GT Series QuikStart Guide

advertisement
GT SERIES
Multi-Tenant Entry Security
QuikStart Installation Guide
Installation Videos
How-To
Video Link
ATTENTION:
This is an abbreviated Installation Manual, addressing wiring and programming of the GT Series. The
complete GT Series Installation Manual is located on the CD supplied with the GT-BC Bus Control
Unit. Access the PDF file from the CD and print the entire manual if a hard copy is needed. If installing a digital
entry system, the program for loading names and numbers for each tenant is also located on the CD.
SYSTEM WIRING: AUDIO ONLY DIRECT SELECT & DIGITAL DISPLAY ENTRANCE STATIONS
IN
R1 R2
OUT
R1 R2
4-15/16"
IN
R1 R2
OUT
R1 R2
IN
R1 R2
1-1/4" 4-15/16"
OUT
R1 R2
1-1/4" 4-15/16"
GT-1A
IN
R1 R2
OUT
R1 R2
6-7/8"
GT-1A
6-7/8"
6-7/8"
6-7/8"
6-7/8"
GT-1A
6-7/8"
GT-1A
Loop Wiring Method
Max.
of
loop / trunk
GT-1A 25 stations per
GT-1A
IN
R1 R2
1-1/4" 4-15/16"
OUT
R1 R2
1-1/4" 4-15/16"
IN
R1 R2
OUT
R1 R2
1-1/4" 4-15/16"
1-1/4"
Max. wire distance from distribution point to any tenant is 980’.
Max. cumulative wire distance is 8200’.
Refer to page 9 of the GT Series Installation Manual for complete wire distance information.
OUT
R1 R2
4-15/16"
IN
R1 R2
OUT
R1 R2
IN
R1 R2
OUT
R1 R2
1-1/4" 4-15/16" 1P x 21-1/4" 4-15/16"
1P x 2
GT-4Z
R1
R2
Tenant stations shown are
the GT-1A. The GT-1D
tenant stations can also
be used and wire in the
same manner.
2 | GT Series QuikStart Guide
6-7/8"
Trunk Line
No. 3-6
R1
R2
1P x 2
Doorbell
GT-1C
GT-BC
1P x 2
1P x 2
1P x 2
PS24
GT-VBC
GT-BC
R1
+
PS-2420UL
R2
-
PS-2420UL
+
-
PT
GTA-DES
R1 R2
ELM
ELC
ELB
CN2
Entrance Stations (max. 5)
CN1
CN2
CN1
CN2
1P
1P
PS-2420UL
R1 R2
Door
Strike
1-1/4"
1P x 2
1P
1P
*Distribution Point:
NOT provided by
Aiphone. This can be
any device that parallels
or commons the R1 / R2
connection. (Terminal
strip, punch down block,
wire nuts, etc.)
OUT
R1 R2
1P x 2
1P x 2
PT
Power Transformer
(Use proper power
for the Strike or Mag
Lock being used).
IN
R1 R2
1-1/4" 4-15/16"
GT-1C
GT-4Z
1P x 2
*DP
OUT
R1 R2
1-1/4" 4-15/16"
1P x 2
1P
PS24
PS-2420UL
IN
R1 R2
1-1/4" 4-15/16"
GFK-PS
POWER
1P x 2
OUT
1P
x2
R1 R2
IN
R1 R2
Trunk Line No. 2
Loop wiring
(max. 25)
6-7/8"
6-7/8"
6-7/8"
IN
R1 R2
NOTE: Do not mix loop and
homerun wiring methods
on the same trunk.
Trunk Line No. 1
Homerun using
GT-4Z (max. 6)
ELM
GT-MK w/
ELC
GFW-S
ELB
Mag
Lock
GT-MK w/
GFW-S
PT
CN2 (max. 2)
Security Guard /Concierge Stations
PS24
+
-
12-5/8"
871802
18AWG 2 Cond.
Solid Non Shielded
PE Insulated
Homerun
Wiring Method
GT
Standard
GT-1A
GT-1AConfiguration
GT-1A Sample GT-1A
GT-1A
6-7/8"
872002
20AWG 2 Cond.
