RCDE LED - INDUS Lighting

advertisement
FLOODLIGHTS FOR LED
LAMPS
Explosion Proof Electrical Equipment
RCDE LED
Installation: hazardous areas - Zone 1 / 2 (Gases) - Zone 21 / 22 (Dusts)
Classification: Group II - Category 2G 2D
FLOODLIGHT
ATEX 94/9/EC
EXECUTION
IEC Ex
II 2 G Ex db IIC T4
Ex db IIC T4
II 2 D Ex tb IIIC T135°C…T230 °C Ex tb IIIC T135°C…T230 °C
AMBIENT TEMP.
PROTECTION
DEGREE
CERTIFICATE REF.
RULES OF
COMPLIANCE
INMETRO
GOST-R (RTR/RTN)
GOST-K
Ex db IIC T4
Ex tb IIIC T135°C…T230 °C
1Ex d IIC T6 T4…T2X
Ex tD A21 T135…230°C
1Ex d IIC T6 T4…T2X
Ex tD A21 T135…230°C
-60°C ÷ +52°C
-60°C ÷ +52°C
-60°C ÷ +60°C
-60°C ÷ +60°C
-60°C ÷ +60°C
IP66
IP66
IP66
IP66
IP66
INERIS 03 ATEX 0004X
-
-
POCC IT. ME92.B02923
No. 07/43-269
EN 60079-0:2009;
EN 60079-1:2007;
EN 60079-7:2008;
EN 60079-31:2009
IEC 60079-0:2007;
IEC 60079-1:2007;
IEC 60079-31:2008
ABNT NBR IEC 60079-0:2007-10; ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р 51330.0/1/8/14-99;
ABNT NBR IEC 60079-1:2007-04; ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1-1-2002
ABNT NBR IEC 61242-31:2008-11 ГОСТ Р МЭК 61241-1:2004
CONTROL GEAR
ATEX 94/9/EC
EXECUTION
AMBIENT TEMP.
PROTECTION
DEGREE
CERTIFICATE REF.
RULES OF
COMPLIANCE
IEC Ex
II 2 G Ex d IIC T6÷T3 Gb
Ex d IIC T6÷T3 Gb
2 D Ex tb IIIC T85°C-T200°C Db Ex tb IIIC T85°C-T200°C Db
INMETRO
GOST-R (RTR/RTN)
GOST-K
Ex d IIC T6÷T3 Gb
Ex tb IIIC T85°C-T200°C Db
1Ex d IIC T6÷T3 X
DIP A21 TA (T85°C-T200°C)
1Ex d IIC T6÷T3 X
DIP A21 TA (T85°C-T200°C)
-60°C ÷ +60°C
-60°C ÷ +60°C
-60°C ÷ +60°C
-60°C ÷ +60°C
-60°C ÷ +60°C
IP66
IP66
IP66
IP66
IP66
INERIS 01 ATEX 0054X
-
-
POCC IT. ME92.B02923
No. 07/43-269
EN 60079-0:2009;
EN 60079-1:2007;
EN 60079-7:2008;
EN 60079-31:2009
IEC 60079-0:2007;
IEC 60079-1:2007;
IEC 60079-31:2008
ABNT NBR IEC 60079-0:2007-10;
ABNT NBR IEC 60079-1:2007-04;
ABNT NBR IEC 61242-31:2008-11
ГОСТ Р МЭК 60079-0:2011;
ГОСТ Р МЭК 61241-0:2007;
ГОСТ Р МЭК 61241-1:2004;
ГОСТ Р 51330.0/1/8/14-99;
ГОСТ Р МЭК 61241-1-1-2002
Mechanical characteristics
Body
marine grade copper free aluminium
Diffuser
tempered front glass
Support
adjustable type hot dip galvanized steel
Reflector
internal polished aluminium
Painting
external epoxy powders grey ral-9006 colour
Screws
external stainless steel
Gaskets
silicon rubber
Cable entry
3/4” npt size threaded
Electrical characteristics
Power supply
Internal wiring
336W 90÷305V ±10% - 50/60Hz - (cos ρ ≥ 0,93)
42 led by 8W(700mA) - luminous flux 700 mA 41000lm - led type “cold white”
Equivalent to 400W Hpna/Mh lamp
high-temperature resistant silicon rubber insulation cables
Terminals
suitable up to 4 sq/mm cables
Lamp type
On Request Accessories:
• External painting colour on request
• Control gear with voltage supply different than standard
• Threaded cable entry different than standard
Since 1961
YOUR PARTNER FOR SAFETY
Feam Catalogue 03 - 1
RCDE LED
Ex Lighting
Ex Lighting
CODE
TEMPERATURE CLASS
(GAS)
LAMP
TEMPERATURE CLASS
(DUSTS)
LAMP TYPE
CABLE ENTRY
SIZE
DETAIL
2 x 3/4”
A
FLOODLIGHTS FOR LED LAMP - POWER SUPPLY 120÷277V 50/60Hz
RCDE336LED
336 W T4 T135°C POWER LED
RCDE LED Technical features
CODE
A [mm]
RCDE336LED
B [mm]
C [mm]
D [mm]
WEIGHT [Kg]
370
406
700
29,00
535
CABLE ENTRY
2 x 3/4”
DETAIL
A
Reference details
A
1x3/4”
D
1x3/4”
A
B
RCDE LED
RCDE LED Technical data
C
220
RCDE LED Polar diagrams – photometric data
Luminaire
Code
RCDE-LED
Name
24SK00029-6n
Line
16_LED ALTA LUMINOSITA' - SFDE
Measurem.
Code 24SK00029
Name 24SK00029-6n
Date 13-09-2010
Lamp
Code
Number
Position
Efficiency
99.39%
Coordinate system
V-H
Total Flux
Maximum value
12354.00 cd/klm
Position
H=0.00 V=0.00
RCDE336LED
RCDE-LED
1
10558.00 lm
Asymmetric VH
VH Planes
H0.0
Flux: 10558.00 lm
H0
V0.0
Maximum: 12354.00 cd/klm
Position: H=0.00 V=0.00
V0
Efficiency: 99.39%
Double Symmetrical
VH Planes
Angles H
H Angles
180°
120°
3000
105°
105°
90°
90°
3000
75°
75°
6000
60°
60°
9000
45°
45°
12000
cd/klm
15000
30°
LITESTAR 10
15°
0°
(c)OxyTech Srl www.oxytech.it
15°
30°
Page 1
REMARK:
Due to the development of the national and international specifications and of the technology, the above technical characteristics
showed on this bulletin can be considered as binding on our confirmation only.
Since 1961
2 - Feam Catalogue 03
YOUR PARTNER FOR SAFETY
Download