VANESSA WM Wall Mounting Stand-Alone INSTRUCTION SHEET End Feeds - EFR | EFL | EF2 Mounting 1. Install wall brackets (A) as shown using 1/4” bolts (by others) suitable for intended surface. 2. Loosen captive screws (B) and remove endplates (C) from both ends. 3. Remove lens by lifting from end. Use a flat blade screw driver to pry loose. Note: take care not to damage lens or gasket. BRACKET MOUNTING CENTERS NOMINALFIXTURE LENGTH X CL 1.25” 4” 1.5” FIXTURE HEIGHT CL A A NOMINAL FIXTURE LENGTH 16” 3’ 24” 4’ 32” 5. Hang fixture on wall brackets (A) and install supplied screws (D). 6. Connect 1/2” flex conduit to fixture. *Note: for wet locations flex conduit must be liquid tight and pipe thread sealant or teflon tape must be used on threads. X 2’ 4. Remove reflector/liner. D WET LOCATION CONDUIT (BY OTHERS) 1/2” TRADE SIZE WET LOCATION CONNECTOR (BY OTHERS) 7. Make wire connections inside fixture. 8. Reinstall reflector/ liner 9. Reinstall lens. Note: firmly press along entire length of lens to ensure a good seal. B C 10. Reinstall both endplates (C). FEED TYPES EFR - END FEED RIGHT EF2 - ENDS FEED BOTH ENDS EFL - END FEED LEFT Note: To be installed by a qualified electrician per N.E.C. and all local codes. 820-00029 V-1014 Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151 54 VANESSA WM Wall Mounting Stand-Alone INSTRUCTION SHEET Standard Feed - STND Mounting 1. Install wall brackets (A) as shown using 1/4” bolts (by others) suitable for intended surface. 2. Drill hole in wall as shown for flex conduit. Note: size of hole depends on size of conduit connector and must be large enough to allow conduit connector to protrude into wall and allow fixture to tilt as it is hung on wall brackets. BRACKET MOUNTING CENTERS NOMINALFIXTURE LENGTH 3. Loosen captive screws (B) and remove endplates (C) from both ends. X CL 1/2 X 1.25” 4” 1.5” FIXTURE HEIGHT CL DRILL HOLE IN WALL *SEE NOTE (2) A NOMINAL FIXTURE LENGTH A X 2’ 16” 3’ 24” 4’ 32” 4. Remove lens by lifting from end. Use a flat blade screw driver to pry loose. Note: take care not to damage lens or gasket. 5. Remove reflector/liner D 6. Connect 1/2” flex conduit to fixture. Note: for wet locations flex conduit must be liquid tight and pipe thread sealant or teflon tape must be used on threads. 7. Hang fixture on wall brackets (A) and install supplied screws (D). WET LOCATION CONDUIT (BY OTHERS) 8. Make wire connections inside fixture. 1/2” TRADE SIZE WET LOCATION CONNECTOR (BY OTHERS) 9. Reinstall reflector/liner. 10. Reinstall lens. Note: firmly press along entire length of lens to ensure a good seal. 11. Reinstall both endplates (C). B C 12. Seal hole around conduit connector with silicone, caulking or wall patch. Note: To be installed by a qualified electrician per N.E.C. and all local codes. Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 714.550.7118 fax 714.550.7151 55 820-00031 V-1014 Due to a program of continuous improvement instructions are subject to change without notice. © 2014 Birchwood Lighting, Inc. All rights reserved. VANESSA WM Wall Mounting Stand-Alone INSTRUCTION SHEET JBE - J-box Extender Mounting 1. Install a recessed 2” x 4” single gang junction box as shown. 2. Install wall brackets (A) as shown using 1/4” bolts (by others) suitable for intended surface. 