Aquaflair Technical Cooling Cooling solutions for industrial, technological and residential systems Range: 6 - 1500 kW Combining cutting-edge technology with energy ef ficiency and environmental protection is what inspired Uniflair to create this product line The experience the company has built up over the years, and its leadership in the sector of precision air-conditioning channelled the technical and functional choices of Uniflair designers, who included technical excellence in the solutions proposed Uniflair policy is one of continuous technological innovation and the Company therefore reserves the right to amend any data herein without prior notice All rights reserved Reproduction in whole or in part is prohibited Contents Air-cooled water chillers and heat pumps with centrifugal fans Air-cooled water chillers and heat pumps with axial fans LRAC/LRAH Air-cooled water chillers and heat pumps with axial fans for outdoor installation Range: 6 ÷ 40 kW page 10 ARAC/ARAH Air-cooled water chillers and heat pumps with axial fans for outdoor installation Range: 40 ÷ 90 kW page 12 ARAC/ARAH Air-cooled water chillers and heat pumps with axial fans for outdoor installation Range: 120 ÷ 260 kW page 14 BRAC Air-cooled water chillers with axial fans for outdoor installation Range: 300 ÷ 750 kW CRCC/CRCH Air-cooled water chillers and heat pumps with centrifugal fans for indoor installations Range: 7 ÷ 35 kW page 32 ARCC/ARCH Air-cooled water chillers and heat pumps with centrifugal fans for indoor installations Range: 40 ÷ 100 kW page 34 Water-cooled water chillers and heat pumps ARWC/ARWH Water-cooled water chillers and heat pumps Range: 50 ÷ 110 kW page 36 page 16 BRWC/BRWH Water-cooled water chillers and heat pumps Range: 300 ÷ 1200 kW page 38 BRAT Air-cooled water chillers with axial fans for outdoor installation - high external temperature version Range: 300 ÷ 750 kW page 18 BCWC Water-cooled water chillers for indoor installation Range: 300 ÷ 1300 kW page 40 BRAH Air to water heat pumps with axial fans for outdoor installation Range: 300 ÷ 700 kW page 20 ARRC Condenserless chiller unit for indoor applications Range: 50 ÷ 100 kW page 42 ²BRAC Air-cooled water chillers with axial fans for outdoor installation Range: 820 ÷ 1490 kW page 22 BRRC Condenserless chiller with remote condenser Range: 300 ÷ 1200 kW page 44 Condenserless units Multi-functional chiller units Air-cooled water chillers in free-cooling version with axial fans ARAF/ARAM Air-cooled water chillers with free-cooling system or ultra low noise free-cooling system ARAF Range: 40 ÷ 70 kW page 24 ARAF Air-cooled water chillers with free-cooling system Range: 120 ÷ 250 kW page 26 BRAF/BRAM Air-cooled water chillers with free-cooling system or ultra low noise free-cooling system Range: 300 ÷ 720 kW page 28 ²BRAF Air-cooled water chillers with free-cooling system Range: 800 ÷ 1350 kW page 30 EPAC/EPAF Multifunctional air-cooled water chiller units with axial fans for outdoor installations Range: 50 ÷ 100 kW page 46 FKCM Fan coil cassette units Range: 2 ÷ 7 kW page 48 UTAT Fan coil cassette units for underfloor istallations Range: 2 kW page 50 Fan coil The product guide contains detailed technical data regarding the units working conditions of each chiller Products Company profile C onstantly growing all over the world I ndustrial A product line designed both for air-conditioning (homes or technological installations) and for industrial cooling processes. With chillers and heat pumps as its main reference points, Uniflair aims to offer its customers a series of complementary products, many of which are highly innovative, combined to produce complete, reliable, energy-efficient systems with the least possible environmental impact. Uniflair was founded at the end of 1988 and quickly managed to conquer an important position among the biggest manufacturers in the world of air conditioning for technological application, as well as chillers and modular access flooring. Initially it only dealt with the national market, however Uniflair’s expansion has now reached Europe and the other continents. It currently has over 60 distributors. The company’s considerable expansion has made it necessary to adapt its working space. Thus, from the first factory measuring 1,200 m², Uniflair has recently moved to a new site which, with a surface area of over 120,000 m², makes use of a production area of 30,000 m², training rooms, conference halls and one of the most innovative research centres in Europe. P recision R ese arch and residential and cooling systems air conditioning units When it comes to air-conditioning rooms and stuctures containing technological equipment, Uniflair is recognized as one of the world’s market leaders for the quality and reliability of its units, as well as for its innovative application solutions. Telephone exchanges, computer centres, laboratories and control rooms require specific products offering top levels of efficiency and great reliability. Wherever optimal functioning of hi-tech processes is a priority, our products assure the right room temperature and humidity conditions by recirculating and filtering the air, cooling, reheating, dehumidifyng and humydifing. All activities are performed under the strict control of microprocessor-based controllers for intelligent management of the system’s operating sequence. and innovation Innovation has always been the mainstay of Uniflair’s development:considerable company resources have been invested in research into new application solutions intended to assure product excellence with an unbeatable level of reliability. The whole production and management system is run based on an ISO 9001 certified quality model. M odul ar access flooring Uniflair has a series of cutting-edge systems capable of producing various kinds of flooring. Some are exclusive, patented solutions, and in total have an annual capacity of around one million mq. All process of the processes are supervised by control systems, which check the manufacturing process every step of the way. Apart from being a functional element essential to the building’s flexibility, Uniflair access floors can also be used to add a high-quality architectural and aesthetic dimension to the interior. Why Uniflair E fficiency - R eliabilit y A coustic I mpact 72 • Indirect free-cooling • Efficiency at partial loads +51% +48% • Choice and optimisation of components +30% - Electronic expansion valve +22% - Scroll compressors +9% - Double screw compressors - High efficiency refrigerants 2 3 4 5 6 1 - “Oil-free” centrifugal compressors with magnetic bearings Step - Flooded evaporators COP percentage increase refers to partial rather than complete loads, 350 kW units equipped with 6 Scroll compressors A dvanced Reduction in sound pollution is one of the most critical factors designers are called on to solve when choosing plant systems. 70 Noise pressure level [dB(A)] Energetic efficiency [%] The issue of energy continues to play an extremely important role regarding operating costs for modern systems. Uniflair’s range of products makes it possible to guarantee maximum service reliability while cutting energy consumption to a minimum: Uniflair chillers offer low-noise solutions with extremely low acoustic impact thanks to: 68 66 • extra-large air side exchangers • specially devised and implemented algorithms which control the rotation speed of the fans • tested, optimised compressor insulation and housing 64 62 60 58 56 Comparison of basic 650 kW unit with equivalent models currently available on the market Tambient: 35°C; Tinlet/outlet water: 7/12°C (data refer to 10 mt, Q=2, coil side) F ree -C ooling controls Text Uniflair produces the software for its units internally. This enables the company to equip each machine with a “tailor made” control which manages all aspects of the unit. Absolute control means: • • • • Precision: the units use advanced algorithms to accurately control the temperature of the chilled water Reliability: each component is continuously monitored to guarantee it is always used within operating limits and will signal any faults before breakdown occurs Local Area Network: Aquaflair chillers can “talk” to each other, resulting in excellent control of multi-unit systems, managing all the cooling resources and units on stand-by (either on a time basis or alarm) Connectivity: Uniflair microprocessor controls can “talk” to the most common supervision systems (Building Management Systems) including: Modbus, Bacnet, LonWorks, Trend, Metasys, TCP/IP and SNMP Fig. A Mechanical cooling operation 15° C This operating principle uses external air to remove the heat from the liquid to be cooled, providing the system requirements at no cost. Therefore, the lower the ambient temperature during operating hours is, the greater the energy savings are. The sophisticated microprocessor control automatically manages operation in three different situations. During summer, the unit acts like a traditional air-cooled chiller (Fig. A). As the outside temperature drops, the air can be used directly to pre-cool the water, thus lowering the number of hours the compressor is in operation (Fig. B). Should the ambient temperature be such that it is possible to supply all the cooling capacity the system requires, the compressors will be excluded and the water chilled using external air only (Fig. C). This technology makes it possible to drastically reduce energy consumption, cut compressor operating hours and increase reliability. Cooling capacity [kW] 120 190 560 External temperature trend Fig. B Mixed cooling operation [°C] 5° C 30000 25000 20000 15000 10000 5000 0 Constant state of the chilled water temperature compared to considerable differences in outdoor temperatures 23.00 00.00 01.00 02.00 03.00 04.00 Time [hh:mm] - 8 -1 / 20 Fig. C Free-cooling operation Energy savings [kWh] 42700 - 21% 92000 - 28% 244000 - 17% 35000 Energy Absobed - [kWh] Chilled water temperature trend Area Northern Italy Central Europe Spain 4 -1 6/ -1 0 -1 2/ -1 /-6 -8 /-2 -4 free-cooling series 2 0/ 6 4/ 10 8/ 4 /1 12 8 /1 16 2 /2 20 6 /2 24 cooling only series 0 /3 28 4 /3 32 8 /3 36 Text [°C] Annual energy consumption of a 200 kW cooling group - climatic profile of Milan, annual energy savings 78000kWh (-25%) Free-cooling Intelligent Free-cooling By combining free-cooling and Redundancy logic (n+1 / n+n), it is possible to also exploit the air/water exchangers of the unit(s) in stand-by. By connecting all of the air/water exchangers, it is possible to make the water which is to be cooled flow all of the available exchangers, therefore increasing the Free-cooling capacity. Free-cooling coil Additional annual energy saving • Compared to traditional Free-cooling: up to 7% depending on the climate • Compared to a traditional system: up to 50% pump Free-cooling pump pump evaporator Tr aditional F ree -C ooling U nit U nifl air F ree -C ooling A A F E U nit without onboard pumps B B F A E F E A A B F with onboard pumps D B D E B E A Free-cooling coil B Free-cooling pump C Evaporator D Main pump (onboard the unit) E Non return valve F Motorized valve Typical IT Installation - London 24 hours, 7 days per week operation 7°C/12°C chilled water Payback period 0.7 years Standard chiller 1425 0 € 0 Traditional Free-cooling 1194 19% - € 25406 Uniflair Free-cooling 1160 23% - € 29092 1600 1400 1200 Standard chillers 90 Frankfurt Rome 80 70 Intelligent Free-cooling chillers [%] 36 % 18 % Milan 357 31 % 50 Manchester 373 33 % 40 Paris 304 26 % 30 Amsterdam 452 43 % 20 0 -12/-10 -10/-8 -8/-6 Uniflair Free-cooling [MWh] 394 220 Vs 60 800 Traditional Free-cooling Not supplied by Uniflair Annual energy saving 100 10 Standard Chiller E 110 1000 600 B D Supplied by Uniflair 120 Annual absorbed energy - [MWh] Energy absorbed (yearly) MWh Energy saving (yearly) % Annual saving € Benefits • Main Pumps sized only to overcome resistance of standard evaporator • Extremely reliable free-cooling pump • No 3-way valve • Capacity with in-built free-cooling up to 1450 kW Annual absorbed energy - [MWh] Problems • Pumps sized 24/7 to overcome resistance of Free-cooling coil and the 3-way valve •3-way valve low reliability A single unit -6/-4 -4/-2 -2/0 connected units 0/2 2/4 * London 4/6 6/8 8/10 10/12 12/14 External Temperature [°C] Stockholm 487 49 % Madrid 301 25 % Berlin 411 38 % London 394 36 % Copenhagen 462 44 % LRAC-LRAH Technical D ata Air-cooled water chillers and heat pumps with axial fans designed for outdoor installation Range: Cooling capacity: 6 ÷ 40 kW Heating capacity: 7 ÷ 43 kW Available versions - low noise - Top Operating Performance Refrigerant R410A Scroll Compressor/s Total O per ating P erformance • Designed with a minimal footprint • Self-supporting frame in galvanised steel (colour RAL7037) with panels varnished with epoxy powders in compliance with the ASTM B117 norm • One hermetic Scroll compressor (023B - 090A models) with internal thermal protection and anti-vibration feet • Two hermetic Scroll compressors (120A - 180A models) with internal thermal protection and anti-vibration feet • Crankcase heaters (*) • Ecological refrigerant: R410A • Refrigerant circuit in compliance with EC norms (PED 97/23/EC directive) in copper tubes mainly including a filter dryer, water flow switch, thermostatic valve with external equalisation (stainless steel made) and high and low pressure switches • Cycle inversion on the refrigerant side with 4-way reversing valve (*) • Stainless steel, brazed plate heat exchanger insulated with closed-cell, expanded polyurethane • Anti-freeze heater on evaporator (*) • Air side heat exchanger with aluminium fins and mechanicallyexpanded copper tubes • Metal grille panel to protect the air side heat exchanger • Axial fans, statically and dynamically balanced, with sickle-blades and with safety protection grilles • Sound-proofing polymeric impeller for each fan • Condensation control including continuous regulation of fan speed • Electric panel conforming to EC Directive 73/23/EC and Directive EMC 89/336/EC with auxiliary 12V circuit, general cut-off switch, magneto-thermal protection cut-off switches • UECH microprocessor control system with local user control and monitoring terminal with LCD display and LED signals for all working parameters: chilled/hot (*) water temperature regulation, anti-freeze protection, compressor timing and protection, fan speed regulation, alarm code signalling, centralization for general alarm control and remote ON-OFF switch • Water flow differential pressure switch • Predisposition for cooling / heating systems with heating panels • Rubber anti-vibration feet • Electronic Expansion Valve • Hot gas by-pass disposal for a constant outlet water temperature (optional; only LRAC) • Advanced UPCOxs microprocessor control system with specific algorithm to: - outlet water temperature regulation for a high level of precision even without the water tank - advanced management of compressors run through automatic set-point sensitivity regulation - advanced management of the de-frosting function to minimise cycle inversions (*) - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers (up to 10 units, with 1 or 2 stand-by units) • Moreover, the microprocessor control system enables: - remote cycle inversion (*) - the set point adjustment by an 0-10V external signal - the management and selection of double set-point - free contact for general alarm and 2 addressable alarm - remote ON-OFF control - the ability to interface with main external communications protocols: Modbus, Bacnet, Lonworks, Metasys, TCP/IP and SNMP 023B V/ph/Hz Power supply kW Cooling capacity (1) kW Absorbed power (1) COP (1) kW Heating capacity (2) kW Absorbed power (2) dB(A) Noise pressure level (3) Nr. of fans / Nr. of poles Nr. circuits / Nr. of compressors Compressor type Evaporator l Water tank Dimensions and weight mm Height mm Depth mm Width kg Weight (without hydronic kit) kg Weight (version with pump) Weight (version with water tank and pump) (4) kg 230 / 1 / 50 400 / 3 + N / 50 6 8 10 14 17 19 27 1.5 2.2 2.9 4.4 4.9 6.0 8.7 4.0 3.6 3.5 3.2 3.5 3.3 3.1 6.7 9.0 10.9 15.5 18.9 22.1 30.2 1.7 2.3 2.8 3.9 4.7 5.5 8.5 34 34 34 35 37 38 38 1 / 6 1 / 6 1 / 6 1 / 6 2 / 6 2 / 6 2 / 6 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 1 1 / 2 Scroll Plate 25 25 25 50 50 50 100 650 458 1274 100 104 116 032B 041B 650 458 1274 101 105 117 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; R410a refrigerant (2) Data refer to nominal conditions: water temperature 40/45°C; ambient temperature 7°C d.b. 6°C w.b.; R410A refrigerant 650 458 1274 103 107 119 054A 1271 458 1273 152 159 179 067A 090A 1271 458 1273 160 167 187 1271 458 1273 162 169 189 120A 1271 615 2054 262 273 300 137A 180A 33 10.0 3.2 36.7 10.0 40 3 / 6 1 / 2 39 12.0 3.2 43.5 11.9 41 4/6 1/2 100 100 1271 615 2054 272 281 308 1271 615 2054 282 291 318 (3) Measured in free field at 10 mt. (Q=2, front) from the unit running in nominal conditions (4) Data refer to empty unit C onstruc tion O p tions O p tions • On-board water tank and pump • High head pressure pump (*) • Condensing Unit (*) • Low external temperature option: unit works down to - 20°C • Production of glycol water mixture at low temperatures option (down to - 10 °C) • Anti-freeze protection on evaporator, water tank and pump • RS485 serial adaptor used to communicate with Uniflair supervisory system or to interface with external BMS • LON FTT10 serial adaptor used to communicate with external BMS managed with LON protocol • TCP/IP serial adaptor used to interface with external BMS • Condensing coils equipped with safety grilles and filter • Remote user terminal for: - display / entering of commands - display unit status and alarms • Chilled / hot water piping filter (*) on request 05REF661X1A - v 1.0 S tandard F e atures LRAC/LRAH MODELS (*) Standard only for LRAH 10 11 ARAC - ARAH Technical D ata 0182A ARAC/ARAH MODELS Power supply Cooling only (ARAC) Cooling capacity (1) Absorbed power (1) Heat pump (ARAH) Heating capacity (2) Absorbed power (2) Nr. of circuits / Nr. of compressors Nr. of fans / Nr. of poles Airflow Water flow Pressure drop Available head pressure (3) Pump absorbed power Noise pressure level (4) Ultra low noise version Noise pressure level (4) Partial heat recovery (option) Thermal heat recovery (5) Water flow Dimensions and weight Height Depth Width Weight (without hydronic kit) (6) Air-cooled water chillers and heat pumps with axial fans for outdoor installations Range: Cooling capacity: 40 ÷ 90 kW Heating capacity: 50 ÷ 106 kW Available versions: - basic - ultra low noise Refrigerant R407C Scroll Compressors 12 O p tions • Self-supporting frame in galvanised steel (colour RAL9001) with panels varnished with epoxy powders in compliance with ASTM B117 • Protection grade IP44 • Hermetic scroll compressors with internal thermal protection and anti-vibration supports • Crankcase heaters (AR AH) with modulating condensation control option • Stainless steel brazed plate heat exchangers insulated with closed-cell expanded polyurethane • Heat exchangers with aluminium fins and mechanically-expanded copper tubes • Cycle inverter with 4-way reversing valve (ARAH) • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles: protection grade IP44 • Two independent refrigerant circuits conforming to EC Directives (PED 97/23/EC directive) including: filter dryer, flow indicator, thermostatic valves with external equalisation and high & low pressure switches • Low-noise version: due to the particular dimensions of the aeraulic circuit and low-speed fans • Electric panel conforming to EC Directive 73/23/EC and Directive EMC 89 / 336 / EC with auxiliary 24 V circuit, general cut-off switch, magneto-thermal protection cut-off switches • Sequence phase control • Water flow differential pressure switch • Microprocessor control system including: local user control and monitoring terminal with LCD display and LED signals for all working parameters: - chilled water temperature regulation and hot water temperature for ARAH - anti-freeze protection - compressor timing and protection - compressor function display - alarm code signalling and centralisation for general alarm control transmission - remote ON-OFF switch Units can be supplied with the following construction options: • Remote user terminal (up to 150 meters) for: - direct display/entering of commands - display unit status and alarms • Remote user terminal mP20 II (up to 200 meters) for: - display / entering of commands - display unit status and alarms • Rubber anti-vibration kit kW kW kW kW m³/h l/h kPa kPa kW dB(A) dB(A) 0202A 0232A 0302A 0403A 0504A 74.7 26.48 84.7 30.36 95.0 35.29 65.9 74.0 81.4 17.93 19.87 23.13 2/2 6/6 6/6 6/6 21000 21000 21000 9790 11480 12820 25 30 29 158 155 150 1.50 1.50 1.50 45.0 45.0 45.0 95.4 28.9 2/3 8/6 28000 14580 32 179 2.35 46.0 105.6 34.87 2/4 8/6 28000 16340 36 165 2.35 46.0 42.1 14.66 49.4 17.30 50.1 56.8 13.09 14.91 4/6 4/6 14000 14000 7240 8500 20 22 211 186 1.34 1.34 43.0 43.0 56.9 19.86 0252A 400 / 3 + N / 50 66.7 22.06 41.0 41.0 43.0 43.0 43.0 44.0 44.0 kW l/h 13.2 2280 15.9 2750 16.9 2920 19.7 3390 24.5 4210 27.5 4740 32.8 5650 mm mm mm kg 1542 1950 1191 530 1542 1950 1191 550 1542 2300 1191 620 1542 2300 1191 635 1542 2300 1191 655 1542 3200 1191 800 1542 3200 1191 850 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature (4) Measured in free field conditions, coil side, direction factor Q=2, at 10 mt. from the 35°C; refrigerant R407C unit (at nominal conditions) (2) Data refer to nominal conditions: water temperature 40/45°C, ambient temperature (5) Data refer to nominal conditions: recovery water temperature 40/45°C; chilled water 7°C dry bulb, 6°C wet bulb; refrigerant R407C temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (3) With re-circulating pump (6) Data refer to empty unit Available water tanks Available pump group ARAC / ARAH A (1.34 kW) B (1.50 kW) C (2.36 kW) 0182A / 0202A opz. opz. opz. 0232A / 0252A / 0302A n.d. opz. opz. 0403A / 0504A n.d. n.d. opz. opz.= option; n.a.= not available ARAC / ARAH A (210 l) B (300 l) C (500 l) 0182A / 0202A opz. n.d. n.d. 0232A / 0252A / 0302A opz. opz. n.d. 0403A / 0504A opz. opz. opz. opz.= option; n.a.= not available C onstruc tion O p tions 05REF531A1A - v 1.1 S tandard F e atures V/ph/Hz • Modulating condensation control through automatic fan speed regulation • Ultra low-noise version and modulating control of condensation pressure • Integrated hydronic system with 1 or 2 pumps (1 + 1 standby), with safety valve and reservoir tank • Partial condensation heat recovery and modulating control of condensation pressure (ARAC only) • Microprocessor control system mP20 II with the management of capacity steps (ARAC only) • Electronic expansion valve (*) • Outlet water temperature control (*) • RS4 85 serial adaptor used to communicate with Uniflair supervision system or to interface with external BMS • RS485 Serial adaptor for mP20 II control: - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication proto- cols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP • LAN card for local network connection mP20 II (ARAC only) • Cascade management ready for 2, 3 or 4 units installed on a parallel hydraulic circuit connection (only for standard control) • High and low refrigerant pressure gauges • Version for the production of glycol water at low temperatures (down to - 8 °C) ARAC only (*) • Compressor power phase correction capacitors • Anti-freeze protection on evaporator, reservoir tank and pump group • Condensing coils equipped with safety grilles • R22 refrigerant (available option on request according to UE 2037/2000 standards) • Condensing version (*) • R134a Refrigerant (*) (*) on request 13 ARAC - ARAH Technical D ata ARAC/ARAH MODELS 0574A 0644A V/ph/Hz Cooling only (ARAC) Cooling capacity (1) kW 118 135 Absorbed power (1) kW 42 49 Heat pump (ARAH) Heating capacity (4) kW 129 141 Absorbed power (4) kW 38 41 Noise pressure level min/max (3) dB(A) 50 / 57 50 / 57 Condenser air flow (1) m³/h 44000 44000 Low noise version Cooling capacity (1) kW 112 128 Absorbed power (1) kW 35 52 Noise pressure level (3) dB(A) 47 47 Condenser air flow (1) m³/h 35000 35000 Nr. circuits / Nr. of compressors 2 / 4 2 / 4 Nr. of fans / Nr. of poles 2 / 6 2 / 6 Nr. condensing coil Evaporator type/ Nr. External hydraulic connections (1) l/h 20300 23200 Pressure drop evaporator kPa 40 45 Pressure drop evaporator with pump group kPa 80 95 Pump group (option) Available head pressure (2) (std pump group) kPa 190 230 Available head pressure (2) (H.P. pump group) kPa 260 310 Water tank (option) Water tank capacity l 500 500 Partial heat recovery (option) Exchanger type / Nr. Thermal heat recovery (5) kW 46 48 Water flow l/h 7912 8256 Total heat recovery (option) Exchanger type / Nr. Thermal heat recovery (5) kW 166 178 Water flow l/h 28550 30616 Power supply Air-cooled water chillers and heat pumps with axial fans for outdoor installations Range: Cooling capacity: 120 ÷ 260 kW Heating capacity: 129 ÷ 285 kW­ Available versions: - standard - modulating condensation control - low-noise Refrigerant R407C Scroll Compressors S tandard F e atures 14 - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced anti-freeze protection on evaporator (*) - advanced defrost function (only for ARAH) - integrated LAN card for local network connection of a group of chillers (up to 10 units with 1or 2 units in stand-by) • Moreover microprocessor control system permit: - an overlapped management of units as a single chiller (up to 10) - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm management - remote ON-OFF switch - abilit y to inter face with Modbus protocol directly on RS4 85 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP 1084A 1204A 165 54 190 73 230 84 260 95 179 64 51 / 58 68120 220 79 51 / 58 66000 255 84 52 / 59 89000 285 85 52 / 59 89000 158 180 56 78 48 48 52000 53350 2 / 4 2 / 4 3 / 6 3 / 6 1+1 Shell & Tube / 1 28400 32700 44 39 97 78 219 88 50 69240 2 / 4 4 / 6 245 102 50 69240 2/4 4/6 39600 48 103 44800 35 105 200 290 140 310 140 300 130 300 500 500 650 650 Plate / 2 53 75 9116 12900 76 13072 86 14792 Shell & Tube / 2 207 278 35600 47816 318 54696 350 60200 2140 4542 1344 1754 2058 2140 5242 1344 2182 2537 2140 5242 1344 2290 2648 Dimensions and weight Height Depth Width Weight (without hydronic kit) (6) Weight (with water tank and 2 pumps) (6) mm mm mm kg kg 1618 3807 1193 1237 1519 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (2) With pump group (3) Measured in free field conditions, coil side, direction factor Q=2, at 10 mt. from the unit (at nominal conditions) (*) Standard only for ARAH O p tions 1618 3807 1193 1271 1554 2140 4542 1344 2001 2321 (4) Data refer to nominal conditions: water temperature 40/45°C, ambient temperature 7°C dry bulb, 6°C wet bulb; refrigerant R407C (5) Data refer to nominal conditions: recovery water temperature 40/45°C; chilled water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (6) Data refer to empty unit C onstruc tion O p tions Units can be supplied with the following construction options: • Remote user terminal mP20 II (up to 200 metres) for: - entering of commands - display unit status and alarms • Spring anti-vibration kit • Rubber anti-vibration kit 05REF626A1A - v 1.2 • Self-supporting frame in galvanised steel (colour RAL7037) with panels finished in epoxy powders • Four hermetic Scroll compressors with internal thermal protection and anti-vibration supports • Two refrigerant circuits conforming to EC norms (PED 97/23/CE) in copper tubes mainly including : filter dryer, flow indicator, thermostatic valves with external equalisation, high and low pressure switches and high and low pressure transducer • Compressor crankcase heaters (*) • Exchange of the cycle on the refrigerant side with 4-way reversing valve (only for ARAH) • Shell & tube water/refrigerant heat exchanger with two independent cooling side circuits and one hydraulic circuit: the heat exchanger is insulated with closed-cell expanded neoprene • Heat exchanger coil with aluminium fins and mechanically-expanded copper tubes • Water flow pressure switch • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles (internal and external) protection grade IP54 • Condensation pressure control switch ON-OFF • Electric panel conforming to EC (Directive 73/23/EC and Directive EMC 89/336/EC) with anti-condensation heater (*), auxiliary circuit, general cut-off switch, magneto-thermal protection cut-off switches • Sequence phase control • Microprocessor control system UPC1m including: - local user terminal mP20 II visible on unit with panel - outlet chilled water temperature regulation - advanced management of compressors run throught automati set-point sensitivity regulation - compressor rotation with FIFO system (run time, protection and function) 0744A 0964A 400 / 3 / 50 • Standard version with modulating condensation control • Low noise version with modulating condensation control through special algorithm and sound-proofing of compressor housing • Version for production of glycol water mix ture at low temperatures down to - 10 °C (ARAC) • Partial / total condensation heat recovery • Set-point adjustment from external signal 0-10V • Integrated hydronic system with 1 or 2 pumps (1 + 1 standby), reservoir tank, safety valves, expansion tank ( each pump is equipped with a non-return valve and interceptive valve) • Reser voir tank equipped with pump for primar y circuit management • High and low pressure gauges • Power phase correction capacitors (compressors + fans + pumpgroup) • Anti-freeze protection on evaporator, reservoir tank and pump group • Condensing coils equipped with safety grilles and filter • Discharge interception valves on compressor • Sound-proofing of compressor housing • Clock card • RS4 85 serial adapter used to communicate with Uniflair supervision system or to interface with external BMS • Condensing coil cataphoresis treatment • R134a Refrigerant (*) • Condensing version (*) (*) on request 15 BRAC Technical D ata BRAC MODEL Air-cooled water chillers with axial fans for outdoor installation Range: Cooling capacity: 300 ÷ 750 kW Available versions: - basic - low noise Refrigerant R407C/R134a* Scroll and double Screw Compressors S tandard F e atures 16 1306A 1506A 1802A 2002A 2202A 2502A - monitoring of refrigerant charge (with E.E.V.) - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers - Integrated clock card • Microprocessor control system with: - set-point adjustment from external signal 0-10V - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm management - remote ON-OFF switch - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP (1) Data refer to nominal conditions: water temperature 12/7°C; external temperature 35°C; refrigerant R407C (2) Unit equipped with compressors with economiser, data refer to nominal conditions: water temperature 12/7°C; external temperature 35°C; refrigerant R407C 2802A 3002A 627 668 250.4 255.3 67.0 3.3 3.2 8 / 6 697 746 247.1 251.9 67.5 3.8 3.8 10 / 6 566 600 294.9 303.3 57.0 3.2 3.1 8 / 6 633 674 272.9 279.5 57.5 3.5 3.4 10 / 6 2525 6360 2200 2525 7785 2200 (3) Measured in free field conditions, coil side, direction factor Q=2, at 10 mt. from the unit (at nominal conditions) (4) European Seasonal Energy Efficiency Ratio (*) For