Solid Non Shielded
PE Insulated
GT-1A
6-7/8"
WIRE TYPE
+
-
CN1
CN3
CN100
CN1
5-5/16"
1/2"
1-3/4"
SYSTEM WIRING: AUDIO / VIDEO ALL-IN-ONE & DIGITAL ENTRANCE STATIONS
GT-1C, GT-1CB, GT-1CS
B1 B2 R1 R2
B1 B27-1/2"
R1 R2
IN
GT-1C, GT-1CB, GT-1CS
A
B1 B27-1/2"
R1 R2
1-3/16"
B1 B2 R1 R2
GT-1C, GT-1CB, GT-1CS
1-3/16"
A
SW1
B
B1 B2 R1 R2
OUT
B1
IN
B27-1/2"
R1 R2
OUT (3)
A
IN
OUT (1)
B
SW1
1-3/16"
B1
B2 R1 R2
LINE OUT
OUT (4)
IN
OUT (2)
B1 B2 R1 R2 B1 B2 R1 R2
GT-4Z
1-3/16"
NOTE: Do not mix loop and
homerun wiring methods
on the same trunk.
1-3/16"
B1 B27-1/2"
R1 R2 IN
B1 B2 R1 R2
5-1/2"
1P x 2
B1 B27-1/2"
R1 R2
IN
B1 B27-1/2"
R1 R2
1-3/16"
B1 B2 R1 R2
OUT (3)
OUT (1)
GT-4Z
1P x 2
B
IN
A
B1 B2 R1 R2 B1 B2 R1 R2
LINE OUT
OUT (4)
OUT (2)
B1 B2 R1 R2 B1 B2 R1 R2
1-3/16"
SW1
B
GT-4Z
B1 B27-1/2"
R1 R2
IN
1-3/16"
1P x 2
Trunk Line
No. 3-6
1P x 2
Doorbell
1P x 2
1P x 2
R1
R2
GT-VBC
R1
R2
GT-BC
+
-
+ 1P
-
GT-BC
1P
R1
R2
PS-2420UL
1P
PS-2420UL
*Distribution Point:
NOT provided by
Aiphone. This can be
any device that parallels
Entrance
Stations
(max. 5)
or commons
the
R1 / R2
connection. (Terminal
strip, punch down block,
wire nuts, etc.)
Tenant stations shown
are the GT-1C. The
GT-2C or GT-1M-L
tenant stations can also
be used and wire in the
same manner.
Note: GT-2C requires
a separate PS-2420UL
power supply.
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
PS24
1P x 2
PS-2420UL
+
- A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
GT-VBC
GTV-DES104
GT-DM
R1 R2 GT-MK
A1 A2w/
GFW-S
GT-MK w/
GFW-S
A1
A2
Security Guard /Concierge Stations (max. 2)
CN3
R1
R2
Door
Strike
PT
ELM
ELC
ELB
CN2
PT
+
5-7/8"
CN1
ELM
ELC
ELB
Mag
Lock
16-1/8"
*DP
A
B
SW1 GT-1C IN
1-3/16"
B1
B2 R1 R2
1P
GT-1C
SW1
GT-1C, GT-1CB, GT-1CS
B1 B27-1/2"
R1 R2
1-3/16"
1P
x2
1-3/16"
1P x 2
1P x 2
IN
1P
IN
A
Trunk Line No. 2
Loop wiring
(max. 25)
B
GFK-PS
B
GT-1C, GT-1CB, GT-1CS
x 2 GT-1CS
GT-1C, 1P
GT-1CB,
SW1
B1 B27-1/2"
R1 R2
16-3/4"
B
GT-4Z
1P x 2A
GT-1C, GT-1CB, GT-1CS OUT
Line No. 1
Homerun using
GT-4Z (max. 6)
IN B1 B27-1/2"
R1 R2
SW1
5-1/2"
1P x 2
SW1
1-3/16"
5-1/2"
OUT
5-1/2"
B
SW1
Trunk
5-1/2"
B1 B2 R1 R2
GT-1C, GT-1CB, GT-1CS
B
5-1/2"
A
A
IN
A
B1 B2 R1 R2 B1 B2 R1 R2
GT-1CB, GT-1CS
GT StandardGT-1C,
Configuration
Sample
SW1
B
GT-1C, GT-1CB, GT-1CS
5-1/2"
B
B1 B27-1/2"
R1 R2
A
SW1
5-1/2"
IN
GT-1C, GT-1CB, GT-1CS
SW1
5-1/2"
OUT
B1 B27-1/2"
R1 R2
A
SW1
B
5-1/2"
SW1
B
GT-1C, GT-1CB, GT-1CS
A
5-1/2"
A
Homerun Wiring Method
Max. of 6 GT-4Zs per loop. SW1 switch must be
set to A on last GT-4Z in the wire loop. Each tenant
station homeruns to a GT-4Z and its SW1 switch
must be set to A.