3. Loosen captive screws (B) and remove endplates (C) from both ends. BRACKET MOUNTING CENTERS NOMINALFIXTURE LENGTH X CL 1/2 X 1.25” 4” 1.5” FIXTURE HEIGHT CL JUNCTION BOX (PROVIDED BY OTHERS) A NOMINAL FIXTURE LENGTH 5. Remove reflector/liner. A 6. Pierce a small hole in the center of rubber plug (D) using a piece of solid core wire. Push wires from junction box through hole into fixture. X 2’ 16” 3’ 24” 4’ 32” 4. Remove lens by lifting from end. Use a flat blade screw driver to pry loose. Note: take care not to damage lens or gasket. E 7. Hang fixture on wall brackets (A) and install supplied screws (E). 8. Make wire connections inside fixture. B 9. Reinstall reflector/liner. 10. Reinstall lens. Note: firmly press along entire length of lens to ensure a good seal. C 11. Reinstall both endplates (C). D Note: To be installed by a qualified electrician per N.E.C. and all local codes. 820-00033 V-1014 Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151 56 VANESSA CM Ceiling Mounting Stand-Alone INSTRUCTION SHEET STND - Standard Feed Mounting 1. Install ceiling brackets (A) as shown using 1/4” bolts (by others) suitable for intended surface. 2. Drill hole in ceiling as shown for flex conduit. Note: size of hole depends on size of conduit connector and must be large enough to allow conduit connector to protrude into ceiling. BRACKET MOUNTING CENTERS 3. Loosen captive screws (B) and remove endplates (C) from both ends. NOMINALFIXTURE LENGTH X CL 1/2 X 1.25” 4” 1.5” FIXTURE HEIGHT CL DRILL HOLE IN CEILING *SEE NOTE (2) A NOMINAL FIXTURE LENGTH A 5. Remove reflector/liner. X 2’ 16” 3’ 24” 4’ 32” 4. Remove lens by lifting from end. Use a flat blade screw driver to pry loose. Note: take care not to damage lens or gasket. 6. Connect 1/2” flex conduit to fixture. Note: for wet locations flex conduit must be liquid tight and pipe thread sealant or teflon tape must be used on threads. D D WET LOCATION CONDUIT (BY OTHERS) 7. Mount fixture on ceiling brackets (A) and install supplied screws (D). 8. Make wire connections inside fixture. 1/2” TRADE SIZE WET LOCATION CONNECTOR (BY OTHERS) 9. Reinstall reflector/liner 10. Reinstall lens. Note: firmly press along entire length of lens to ensure a good seal. 11. Reinstall both endplates (C). B C Note: To be installed by a qualified electrician per N.E.C. and all local codes. Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 714.550.7118 fax 714.550.7151 57 12. Seal hole around conduit connector with silicone, caulking or wall patch. 820-00032 V-1014 Due to a program of continuous improvement instructions are subject to change without notice. © 2014 Birchwood Lighting, Inc. All rights reserved. VANESSA CM Ceiling Mounting Stand-Alone INSTRUCTION SHEET End Feeds - EFR | EFL | EF2 Mounting 1. Install ceiling brackets (A) as shown using 1/4” bolts (by others) suitable for intended surface. 2. Loosen captive screws (B) and remove endplates (C) from both ends. 3. Remove lens by lifting from end. Use a flat blade screw driver to pry loose. Note: take care not to damage lens or gasket. BRACKET MOUNTING CENTERS NOMINALFIXTURE LENGTH X CL 1.25” 4” 1.5” FIXTURE HEIGHT CL A 5. Mount fixture on ceiling brackets (A) and install supplied screws (D). A NOMINAL FIXTURE LENGTH 6. Connect 1/2” flex conduit to fixture. *Note: for wet locations flex conduit must be liquid tight and pipe thread sealant or teflon tape must be used on threads. X 2’ 16” 3’ 24” 4’ 32” 4. Remove reflector/liner. 