units with economiser max ambient temperature decreases of 2°C C onstruc tion O p tions • Economiser option: available only for models equipped with screw compressors increases cooling capacity and COP • Low external temperature option: unit works down to - 20°C • Low noise version: with sound-proofing of Scroll compressors or sound-proofed casing and low fan speed • Production of glycol water mixture at low temperatures option (down to - 10 °C) • Electronic expansion valve (E.E.V.) • Partial / total condensation heat recovery • Integrated hydronic system with 1 or 2 pumps • High and low pressure gauges O p tions Units can be supplied with the following construction options: • Remote user terminal mP20 II (up to 200 metres) for: - entering of commands - display unit status and alarms • Spring anti-vibration kit • Anti-freeze protection on evaporator, and pump group • Evaporator / pumps protection grilles • Condensing coils equipped with safety grilles and filter • Suction shut-off valves on compressor • RS485 serial adaptor used to communicate with Uniflair supervisory system or to interface with external BMS • LON FTT10 serial adaptor used to communicate with external BMS managed with LON protocol • Condensing coil cataphoresis treatment (*) (*) on request 05REF647X1A - v 1.0 • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL7037) • Six hermetic Scroll compressors with internal thermal protection and anti-vibration supports (1206A ÷ 1506A models) • Two semi-hermetic Screw compressors with internal thermal protection, oil heters and anti-vibration supports (1802A ÷ 3002A models) • Two refrigerant circuits conforming to EC norms (PED 97/23/CE) in copper tubes mainly including: filter dryer, flow indicator, thermostatic valves with external equalisation (E.E.V. optional), discharge shut-off valve, high and low pressure switches and high and low pressure transducer • Shell & tube evaporator with two independent cooling side circuits and one hydraulic circuit: the heat exchanger is insulated with closed-cell expanded neoprene • Condensing coil with aluminium fins and internally grooved copper tubes • Water flow pressure switch • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles, protection grade IP54 • Modulating condensation control by fan speed regulation of one line • Electric panel conforming to EC (Directive 73/23/EC and Directive EMC 89/336/EC, protection grade IP54) with anti-condensation heater (with low external temperature option), maximum internal temperature control, general cut-off switch, magneto-thermal protection for fans and auxiliaries, magneto-thermal protection for Scroll compressors and fuses for screw compressors, cut-off switches • Sequence phase monitor • Microprocessor control system UPC1m including: - local user terminal mP20 II visible on unit with panel - outlet chilled water temperature regulation - advanced management of compressors (units equipped with Scroll compressors) or of 8 steps (units equipped with screw compressors) throught automatic set-point sensitivity regulation; compressor rotation with FIFO system (run time, protection and function) 1206A 400 / 3 / 50 400 / 3 / 50 Power supply V/ph/Hz 6 x Scroll / 2 2 x Screw / 2 Compressors / circuits nr. x mod 1 x Shell & Tube 1 x Shell & Tube Evaporator nr. x mod Cooling only - basic version (ambient temperature max 45°C*) 298 338 371 410 455 511 557 Cooling capacity (1) kW -- -- -- 438 490 545 593 Cooling capacity ECO (2) kW 118.7 122.5 138.3 157.6 149.4 182.1 219.5 Absorbed power (1) kW -- -- -- 160.5 151.6 184.9 223.1 Absorbed power ECO (2) kW 61.5 62.5 62.5 63.0 64.0 64.5 64.5 Noise pressure level (3) dB(A) 4.2 4.1 4.2 3.6 3.9 3.3 3.1 ESEER (4) -- -- -- 3.6 3.8 3.2 3.0 ESEER / ECO (4) 4 / 6 6 / 6 6 / 6 6 / 6 8 / 6 8 / 6 8 / 6 Nr. of fans / Nr. of poles Cooling only - Low noise version (ambient temperature max 43°C*) 274 315 350 382 424 470 512 Cooling capacity (1) kW -- -- -- 406 455 499 542 Cooling capacity ECO (2) kW 132.3 135.7 151.1 174.8 160.4 198.2 239.0 Absorbed power (1) kW -- -- -- 179.0 163.5 202.2 243.3 Absorbed power ECO (2) kW 55.0 56.0 56.0 56.0 56.5 57.0 57.0 Noise pressure level (3) 4.2 4.0 4.1 3.3 3.6 3.2 3.0 ESEER (4) -- -- -- 3.3 3.5 3.1 3.0 ESEER / ECO (4) 4 / 6 6 / 6 6 / 6 6 / 6 8 / 6 8 / 6 8 / 6 Nr. of fans / Nr. of poles Dimensions 2525 2525 2525 2525 2525 2525 2525 Height mm 3500 4930 4930 4930 6360 6360 6360 Length mm 2200 2200 2200 2200 2200 2200 2200 Width mm 17 BRAT Technical D ata BRAT MODEL Air-cooled water chillers with axial fans for outdoor installation - High external temperature version Range: Cooling capacity: 300 ÷ 750 kW Available versions: - basic - low noise - ultra-low noise Refrigerant R407C/R134a* Scroll and double Screw Compressors S tandard F e atures 18 - monitoring of refrigerant charge (with E.E.V.) - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers - Integrated clock card • Microprocessor control system with: - set-point adjustment from external signal 0-10V - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm management - remote ON-OFF switch - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP 1306A (1) Data refer to nominal conditions: water temperature 12/7°C; external temperature 35°C; refrigerant R407C (2) Unit equipped with compressors with economiser, data refer to nominal conditions: water temperature 12/7°C; external temperature 35°C; refrigerant R407C O p tions 1506A 1802A 2002A 2202A 2502A 2802A 3002A 638 679 240.3 244.1 67.5 3.2 3.2 10 / 6 696 746 241.9 246.4 67.5 3.6 3.8 10 / 6 584 619 268.7 274.5 57.5 3.1 3.0 10 / 6 644 687 268.6 275.1 57.5 3.5 3.4 10 / 6 552 584 285.1 291.7 53.5 3.0 3.0 10 / 6 601 638 290.1 297.9 53.5 3.5 3.4 10 / 6 2525 7785 2200 2525 7785 2200 (3) Measured in free field conditions, coil side, direction factor Q=2, at 10 mt. from the unit (at nominal conditions) (4) European Seasonal Energy Efficiency Ratio (*) For units with economiser max ambient temperature decreases of 2°C O pzioni C ostrut tive Units can be supplied with the following construction options: • Remote user terminal mP20 II (up to 200 metres) for: - entering of commands - display unit status and alarms • Spring anti-vibration kit 05REF648X1A - v 1.0 • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL7037) • Six hermetic Scroll compressors with internal thermal protection and anti-vibration supports (1206A ÷ 1506A models) • Two semi-hermetic Screw compressors with internal thermal protection, oil heters and anti-vibration supports (1802A ÷ 3002A models) • Two refrigerant circuits conforming to EC norms (PED 97/23/CE) in copper tubes mainly including: filter dryer, flow indicator, thermostatic valves with external equalisation (E.E.V. optional), discharge shut-off valve, high and low pressure switches and high and low pressure transducer • Shell & tube evaporator with two independent cooling side circuits and one hydraulic circuit: the heat exchanger is insulated with closed-cell expanded neoprene • Condensing coil with aluminium fins and internally grooved copper tubes • Water flow pressure switch • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles, protection grade IP54 • Modulating condensation control by fan speed regulation of one line • Electric panel conforming to EC (Directive 73/23/EC and Directive EMC 89/336/EC, protection grade IP54) with anti-condensation heater (with low external temperature option), maximum internal temperature control, general cut-off switch, magneto-thermal protection for fans and auxiliaries, magneto-thermal protection for Scroll compressors and fuses for screw compressors, cut-off switches • Sequence phase monitor • Microprocessor control system UPC1m including: - local user terminal mP20 II visible on unit with panel - outlet chilled water temperature regulation - advanced management of compressors (units equipped with Scroll compressors) or of 8 steps (units equipped with screw compressors) throught automatic set-point sensitivity regulation; compressor rotation with FIFO system (run time, protection and function) 1206A 400 / 3 / 50 400 / 3 / 50 Power supply V/ph/Hz 6 x Scroll / 2 2 x Screw / 2 Compressors / circuits nr. x mod 1 x Shell & Tube 1 x Shell & Tube Evaporator nr. x mod Cooling only for high temperature Basic version (ambient temperature max 50°C*) 317 351 378 415 455 511 577 Cooling capacity (1) kW -- -- -- 445 489 545 614 Cooling capacity ECO (2) kW 108.3 123.1 136.5 146.5 147.7 182.5 205.9 Absorbed power (1) kW -- -- -- 148.3 149.8 185.4 208.2 Absorbed power ECO (2) kW 62.5 62.5 62.5 64.0 64.0 64.5 66.5 Noise pressure level (3) dB(A) 4.2 4.2 3.7 3.5 3.9 3.3 3.1 ESEER (4) -- -- -- 3.5 3.8 3.2 3.1 ESEER / ECO (4) 6 / 6 6 / 6 6 / 6 8 / 6 8 / 6 8 / 6 10 / 6 Nr. of fans / Nr. of poles Cooling only for high temperature Low noise version (ambient temperature max 46°C*) 298 328 353 389 434 480 539 Cooling capacity (1) kW -- -- -- 415 465 509 572 Cooling capacity ECO (2) kW 116.1 133.0 151.7 156.5 160.0 201.7 223.4 Absorbed power (1) kW -- -- -- 159.1 162.9 205.8 226.8 Absorbed power ECO (2) kW 56.0 56.0 56.0 56.5 56.5 57.0 57.5 Noise pressure level (3) dB(A) 4.2 4.2 3.3 3.2 3.7 3.4 3.1 ESEER (4) -- -- -- 3.1 3.6 3.3 3.0 ESEER / ECO (4) 6 / 6 6 / 6 6 / 6 8 / 6 8 / 6 8 / 6 10 / 6 Nr. of fans / Nr. of poles Cooling only for high temperature Ultra low noise version (ambient temperature max 43°C*) 284 313 339 371 403 457 504 Cooling capacity (1) kW -- -- -- 395 431 484 534 Cooling capacity ECO (2) kW 123.1 142.0 160.3 166.1 169.6 209.1 234.5 Absorbed power (1) kW -- -- -- 169.3 173.4 213.6 238.4 Absorbed power ECO (2) kW 52.0 52.0 52.0 52.5 52.5 52.5 53.5 Noise pressure level (3) dB(A) 4.1 4.2 3.0 3.1 3.7 3.2 2.9 ESEER (4) -- -- -- 3.1 3.6 3.1 2.8 ESEER / ECO (4) 6 / 6 6 / 6 6 / 6 8 / 6 8 / 6 8 / 6 10 / 6 Nr. of fans / Nr. of poles Dimensions 2525 2525 2525 2525 2525 2525 2525 Height mm 4930 4930 4930 6360 6360 6360 7785 Length mm 2200 2200 2200 2200 2200 2200 2200 Width mm • Economiser option: available only for models equipped with screw compressors increases cooling capacity and COP • Low external temperature option: unit works down to - 20°C • Low noise version: with sound-proofing of Scroll compressors or sound-proofed casing and low fan speed • Ultra-low noise version: with sound-proofing of Scroll compressors or sound-proofed casing and vibration absorbers for screw compressors and ultra-low fan speed (control on each row) • Production of glycol water mixture at low temperatures option (down to - 10 °C) • Electronic expansion valve (E.E.V.) • Partial / total condensation heat recovery • Integrated hydronic system with 1 or 2 pumps • High and low pressure gauges • Anti-freeze protection on evaporator, and pump group • Evaporator / pumps protection grilles • Condensing coils equipped with safety grilles and filter • Suction shut-off valves on compressor • RS485 serial adaptor used to communicate with Uniflair supervisory system or to interface with external BMS • LON FTT10 serial adaptor used to communicate with external BMS managed with LON protocol • Condensing coil cataphoresis treatment (*) (*) on request 19 BRAH Technical D ata 1206A BRAH MODEL Air to water heat pumps with axial fans for outdoor installations Power supply Compressors / circuits Evaporator Nr. of fans / Nr. of poles Basic version Cooling capacity (1) Cooling capacity ECO (2) Absorbed power (1) Absorbed power ECO (2) Heating capacity (3) Absorbed power (3) Noise pressure level (4) Ultra low noise version Cooling capacity (1) Cooling capacity ECO (2) Absorbed power (1) Absorbed power ECO (2) Heating capacity (3) Absorbed power (3) Noise pressure level (4) Dimensions Height Length Width Range: Cooling capacity: 300 ÷ 700 kW Heating capacity: 340 ÷ 750 kW Available versions: - basic - ultra-low noise Refrigerant R407C Scroll and double Screw Compressors S tandard F e atures • Sequence phase monitor • Microprocessor control system UPC1m including: - local user terminal mP20 II visible on unit with panel - outlet chilled / heat water temperature regulation - advanced management of compressors (units equipped with Scroll compressors) or of 8 steps (units equipped with screw compressors) through automatic set-point sensitivity regulation - compressor rotation with FIFO system (run time, protection and function) - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced defrost function to minimise cycle inversions - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers (up to 10 units) - integrated clock card • Moreover microprocessor control system permits: - set-point adjustment from external signal 0-10V - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm - management - remote ON-OFF switch - abilit y to interface with Modbus protocol directly on RS4 85 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP 1506A 1802A 2002A 2202A 2502A 2802A 3002A 8 / 6 10 / 6 V/ph/Hz 400 / 3 / 50 nr. x mod 6 x Scroll / 2 nr. x mod 1 x Shell & Tube 4 / 6 6 / 6 6 / 6 6 / 6 400 / 3 / 50 2 x Screw / 2 1 x Shell & Tube 8 / 6 8 / 6 8 / 6 kW kW kW kW kW kW dB(A) 298 - 118 - 340 116 61.5 338 - 122 - 405 133 61.5 371 - 138 - 439 143 63.0 410 438 157 160.5 462 153 63.0 455 490 149 151.6 492 156 64.0 511 545 182 184.9 567 177 65.0 557 593 219 223.1 632 205 66.0 627 668 250 225.3 710 234 67.0 697 746 247 251.9 750 237 67.0 kW kW kW kW kW kW dB(A) 274 - 132 - 317 117 55.0 315 - 136 - 380 131 55.0 350 - 151 - 411 141 56.0 382 406 175 179.0 430 150 57.0 424 455 160 163.5 462 154 57.0 470 499 198 202.2 526 174 57.0 512 542 239 243.3 584 201 57.0 566 600 295 303.3 656 230 57.0 633 674 273 279.5 697 233 57.5 mm 2527 mm 3500 mm 2200 2527 4930 2200 2527 4930 2200 2527 4930 2200 2527 6360 2200 2527 6360 2200 2527 6360 2200 2527 6360 2200 2527 7785 2200 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (2) Unit equipped with compressors with economiser, data refer to nominal conditions: water temperature 12/7°C; external temperature 35°C; refrigerant R407C (3) Data refer to nominal conditions: water temperature 40/45°C; ambient temperature 7° C d.b. 6°C w.b.; refrigerant R407C (4) Measured in free field at 10 mt. (Q=2, coil side) from the unit running in nominal conditions C onstruc tion O p tions O p tions • Ultra-low noise version: with sound-proofing of Scroll compressors or sound-proofed casing and low fan speed • Partial heat recovery • Integrated hydronic system with 1 or 2 pumps (1 + 1) • Anti-freeze protection on evaporator, and pump group • Evaporator / pumps protection grilles • Heat exchange coils equipped with safety grilles and filter • Suction shut-off valves on compressors • RS485 serial adaptor used to communicate with Uniflair supervisory system or to interface with external BMS • LON FTT10 serial adaptor used to communicate with external BMS managed with LON protocol • Air-side heat exchangers cataphoresis treatment (*) Units can be supplied with the following construction options: • Remote user terminal mP20II (up to 200 metres) for: - entering of commands - display unit status and alarms. • Spring anti-vibration kit (*) on request 05REF666X1A - v 1.1 • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL7037) • Six hermetic Scroll compressors with internal thermal protection, oil heaters and anti-vibration supports (1206A ÷ 1506A models) • Two semi-hermetic double Screw compressors with internal thermal protection, oil heaters and anti-vibration supports (1802A ÷ 3002A models) • Two refrigerant circuits conforming to EC norms (PED 97/23/CE) in copper tubes mainly including: filter dryer, flow indicator, thermostatic valves with external equalisation, discharge shut-off valve, high and low pressure switches, pressure transducers and pressure gauges • Exchange of the cycle on the