Knurr Racks And Liebert Integrated Power, Cooling

Integrated Cabinet Solutions
For Business-Critical Continuity
Knurr Racks And Liebert Integrated Power,
Cooling And Monitoring Products To Protect And Support IT Systems
Knurr And Liebert Technologies Join Together
To Solve Critical Infrastructure Problems
Contents
19” Rack
Knurr Miracel® 19” Server Rack
Knurr Miracel® 19” Open Frame
Knurr Miracel® 19” Distribution Rack
Knurr Miracel® Plinth
Knurr Miracel® Castors
Knurr Miracel® 19” EIA Server Rail
Knurr Miracel® Mounting Adapter
Knurr Miracel® Assembly Kits for Rail
Knurr Miracel® Glass Door
Knurr Miracel® Sheet Steel Door
Knurr Miracel® Side Panel
Liebert XDA Air Flow Enhancer
Knurr Miracel® Partition Wall
Knurr Miracel® Baying Kit
Knurr Miracel® Bottom Cover
Knurr Miracel® Mounting Kits
System Accessories
13
15
15
16
16
17
17
17
18
18
19
19
20
20
22
21
Knurr 19” Shelf
Knurr 19” Heavy-Duty Shelf
Knurr 19” Drawer
Knurr 19” Keyboard Drawer
Knurr Chassis Runner
Knurr 19” Blanking Panel
Knurr TFT Drawer
Power Strips And Managed Power Strips
UPS
Knurr DI-STRIP® TriplePower®
Knurr DI-STRIP® BladePower®
Knurr DI-STRIP® IEC 60320
Knurr IEC 60320 Connection Cable
Knurr DI-STRIP® Classic
Knurr DI-STRIP® Compact
Knurr DI-STRIP® Surge Protector
Liebert MP Advanced Power Strips
Liebert PowerSure PSI UPS
Liebert GXT2U
Liebert GXT2
Liebert 2U Micro POD
Liebert Nfinity UPS
Liebert NX UPS
42
43
44
44
45
45
46
47
Cable Management
24 - 25
26
27
27
28
28
29
Knurr 19” Cable Routing Panel
32
Knurr Cable Routing Strut
33
Knurr Multifunctional Strut
33
Knurr Cable Troughs
34 - 35
Knurr Radial Limit
36
Knurr Excess Cable Storage
37
Knurr 19” Excess Fiber Optic Cable Drawer 37
Knurr Jumpering Bracket
38
Knurr Velco Strip
39
Knurr Cable Cantilever Arm
39
Power Distribution Cabinet
50
52
54
56
58
62
Liebert FDC Distribution Cabinet
64
High Density Cooling
Liebert XD Series
Liebert XDWK (CoolTherm®)
Liebert Adaptive Cooling Solutions
66
68
69
3
Adaptive Technology From The Global Leader In
Enabling Business-Critical Continuity
Emerson Network Power, a business of Emerson, protects
your business-critical systems. We are the global leader in
business critical continuity and bring together industryleading technology brands in racks, power systems,
connectivity, embedded power, outside plant, precision
cooling and monitoring and service.
Liebert and Knurr are part of Emerson Network Power — a division within the global technology leader
Emerson. Liebert & Knurr’s complementary technologies, presented in this selection guide, provide critical
protection from the point your organization connects to the power grid all the way to the processors
crunching data in your data center or a remote computer room.
Through joint research and technology sharing, Emerson Network Power is taking critical availability to new
levels and enabling organizations like yours to achieve their business continuity objectives.
About Liebert
From the first precision cooling system in 1965, to the first UPS load bus synchronization in 1991, to the first
integrated enclosure system in 1994, to the first high-density cooling system in 2002, Liebert technology has
given IT organizations the reliability and flexibility they need to succeed.
There’s a good reason why every company in the Fortune 500 relies on Liebert technology to protect their
mission-critical systems. Liebert has consistently developed the power, cooling and monitoring technologies
that IT organizations rely on to manage growth and integrate new technologies. And they are not alone: 497 of
the InformationWeek 500, 97 of the Computerworld Premier 100, and hundreds of thousands of small and
midsize organizations around the world use Liebert technology to protect business-critical systems.
About Knurr
From its inception in 1931, Knurr has been a leader in the development of metal products. Today, Knurr
designs, produces and integrates standardized and customized rack systems, enclosures, backplanes, thermal
management and power supply systems, applied components and functional furnishing systems. Knurr also
develops and produces power strips, PDUs and power strips internally, which enables the implementation of
standard solutions for customer requirements. You will find more information at: www.knurr.com
4
Network Technology May Be Advancing Faster Than Your
Infrastructure Support Strategy
Your mission-critical networks are carrying an exploding
amount of voice, data and video. Looming on the
horizon is a critical mass of VoIP, high speed access, and
wireless applications. Data centers and network closets
will be asked to deliver reliable 24/7 operation of
critical network communications throughout the
entire enterprise.
Clean, reliable power technology safeguards your
routers, switches, modems and cabling devices from
blackouts and daily power anomalies.
If your critical power & cooling infrastructure cannot
respond to change, your business cannot respond either.
Precision cooling technology tames the heat and
humidity concentrated in small network spaces. You
avoid potential damage to sensitive equipment caused
by corrosion or static.
Cabinets provide the central housing point for
mission-critical IT equipment and the power, cooling &
monitoring products required to ensure the reliability
of the network.
Adaptive monitoring technology helps you manage your
network and avoid costly downtime by collecting real
time status and alarms from your critical power and
cooling infrastructure.
You need an infrastructure that can anticipate and adapt
to change, working across your enterprise to assure the
continuity of your business.
5
Solutions Designed For Your World
Introducing Knurr Ready-to-Deploy Rack & Enclosure Solutions
Knurr, a world leader for standardized rack systems, joins with Emerson Network
Power’s industry-leading Liebert® brand to build comprehensive capabilities in
rack solutions, mission-critical cooling, and systems integration for data center
and telecom sites.
The Knurr broad platform of rack systems will integrate with cooling and power management technologies from Liebert, helping you solve problems in new and existing
installations and giving you more design flexibility.
Knurr & Liebert are taking proven technologies from
room-level applications and integrating them with the rack.
In data centers, Emerson Network Power was first to market with cooling solutions
for extreme density applications with its Liebert XD™ cooling platform. Now it is
taking proven technologies from room-level applications and integrating them
together with the rack.
As the rack becomes a critical product in the data center, network closet and
computer room floor, it serves as a platform for integrating power, cooling, and
information technologies. Market-leading products and technologies from Knurr
support Emerson Network Power’s strategy to make the Liebert Adaptive
Architecture™ the desired standard for IT facilities.
The Liebert XD Units Enhance
The Hot Aisle/Cold Aisle Approach
COLD AISLE
HOT AISLE
COLD AISLE
HOT AISLE
COLD AISLE
COLD AISLE
HOT AISLE
COLD AISLE
HOT AISLE
COLD AISLE
HOT AISLE
Temperature Profile of XDO System
HOT AISLE
Liebert XDV
Liebert XDO
Temperature Profile of XDV System
Temperature
°F °C
95 / 35
86 / 30
The Liebert XDO and Liebert XDV fill the cold
aisle with air at the temperature required for
proper operation of the electronic equipment.
6
77 / 25
68 / 20
60 / 16
You Need An Infrastructure That Can Anticipate And Adapt To Change
The Liebert Adaptive Architecture™ is a
Enhanced Operational Flexibility
combination of power, cooling and monitoring
The components of the Liebert Adaptive Architecture™
technologies that provide mission-critical IT
can be reconfigured to meet the demands of new
support across your entire enterprise. The
technologies, achieve higher tiers of availability
Liebert Adaptive Architecture™ delivers higher
or support increased densities — with minimal
performance with greater flexibility than any
disruption to operations.
other infrastructure design.
Lowest Cost of Ownership
Higher System Availability
Liebert technologies are sized to minimize capital
Proven mission-critical technologies that
equipment expenses and designed for optimum
minimize single points of failure produce the
efficiency. Their ability to adapt to change prevents
highest possible availability of your IT systems.
obsolescence and extends their useful life.
With the Liebert Adaptive Architecture™,
mission-critical technologies aren’t limited to
the data center — they extend wherever you
have mission-critical equipment.
The Evolution Of Critical Infrastructure
Standalone
Singular unit —
reliable and simple
Modular
Cost savings by retaining
initial investment
Added redundancy
Scalable
Flexibility with
internal modularity
A unit with single
direction for growth
Liebert Adaptive
Architecture
Flexibility that can deal
with uncertainty
A platform that works across
the enterprise — small to large
scale — with an optimized building
block approach
Lowest cost method for capital and
operating expenses
7
Knurr Is A Leading Developer And Producer Of Rack And
Enclosure Systems With Additional Components For Electronics
Knurr is at the forefront of enclosure technology, innovation and manufacturing
and has been a dominant industry force throughout the world for more than
75 years.
Our wealth of experience and forward thinking ethos technology leadership
has enabled us to create a product range and expertise in enclosure design,
manufacturing and systems that is second-to-none.
Knurr offers standard enclosure and customised solutions to suit almost every
requirement and environment, whether for 19” electronics, smaller IT rooms
up to large data centers, telecommunications, electrical, or transport management sectors, for example.
With manufacturing plants strategically located throughout Europe, USA,
South America and the Far East, Knurr provides the ideal supply chain. Our
headquarters are in Arnstorf nearby Munich, Germany.
We have a philosophy which is based on local product supply, expertise, service
and support, underpinned by a global presence, which enables us to respond to
customer demands both locally and internationally in equal measure.
8
Having worked closely over many years, with an enviable portfolio of cutomers,
from small companies to global corporations, Knurr has developed a product
range and expertise to resolve almost any enclosure application.
Our extensive standard range enables scaleable, cost-effective solutions and
includes racks and cabinets for indoor and outdoor use, floor and wall mounted, workstation and command center consoles – fixed and mobile, and a
wealth of related accessories.
We are the industry leader in thermally managed cabinets, particularly for data
centers, together with rack monitoring, control, security and alarm systems,
including full remote management system (RMS) via FTP, LAN and WAN, hardwired or Wi-Fi, for both indoor and outdoor applications.
Operating in more than 30 countries, Knurr manufacturing sites combined
with Emerson Network Power divisional companies, provide a model supply
chain that achieves the perfect supply chain management (SCM). With flexible
manufacturing across all our sites, we can readily respond to the local and
international demands of our customers.
OEM version
9
Knurr Miracel® 19“ Rack
Benefits
1
2
4
10
Patented extruded aluminum frame allows
for easy mounting of components.
Plinth can be used in non-raised floor environments to bring cables in the bottom.
Knurr’s mounting adapters allow for the
mounting of many accessories.
2
3
5
Knurrs full line of cable management accessories manages cables effectively.
2
Multifunctional struts allow components to
be mounted anywhere in cabinet.
1
Modular construction
Frame profile offers multiple and
flexible mounting of accessories.
2
Cable management
A complete cable management
system, plus an extensive range of
accessory components.
3
Thermal management
Fully perforated doors, with 83%
open area – far exceeding server
OEM requirements for effective
heat dissipation plus highly effective rear door mounted fan for
spot cooling.
4
Server rails
Server rails guarantee easy mounting of 19” servers of all manufacturers plus Knurr accessories with
special adapter on selected positions.
5
Multifunctional roof
Roof prepared for cable entry or
additional active ventilation.
83% perforated doors exceed OEM requirement and allow the most free airflow in the
industry.
Knurr’s modular roof panel allows for easy
cable access or for mounting of fan trays.
Solutions Oriented With The Spirit Of Innovation
The Knurr Miracel® is a truly multi-talented innovation: the platform technology is the starting point for a versatile range of rack, which has already
been setting recognised standards as
the solution for the most diverse customer requirements.
Easy dismantling and practical
mounting are just some of the features of the Knurr Miracel®, with the
highest possible degree of stability
combined with a low own attribute
weight. The optimum prerequisites
for such a IT solution are provided for
by the extensive accessories range for
that rack, especially for the thermal
and cable management, among other
installations.
Several hundred patents and certificates highlight the inventive spirit at
Knurr even more. Already at the preliminary stage of each project, we
provide support for the customers:
By simulating the mechanical stresses,
the heat distribution and dissipation,
the course is set from the outset with
the definition of the best system.
The 19“ enclosure platforms of Knurr
provide a complete solution concept
which facilitates central and operation-reliable monitoring in the areas
of control an regulation using a highly
differentiated indicator procedure.
This is implemented in order to protect and support IT systems, to prevent costly hardware and/or software
downtime and damage.
Knurr Miracel® 19“ rack protect and
support IT installations and assure the
continuity of your business!
Knurr Miracel® 19“ Rack
Technical Data
Material
- Extruded aluminum
- Corner piece, die-cast
aluminum
- Covers, sheet steel,
zinc passivated
- Doors, sheet steel or with single
safety glass panel, 0.16” (4 mm)
Installation dimensions in
accordance with IEC 297-3
and IEC 917
- Height: 42 HU / 47 HU
(1 HU (or 1U) = 1.75” (44.45 mm))
- Width: 482.6 mm
(19” construction)
Space solution
- 82% of the basic surface can be
used as space for installation and
cable routing
- Front jumpering space, 4.84”
(123 mm) or 3.37” (85.5 mm)
- Door opening angle, 180°
W
W1
Finish / Color
- Basic rack, polished aluminum
- Visible surface of the covers,
powder-coated,
dark-grey RAL 7021
Static load rating
- 1450 lbs with stationary version
- 2000 lbs when bayed
Air flow
Optimized 83% perforation
Tests according to model
- Vibration test in accordance with
MIL-STD 810 E
- IP test in accordance with
IEC 529
- UL test 1244
- Vibration and shock test in accordance with ETS 300 019
- Earthing, VDE 0 100 T 540
Further standards and tests on
request.
Rack suites
To create a rack suite with number
of racks “n”, you require:
- n-1 racks without side panels and
1 rack with side panels
- In a rack suite, per connection
you require one set of suite
connectors
X
[in.]
[mm]
[in.]
[mm]
[in.]
23.62”
600
21.06”
535
19.09” 485
31.50”
800
28.94”
735
26.97” 685
[in.]
[mm]
[in.]
[mm]
[in.]
39.37”
1000
36.61”
930
34.84” 885
D
Configurations
- Stationary, on levelling feet
- Stationary with plinth
- Mobile with plinth and castors
D1
[mm]
Y
[mm]
Conversion
inches to mm: inches x 25.4
mm to inches: mm / 25.4
MIR00332
12
19“ Rack
Knurr miracel® 19” Server Rack
Widths 23.62” (600 mm), front door with perforations
- Basic version without plinth;
order optionally if required
- With special 19” server extrusions for
mounting trade standard servers
- With perforated doors on the front
and rear for optimal airflow, honeycomb
shaped, perforation, 83% airflow
Color
- Visible surface of the covers,
RAL 7021 dark-grey
Protection rating
IP 20
Supply schedule
1 Basic rack
4 19” server EIA rails sheet steel mounting
1 Front door, perforated (perforation 83%)
1 Rear door, perforated (perforation 83%)
Two wing or one wing type
2 Side panels
1 Top cover, closed
1 Complete earthing set
1 Complete locking set
1 cable through vertical rear leftside
1 mounting kit (50 cagenuts, 50 screws,
50 nylon rosetts, 1 allen wrench)
4 levelling feet 0 – 0.98” (0 – 25 mm)
Airflow
Perforation 83%
How supplied
Fully assembled
Jumpering space
Front, 3.37” (85.5 mm)
Load rating
- 1450 lbs,
- 2200 lbs when bayed
Tests
- Earthing in acc. with VDE 0100 T 540
- Vibration test in acc. with MIL-STD 810 E
- IP test in acc. with DIN40 050 / IEC 529
MIR20256
Material / Finish
- Basic rack, extruded aluminum,
polished
- Corner piece, die-cast aluminum
- Multifunctional struts and 19” bracket
extrusions, sheet steel, zinc-passivated
- Visible surface of the covers, powdercoated texture
With between
mounting adapter
(see page 17)
Aperture width of
EIA rails
MIR20131
W
[in.]
[mm]
MIR20131
H
[in.]
D
[mm]
[in.]
HU/U
[mm]
h
[in.]
d
[mm]
[in.]
Weight
[mm]
[lbs.]
