Power/Vac® Vacuum Circuit Breakers CIRCUIT BREAKERS FOR 5KV-15KV APPLICATIONS USING THE ML-17 MECHANISM NEW STANDARDS The new Power/Vac series of circuit breakers have been tested to the latest ANSI C37.06-2009 standard. They are UL listed, and KEMA certified test reports are available. This latest design is based on the proven ML-17 mechanism, which has been in use for more than 35 years. The reliability of Power/Vac has been demonstrated by its ability to handle 63kA high interrupting duty for nearly 20 years. Adding to our flexibility of design, all breaker ratings are now available with 5 cycle or 3 cycle interrupting times. Class C2 (formerly classified as definite purpose) capacitor switching capability is also now available, which incorporates faster TRV values than in previous edition of the ANSI standards. POWER/VAC® CIRCUIT BREAKER FEATURES Enhanced ML-17 operating mechanism for more rugged operation. 20kA thru 63kA Utilizes the latest in vacuum interrupter technology which eliminates the need for surge suppressors All breakers now rated for K Factor = 1 All ratings now available with 5 cycle or optional 3 cycle interrupting time Now available with Class C2 capacitor switching rating • All vacuum interrupters now use the latest copper chromium technology which minimizes current chop. Surge suppressors are no longer required. • All Power/Vac breakers are now rated K Factor=1 • All Power/Vac breakers now use the more robust ML-17 or ML-17H operating mechanism. • The ML-17 mechanism is used for both circuit breakers and ground & test devices, which means reduced maintenance costs, fewer spare parts requirements, and reduced operator training. • Breakers can be easily retrofitted into existing lineups where older ML-18 breakers and/or MVA rated breakers were originally supplied. Powered by Safety® Circuit Breaker Characteristics Rated Withstand Test Voltages Rated Maximum Voltage (kV)1 Nominal ANSI Voltage Class (kV) Typical System Operating Voltages (kV) 4.16 2400 4160 4200 4.76 8.25 15 7.2 13.8 6600 6900 7200 12000 12470 13200 13800 14400 Rated Voltage Range Factor, K 1.0 1.0 1.0 Low Frequency rms Voltage (kV) 19 36 36 Crest Impulse Voltage (kV) 60 95 95 Continuous rms Current Rating at 60 Hz (Amperes)2 Rated Short Circuit Current (Maximum Interrupting Capability) (kA) 3 Rated Interrupting Time (cycles) Rated Permissible Tripping Delay, Y (Seconds) Maximum 2 Second Short Time Current Carrying Capability (kA) Peak Close and Latch (2.7K times Short Circuit Rating) (kA) 1200A 2000A 3000A 3500A 4000A 31.5 5 or 3 31.5 85 40 5 or 3 40 108 50 5 or 3 50 135 63 5 or 3 63 170 1200A 2000A 3000A 3500A 4000A 40 5 or 3 40 108 504 5 or 3 50 135 634 5 or 3 63 170 1200A 2000A 3000A 3500A 4000A 2 2 20 5 or 3 20 54 25 5 or 3 25 68 31.5 5 or 3 40 5 or 3 31.5 85 40 108 50 63 5 or 3 50 135 5 or 3 63 170 2 Notes: 1 Maximum voltage for which the breaker is designed and upper limit of operation 2 4000A rating is forced-air cooled, indoor construction only. 3500A is available in outdoor construction, but must be derated to 3250A. 3 At system operating voltages equal to or less than rated maximum voltage. 4 Available ratings in addition to the ANSI C37.06-2009 preferred ratings. Powered by Safety® Publication No. 06094 Powell Electrical Systems, Inc. 8550 Mosley Road Houston, Texas 77075 713.944.6900 Powell Canada Inc. 53032 Range Road 263A Acheson, Alberta T7X 5A5 780.948.3300 Powell (UK) Ltd. Ripley Road Bradford, West Yorkshire BD4 7EH +44.(0).1274.734221 10/2015 v3 powellind.com info@powellind.com ©2014 Powell Industries, Inc. All rights reserved.