5-1/2"
Loop Wiring Method
Max. of 25 stations
per loop. SW1 switch
must be set to A on last
monitor in the wire loop.
+
2-11/16"
+
-
CN1
CN3
PS24
CN100
5-5/16"
1/2"
1-3/4"
3
SYSTEM WIRING: EXPANDED SYSTEM
GT-VBX
GT-DA
#2
ON
#3
ON
1 2 3 4
1 2 3 4
#4
#5
ON
ON
1 2 3 4
1 2 3 4
#6
ON
#7
ON
1 2 3 4
#8
1 2 3 4
R1
R2
ON
1 2 3 4
R1
R2
SUB 1B
R1
R2
SUB 2A
R1
R2
R1
R2
R1
R2
R1
R2
~
IN
+
PS24
+
PS24
R1
R2
R1
R2
Audio output to
tenant stations
and / or GT-4Z
units. Max. of
25 tenants per
trunk and 125
total tenants
per GT-BC.
~
R1
R2
*DP
~
R1
R2
GTW-LC
OUT
R1
R2
USB
R1
R2
OUT
~
R1
R2
COMMON 2
GT-MK
IN
R1
R2
R1
R2
R1
R2
R1
R2
R1
R2
PS24
~
COMMON 1
{
Connection
for audio
entrance
modules 9-16
R1
R2
GT-MK
#2
R1
R2
~
R1
R2
+
-
CN1
R1
R2
R1
R2
R1
R2
GT-BC
+
-
+
-
*DP
R1
R2
CN2
GT-BC PS24
ON
1 2 3 4
A1
A2
SUB 2B
1 2 3 4
~
#1
ON
COMMON 2
{
A1
A2
Connection
for video
entrance
modules 9-16
EXP
Video outputs to
tenant stations
and / or GT-4Z
units. Max. of
25 tenants per
trunk and 125
total tenants per
GT-VBC.
+
-
A1
A2
B1
B2
B1
B2
+
-
A1
A2
B1
B2
B1
B2
B1
B2
B1
B2
B1
B2
STD B1
B2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
+
-
A1
A2
SUB 1
A1
A2
B1
B2
B1
B2
SUB 2
A1
A2
GT-VBC
COMMON 1
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
A1
A2
SUB 1A
A1
A2
GT-VA
A1
A2
+
-
R1
R2
GT-BCX
+
-
#1
ON
1 2 3 4
*Distribution Point:
NOT provided by Aiphone.
This can be any device
that parallels or commons
the R1 / R2 connection.
(Terminal strip, punch down
block, wire nuts, etc.)
OPTION CONNECTOR: TENANT STATIONS
6-7/8"
GT-1A
GT-1A
K
KE
RY
RY
SW
SW
S1
S1E
S2
S2E
S3
S3E
(Brown)K
(Red) KE
(Blue) RY
(White) RY
(Gray) SW
SW
(Black) S1
(Orange)S1E
(Black) S2
(Yellow)S2E
(Black) S3
(Purple)S3E
(Black)
option
connector
4-pin4-pin
option
connector
(Brown)
included)
Emergency alarm (not (not
included)
(Red)Emergency alarm
(Blue)
Ext. Signaling (GT-RY)
V+ (Brown)
Ext. Signaling
(GT-RY)
(White)
V+ (Brown)
V - (Red)
(Gray)
Option contact output
V - (Red)
(Black)Option contact output
(Orange)
(Orange)
(Orange)
(Yellow)
Security/Utility
input
1
(Black)Security/Utility input 1
(Yellow)
(Yellow)
Security/Utility input 2
(Black)
Security/Utility input 2
(Purple)
Security/Utility input 3
(Black)
Security/Utility input 3
GT-1C, GT-1CB, GT-1CS
GT-1C
Video out
Video out
5-1/2"
connector
12-pin 12-pin
optionoption
connector
GT-2C
Display transfer
Display transfer
7-1/2"
Option connector
DC
DC
RY
RY
SW
SW
(Yellow)
(Orange)
(Blue)
(White)
(Gray)
(Black)
Doctor call (Automatic entry)
External Signaling (GT-RY)
Option contact output
1-3/16"
Option connector
DC (Yellow)
DC (Orange)
RY (Blue)
RY (White)
SW (Gray)
SW (Black)
4 | GT
Series QuikStart
Guide
4-15/16"
1-1/4"
Doctor call (Automatic entry)
External Signaling (GT-RY)
Option contact output
Only the option connectors for the GT-2C, GT-1C, and GT-1A
are shown here. For information on other tenant station option
connectors and for technical specifications for each connection,
refer to pages 30-31 of the GT Series Installation Manual.
