instruction sheet vanessa wm

VANESSA WM
Wall Mounting
Stand-Alone
INSTRUCTION SHEET
End Feeds - EFR | EFL | EF2
Mounting
1. Install wall brackets (A) as shown
using 1/4” bolts (by others) suitable
for intended surface.
2. Loosen captive screws (B) and
remove endplates (C) from both
ends.
3. Remove lens by lifting from end.
Use a flat blade screw driver to
pry loose. Note: take care not to
damage lens or gasket.
BRACKET MOUNTING CENTERS
NOMINALFIXTURE LENGTH
X
CL
1.25”
4”
1.5” FIXTURE
HEIGHT
CL
A
A
NOMINAL FIXTURE LENGTH
16”
3’
24”
4’
32”
5. Hang fixture on wall brackets (A)
and install supplied screws (D).
6. Connect 1/2” flex conduit to
fixture. *Note: for wet locations flex
conduit must be liquid tight and
pipe thread sealant or teflon tape
must be used on threads.
X
2’
4. Remove reflector/liner.
D
WET LOCATION CONDUIT (BY OTHERS)
1/2” TRADE SIZE WET LOCATION CONNECTOR
(BY OTHERS)
7. Make wire connections inside
fixture.
8. Reinstall reflector/ liner
9. Reinstall lens. Note: firmly press
along entire length of lens to ensure
a good seal.
B
C
10. Reinstall both endplates (C).
FEED TYPES
EFR - END FEED RIGHT
EF2 - ENDS FEED BOTH ENDS
EFL - END FEED LEFT
Note: To be installed by a qualified electrician per N.E.C. and all local codes.
820-00029
V-1014
Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151
54
VANESSA WM
Wall Mounting
Stand-Alone
INSTRUCTION SHEET
Standard Feed - STND
Mounting
1. Install wall brackets (A) as shown
using 1/4” bolts (by others) suitable
for intended surface.
2. Drill hole in wall as shown for flex
conduit. Note: size of hole depends
on size of conduit connector and must
be large enough to allow conduit
connector to protrude into wall and
allow fixture to tilt as it is hung on wall
brackets.
BRACKET MOUNTING CENTERS
NOMINALFIXTURE LENGTH
3. Loosen captive screws (B) and
remove endplates (C) from both ends.
X
CL
1/2 X
1.25”
4”
1.5” FIXTURE
HEIGHT
CL
DRILL HOLE IN WALL
*SEE NOTE (2)
A
NOMINAL FIXTURE LENGTH
A
X
2’
16”
3’
24”
4’
32”
4. Remove lens by lifting from end.
Use a flat blade screw driver to pry
loose. Note: take care not to damage
lens or gasket.
5. Remove reflector/liner
D
6. Connect 1/2” flex conduit to fixture.
Note: for wet locations flex conduit
must be liquid tight and pipe thread
sealant or teflon tape must be used
on threads.
7. Hang fixture on wall brackets (A)
and install supplied screws (D).
WET LOCATION
CONDUIT (BY OTHERS)
8. Make wire connections inside
fixture.
1/2” TRADE SIZE WET LOCATION
CONNECTOR (BY OTHERS)
9. Reinstall reflector/liner.
10. Reinstall lens. Note: firmly press
along entire length of lens to ensure a
good seal.
11. Reinstall both endplates (C).
B
C
12. Seal hole around conduit
connector with silicone, caulking or
wall patch.
Note: To be installed by a qualified electrician per N.E.C. and all local codes.
Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705
714.550.7118 fax 714.550.7151
55
820-00031
V-1014
Due to a program of continuous improvement instructions
are subject to change without notice.
© 2014 Birchwood Lighting, Inc. All rights reserved.
VANESSA WM
Wall Mounting
Stand-Alone
INSTRUCTION SHEET
JBE - J-box Extender
Mounting
1. Install a recessed 2” x 4” single
gang junction box as shown.
2. Install wall brackets (A) as shown
using 1/4” bolts (by others) suitable
for intended surface.
3. Loosen captive screws (B) and
remove endplates (C) from both
ends.