refrigerant side with 4-way reversing valve • Shell & tube evaporator with two independent cooling side circuits and one hydraulic circuit: the heat exchanger is insulated with closed-cell expanded neoprene • Heat exchanger coils with aluminium fins and internally grooved copper tubes • Water flow pressure switch • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles, protection grade IP54 • Modulating condensation control by fan speed regulation • Electric panel conforming to EC (Directive 73/23/EC and Directive EMC 89/336/EC, protection grade IP54) with anti-condensation heater, maximum internal temperature control, general cut-off switch, magneto-thermal protection for fans and auxiliaries, magneto-thermal protection for Scroll compressors and fuses for screw compressors, cut-off switches 1306A 20 21 ²BRAC Technical D ata 3604A ²BRAC MODEL Air-cooled water chillers with axial fans for outdoor installation Power supply Compressors / circuits Evaporator Nr. of fans / Nr. of poles Basic version Cooling capacity (1) Cooling capacity ECO (2) Absorbed power (1) Absorbed power ECO (2) Noise pressure level (3) ESEER (4) ESEER / ECO (4) Low noise version Cooling capacity (1) Cooling capacity ECO (2) Absorbed power (1) Absorbed power ECO (2) Noise pressure level (3) ESEER (4) ESEER / ECO (4) Dimensions Height Length Width Range: Cooling capacity: 820 ÷ 1490 kW Available versions: - basic - low noise Refrigerant R407C/R134a* Double Screw Compressors S tandard F e atures 22 - monitoring of refrigerant charge (only with E.E.V.) - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers (up to 5 units) - Integrated clock card • Moreover microprocessor control system permits: - set-point adjustment from external signal 0-10V - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm - management - remote ON-OFF switch - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP 4404A 5004A 5604A 6004A 12 / 6 16 / 6 820 910 876 980 315 299 321 303 66.0 67.0 3.6 3.9 3.6 3.8 400 / 3 / 50 4 x Screw / 4 2 x Shell & Tube 16 / 6 16 / 6 16 / 6 20 / 6 1022 1090 364 370 67.5 3.3 3.2 1114 1186 439 446 67.5 3.1 3.0 1254 1336 501 511 70.0 3.3 3.2 1394 1492 494 504 70.5 3.8 3.8 kW kW kW kW dB(A) 764 812 350 358 59.0 3.3 3.3 848 910 321 327 59.5 3.6 3.5 940 998 396 404 60.0 3.2 3.1 1024 1084 478 487 60.0 3.0 3.0 1132 1200 590 607 60.0 3.2 3.1 1266 1348 546 559 60.5 3.5 3.4 mm mm mm 25 25 9960 2200 2525 12820 2200 2525 12820 2200 2525 12820 2200 2525 12820 2200 2525 15670 2200 V/ph/Hz nr. x mod nr. x mod kW kW kW kW dB(A) (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (2) Unit equipped with economiser, data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (3) Measured in free field at 10 mt. (Q=2, coil side) from the unit running in nominal conditions (4) European Seasonal Energy Efficiency Ratio C onstruc tion O p tions O p tions • Low-noise version: with sound-proofed casing and low fan speed • Electronic expansion valve (E.E.V.) • Economiser option: available only for models equipped with screw compressors increases cooling capacity and COP • Partial heat recovery • Production of glycol water mixture at low temperatures (down to - 10°C) • High and low pressure gauges • Integrated hydronic system with 1 or 2 pumps (1 + 1) • Anti-freeze protection on evaporator, and pump group • Evaporator / pumps protection grilles • Condensing coils equipped with safety grilles and filter • Suction shut-off valves on compressors • RS485 serial adaptor used to communicate with Uniflair supervisory system or to interface with external BMS • LON FTT10 serial adaptor used to communicate with external BMS managed with LON protocol • Condensing coil cataphoresis treatment (*) Units can be supplied with the following construction options: • Remote user terminal mP20 II (up to 200 meters) for: - entering of commands - display unit status and alarms • Spring anti-vibration kit (*) on request 05REF671X1A - v 1.2 • Self-supporting frame in galvanized steel with panels finished in epoxy powders (colour RAL7037) • Four semi-hermetic double Screw compressors with internal thermal protection, oil heaters and anti-vibration supports; moreover the compressors can be equipped with the Economiser (optional) • Four refrigerant circuits conforming to EC norms (PED 97/23/CE) in copper tubes mainly including: filter dryer, flow indicator, thermostatic valves with external equalisation (E.E.V. optional), discharge shut-off valve, high and low pressure switches and high and low pressure transducers • Two shell & tube evaporator with two independent cooling side circuits and one hydraulic circuit: the heat exchanger is insulated with closed-cell expanded neoprene • Condensing coil with aluminium fins and internally grooved copper tubes • Water flow pressure switch • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles, protection grade IP54 • Modulating condensation control by fan speed regulation • Double electric panel conforming to EC (Directive 73 /23 / EC and Directive EMC 8 9 / 33 6 / EC, protection grade IP 5 4 ) wi th anti-condensation heater (with low external temperature option), maximum internal temperature control, general cut-off switch, magneto-thermal protection for fans and auxiliaries, fuses for compressors and cut-off switches • Sequence phase monitor • Microprocessor control system UPC1m including: - local user terminal mP20 II visible on unit with panel - outlet chilled water temperature regulation - advanced 16 steps of the compressors management through automatic set-point sensitivity regulation; - compressor rotation with FIFO system (run time, protection and function) 4004A 23 ARAF - ARAM Technical D ata Air-cooled water chillers with free-cooling system and ultra-low noise free-cooling system Range: ARAF: Cooling capacity: 40 ÷ 70 kW ARAM: Cooling capacity: 36 ÷ 76 kW Available versions: - free-cooling - ultra low noise free-cooling Refrigerant R407C Scroll Compressors S tandard F e atures 24 - anti-freeze protection - compressor timing and protection - compressor function display - alarm code signalling and free-contact for general alarm control transmission - refrigerant high and low pressure sensor - remote ON-OFF switch O p tions 0152A 0252A 0302A Units can be supplied with the following construction options: • Remote user terminal mP20 II (up to 200 meters) for: - display / entering of commands - display unit status and alarms • Rubber anti-vibration kit 56.9 35.2 20.3 66.7 36.7 22.5 74.6 37.7 26.9 4 / 4 16000 8680 182 51 6 / 4 21000 9790 167 52 6 / 4 21000 11480 155 52 6/4 21000 12820 150 52 1542 1950 1191 620 1542 1950 1191 640 1542 2300 1191 730 1542 2300 1191 745 1542 2300 1191 765 36.1 43.3 23.6 30.6 12.2 14.1 4 / 6 6 / 6 13000 18400 7240 7450 206 206 41 43 51.1 32.1 16.5 56.0 32.9 20.4 65.5 34.2 22.8 76.6 43.3 25.4 6 / 6 18400 8780 179 43 6 / 6 18400 9630 169 43 6 / 6 18400 11270 157 43 8/6 23800 13180 146 44 1542 2300 1191 730 1542 2300 1191 745 1542 2300 1191 760 1542 3200 1191 920 - - - - 1542 1950 1191 610 A (1.34 kW) B (1.50 kW) C (2.36 kW) ARAM A (1.34 kW) B (1.50 kW) C (2.36 kW ) 0182A / 0202A opz. opz. opz. 0152A / 0182A / 0202A opz. opz. opz. 0202A 0232A 400 / 3 + N/ 50 50.3 28.4 17.0 2/2 2/2 1542 2300 1191 715 (4) Data refer to nominal conditions: inlet water temperature 15°C; ambient temperature 5°C; glycol 20% (5) Data refer to empty unit Available water tanks Available pump group ARAF 0182A - 42.7 - 27.3 - 14.5 - 4 / 4 - 16000 - 7360 - 209 - 51 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C; glycol 20% (2) With re-circulating pump (3) Measured in free field conditions, coil side, direction factor Q=2, at 10 mt. from the unit (at nominal conditions) 0232A / 0252A / 0302A ARAF n.d. opz. opz. A (210 l) B (300 l) C (500 l) 0232A/ 0252A / 0302A ARAM n.d. opz. opz. A (210 l) B (300 l) C (500 l) opz.= option; n.a.= not available 0182A / 0202A 0232A / 0252A / 0302A opz. n.d. n.d. 0152A / 0182A/ 0202A opz. opz. n.d. 0232A / 0252A / 0302A opz. opz. ( n.d. for 0152A) n.d. opz. opz. n.d. (opz. only 0302A) opz.= option; n.a.= not available C onstruc tion O p tions 05REF536A1A - v 1.1 • Exclusive free-cooling system completely managed by micro processor control mP20 II • Ultra-low noise free-cooling version (ARAM) • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL9001) in compliance with ASTM B117: protection grade IP44 • Hermetic scroll compressors with internal thermal protection and anti-vibration supports • Compressor crankcase heater • Stainless steel brazed plate heat exchangers insulated with closed-cell expanded polyurethane • Heat exchanger coil (free-cooling) with aluminium fins and mechanically-expanded copper tubes • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles: protection grade IP44 • Modulating condensation control through automatic fan speed regulation • Two independent refrigerant circuits conforming to EC Directives (PED 97/23/EC directive) including: filter dryer, flow indicator, thermostatic valves with external equalisation and high & low pressure switches • Electric panel conforming to EC Directive 73/23/EC and Directive EMC 89 /336/EC with auxiliary circuit, general cut-off switch, magneto-thermal protection cut-off switches • Sequence phase control • mP20 II microprocessor control system including: - local user control and monitoring terminal with large LCD display and LED signals for unit status display - chilled water temperature regulation - integrated LAN card for connection to the local network of more than one chiller (up to 10 units) ARAF/ARAM MODELS Power supply V/ph/Hz Free-cooling (ARAF) Cooling capacity (1) kW Cooling capacity free-cooling (4) kW Absorbed power (1) kW Nr. of circuits / Nr. of compressors Nr. of fans / Nr. of poles Airflow m³/h Water flow l/h Available head pressure (2) kPa Noise pressure level (3) dB(A) Dimensions and weight Height mm Depth mm Width mm Weight (only with free-cooling pump) (5) Kg Free-cooling ultra low noise (ARAM) kW Cooling capacity (1) kW Cooling capacity free-cooling (4) kW Absorbed power (1) Nr. of circuits / Nr. of compressors Nr. of fans / Nr. of poles Airflow m³/h Water flow l/h Available head pressure (2) kPa Noise pressure level (3) dB(A) Dimensions and weight Height mm Depth mm Width mm Weight (only with free-cooling pump) (5) Kg • Integrated hydronic system with 1 or 2 pumps (1 + 1 standby), with safety valve and reservoir tank • Partial condensation heat recovery • Discharge water temperature control • RS485 Serial adaptor for mP20 II control: - abilit y to inter face with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP • High and low refrigerant pressure gauges • Compressor power phase correction capacitors • Anti-freeze protection on evaporator • Free-cooling coils protection filters • R22 Refrigerant (available on request according to UE 2037/2000 standards) • R134a Refrigerant (*) (*) on request 25 ARAf Technical D ata Air-cooled water chillers with axial fans and free-cooling system Range: Cooling capacity: 120 ÷ 250 kW Available versions: - standard with modulating condensation control - low noise Refrigerant R407C Scroll Compressors S tandard F e atures 26 - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers (up to 10 units with 1or 2 units in stand-by) • Moreover microprocessor control system permit: - an overlapped management of units as a single chiller (up to 10) - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm management - remote ON-OFF switch - abilit y to interface with Modbus protocol directly on RS4 85 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP 0574A Power supply V/ph/Hz Basic version Cooling capacity (1) kW Absorbed power (1) kW Cooling capacity free-cooling (4) kW Absorbed power free-cooling (4) kW Condenser air flow (4) m³/h Noise pressure level (3) dB(A) Low noise version Cooling capacity (1) kW Absorbed power (1) kW Cooling capacity free-cooling (4) kW Absorbed power free-cooling (4) kW Condenser air flow (1) m³/h Noise pressure level (3) dB(A) Nr. circuits / Nr. of compressors Nr. of fans / Nr. of poles Nr. condensing coil / Nr. free-cooling coil Evaporator type / Nr. Water flow with std. pump (1) l/h Pressure drop evaporator (1) kPa Pump group (option) Available head pressure (2) (std pump group)kPa Available head pressure (2) (H.P pump group)kPa Water tank (option) Water tank capacity l Partial heat recovery (option) Exchanger type / Nr. Thermal heat recovery (5) kW Water flow l/h Dimensions and weight Height mm Depth mm Width mm Weight (only with free-cooling pump) (6) Kg Weight (water tank, 2 + f.c. pump) (6) Kg 115 131 43 50 82 85 5.7 6.3 39500 39500 57 57 161 56 146 8.4 61600 58 108 122 43 55 68 70 4.3 5.1 29800 29800 48 48 2 / 4 2 / 4 2 / 6 2 / 6 21700 24700 52 58 O p tions Units can be supplied with the following construction options: • Remote user terminal mP20 II (up to 200 metres) for: - entering of commands - display unit status and alarms • Spring anti-vibration kit • Rubber anti-vibration kit 0644A 0744A 0964A 1084A 1204A 185 75 152 7.9 61600 58 224 86 196 9.9 79300 59 253 99 202 10.0 79300 59 152 172 59 82 123 127 6.5 6.0 46900 46900 49 49 2 / 4 2 / 4 3 / 6 3 / 6 1+1/ 1+1 Shell & Tube / 1 30400 35000 57 50 210 93 163 7.4 54500 50 2 / 4 4 / 6 233 109 166 7.6 54500 50 2/4 4/6 42300 62 47700 47 400 / 3 / 50 190 260 230 310 200 290 140 310 140 300 130 300 500 500 500 500 650 650 46 48 7912 8256 Plate / 2 53 75 9116 12900 76 13072 86 14792 2140 4542 1344 2164 2468 2140 5242 1344 2682 3037 2140 5242 1344 2790 3148 1618 3807 1193 1417 1699 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; glycol 20%; refrigerant R407C (2) With pump group (3) Measured in free field conditions, coil side, direction factor Q=2, at 10 mt. from the unit (at nominal conditions) 1618 3807 1193 1451 1734 2140 4542 1344 2411 2731 (4) Data refer to nominal conditions: inlet water temperature 15°C; ambient temperature 5°C; glycol 20% (5) Data refer to nominal conditions: recovery water temperature 40/45°C; chilled water temperature 12/7°C; ambient temperature 35°C; glycol 20%; refrigerant R407C (6) Data refer to empty unit C onstruc tion O p tions 05REF631A1A - v 1.2 • Exclusive free-cooling Uniflair system completely managed by the microprocessor control • Self-supporting frame in galvanised steel (colour RAL7037) with panels varnished with epoxy powders • Modulating condensation control with automatic regulation of fans speed • Four hermetic Scroll compressors with incorporated thermalprotection, with anti-vibration supports and crankcase heaters • Shell & tube evaporator insulated with closed-cell expanded neoprene • Condensing and free-cooling coils with alluminium fins and mechanically expanded copper tubes • Condensing coil protection filters and grilles • Axial fans, statically and dynamically balanced, with sickle-blades and with safety protection grilles • Two independent refrigerant circuits conforming to EC norms (PED 97/23/EC directive) in copper tubing including: filter dryer, flow indicator, thermostatic valves with external equalization, high & low pressure switches and high pressure transducers • Free-cooling pump regulated by microprocessor control • Electric panel conforming to EC norms (73/23/EC directive and EMC 89/336/EC directive) complete with anti-condensation heater, auxiliary circuit, general cut-off switch, magneto-thermal protection cut-off switches for compressors, fans and auxiliaries • Sequence phase control • Water flow differential pressure switch • Microprocessor control system UPC1m including: - local user terminal mP20 II visible on unit with panel - outlet chilled water temperature regulation - advanced management of compressors run throught automatic set-point sensitivity regulation - compressor