Model
Order no.
UP
[kg]
23.62” 600
78.74” 2000
39.37” 1000
42
72.91” 1852
29.13” 740
201
91
1)
01.020.100.0
1 unit
23.62” 600
86.61” 2200
39.37” 1000
47
80.79” 2050
29.13” 740
214
97
1)
01.020.101.0
1 unit
23.62” 600
78.74” 2000
39.37” 1000
42
72.91” 1852
29.13” 740
221
100
2)
01.020.110.0
1 unit
23.62” 600
86.61” 2200
39.37” 1000
47
80.79” 2052
29.13” 740
243
110
2)
01.020.111.0
1 unit
23.62” 600
78.74” 2000
39.37” 1000
42
72.91” 1852
29.13” 740
163
74
3)
01.020.120.0
1 unit
23.62” 600
86.61” 2200
39.37” 1000
47
80.79” 2052
29.13” 740
174
79
3)
01.020.121.0
1 unit
23.62” 600
78.74” 2000
39.37” 1000
42
72.91” 1852
29.13” 740
172
78
4)
01.020.130.0
1 unit
23.62” 600
86.61” 2200
39.37” 1000
47
80.79” 2050
29.13” 740
181
82
4)
01.020.131.0
1 unit
1) single rear door 2) double rear door 3) no side panels, single rear door 4) no side panels, double rear door
To create a rack suite with number of racks “n”, you require: n-1 racks without side panels and 1 rack with side panels
In a rack suite, per connection you require one set of suite connectors
13
19“ Rack
Knurr miracel® Open Frame
Width 23.62” (600 mm) with mounting hole extrusion
Material / Finish
- Basic rack, extruded aluminum,
polished
- Corner piece die-cast aluminum
- Multifunctional frames and 19” angular
extrusions sheet steel, zinc-plated
With fixed 19” EIA rails in the front
and rear
Installation of chassis runners and
19”-shelves possible
For built-in units in accordance with
IEC 297-3
Supply schedule
1 Basic unit
4 19” Sheet steel EIA rails with mounting
holes
2 Multifunctional members for cable clamping and universal assembly options
4 Levelling feet 0 – 0.98” (0-25 mm)
1 mounting kit (50 cagenuts, 50 screws,
50 nylon rosetts, 1 allen wrench)
For the installation of
- 19” Components on the front and rear
- Equipment with maximum width
of 17.72” (450 mm)
- Installation accessories
Jumpering compartment
- Front 2.87” (73 mm)
How supplied
- Assembled
Load rating
- 1450 lbs,
- 2200 lbs when bayed
Please note
Rack suites
In a rack suite, per connection you require a
set of suite connectors (page 18)
Tests
- Earthing according to VDE 0100 part 540
- Vibration test according to
MIL-STD 810 E
MIR00196
W
H
D
HU/U
[in.]
[mm]
[in.]
[mm]
[in.]
[mm]
23.62”
600
78.58”
1996
39.37”
1000
23.62”
600
86.46”
2196
39.37”
1000
A
B
h
H
18.31”
17.72”
2.87”
14
D
A-B
d
23.62”
MIR00300
h
d
Weight
[lbs.]
Order no.
UP
[in.]
[mm]
[in.]
[mm]
[kg]
42
74.80”
1900
25.20”
640
44
20
01.020.160.0
1 unit
47
82.68”
2100
25.20”
640
49
22
01.020.161.0
1 unit
19“ Rack
Knurr miracel® 19” Distribution Rack
Width 31.50” (800 mm), front glass door, mounting hole extrusions
- With fixed 19” installation on the front and
rear for components in acc. with IEC 297-3
- Installation of chassis rails and
19” shelves possible
- Door opening angle, 180°
Jumpering space
Front, 4.84” (123 mm)
Load rating
- 1450 lbs static,
- 2200 lbs when bayed
Protection rating
IP 40
Tests
- Earthing in accordance with
VDE 0100 T 540
- IP test in acc. with DIN 40 050 / IEC 529
MIR00467
Material / Finish
- Basic rack, extruded aluminum,
polished
- Corner piece, die-cast aluminum,
polished
- Covers, zinc-passivated sheet steel,
powder-coated texture
- Doors, sheet steel, powder-coated
texture, glass infill, front door, single
safety glass panel, 0.16” (4 mm)
- Multifunctional struts and 19”
extrusions, sheet steel, zinc-passivated
MIR20223
W
[in.]
[mm]
H
[in.]
D
[mm]
[in.]
HU/U
[mm]
h
[in.]
d
[mm]
[in.]
Weight
[mm]
[lbs.]
[kg]
Color
- Visible surface of the covers, dark-grey
RAL 7021
Supply schedule
1 Basic rack
4 19” sheet steel EIA rails with mounting
holes
2 Multifunctional struts for cable clamping
and universal mounting options
2 Side panels with quick connectors
1 Top cover with integrated cable entry
1 Front door, single, single safety glass
panel, with handle and mounting for
cylinder lock
1 Rear door, sheet steel, with handle and
mounting for cylinder lock
1 cable through vertical rear leftside
1 mounting kit (50 cagenuts, 50 screws,
50 nylon rosetts, 1 allen wrench)
1 Complete earthing set (VDE 0100)
4 Levelling feet 0 – 0.98” (0 – 25 mm)
How supplied
Assembled
Model
Order no.
UP
31.50” 800
78.74” 2000
39.37” 1000
42
74.80” 1900
29.13” 740
273
124
1)
01.020.140.0
1 unit
31.50” 800
86.61” 2200
39.37” 1000
47
82.68” 2100
29.13” 740
293
133
1)
01.020.141.0
1 unit
31.50” 800
78.74” 2000
39.37” 1000
42
74.80” 1900
29.13” 740
247
112
2)
01.020.150.0
1 unit
31.50” 800
86.61” 2000
39.37” 1000
47
74.80” 1900
29.13” 740
265
120
2)
01.020.151.0
1 unit
1) side panels/RAL 7021 2) no side panels/RAL 7021
MIR20223
MIR20300
15
19“ Rack Accessories
Knurr miracel® Plinth
Stationary, height 3.94” (100 mm)
- Stationary
- Cable entry possible from all sides
- Panel front and rear with vent slots and
installation option for filter mat
Load rating
1460 lbs static
MIR00414
Material
Sheet steel
H
[mm]
Supply schedule
4 Plinth corners with levelling
2 Plinth panels with slots
2 Plinth panels closed on the side
Mounting material
How supplied
Flat-packed kit
W
[in.]
Finish
Powder-coated texture, RAL 7021
D
Order no.
UP
39.47” 1000
01.127.650.8
1 unit
39.47” 1000
01.127.652.8
1 unit
[in.]
[mm]
[in.]
23.62” 600
3.94”
100
31.50” 800
3.94”
100
[mm]
Knurr miracel® Plinth
Mobile, 3.94” (100 mm)
- Mobile
- Cable entry possible on the rear
- With levelling feet for stationary model
Load rating
900 lbs static
MIR00077
Supply schedule
1 Plinth frame
2 Fixed castors with snib
2 Swivel castors
Mounting material
How supplied
Flat packed kit
Material
Sheet steel, 0.08” (2 mm)
Finish
Powder-coated texture, RAL 7021
W
[in.]
H
[mm]
D
Order no.
UP
39.47” 1000
01.127.250.8
1 unit
39.47” 1000
01.127.254.8
1 unit
[in.]
[mm]
[in.]
23.62” 600
3.94”
100
31.50” 800
3.94”
100
[mm]
Knurr miracel® Castors
- Can be mounted on the threaded eyelet of the
basic rack
- Castor diameter, 2.95” (75 mm)
- Threaded bolt, M12
- Load capacity per castor: 220 lbs
Supply schedule
2 Castors swivell locking
2 Castors swivell non locking
4 Castors brackets
How supplied
Flat packed kit
MIR20088
W
[in.]
16
H
[mm]
D
[in.]
[mm]
4.31”
109.5
[in.]
Order no.
UP
01.350.615.9
4 unit
[mm]
19“ Rack Accessories
Knurr miracel® 19” EIA Server Rail, Steel
With mounting holes
Material
Sheet steel, 0.08” (2 mm), zinc-passivated
- For mounting trade standard 19” servers
- Please order suitable assembly kit for rack
width 31.50” (800 mm)
- Please order mounting adapter for Knurr
standard components
MIR20041
W
[in.]
H
[mm]
[in.]
D
[mm]
[in.]
Supply schedule
1 x 19” server extrusion
HU/U
Order no.
UP
[mm]
78.74” 2000
42
00.218.010.0
1 unit
86.61” 2200
47
00.218.011.0
1 unit
MIR20082
Knurr miracel® Mounting Adapter for 19” Server Rail
Material
Sheet steel, zinc-passivated
- For mounting Knurr standard components
(storage shelves, drawers, chassis rails, keyboard runners, etc.) in 19” installation space
Supply schedule
4 Adapters
W
MIR20044
[in.]
H
[mm]
[in.]
D
[mm]
[in.]
HU/U
Order no.
UP
01.127.119.9
1 unit
[mm]
1
Knurr miracel® Assembly Kits for Rail
For Racks 31.50” (800 mm) wide
Supply schedule
4 Node brackets (full installation)
Mounting material
W
[in.]
H
[mm]
31.50” 800
[in.]
D
[mm]
[in.]
Modell
Order no.
UP
full inst.
01.131.222.7
1 unit
[mm]
MIR00510
17
19“ Rack Accessories
Knurr miracel® Glass Door
Material
Sheet steel, 1.0 mm,
single safety glass panel, 4.0 mm,
clear glass, double door, 6.0 mm
Supply schedule
1 Glass door, 1 design trim, mounting material
How supplied
Preassembled
Finish / Color
Powder-coated texture, RAL 7021
Door trim, RAL 9011
W
[in.]
H
[mm]
[in.]
HU/U
Model
Order no.
UP
[mm]
800
2000
42
single door
01.130.618.8
1 unit
800
2200
47
single door
01.130.622.8
1 unit
MIR00057
Knurr miracel® Sheet Steel Door
Material
Sheet steel, 1.0 mm
Supply schedule
1 Sheet steel door, 1 design trim,
mounting material
Finish / Color
Powder-coated texture, RAL 7021
W
[in.]
H
[mm]
[in.]
HU/U
How supplied
Preassembled
Model
Order no.
UP
[mm]
31.50” 800
78.74” 2000
42
double door
01.131.842.8
1 unit
31.50” 800
86,61” 2200
47
double door
01.131.847.8
1 unit
MIR00060
Knurr miracel® Sheet Steel Door with Perforation, Double
Material
Sheet steel, 1.0 mm
Supply schedule
1 Door
Mounting material
Finish / Color
Powder-coated texture, RAL 7021
W
[in.]
MIR20277
18
H
[mm]
[in.]
HU/U
Volume flow
A large surface perforation
(83% free surface) enables optimum
airflow through the rack
Model
Order no.
UP
[mm]
23.62” 600
78.74” 2000
double door
01.128.260.8
1 unit
23.62” 600
86,61” 2200
double door
01.128.263.8
1 unit
19“ Rack Accessories
Knurr miracel® Sheet Steel Door with Perforation, Single
Material
Sheet steel, 1.0 mm
Volume flow
A large surface perforation
(83% free surface) enables optimum
airflow through the rack
Finish/Color
Powder-coated texture, RAL 7021
How supplied
Preassembled
Supply schedule
1 Door
Mounting material
W
[in.]
H
[mm]
[in.]
HU/U
Model
Order no.
UP
[mm]
23.62” 600
78.74” 2000
42
door compl RAL 7021
01.128.246.8
1 unit
23.62” 600
86.61” 2200
47
door compl RAL 7021
01.128.250.8
1 unit
MIR20276
Knurr miracel® Side Panel
Material
Sheet steel, 1.0 mm
Supply schedule
1 Side panel
Mounting material
Finish/Color
Powder-coated texture, RAL 7021
D
[in.]
H
[mm]
[in.]
How supplied
Flat packed kit
HU/U
Order no.
UP
[mm]
39.37” 1000
78.74” 2000
42
01.127.739.8
1 unit
39.37” 1000
86.61” 2200
47
01.127.740.8
1 unit
MIR00064
Liebert XDA - Air Flow Enhancer
Increases air flow through densely populated
encolosures
Compatible with most rack enclosures
Redundant fans and dual power feeds
Mount inside or outside of rack
Nominal Capacity Input Voltage
Full load amps
Height
Width
Depth
Weight, unit only
1000 CFM
1.5 A@ 120 V
56”
8”
2.25”
27 lbs
120 V, 1, 60 Hz
230 V, 1, 50/60 Hz
19
19“ Rack Accessories
Knurr partition walls for racks
Material
Sheet steel, 1.0 mm
Supply schedule
1 Side panel
Mounting material
Finish/Color
Powder-coated texture, RAL 7021
D
[in.]
H
[mm]
[in.]
How supplied
Flat packed kit
HU/U
Order no.
UP
[mm]
39.37” 1000
78.74” 2000
42
00.218.020.0
1 unit
39.37” 1000
86.61” 2200
47
00.218.021.0
1 unit
MIR00064
Knurr miracel® Baying Kit
Internal mounting
Supply schedule
8 Mounting brackets
(for connecting 2
racks / cabinets)
Mounting material
- For mechanical, stable connection of rack and
cabinet suites
Material / Finish
- Sheet steel, 0.08” (2 mm), zinc passivated
How supplied
Flat packed kit
MIR00100
W
[in.]
H
[mm]
[in.]
D
[mm]
[in.]
HU/U
Order no.
UP
[mm]
01.130.935.7
1 unit
Knurr miracel® Bottom Cover
For flexible cable entry with rubber sealing, IP 40
Material / Finish
Sheet steel, 0.06” (1.5 mm), zinc-passivated
Sponge rubber,
1.97” x 1.97” (50 mm x 50 mm)
- For covering the rack underside
- With rubber sealing for flexible cable entry on
the front and rear
MIR00355
Protection rating
With installation in the miracel® rack
(depending on the other rack components),
a maximum protection class of IP 40 can
be achieved.
Supply schedule
1 Cable entry
2 Bottom covers
2 Mounting brackets
Mounting material
How supplied
Flat packed kit
W
[in.]
20
H
[mm]
[in.]
D
[mm]
[in.]
HU/U
Order no.
UP
[mm]
23.62” 600
39.37” 1000
01.127.670.0
1 unit
31.50” 800
39.37” 1000
01.127.673.0
1 unit
19“ Rack Accessories
Knurr Front Panel Mounting Kit, Mounting Holes, M5/Plate, 1.5 mm
- For mounting 19” front panels and
19” components
Supply schedule
50 caged nuts, M5 / plate, 1.5 mm
50 countersunk screws, M5 x 16
50 rosettes
How supplied
Flat packed kit
MEC20097
Screw+rosette
Order no.
UP
05.041.000.9
1 set
Knurr Front Panel Mounting Kit, T-Slot, M5, Wide
- For mounting 19” front panels and
19” components
Supply schedule
50 spring nuts, M5 wide
50 countersunk screws, M5 x 12
50 rosettes
How supplied
Flat packed kit
MEC20130
Screw+rosette
Order no.
UP
05.041.340.9
1 set
Knurr Spring Nut
- For clipping into T-slots at any position
M6 for miracel®
Supply schedule
50 Spring nuts
How supplied
Flat packed kit
MEC00060
Model
Order no.
UP
M6
01.350.405.9
1 set
Knurr Countersunk Screw + Rosette
- IEC DIN EN ISO 7047
Supply schedule
50 Countersunk screws
50 Rosettes
How supplied
Flat packed kit
MEC20141
Model
Order no.
UP
M6 x 14
05.041.204.9
1 set
21
System Accessories
22
An optimized range of system accessories allows to prepare a 19"-rack for
fully integration to a networking rack
or a server rack.
The available components support the
assembly of the rack to a system.
Alternatively the components like TFT
drawers of 19" drawers offer additional
functionality themselfs.
Blanking panels in different hights
give the chance to close the 19"
area, when the rack is not fully
loaded.
High end 1U TFT drawers for all 19"
racks. Allow control, monitoring
and administration of computers
inside a rack. Available with 15" or
17" LCD display, optional in combination with KVM (keyboard, video,
mouse) switch.
Flexible chassis runners based on
an aluminum profile support heavy
equipment installed to the rack.