DIP SWITCH SETTINGS: ENTRANCE STATION (REQUIRED)
Entrance ID Setting:
Use SW2 on the GT-DA-L module or SW1 on the GT-DM entrance station to set the ID settings for each entry panel.
Only switches 2, 3, & 4 are used for this setting.
GT-DM
GT-DM
5-7/8"
#1
#2
#3
#4
#5
#6
#7
#8
ON
ON
ON
ON
ON
ON
ON
ON
1 2 3 4
16-1/8"
GT-DA-L
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4
2-11/16"
DIP SWITCH SETTINGS: ENTRANCE STATION (OPTIONAL)
NOTE:
When using the GT-DM, the settings listed below will be done via the keypad / display while in programming mode.
Refer to the GT Series Installation Manual (pages 43 - 49) for set-up instructions.
Guidance Language Setting:
The guidance is set to off (No Guidance) when shipped. Use SW3 on the GT-DA-L module to set the appropriate
language. Only switches 2, 3, & 4 are used for this setting.
GT-DA-L
No Guidance
English
ON
French
ON
1 2 3 4
ON
1 2 3 4
1 2 3 4
Spanish
German
ON
ON
1 2 3 4
Dutch
ON
1 2 3 4
1 2 3 4
Italian
ON
1 2 3 4
(default)
Entrance Monitoring:
Use switch 1 of SW2 on the GT-DA-L module to enable / disable entrance monitoring. Default is “Monitoring not
possible.” Enabling will allow tenants (video tenants only) to ‘call up’ the entrance station and monitor the door area.
GT-DA-L
ON
1 2 3 4
1
Monitoring possible
Monitoring not possible
Room Number Display:
Use switch 2 of SW1 on the GT-NS module to choose between displaying only resident name or displaying resident
name and number. Default is “Display resident name and number.”
GT-NS
ON
1 2 3 4
2
Display only resident name
Display resident name and number
Message Setting:
Use switch 3 of SW1 on the GT-NS module to select between greeting message or operation message on the display.
Default is “Greeting Message.”
GT-NS
ON
1 2 3 4
3
Operation Message
Greeting Message
Camera View:
Use switches 3 & 4 of SW1 on the GT-VA module to set the camera view. The default setting is Zoom.
Zoom 3s>>Wide: Image starts zoomed and after 3 seconds goes wide.
Wide 3s>>Zoom: Image starts wide and after 3 seconds zooms.
GT-VA
ZOOM
ON
1 2 3 4
WIDE
ON
1 2 3 4
ZOOM 3s>>WIDE
ON
1 2 3 4
WIDE 3s>>ZOOM
ON
1 2 3 4
(default)
5
PROGRAMMING: INPUT RESIDENT INFORMATION
NOTE:
The GT digital panel, GT-DM, and GT-MK must be programmed with the resident information before tenant stations can
be addressed. The resident information can be entered using the keypad or by using the software supplied on the CD.
How-To
Entering Resident Info Using Keypad
Step 1:
Step 2:
Step 3:
Step 4:
On the keypad, enter # plus the ID code (*1111). Re-enter ID code.
Video Link
Scroll to RESIDENT INFO. and press Bell button
.
ROOM # will display on the screen. Enter the desired room number (ie: 101, 102, 103, etc.) and press Bell button .
The room number entered will appear on screen along with a space for the Resident Name. Use the
when finished.
Keypad and Arrow buttons to key in the resident name (if desired) and press Bell button
Step 5: Repeat steps 3 & 4 for remaining residents.
Step 6: Press “X” to return to main menu. Scroll to QUIT and press “X” again to exit programming.
Entering Resident Info Using Software
Step 1: Using the CD supplied with the GT-BC, install the GT software and USB cable driver on a PC running
Windows® XP, Windows Vista®, or Windows® 7.