rotation with FIFO system (run time, protection and function) ARAF MODEL • Low noise version with modulating condensation control through special algorithm and sound-proofing of compressor housing • Partial condensation heat recovery • Set-point adjustment from external signal 0-10V • Integrated hydronic system with 1 or 2 pumps (1 + 1 standby), reservoir tank, safety valves, expansion tank (each pump is equipped with a non-return valve and interceptive valve) • High and low pressure gauges • Power phase correction capacitors (compressors + fans + pump group) • Discharge interception valves on compressor • Sound-proofing of compressor housing • Clock card • RS485 serial adapter used to communicate with Uniflair supervision system or to interface with external BMS • Condensing coil cataphoresis treatment • R134a Refrigerant (*) (*) on request 27 BRAf - BRAm Technical D ata BRAF/BRAM MODELS Range: BRAF - free-cooling series Cooling capacity: 300 ÷ 720 kW BRAM - ultra-low noise free-cooling series Cooling capacity: 270 ÷ 610 kW BRAM - ultra low noise Refrigerant R407C/R134a* Scroll and double Screw Compressors S tandard F e atures 28 - local user terminal mP20 II visible on unit with panel - outlet chilled water temperature regulation - advanced management of compressors run (units equipped with Scroll compressors) or of 8 steps (units equipped with screw compressors) throught automatic set-point sensitivity regulation; compressor rotation with FIFO system (run time, protection and function) - monitoring of refrigerant charge (with E.E.V.) - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers - integrated clock card • Microprocessor control system with: - set-point adjustment from external signal 0-10V - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm management - remote ON-OFF switch - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP 1506A Free-cooling supersilenziato (BRAM) (ambient temperature max 42°C*) Cooling capacity (1) kW 271 300 326 Cooling capacity ECO (2) kW -- -- -- Absorbed power (1) kW 126.3 146.4 166.5 Absorbed power ECO (2) kW -- -- -- Cooling capacity in F. C. (4) kW 204.8 207.1 209.0 Absorbed power in F.C. (4) kW 12.6 12.6 12.6 Noise pressure level (3) dB(A) 52.0 52.0 52.0 Nr. of fans / Nr. of poles 6 / 6 6 / 6 6 / 6 Dimensions (BRAM) Height mm 2525 2525 2525 Length mm 4930 4930 4930 Width mm 2200 2200 2200 (1) Data refer to nominal conditions: water temperature 12/7°C; external temperature 35°C; glycol 20%; refrigerant R407C (2) Unit equipped with compressors with economiser, data refer to nominal conditions: water temperature 12/7°C; external temperature 35°C; refrigerant R407C (3) Measured in free field conditions, coil side, direction factor Q=2, at 10 mt. from the 1802A 2002A 2202A 2502A 2802A 3002A 357 383 171.0 175.3 275.0 17.8 52.5 8 / 6 389 436 481 526 574 417 462 514 558 610 175.2 216.5 240.6 296.1 302.6 179.9 222.1 246.0 304.7 311.8 275.4 278.8 343.9 347.2 350.3 17.8 17.8 19.4 19.4 19.4 52.5 52.5 53.5 53.5 53.5 8 / 6 8 / 6 10 / 6 10 / 6 10 / 6 2525 2525 2525 2525 2525 2525 6360 6360 6360 7785 7785 7785 2200 2200 2200 2200 2200 2200 unit (at nominal conditions) (4) Data refer to nominal conditions: inlet water temperature 15°C; external temperature 5°C; glycol 20% (*) For units with economiser max ambient temperature decreases of 2°C C onstruc tion O p tions O p tions Units can be supplied with the following construction options: • Remote user terminal mP20 II (up to 200 metres) for: - entering of commands - display unit status and alarms • Spring anti-vibration kit 05REF641A1A - v 1.1 • Exclusive free-cooling Uniflair system completely managed by the microprocessor control • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL7037) • Six hermetic Scroll compressors with internal thermal protection and anti-vibration supports (1206A ÷ 1506A models) • Two semi-hermetic Screw compressors with internal thermal protection, oil heater and anti-vibration supports (1802A ÷ 3002A models) • Two refrigerant circuits conforming to EC norms (PED 97/23/CE) in copper tubes mainly including: filter dryer, flow indicator, thermostatic valves with external equalisation (E.E.V. optional), discharge shut-off valve, high and low pressure switches and high and low pressure transducer • Oil heater on compressors • Shell & tube evaporator with two independent cooling side circuits and one hydraulic circuit: the heat exchanger is insulated with closed-cell expanded neoprene • Free-cooling coil with aluminium fins and mechanically expanded copper tube • Condensing coil with aluminium fins and internally grooved copper tubes • Water flow pressure switch • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles, protection grade IP54 • Modulating condensation control • Electric panel conforming to EC (Directive 73/23/EC and Directive EMC 89/336/EC, protection grade IP54) with anti-condensation heater, maximum internal temperature control, general cut-off switch, magneto-thermal protection for fans and auxiliaries, magneto-thermal protection for Scroll compressors and fuses for screw compressors, cut-off switches • Sequence phase monitor • Free-cooling pump regulated by microprocessor control • Microprocessor control system UPC1m including: 1306A Power supply V/ph/Hz 400 / 3 / 50 4 00 / 3 / 50 Compressors nr. x mod 6 x Scroll2 x Screw Evaporator nr. x mod 1 x Shell & Tube 1 x Shell & Tube Free-cooling (BRAF) - basic version (ambient temperature max 44°C*) Cooling capacity (1) kW 290 329 365 401 442 491 549 605 677 Cooling capacity ECO (2) kW -- -- -- 427 475 522 584 643 724 Absorbed power (1) kW 122.4 124.1 140.9 161.4 151.7 183.8 223.2 266.7 252.2 Absorbed power ECO (2) kW -- -- -- 164.6 154.1 186.7 226.9 272.8 257.4 Cooling capacity in F. C. (4) kW 199 286 291 295 381 388 395 400 493 Absorbed power in F.C. (4) kW 14.0 17.3 17.3 20.8 24.1 24.1 24.1 24.1 27.4 Noise pressure level (3) dB(A) 61.5 62.5 62.5 63.0 64.0 64.5 64.5 67.0 67.5 Nr. of fans / Nr. of poles 4 / 6 6 / 6 6 / 6 6 / 6 8 / 6 8 / 6 8 / 6 8 / 6 10 / 6 Free-cooling (BRAF) - Low noise version (ambient temperature max 41°C*) Cooling capacity (1) kW 261 303 336 365 407 452 495 543 607 Cooling capacity ECO (2) kW -- -- -- 389 438 482 527 576 649 Absorbed power (1) kW 132.3 135.7 151.1 174.8 160.4 198.2 239.0 294.0 272.9 Absorbed power ECO (2) kW -- -- -- 180.0 164.3 201.0 245.4 307.3 278.3 Cooling capacity in F. C. (4) kW 162.1 235.8 239.1 241.4 314.7 319.1 322.6 325.8 402.3 Absorbed power in F.C. (4) kW 11.9 14.1 14.1 17.6 19.8 19.8 19.8 19.8 22.0 Noise pressure level (3) dB(A) 55.0 56.0 56.0 56.0 56.5 57.0 57.0 57.0 57.5 Nr. of fans / Nr. of poles 4 / 6 6 / 6 6 / 6 6 / 6 8 / 6 8 / 6 8 / 6 8 / 6 10 / 6 Dimensions (BRAF) Height mm 2525 2525 2525 2525 2525 2525 2525 2525 2525 Length mm 3500 4930 4930 4930 6360 6360 6360 6360 7785 Width mm 2200 2200 2200 2200 2200 2200 2200 2200 2200 Air-cooled water chillers with free-cooling system and ultra-low noise free-cooling system Available versions: BRAF - basic - low noise 1206A • Economiser option: available only for models equipped with screw compressors: increases cooling capacity and COP • Low noise version: with sound-proofing of Scroll compressors or sound-proofed casing and low fan speed • Ultra low noise series (BRAM): with sound-proofing of Scroll compressors or sound-proofed casing and vibration absorbers for screw compressors and ultra low fan speed • Electronic expansion valve (E.E.V.) • Partial condensation heat recovery • Integrated hydraulic system with 1 or 2 pumps • High and low pressure gauges • Evaporator / pumps protection grilles • Suction shut-off valves on compressor • RS485 serial adaptor used to communicate with Uniflair supervisory system or to interface with external BMS • LON FTT10 serial adaptor used to communicate with external BMS managed with LON protocol • Condensing and free-cooling coil cataphoresis treatment (*) (*) on request 29 ²BRAF Technical D ata 3604A ²BRAF MODEL Air-cooled water chillers with free-cooling system Power supply Compressors / circuits Evaporator Nr. of fans / Nr. of poles Basic version Cooling capacity (1) Cooling capacity ECO (2) Absorbed power (1) Absorbed power ECO (2) Cooling capacity free-cooling (3) Absorbed power free-cooling (3) Noise pressure level (3) Low noise version Cooling capacity (1) Cooling capacity ECO (2) Absorbed power (1) Absorbed power ECO (2) Cooling capacity free-cooling (3) Absorbed power free-cooling (3) Noise pressure level (3) Dimensions Height Length Width Range: Cooling capacity: 800 ÷ 1350 kW Available versions: - basic - low noise Refrigerant R407C/R134a* Double Screw Compressors S tandard F e atures auxiliaries, fuses for compressors and cut-off switches • Sequence phase monitor • Free-cooling pump regulated by microprocessor control • Microprocessor control system UPC1m including: - local user terminal mP20 II visible on unit with panel - outlet chilled water temperature regulation - advanced 16 steps of the compressors management through automatic set-point sensitivity regulation; - compressor rotation with FIFO system (run time, protection and function) - monitoring of refrigerant charge (only with E.E.V.) - rotation of pump group setting functioning and start of pump in stand-by (alarm display) in the event of pump breakdown - advanced anti-freeze protection on evaporator - integrated LAN card for local network connection of a group of chillers (up to 5 units) - integrated clock card • Moreover microprocessor control system permits: - set-point adjustment from external signal 0 - 10V - management of double set-point and selection - free-contact for general alarm and 2 addressable alarm - management - remote ON-OFF switch - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP kW kW kW kW kW kW dB(A) kW kW kW kW kW kW dB(A) mm mm mm 12 / 6 16 / 6 802 884 854 950 323 303 329 308 590 762 42 48 66.0 67.0 730 814 778 876 350 321 360 329 483 629 35 40 59.0 59.5 2525 2525 9960 12820 2200 2200 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C; glycol: 20% (2) Unit equipped with economiser, Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C; glycol: 20% 4404A 5004A 5604A 6004A 400 / 3 / 50 4 x Screw / 4 2 x Shell & Tube 16 / 6 16 / 6 16 / 6 20 / 6 982 1044 368 373 776 48 67.5 1098 1168 446 454 790 48 67.5 1210 1286 533 546 800 48 70.0 1354 1448 504 515 986 55 70.5 904 964 396 402 638 40 60.0 990 1054 478 491 645 40 60.0 1086 1152 588 615 652 40 60.0 1214 1298 546 557 805 44 60.5 2525 12820 2200 2525 12820 2200 2525 12820 2200 2525 15670 2200 (3) Data refer to nominal conditions: inlet water temperature 15°C; ambient temperature 5°C; glycol: 20% (4) Measured in free field at 10 mt. (Q=2, coil side) from the unit running in nominal conditions C onstruc tion O p tions O ptions • Low-noise version: with sound-proofed casing and low fan speed • Electronic expansion valve (E.E.V.) • Economiser option: available only for models equipped with screw compressors increases cooling capacity and COP • Partial heat recovery • High and low pressure gauges • Integrated hydronic system with 1 or 2 pumps (1 + 1) • Evaporator / pumps protection grilles • Condensing coils equipped with safety grilles and filter • Suction shut-off valves on compressors • RS485 serial adaptor used to communicate with Uniflair supervisory system or to interface with external BMS • LON FTT10 serial adaptor used to communicate with external BMS managed with LON protocol • Condensing and free-cooling coil cataphoresis treatment (*) • R134a Refrigerant (*) Units can be supplied with the following construction options: • Remote user terminal mP20II (up to 200 metres) for: - entering of commands - display unit status and alarms • Spring anti-vibration kit (*) on request 05REF676X1A - v 1.1 • Exclusive free-cooling Uniflair system completely managed by the microprocessor control • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL7037) • Four semi-hermetic double Screw compressors with internal thermal protection, oil heaters and anti-vibration supports; moreover the compressors can be equipped with the Economiser (optional) • Four refrigerant circuits conforming to EC norms (PED 97/23/CE) in copper tubes mainly including: filter dryer, flow indicator, thermostatic valves with external equalisation (E.E.V. optional), discharge shut-off valve, high and low pressure switches and high and low pressure transducers • Two shell & tube evaporator with two independent cooling side circuits and one hydraulic circuit: the heat exchanger is insulated with closed-cell expanded neoprene • Condensing coil with aluminium fins and internally grooved copper tubes • Free-cooling coil with aluminium fins and mechanically expanded copper tube • Water flow pressure switch • Sickle-blade axial fans, statically and dynamically balanced with safety protection grilles, protection grade IP54 • Modulating condensation control by fan speed regulation • Double electric panel conforming to EC (Directive 73/23/EC and D i r ec t i v e E M C 8 9 / 33 6 / E C , p r o t ec t i o n gr ade I P 5 4 ) w i t h anti-condensation heater, maximum internal temperature control, general cut-off switch, magneto-thermal protection for fans and V/ph/Hz nr. x mod nr. x mod 4004A 30 31 CRCC - CRCH Technical D ata 0031A CRCC/CRCH MODELS Air-cooled water chillers and heat pumps with centrifugal fans for indoor installation V/ph/Hz Power supply Cooling only (CRCC) kW Cooling capacity (1) kW Absorbed power (1) Heat pump (CRCH) Heating capacity (2) kW Absorbed power (2) kW kW Heat recovery power (3) l/h Water flow Pressure drop kPa m³/h Airflow (4) Fan absorbed power kW Nr. of circuits / Nr. of compressors Water flow l/h Pressure drop evaporator kPa Available head pressure (5) kPa dB(A) Noise pressure level (6) l Water tank capacity Hydraulic connections chilled water Water connections recuperator Dimensions and weight mm Height Width mm Depth mm Weight (basic version) (7) kg Range: Cooling capacity: 7 ÷ 35 kW Heating capacity: 8 ÷ 41 kW Available versions: - basic - modulating condensation control Refrigerant R407C Scroll Compressor S tandard F e atures • Reduced footprint and easy front accessibility to all components • Intake and outtake of duct air • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL9001) in compliance with ASTM B117 • Hermetic scroll compressors with internal thermal protection and anti-vibration supports • Stainless steel brazed plate heat exchangers insulated with closed-cell expanded polyurethane • Heat exchangers with aluminium fins and mechanically-expanded copper tubes • Centrifugal fans, statically and dynamically balanced with safety protection grilles • Refrigerant circuit in compliance with EC norms (PED97/23/EC directive) including filter dryer, water flow indicator, thermostatic valves with external equalisation and high and low pressure switches, cycle inverter (CRCH) • Electric panel conforming to EC Directive 73/23/EC and Directive EMC 89/336/EC with auxiliary transformer 24V circuit, general cut-off switch , magneto-thermal protection cut-off switches • Differential pressure switch • Microprocessor controlling system including: - local user control and monitoring terminal with LCD display and LED signals for all working parameters - chilled water temperature regulation (also hot water for CRCH) - anti-freeze protection - compressor timing and protection - alarm code signalling - remote ON-OFF switch 4 00/3+N/50 0031B 0041A 950 1000 655 166 0061A 0081A 0091A 0121A 0161A 0191A 230/1/50 400/3+N/50 230/1/50 400/3+N/50 6.9 6.9 8.0 2.54 2.54 3.09 7.7 7.6 9.0 2.57 2.49 3.12 2.2 2.2 2.7 376 376 458 7.0 7.0 10.4 2490 2490 3070 0.30 0.30 0.37 1190 1190 1370 22 22 28 47 47 39 53.0 53.0 55.0 55 55 55 