19" shelf range with fix mounted
and pullout versions available. For
high loads also heavy duty versions
in the program range.
19"-drawers, mountable to two 19"
verticals allow well organized storage of tools, documentations, disks
etc.
System Accessories
Knurr 19” Shelf
Fixed
- With perforation to optimise air supply
Material / Finish
Sheet steel 0.04” (1.0 mm), zinc-passivated,
powder-coated texture
Color
RAL 7021, dark-grey
How supplied
Flat packed kit
Load rating
110 lbs static per item
MEC00451
W
D
[in.]
19”
Supply schedule
2 Mounting rails, incl. mounting bracket
1 Shelf board
1 Extension board
(from L = 23.62” (600 mm))
Mounting material
d
[mm]
39.37” 1000
[in.]
W
[mm]
29.13” 740
[in.]
[mm]
16.93” 430
x
L
[in.]
for rack type
Order no.
UP
01.102.005.8
1 unit
[mm]
23.62” 600
miracel®® 19” Rack
Note:
Adapter brackets
required
(page 15)
MEC20018
24
System Accessories
Knurr 19” Shelf
Full pull-out
- With perforation to optimise air supply
Material / Finish
Sheet steel 0.04” (1.0 mm), zinc-passivated,
powder-coated texture
Color
RAL 7021 dark-grey
Supply schedule
1 Pair of telescopic slides
1 Shelf board
1 Extension board
(from L = 23.62” (600 mm))
Mounting material
How supplied
Flat packed kit
MEC00462
Load rating
110 lbs static per item
W
D
[in.]
19”
d
[mm]
39.37” 1000
[in.]
W
[mm]
29.13” 740
[in.]
x
[mm]
L
[in.]
16.93” 430
for rack type
Order no.
UP
01.102.162.8
1 unit
[mm]
23.62” 600
miracel®® 19” Rack
Note:
Adapter brackets
required
(page 15)
MEC20020
Knurr 19” Tool Less Shelf
Fixed
- With perforation to optimise air supply
Material / Finish
Sheet steel, powder-coated texture
Supply schedule
1 complete Shelf
How supplied
Flat Box, fully assembled
Color
black
Load rating
150 lbs static per item
MEC20161
W
D
[in.]
19”
d
[mm]
23.75” 603
[in.]
W
[mm]
[in.]
[mm]
17.25” 438
x
L
[in.]
for rack type
Order no.
UP
00.218.500.0
1 unit
[mm]
23.75” 603
all EIA racks with square
25
System Accessories
Knurr 19” Heavy-Duty Shelf
Fixed
- Surface area with perforation
Material / Finish
Sheet steel 0.06” (1.5 mm), zinc-passivated,
powder-coated texture
Color
RAL 7021 dark-grey
Supply schedule
1 Shelf fixed, screwable
Mounting hardware
How supplied
Flat packed kit
MEC00120
W
D
[in.]
19”
Load rating
220 lbs static for CW installation
300 lbs static for 19” installation
d
[mm]
39.37” 1000
[in.]
W
[mm]
29.13” 740
[in.]
x
[mm]
L
[in.]
18.39” 467
for rack type
Order no.
UP
01.131.474.8
1 unit
[mm]
22.05” 560
miracel®® 19” Rack
Note:
Adapter brackets
required
(page 15)
MEC20117
Knurr 19” Heavy-Duty Shelf
Full pull-out
- With perforation to optimise air supply
- Locking in pushed-in and fully pulled-out
position
- Simple mounting with patented quick
mounting system
Material / Finish
Sheet steel 0.06” (1.5 mm), powder-coated
texture
MEC20022
W
D
[in.]
19”
d
[mm]
39.37” 1000
[in.]
W
[mm]
29.13” 740
[in.]
[mm]
16.22” 412
x
L
[in.]
for rack type
Color
RAL 7021 dark-grey
Load rating
250 lbs static
Supply schedule
1 Pair of telescopic slides
1 Shelf board
Mounting material
Order no.
UP
01.102.032.8
1 unit
[mm]
29.98” 660
miracel®® 19” Rack
Note:
Adapter brackets
required
(page 15)
MEC20113
26
System Accessories
Knurr 19” Drawer
Installation on the front
Load rating
30 lbs static
- For installation on the front 19”
extrusions
- For storing service documents
- Simple and quick mounting
Supply schedule
1 19” Drawer with lock, including key
1 Pair of telescopic slides
Mounting material
Material / Finish
Drawer, sheet steel 0.04” (1.0 mm),
powder-coated texture
Telescopic slides, sendzimir zinc-coated
SCH00058
How supplied
Preassembled
Color
RAL 7021, dark-grey
W
19”
H
D
HU
[in.]
[mm]
[in.]
[mm]
3.47”
88.1
23.62-39.37”
600-1000
2
For rack type
Order no.
UP
miracel®® 19” Rack
01.113.927.8
1 unit
SCH00054
Knurr 19” Keyboard Drawer 1 HU/U
For 19” keyboard
Supply schedule
1 19” Keyboard drawer, 1 U
1 Pair of telescopic slides
Velcro strip for fixing keyboard
Mounting material
- With hand rest
- With cable strain relief
Material
Main unit, sheet steel, 0.04” (1.0 mm),
Front panel, sheet steel, 0.04” (1.0 mm)
How supplied
Pre-assembled
Finish / Color
Powder-coated, textured, RAL 7021
dark-grey
SCH00059
W
19”
H
D
HU
[in.]
[mm]
[in.]
[mm]
1.72”
43.6
35.43” 900
d
[in.]
1
For rack type
Order no.
UP
[mm]
29.13” 740
miracel®® 19” Server 02.011.101.8
1 unit
Note:
Adapter brackets
required
(page 15)
SCH00055
27
System Accessories
Knurr Chassis Runner
Screw fitting
- For installation in 19” cabinet and enclosure
- For heavy installations
TEM00066
Supply schedule
1 Chassis runner
Material
Extruded aluminum 0.08” (2.0 mm)
Load rating
110 lbs Static per unit
Finish
Polished
Note
Please also order mounting material
D
[in.]
d
[mm]
[in.]
L
[mm]
[in.]
For rack type
Order no.
UP
[mm]
39.37” 1000
25.20” 640
23.07” 586
miracel®® 19” Server
01.110.727.0
1 unit
39.37” 1000
29.13” 740
27.01” 686
miracel®® 19” Server
01.110.728.0
1 unit
MIR00220
Note:
L
Adapter brackets
required
(page 15)
TEM00069
Knurr 19” Blanking Panel
- For covering free front areas
Supply schedule
1 19” blanking panel
Material
Sheet steel, 0.06” (1.5 mm)
How supplied
In units
Finish
Powder-coated texture, RAL 7021,
dark-grey
CUD00005
H
HU
Model
Order no.
UP
1
powder-coated
01.117.026.8
1 unit
2
powder-coated
01.117.028.8
1 unit
132.5
3
powder-coated
01.117.029.8
1 unit
10.47” 265.9
6
powder-coated
01.117.030.8
1 unit
H
W
Note
Please also order front panel mounting kit,
cage nuts and screws.
CUD00004
28
[in.]
[mm]
[in.]
[mm]
18.31”
19”
482.6
1.72”
43.6
19”
19”
482.6
3.47”
88.1
19”
482.6
5.22”
19”
482.6
System Accessories
Knurr TFT Drawer, 1 HU, TD17
For 19” installation
VHP20333
- Space-saving with only 1 HU installation
height
- Low installation depth
- Integrated country-specific laptop keyboard
with touchpad
- TFT in the pushed-in status protected from
below
- Mechanical switch turns off power to display in
folded position
- Interlocking full extension rails
- With 2 snap lock catches on the front
(transport and pushed-in status safety)
- Hand support of sponge rubber for relaxed
writing
- Touchpad with left and right mouse button
- Integrated wide range input power supply
(100 - 240 Vac ) with IEC 320 socket and
protected contact mains cable
17” Display Technical Data (TD17)
- 17” TFT LCD display
- Resolution, 1280x 1024 (SXGA)
- Typical brightness, 250cd/m22
- Contrast ratio 500:1 (typical)
- 16.7 million colours
- On-screen menu
- Changes that stay abreast of technical
progress
Color
RAL 7021 , dark-grey
Supply schedule
1 VGA cable
1 Mouse cable PS/2
1 Keyboard cable PS/2
1 TFT Drawer
1 Mains cable
Telescopic slides with mounting set
D 31.50 - 39.37” (800 mm - 1000 mm) /
d 21.65 - 33.46” (550 mm - 850 mm)
1 2-point hinged cable router
Operating instructions
Knurr TFT Drawer, 1 HU, TD17
W
VHP20047
D
[in.]
19”
HU
Display
Model
Order no.
UP
1
17” LCD
USA
06.111.002.8000001
1 unit
[mm]
16.93” 430
Note:
Adapter brackets
required
(page 15)
VHP20332
29
Cable Management
Bending loads
The bending radii may never be
less than the values provided by
the cable manufacturer in their
respective data sheets. At points
that bend too much, the electrical
properties of the cable change and
reduce the transmission bandwidths and ranges. If manufacturer
specifications are not available,
then the following rule of thumb
applies: With loose cabling, at least
15 times the external cable diameter and with fixed cabling, at least
10 times the external cable diameter.
Kink stress
The most extreme bending loads
can cause the cable to break.
Tensile stress
This is only determined by the copper cross-section of the conductor,
as all other materials are too soft.
The cable may not be stressed
more than 11 lbs/sf (Cu cross-section) as otherwise the conductors
are stretched and the cross-section
is reduced. If higher “pulling” forces are required, then cables with
additional strain relief elements
must be used.
Compressive stress
Compressive stress is caused by
loads bearing down from above,
fixed clamping or sharp cable kinking and must always be avoided, as
otherwise the “loose” cable structure changes and the electrical
transmission properties are
impaired.
30
Torque strains (Twisting)
Cables must not be twisted, or this
can cause a charge inelectrical
properties.
Different components for fiberoptic and copper cables, especially
the fastening options using Velcro
strips and cable bundling using different colored strips, guarantee
transparent cable management,
which is the optimum starting situation for an intelligent expansion
of the network and for the highest
standard of service convenience.
With all cable management components, special attention has
been paid in ensuring that fixing
can be made using Velcro strip
cable ties. Velcro cable ties not
only guarantee a stress-free fixing
of the cable, but rather can also be
released at any time and re-used
again and again. Velcro cable ties
are also extremely helpful for the
installation engineer in providing
pinch-free cable bundling, and also
because they are so quick to apply.
The storage of excess cable
lengths should be separated from
the patch fields, however in a position that is always easily accessible.
Copper cable excess can be stored
separate from fiberoptic excess
lengths within the Knurr rack
systems.
The copper cables are stored
hanging on a side and the more
sensitive fiberoptic cables are
stored flat in a front-opening
excess cable drawer.
A closer look at the individual
products reveals that some possess an inherent “multitalent”.
The multifunctional cable routing
strut, for example, not only provides the option of routing cables
horizontally and vertically using
Velcro ties or cable ties, but
rather also allows numerous components to be mounted using
caged nuts and screws. These
caged nuts can also be shifted with
room for play in a slot, so that
every mounting dimension can be
accommodated.
The radial limiter maintains proper
minimum bend radius to ensure
the cables transmission properties
are maintained.
Cable Management
Knurr 19” Cable Routing Panel
2 HU/U
- For safe and orderly routing of fiber optic
and copper cables
Material / Finish
Front panel, sheet steel, 0.06” (1.5 mm),
powder-coated, RAL 7021
MEC20014
W
19”
H
[in.]
[mm]
1.75”
44.5
Dimensions
Cable routers: 3.74 x 1.26” (95 x 32 mm),
steel
Supply schedule
1 19” Front panel
5 Cable routers
HU/U
Order no.
UP
1
01.117.144.8
1 unit
Knurr Cable Routing Panel, 1 HU
- For orderly cable management in the rack
internal space
- With edge protector
Material / Finish
Sheet steel, 0.06” (1.5 mm)
Powder-coated texture, RAL 7021
Supply schedule
1 19” Cable routing panel
How supplied
In units
Note
Please also order suitable front panel
mounting material.
CUD00021
W
[mm]
1.75”
44.5
0.59 / 1.77”
19”
H
[in.]
15.55”
18.31”
19”
CUD00022
32
CUD00023
HU/U
Order no.
UP
1
01.117.020.8
1 unit
Cable Management
Knurr Cable Routing Strut
- For mounting on the miracel® cabinet and on
the 19” EIA rail
- For cable clamping using Velcro strips,
cable ties
- For orderly cable management in the rack
- For universal mounting option using caged
nuts (all dimensions can be accommodated,
as caged nuts are flexible)
MEC20091
Material / Finish
Sheet steel, 0.06” (1.5 mm), zinc-passivated
Supply schedule
1 Cable routing strut
Mounting material
How supplied
In units
Note
If required, please also order Velcro strip.
W
D
[in.]
L
[mm]
39.37” 1000
19”
[in.]
For rack type
Order no.
UP
[mm]
33.66” 855
position 1
miracel®®
05.040.005.0
1 unit
18.43” 468
position 3
miracel®®
05.040.011.0
1 unit
MEC20078
Knurr Multifunctional Strut
- For routing cables with cable ties and for universal mounting option
- Holes for mounting caged nuts
- Distance between two multifunctional struts
can be variably selected using T-slot
- Installation on the extrusions of the rack frame
or on the 19” extrusions, diagonal and lateral
- Type A – For universal application
- Type B – Especially for fixing cable ties,
no threading required
MIR00089
Material
Sheet steel, 0.06” (1.5 mm)
Finish
Zinc-passivated
Installation positions
1 on the basic rack on the depth
2 on the basic rack on the width
3 on the 19” extrusions on the width
4 on the 19” extrusions on the depth
Supply schedule
1 Multifunctional strut
D
2
d
[in.]
[mm]
39.37”
1000
35.43/39.37”900/1000
[in.]
For rack type
Order no.
UP
position 1
miracel®®
01.127.690.0
1 unit
position 4
miracel®®
01.130.782.0
1 unit
[mm]
29.13” 740
D
3
1
4
MIR00090
33
Cable Management
Knurr Cable Trough
Supply schedule
1 Cable trough
Mounting material
- For orderly cable management in the
miracel® rack
- Mounting cables using Velcro strips or
cable ties
- Combination possible as L, U or T unit
How supplied
Flat packed kit
Material / Finish
Sheet steel, 0.06” (1.5 mm), zinc-passivated,
powder-coated, RAL 7021
Note
If required, please also order Velcro strip.
Dimensions
L 5.91 x W 1.10” (L 150 x W 28 mm)
HU/U
Model
Order no.
UP
42
miracel®®
05.040.021.8
1 set
47
miracel®®
05.040.022.8
1 set
MEC20088
Knurr 19” Cable Trough
- For orderly cable management in front of the
19” front
- Mounting possible on the front panels
- Cable fixing possible using Velcro strips
Material / Finish
Sheet steel, 0.06” (1.5 mm)
Powder-coated texture, RAL 7021
Supply schedule
1 Cable trough
How supplied
In units
Note
Please also order suitable front panel
mounting material and Velcro strip.
MEC20049
W
19”
MEC20063
34
D
HU/U
[in.]
[mm]
3.94”
100
1
Order no.
UP
05.040.055.8
1 unit
Cable Management
Knurr Cable Trough Between the Racks
- For orderly cable management between
linked racks
- Mounting possible using Velcro strips
Material / Finish
Sheet steel, 0.06” (1.5 mm)
Powder-coated texture, RAL 7021
Supply schedule
1 Cable trough
Mounting material
How supplied
Flat packed kit
Note
Please also order Velcro strip
MEC20042
W
[in.]
D
[mm]
10.43” 265
[in.]
[mm]
2.36”
60
Order no.
UP
05.040.058.8
1 unit
MEC20119
35
Cable Management
Knurr Radial Limit
- Various installation options available:
- on the basic rack for cable clamping
- on the 19” EIA rail for cable rerouting and
cable management
Material / Finish
Sheet steel, 0.06” (1.5 mm), zinc-passivated
Supply schedule
1 Radial limit
Mounting material
How supplied
Flat packed kit
W
MEC20090
[in.]
D
[mm]
11.42” 290
[in.]
[mm]
3.43”
87
Order no.
