Category 3 UTP Cable, 25-Pair

Category 3 UTP Cable, 25-Pair
57242-X, 57243-X
Ripcord Under Jacket
Jacket
Conductor
Insulation
Core: 25-Pairs Cabled Together
Pairs: Twisted with Different Lays
Optional Teflon Core Wrap
Nominal Diameter
Description
AMP NETCONNECT Category 3 UTP cables meet or exceed TIA and ISO requirements for Category 3/Class C performance. AMP NETCONNECT
Category 3 cables comply with all of the performance requirements for voice and low speed data up to 10 Mbps 10BASE-T. These cables are
available in plenum and non-plenum, white, gray, blue and yellow, and packaged on wooden reels.
Specification (text in brackets [ ] requires a choice)
Backbone cabling for voice shall be 24 AWG, 25-pair UTP, NEC/NFPA [CMP or CMR] rated and be independently verified for compliance. Cable
jacketing shall be [white, gray, blue or yellow]. [Individual conductors shall be 100% FEP insulated (if plenum)]. Cable shall be independently
verified for performance and exceed all TIA/EIA Category 3 requirements as well as meet the performance requirements listed in the following table:
Performance Characteristics
(meet or exceed TIA/EIA-568-A Category 3)
Insertion Loss
NEXT
Frequency
(dB/100m)
(dB)
MHz
Maximum
Minimum
.772
2.2
43
1
2.5
41
4
5.6
32
8
8.5
27
10
9.7
26
16
13.1
23
20
15.4
22
SRL
(dB)
Minimum
12.0
12.0
12.0
12.0
12.0
9.9
9.0
Cable performance shall be independently verified and characterized to 20MHz. Cable shall be supplied on wooden reels. Cable shall be
independently verified for flammability by UL and listed under file number E138034. Flammability shall comply to NEC article 800 and NFPA 70;
[CMP (NFPA 262, UL 910) or CMR (ANSI/UL 1666, IEC 332-1)]. Backbone voice cable shall be AMP NETCONNECT part number [57242-X or
57243-X].
Part Numbers
Description
NEC/NFPA
Packaging
Rating
CMR
Category 3 UTP Cable, 25-Pair
CMP
Packaging: WR = 1000ft Wooden Reel
WR
WR
White
57242-1
57243-1
Part Numbers
Gray
Blue
57242-5 57242-3
57243-5 57243-3
Yellow
57242-7
57243-7
Category 3 UTP Cable, 25-Pair
57242-X, 57243-X
Technical Details
Mutual Capacitance
Characteristic Impedance
DC Resistance
Conductor DC Resistance
Insulation DC Resistance
CMR
6.6nF/100m nominal
100Ω ±15%, 1 - 20MHZ
9.38Ω /100m maximum
28.6Ω /1000ft maximum
500 MΩ/1000ft maximum
CMP
6.6nF/100m nominal
100Ω ±15%, 1 - 20MHZ
9.38Ω/100m maximum
28.6Ω/1000ft maximum
500 MΩ/1000ft maximum
Propagation Delay
Nominal Velocity of Propagation
Operating Temperature
Storage Temperature
Bend Radius
Packaging
Conductors –
Materials
Insulation –
Jacket –
5.7ns/m maximum @ 10MHz
70%
-20° C – 60° C (-4° F – 140° F)
-20° C – 80° C (-4° F – 176° F)
(4 × cable diameter) ≈ 1”
1000ft (± 2%) Wooden Reel, 97lbs/mft
24 AWG, Solid Copper, (Ø.0201 nominal)
0.0065in (Ø.033 nominal), SR-PVC
0.015in nominal (Ø.325 nominal), FR-PVC
5.7ns/m maximum @ 10MHz
74%
-20° C – 60° C (-4° F – 140° F)
-20° C – 80° C (-4° F – 176° F)
(4 × cable diameter) ≈ 1”
1000ft (± 2%) Wooden Reel, 117lbs/mft
24 AWG, Solid Copper, (Ø.0201 nominal)
0.007in (Ø.034 nominal), SR-PVC
0.014in nominal (Ø.320 nominal), Polymer Alloy
Safety –
Approvals:
Performance
UL LISTED (file number E138034)
for safety to:
CMR – (UL 1666, IEC 332-1)
CMP – (NFPA 262, UL 910)
ETL Verified to:
TIA/EIA-568-A Category 3
Specifications subject to change without notice.
Revised 01/11
http://www.ampnetconnect.com/thailand
©Copyright 2008 by Tyco Electronics Corporation. All Rights Reserved. AMP, AMP NETCONNECT, NETCONNECT, and Tyco are trademarks.