0041B 950 1000 655 166 (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (2) Data refer to nominal conditions: water temperature 40/45°C; ambient temperature 7°C dry bulb; 6°C wet bulb; refrigerant R407C (3) Data refer to nominal conditions: chilled water temperature 7/12°C; recovery water temperature 40/45°C; ambient temperature 35°C; refrigerant R407C 950 1000 655 170 8.0 3.08 11.9 4.50 16.3 6.60 17.2 7.66 23.3 9.57 30.6 35.5 13.30 15.05 9.0 13.0 18.4 19.7 27.0 34.8 41.0 3.08 4.24 6.56 6.84 8.85 11.78 13.39 2.7 4.0 5.6 5.8 8.4 10.1 12.0 458 686 964 997 1438 1732 2059 10.4 7.6 15.1 16.1 12.7 11.1 15.7 3070 4960 5640 6800 9290 12620 12470 0.37 0.52 1.13 1.65 1.70 2.67 2.63 1/1 1370 2050 2810 2950 4030 5260 6120 28 29 31 17 20 25 26 39 170 155 222 196 203 195 55.0 57.0 59.5 63.0 63.0 66.5 66.5 55 75 75 75 75 120 120 1 1/4” G.f. 1/2” G.f. 1”G.f. 1”G.f. 950 1000 655 170 1370 1350 790 260 1370 1350 790 320 1370 1350 790 333 1370 1350 790 400 1516 1700 820 450 1516 1700 820 503 (4) With 100 Pa head pressure (5) Available with standard pump group (6) Measured in free-field conditions at 1 mt. from the front of the unit (at nominal conditions) (7)Data refer to empty unit C onstruc tion O p tions • Integrated hydronic system with circulation pump, with safety valve and reservoir tank • Modulating condensation control through automatic fan speed regulation • Flange for intake/ discharge of condensed air • Safety protection filters on coil • Partial condensation heat recovery (CRCC only) • R22 refrigerant (available option on request according to UE 2037/2000 standards) • RS485 serial adapter used to communicate with Uniflair supervision system or to interface with external BMS • Cascade management of 2, 3 and 4 units installed on the hydraulic circuit • Version for the production of glycol water mixture at low temperatures (down to - 8 °C) only CRCC (*) • Evaporator and reservoir anti-freeze protection O ptions • Remote user terminal (up to 150 metres) for: - display / direct entering of commands - display unit status and alarms • Rubber anti-vibration kit • Spring anti-vibration kit 05REF561A1A - v 1.2 (*) on request 32 33 ARCC - ARCH Technical D ata 0182A ARCC/ARCH MODELS Air-cooled water chillers and heat pumps with centrifugal fans for indoor installations Power supply Cooling capacity (1) Absorbed power (1) Water flow Heat pressure (water circuit) std pump Nr. of circuits / Nr. of compressors Airflow (2) Noise pressure level (3) Thermal heat recovery (5) Water flow (5) Water tank capacity Dimensions and weight Height Depth Width Weight (basic version) (4) Range: Cooling capacity: 40 ÷ 100 kW­ Heating capacity: 50 ÷ 120 kW­ Available versions: - basic - low noise - high head pressure fans Refrigerant R407C Scroll compressors V/ph/Hz kW kW l/h kPa m³/h dB(A) kW l/h l mm mm mm kg 34 • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL9001) in compliance with ASTM B117 • Centrifugal fans coupled with an electric engine for speed regulation. Motor class H insulation and IP54 protection Standard fan group assure a 100 Pa available static pressure • If selected the unit can have a vertical air out-put upwards, or horizontal on the same intake side • Hermetic scroll compressor with incorporated thermal protection and anti-vibration supports • Stainless steel brazed plate two-circuit evaporators that enable increased COP ratings at partial load • Condensing coils with aluminium fins and mechanically-expanded copper tubes, with integrated cooling • Two refrigerant circuits conforming to EC Directives (PED 97/23/ EC directive) including: filter dryer, flow indicator, thermostatic valves with external equalisation and high & low pressure switches • Electric panel conforming to EC Directive 73/23/EC and Directive EMC 89/336/EC with auxiliary transformer 24V circuit, general door lock switch, magneto-thermal protection cut-off switches • Sequence phase control • Water flow differential pressure switch • Microprocessor control system including: local user control and monitoring terminal with LCD display and LED signals for all working parameters - chilled water temperature regulation - anti-freeze protection - compressor timing and protection - compressor function display - alarm code signalling and centralisation for general alarm control transmission - remote ON-OFF switch • Remote user terminal (up to 150 meters) for: - display / changing set points - display unit status and alarms • Remote user terminal mP20 II (up to 200 meters) for: - display / changing set points - display unit status and alarms • Rubber anti-vibration kit • Soundproofing discharge plenums • Soundproofing intake plenums 0252A 0302A 0402A 0502A 1880 984 2104 595 1880 984 2104 615 1880 984 2104 650 1880 984 2104 670 1880 984 2104 690 1880 984 2504 850 1880 984 2504 880 (4) Data refer to empty unit (5) Data refer to nominal conditions: chilled water temperature 7/12°C; recovery water temperature 40/45°C; ambient temperature: 35°C; Refrigerant R407C Available pump groups (option) A (1.34 kW) B (1.50 kW) C (2.36 kW) 0182 / 0202 0232 / 0252 / 0302 opz. opz. opz. n.d. opz. opz. 0402 / 0502 n.d. n.d. opz. opz.= option; n.a.= not available C onstruc tion O p tions • ARCH heat pumps series (*) • Modulating condenser head pressure control through automatic fan speed regulation (modulating control includes heat exchangers for compressors) • ARCH series heat pumps (*) • Low-noise version and modulating condenser head pressure control • Ul tra-low noise version equipped wi th soundproofing plenums (option) • Centrifugal pitch pulley fans with variable speed, units assure a 150 Pa available external static pressure • High capacity pitch pulley fans with variable speed units and high ESP up to 300 Pa (not for ARCC0402 / ARCC0504) • Integrated hydronic system with 1 or 2 pumps (1 + 1 standby), expansion tank, safety valve, reservoir tank • Partial condensation heat recovery and modulating condenser head pressure control • Advanced mP20 II microprocessor controlling system with single management of all capacity steps • Electronic expansion valve (E.E.V.) (*) • Discharge temperature control • RS4 85 serial adapter used to communicate with Uniflair supervision system or a link-board Modbus RTU to interface with external BMS • LAN card for the local network connection mP20 II control • Cascade management ready for 2, 3 or 4 units installed on a parallel hydraulic circuit connection (only std control) • High and low refrigerant pressure gauges • Version for the production of glycol water mixture at low temperatures (down to - 8 °C) (*) • Compressor power phase correction capacitors • Anti-freeze protection on evaporator, reservoir tank • Coil protection metal filters and grilles • Flange for air intake duct • R22 refrigerant (available on request according to Reg. UE 2037/2000 standards) • R134a refrigerant (*) (*) on request 05REF571A1A - v 1.1 O p tions 0232A 400 / 3 + N / 50 43.5 49.5 57.4 63.8 73.4 88.5 99.3 18.16 20.51 24.81 28.43 33.38 37.66 46.20 7490 8530 9880 10980 12640 15230 17100 204 185 166 161 155 179 166 2 / 2 14050 14050 17340 17340 20380 28940 28940 52.5 52.5 56.5 56.5 58.5 60.5 60.5 15.1 17.8 20.2 22.5 27.0 30.9 36.1 2597 3062 3475 3870 4644 5315 6210 240 240 240 240 240 240 240 (1) Data refers to nominal conditions: water temperature 7/12°C; ambient temperature 35°C; refrigerant R407C (2) With 100 Pa head pressure (3) Measured in free-field conditions at 1 mt. from the front of the unit at nominal conditions (version with sound absorbing plenum or ducted) S tandard F e atures 0202A 35 ARWC - ARWH Technical D ata Power supply Cooling only (ARWC) Cooling capacity (1) Absorbed power (1) Nr. of circuits / Nr. of compressors Water flow evaporator Water flow condenser Pressure drop evaporator Available head pressure (evaporator) Noise pressure level (4) Hydraulic connections in/out Partial heat recovery (2) Water flow (2) Pressure drop (2) Heat pump (ARWH) Heating capacity (3) Absorbed power (3) Nr. of circuits / Nr. of compressors Water flow evaporator Water flow condenser Pressure drop evaporator Available head pressure (evaporator) Noise pressure level (4) Hydraulic connections in/out Dimensions and weight Height Width Depth Weight (basic version) (5) Range: Cooling capacity: 50 ÷ 110 kW­ Heating capacity: 57 ÷ 132 kW­ Available versions: - basic - condensation control Refrigerant R407C Scroll compressors O p tions • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL9001) in compliance with ASTM B117: protection grade IP44 • Hermetic scroll compressors with internal thermal protection and anti-vibration supports • Crankcase heaters (ARWH) • Stainless steel brazed plate heat exchangers insulated with closed-cell expanded polyurethane • Exchange of the cycle on the refrigerant side with 4-way reversing valve (ARWH) • Two refrigerant circuits in compliance with EC norms (PED 97/23 / EC directive) including filter dryer, water flow dryer, thermostatic valves with external equalisation and high and low pressure switches • Electric panel conforming to EC Directive 73/23/EC and Directive EMC 89/336/EC with auxiliary transformer 24V circuit, general door lock switch, magneto-thermal protection cut-off switches • Sequence phase control • differential pressure switch • Microprocessor controlling system including: - local user control and monitoring terminal with LCD display and LED signals for all working parameters - chilled water temperature regulation (and hot water on ARWH) - anti-freeze protection - compressor timing and protection - compressor function display - alarm code signalling and centralisation for general alarm control transmission - remote ON-OFF switch Units can be supplied with the following construction options: • External pump groups supplied by Uniflair with 1 or 2 pumps (1 + 1 in stand-by) including: expansion tank safety valve: motor guarantees IP55 protection • External reservoir tank • Remote user terminal (up to 150 meters) for: - display / entering of commands - display unit status and alarms • Remote user terminal mP20 II (up to 200 meters) • Rubber anti-vibration kit 36 V/ph/Hz kW kW l/h l/h kPa kPa dB(A) kW l/h kPa kW kW l/h l/h kPa kPa dB(A) mm mm mm Kg 0202A 0232A 0252A 0302A 0403A 0504A 400 / 3 + N / 50 46.5 54.9 62.4 12.71 14.23 17.06 2 / 2 2 / 2 2 / 2 7990 9470 10750 10260 11990 13770 25 28 30 193 162 158 50.5 51.0 52.5 12.1 13.5 16.2 2080 2330 2790 15 7 10 71.4 18.92 2 / 2 12880 15660 32 148 54.5 2” gas f. 18.0 3100 9 82.6 21.63 2 / 2 14220 18070 31 140 55.5 97.8 24.01 2 / 3 16830 21110 28 160 56.0 112.3 26.41 2/4 19330 24050 45 135 56.0 20.5 3540 11 22.8 3930 13 25.1 4320 12 87.0 23.17 2 / 2 10980 15140 26 161 54.5 2” gas f. 100.2 26.5 2 / 2 12670 17420 25 155 55.5 116.6 29.61 2 / 3 14900 20210 30 179 56.0 132.3 32.71 2/4 17140 23010 36 160 56.0 390 460 530 57.1 66.5 76.7 15.05 17.59 20.38 2 / 2 2 / 2 2 / 2 7240 8420 9700 9920 11560 13350 21 23 25 210 187 168 50.5 51.0 52.5 320 330 350 (1) Data refer to nominal conditions: chilled water temperature 7/12°C; condenser inlet/ outlet water temperature 30/35°C; refrigerant: R407C (2) Data refer to nominal conditions: chilled water temperature 7/12°C; recovery water temperature 45/40°C; condenser inlet / outlet water temperature 30/35°C; refrigerant R407C 1452 1191 905 360 (3) Data refer to nominal conditions: evaporator inlet/outlet water temperature 40/45°C; Condenser inlet/outlet water temperature 7/12°C; refrigerant R407C (4) Misured in free field conditions at 1 mt., from the front of the unit (at nominal conditions) (5) Data refer to empty unit Available water tank (external) Available pump groups (external) ARWC/ARWH 0182A 0202A 0232A 0252A 0302A A (1.34 kW) B (1.50 kW) C (2.35 kW) opz. opz. opz. opz. opz. opz. n.d. opz. opz. n.d. opz. opz. n.d. opz. opz. 0403A 0504A n.d. n.d. opz. n.d. n.d. opz. opz.= option; n.a.= not available ARWC/ARWH 0182A 0202A 0232A 0252A 0302A A (210 l) B (300 l) C (500 l) opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. 0403A 0504A opz. opz. opz. opz. opz. opz. opz.= option; n.a.= not available C onstruc tion O p tions 05REF551A1A - v 1.0 S tandard F e atures 0182A ARWC/ARWH MODELS Water-cooled water chillers and heat pumps with centrifugal fans for indoor installations • Modulating condenser head pressure control through pressostatic valves • Low noise version and condensation pressure control version • Prearrangement of the external Uniflair pump group • Partial condensation heat recovery and control of condensation pressure (ARWC) • Microprocessor mP20 II (ARWC only) • Electronic expansion valve (ARWC only) (*) • RS485 serial adapter used to communicate with Uniflair supervision system or to interface with external BMS • LAN card for local network connection mP20 II (ARWC) • Cascade management ready for 2, 3 or 4 units installed on a parallel hydraulic circuit connection (only standard controls) • High and low pressure gauges • Production of glycol water mixture at low temperatures (up to - 8 °C) (*) • Compressor power phase correction capacitors • Compressor crankcase heaters (standard for ARWH) • R22 refrigerant (available on request according to UE 2037/2000 standards) • R134a refrigerant (*) (*) on request 37 BRWC - BRWH Technical D ata Power supply Compressors Evaporator Condensers Cooling only (BRWC) Cooling capacity (1) Absorbed power (1) IPLV (3) ESEER (4) Heat pump (BRWH) Heating capacity (2) Noise levels Noise pressure level basic version (5) Noise pressure level LN version (5) Dimensions and weight Height Length Width Width with heat recovery Weight (6) Range: Cooling capacity: 300 ÷ 1200 kW Heating capacity: 370 ÷ 1370 kW Available versions: - basic - sea water condersers - high condensing water temperature (**) R134a Refrigerant Double Screw Compressors 38 V/ph/Hz nr. x mod nr. x mod nr. x mod 400 / 3 + N /50 2 x Semi-hermetic double screw 1 x Shell & Tube 2 x Shell & Tube kW kW 330 71.8 5.10 4.78 389 82.2 5.52 5.11 430 96.9 5.00 4.67 476 100.2 5.52 5.11 544 116.6 5.88 5.35 631 131.5 5.50 5.08 712 146.0 5.68 5.26 830 172.8 5.63 5.15 kW 377 440 494 541 627 715 806 938 1091 1216 1368 dB(A) dB(A) 73.5 64.0 73.7 63.9 73.8 64.6 78.0 68.5 79.5 69.6 79.7 68.7 79.6 72.4 77.3 69.3 75.3 69.1 76.3 71.8 78.4 72.5 mm mm mm mm kg 2050 3660 860 1680 2815 2050 3660 860 1680 2865 2050 3660 860 1680 2930 2050 3800 860 1680 3649 2050 3800 860 1680 3707 2060 4070 860 1755 3747 2060 4070 860 1755 3818 2295 4130 1485 1660 5360 2295 4130 1485 1660 5481 2295 4130 1485 1660 5638 2295 4130 1485 1660 5719 (1) Data refer to nominal conditions: Evaporator in/out water temperature: 12/7°C; Condenser in/out water temperature: 30/35°C; condenser fouling coefficient: 0,000043 m²°C/ W; evaporator fouling coefficient: 0,000043 m²°C/ W; R134a refrigerant (2) Data refer to nominal conditions: Evaporator in/out water temperature: 12/7°C; Condenser in/out water temperature: 40/45°C; condenser fouling coefficient: 0,000043 m²°C/ W; evaporator fouling coefficient: 0,000043 m²°C/ W; R134a refrigerant S tandard F e atures • The microprocessor control system also includes: - external evaporator pump group management - set point adjustment from external 0-10V signal - double set-point management with contact selection - general alarm contact and 2 addressable alarms - ON-OFF remote control - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP 954 1077 1204 196.3 225.9 249.0 6.03 5.50 5.63 5.45 5.03 5.20 (3) Integrated Partial Load Value: based on ARI conditions (4) European Seasonal Energy Efficiency Ratio (5) Measured in free field with Q =2 directionality factor, at a distance of 1 mt. from the unit (6) Data refer to basic versions without load C onstruc tion O p tions • Low noise version with