UP
05.040.090.0
1 set
MEC20071
Knurr Radial Limit, 1 HU
- For vertical cable rerouting from the patch
area
- The cables can be fixed with Velcro strips
- Lateral use in conjunction with the cable duct
is possible
Material / Finish
Sheet steel, 0.06” (1.5 mm),
powder-coated texture, RAL 7035
Supply schedule
1 Radial limit
1 Mounting panel
Mounting material
How supplied
Flat packed kit
MEC20132
W
36
D
[in.]
[mm]
[in.]
[mm]
3.35”
85
1.26”
32
HU/U
Order no.
UP
1
05.040.091.1
1 set
Cable Management
Knurr Cu (Copper) Excess Cable Storage
- For storing excess copper cables
(or fiber optic cables)
- For orderly cable management in the
miracel® rack
- Can be expanded
Supply schedule
1 Excess cable holder
Mounting material
How supplied
Flat packed kit
Material / Finish
Sheet steel, 0.06” (1.5 mm), zinc-passivated
MEC20052
W
H
D
HU/U
Model
Order no.
UP
for rack type - miracel®®
05.040.044.0
1 set
MEC20079
Knurr 19” Excess Fiber Optic Cable Drawer, 1HU
- For excess fiber optic cable storage
- Pull-out
- Cable fixing possible using Velcro strips
Material / Finish
Sheet steel, 0.06” (1.5 mm)
Powder-coated texture, RAL 7021
Supply schedule
1 Main unit
1 Drawer
How supplied
Flat packed kit
Note
Please also order suitable front panel
mounting material and Velcro strip.
MEC20047
W
19”
H
D
[in.]
[mm]
[in.]
1.72”
43.6
13.78” 350
Order no.
UP
05.040.047.8
1 set
[mm]
MEC20099
37
Cable Management
Knurr Jumpering Bracket, Universal
Supply schedule
1 Jumpering bracket
- Can be used for extrusion spacing
(from front), 123 mm and 73 mm
- For tidy and orderly cable management
- Open version, no tedious cable looping
- Mounting on the external side of the 19”
extrusion
- Installation position freely selectable
How supplied
In units
Note
Please also order the appropriate
mounting material.
Material / Finish
Round steel,
d = 0.24” (6 mm), zinc-passivated
MEC20038
W
[in.]
[mm]
from 31.50”
from 800
Model
Order no.
UP
for rack type miracel®®
05.040.025.0
1 unit
MEC20072
MEC20106
Knurr Jumpering Bracket, Flexible
1
- For flexible and orderly cable management
- Installation place and position freely selectable
- Open version, no tedious cable looping
2
3
Material / Finish
Round steel,
d = 0.20” (5 mm), zinc-passivated
A
MEC20035
Supply schedule
1 Jumpering bracket
Mounting material
a
How supplied
Flat packed kit
W
w
[in.]
[mm]
[in.]
[mm]
[in.]
[mm]
[in.]
[mm]
3.23”
82
2.83”
72
1.69”
43
1.30”
33
MEC20065
MEC20108
38
Model
Order no.
UP
fig. 1
05.040.031.0
1 unit
Cable Management
Knurr Velcro Strip (in meters)
Material / Color
Black: One Wrap Fastener
F.R.T., UL 94-V2
Blue: One Wrap Fastener
- For stress-free mounting and bundling of
copper and fiber optic cables
- Velcro strip can be cut to any length
required
Supply schedule
1 Meter or 25 meter Velcro strip
How supplied
Meter strips
MEC20048
W
L
[in.]
[mm]
[in.]
0.63”
16
39.37” 1000
Model
Order no.
UP
black
05.040.060.9
[mm]
1 unit
MEC20147
Knurr Cable Cantilever Arm
MEC20094
- Swing-out from the rear, therefore free access
to the rear side
- For simple mounting in rack/on the shelf;
quick connecting to and disconnecting from
shelf or rack with a spring clip
- Guarantees defined and kink-free
cable management
- Minimum space requirement behind the
pushed in shelves, 40 mm
W
H
D
HU/U d
WxL
Material / Finish
Sheet steel, 0.06” (1.5 mm), zinc-passivated
Supply schedule
1 Cable cantilever girder
Mounting material
How supplied
Flat packed kit
For rack type
Order no.
UP
05.040.095.0
1 unit
9.25”
MEC20101
MEC00125
MEC00126
MEC00127
39
Power Strips And Managed Power Strips
Benefits
1
1 HE
= 44,45 mm
m
465 m
m
483 m
5
40
Robust
Plug field protected with raised
casing edges
2
Stability
High stability and torsional
strength provided through closed
sheet steel casing
2
Electrical Safety
Full power for all connected consumers due to full-length brass
busbar
Shock hazard-proof and low contact resistance with double spring
contacts
3
19” Installation
Optimal use of space with
19” installation:
- With low height, 1 HU
(44.45 mm)
- With 45° positioning of the sockets
4
International compatibility
Numerous standard products
in accordance with international
norms and standards. Special
models on request.
5
USA NEMA standard
Wide product range of NRTL
approved USA plug strips.
6
Aesthetics
Appealing design with extruded
housing and design side panels in
visible area.
7
Cost-conscious
Simple and quick mounting on the
rack extrusion.
2
19’’
3
1
4
6
Universal
1 and 3-phase systems.
8
Modularity
Socket strip modules can be easily
combined using plug-in connections.
8
Plug-in
Proven GST18 plug-in system for
connecting socket strip modules.
Certifications
Worldwide approvals and certifications as proof of quality.
7
8
Power Strips And Managed Power Strips
Knurr DI-STRIP® TriplePower®
Benefits
1
Cost-conscious
Simple and quick mounting on the
rack extrusion.
Costs reduction with regard to
mounting and wiring.
2
Feed
- 3x16A as standard
- Ideal for implementing
redundancies (e.g. 96 A)
1
3
3
At a glance
Color coding of phase
assignment (L1, L2, L3).
4
Installation
Optimum distribution over the
entire rack height
(23 HU and 41 HU).
2
4
Knurr DI-STRIP® TriplePower®, IEC 60320
With cable
- With 3-way combinations of
IEC 60320 sockets (AWG 14)
- Cable: H05VV-F 5G 2.5 mm2
- Cable: 100” (2.5 m)
- Simple mounting on the rack extrusion
- 3x16A feed as standard
- Ideal for implementing redundancies
(e.g. 96 A with redundant feed)
- Color coding of the phase assignment
- Optimum distribution over the entire rack
height (23 HU and 41 HU)
- with IEC 60309 plug
DOS20126
Approvals/Certificates
- CE label in accordance with low voltage
guideline 73/23/EWG,
EMC guideline 89/336/EWG
- CSA NRTL C/US (UL/CSA 60950)
- CB Scheme
- Innova GS
Color
Casing: RAL 7035 light-grey
Plastic parts: RAL 7021 dark-grey
Rating
100–240/173–415 Vac
Input: max. 3x16 A
Output: per outlet 10 A (15 A)
Material / Finish
Enclosure: closed sheet steel extrusion,
zinc-passivated, powder-coated texture
Plastic parts:
Vampamid 6 0024 V0 (UL 94), recyclable
Approval symbols for IEC 320 3-way
combinations
VDE, UR, CSA
Dimensions
Socket spacing: 0.94” (24 mm)
Height: 1.79” (45.5 mm)
Casing width: 1.75” (44.4 mm (= 1 HU))
L
L = Length, S = Switch, n = Number of sockets,
F1 = Standard side piece, F2 = Design side piece,
19” = Suitable for 19” installation, Safe = Child-safe
HU = Standard height unit, UP = Unit of packaging
42
S
n
F1
Order no.
UP
24 ●
03.600.024.1
1 unit
48 ●
03.600.048.1
1 unit
●
03.600.824.1
1 unit
●
03.600.848.1
1 unit
[in.]
[mm]
40.67”
1033
72.17”
1833
40.67”
1033
24 ●
72.17”
1833
48 ●
F2
19“
Safe
Supply schedule
1 Socket strip
2 Mounting brackets
plug
Model
Power Strips And Managed Power Strips
Knurr DI-STRIP® Blade Power®
A new generation of the power distribution units of the Knurr DI-STRIP®
range now ensures even more power:
Knurr BladePower® for fail-safe power
supply distribution in network racks.
Increasingly greater packing densities
and therefore constantly increasing
energy requirements in server racks
caused by blade servers or 1 U rack
servers will now be handled electro
technically.
Up to 35 kW dissipated heat can be
removed from modern Knurr CoolTherm® server racks. But how is the necessary power supplied into the rack,
which can cause such power losses?
Knurr DI-STRIP® BladePower®
Benefits
Cost-Effective
Simple and quick installation on
the server rack’s extrusion. Cost
reduction in installation and
wiring.
Installation
Optimum distribution of blade
centre supply with simple installation of power distribution unit
(PDU).
Supply
- Single-phase 32 A and
three-phase 32 A.
- ≤22 kVA
- Ideal for implementing
redundancy (e.g. 192 A).
Availability
Prevention of “Single Point of
Failure“ with individual fusing.
Certification
Crystal Clear Assignment
Unmistakeable phase assignment
through colour coding (L1, L2, L3).
The Knurr BladePower® (3x32 A) optimally distributes the required power
over the entire rack, with connection of
up to 15 consumers possible in the
highest configuration level. 192 A can
be supplied to the rack with redundant
feed via the Knurr BladePower®.
Knurr DI-STRIP®BladePower®
Technical Data
- IEC 320 sockets (10 A and 16 A).
- Individually fused via thermal circuit breaker
that can be reset in acc. with IEC600934.
- Cable: H05VV-F 5 G 4 mm2 (AWG 12).
- Cable: 157.48” (4 m).
- With IEC60309 plug.
Approvals
- CE label in accordance with low
potential guideline 73/23/EWG,
EMC guideline 89/336/EWG
- CSA NRTL C/US (UL/CSA 60950)
- Innova GS
DOS20153
Material / Finish
Casing: Sheet steel, zinc passivated,
powder-coated
Load Rating
240/415 V, 1x 32 A, 3x 32 A,
Euro module 10/16 A
1~ 100 - 240 Vac, 50 - 60 Hz, max. 32 A
3~ 100 - 240 / 173 - 415 Vac, 50 - 60 Hz,
max. 3 x 32 A
Euro module 10/16 A; 15/20A (NA)
Dimensions
Height: Approx. 2.36” (60 mm).
Casing width: 3.31” (84 mm)
Color
Casing: RAL 9005, black
Supply Schedule
1 socket strip (PDU)
2 mounting brackets
1 19“ mounting bracket
1 operating instructions.
DOS20155
L
n
F1
14.76” 375
5
●
29.13” 740
15 ●
14.76” 375
5
29.13” 740
15 ●
[in.]
L = Length, S = Switch, n = Number of sockets,
F1 = Standard side piece, F2 = Design side piece,
19” = Suitable for 19” installation, Safe = Child-safe
HU = Standard height unit, UP = Unit of packaging
S
F2
19“
plug
Model
Order no.
UP
●
●
BladePower® PDU 1x 32 A
03.630.005.1
1 Unit
●
BladePower® PDU 3x 32 A
03.630.015.1
1 Unit
BladePower® PDU 1x 32 A
03.630.805.1
1 Unit
BladePower® PDU 3x 32 A
03.630.815.1
1 Unit
[mm]
●
●
43
Power Strips And Managed Power Strips
Knurr DI-STRIP®, IEC 60320
L
[in.]
S
483
DOS00458
n
F1
9
●
F2
19“
safe
Model
Order no.
UP
03.622.009.1
1 Unit
[mm]
●
Approvals/Certificates
- CE label in accordance with low voltage
guideline 73/23/EWG,
EMC guideline 89/336/EWG
- CSA NRTL C/US (UL/CSA 60950)
- CB Scheme
- Innova GS
- Inlet with fine-wire fuse 10 A
- Optionally with back-lit switch,
2-pole switching
- 19“ Installation option
- With 3-way combinations of
IEC 60320 sockets
Material / Finish
Enclosure: closed sheet steel extrusion, zinc
passivated, powder-coated, textured
Plastic components:
Vampamid 6 0024 V0 (UL 94), recyclable
Dimensions
Socket spacing: 0.94” (24 mm)
Height: 1.79” (45.5 mm)
Enclosure width: 1.75” (44.4 mm (= 1 HU))
Color
Enclosure: RAL 7035 light-grey
Plastic components: RAL 7021 dark-grey
Rating
100–240 Vac
Input: max. 10 A
Output: per outlet 10 A
Compliance symbols for IEC 320 3-way
combination
VDE, UR, CSA
Supply schedule
1 Socket strip
2 Mounting brackets
2 19’’ Mounting brackets
Knurr IEC 60320 Connection Cable
Mains voltage
125 Vac
- Mains plug: IEC 320 - socket IEC 320
- Cable: SJT AWG18
Nominal current
10 A
L
DOS00519
L = Length, S = Switch, n = Number of sockets,
F1 = Standard side piece, F2 = Design side piece,
19” = Suitable for 19” installation, Safe = Child-safe
HU = Standard height unit, UP = Unit of packaging
44
S
[in.]
[mm]
39”
990
n
F1
F2
19“
plug
Model
Order no.
UP
04.000.052.9
1 Unit
Power Strips And Managed Power Strips
Knurr DI-STRIP® Classic
Standard USA NEMA5-15R
- With lit switch
- With overload protection 15A
- Cable: SJT 14 AWG x 3C
- Molded plug NEMA5-15 P
DOS00685
Material / Finish
Enclosure: closed sheet steel extrusion,
zinc-passivated, powder-coated texture
Plastic parts:
Vampamid 6 0024 V0 (UL 94), recyclable
0.71”
0.20”
1.75”
0.20”
DOS00670
With switch
Dimensions
Socket spacing: 3.94” (100 mm)
Height: 1.79” (45.5 mm)
Casing width: 1.75” (44.4 mm (= 1 HU))
Cable: 196.85” (5 m)
Approvals/Certificates
- CE label in accordance with low voltage
guideline 73/23/EWG,
EMC guideline 89/336/EWG
- CSA NRTL C/US (UL/CSA 60950)
- CB Scheme
- Innova GS
Color
Enclosure: RAL 7035 light-grey
Plastic parts: RAL 7021, dark-grey
Socket parts and cable: RAL 9011,
graphite black
Rating
125 Vac/15 A
Supply schedule
1 Socket strip
2 Mounting brackets
L
[in.]
S
n
F1
●
12 ●
F2
19“
safe
Model
Order no.
UP
with switch
03.532.062.1
1 Unit
[mm]
54.45” 1383
Knurr DI-STRIP® Compact
Standard USA NEMA5-15R
- With lit switch
- With overload protection 15A
- 19” Installation option (with length 483 mm)
- Cable: SJT 14 AWG x 3C
- Molded plug NEMA5-15 P
DOS00686
Material / Finish
Enclosure: closed sheet steel extrusion,
zinc-passivated, powder-coated texture
Plastic parts:
Vampamid 6 0024 V0 (UL 94), recyclable
0.71”
0.20”
1.75”
0.20”
DOS20016
With switch
Dimensions
Socket spacing: 1.26” (32 mm)
Height: 1.79” (45.5 mm)
Casing width: 1.75” (44.4 mm (= 1 HU))
Cable: 98.43” (2.5 m)
Approvals/Certificates
- CE label in accordance with low voltage
guideline 73/23/EWG,
EMC guideline 89/336/EWG
- CSA NRTL C/US (UL/CSA 60950)
- CB Scheme
- Innova GS
Color
Enclosure: RAL 7035 light-grey
Plastic parts: RAL 7021, dark-grey
Socket parts and cable: RAL 9011,
graphite black
Rating
125 Vac/15 A
Supply schedule
1 Socket strip
2 Mounting brackets
2 19” Mounting brackets
L
[in.]
S
n
F1
●
9
●
F2
19“
safe
Model
Order no.
