I.c DOO - 004 Sill 0 900 2,100 Bedroom 13 14 15 17 16 18 12 Family Room Manhole 11 Lobby 10 9 8 8 1 7 7 6 5 3 4 1 Ø100 Master Bedroom Master Balcony Master Bedroom Master Balcony DOO - 005 Sill 0 Sill 0 900 2,100 1,500 WD - 002 Ø15 shower Ø15 sink Ø15 w.h.b Ø15 cictern Ø15 shower Ø15 sink Master Bedroom Master Balcony Master Balcony water tank below ground WD - 002 Ø100rain water outlet as fulbora Ø15 cictern drainage Slope DOO - 004 2,100 Ø15 w.h.b Ø50 Master Bath 2,100 Sill 0 Sill 0 Sill 0 900 2,100 DOO - 006 800 DOO - 006 800 2,100 800 2,100 900 Walk in closet 2,100 DOO - 006 Master Bath 800 Sill 0 Ø50 DOO - 004 Sill 1,100 Ø50 Ø50 Ø25 chased in wall Sill 600 1,500 1,500 2,100 Master Bedroom Sill 600 1,000 DOO - 006 WD - 001 Sill 0 Sill 0 Sill 0 900 DOO - 005 800 DOO - 006 800 2,100 800 DOO - 006 Sill 0 2,100 Walk in closet Sill 0 Walk in closet 1,500 900 2,100 Ø100 DOO - 003 2,100 800 Sill 0 DOO - 005 1,000 DOO - 006 900 Sill 1,100 WD - 001 DOO - 003 storm water drainage Ø100 SWVP 2 Ø100 SWVP 2 900 9 7 6 5 4 3 2,100 Sill 0 Lobby 10 3 9 8 2,100 Bedroom Family Room 11 4 10 12 5 11 Family room 2,100 900 1,500 1,200 13 14 15 12 Distribution pipe Ø25 non return valve Bath DOO - 004 17 16 18 DOO - 004 Overflow pipe Ø25 gate valve Ø25 chased in wall going downfloor 2*920L vertical plastic water tank as Kentank CCV46, dimensions:Ø1080*1120 installed on a 200mm plinth and as per manufacturer's instructions 6 2,100 DOO - 005 Sill 0 1,000 600 2,200 Ø50 2,100 800 900 Sill 0 Sill 0 DOO - 002 900 2,100 1 900 Sill 0 Sill 0 2 1 DOO - 004 DOO - 004 Family room Sill 0 2 DOO - 004 Sill 0 900 1,500 1,200 DOO - 002 2,100 800 Sill 0 Sill 0 Sill 0 2,100 Ø25 to bring water from the supply to the tanks. pump 18 2,200 8 3 2,100 Soil waste pipe Ø100 SWVP Ø100 Bedroom 17 9 4 900 Bedroom 16 10 Bedroom DOO - 004 1,400 2,400 Sill 0 Ø50 Bath Ø25 chased in wall going downfloor 15 11 Ø25 to bring water from the supply to the tanks. Ø100 SWVP Ø100 14 900 900 2,100 Sill 0 13 18 17 16 15 14 13 DOO - 004 12 5 Bedroom 2,100 DOO - 004 Sill 0 Sill 0 2,100 Bath Balcony Inspection chamber Gurry Trap DOO - 003 WD - 003 Sill 600 Ø25 chased in wall Balcony DOO - 004 Ø25 chased in wall 2,100 1,500 900 Sill 1,100 Ø25 chased in wall going downfloor Bedroom 1,400 2,400 Ø25 chased in wall to bring water from the supply. Sill 0 Ø25 chased in wall DOO - 004 6 Sill 600 Ø25 chased in wall going downfloor Sill 600 7 1,500 900 1,200 Sill 600 Sill 0 Bedroom Ø25 chased in wall WD - 001 DOO - 003 2,100 600 1,000 Sill 1,100 1,400 2,400 WD - 002 DOO - 004 WD - 003 Ø25 chased in wall going downfloor 2*920L vertical plastic water tank as Kentank CCV46, dimensions:Ø1080*1120 installed on a 200mm plinth and as per manufacturer's instructions Ø25 chased in wall going downfloor Balcony WD - 002 Sill 0 Ø25 chased in wall to bring water from the supply. 1,200 Balcony WD - 001 2,100 1,400 2,400 DOO - 005 Sill 0 gt NOTES Inlet pipe Ø25 KEY Ø100rain water outlet as fulbora pump non return gate valve valve Inlet from NCC gate valve GENERAL: 1. All dimensions to be checked on site before commencement of any work. Usefigured dimensions only. Any discripancies should be reported to the Architect immediately. 2. All dimensions are in milimetres unless otherwise specified . CIVIL WORKS: 1. All soils under slabs and around external fountations to be treated for termite control. 2. All soils on cut emberkments to be stabilised. Slope not to exceed the natural angle of repose. 