sound proofed housing for the compressors • Low external temperature version with anti- condensation heater for the electrical panel and heaters for the evaporator and condensers • Modulating condensation control version with 2-way valve (external kit) • Condensers for sea water • High condensation temperature version • Partial / total integrated condensation heat recovery O p tions • Pressostatic valve with integrated control for control software • Remote control panel which allows: - display / modification of settings - display of activated alarms • Spring anti-vibration anti-seismic supports • Neoprene anti-vibration supports. • Low temperature glycol water mixture production (to -10°C) • RS485 serial card for connection to the Uniflair supervision system or an external BMS • LON FFT10 serial card for connection to an external BMS with LON protocol • Power phase correction condensers • Unit predisposed for outdoor installation (*) (*) on request (**) available only for 1402A, 2002A, 2022A, 3202A, 3602A models 05REF688X1A - v 1.0 • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL7037) • Two semi-hermetic double screw compressors with internal thermal protection, oil heaters and anti-vibration supports • Two refrigerant circuits conforming to EC standards (PED 97/23/ CE) in copper tubing including: filter dryer, liquid sight glass, electronic expansion valve, discharge shut-off valve, pressure gauges, pressure switches and high and low pressure transducers • Shell & Tube evaporator insulated with closed-cell expanded neoprene • Shell & Tube condenser • Water flow differential pressure switch for the evaporator and condensers • Electric panel conforming to EC standards (73/23/CE and EMC 89/336/CE directives) with maximum internal temperature control, auxiliary transformer, auxiliary general cut off switch, fuses for compressors, cut off switches • Phase sequence and min / max voltage control • UPC1m microprocessor control system including: - mP20II local user terminal visible externally and accessible through a door panel - chilled water / hot discharge water temperature regulation - advanced start-up management with 8 partialization steps with automatic set-point regulation and compressor rotation with FIFO logic (run time counter, inrush counter and counter threshold for programmed maintenance) - advanced evaporator anti-freeze protection - integrated L AN card for connection to the local network of a group of chillers (up to 10 units with one or two in reserve) - modulating condensation control (with kit: see options) - clock card 1402A 1602A 1802A 2002A 2202A 2502A 2802A 3202A 3602A 4202A 4802A BRWC/BRWH MODELS Water cooled water chiller and heat pump 39 BCWC Technical D ata BCWC MODEL Water-cooled water chillers for indoor installation Power supply Compressors Evaporator Condensers Cooling only (BRWC ) Cooling capacity (1) EER (1) IPLV (2) ESEER (3) Noise levels Noise pressure level (4) Dimensions and weight Height Length Width Weight (5) Range: Cooling capacity: 300 ÷ 1300 kW Available versions: - basic - sea water condersers (*) R134a refrigerant “oil-free” centrifugal compressors with magnetic bearings V/ph/Hz nr. x mod nr. x mod nr. x mod 0320A 0630A 0950A 1252A 400 / 3 /50 1 x centrifugal 2 x centrifugal 3 x centrifugal 4 x centrifugal 1 x flooded 1 x Shell & Tube kW kW 320 5.32 9.96 9.61 630 5.24 9.80 8.90 950 5.32 9.92 9.57 1250 5.34 9.87 9.53 dB(A) 67.3 70.3 72.1 73.3 mm mm mm kg 2015 2550 980 1585 2115 2950 1015 2814 2380 3300 1400 3752 2380 4850 1400 5760 (1) Data refers to nominal conditions: In/out evaporator water temperature: 12/7°C; In/ out condenser water temperature: 30/35°C; Condenser fouling coefficient: 0,000043 m²°C/W; Evaporator fouling coefficient: 0,000043 m²°C/W; R134a refrigerant (2) Integrated Partial Load Value: based on ARI conditions (3) European Seasonal Energy Efficiency Ratio (4) Measured in free field with Q=2 directional factor, at a distance of 1 mt. from the unit (5) Data refers to unloaded units O p tions C onstruc tion O p tions S tandard F e atures 40 • UPC3m microprocessor control system including: - continuous control of the cooling capacity by means of an inverter and IGV (Inlet Guide Vane) - PGD local user terminal with external display - outlet water temperature regulation - integrated LAN card for connecting more than one unit to the local area network - clock card • The control system also features: - external pump group management for the evaporator - set-point modification by an external 0-10V signal - management of a double set-point with contact selection - general alarm contact and 2 addressable alarms - remote ON-OFF control - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, Lonworks, Metasys, TCP/IP and SNMP • Remote control panel which enables: - the settings to be displayed / changed - alarm status to be displayed • Neoprene anti-vibration supports • Condenser for sea water use (*) • RS485 serial card for connection to Uniflair Supervision system or an external BMS • LON FFT10 serial card for connection to an external BMS with LON protocol (*) on request 05REF690X1A - v 1.0 • Self supporting metal frame in galvanised steel varnished in epoxy powders (colour RAL7037) • Between one and four “oil free” centrifugal compressors with magnetic bearings equipped with: - internal thermal protection - protection and control of the rotation axis position - brushless synchronized DC motor - integrated control system - speed control with inverter - soft start start-up - phase sequence control - pre-rotation valve - temperature and pressure sensors -2 centrifugal compressor stages - anti-vibration supports • Single refrigerant circuit conforming to EC standards (PED 97/23/ CE) with copper tubing including: filter dryer, liquid sight glass, electronic expansion valve controlled by a level sensor, discharge and suction taps on the compressor, pressure switches, high and low pressure transducers and gauges • By-pass line for vacuum start-up with high pressure ratio • Shell & Tube evaporator featuring an integrated de-mister to prevent the formation of droplets: the exchanger is insulated with closed-cell expanded polyurethane • Differential water pressure switch for the evaporator and the condenser • Shell & Tube condenser • Electric panel conforming to EC standards (73/23/EC and EMC 89/336/EC directives) with EMC integrated filter for protection of the harmonics, maximum internal temperature control, auxiliary transformer, general auxiliary cut-off switch, fuses on the compressors and remote control cut-off switches • Line reactance for each compressor to stabilize the power supply • Phase sequence control and minimum / maximum power supply and voltage 41 ARRC Technical D ata 0182A ARRC MODEL Power supply Cooling capacity (1) Absorbed power (1) Nr. of circuits / Nr. of compressors Condenser Partial heat recovery (2) Water flow (2) Pressure drop (2) Water flow evaporator Airflow Pressure drop evaporator Available head pressure (evaporator) Noise pressure level (3) Hydraulic connections inlet/outlet Dimensions and weight Height Width Depth Weight (basic version) (4) Condenserless chiller unit for indoor applications Range: Cooling capacity: 50 ÷ 100 kW­ Available versions: - basic - low noise Refrigerant R407C Scroll Compressors mm mm mm kg 305 310 325 ARRC 0182A A (1.34 kW) B (1.50 kW) C (2.35 kW) 0202A 0232A 0252A 0302A 0403A 0504A opz. opz. opz. opz. n.d. opz. n.d. opz. n.d. opz. n.d. n.d. n.d. n.d. opz. opz. opz. opz. opz. opz. opz. opz.= option; n.a.= not available 05REF541A1A - v 1.0 0252A 0302A 0403A 0504A 1452 1191 905 335 360 425 490 (3) Measured in free-field conditions at 1 mt. from the front of the unit (at nominal conditions) (4) Data refer to empty unit Available water tank (external) Available pump groups (external) • Sequence phase control • Water flow differential pressure switch • Microprocessor control system including: local user control and monitoring terminal with LCD display and LED signals for all working parameters - chilled water temperature regulation - anti-freeze protection - compressor timing and protection - compressor function display - alarm code signalling and centralisation for general alarm control transmission - remote ON-OFF switch Remote condenser (CAL) 42 nr. x mod kW l/h kPa l/h l/h kPa kPa db(A) 0232A 400 / 3 + N / 50 43.3 49.4 57.1 63.3 74.7 86.5 96.0 16.33 19.62 22.52 26.51 29.15 34.26 40.27 2/2 2/2 2/2 2/2 2/2 2/3 2/4 2xCAL0801 2xCAL0801 2xCAL1011 2xCAL1011 2xCAL1301 2xCAL3002 2xCAL3002 12.1 13.5 16.2 18.0 20.5 22.8 25.1 2080 2330 2790 3100 3540 3930 4320 15 7 10 9 11 13 12 7450 8500 9830 10910 12850 14890 16520 18990 18990 18090 18090 23630 31200 31200 22 23 25 26 26 30 34 205 186 167 162 153 180 166 50.5 51.0 52.5 54.5 55.5 56.0 56.0 2” gas f. (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; refrigerant R407C (2) Data refer to nominal conditions: chilled water temperature 12/7°C, recovery water temperature 40/45°C; ambient temperature 35°C; refrigerant R407C S tandard F e atures • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL9001) in compliance with ASTM B117 • Motor protection grade IP44 • Hermetic scroll compressor with incorporated thermal protection and anti-vibration supports • Stainless steel brazed plate heat exchangers insulated with closed-cell expanded polyurethane • Two refrigerant circuits conforming to EC Directives (PED 97/23/ EC directive) including: filter dryer, flow indicator, thermostatic valves • Electric panel conforming to EC Directive 73/23/EC and Directive EMC 89/336/EC with auxiliary transformer 24V circuit, general door lock switch , magneto-thermal protection cut-off switches V/ph/Hz kW kW 0202A ARRC 0182A 0202A 0232A 0252A 0302A 0403A 0504A A (210 l) B (300 l) C (500 l) opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz. opz.= option; n.a.= not available C onstruc tion O p tions O ptions • Low-noise version • Management of Uniflair pump group to be installed externally for ARRC • Microprocessor control advanced mP20 II • Electronic expansion valve (*) • RS485 serial adapter used to communicate with Uniflair supervision system or to interface with external BMS • LAN card for the local network connection mP20 II control (only ARRC) • Cascade management ready for 2, 3 or 4 units installed on a parallel hydraulic circuit connection (only with standard control) • High and low refrigerant pressure gauges • Version for the production of glycol water mixture at low temperatures (down to - 8 °C) (*) • Compressor power phase correction capacitors • R22 Refrigerant (available on request according to Reg. UE 2037/2000 standards) • R134a Refrigerant (*) • External Uniflair pump groups with 1 or 2 circulation pumps (1 + 1 in stand-by), reservoir tank, safety valves: pump motor IP55 • External reservoir tank • Remote user terminal (up to 150 meters) for: - display / changing set points - display unit status and alarms • Remote user terminal mP20 II (up to 200 meters) for: - display / changing set points - display unit status and alarms • Rubber anti-vibration kit (*) on request 43 BRRC Technical D ata 1402A 1602A 1802A 2002A 2202A 2502A 2802A 3202A 3602A 4202A 4802A BRRC MODEL Condenserless chiller with remote condenser Power supply Compressors Evaporator Cooling capacity (1) Absorbed power (1) EER Noise Levels Noise pressure level basic version (2) Noise pressure level LN version (2) Dimensions and weight Height Length Width Weight (3) Range: Cooling capacity: 300 ÷ 1200 kW Available versions: - basic - high condensing water temperature (**) R134a Refrigerant Double Screw Compressors V/ph/Hz nr. x mod nr. x mod kW kW 400 / 3 /50 2 x Semi Hermetic Double Screw 1 x Shell & Tube 284 336 377 414 482 551 630 726 842 938 1069 88.7 100.3 115.5 122.2 143.9 159.0 176.3 208.3 244.0 272.0 299.8 3.21 3.36 3.26 3.39 3.35 3.46 3.57 3.49 3.45 3.45 3.57 dB(A) dB(A) 73.5 64.0 73.7 63.9 73.8 64.6 78.0 68.5 79.5 69.6 79.7 68.7 79.6 72.4 77.3 69.3 75.3 69.1 76.3 71.8 78.4 72.5 mm mm mm kg 2010 3700 850 2335 2010 3700 850 2385 2010 3700 850 2420 2010 3700 850 3139 2010 3700 850 3159 2010 3900 850 3191 2010 3900 850 3212 1870 4130 1400 4616 1870 4130 1400 4737 1870 4130 1400 4858 1870 4130 1400 4939 (1) Data refer to nominal conditions: Evaporator in/out water temperature: 12/7°C; Condenser temperature: 50°C; Evaporator fouling coefficient: 0,000043 m²°C/W; R134a refrigerant S tandard F e atures condenser • The microprocessor control system also includes: - external evaporator pump group management - set point adjustment from external 0-10V signal - double set-point management with contact selection - general alarm contact and 2 addressable alarm - ON-OFF remote contact - ability to interface with main external communication protocols: Modbus, Bacnet, Lonworks, Trend, Metasys, TCP/IP and SNMP receiver O p tions BRRC • Remote control panel which allows: - display / modification of settings - display of activated alarms • Spring anti-vibration supports • Neoprene anti-vibration supports evaporator C onstruc tion O p tions 05RERF692X1A - v 1.0 • Self-supporting frame in galvanised steel with panels finished in epoxy powders (colour RAL7037) • Two semi-hermetic double screw compressors with internal thermal protection, oil heaters and anti-vibration supports • Two refrigerant circuits conforming to EC standards (PED 97/23/ CE) in copper tubing including: filter dryer, liquid sight glass, electronic expansion valve, discharge shut-off valve, pressure gauges, pressure switches and high and low pressure transducers. • Shell & Tube evaporator insulated with closed-cell expanded neoprene • Evaporator water flow pressure switch • Electric panel conforming to EC standards (73/23/CE and EMC 89/336/CE directives) with maximum internal temperature control, auxiliary transformer, general cut off switch, fuses for compressors, cut off switches • Phase sequence and min / max voltage control • UPC1m microprocessor control system including: - mP20II local user terminal visible externally and accessible through a door panel - outlet chilled water temperature - advanced start-up management with 8 partialization steps with automatic set-point regulation and compressor rotation with FIFO logic (run time counter, inrush counter and counter threshold for programmed maintenance) - advanced evaporator anti-freeze protection - integrated L AN card for connection to the local network of a group of chillers (up to 10 units with one or two in reserve) - clock card 44 (2) Measured in free field with Q=2 directionality factor, at 1 mt. from the unit (3) Data refer to a basic version empty unit • Low-noise version with sound proofed housing for the compressors • Low temperature water production (to -10°C) • RS485 Serial card for connection to the Uniflair supervision system or an external BMS • LON FFT10 serial card for connection to an external BMS with LON protocol • Power phase correction condensers • Unit predisposed for outdoor installation (*) (*) on request (**) available only for 1402A, 2002A, 2022A, 3202A, 3602A models 45 EPAC - EPAF Technical D ata EPAC Multifunctional air-cooled water chiller units with axial fans for outdoor installations Power supply Compressors / circuits Evaporator Nr. of fans / Nr. of poles Basic version Nr. of fans / Nr. of poles Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Cooling capacity - water / water mode (3) Heating capacity - water / water mode (3) Absorbed power - water / water mode (3) Cooling capacity free-cooling (4) Absorbed power free-cooling (4) Noise pressure level (5) Low noise version Nr. of fans / Nr. of poles Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Cooling capacity - water / water mode (3) Heating capacity - water / water mode (3) Absorbed power - water / water mode (3) Cooling capacity free-cooling (4) Absorbed power free-cooling (4) Noise pressure level (5) High external temperature operation version Nr. of fans / Nr. of poles Cooling capacity (1) Absorbed power (1) Heating capacity (2) Absorbed power (2) Cooling capacity - water / water mode (3) Heating capacity - water / water mode (3) Absorbed power - water / water mode (3) Noise pressure level (5) Dimensions Water tanks Height Length Width Range: Cooling capacity: 50 ÷ 100 kW Available series: - air & water-cooled series (EPAC) - air & water-cooled series with free-cooling device (EPAF) Available versions: - basic - low noise Refrigerant R407C Scroll Compressors S tandard F e atures 46 • Free-cooling pump managed by microprocessor control • Water flow differential pressure switch • Statically and dynamically balanced axial fans, with sickle-blades and safety protection grilles (protection grade IP54) • Condensation control, including continuous fan speed regulation • Electric panel conforming to Directives 73/23/EC and EMC 89/336/ EC (IP54 protection degree), auxiliary circuit, general cut-off switch, magneto-thermal protection cut-off switches • Sequence phase control • UPC1m microprocessor control system including: - mP20II local user terminal with panel visible on unit - outlet chilled water temperature regulation - advanced compressor management run throught automatic set-point sensitivity regulation - compressor rotation with FIFO system (run time, protection and function) - intelligent defrost management by means of hot gas solenoid valve for minimising defrost times - advanced anti-freeze prootection on evaporator - integrated LAN card for local network connection of a group of chillers (up to 10 units with 1 or 2 units on stand-by) • Moreover the microprocessor control system permits: - set-point adjustment from external signal (0-10V) - management of double set-point and selection -2 addressable alarm management - remote ON-OFF switch - ability to interface with Modbus protocol directly on RS485 serial card - ability to interface with main external communication protocols: Bacnet, LonWorks, Trend, Metasys, TCP/IP and SNMP V/ph/Hz nr. x mod nr. x mod (1) Data refer to nominal conditions: water temperature 12/7°C; ambient temperature 35°C; R407C refrigerant (2) Data refer to nominal conditions: water temperature 40/45°C; ambient temperature 7°C d.b. 6°C w.b.; R407C refrigerant (3) Data refer to nominal conditions: cool circuit water temperature 7/12°C; heat circuit 05REF681X1A - v 1.2 • The EPAC/F series units have been specially studied and designed for 4 tube or 2 tube systems where there is the need for a domestic hot water supply. They provide for producing hot and cold water contemporaneously in two separate circuits, regardless of the outdoor temperature. Moreover the units provide for producing hot or cold water depending on the needs. A 4 tube user system must be provided. The microprocessor control will automatically manage the operation mode in order to satisfy the load in the most energetically efficient manner • EPAF series units are fitted with a free-cooling device, completely managed by the microprocessor control. When part of the system is being used for technological systems with a continuous demand for chilled water, free-cooling operation leads to a considerable saving in electric consumption • Self-suppor ting, galvanised steel frame, and panels with an (colour RAL7037) epoxy powder finish • Two hermetic Scroll compressors with internal thermal protection, crankcase heaters and anti-vibration supports • One cooling circuit conforming to EC norms (PED 97/23 /CE) in copper tubes including : filter dr yer, filter shut-of f valve, flow indicator, thermostatic valves with external equalisation, Electronic Expansion Valve, high and low pressure switches and high pressure transducer • “SOF T” inversion chilling side cycle with the aid of solenoid valves, without 4 way inversion valve • Stainless steel brazed plate heat exchanges insulated with closed-cell expanded polyurethane • Heat exchanger coil with aluminium fins and internally grooved copper tubes • Free-cooling coils with aluminium fins and mechanically expanded copper tubes 0251A EPAC/EPAF MODELS kW kW kW kW kW kW kW kW kW dB(A) kW kW kW kW kW kW kW kW kW dB(A) kW kW kW kW kW kW kW dB(A) nr./lt mm mm mm 0501A EPAF 0251A 0501A 400 / 3 / 50 2/1 Plate 1 / 6 2 / 6 400 / 3 / 50 2/1 Plate 2 / 6 3/6 1 / 6 48.8 18.8 56.3 18.9 48.9 65.9 17.0 - - 55.5 1 / 6 47.1 19.5 54.8 18.3 48.9 65.9 17.0 - - 46.5 2 / 6 49.6 20.1 57.7 20.7 48.9 65.8 17.0 47.5 2 / 210 1618 3807 1193 2 / 6 106.1 38.6 123.7 37.2 108.7 142.6 33.9 - - 57.0 2 / 6 49.5 20.0 57.2 20.6 48.9 65.9 17.0 35.8 4.3 56.5 3/6 107.1 40.2 125.6 39.1 108.7 142.6 33.9 96.7 7.6 58.0 2 / 6 102.8 39.4 120.9 36.0 108.7 142.6 33.9 - - 48.0 2 / 6 48.3 19.8 55.8 19.5 48.9 65.9 17.0 29.7 3.1 47.5 3/6 105.7 39.1 123.2 37.2 108.7 142.6 33.9 84.3 5.8 49.0 3 / 6 109.7 39.0 127.9 39.1 108.7 142.6 33.9 49.0 - - - - - - - - - - 2 / 500 2140 5242 1344 2 / 210 1618 3807 1193 2 / 500 2140 5242 1344 water temperature 40/45°C; R407C refrigerant (4) Data refer to nominal conditions: inlet water temperature 15°C; ambient temperature 5°C; R407C refrigerant; glycol: 20% (5) Measured in free field at 10 mt. (Q=2, coil side) from the unit running in nominal conditions in Chiller mode (1) C onstruc tion O p tions O ptions • Low noise version • High external temperature operation version (EPAC) • Integrated hydronic system with 2 water tanks and 2 pumps • High head pressure pump group • Anti-freeze protection on evaporator, water tanks and pump group • Heat exchange coil equipped with safety grilles and filter • Inlet shut-off valve for compressors • RS4 85 serial adaptor used either to communicate with Uniflair supervision system or interface with external BMS Units can be supplied with the following accessories: • mP20II remote user terminal (max. 200 metres) for: - entering commands - displaying unit status and alarms • Spring anti-vibration kit 47 FKCM Technical D ata FKCM MODEL Cooling capacity (1) kW Sensibile cooling capacity (1) kW Water flow (cooling) (1) l/h Absorbed power (1) W Heating capacity (2) kW Water flow (heating) (2) l/h Airflow (4) m³/h Noise pressure level (3) Speed 1 dB(A) Speed 2 dB(A) Speed 3 dB(A) Noise power level (5) Speed 1 dB(A) Speed 2 dB(A) Speed 3 dB(A) Fan coil cassette units Range: Cooling capacity: 2 ÷ 7 kW Heating capacity: 4 ÷ 15 kW Available versions: - cooling only - with heating coil 0001 1.84 1.55 320 80 4.38 385 600 22 23 35 33 34 46 0011 2.38 2.05 410 90 5.74 500 900 24 35 47 35 46 58 0012 3.89 3.35 670 90 9.33 810 900 24 35 47 35 46 58 0023 7.04 6.05 1210 100 15.07 1320 1200 31 42 49 42 53 60 21 21 22 23 Weight Weight (basic version) Kg (4)Unit with fans operating at 3th speed (1) Inlet water temperature at 7°C; ambient temperature 27°C DB -19°C WB (2)Water intake temperature at 70°C; ambient temperature 20°C DB (3)According to ISO3741 290 290 580 120 90 55 30 80 250 105 160 10 • Heating coil: Copper tubes /aluminium fins with connections manufactured from die cast brass with Ø 1/2” female BSP threads; each coil is fitted with a manual air vent and drain plug. The coil is tested at a pressure of 15 ATE • Infrared remote control: complete of management electronic cord and receiver fitted on the unit • Intelligent microprocessor control QMP: control with automatic 3-speed and Summer/Winter switching for 2-or 4-pipe fan coil • QB(2): ON/OFF, 3-speed switching • QEI/C(2): ON/OFF, 3-speed switching, fitting for centralised Summer/Winter switch, electronic thermostat and temperature sensor • Minimum thermostat •2-way ON-OFF motor driven valves •3-way ON-OFF motor driven valves 4 connections • Secondary drip tray made of plastic material for condense discharge on collector’s side 450 • Chassis manufactured from galvanized steel. An acoustic and anticondensation insulation is fitted within. Air flow by means of four rectangular opening • Diffuser ABS made (colour RAL9001) • Main heat exchanger: Copper tubes/aluminium fins with threated connections; each coil is fitted with a manual air vent and drain plug. The coil is tested at a pressure of 15 ATE • External rotor fan with ABS centrifugal impellers, single inlet, statically and dynamically balanced • Single phase 23 0V 5 0Hz motor, induction t ype, fit ted with condenser. The motor complies with IP41 protection class and ECM Standards (EC89 /336, EC92 /31, EC93 / 68) and with low voltage standards (Art. 10, EC73/23). Available with 3 speeds • Main drain pan manufactured from preformated plastic material • Filter: syntetic media with a galvanized sheet frame with mesh on both sides 40 O p tions D imensions 150 S tandard F e atures (5)According to ISO 3741 Air supply to an adjacent room Fresh air Auxiliary heating coil 1/2’’ bsp (opt.) 642 Main coil 1/2’’ bsp 290 290 105 160 545 642 95 62 160 05REF656A1A - v 1.0 545 48 49 UTAT Technical D ata 0030B 1st speed UTAT MODEL Fan coil cassette units for underfloor istallations kW kW m³/h W kW m³/h dB(A) Cooling capacity (1) Sensibile cooling capacity (1) Air flow Absorbed power (1) Heating capacity (2) Airflow Noise pressure level (3) Weight Weight (basic version) Range: Cooling capacity: 1 ÷ 2 kW Heating capacity: 1 ÷ 3 kW kg (1) Inlet chilled water temperature: 7°C, water flow; 250 l/h; air ambient temperature: 27°C d.b., 19°C w.b. (2) Inlet hot water temperature: 45°C, water flow; 250 l/h; air ambient temperature: 20°C d.b. 1.74 1.17 221 25 1.64 221 29.9 0030B 2nd speed 0030B 3 th speed 1.96 1.37 280 32 1.98 280 34.0 2.36 1.82 438 50 2.71 438 39.5 10 (3) Values measured at 1 mt. in free field conditions from the unit D imensions S tandard F e atures C onstruc tion O p tions • Structure manufactured in thermoformed plastic, with bearing parts in galvanised steel •2 rows, thermal exchange pack coil with expanded copper tubing and aluminium fins, collectors with threaded air outlet connectors. The coil has been tested at a pressure of 10 bar • Four blade axial fan manufactured in PP 30% GV stabilised to UV rays, statically and dynamically balanced on two levels •230V/1/50Hz winding induction motor with constantly inserted condenser. Class B insulation. Declared to conform with electromagnetic compatibility (according to CE89/336, CE92/31, CE93 / 68 Directives) and low voltage directives (Section 10, Directive CE73/23), IP44 protection level. Three rotation speeds. • CE Directive electrical panel (Directives 73 /23 /CE and EMC 89/336/CE) with unit control card equipped with incorporated relays • Thermoformed plastic condensation collection tray • Cleanable filter in self-extinguishing material with EU2 efficiency, supplied with galvanised plate hooks •230V/1/50Hz Power supply • Self-priming condense discharge pump with heat protection and alarm on NC resistive contact • RS485 serial adaptor • Can-bus serial adaptor • Remote user terminal • Incorporate NTC sensor for ambient temperature adjustment • LCD display with intuitive symbols • Selection of the value to display (temperature, set-point, offset compared with common set-point) • Selective key block (limited functions for offices, hotels...) • Signalling of coded alarms and faults • ON-OFF timer functions • Economy-sleep function • Manual or automatic operation Fan Air filter and chilled/hot water coil Inlet water 1/2” M GAS 522 Condenses drainage pump Power supply 228 564 Condenses drainage pump 05REF686X1A - v 1.0 Outlet water 1/2” M GAS 50 51 Uniflair in the world branches 52 partner production facilities 53 UNIFL AIR: your global partner Aena Spain A&T UK Airport Schiphol Holland AJM Slovenia Alfa Panzió Hungary Amena Spain Analytical Italy Arcont Slovenia Astra Zeneca p.l.c. UK Auna Spain Banca Etica Italy Battersea Reach UK Bayrischer Rundfunk Germany BBC UK Beatrix Potter Gallery UK Bewog Germany Billa AG Italy BMW Germany Bürogebäude Baseler Platz Germany Cheadle Hospital UK Coca Cola Italy Coloplast Danimarca Colt Telecom Europe Comune di Roma Italy CNR Consiglio Nazionale della Ricerca Italy C-Quadrat Austria Dainese Italy Delft University Holland Development Bank of South Africa South Africa Drogerie Markt Slovenia Eastern China Electric Power China Elion Estonia Emt Estonia E.ON Benelux Holland Fairfield Hospital UK Fiducia Germany UK Fisher Clinical Services Fleetwood Hospital UK Fondazione Gaslini Italy Fraunhofer Institut Germany 54 Glasgow Caledonian University UK Greater Manchester Police UK Handmann Germany Heineken Nederland Holland Henkel Slovenia Holiday Inn Europe Honda Racing Team UK Hoteli Piran Slovenia HRF Magyarország Kft. Hungary Imperial College UK INFN Italy Istituto Nazionale Fisica Nucleare InterXion Europe Isoclima S.p.A. Italy Istituto Nazionale delle Assicurazioni I.N.A. Italy Italy Italian Highway Kia Motors Germany Klaverblad Holland LOH - Gruppe Germany Lonza S.p.A. Italy Maidstone Hospital UK Militärhospital Reutovo Russia MTN South Africa NKBM Slovenia MNET South Africa Monzanova National Grid Electricity Transmission plc UK NATO Italy Novacom Kft Hungary O2 Telecom UK OSCE Austria Oesterreichische Nationalbank Austria Oxford University UK Sejm Rzeczypospolitej Polskiej Poland Papyrusmuseum Wien Austria Peace Palace the Haque Holland Philips Magyarország Kft. Hungary Philips Semiconductors UK Politecnico di Milano Italy Princess Maxima Hospital Holland Note Pro Banka Slovenia Radici Novacips Italy Ragn Sells Estonia Red Bull Racing UK Renfrew Community Council UK Rijksmuseum Holland SABC South Africa Sasó Klíma Kft. Hungary Scania Holland Seb Eüp Estonia Siemens Europe Siemens Medical China Sigma-Tau Italy Sitel Corporation Czech Repubblic Sivamont Kft. Hungary South Gas Company Iraq St Mary’s Hospital UK Standard Bank Centurion South Africa Stepping Hill Hospital UK Supermercati Euro-Spin Italy Tallinna Masinatehas Estonia Tatarski Republik Hospital Russia Telecom Argentina Argentina Telecom Italy Italy Telecom Italia Mobile Italy Telefonica Spain Telkom South Africa South Africa T-Mobile Netherlands Holland Tougshan Mobil China United Biscuits UK Università di Venezia Italy Universität Wien Austria Vodacom South Africa Vodafone - Omnitel Italy Volksbank Austria Volkswagen Germany Xfera Moviles Spain Zagreba˘ckaBanka Croatia ZK Getriebe Germany 55 Note 56 05REF602H1A - 11/2007 Headquarters: Uniflair S.p.A. Viale della Tecnica, 2 35026 Conselve (Pd) Italy Tel. +39 049 5388211 Fax +39 049 5388212 info@uniflair.com uniflair.com Uniflair Iberica S.A. Camí De Can Calders No. 8 08173 San Cugat Del Valles Barcelona Spain Tel. +34 935890090 Fax +34 935894513 uniflair@uniflair.es Uniflair GmbH Georg-Wimmer-Ring 18 85604 Zorneding Germany Tel. +49 0810699370 Fax +49 08106993750 zentrale@uniflair.de Uniflair Magyarország KFT Ostoros UT 65/b 1164 Budapest Hungary Tel. + 36 14020661 Fax + 36 14020662 uniflair.hu@uniflair.com Uniflair Limited 33 Star Lane Estate Southend-on-Sea Essex SS3 0PJ United Kingdom Tel. +44 1702219494 Fax +44 1702219898 info@uniflair.co.uk Uniflair (Zhuhai) LTD Uniflair Industry Park Liu Jiao Ting, Jin Ding 519085 - Zhuhai - Guangdong P.R. China Tel. +86 7563386718 Fax +86 7563386728 sales@uniflaircn.com Uniflair India PVT LTD 1001-02 Mercantile House 15 K.G. Marg New Delhi 110 001 India Tel. +91 1143562233 Fax +91 1143562288 sgagneja@uniflair.co.in Uniflair South Africa PTY LTD Unit 8 Meadowdale Industriale Park CNR Koornhof And Essex Str. Meadowdale South Africa Tel. +27 119740053 Fax +27 119740401 erman@uniflairsa.com We are also present in more than 60 countries worldwide through a specialised distribution network (list available at uniflair.com)