UP
with switch
03.532.009.1
1 Unit
[mm]
19.02” 483
●
L = Length, S = Switch, n = Number of sockets,
F1 = Standard side piece, F2 = Design side piece,
19” = Suitable for 19” installation, Safe = Child-safe
HU = Standard height unit, UP = Unit of packaging
45
Power Strips And Managed Power Strips
Knurr DI-STRIP® Surge Protector
Standard USA NEMA5-15R
Approvals/Certificates
- CE label in accordance with low voltage
guideline 73/23/EWG,
EMC guideline 89/336/EWG
- CSA NRTL C/US (UL/CSA 60950)
- CB Scheme
- Innova GS
- With lit switch
- With overload protection 15A
- With overvoltage protection
- 19” Installation option
- Cable: SJT 14 AWG x 3C
- Molded plug NEMA5-15 P
DOS00687
DOS20017
With overvoltage protection
Material / Finish
Enclosure: closed sheet steel extrusion,
zinc-passivated, powder-coated texture
Plastic parts:
Vampamid 6 0024 V0 (UL 94), recyclable
Dimensions
Socket spacing: 1.26” (32 mm)
Height: 1.79” (45.5 mm)
Casing width: 1.75” (44.4 mm (= 1 HU))
Cable: 98.43” (2.5 m)
Color
Enclosure: RAL 7035 light-grey
Plastic parts: RAL 7021, dark-grey
Socket parts and cable: RAL 9011,
graphite black
Technical data
Mains voltage 125 Vac
Nominal current 15A
Surge current resistance (8/20 µs wave):
max. 8 kA
Protection level: < 800 V
Supply schedule
1 Socket strip
2 Mounting brackets
2 19” Mounting brackets
L
[in.]
19.02” 483
L = Length, S = Switch, n = Number of sockets,
F1 = Standard side piece, F2 = Design side piece,
19” = Suitable for 19” installation, Safe = Child-safe
HU = Standard height unit, UP = Unit of packaging
46
S
n
F1
●
6
●
F2
19“
safe
Model
Order no.
UP
with switch
03.534.006.1
1 Unit
[mm]
●
Power Strips And Managed Power Strips
Liebert MP Advanced Power Strips
Provide Easy-To-Use Distribution, with Monitoring and Control For IT Rack/Enclosure Applications
Specifications
INPUT (Rated)
Form Factor
Voltage
Connection(s)
Current
Phase
Type
OUTPUT (Rated)
Quan Length
Connection(s)
Voltage Current Phase
Monitoring
Liebert
Type
Quan
LCD/LED
Part Number
MP-M5109
Liebert MP Advanced Power Strips (Monitoring)/MP-M Series
Rckmnt / 1U
120
15
1PH
5-15P
1
6’
120
15
1PH
5-15/20R
10
LCD
Rckmnt / 1U
120
20
1PH
5-20P
1
6’
120
20
1PH
5-15/20R
10
LCD
MP-M5110
Rckmnt / 1U
120
20
1PH
L5-20P
1
6’
120
20
1PH
5-15/20R
10
LCD
MP-M5111
Rckmnt / 1U
120
30
1PH
L5-30P
1
6’
120
30
1PH
5-15/20R
10
LCD
MP-M5112
Rckmnt / 1U
200-240
20
1PH
L6-20P
1
6’
200-240
20
1PH
IEC-C13
10
LCD
MP-M5113
Rckmnt / 1U
200-240
30
1PH
L6-30P
1
6’
200-240
30
1PH
IEC-C13
10
LCD
MP-M5114
Vert / 33.25”
120
15
1PH
5-15P
1
10’
120
15
1PH
5-15/20R
12
LCD
MP-M5115
Vert / 33.25”
120
20
1PH
5-20P
1
10’
120
20
1PH
5-15/20R
12
LCD
MP-M5116
Vert / 33.25”
120
20
1PH
L5-20P
1
10’
120
20
1PH
5-15/20R
12
LCD
MP-M5117
Vert. / 50.75”
120
20
1PH
5-20P
1
10’
120
20
1PH
5-15/20R
24
LCD
MP-M5118
Vert. / 50.75”
120
20
1PH
L5-20P
1
10’
120
20
1PH
5-15/20R
24
LCD
MP-M5034
Vert. / 50.75”
120
30
1PH
L5-30P
1
10’
120
30
1PH
5-15/20R
24
LCD
MP-M5035
Vert. / 57.75”
200-240
20
1PH
L6-20P
1
10’
200-240
20
1PH
IEC-C13
24
LCD
MP-M5036
Vert. / 57.75”
200-240
30
1PH
L6-30P
1
10’
200-240
30
1PH
IEC-C13
24
LCD
MP-M5037
Vert. / 68.25”
120/208
20
3PH
L21-20P
1
10’
208 & 120
20
1PH
IEC-C13+5-20R
24+2
LED
MP-M5119
Liebert MP Advanced Power Strips (Controlled)/MP-C Series
Rckmnt / 1U
120
15
1PH
5-15P
1
6’
120
15
1PH
5-15/20R
8
LCD / LED
MP-C5120
Rckmnt / 1U
120
20
1PH
5-20P
1
6’
120
20
1PH
5-15/20R
8
LCD / LED
MP-C5121
Rckmnt / 1U
120
20
1PH
L5-20P
1
6’
120
20
1PH
5-15/20R
8
LCD / LED
MP-C5122
Rckmnt / 1U
120
30
1PH
L5-30P
1
6’
120
30
1PH
5-15/20R
8
LCD / LED
MP-C5123
Rckmnt / 1U
200-240
20
1PH
L6-20P
1
6’
200-240
20
1PH
IEC-C13
8
LCD / LED
MP-C5124
Rckmnt / 1U
200-240
30
1PH
L6-30P
1
6’
200-240
30
1PH
IEC-C13
8
LCD / LED
MP-C5125
Vert. / 68.25”
120
20
1PH
5-20P
1
10’
120
20
1PH
5-15/20R
20+1
LCD / LED
MP-C5147
Vert. / 68.25”
120
20
1PH
L5-20P
1
10’
120
20
1PH
5-15/20R
20+1
LCD / LED
MP-C5148
Vert. / 68.25”
120
30
1PH
L5-30P
1
10’
120
30
1PH
5-15/20R
20+1
LCD / LED
MP-C5131
Vert. / 68.25”
200-240
20
1PH
L6-20P
1
10’
200-240
20
1PH
IEC-C13
20+1
LCD / LED
MP-C5132
Vert. / 68.25”
200-240
30
1PH
L6-30P
1
10’
200-240
30
1PH
IEC-C13
20+1
LCD / LED
MP-C5133
Vert. / 68.25”
120/208
20
3PH
L21-20P
1
10’
120
20
1PH
5-15/20R
21
LCD / LED
MP-C5134
Vert. / 68.25”
120/208
20
3PH
L21-20P
1
10’
208
20
3PH/1PH NEMA L21-20 + IEC320 C13
1 + 18
LCD / LED
MP-C5135
Vert. / 68.25”
120/208
30
3PH
L21-30P
1
10’
208
30
3PH/1PH NEMA L21-20 + IEC320 C13
1 + 18
LCD / LED
MP-C5136
Liebert MP Advanced Power Strips (Access Series)/MP-S Series
Form Factor
Input Voltage
Input Plug
Length
PDU’s Supported
Installed Network Cards
Installed RS232 Cards
Part Number
Rckmnt / 1U
120
5-15P
6’
4 (Expand to 8)
1
1
MP-S5137-125
Rckmnt / 1U
200-240
IEC-C14
6’
4 (Expand to 8)
1
1
MP-S5137-230
Rckmnt / 1.5U
120
5-15P
6’
4 (Expand to 20)
1
1
MP-S5138-125
Rckmnt / 1.5U
200-240
IEC-C14
6’
4 (Expand to 20)
1
1
MP-S5138-230
Rckmnt / 2U
120
5-15P
6’
4 (Expand to 32)
1
1
MP-S5139-125
Rckmnt / 2U
200-240
IEC-C14
6’
4 (Expand to 32)
1
1
MP-S5139-230
Expansion Module
Form Factor
Card
Type
Input Voltage
Connection
Part Number
RS-232
NA
4X RS232
MP-DS74
47
Liebert Products
Liebert has consistently developed the power, cooling and monitoring technologies
that IT organizations rely on to manage growth and integrate new technologies.
From the first precision-cooling system in 1965, to the first enclosed protection
system in 1994, to the first high-density cooling system in 2002, Liebert
technology has given IT organizations the reliability and flexibility they need
to succeed.
The Liebert Adaptive Architecture is a combination of power, cooling and
monitoring technologies that provide higher availability, flexibility and the lowest
total cost of ownership across your entire enterprise.
Adaptive Benefits
Higher Availability
Cooling
I
I
I
I
I
Power
I
I
I
I
Monitoring
I
I
I
Flexibility
Optimal redundancy
Two refrigeration circuits
Open architecture
Extended fail-safe operation
High density cooling without
introducing water in the room or rack
I
Uses fewer parts to reach ideal capacity
Optimal redundancy through flexibility
to adapt to different tier levels of
availability
Power distribution supports quick
additions and changes, high availability
schemes, and circuit level monitoring
Multiple system configurations provide
flexibility to fit site needs
I
Data from unit level to system level
Planned work vs. rapid response
Forensic analysis prevents failures
I
I
I
I
I
I
Reconfigurable space & depth
Structured cable environment
Optimal airflow
I
I
I
I
I
I
I
I
I
48
Lower Total Cost of Ownership
I
I
Racks
Extreme Density cooling on demand
Retrofit any floor, any space, any time
Extensive configuration options
Significant energy savings
Operating modulation for optimal
energy consumption
Cooling at the source
Minimal to zero floor space consumed
Extends current infrastructure into the
future
Change tiers of protection
Growth without cable mess
Circuit control and monitoring
I
Capital and operating costs per kVA
drop significantly with increase in
module size
Configurable: for rack, room or
enterprise
Easily maneuver with the IT
environment
Protocol independent
I
Prevent or reduce costly downtime
duration as a result of a mature
monitoring strategy
T Slot channels in frame extrusion
allow for simple and infinitely
adjustable mounting
Adapts to support changes in
structured cabling
I
Minimize downtime by utilizing racks
that easily expand with changing
requirements
4-Step Power Protection System Guide
Selecting the proper power protection system can be accomplished in
four easy steps:
1) Identify the application or equipment you want to protect.
2) Determine how much backup time is required.
• Desktop — Typically 5 minutes is adequate to ride through brief
outages and to allow safe automatic shutdown of most computer equipment.
• Network Closet — Equipment such as high speed routers and
VoIP enabled switches may require up to an hour or more of
backup time.
• Computer Room — Higher power consumption and extended
backup times typical of computer rooms means a generator
backup can be a very cost effective solution.
3) Select output distribution options to match the loads you are
protecting.
• Desktop — These applications usually operate from 120VAC and
draws up to 15A or 20A. Standard power strips are available if
you need to add additional output receptacles.
• Network Closet — Connections vary from 15A receptacles to
hardwire connections requiring branch rated circuit breakers.
Larger equipment often operates at voltages of 208 or 240V
rather than 120V.
• Computer Rooms — Computer rooms are usually spread across
many racks so configurable output distribution or circuit breaker
distribution panels are most often used.
Desktop
Network Closet
Computer Room
Desktop PC
Router
Servers
Network Terminal
Hub
Blade Server
VoIP Switch
Storage Array
Scanner
Print Server
Workstation
300 VA
1 kVA
3 kVA
10 kVA
30 kVA
Liebert PSI
Line Interactive Technology
300 — 3kVA
Liebert GXT2
On Line/Double Conversion Technology
500 VA — 10 kVA
Liebert Nfinity, Liebert NX
On Line/Double Conversion Technology
4 k VA — >30 kVA
4) Select Maintenance Bypass to provide ease of service without
interrupting power to your load.
• Desktop — Liebert MicroPOD devices integrate the maintenance
bypass function with output distribution for desktop and clientside side applications.
• Network Closet — Bypass options for network equipment
include the MicroPOD’s as well as integrated bypass and output
distribution options on the larger Liebert GXT product lines.
• Computer Rooms — Larger UPS for computer room applications
offer maintenance bypass options.
49
Single Phase Line Interactive UPS
Liebert PowerSure PSI UPS (1000VA - 3000VA)
Proven UPS Protection That Will Keep Your Network Up And Running
Specifications
Model Number
Model Number with
Web Card Installed
POWER RATING: VA/W
DIMENSIONS: W x D x H
Unit inches
Unit (mm)
WEIGHT: lbs (kg) Unit
INPUT AC PARAMETERS:
Surge Protection
Voltage Range Without
Battery Operation
Frequency Range
Input Power Cord
OUTPUT AC PARAMETERS:
Output Receptacles
PS1000RT2-120
PS1440RT2-120
PS1920RT2-120
PS2200RT2-120
PS3000RT2-120
PS1000RT2-120W
PS1440RT2-120W
PS1920RT2-120W
PS2200RT2-120W
PS3000RT2-120W
1000VA/750W
1440VA/1080W
1920VA/1500W
2200VA/1650W
3000VA/2250W
3.43 x 22 x 17
(87 x 557 x 430)
61.7 (28.0)
3.43 x 22 x 17
(87 x 557 x 430)
68.2 (31.0)
3.43 x 24.1 x 17
(87 x 612 x 430)
77.0 (35.0)
3.43 x 24.1 x 17
(87 x 612 x 430)
77.0 (35.0)
3.43 x 24.1 x 17
(87 x 612 x 430)
81.6 (37.0)
10 ft. (3m) attached,
w/NEMA L5-30 P
10 ft. (3m) attached,
w/NEMA L5-30 P
570J
78VAC - 150VAC, configurable
10 ft. (3m) attached,
w/NEMA 5-15 P
10 ft. (3m) attached,
w/NEMA 5-15 P
(8) NEMA 5-15 R
(8) NEMA 5-15 R
45 - 65 Hz (±0.1 Hz)
10 ft. (3m), attached,
NEMA 5-20 P
(6) NEMA 5-15 R
(6) NEMA 5-15 R
2) NEMA 5-20 R
(2) NEMA 5-20 R
T-Slot, accepts 15APlug T-Slot, accepts 15APlug
(4) NEMA 5-15 R
(2) NEMA 5-20 R
(1) NEMA L5-30 R
T-Slot, accepts 15APlug
Voltage (Normal mode)
110 / 120 / 127 VAC (configurable) ±10%
Voltage (Battery Mode)
110 / 120 / 127 VAC (configurable); ±5% before low battery warning; ±8% after low battery warning
Transfer Time
4-6 ms typical
Waveform
Sinewave
Frequency (Normal Mode)
45 - 65 Hz (±0.1 Hz)
Frequency (Battery Mode)
50 or 60 Hz (±5%); auto sensing
BATTERY PARAMETERS: Load% PS1000RT2-120(W) PS1440RT2-120(W)
PS1920RT2-120(W)
PS2200RT2-120(W) PS3000RT2-120(W)
Internal Battery Runtime 20%
65 min.
45 min.
52 min.
47 min.
47 min.
40%
37 min.
24 min.
25 min.
23 min.
22 min.
60%
24 min.
14 min.
15 min.
13 min.
14 min.
80%
16 min.
9 min.
10 min.
8 min.
9 min.
100%
11 min.
5 min.
6 min.
5 min.
6 min.
Recharge Time
4 hours to 90% of rated capacity, after full discharge into resistive load
EXTERNAL BATTERY CABINET
PS2-48VBATT
PS2-48VBATT
PS2-72VBATT
PS2-72VBATT
PS2-72VBATT
MODEL NUMBER:
Internal Battery Runtime + 1 External Battery Cabinet
50%
119 min.
72 min.
105 min.
99 min.
67 min.
100%
46 min.
30 min.
43 min.
40 min.
29 min.
Internal Battery Runtime + 2 External Battery Cabinets
50%
209 min.
133 min.
163 min.
150 min.
129 min.
100%
98 min.
56 min.
89 min.
77 min.
52 min.
Internal Battery Runtime + 3 External Battery Cabinets
50%
274 min.
209 min.
237 min.
222 min.
168 min.
100%
136 min.
95 min.
128 min.
120 min.
88 min.
Internal Battery Runtime + 4 External Battery Cabinets
50%
305 min.
257 min.
281 min.
274 min.
222 min.
100%
188 min.
125 min.
150 min.
144 min.
118 min.
