater is turned on, which usually consumes 1 to 2kW of energy. In the summer, at high external temperatures, the supply air from outside can be warmer than the air inside the house. Thus, this warm supply air can heat the house while this is not preferable. The horizontal ground heat exchanger GEO can offer a solution for the problems mentioned above, using a minimum of energy. Why choose a GEO? GEO has its own control which can be used in combination with any type of heat recovery unit. This control will start the highly energyefficient pump of the GEO at specific set outside temperatures, causing the liquid to flow through the duct. The temperature of the liquid, will approach the temperature of the soil and will transfer its energy to the supply air of the heat recovery system through the battery of the GEO. By using GEO, the efficiency of the heat recovery can be increased. Items Art-no. GEO Unit, including G4-Filter, 312513 Pipe, ND 12,5Bar 304981 Heat Exchanger Liquid (-14 °C) 304989 Benefits • With 8W energy, you can gain up to 1.5 kW; • Can be used in combination with any HR-unit up to 500m³/h; • Increases the efficiency of the heat recovery unit; • Has its own control, allowing energy con- sumption only when needed; • Has an A label-EC pump and a G4 filter for the protection of the heat exchanger; • Is easy to install, all in 1 case (pump, control, sensors, filters, filling and venting unit, battery, gauge, vent valve, volume meter, and pressure vessel); • Has a right / left version in 1 unit and the air to the heat recovery unit can be mounted both on the top and on the side; • Thanks to relatively thin duct (25 mm), it is easy to install; Dimensions • Is an hygienic and attractive solution; • Is easy to clean: condensation develops in the Aquacom, which is led to the sewer through the condensate drain. Geothermal heat exchanger | Pressure loss GEO 100 90 80 Pa 70 60 50 40 30 20 10 0 0 100 200 300 400 500 600 700 Q m³/h T GEO - „T in“ is constant 35 30 25 T °C 20 15 30°C in 10 T out summer T out winter 5 -10°C in 0 -5 0 100 200 300 400 500 -10 -15 Q m³/h Above is valid with a glycol/water supply temperature of 10°C. For example: In an average house with the Heat recovery unit at speed 2 (+/- 250m³/h) in summer the GEO will cool down the outside temperature from 30°C to 20°C. In winter the GEO will heat up the outside temperature from -10°C to 2,5°C. 600 119 120 | Vacuum cleaner V20/V30 Vacuum Cleaner • Sturdy PVC housing • Appealing design • Excellent suction power • Easy, flexible installation • Easy operation and maintenance • Long service life Basic equipment Hose set with on/off switch at the handle (11 m) Art-No. 12550 The central vacuum cleaner V20/V30 is a powerful, low-noise unit. Motor cooling via separate fresh air duct system to avoid soiling. The central cleaner is connected and switched to inlet valves via low voltage wire. The dust canister is situated inside the top of the device. Dust is separated by the filter bag. Our vacuum cleaners are equipped with safety filters and filter barriers to optimise dust separation. Complete pipe kit including all needed pipe parts, glue, pipe clips, control cable and installation Manual. Available in 3 sizes: for 1, 2 or 3 inlet valves. Vacuum cleaner | Accessories vacuum cleaner Silencer for exhaust air Art-No. Wall grid for exhaust air Art-No. 3744 Vacuum socket Wall vacuum socket Art-No. 3745 Hepafilter 12315 Ash separator Single vacuum point with PVC mounting frame, white Art-No. 8485 Art-No. Premium parquet brush with roller 12549 Art-No. Premium turbo brush 12320 Basket for accessories Extra large brush for hard floors. Art-No. 308685 Art-No. V20 V30 Type Art-No. Power output (max.) Motor cooling Voltage 12547 1 600 W Environment 230 V (50 Hz) Control circuit 24 V 24 V Suction effect Current Delay fuse Low pressure (max.) Air flow Noise level LpA (1m) Vacuum unit container Mass Gewicht Max. pipe length* Pipe diameter 540 W 6,3 A 10 A 2 730 mmWs 50 l/s 68 dB(A) 31 l 23 l, single-use approx. 7,4 kg approx. 30 m Ø 50,8 mm (2”) ~2,5 m cable (incl. plug) 620 W 6,5 A 10 A 2 880 mmWs 57 l/s 67 dB(A) 31 l 23 l, single-use approx. 7,9 kg approx. 