Step 2: Open GT software, click GT System Mode .
Step 3:Select Resident tab.
Step 4: Enter a Room # and Name (if desired) for each resident.
Step 5: Connect the USB cable to the PC and to the GT device being programmed. Ensure that the GT device
being programmed is powered.
Step 6: Refer to the PC’s device manager to determine which COM Port is being used for the cable driver.
COM Port from the menu bar to see the available COM Ports on the PC.
Step 7:Select Connection
Select the COM Port that was verified in Step 6.
Export from the menu bar.
Step 8:Select Connection
(Export sends data to the entrance station. Import pulls data from the entrance station.)
Step 9: A new window will open asking, “Do you want to overwrite the information?” Select Yes .
Step 10: Enter ID code (default is *1111) and click OK .
Data will be transferred.
PROGRAMMING: ADDRESSING TENANTS VIA HAND-SHAKE METHOD
How-To
Direct Select / Push Button Entrance Station Addressing
Step 1:
Step 2:
Step 3:
Step 4:
Remove front cover from entrance station.
To enter programming mode, use a small screwdriver to push and release button under the
rubber cap on front of speaker module (GT-DA-L). The amber LED will begin flashing, then
remain lit. Once lit, the entry panel is in programming mode.
At tenant station, push and release the TALK button or pick up the handset to establish
communication with the entrance station in programming mode.
Push and release the desired Call Button on the entrance station to assign the button to the
tenant station that is active. A blip tone will be heard.
Do not press and hold the Call Button as doing so will clear the memory for this button.
Step 5:
Step 6:
Step 7:
Turn off or hang up tenant station (GT-1A: Push TALK again, GT-1C / GT-2C: Push OFF).
Repeat steps 3-5 for remaining tenant stations.
To exit programming, push the button under the rubber cap on the GT-DA-L module again
and the amber LED will turn off. The system is now ready for use.
6 | GT Series QuikStart Guide
Video Link
PROGRAMMING: ADDRESSING TENANTS VIA HAND-SHAKE METHOD (continued)
GT Digital Display Entrance Station Addressing
Step 3:
Step 4:
Remove front cover from entrance station.
To enter programming, use a small screwdriver to push and release button under the rubber cap
on front of speaker module (GT-DA-L). The amber LED will begin flashing, then remain lit. Once
lit, the entrance station is in programming mode. The LCD will show “CONNECTING” while in
programming mode.
At tenant station, push and release the TALK button or pick up the handset to establish
communication with the entrance station in programming mode.
Scroll to the station number to be programmed or manually dial the number. When the tenant
to assign the address to the
station number is displayed, push and release the Bell button
tenant station that is active. A blip tone will be heard.
16-3/4"
Step 1:
Step 2:
GTV-DES104
Do not press and hold the Bell button as doing so will clear the memory for this address.
Turn off or hang up tenant station (GT-1A: Press TALK again, GT-1C / GT-2C: Press OFF).
Repeat steps 3-5 for remaining tenant stations.
To exit programming, push the button under the rubber cap on the GT-DA-L module again and the
amber LED will turn off. The system is now ready for use.
GT-DM Entrance Station Addressing
Step 1:
Step 2:
Step 3:
Step 4:
5-5/16"
1/2"
GT-DM
While in standby mode, enter # plus ID code (default is *1111). Re-enter ID code.
Use the up / down arrows and scroll to PROGRAMMING . Push the Bell button
to enter
programming mode. The amber LED will begin flashing, then remain lit. Once lit, the entry panel is
in programming mode. The LCD will show “CONNECTING” while in programming mode.
At tenant station, push and release the TALK button or pick up the handset to establish
communication with the entrance station in programming mode.
Scroll to the station number to be programmed or manually dial the number. When the tenant
station number is displayed, push and release the Bell button
to assign the address to the
tenant station that is active. A blip tone will be heard.
16-1/8"
Step 5:
Step 6:
Step 7:
Do not press and hold the Bell button as doing so will clear the memory for this address.
Step 5:
Step 6:
Step 7:
Turn off or hang up tenant station (GT-1A: Press TALK again, GT-1C / GT-2C: Press OFF).
Repeat steps 3-5 for the remaining tenant stations.
To exit programming, press the “X” button on the panel to return to the main menu (the amber LED
will turn off). Scroll to QUIT and press the “X” button again. The system is now ready for use.