50
Single Phase Line Interactive UPS
Liebert PowerSure PSI UPS (1000VA - 3000VA) Continued
Specifications Continued
Model Number
Model Number with
Web Card Installed
ENVIRONMENTAL:
Operating Temperature
Storage Temperature
Relative Humidity
Operating Altitude
Audible Noise
AGENCY:
Safety
Surge Immunity
Emissions (RFI/EMI)
Transportation
PS1000RT2-120
PS1440RT2-120
PS1920RT2-120
PS2200RT2-120
PS3000RT2-120
PS1000RT2-120W
PS1440RT2-120W
PS1920RT2-120W
PS2200RT2-120W
PS3000RT2-120W
+32°F to + 104°F (0°C to + 40°C)
+5°F to + 104°F (-15°C to + 40°C)
0% to 95%, non-condensing
Up to 10,000 ft. (3000m) at 95°F (35°C) without derating
<40 dBA, internal fan(s) off
<40 dBA, internal fan(s) off
<50 dBA, internal fan(s) on
<60 dBA, internal fan(s) on
UL 1778, c-UL Listed
IEEE 587, Category A
FCC Part 15, Class B
FCC Part 15, Class A
ISTA Procedure 1A Certification
51
Single Phase On-Line UPS
(Double Conversion)
Liebert GXT2U (500VA - 3kVA)
An On-Line UPS With Proven Reliability, Custom Configurability, Internal Batteries All In A Compact 2U Package
Specifications
Model Number
GXT2-500RT120
GXT2-700RT120
GXT2-1000RT120
Model Rating VA/W
500/350
700 / 490
1000 / 700
1500 / 1050
Dimensions: in (mm)
3.5 x 21.5 x 17 in.
3.5 x 21.5 x 17 in.
3.5 x 21.5 x 17 in.
3.5 x 21.5 x 17 in.
(89 x 546 x 432 mm)
(89 x 546 x 432 mm)
(89 x 546 x 432 mm)
(89 x 546 x 432 mm)
49 lbs. (22 kg)
49 lbs. (22 kg)
50 lbs. (23 kg)
51 lbs. (23 kg)
WxDxH
Weight: lbs. (kg)
GXT2-1500RT120
Input AC Parameters
Voltage Range
120 VAC nominal, (60 to 140VAC Variable based upon output load)
Frequency
Input Power Cord
40 - 70 Hz; Auto Sensing
6 ft. attached, w/ NEMA
6 ft. attached, w/ NEMA
10 ft. attached, w/ NEMA
10 ft. attached, w/ NEMA
5-15 plug
5-15 plug
5-15 plug
5-15 plug
(4) NEMA 5-15R
(4) NEMA 5-15R
(4) NEMA 5-15R
(4) NEMA 5-15R
Output AC Parameters
Output Receptacles
Voltage
100/110/115/120/127 (user configurable) VAC; ±3%
Frequency
50 Hz or 60 Hz
Waveform
Sinewave
GXT 2U Runtime in Minutes
20% Load
181 minutes
115 minutes
87 minutes
53 minutes
40% Load
83 minutes
58 minutes
34 minutes
28 minutes
60% Load
53 minutes
35 minutes
19 minutes
15 minutes
80% Load
36 minutes
24 minutes
13 minutes
10 minutes
100% Load
28 minutes
17 minutes
11 minutes
7 minutes
Recharge Time
5 Hours to 95% capacity after full discharge into 100% load
Agency
Safety
UL 1778; c-UL Listed (Flame Retardant Batteries, suitable for Computer Room Applications)
RFI/EMI
FCC Part 15, Subpart B, Class A
Surge Immunity
IEEE 587 Category A & B
Transportation
ISTA Procedure 1A
Model Number
GXT2-2000RT120
GXT2-3000RT120
Model Rating VA/W
2000 / 1400
3000 / 2100
Dimensions: in (mm)
3.5 x 21.5 x 17 in.
3.5 x 24.2 x 17 in.
(89 x 546 x 432 mm)
(89 x 615 x 432 mm)
54 lbs. (24kg)
69 lbs. (31kg)
WxDxH
Weight: lbs. (kg)
Input AC Parameters
Voltage Range
120 VAC nominal, (60 to 140VAC Variable based upon output load)
Frequency
Input Power Cord
40 - 70 Hz; Auto Sensing
10 ft. attached, w/ NEMA 5-20 plug
10 ft. attached, w/ NEMA L5-30 plug
Output AC Parameters
Output Receptacles
(4) 5-20 T-Slot receptacles
(4) NEMA 5-15R
(1) NEMA L5-30R on 12 inch cord
Voltage
100/110/115/120/127 (user configurable) VAC; ±3%
Frequency
50 Hz or 60 Hz
Waveform
Sinewave
GXT 2U Runtime in Minutes
20% Load
33 minutes
46 minutes
40% Load
19 minutes
21 minutes
60% Load
12 minutes
11 minutes
80% Load
8 minutes
8 minutes
100% Load
6 minutes
5 minutes
Recharge Time
5 Hours to 95% capacity after full discharge into 100% load
Agency
Safety
UL 1778; c-UL Listed (Flame Retardant Batteries, suitable for Computer Room Applications)
RFI/EMI
52
FCC Part 15, Subpart B, Class A
Surge Immunity
IEEE 587 Category A & B
Transportation
ISTA Procedure 1A
Single Phase On-Line UPS
(Double Conversion)
Liebert GXT2U (500VA - 3kVA) Continued
Specifications Continued
UPS MODEL:
500VA
BATTERY CABINET MODEL:
Internal Battery Runtime + 1 External Battery Cabinet
50%
267 min.
100%
115 min.
Internal Battery Runtime + 2 External Battery Cabinets
50%
534 min.
100%
231 min.
Internal Battery Runtime + 3 External Battery Cabinets
50%
801 min.
100%
346 min.
Internal Battery Runtime + 4 External Battery Cabinets
50%
1068 min.
100%
462 min.
700VA
1kVA
GXT2-48VBATT
1.5kVA
2000VA
3000VA
GXT2-72VBATT
176min.
68 min.
100 min.
44 min.
80 min.
28 min.
42 min.
18 min.
64 min.
20 min.
352 min.
136 min.
200 min.
88 min.
160 min.
56 min.
98 min.
42 min.
128 min.
40 min.
528 min.
204 min.
300 min.
132 min.
140 min.
60 min.
140 min.
60 min.
192 min.
60 min.
704 min.
272 min.
400 min.
304 min.
320 min.
112 min.
210 min.
90 min.
256 min.
80 min.
53
Single Phase On-Line UPS
(Double Conversion)
Liebert GXT2 (6kVA - 10kVA)
Rack/Tower Configurable UPS For High Power Network Rack Applications
Specifications
Model Number
Model Rating
DIMENSIONS Unit W x D x H in. (mm)
WEIGHT lbs (kg) Unit
INPUT AC PARAMETERS
Nominal Operating Frequency
Factory Default VAC
L1-L2 Factory Default Input Phase Angle
Allowable Input Phase Angle
Factory Default L1-N, L2-N VAC
Input Frequency w/o Battery Operation
OUTPUT AC PARAMETERS
Factory Default VAC
L1-L2 Factory Default Output Phase Angle
Allowable Output Phase Angle
Factory Default L1-N, L2-N VAC
User Configurable L1-N, L2-N VAC
Frequency
Waveform
Overload Rating
LIEBERT GXT2 6 KVA
GXT2-6000RT208
4200W/5200VA at 127/220 (120 or 240 degrees)
4200W/5200VA at 120/208 (120 or 240 degrees)
4200W/6000VA at 120/240 (180 degrees)
4200W/6000VA at 115/230 (180 degrees)
3780W/5400VA at 110/220 (180 degrees)
3360W/4800VA at 100/200 (180 degrees)
6.9 x 24.2 x 16.9 (176 x 615 x 430)
67 (30.3)
LIEBERT GXT2 10 KVA
GXT2-10000RT208
8000W/8660VA at 127/220 (120 or 240 degrees)
8000W/8660VA at 120/208 (120 or 240 degrees)
8000W/10000VA at 120/240 (180 degrees)
8000W/10000VA at 115/230 (180 degrees)
7200W/9000VA at 110/220 (180 degrees)
6400W/8000VA at 100/200 (180 degrees)
10.5 x 26.0 x 16.9 (267 x 660 x 430)
109 (49.3)
50 or 60 Hz (Factory Default = 60)
120/208 VAC at 120 degrees
120 degrees
120, 180, 240 degrees, Auto-sensing on application of AC (Restrictions for L-N voltages other than 120 VAC)
120 VAC nominal
40 - 70 Hz
120/208 VAC @ 120 degrees
120 degrees
120, 180, 240 degrees Auto-sensing on initial application of input AC
120 VAC nominal
100/110/115/120/127 VAC, ±3%
50 Hz or 60 Hz, Nominal
Sinewave
200% for 8 cycles; 130% for 10 seconds
200% for 8 cycles then shutdown; 130% for
with transfer to bypass
60 seconds with transfer to bypass
ENVIRONMENTAL
Operating Temp
Storage Temp
Relative Humidity
Operating Elevation
Storage Elevation
Audible Noise
GXT2 6/10 RUNTIME IN MINUTES
20% Load
40% Load
60% Load
80% Load
100% Load
AGENCY
Safety
RFI/EMI
Surge Immunity
Transportation
+32°F to +104°F (0°C to +40°C)
+5°F to +122°F (-15°C to +50°C)
0% to 95%, non-condensing
Up to 10,000 ft. (3000m) at 104°F (40°C) without derating
50,000 ft. (15,000 m) maximum
<55 dBA, at 1 meter from the rear; <50 dBA, at 1 meter from the front or sides
38
18
11
7
5
52
22
13
9
6
UL 1778, c-UL Listed (Suitable for computer room applications)
FCC Part 15, Subpart B, Class A
IEEE/ANSI C62.41 Category A & B
ISTA Procedure 1A
Note: Part Numbers GXT2-6000RT208 and GXT2-10000RT208 do not include internal battery kits. When calculating total unit weight, add weight of internal batteries.
UPS MODEL:
6000VA
BATTERY CABINET MODEL:
GXT2-144RTVBATT
Internal Battery Runtime + 1 External Battery Cabinet
50%
34 min.
100%
14 min.
Internal Battery Runtime + 2 External Battery Cabinets
50%
58 min.
100%
25 min.
Internal Battery Runtime + 3 External Battery Cabinets
50%
82 min.
100%
36 min.
Internal Battery Runtime + 4 External Battery Cabinets
50%
105 min.
100%
47 min.
54
10000VA
GXT2-288RTVBATT
39 min.
17 min.
66 min.
28 min.
92 min.
41 min.
119 min.
54 min.
Single Phase On-Line UPS And Power Output Distribution
(Double Conversion)
Liebert GXT2 (6kVA - 10kVA) Continued
Specifications Continued
LIEBERT GXT2 6 KVA
INTERNAL BATTERY
Model Number
WEIGHT lbs (kg)
Type
Quantity x V x Rating
Battery Mfg / Part #
Recharge Time
OPTIONAL EXTENDED BATTERY CABINET
Model Number
DIMENSIONS W x D x H in.(mm)
WEIGHT lbs (kg) Unit
BATTERY PARAMETERS
Type
Qty x V x Rating
Battery Mfg / Part #
ENVIRONMENTAL
Operating Temp
Storage Temp
Relative Humidity
Operating Elevation
Storage Elevation
AGENCY
Safety
RFI/EMI
Transportation
LIEBERT GXT2 10 KVA
GXT2-144BATKIT (one required)
GXT2-288RTBKIT (two required)
79 (35.8) (one required)
78.1 (35.5) (two required)
Valve-regulated, non-spillable, flame retardant, lead acid
12 x 12V x 9.0 AH (one required)
12 x 12V x 9.0 AH (two required)
Yuasa / REW 45-12 FR
6 Hours to 90% capacity after full discharge into 100% load
GXT2-144VBATT
3.5 x 24.2 x 16.9 (87 x 618 x 430)
93.6 (42.5)
GXT2-288RTVBATT
7.0 x 26.0 x 16.9 (178 x 660 x 430)
41.6 (18.9)
Valve-regulated, non-spillable, flame retardant, lead acid
12 x 12V x 9.0 AH per kit
12 x 12V x 9.0 AH per kit (two required)
Yuasa / REW 45-12 FR
+32°F to +104°F (0°C to +40°C)
+5°F to +122°F (-15°C to +50°C)
0% to 95%, non-condensing
Up to 10,000 ft. (3000m) at 104°F (40°C) without derating
50,000 ft. (15,000m) maximum
UL 1778, c-UL Listed (Suitable for computer room applications)
FCC Part 15, Subpart B, Class A
ISTA Procedure 1A
Note: Part Numbers GXT2-6000RT208 and GXT2-10000RT208 do not include internal battery kits. When calculating total unit weight, add weight of internal batteries.
Part Number
PD-HDWR
PD-HDWR-MBS
PD-001
PD-002
PD-003
PD-004
PD-005
PD-006
PD-007
POWER OUTPUT DISTRIBUTION (POD)
LIEBERT GXT2 6 KVA
Rating
Input / Output
Part Number
30A, No Bypass
Input - Hardwired
PD-101
Output - Hardwired
30A, With Bypass
Input - Hardwired
PD-102
Output - Hardwired
30A, With Bypass
Input - L14-30P
Output - (1) L6-30R, (1) L14-30R,
(4) 5-15/20R T-slot
30A, With Bypass
Input - L14-30P
Output - (2) L6-20R, (2) 5-15/20R
T-slot
30A, With Bypass
Input - L14-30P
Output - (2) L6-30R, (4) 5-15/20R
T-slot
30A, With Bypass
Input - L14-30P
Output - (4) EN60320 / C19
30A, With Bypass
Input - L14-30P
Output - (4) L5-20R, (2) L5-30R
30A, With Bypass
Input - L14-30P
Output - (4) L5-20R, (2) L6-30R
30A, With Bypass
Input - L14-30P
Output (4) L6-20R
LIEBERT GXT2 10 KVA
Rating
Input / Output
30A
Output - (8) 5-20R, T-type
(2) L6-30R
30A
Output - (4) 5-20R, T-type
(4) NEMA L6-20R
55
Maintenance Bypass
Liebert 2U MicroPOD
The Liebert 2U MicroPOD (Power Output Distribution) is a maintenance bypass option for the Liebert
PowerSure PSI and GXT2U UPS rated 3 kVA and below. It allows removal of the UPS without powering down the
connected equipment. The MicroPODs are available in several receptacle combinations, but certain PODs only
work with certain UPS models (see MicroPOD Compatibility Chart) due to UPS plug differences. The 2U POD’s
can be installed on the floor or mounted to a GXT 2U UPS using the included mounting brackets. The 2U POD
also includes brackets for mounting the POD into a standard 19” rack. The rack mounting brackets can be
installed in four positions on the POD; this allows the output wiring to face the front, rear, top, or bottom in
the rack enclosure.
2U MicroPODs are provided with a 10-foot input cord for connection to utility and contain a 6-foot cord for
connection to the UPS. Lamps on the front panel indicate utility and UPS power availability. MicroPODs are UL
and c-UL Listed. Models MP2-210K and MP2-220L are CE marked (not UL Listed).