3. All slabs at ground level to be poured over 1000 gauge polythene sheeting on 50mm stone blinding on hardcore. STRUCTURAL WORKS: 1. All black cotton soils to be removed from all building plinths. All buildings to be clear of black cotton soil to a distance of 3m. 2. All basement columns to be provided with angle iron protection 1500mm high. 3. All paved surfaces to be clear of black cotton soil to a distance of 500mm outside the edge of the surface. 4. Refer to structural Engineers details for all r.c works. 5. Fountation depth to be determined on site to structural Engineer's approval. 6. All walls less than 200mm thick to be reinforced with hoop irons at every alternate course. 7. All adjacent r.c work and masonry walls to be tied with strap irons at every course. MECHANICAL WORKS: 1. All sanitary fittings, doors, windows and lifts to schedules. 2. All plumping and drainage to comply with city council's specifications. 3. All service ducts to be accessible from every floor. 4. SVP denotes soil vent pipe to be provided at the head of drainage. REVISIONS NCC Meter Pump Pump Ø25 chased in wall Ø50 Ø25 chased in wall Laundry Laundry Ø50 Laundry Laundry I.c I.c I.c gt Ø100 Ø100 Ø15 chased in wall Bedroom Ø15 chased in wall Kitchen Ø50 Bedroom Ø100 I.c Ø100 SWVP from above Ø15 chased in wall Kitchen Ø50 gt Ø100 SWVP Ø100 Ø15 chased in wall gt I.c UNDERGROUND WATER TANK Bedroom Ø100 S.V.P Ø50 Kitchen Kitchen Bedroom Ø15 chased in wall 13 14 15 16 17 18 Sill 0 Lounge 2,100 1 2 3 4 5 6 7 1,000 2,100 2,100 1 1,000 2,100 DOO - 003 Ø100 SWVP 7 I.c Book shelf blw Ø40 Bath 9 6 1,600 DOO - 003 W.C Ø100 8 5 2 Dinning 3 3 Dinning 4 4 8 1 5 9 2 6 10 9 Sill 0 Lounge 11 10 7 6 5 3 4 Sill 0 11 8 Book shelf blw PROJECT 4 Bedroomed Massionett. I.c 12 Ø100 SWVP 1 Book shelf blw Ø100 DOO - 003 2 7 DOO - 003 Ø50 12 1,000 13 14 15 16 17 Dinning F 18 8 17 Dinning 9 16 11 10 Ø40 sink Ø100 I.c 12 10 15 Ø25 chased in wall from top floor tank 11 F Ø100 14 12 Ø40 W.H.B 13 18 17 16 15 14 13 Ø25 chased in wall from top floor tank F 18 F Book shelf blw I.c Drawing Title MECHANICAL LAYOUT OF WATER SUPPLY,DRAINAGE AND STORM WATER DRAINAGE. Sill 0 Lounge Lounge Ø40 sink Ø40 W.H.B Client Ø50 Ø100rain water outlet as fulbora Ø100rain water outlet as fulbora Ø100rain water outlet as fulbora W.C Ø100rain water outlet as fulbora Fall 5 degrees Ø100 I.c To main sewer line To main sewer line storm water drainage 5M ROAD storm water drainage Manhole storm water drainage Estate sewege system 5M ROAD Manhole Ø100 Ø100 I.C To main sewer line Ndichu Reuben Waweru Reg-no B76/0480/2009 Allowance below the wall to allow flow of water to the storm water drainage Water from the Mains storm water drainage The University Of Nairobi. Ø40 Bath Ø50 Ø50 Fall 5 degrees water meter Allowance below the wall to allow flow of water to the storm water drainage Sign gt UNDERGROUND WATER TANK 1*920L vertical plastic water tank as Kentank CCV46, dimensions:Ø1080*1120 installed on a 200mm plinth and as per manufacturer's instructions Ø25 chased in wall going down. D.S.Q 1*920L vertical plastic water tank as Kentank CCV46, dimensions:Ø1080*1120 installed on a 200mm plinth and as per manufacturer's instructions Ø25 chased in wall going down. Description D.S.Q Date Site Buru buru Date scale Drawn Checked Drw no Job no March 2012 1:50 NDICHU.R Eng Abungu DRW/BCM/312/2012 JOB/MAY /312/2012