BRACKET MOUNTING CENTERS
NOMINALFIXTURE LENGTH
X
CL
1/2 X
1.25”
4”
1.5” FIXTURE
HEIGHT
CL
JUNCTION BOX
(PROVIDED BY OTHERS)
A
NOMINAL FIXTURE LENGTH
5. Remove reflector/liner.
A
6. Pierce a small hole in the center
of rubber plug (D) using a piece of
solid core wire. Push wires from
junction box through hole into
fixture.
X
2’
16”
3’
24”
4’
32”
4. Remove lens by lifting from end.
Use a flat blade screw driver to
pry loose. Note: take care not to
damage lens or gasket.
E
7. Hang fixture on wall brackets (A)
and install supplied screws (E).
8. Make wire connections inside
fixture.
B
9. Reinstall reflector/liner.
10. Reinstall lens. Note: firmly
press along entire length of lens to
ensure a good seal.
C
11. Reinstall both endplates (C).
D
Note: To be installed by a qualified electrician per N.E.C. and all local codes.
820-00033
V-1014
Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151
56
VANESSA CM
Ceiling Mounting
Stand-Alone
INSTRUCTION SHEET
STND - Standard Feed
Mounting
1. Install ceiling brackets (A) as
shown using 1/4” bolts (by others)
suitable for intended surface.
2. Drill hole in ceiling as shown
for flex conduit. Note: size of
hole depends on size of conduit
connector and must be large
enough to allow conduit connector
to protrude into ceiling.
BRACKET MOUNTING CENTERS
3. Loosen captive screws (B) and
remove endplates (C) from both
ends.
NOMINALFIXTURE LENGTH
X
CL
1/2 X
1.25”
4”
1.5” FIXTURE
HEIGHT
CL
DRILL HOLE IN CEILING
*SEE NOTE (2)
A
NOMINAL FIXTURE LENGTH
A
5. Remove reflector/liner.
X
2’
16”
3’
24”
4’
32”
4. Remove lens by lifting from end.
Use a flat blade screw driver to
pry loose. Note: take care not to
damage lens or gasket.
6. Connect 1/2” flex conduit to
fixture. Note: for wet locations flex
conduit must be liquid tight and
pipe thread sealant or teflon tape
must be used on threads.
D
D
WET LOCATION CONDUIT
(BY OTHERS)
7. Mount fixture on ceiling brackets
(A) and install supplied screws (D).
8. Make wire connections inside
fixture.
1/2” TRADE SIZE WET
LOCATION CONNECTOR
(BY OTHERS)
9. Reinstall reflector/liner
10. Reinstall lens. Note: firmly press
along entire length of lens to ensure
a good seal.
11. Reinstall both endplates (C).
B
C
Note: To be installed by a qualified electrician per N.E.C. and all local codes.
Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705
714.550.7118 fax 714.550.7151
57
12. Seal hole around conduit
connector with silicone, caulking or
wall patch.
820-00032
V-1014
Due to a program of continuous improvement instructions
are subject to change without notice.
© 2014 Birchwood Lighting, Inc. All rights reserved.
VANESSA CM
Ceiling Mounting
Stand-Alone
INSTRUCTION SHEET
End Feeds - EFR | EFL | EF2
Mounting
1. Install ceiling brackets (A) as
shown using 1/4” bolts (by others)
suitable for intended surface.
2. Loosen captive screws (B) and
remove endplates (C) from both
ends.
3. Remove lens by lifting from end.
Use a flat blade screw driver to
pry loose. Note: take care not to
damage lens or gasket.
BRACKET MOUNTING CENTERS
NOMINALFIXTURE LENGTH
X
CL
1.25”
4”
1.5” FIXTURE
HEIGHT
CL
A
5. Mount fixture on ceiling brackets
(A) and install supplied screws (D).
A
NOMINAL FIXTURE LENGTH
6. Connect 1/2” flex conduit to
fixture. *Note: for wet locations flex
conduit must be liquid tight and
pipe thread sealant or teflon tape
must be used on threads.
X
2’
16”
3’
24”
4’
32”
4. Remove reflector/liner.
7. Make wire connections inside
fixture.
WET LOCATION CONDUIT (BY OTHERS)
1/2” TRADE SIZE WET LOCATION CONNECTOR
(BY OTHERS)
8. Reinstall reflector/ liner
B
D
D
9. Reinstall lens. Note: firmly press
along entire length of lens to ensure
a good seal.