Dimensions: All models are 3.5” X 3.5” X 15.5”
Specifications
Part Number
Plug to Utility
120V UL Listed MicroPODs
MP2-115A
5-15P
MP2-120C
5-20P
MP2-130C
L5-30P
MP2-130E
L5-30P
MP2-130P
L5-30P
MP2-115HW
Hardwired
MP2-120HW
Hardwired
MP2-130HW
Hardwired
230V CE Marked MicroPODs
MP2-210K
EN60320/C14
MP2-220L
EN60320/C20
56
Receptacle to
UPS Input
Plug to
UPS Output
MicroPOD
Output Receptacles
5-15R
5-20R
L5-30R
L5-30R
L5-30R
5-15R
5-20R
5-30R
5-15P
5-20P
L5-30P
L5-30P
L5-30P
5-15P
5-20P
5-30P
(8)5-15R
(8)5-20R (T-Slot)
(8)5-20R (T-Slot)
(2)5-15R, (4) 5-20R (T-Slot), (1) L5-30R
(4) 5-15R, (2) L5-20R
Hardwired
Hardwired
Hardwired
EN60320/C13
EN60320/C19
EN60320/C14
EN60320/C20
(4) EN60320/C13
(4) EN60320/C13, (1)EN60320/C19
Maintenance Bypass
Liebert 2U MicroPOD Continued
Input Plug (to utility)
208 VAC
120 VAC
X
MP2-220L; (4) EN60320/C13, (1) EN60320/C19
MP2-210K; (4) EN60320/C13
MP220N; Hardwired OR (2) L6-20R, (2) L6-15R
MP2-130HW; Hardwired
MP2-120HW; Hardwired
MP2-115HW; Hardwired
MP2-130P; (4) 5-15R, (2) L5-20R
MP2-130E; (2) 5-15R, (1) L5-30R, (4) 5-15/20R
(T-Slot Type)
MP2-130C; (8) 5-15/20R (T-Slot Type)
MP2-120C; (8) 5-15/20R (T-Slot Type)
MicroPOD Compatibility Chart
UPS Models
Utility Voltage
UPS Station GXT 2U
700, 1000, 1500
120 VAC
2000
120 VAC
3000
120 VAC
700, 1000, 1500, 2000 230 VAC
3000
230 VAC
2700 VA
208 VAC
PowerSure PSI
1000, 1440
120 VAC
3000
120 VAC
1000, 1440
230 VAC
3000
230 VAC
PowerSure PST
300, 500
120 VAC
500, 650
230 VAC
PowerSure PSP
300, 500, 650
120 VAC
500, 650
230 VAC
PowerSure PSA
300, 500, 650, 1000
120 VAC
350, 500, 650, 1000
230 VAC
MP2-115A; (8) 5-15R
Specifications Continued
230 VAC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
5-15P
5-20P
L5-30P
Hardwired
L6-20P or
Hardwire
10A IEC
16A IEC
Receptacle Receptacle
57
Single Phase, Scalable, Redundant UPS
(Double Conversion)
Liebert Nfinity UPS (4 - 20 kVA)
Scalable 4 - 16 kVA
General & Environmental
Unit Rating
Units
kVA
kW
Conducted and Radiated EMC Levels
Compliant Safety Standards
Compliant Immunity Standards
Mechanical
Dimensions: Width
Dimensions: Depth
Dimensions: Height
Environmental
Operating Temperature (max)
Relative Humidity
Maximum Operating Altitude
Nominal Heat Dissipation
Input Data
Nominal Input Voltage
58
4
2.8
8
12
16
20
5.6
8.4
11.2
14
FCC Part 15, Class A
UL 1778; c-UL (Flame Retardant Batteries, suitable for Computer Room Applications)
IEEE C62.41, Category B
Units
8 Bay
20 (508)
28 (711)
41 (1041)
In (mm)
Units
F (C)
Ft. (M)
BTU/Hr
Power Factor
Input Frequency (nominal)
Input Frequency Range
Units
VAC
VAC
Cos 0/
Hz
Hz
Battery Module
Battery Capacity
Autonomy Time (full load)
Units
A/hr
Mins
Maximum Charge Current (full load)
Nominal Voltage
Recharge Time
A
VDC
Hrs
Nfinity Runtimes in Minutes
(Min. / Max. Configurable Runtime)
20% Load
40% Load
60% Load
80% Load
100% Load
8-Bay Models
Nfinity Runtimes in Minutes
(Min. / Max. Configurable Runtime)
20% Load
40% Load
60% Load
80% Load
100% Load
12-Bay Models
Scalable 12 - 20 kVA
4
1062
12 Bay
20 (508)
28 (711)
54 (1372)
8
12
32°-104° (0°-40°)
0-95% non-condensing
10,000 (3,000)
2124
3186
16
20
4248
5307
170 to 276
110-276 (variable, based on output load)
>.98
60
40-70
9
7
(With an equal number of Battery & Power Modules,
in a non-redundant configuration)
3
120
3-5 (to 90% capacity)
4
8
12
16
20
55 / 420
26 / 213
14 / 128
11 / 109
7 / 79
26 / 213
11 / 109
14 / 52
9 / 40
7 / 31
14 / 128
14 / 52
8 / 34
10 / 21
7 / 16
9 / 93
9 / 40
10 / 21
10
7
4
8
12
16
20
55 / 659
26 / 337
14 / 205
9 / 151
7 / 128
26 / 337
9 / 151
14 / 90
9 / 69
7 / 55
14 / 205
14 / 90
8 / 59
10 / 41
7 / 32
9 / 151
9 / 69
10 / 41
9 / 25
7 / 19
7 / 128
7 / 55
7 / 32
7 / 19
7 / 12
Single Phase, Scalable, Redundant UPS
(Double Conversion)
Liebert Nfinity UPS (4 - 20 kVA) Continued
Specifications Continued
Output Data
Units
Output Voltage
VAC
Voltage Regulation
%
Voltage Transient Response (100% step load) %
Voltage Stability (100% step load)
%
Recovery Time
msec
Voltage distortion:
%
Output Frequency
Efficiency at 100% load
Output Overload Capability
4 - 20 kVA Systems
208/120 or 240/120
±3
±7
±7
96
<3 THD, linear load
<7 THD, non-linear load
60
89
110-125% for 10 min
126-150% for 10 sec
>151-200% for 2 cycles
Hz
%
%
Model Number Designation: 4 - 20 kVA Single-Phase Unit
N
1
04
S
Product
Family
Frame Type
kVA Rating
Unit Type
N=Nfinity
01
No. Battery
Modules
12
Output Voltage
6
Output
Frequency
1 = 8 bay frame
with xfmr
04 = 4 kVA
S = Standard
(non-redundant)
01 = 1 battery
module
12 = 208/120,1x1 5 = 50Hz
2 = 12 bay frame
with xfmr
08 = 8 kVA
C = Redundant;
Power and Controls
02 = 2 battery
modules
00 = Extended
Battery
Cabinet
9 = Extended
Battery Cabinet
12 = 12 kVA
F = Full Redundant;
Power, Battery, And
Controls
03 = 3 battery
modules
B = 20kVA Frame
Requiring
External Input
16 = 16 kVA
E = Extended
Battery Cabinet
0
0
Bezel Color
Sheet Metal Color
0 = Charcoal Grey
0 = Black
6 = 60Hz
0 = Extended
Battery
Cabinet
04 = 4 battery
modules
20 = 20 kVA
05 = 5 battery
modules
00 = Extended
Battery
Frame
06 = 6 battery
modules
07 = 7 battery
modules
08 = 8 battery
modules
09 = 9 battery
modules
10 = 10 battery
modules
11 = 11 battery
modules
12 = 12 battery
modules
59
Single Phase, Scalable, Redundant UPS
(Double Conversion)
Liebert Nfinity UPS (4 - 20 kVA) Continued
Nfinity Maintenance Bypass with Configurable Output Distribution
Specifications
Part No.*
Nfinity Maintenance Bypass Frame with Factory Installed Output Distribution Options
Hardwired 16 kVA Bypass Cabinet w/ 120/120/208/240 V Output, 60Hz, w/ Isolation Transformer in Bypass Path
Hardwired 16 kVA Bypass Cabinet w/ 120/120/208 V or 120/120//240 V Output, 60 Hz, No Isolation Transformer in Bypass Path
Hardwired 20 kVA Bypass Cabinet w/ 120/120/208/240 V Output, 60Hz, w/ Isolation Transformer in Bypass Path
Hardwired 20 kVA Bypass Cabinet w/ 120/120/208 V or 120/120/240 V Output, 60 Hz, No Isolation Transformer in Bypass Path
Factory Installed Output Distribution Options (up to 10 positions may be selected)
Type of Output Receptacle
Hardwire Option (requires 2 slots, 1-1/2” & 2” knockouts)
Single Position Blanking Plate
15A Distribution
NEMA 5-15R2
NEMA L5-15R2
NEMA 6-15R2, 208V Only
NEMA 6-15R2, 240V Only
NEMA L6-15R2, 208V Only
NEMA L6-15R2, 240V Only
15A, 120V, Hardwire, 1 Pole Branch Rated Breaker
15A, 208V, Hardwire, 2 Pole Branch Rated Breaker
15A, 240V, Hardwire, 2 Pole Branch Rated Breaker
20A Distribution
NEMA 5-20R2 (T-Slot)
NEMA L5-20R
NEMA L6-20, 208V Only
NEMA L6-20R, 240V Only
NEMA L14-20R, 120/120/240V Only
20A, 120V, Hardwire, 1 Pole Branch Rated Breaker
20A, 208V, Hardwire, 2 Pole Branch Rated Breaker
20A, 240V, Hardwire, 2 Pole Branch Rated Breaker
30A Distribution
NEMA L5-30R
NEMA L6-30R, 208V Only
NEMA L6-30R, 240V Only
NEMA L14-30R, 120/120/240V Only
30A, 120V, Hardwire, 1 Pole Branch Rated Breaker
30A, 208V, Hardwire, 2 Pole Branch Rated Breaker
30A, 240V, Hardwire, 2 Pole Branch Rated Breaker
*Select from Option Code list to complete part number
60
NMB11xxxxxxxxxx
(up to 10 option codes)
NMB41xxxxxxxxxx
(up to 10 option codes)
NMB51xxxxxxxxxx
(up to 10 option codes)
NMB81xxxxxxxxxx
(up to 10 option codes)
Option Code
99
0
A
B
C
D
E
F
G
H
J
K
M
N
P
S
T
U
V
W
X
Y
1
2
3
4
Single Phase, Scalable, Redundant UPS
(Double Conversion)
Liebert Nfinity UPS (4 - 20 kVA) Continued
Nfinity Configurable Output Distribution
Specifications
Part No.*
Step One: Select Output Distribution Base
10 Output Options w/ 25 foot Flexible Conduit
10 Output Options w/ 12 foot Flexible Conduit
10 Output Options w/ 6 foot Flexible Conduit
8 Output Options w/ 25 foot Flexible Conduit
8 Output Options w/ 12 foot Flexible Conduit
8 Output Options w/ 6 foot Flexible Conduit
6 Output Options w/ 25 foot Flexible Conduit
6 Output Options w/ 12 foot Flexible Conduit
6 Output Options w/ 6 foot Flexible Conduit
PD111 xxxxxxxxxx
(up to 10 option codes)
PD112 xxxxxxxxxx
(up to 10 option codes)
PD113 xxxxxxxxxx
(up to 10 option codes)
PD211 xxxxxxxx
(up to 8 option codes)
PD212 xxxxxxxx
(up to 8 option codes)
PD213 xxxxxxxx
(up to 8 option codes)
PD311 xxxxxx
(up to 6 option codes)
PD312 xxxxxx
(up to 6 option codes)
PD313 xxxxxx
(up to 6 option codes)
Step Two: Select Factory Installed Output Distribution Options (up to 6, 8, or 10 positions may be selected depending on size of base selected)
Type of Output Receptacle
Option Code
Hardwire Option (requires 2 slots, 1-1/2” & 2” knockouts)
99
Single Position Blanking Plate
0
15A Distribution
NEMA 5-15R2
A
NEMA L5-15R2
B
NEMA 6-15R2, 208V Only
C
NEMA 6-15R2, 240V Only
D
NEMA L6-15R2, 208V Only
E
NEMA L6-15R2, 240V Only
F
15A, 120V, Hardwire, 1 Pole Branch Rated Breaker
G
15A, 208V, Hardwire, 2 Pole Branch Rated Breaker
H
15A, 240V, Hardwire, 2 Pole Branch Rated Breaker
J
20A Distribution
NEMA 5-20R2 (T-Slot)
K
NEMA L5-20R
M
NEMA L6-20, 208V Only
N
NEMA L6-20R, 240V Only
P
NEMA L14-20R, 120/120/240V Only
S
20A, 120V, Hardwire, 1 Pole Branch Rated Breaker
T
20A, 208V, Hardwire, 2 Pole Branch Rated Breaker
U
20A, 240V, Hardwire, 2 Pole Branch Rated Breaker
V
30A Distribution
NEMA L5-30R
W
NEMA L6-30R, 208V Only
X
NEMA L6-30R, 240V Only
Y
NEMA L14-30R, 120/120/240V Only
1
30A, 120V, Hardwire, 1 Pole Branch Rated Breaker
2
30A, 208V, Hardwire, 2 Pole Branch Rated Breaker
3
30A, 240V, Hardwire, 2 Pole Branch Rated Breaker
4
*Select from Option Code list to complete part number
61
Three Phase On-Line Digital UPS
(Double Conversion)
Liebert NX UPS (10 - 30 kVA)
The Next Generation Of UPS Technology To Power The Networked Economy
Specifications
Models
Nominal Power Rating At 0.8 PF
Input Parameters
Rectifier Type
Input Voltage*
Permissible Input Voltage Range
Input Frequency
Permissible Input Frequency Range
Input THDi At Nominal Voltage
Input Power Factor At Nominal Voltage
Power Walk-In
Battery
Battery Type
Nominal Battery Bus
End-Cell Voltage
DC Ripple Current
DC Ripple Voltage
Internal VRLA Battery
Output Parameters
Inverter Type
Output
kW
Output Voltage*
Output Voltage Regulation
Output Frequency
Output Frequency Regulation
Output THD At Nominal Voltage
Capability To Handle Step Load
Capability To handle Leading PF Load
Voltage Displacement With 100%
Unbalanced Load
Overload Conditions
Physical Parameters
Width
Depth
Height
Weight Without Battery
Color
Degree Of Protection For UPS Enclosure
Environmental Parameters
Storage Temperature Range
Operating Temperature Range
Relative Humidity
Maximum Altitude Above Mean Sea Level
*other voltages are available
kVA
NX 15
15
NX 20
20
NX 30
30
Seconds
PFC (Power Factor Corrected)
208/120v 3-ph, 4-w
+10% -20%
50 or 60
40 to 72
<4% without any additional hardware
>=0.99 without any additional hardware
5 to 20
VDC
VDC / Cell
%
%
Cells
VRLA (Valve Regulated Lead Acid) or Wet
288
Selectable from 1.67 to 1.80 (for VRLA)
<5
<1
144
VAC
VAC
Hz
Hz
%
kVA
10
8
VAC
%
Hz
%
%
%
deg
IGBT-based Active Star Control
15
20
12
16
208/120v 3-ph, 4-w
+/- 1%
50 or 60
+/- 0.05
1% (max) linear
<4% @ crest factor
100
1.00 to 0.95
120° +/- 1
30
24
% FL
125 for 10 minutes
150 for 1 minute
in/mm
in/mm
in/mm
lbs/kg
24/600
32.5/825
63/1600
450/205
450/205
550/250
550/250
PMS 877
IP 20 even with front door in open condition
°C
°C
%
m
-20 to 70 (UPS) & -20 to 30 (battery)
0 to 40 (UPS) & 0 to 20 (battery)
0 to 95 (non-condensing)
1000 (as per IEC 62040/3)
208 VAC Output UPS Models
Total Back-Up Time in Minutes — Internal Battery
Internal Battery Type
FJ
HJ
62
NX 10
10
NX 10
10 kVA
NX 15
15 kVA
NX 20
20 kVA
NX 30
30 kVA
26
45
14
26
9
17
9
Three Phase On-Line Digital UPS
(Double Conversion)
Liebert NX UPS (10 - 30 kVA) Continued
Specifications Continued
Model Number Designation: Liebert NX
38
SA
Product
System
Line
Configuration
NX UPS
SA = Single Module System
030
kVA Rating
010 = 10 kVA
015 = 15 kVA
020 = 20 kVA
030 = 30 kVA
External Battery Cabinet Model Number Designation
38
BP
030
R
Product
Number
Line
Battery Pack
kVA Rating
Of Cells
38-NX
010 = 10 kVA
015 = 15 kVA
020 = 20 kVA
030 = 30 kVA
R = 144
C
Rectifier
Input Voltage
O
Bypass
Input Voltage
C
C = 208/120V
0 = Single Input Module
C = Dual Input 208/120V
C = 208/120V
HJ
Battery Model
FJ = UPS12-100
HJ = UPS12-140
LJ = UPS12-170
MJ = UPS12-200
PJ = UPS12-270
RJ = UPS12-310
UJ = UPS12-370
WJ = UPS12-475
MX = HX205-FR
PX = HX300-FR
RX = HX330-FR
UX = HX400-FR
WX = HX500-FR
Output Voltage
00
Internal Battery
Model Code
00 = No Internal Battery
FJ = UPS12-100
HJ = UPS12-140
1
Number of Strings
Per Cabinet
B
Over Current
Protection Device
N
1 = 1 String
B = Circuit Breaker
N = None
Features
L
Mounting
Location
L = Left Side
R = Right Side
S = Stand Alone
Maintenance Bypass, Output Distribution, and Paralleling cabinets are also available in
matching enclosures for the Liebert NX.