30 m Ø 50,8 mm (2”) ~2,5 m cable (incl. plug) Cable length 12548 1 650 W Environment 230 V (50 Hz) * Pipe length between the appliance and the farthest vacuum point, inclusive exhaust air hose. The exhaust air hose should not exceed a length of 10 m. The maximum hose length has been calculated by using a hose set of 10 m. 14508 Art-No. Contents duct kit Art-No. Bend 90° for connection vacuum point Elbow 90° (one piece swivel-mounted) Elbow 45° for connection duct system Tee 45° for connection duct system Tee 90° for connection duct system Coupling Duct brackets Vacuum point (surface socket) Wall plate, for vacuum points (building shell) Cover plate, for vacuum points (building protection) Low voltage cable 24 V Mounting material (package) Glue (bottle) Duct, length 1,15 m Installation manual 12318 1 socket 3734 2 socket 3735 3 socket 3736 1 pcs. 2 pcs. 3 pcs. 3 pcs. 7 pcs. 10 pcs. 2 pcs. 4 pcs. 6 pcs. 1 pcs. 1 pcs. 1 pcs. - - 1 pcs. 4 pcs. 3 pcs. 1 pcs. 6 pcs. 5 pcs. 1 pcs. 8 pcs. 6 pcs. 1 pcs. 1 pcs. 2 pcs. 3 pcs. 1 pcs. 2 pcs. 3 pcs. 10 m 1 100 ml 6 pcs. 1 pcs. 17 m 1 100 ml 10 pcs. 1 pcs. 30 m 1 100 ml 14 pcs. 1 pcs. 121 122 | Combi Whole House Unit The energy efficient Building Service Centre Genius - All in one Systemair‘s combi unit „Genius“ efficiently and economically combines the complete building equipment for energy efficient single-family houses. Controlled room ventilation is more and more necessary for houses with modern building standards. New buildings as well as renovated buildings have higher insulation standards with less heating loads. Consequently, conventional heating systems are often over-dimensioned. Systemair‘s combi unit „Genius“ provides the solution - the ventilation system enables heating as well as cooling in an efficient way. This can be achieved by temporarily increasing the volumetric flow in combination with an air-air/air-water-heat pump. The pump also provides higher hot water comfort. Genius optimises HVAC for energy efficient buildings. Therefore, it is possible to conceive self-sufficient and CO2 neutral systems in combination with PV systems. Hot water generation The Genius building services centre is equipped with a 150 litres drinking water reservoir. The service centre ensures hot water comfort because water treatment works during all operating modes. As a consequence, the water is heated to the required temperature parallel to heating or cooling operation. The water reservoir features an electric heating element to guarantee operation at low external temperatures. Control unit The control unit of the building services centre is able to control the complete heating, cooling, hot water system and ventilation. The control unit provides a user level for the owner and a service level for service personnel. The entire control unit can be controlled by an internet application. Controlled room ventilation with heat recovery Controlled room ventilation with integrated heat recovery provides a balanced and agreeable indoor climate. Permanent fresh air supply into living rooms and exhaust of used air guarantee a healthy indoor climate. Heat recovery is provided by a rotating heat exchanger which transfers exhaust air heat to the supply air - the heat remains in the building. Heating and cooling with heat pumps Heating in winter and cooling in summer! This is made possible by a steplessly controlled air-air/air-water-heat pump. The heat pump adjusts its performance according to the requirements for a highly efficient operation. Used air is exhausted from living areas via a separate duct system and led back after treatment (heating or cooling) to living and sleeping areas. This is a pure air heating/cooling system. The exhaust system remains unaffected. Odour or substance transmission from exhausted rooms to supply air is thereby excluded. Genius - Building Services Centre Combi Whole House Unit | All in one The new „Genius“ Systemair Central Building Services Unit for energy efficient residential houses with the functions: • Heating/Cooling/Ventilation • Heat recovery • Hot Water This consists of three modules. The hot water module with stainless steel storage tank, the heat pump module with reversible air to air and air to water heatpump for heating and cooling, the ventilation and energy recovery module with energy saving fans and a rotating heat exchanger with recovery of humidity in winter and dehumidification in summer. Ventilation will be done as usual by two fans. Heating or cooling of the rooms will be provided through the supply or recirculation air ducts. Electrical PTC elements in the supply air elements allow independent control of individual rooms, and if necessary, balance extreme outdoor temperatures. Compared to conventional systems, the Systemair Central Building Services Unit „Genius“ offers additional advantages, all combined in one unit: • Ventilation with heat recovery • Low energy use • No extra radiators required • Intelligent single room control • CO2 and humidity control, optional • Energy saving fans • Hot water production parallel to heating operation • Control system for the the complete building services, designed for efficient comfort operation • Emergency mode for heating and hot water • Legionella function, fast charging hot water • Geothermal heat exchanger, optional • Ventilation unit thermally isolated 123 124 | Combi Whole House Unit Central Building Services Unit „Genius“ in detail ambient air secondary air exhaust air supply air Ventilation module • Rotating heat exchanger with humidity recovery. • Heating and cooling through supply air ducts (recirculation air). Heat pump module exhaust air • Reversible air to air and air to water heat pump for heating, cooling and hot water. • Steplessly controlled compressor to modulate the power exactly to the need of heating and cooling energy. ambient air HP Hot water module • 150 litres stainless steel storage tank for hot water • Hot water production parallel to heating function. • Electric heater with 3 kW power Technical data Genius Heating power kW 5 Cooling power kW 4 Air flow (normal operation) m³/h 250 (100 Pa) Heat recovery bis 88 % Hot water l 150 Electric heater kW 3 Width mm 865 Heigth mm 2070 Depth mm 750 Dimensions Installation and maintenance Easy installation and maintenance due to modular system. HRU Ventilation module HP Heat pump module HW Hot water module Index | 125 Index A AE Air Valves AL Page No IR24-P Self Regulating motorised Air Valves 110 ISO + Various Air Valves 106 K Self Regulating Air Valves B 111 Page No K-EC KVKE-EC Balance - E Balance-E Extract Plastic Air Valve 107 L Balance - S Balance-S Supply Plastic Air Valve 107 LDC Domestic Axial Fan 40 M Humidity & PIR Air Valve 112 MTP 10 BOREA Adjustable Air Valves 109 MVS BRAVO Domestic Centrifugal Fan 170 P BF BHC C CB CBF Page No PK-I-C Electric heater battery 80 R Domestic Centrifugal Fan 42 RDA PIR 24V Insulated Circ Ducting EC Circular Metal Tube Fan EC Compact Acoustic Box Fan Circular Duct Silencer EC Fan Speed Control 0-10V Central Extract Fan Circular Fire Damper 33 Back Draught Shutter RVF Domestic External Wall Fan CF Domestic Centrifugal Fan 42 S CVVX CWK SCD Heat Recovery Wall Grille 104 SPI LPHW Water Heater batteries 80 T D Diffusers DSG Ducting Page No Iris Damper 116 Page No Timer 38 TFSK-EC EC Roof Centrif Fan (Square Base) 28 TFSR-EC EC Roof Centrif Fan (Circ Base) 28 Duckwork & Accessories 91 TFF Circ Diffuser 108 Page No TG EAF LV Domestic Low Voltage Axial Fan 41 TST ECF LV Domestic Low Voltage Centrif Fan 41 Tune-R Motorised VCD 78 V ES 102 39 TSL-1/EC EFS-RCK 31 Silencers 106 35 EFF Silencer, Flexible Pressure Sensor Demand Control System EFD 43 Page No Various Diffusers E EC-Vent T120 117 115 RSK Silencers 44 Constant Air Volume Device 79 39 34 Page No 78 81 102 Page No HRU Control Panel CO2 Sensors 24 Page No HRU Control Panel Cooker hoods 26 Page No CD CO2RT / CO2RT-D 101 Page No CE Cookerhoods 39 Metal Air Valve 106 V20 / V30 5 in 1 Roof Cowl 105 VBC Commercial 6”, 9” & 12” Fans 45 VK F Temperature Sensors 38 Cooker hood 81 Circ Diffuser 108 Single Blade VCD’s 116 Page No Central Vacuum Cleaners 120 LPHW Water Heater Battery Circ 80 Louvre Shutter 32 Page No VR 250 ECH/B Residential Heat Recovery Unit 52 Cooker Hood 81 VR 300 ECV/B Residential Heat Recovery Unit 60 FAV Self Regulating Fresh Air Valves 113 VR 400 DCV/B Residential Heat Recovery Unit 62 FGR Panel Filter Cassette Circ 33 VR 700 DCV Residential Heat Recovery Unit 64 Fast Clamps 30 VSR 300 Residential Heat Recovery Unit 66 Plastic & Metal Flat Ducting 94 VSR 500 Residential Heat Recovery Unit 68 Plastic Duct System 84 VTR 150/K Residential HRU with cookerhood 54 Flexible Ducting Various Flexible Ducting 93 VTR 200/B Residential Heat Recovery Unit 56 FSSSVLF Stainless Steel Air Valve F251 FK Flat Duct Flex + G Genius Geo IGK IF Commercial Heat Recovery Unit 58 Commercial Heat Recovery Unit 74 Commercial Heat Recovery Unit 76 Self-Adjusting Fresh Air Vent 114 Heat Recovery Unit Side Conn 70 Heat Recovery Unit Top Conn 70 122 VTC 700 Geothermal Unit 118 VTK Page No Room Humidiistat I IGC VTC Low E VTC 300 Combi Whole House Unit H HR1 107 Page No 38 Page No Circular Wall Louvre VX 400 E VX 400 EV VX 700 E 31 VX 700 EV Square Wall Terminal 32 W Domestic Shower Axial Fan 40 WBK Heat Recovery Unit Side Conn 70 Heat Recovery Unit Top Conn 70 Page No Mounting Bracket 79 Systemair UK • November 2012 • www.systemair.co.uk www.villavent.co.uk