Bench Multimeters

advertisement
1609-2014_QuarkCatalogTempNew 9/8/14 12:02 PM Page 1609
19
Bench Multimeters
AUTOMATION
& CONTROL
Fluke 8845A/8846A 6.5-Digit
Precision Multimeters
The Fluke 8845A and 8846A, 6.5 digit precision multimeters have the precision and versatility to handle your most
demanding measurements on the bench or in a system.
Dual Display Offers Versatile Graphical Capabilities: The 8845A and 8846A features a unique graphical display that can
reveal signal quality issues like drift, intermittent and stability by viewing the measurement data as a real time TrendPlot™,
Histogram or Statistics using the unique analyze mode.
ENCLOSURES
Wide Measurement Ranges: Resistance or current has been extended to cover the widest range possible. The 8846A
resistance measurements range is extended from 10 Ω up to 1 GΩ with a resolution of up to 10 µΩ. For DC current
measurements, the 8845A and 8846A ranges from 100 µA to 10 A with a maximum resolution of 100 pA.
Perform 4-Wire Measurements Easily with Two Leads: Patented split terminal jacks for 2 × 4 Ohms function allow you to
perform precise 4-wire measurements with only two leads instead of four. Optional Kelvin leads accessories are available to
enable you to establish a 4-wire connection even in tight spaces.
8845A
Fluke 8846A Extended Performance and Capabilities: The 8846A increases basic VDC accuracy to 0.0024% plus adds
measurements like capacitance, RTD temperature and dBm. The 8846A also includes a USB device port to connect standard
USB memory storage devices. USB memory is a convenient way to store or transfer critical data to your PC.
0.0035%
0.0024%
1000 V
750 V
100 Ω to 100 MΩ
1000 V
10 Ω to 1 GΩ
100 µA to 10 A
10 mA to 10 A
3 Hz-300 kHz
10 µA to 10 A
3 Hz-1 MHz
Yes
—
—
1 nF-0.1 F
–200 °F-600 °F
Statistics, Histogram, TrendPlot™, Limit Compare
NULL, Min/Max
NULL, Min/Max, dB/dBm
—
—
USB Memory Drive Port
Yes
RS232, IEEE-488.2, Ethernet
SCPI (IEEE-488.2), Agilent 34401A, Fluke 45, Fluke 8840/42
3.6 kg (8.0 Lbs.)
8.46" (215 mm) W, 3.46" (88 mm) H, 11.53" (293 mm) D
Designed to comply with IEC 61010-12000-1, ANSI/ISA-S82.01-1994,
CAN/CSA-C22.2 No.1010.1-92, 1000 V CAT I/600 V CAT II
3 Years
8846A
6.5-Digit Resolution
Graphical Display
Basic VDC Accuracy of Up to 0.0024%
100 µA to 10 A Current
10 Ohm to 1 GΩ Resistance
2 × 4 Wire Ohms Measurement Technique
Frequency, Period, Capacitance and RTD Temperature Measurements
Analytical Modes; TrendPlot™, Histogram and Statistics
USB Device Port for Memory Storage Devices
RS-232, IEEE-488 and Lan Interfaces
RS-232 to USB Adaptor Cable Included
Popular DMM Emulation Modes
Recommended Accessories: TL75 Test Lead Set, FVF-UG FlukeView Forms Upgrade
Fluke 8845A/8846A 6.5 Digit Precision Multimeters Series
Stock
No.
Mfr.’s
Type
EACH
70145659
70145658
8845A
8846A
1065.00
1495.00
Stock
No.
Mfr.’s
Type
EACH
70145833
8808A
810.00
OPTOELECTRONICS
Fluke 8808A
5.5-Digit Multimeter
PASSIVE & ACTIVE
Warranty
8846A
6.5 Digits
TEST & MEASUREMENT
Safety
8845A
INTERCONNECT
Mfr.’s Type
Resolution
Measurement Function
Basic VDC Accuracy
VDC
VAC
Resistance (2 × 4 Wire Ohms)
ADC
AAC
Freq/Period
Continuity/Diode Test
Capacitance
Temperature RTD
Advanced Functions
Analytical Functions
Mathematical Functions
Input Output
USB Device Port
Real Time Clock
Interfaces
Programming Languages/
Emulation Modes
General
Weight
Size
POWER
Systems Capabilities: Both instruments include an RS-232, IEEE-488 and Ethernet interface as standard, with popular DMM
emulation modes make systems integration a simple task.
Manufacturing test, R&D, development and service applications demand performance and flexibility from a bench meter.
The Fluke 8808A delivers a wide variety of measurement functions, including volts, ohms and amps, plus frequency —
all at superior accuracy and resolution with a basic VDC accuracy of 0.015%.
Measure Sensitive Leakage Current: The Fluke 8808A is the only multimeter in its class to use a high impedance input
technique to perform this type of critical leakage current measurement. In this special mode, the 8808A can measure small
currents with a resolution of up to 100 nA, without loading the circuit under test.
ASSEMBLY
Perform Routine Manufacturing Functional Tests with Consistency: Set up the meter for a common measurement, then
press shift followed by a setup button (S1 to S6) to save the setup. Now each time you perform that measurement, simply
press the appropriate setup key. Operators no longer need to press multiple buttons to make a measurement.
Eliminate Production Mistakes: Whether you are performing functional tests or making critical measurements on test points,
using the limit compare mode with pass/fail indicators eliminates mistakes, especially those where results are “on the edge.”
Perform 4-Wire Measurements with Only Two Leads: Patented split terminal jacks for 2 × 4 Ohms function allows to
perform precise 4-wire low ohms measurements with only two leads instead of four. Optional test lead accessories are
available to establish a 4-wire connection even in tight spaces or on surface mount devices.
5.5-Digit Resolution
Dual Display
Measures VDC/VAC, I DC/AC, Ω, Freq, Continuity, Diode
Basic VDC Accuracy of Up to 0.015%
Min, Max, Rel, dB, dBm
2 × 4 Wire Ohms Measurement Technique
Dedicated DC Leakage Current Ranges
Six Dedicated Buttons for Fast Access to Instrument Setups
Hi/Lo Limit Compare for Pass/Fail Testing
RS-232 Interface
RS-232 to USB Adaptor Cable Included
Recommended Accessories: TL81A Deluxe Test Lead Set, FVF-UG FlukeView Forms Upgrade
INDEX
Fluke 8808A
TEST & MEASUREMENT 1609
19
Download