Please consult the factory or your local Liebert Representative for help in configuring a
complete system that meets your particular needs.
63
Managed AC Power Distribution
Liebert FDC Power Distribution Cabinet
Power Distribution Solutions For A Better Way To Power Up Your Data Center
Specifications
Model Number Designation: Liebert FDC
FD
C
Input
Voltage
FD
1
2
C = 208V
F = 380V
U = 400V
G = 415V
44
4
4
Frame
No. of
Inputs
No. of
Panelboard
Panelboards Type1
SB
44 = 2 Door Bottom Cable Exit 1 = One 1 = One
54 = 3 Door Bottom Cable Exit, 2 = Two 2 = Two
w/Tie Breakers
4 = Four 3 = Three
64 = 2 Door Top Cable Entry
4 = Four
74 = 3 Door Top Cable Exit,
w/Tie Breakers
SB = Sq D Bolt-in
SP = Sq D Plug-in
GB = GE Bolt-in
GP = GE Plug-in
1
0
Panelboard
Main Breaker 2
Monitoring
1 = Standard
2 = High AIC
P = Plug-in
GE panelboards not available at 380-415V.
High AIC main breakers not available at 380-415V.
Physical Data — Liebert FDC
Width
Height
Weight
cm.
in.
cm.
in.
cm.
lbs.
Kg.
23.5
60
38
97
78.5
199
825
374
Domestic Packing
48
122
48
122
83
211
850
385
Export Packing
50
127
50
127
85
216
1000 454
Uncrated
64
Depth
in.
0= No Monitoring
1= Current
Monitoring
2= Enhanced
Monitoring
w/Modbus
3= BCMS
4= Current
Monitoring
w/BCMS
5= Enhanced
Monitoring
w/BCMS
65
High Density Cooling
Liebert XD Series Is Now Integrated With Knurr Racks
Adaptive Cooling Solutions For High Density Applications
Today’s data center technologies compound traditional
cooling problems. Blade servers, communications
switches and other electronics are being packed into
tighter and tighter spaces. Capacity that once filled an
entire room is now contained in a single rack-creating
extreme power and heat densities.
Business continuity professionals are demanding an
integrated solution—one that considers both room-level
and rack-level problems.
Traditional cooling solutions can’t keep up, and may
simply take up too much floor space to be practical.
66
Effective Solutions Need To Be Flexible.
They need to adapt with your facility. To meet all
these needs, the Liebert Adaptive Architecture for
infrastructure technologies ensures that power,
cooling and monitoring technologies can be
configured to meet changes in capacity, density and
criticality in data centers, computer rooms and
network closets. The Liebert XD Series brings this
adaptability to cooling solutions within your high
density environment.
A Cooling Solution For Every Application
Why The Liebert XD System
Makes So Much Sense
Available with Water or
Liebert XD Coolant.
Investing in a facility that utilizes a
higher rack density design offers a
significant cost savings advantage
in terms of building size and
energy usage.
The Liebert XD Coolant operates at
low pressure and becomes a gas at
room temperatures, making it ideal
for use around electronic equipment.
To meet the challenge of high heat
loads, the Liebert XD system delivers
cooling where it is needed most. It
also requires 27% lower energy
compared to typical solutions.
The flexible configuration of the
Liebert XD system modules allows
scalability for future growth, as well
as the ability to add redundant units
for maximum reliability in the most
mission-critical applications.
The Liebert XD approach significantly
Liebert XD
improves floor space utilization
High-Density
compared to an installation using
Rack Enclosure
(Coming Soon)
only floor-mounted cooling units.
Because of the cooling module size
CLOSED ARCHITECTURE
and placement, installing more XD
capacity uses virtually no additional
floor area.
The Liebert XD Piping system makes
it easy to plan and expand your
Liebert XD cooling system in
response to a growing heat load. The
key is to put the necessary piping in
place ahead of time and then add
cooling units and chillers as the need
arises for more cooling capability.
PUMPED REFRIGERANT
Liebert XDO
Overhead Cooling
Module
Liebert XDV
Top Mounted
Cooling Module
Liebert XDC
Coolant Chiller
Liebert XDH
Horizontal
Row Cooler
Liebert XD
CoolFrame
Module
Liebert XDP
Pumping Unit
OPEN ARCHITECTURE
Liebert XDWP
Coolant Distribution
Unit
Liebert XDWR
RackCooler
Liebert XDWK
High-Density Rack
Enclosure
The flexible connection piping allows
the cooling modules to be added or
repositioned without interruption in
operation as needs change.
WATER COOLANT
67
High Density Cooling
Liebert XDWK Server Rack Cooling (CoolTherm ®)
This high density solution provides heat exchangers with 10 kW to 35 kW within a closed cooling system
(air-to-water).
Features
Advantages
Cooling concept for IT applications with high
dissipated heat losses – for blade and rack servers.
" V35 high performance air-to-water heat
exchanger
" Channelled airflow in the entire rack
" Heat loss discharge via cooling water
" Fans with temperature-dependent speed
regulation
" Three-way valve for regulating the cooling
water flow (optional)
" Fans, n+1 redundant
" Alarm management
" Redundant high-performance power distribution for supplying servers (optional)
" User-friendly and service-optimised
" Autonomous server rack; independent from
environmental conditions
" Secure and reliable cooling capacity
" Highest packing density for high-performance
servers, consequently, up to 80% surface space
saving in the data center
" Reduced room and building requirements (thermal management, raised floors, room heights)
" Highest possible leakage safety with strict
separation of heat exchangers and server
installations
" Up to 30% improved cooling system
energy efficiency
" Highest planning security with freely selectable
scalability
" Significant TCO reduction
Options
UPS
Automatic door opener
Remote Monitoring
System
Fire detection and
extinguishing
Floor stand for IT rooms
without raised floors
The impressive Liebert XDWK (CoolTherm®)
technical concept :
Closed air circulation with V35 air/water heat
exchanger.
The dissipated heat is therefore not given off as an
additional load on the IT room (as is usual).
Connection is made installation-friendly to a
building or rack-own cold water system.
Operation and service are performed with no
difficulty whatsoever.
(Smaller cross-section shown)
Specifications
Cooling
Capacity
15 kW
68
Width
Height
Depth
Useable Height
Useable Depth
Weight
Water Content
Electrical Data
800 mm (31.50 in)
2200 mm (86.61 in)
1200 mm (47.24 in)
40 HU/U
740 mm (29.13 in)
310 kg (680 lbs)
7,9 kg (2.10 gal)
200 - 264V / 1400 W
High Density Cooling
Liebert XD Series Adaptive Cooling Solutions
Liebert XDWR Rack Cooler
Liebert XDC Chiller
Technical Data
Nominal Capacity, 60 Hz
Nominal Capacity, 50 Hz
Input Voltage
Full load amps
Height
Width
160 kW / 46 Ton
130 kW / 37 Ton
460 V, 3 ph, 60 Hz
380/420 V, 3 ph, 50 Hz
84 A @ 460 V, 3 ph, 60 Hz
78” (1981 mm)
74” (1879 mm)
Depth
34” (863 mm)
Weight, empty
2000 lbs (907 kg)
Full load amps
Height
Width
Depth
Weight, empty
Full load amps
Height
Width
Depth
Weight
8 kW / 2.2 Ton
1000 CFM (1700 m3/h)
120 V, 1 ph, 60 Hz
230 V, 1 ph, 60 Hz
1.5A @ 120V
55.5” (1410 mm)
15” (381 mm)
6” (152 mm)
70 lbs (32 kg)
Liebert XDWP Coolant
Distribution Unit
Liebert XDP
Pumping Unit
Technical Data
Nominal Capacity, 60 Hz
Nominal Capacity, 50 Hz,
Input Voltage
Technical Data
Nominal Capacity
Nominal Airflow
Input Voltage
160 kW / 46 Ton
140 kW / 40 Ton
208 V, 3 ph, 60 Hz
460 V, 3 ph, 60 Hz
380/420 V, 3 ph, 50 Hz
2.1 A @ 460 V, 3 ph, 60 Hz
3 A @ 380/420 V, 3 ph, 50 Hz
76” (1930 mm)
37” (940 mm)
30” (762 mm)
855 lbs (388 kg)
Technical Data
Nominal Capacity
Input Voltage
Full load amps
Height, unit only
Width
Depth
Weight, unit only
100 kW
460 V, 3 ph, 60 Hz
400V, 3 ph, 50 Hz
208 V, 3 ph, 60 Hz
4.3A @ 400V
2.5A @ 460V
78” (1981 mm)
38” (965 mm)
35” (889 mm)
750 lbs (340 kg)
69
High Density Cooling
Liebert XD Series Adaptive Cooling Solutions
Liebert XDH Horizontal Row Cooler
Technical Data
XDH20
Nominal Capacity 60 Hz
Nominal Airflow 60 Hz
Input Voltage
Power Draw
Full load amps
20 kW / 5.7 Ton
30 kW / 8.5 Ton
2500 CFM (4200 m3/h) 4000 CFM (6800 m3/h)
120 V, 1 ph, 60 Hz or 230 V, 1 ph, 60 Hz
500 W
1250 W
4.2 A @ 120V
10.5 A @ 120V
Number of Fans
Height (unit only)
Width
Depth
Weight
Options
XDH30
6
78” (1982 mm)
12” (300 mm)
42” (1066 mm)
350 lbs (160 kg)
Quick Connect Couplings (For Flexible Piping)
Condensate Detection (dry contacts)
Liebert XD Coolframe Module
Technical Data
Nominal Capacity, 60 Hz
Nominal Capacity, 50 Hz
Nominal Airflow, 60 Hz
8 kW / 2.2 Ton
6.5 kW / 1.85 Ton
1000 CFM (1700 m3/h)
Nominal Airflow, 50 Hz
Input Voltage
Full load amps (with optional
Condensate Detection)
Height (unit only)
Width
Depth
Weight, empty
Options
830 CFM (1410 m3/h)
120 V, 1 ph, 60 Hz or 230 V, 1 ph, 50/60 Hz
2A @ 120V, 1ph, 60 Hz
1A @ 230V, 1ph, 50 Hz
14” (355 mm)
23.5” (597 mm)
29.5”-39.5” (749-1003 mm)
77 lbs (35 kg)
Pre-charged flexible piping with threaded
couplings, with automatic shut off when
disconnected.
Condensate Detection (dry contacts)
Liebert XDO Overhead
Cooling Module
Technical Data
Technical Data
Nominal Capacity
Height
Width
Depth
Weight, empty
Flex-Pipe Length
Liebert XDV Top Mounted
Cooling Module
10 kW (2.8 tons)
30-1/4” (768mm)
12-1/4” (311mm)
6-1/2” (165mm)
18 lbs (8kg)
Top Module 6’ (1.8m)
Bottom Module 10’ (3m)
Nominal Capacity, 60 Hz
Nominal Capacity, 50 Hz
Nominal Airflow, 60Hz
Nominal Airflow, 50Hz
Input Voltage
Full load amps
Compatibility
Product
Model Number
Egenera BladeFrame EX
BC 100101, BC 100102
Liebert XD CoolFrame Module
XD-CF-10-XX
Liebert XDP
XDP160RXXXX
Liebert XDC
XDC160AXXXX
Liebert XD Field Piping Kits and Liebert XD Connection Port Kits
70
Height
Width
Depth
Weight
Options
16 kW / 4.5 Ton
14 kW / 4 Ton
2700 CFM (4590 m3/h)
2250 CFM (3820 m3/h)
120 V, 1 ph, 60 Hz
230 V, 1 ph, 60 Hz
200/230 V, 1 ph, 50 Hz
2.7A @ 120V, 1ph, 60 Hz
1.44A @ 230V, 1ph, 50 Hz
22.5” (572 mm)
72.0” (1829 mm)
24” (610 mm)
150 lbs (68 kg)
Condensate Detection (dry contacts)
Maximizing Your Investment Through Adaptive Monitoring
Distributed Management
with OpenComms
Interface Cards
Centralized Management
with OpenComms
Nform Software
Enterprise Management
with SiteScan Web
Software
For enhanced remote communications
As business grows your critical
For customers who require extensive
and control of your Liebert units, the
equipment infrastructure will expand,
management of critical system
OpenComms Web cards will deliver
thus the need for centralized
equipment that may span multiple
SNMP and web-management
management of this equipment will
locations in an ever-moving global
communications capabilities.
be key to your business success.
enterprise, SiteScan Web will centrally
Connecting to equipment in the
manage your critical equipment and
distributed critical space is only part
give you the power to move beyond
of the monitoring challenge.
the event responsive service paradigm.
Monitoring and control through
your existing Network with no
additional software required.
Liebert OpenComms Nform
SiteScan Web does it all —
leverages the network connectivity
I
Real-Time Monitoring and Control
capabilities of your Liebert equipment
I
Event Management and Reporting
to provide a centralized monitoring
I
Data Analysis and Trending
view of your distributed equipment.
I
Building Management Integration
operations center or wherever
Utilizing the SNMP and Web
Liebert SiteScan® Web is a
network access is permitted, without
technologies built into each of the
comprehensive critical systems
the need for front-end software.
OpenComms communication cards,
management solution dedicated to
OpenComms Nform will centrally
ensuring reliability through graphics,
Each Liebert system equipped with
an OpenComms Web card takes full
advantage of your Ethernet network,
allowing remote monitoring from your
computer desktop, network
The OpenComms Web cards support
10 and 100 MBit Ethernet network
transmissions speeds, which will be
auto-detected upon connection to
the network. Plus, these cards support
in-the-field firmware updates, which
increase the value of your investment.
manage alarm notifications to provide
event management and data
you with an easy interface to access
extrapolation. The standard Web
critical status information. OpenComms
interface allows users easy access
Nform puts critical systems information
from anywhere at anytime.
at the fingertips of support personnel —
I
wherever they are — increasing
I
responsiveness to alarm-event
I
conditions, thus allowing IT
organizations to maximize their
I
system availability.
I
I
OpenComms Web
Single- and multi-site applications.
Event management and unit control.
Trend and historical data captures
and reporting.
Full ASHRAE BACnet compatibility.
Java based.
Windows 2000, XP and 2003
compatible.
OpenComms Nform
Site Scan Web
71
Emerson Network Power, the global leader in enabling businesscritical continuity, ensures network resiliency and adaptability
through a family of technologies – including Liebert power and
cooling technologies as well as Knurr integrated cabinet solutions for business-critical continuity – that protect and support
business-critical systems. Liebert and Knurr solutions employ an
adaptive architecture that responds to changes in criticality, high
density and capacity. Enterprises benefit from greater IT system
availability, operational flexibility, and reduced capital equipment and operating costs.
Liebert Corporation
1050 Dearborn Drive
P.O. Box 29186
Columbus, Ohio 43229
800 877 9222 Phone (U.S. & Canada
only)
614 888 0246 Phone (Outside U.S)
614 841 6022 FAX
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco (PD)
Italy
39 049 9719 111
39 049 5841 257 FAX
Emerson Network Power Asia Pacific
7/F., Dah Sing Financial Centre
108 Gloucester Rd, Wanchai
Hong Kong
852 25722201 Phone
852 28029250 FAX
www.liebert.com
24 x 7 Tech Support
800 222 5877 Phone
614 841 6755 (Outside U.S.)
While every precaution has been taken to ensure
accuracy and completeness in this literature, Liebert
Corporation assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.
Knurr, Inc.
© 2006 Liebert Corporation. all rights reserved
throughout the world, Specifications subject to
change without notice.
20740 Plummer Street
Chatsworth, CA 91311
818 534 2840 Phone
818 534 2841 FAX
All names referred to are trademarks or registered
trademarks of their respective owners.
Knurr AG
Mariakirchener Strasse 38
94494 Arnstorf, Germany
+49 8723 270 Phone
+49 8723 27154 FAX
® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.
SL-11370(08/06) Printed in Germany
Emerson Network Power
The global leader in enabling Business-Critical Continuity™
AC Power Systems
Connectivity
DC Power Systems
Embedded Computing
Embedded Power
Integrated Cabinet Solutions
EmersonNetworkPower.com
Outside Plant
Power Switching & Control
Precision Cooling
Services
Site Monitoring
Surge Protection
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
©2006 Emerson Electric Co.