7. Make wire connections inside fixture. WET LOCATION CONDUIT (BY OTHERS) 1/2” TRADE SIZE WET LOCATION CONNECTOR (BY OTHERS) 8. Reinstall reflector/ liner B D D 9. Reinstall lens. Note: firmly press along entire length of lens to ensure a good seal. C 10. Reinstall both endplates (C). FEED TYPES EFR - END FEED RIGHT EF2 - END FEED BOTH ENDS EFL - END FEED LEFT Note: To be installed by a qualified electrician per N.E.C. and all local codes. 820-00030 V-1014 Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151 58 VANESSA CM Ceiling Mounting Stand-Alone INSTRUCTION SHEET JBE - J-box Extender Mounting 1.Install a recessed 2” x 4” single gang junction box as shown. 2. Install ceiling brackets (A) as shown using 1/4” bolts (by others) suitable for intended surface. 3. Loosen captive screws (B) and remove endplates (C) from both ends. BRACKET MOUNTING CENTERS NOMINALFIXTURE LENGTH X CL 1/2 X 1.25” 4” 1.5” FIXTURE HEIGHT CL JUNCTION BOX (PROVIDED BY OTHERS) A NOMINAL FIXTURE LENGTH A 5. Remove reflector/liner. 6. Pierce a small hole in the center of rubber plug (D) using a piece of solid core wire. Push wires from junction box through hole into fixture. X 2’ 16” 3’ 24” 4’ 32” 4. Remove lens by lifting from end. Use a flat blade screw driver to pry loose. Note: take care not to damage lens or gasket. B C 7. Mount fixture on ceiling brackets (A) and install supplied screws (E). 8. Make wire connections inside fixture. D 9. Reinstall reflector/liner. E E 10. Reinstall lens. Note: firmly press along entire length of lens to ensure a good seal. 11. Reinstall both endplates (C). Note: To be installed by a qualified electrician per N.E.C. and all local codes. Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 714.550.7118 fax 714.550.7151 59 820-00034 V-1014 Due to a program of continuous improvement instructions are subject to change without notice. © 2014 Birchwood Lighting, Inc. All rights reserved. VANESSA CSS Cable Suspended Stand-Alone INSTRUCTION SHEET CSS - Cable Suspension System Mounting X 1/4”-20 STUD (BY OTHER) A SIDE EXIT GRIPPER D JUNCTION BOX (BY OTHERS) A E SO CORD D B C 4” FIXTURE HEIGHT B C NOMINAL FIXTURE LENGTH 1. Install A Wet Location Surface Mount Junction Box In Desired Location. 2. Install 1/4-20 Studs (By Others) Suitable For Intended Surface As Shown. 3. Attach Side Exit Grippers (A) To 1/4-20 Studs (By Others). 4. Install Studs (B) Into Fixture Endcaps. 5. Insert Cables (D) Into Cable Couplers (C) And Attach To Studs (B). 6. Insert Cables (D) Into Side Exit Grippers (A) And Adjust To Desired Height. 7. Connect SO Cord (E) To Junction Box. Note: Pipe Thread Sealant Or Teflon Tape Must Be Used On Threads. 8. Make Wire Connections Inside Junction Box And Install Cover. Tie Wrap SO Cord (E) To Cable (D). *To service driver/ballast compartment or to install lamps, continue to step 10 10. Loosen captive screws (F) and remove endplates (G) from both ends. 11. Remove lens by lifting from end. Use a flat blade screw driver to pry loose. Note: take care not to damage lens or gasket. 12. Remove reflector/liner. 13. Service as required. 14. Reinstall reflector/liner. 15. Reinstall lens. Note: firmly press along entire length of lens to ensure a good seal. 16. Reinstall both endplates (G). F G NOMINAL FIXTURE LENGTH X 2’ LED 26 3⁄16” 3’ LED 37 13⁄16” 4’ LED 49 7⁄16” 2’ T5 25 5⁄16” 3’ T5 37 1⁄8” 4’ T5 48 15⁄16” 2’ T8 26 7⁄8” 3’ T8 38 7⁄8” 4’ T8 50 7⁄8” Note: To be installed by a qualified electrician per N.E.C. and all local codes. 820-00035 V-1014 Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151 60