C
10. Reinstall both endplates (C).
FEED TYPES
EFR - END FEED RIGHT
EF2 - END FEED BOTH ENDS
EFL - END FEED LEFT
Note: To be installed by a qualified electrician per N.E.C. and all local codes.
820-00030
V-1014
Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151
58
VANESSA CM
Ceiling Mounting
Stand-Alone
INSTRUCTION SHEET
JBE - J-box Extender
Mounting
1.Install a recessed 2” x 4” single
gang junction box as shown.
2. Install ceiling brackets (A) as
shown using 1/4” bolts (by others)
suitable for intended surface.
3. Loosen captive screws (B) and
remove endplates (C) from both
ends.
BRACKET MOUNTING CENTERS
NOMINALFIXTURE LENGTH
X
CL
1/2 X
1.25”
4”
1.5” FIXTURE
HEIGHT
CL
JUNCTION BOX
(PROVIDED BY OTHERS)
A
NOMINAL FIXTURE LENGTH
A
5. Remove reflector/liner.
6. Pierce a small hole in the center
of rubber plug (D) using a piece of
solid core wire. Push wires from
junction box through hole into
fixture.
X
2’
16”
3’
24”
4’
32”
4. Remove lens by lifting from end.
Use a flat blade screw driver to
pry loose. Note: take care not to
damage lens or gasket.
B
C
7. Mount fixture on ceiling brackets
(A) and install supplied screws (E).
8. Make wire connections inside
fixture.
D
9. Reinstall reflector/liner.
E
E
10. Reinstall lens. Note: firmly press
along entire length of lens to ensure
a good seal.
11. Reinstall both endplates (C).
Note: To be installed by a qualified electrician per N.E.C. and all local codes.
Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705
714.550.7118 fax 714.550.7151
59
820-00034
V-1014
Due to a program of continuous improvement instructions
are subject to change without notice.
© 2014 Birchwood Lighting, Inc. All rights reserved.
VANESSA CSS
Cable Suspended
Stand-Alone
INSTRUCTION SHEET
CSS - Cable Suspension System
Mounting
X
1/4”-20 STUD (BY OTHER)
A SIDE EXIT GRIPPER
D
JUNCTION BOX
(BY OTHERS)
A
E SO CORD
D
B
C
4”
FIXTURE
HEIGHT
B
C
NOMINAL FIXTURE LENGTH
1. Install A Wet Location Surface
Mount Junction Box In Desired
Location.
2. Install 1/4-20 Studs (By Others)
Suitable For Intended Surface As
Shown.
3. Attach Side Exit Grippers (A) To
1/4-20 Studs (By Others).
4. Install Studs (B) Into Fixture
Endcaps.
5. Insert Cables (D) Into Cable
Couplers (C) And Attach To Studs
(B).
6. Insert Cables (D) Into Side Exit
Grippers (A) And Adjust To Desired
Height.
7. Connect SO Cord (E) To Junction
Box. Note: Pipe Thread Sealant
Or Teflon Tape Must Be Used On
Threads.
8. Make Wire Connections Inside
Junction Box And Install Cover.
Tie Wrap SO Cord (E) To Cable (D).
*To service driver/ballast
compartment or to install lamps,
continue to step 10
10. Loosen captive screws (F) and
remove endplates (G) from both
ends.
11. Remove lens by lifting from
end. Use a flat blade screw driver
to pry loose. Note: take care not to
damage lens or gasket.
12. Remove reflector/liner.
13. Service as required.
14. Reinstall reflector/liner.
15. Reinstall lens. Note: firmly
press along entire length of lens to
ensure a good seal.
16. Reinstall both endplates (G).
F
G
NOMINAL FIXTURE LENGTH
X
2’ LED
26 3⁄16”
3’ LED
37 13⁄16”
4’ LED
49 7⁄16”
2’ T5
25 5⁄16”
3’ T5
37 1⁄8”
4’ T5
48 15⁄16”
2’ T8
26 7⁄8”
3’ T8
38 7⁄8”
4’ T8
50 7⁄8”
Note: To be installed by a qualified electrician per N.E.C. and all local codes.
820-00035
V-1014
Birchwood Lighting • 1302 East Hunter Avenue • Santa Ana, CA 92705 • 714.550.7118 fax 714.550.7151
60