5-7/8"
GT-MK Concierge Station Addressing
Step 1:
Step 2:
While in standby mode, enter # plus ID code (default is *1111). Re-enter ID code.
Use the up / down arrows and scroll to PROGRAMMING . Press the Bell button
to enter
programming mode. The LCD will show “CONNECTING” while in programming mode.
Step 3: Pick up the handset on the GT-MK and leave off hook.
Step 4: At tenant station, push and release the TALK button or pick up the handset to establish
communication with the GT-MK in programming mode.
Step 5: Scroll to the station number to be programmed or manually dial the number. When the tenant
station number is displayed, push and release the Bell button
to assign the address to the
tenant station that is active. A blip tone will be heard from the GT-MK handset.
Do not press and hold the Bell button as doing so will clear the memory for this address.
Step 6:
Step 7:
Step 8:
Turn off or hang up tenant station (GT-1A: Press TALK again, GT-1C / GT-2C: Press OFF).
Repeat steps 4-6 for the remaining tenant stations.
To exit programming, press the “X” button on the GT-MK to return to the main menu. Scroll to
QUIT and press the “X” button again. The system is now ready for use.
Transferring Data Between Entrance Stations
The tenant / entrance station hand-shake information can be transferred between entrance stations and / or concierge
stations. The above hand-shake procedure must be done at one entrance station before the transfer can occur.
Refer to page 40 of the GT Series Installation Manual for this procedure.
Never do a transfer from an entrance station or concierge station that has not been addressed with tenant stations.
7
1-3/4"
PROGRAMMING: ADDRESSING TENANTS VIA DIP SWITCH METHOD
Step 1: Set dip switches for all GT-1C and GT-2C stations using the chart
example to the right.
Binary
ID #
(The full GT Dip Switch Setting Worksheet can be found on the CD included with the GT-BC.)
Step 2: Apply power to system.
Step 3: Install the GT software and USB cable driver on a computer running
Windows® XP, Windows Vista®, or Windows® 7.
(Refer to page 6 for COM Port selection steps.)
Step 4:
Step 5:
Step 6:
Step 7:
Open the GT software, select [GT System Mode].
Select the Resident tab.
Enter a Room # and Name for each tenant to be programmed.
Room ID # Setting from the menu bar (see Figure 1).
Select View
Figure 1
Step 8: For each Binary Dip Switch setting made in Step 1, enter the appropriate
ID into the Room ID # Setting field. Ensure that the correct correlation is
kept between tenant name and actual unit (see Figure 2).
Figure 2
Decimal
Dip Switch
Std
Exp
Exp
(Sub 1) (Sub 2)
1
2
3
4
5
6
7
8
S1
A1
B251
1
2
3
4
5
6
7
8
S2
A2
B252
1
2
3
4
5
6
7
8
S3
A3
B253
1
2
3
4
5
6
7
8
S4
A4
B254
1
2
3
4
5
6
7
8
S5
A5
B255
1
2
3
4
5
6
7
8
S6
A6
B256
1
2
3
4
5
6
7
8
S7
A7
B257
1
2
3
4
5
6
7
8
S8
A8
B258
Room ID # Setting:
Use S# for standard
system stations 1-48.
Use A# for expanded
system stations 1-250.
Use B# for expanded
system stations 251-500.
For tenant stations 251-500,
the dip switch assignment is
the same as 1-250.
Tenant stations 1-250 wire
to Sub 1A and Sub 1B of the
GT-BCX while tenants 251-500
wire to Sub 2A and Sub 2B
(see page 4).
Step 9:Select Connection
Export from the menu bar (see Figure 3).
Note: 8 binary digits allows
for 255 unique numbers. Only
numbers 1-250 are used by the
GT system.
(Export sends data to the entrance station. Import pulls data from the entrance station.)
Figure 3
Step 10: Check the LinkData box and select Yes (see Figure 4).
Step 11: Enter ID code (default is *1111) and click OK (see Figure 5).
Data will be transferred.
Figure 4
Figure 5
Visit our website for complete
information and literature on the
GT Series Multi-Tenant Entry
Security System.
www.aiphone.com/home
Aiphone Corporation
1214
8| GT Series QuikStart Guide
1700 130th Ave. NE Bellevue, WA 98005
Ph: (800) 692-0200 Fax: (425) 455-0071
www.aiphone.com tech@aiphone.com
Download